Search NASA⌕ Search

SEARCH · Search NASA

Results for “microscope”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 991 records · Page 55

Scanning probe microscope simulator for the assessment of noise in scanning probe microscopy controllers

We present an electronic circuit that allows to calibrate and troubleshoot scanning probe microscopy (SPM) controllers with respect to their noise performance. The control signal in an SPM is typically highly nonlinear—the tunneling current in scanning tunneling microscopy (STM) varies exponentially with distance. The exponential current-versus-voltage characteristics of diodes allow to model the current dependence in STM. Additional inputs allow to simulate the effects of external perturbations and the reactions of the control electronics. We characterized the noise performance of the feedback controller using the apparent topography roughness of recorded images. For a comparison of different STM controllers, an optimal gain parameter was determined by exploring settling times through a rectangular perturbation signal. We used the circuit to directly compare the performance of two types of SPM controllers used in our laboratory.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Luminescence of Quantum Dots by Coupling with Nonradiative Surface Plasmon Modes in a Scanning Tunneling Microscope

The electronic coupling between quantum dots (QDs) and surface plasmons (SPs) is investigated by a luminescence spectroscopy based on scanning tunneling microscopy (STM). We show that tunneling luminescence from the dot is excited by coupling with the nonradiative plasmon mode oscillating at the metallic tunneling gap formed during the STM operation. This approach to the SP excitation reveals aspects of the SP-QD coupling not accessible to the more conventional optical excitation of SPs. In the STM, luminescence from the dot is observed when and only when the SP is in resonance with the fundamental transition of the dot. The tunneling luminescence spectrum also suggests that excited SP-QD hybrid states can participate in the excitation of QD luminescence. Not only the SP excitation regulates the QD luminescence but the presence of the dot at the tunneling gap imposes restrictions to the SP that can be excited in the STM, in which the SP cannot exceed the energy of the fundamental transition of the dot. The superior SP-QD coupling observed in the STM is due to the tunneling gap acting as a tunable plasmonic resonator in which the dot is fully immersed.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Microscope of glassy relaxation in femtogram samples: Charge offset drift in the single electron transistor

By measuring the long-term charge offset drift in single electron tunneling transistors, we have observed a transient relaxation after fabrication which is correlated with the presence of amorphous insulator. The temperature and time dependence of the transient relaxation are both in agreement with an extension of the standard model for two-level systems in glasses. This technique, which is sensitive to atomic scale motion in femtogram-sized samples, offers the possibility of a technique for investigation of glassy relaxation.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Nanoscale Proximity Effect in the High-Temperature Superconductor Bi2Sr2CaCu2O8+δ Using a Scanning Tunneling Microscope

High-temperature cuprate superconductors exhibit extremely local nanoscale phenomena and strong sensitivity to doping. While other experiments have looked at nanoscale interfaces between layers of different dopings, we focus on the interplay between naturally inhomogeneous nanoscale regions. Using scanning tunneling microscopy to carefully track the same region of the sample as a function of temperature, we show that regions with weak superconductivity can persist to elevated temperatures if bordered by regions of strong superconductivity. This suggests that it may be possible to increase the maximum possible transition temperature by controlling the distribution of dopants.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

The Probe Length Effect on the Cantilever of an Atomic Force Microscope in Measuring the Mechanical Properties of Living Neurons

Living sensory neurons were studied by atomic force microscopy in the PeakForce QNM mode under near-physiological conditions. The dependence of the measured apparent Young modulus of cells on the ratio of the probe height to the beam length on a used cantilever was revealed. A qualitative explanation based on the analysis of beam strains in two limit cases, in which the probe slides over a studied object and the probe sticks to the latter, was given to the obtained result. It was proposed to classify native cells by the character of their interaction with the probe (sliding or sticking).

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Real-time Studies of Battery Electrochemical Reactions Inside a Transmission Electron Microscope

We report the development of new experimental capabilities and ab initio modeling for real-time studies of Li-ion battery electrochemical reactions. We developed three capabilities for in-situ transmission electron microscopy (TEM) studies: a capability that uses a nanomanipulator inside the TEM to assemble electrochemical cells with ionic liquid or solid state electrolytes, a capability that uses on-chip assembly of battery components on to TEM-compatible multi-electrode arrays, and a capability that uses a TEM-compatible sealed electrochemical cell that we developed for performing in-situ TEM using volatile battery electrolytes. These capabilities were used to understand lithiation mechanisms in nanoscale battery materials, including SnO 2 , Si, Ge, Al, ZnO, and MnO 2 . The modeling approaches used ab initio molecular dynamics to understand early stages of ethylene carbonate reduction on lithiated-graphite and lithium surfaces and constrained density functional theory to understand ethylene carbonate reduction on passivated electrode surfaces.

25 ENERGY STORAGE↗

Electron optics for 4 MeV ultrafast electron microscope - Final Report

Calabazas Creek Research, Inc. (CCR), in collaboration with Northern Illinois University (NIU), proposed to leverage CCR’s experience in electron beam generation and focusing and NIU’s experience in electron microscopy to develop a 4 MeV UEM with sub-ns temporal resolution and 0.3 nm spatial resolution with a relative energy spread of 10-5. Important design tools for the program were CCR’s 3D, finite element code Beam Optics Analyzer (BOA) and the photocathode design code PHOTOQE. However, early in the program it became clear that information necessary to use PHOTOQE was not available, and the program focused on the modifying to BOA to provide the required functionality.

beam optics simulation↗

Transmission electron microscope (TEM), BBOP

These transmission electron microscopy (TEM) images indicate representative particle shapes and mixing states collected during the BBOP campaign. Aerosol particles were collected onto lacey-carbon substrates.

54 ENVIRONMENTAL SCIENCES↗

DeepFocus Acoustic Microscope Transducer

A new nondestructive testing device being used to analyse nuclear fuel could reduce costs for manufacturing and other industry. For more information about INL research projects, visit http://www.facebook.com/idahonationallaboratory.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Detecting anthrax in the palm of your hand: applications of a smartphone microscope

Bacillus anthracis is a bacterial pathogen that causes the disease anthrax. In 2001, B. anthracis was used in a bioterrorism attack in the United States that resulted in 22 individuals becoming infected, 5 of whom died as a result of this attack. A great deal of attention has been dedicated to responding to bioterrorism events to reduce the potential loss of lives. One such area of research has focused on the development of new technologies to detect and respond to the intentional release of bacterial pathogens such as B. anthracis.

B. anthracis, anthrax, smartphone microscope, fluo↗

Scanning Probe Microscope to Map Thermal and Thermoelectric Properties of Combinatorial Materials

The combinatorial methodology offers a high-throughput process for developing radiation-resistant sensor materials for nuclear energy applications through the synthesis and screening of large numbers of compositions and processing conditions in a single process. The combinatorial materials fabrication coupled with an automated screening process enables us to identify the optimal materials composition and processing conditions that yield both desired properties and required irradiation resistance in the most efficient and economic manner. The report focuses on the development of scanning probe technique to map with high resolution the thermal conductivity, Seebeck coefficient and electrical conductivity of combinatory materials with gradient compositions, which has been a key challenge in combinatory materials science. The above three properties play important roles in many sensor materials for nuclear energy applications.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗