Search NASA⌕ Search

SEARCH · Search NASA

Results for “performance data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 991 records · Page 55

Imminent: Irradiation Testing of (Th,Pu)O{sub 2} Fuel - 13560

Commercial-prototype thorium-plutonium oxide (Th-MOX) fuel pellets have been loaded into the material test reactor in Halden, Norway. The fuel is being operated at full power - with instrumentation - in simulated LWR / PHWR conditions and its behaviour is measured 'on-line' as it operates to high burn-up. This is a vital test on the commercialization pathway for this robust new thoria-based fuel. The performance data that is collected will support a fuel modeling effort to support its safety qualification. Several different samples of Th-MOX fuel will be tested, thereby collecting information on ceramic behaviours and their microstructure dependency. The fuel-cycle reasoning underpinning the test campaign is that commercial Th- MOX fuels are an achievable intermediate / near-term SNF management strategy that integrates well with a fast reactor future. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Solar-Powered Air Stripping at the Rocky Flats Site, Colorado - 12361

The U.S. Department of Energy's Rocky Flats Site (the Site), near Denver, Colorado, is a former nuclear weapons facility that was constructed beginning in 1951. With the end of the Cold War, the Site was cleaned up and closed in 2005. Four gravity-driven groundwater treatment systems were installed during cleanup, and their continued operation was incorporated into the final remedy for the Site. All utilities, including electrical power, were removed as part of this closure, so all Site electrical power needs are now met with small solar-powered systems. The Mound Site Plume Treatment System (MSPTS) was installed in 1998 as an innovative system based on zero-valent iron (ZVI). Groundwater flow from the Mound source area containing elevated concentrations of volatile organic compounds (VOCs), primarily in the tetrachloroethene (PCE)-trichloroethene (TCE) family of chlorinated solvents, is intercepted by a collection trench and routed to twin ZVI treatment cells. Later, in 2005, remediation of VOC-contaminated soils at a second up-gradient source area included adding an electron donor to the backfill to help stimulate biodegradation. This reduced concentrations of primary constituents but caused down-gradient groundwater to contain elevated levels of recalcitrant degradation byproducts, particularly cis-1,2-dichloroethene and vinyl chloride. A gravel drain installed as part of the 2005 remediation directs contaminated groundwater from this second source area to the MSPTS for treatment. This additional contaminant load, coupled with correspondingly reduced residence time within the ZVI media due to the increased flow rate, resulted in reduced treatment effectiveness. Elevated concentrations of VOCs were then detected in MSPTS effluent, as well as in surface water at the downstream performance monitoring location for the MSPTS. Subsequent consultations with the Site regulators led to the decision to add a polishing component to reduce residual VOCs in MSPTS effluent. Initially, several alternatives such as commercial air strippers and cascade aerators were evaluated; resulting cost estimates exceeded $100,000. After several simpler alternatives were considered and prototype testing was conducted, the existing effluent metering manhole was converted to house a spray-nozzle based, solar-powered air stripper, at a cost of approximately $20,000. About two-thirds of this cost was for the solar power system, which was initially designed to only provide power for 12 hours per day. Performance data are being collected and adjustments made to optimize the design, determine maintenance requirements, and establish power needs for continuous operation. Analytical data confirm the air stripper is sharply reducing concentrations of residual contaminants. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Investigation of Wind Plant Wake Effects at the AWAKEN Field Campaign

Wind plant wakes characterized by lower momentum flow with increased turbulent kinetic energy (TKE) have been shown to propagate for several kilometers and interact with neighboring plants. To better understand these interactions, an Oklahoma site hosting five wind plants is heavily instrumented as part of the American Wake Experiment (AWAKEN) field campaign. Upstream, interior-plant, and downstream flows are probed using a suite of remote sensing instruments to quantify wake properties such as the magnitude and extent of momentum deficit and TKE increase. The effects of atmospheric inflow (wind speed, turbulence, stability, etc.) are investigated. Under certain conditions, the impact of an upstream plant on its downstream neighbor can be observed using the performance data recorded by the downstream plant. In addition to providing insight into plant wake behavior, the results of this study will be used as a benchmark case for wind plant simulations.

AWAKEN↗

Decarbonization of Liquid Heating Fuels

Annually, residential and commercial buildings use about 5 billion gallons (18.9 billion liters) of distillate fuel for space and water heating. There is considerable interest in decarbonizing these markets through a combination of heat pumps and a future, carbon-free grid. An alternate approach that offers rapid and cost effective decarbonization involves substitution of low-carbon biofuels for fossil fuels within this market. Heating fuel marketers in North America and Europe are aggressively moving to achieve market penetration of biofuels. Processes for this include fuel specification standards, development of manufacturer-approved burners and all system components, development of standards for equipment listing, installation code changes, and generation of performance data. There has been considerable progress in these areas and each of these are reviewed in this paper. Currently, the most important biofuel for this market is biodiesel with a U.S. production capacity of 2.4 billion gallons (9.1 billion liters) and approximately a 75% reduction in GHG emissions. The biodiesel industry has stated a vision for dramatic increases in biodiesel production over the next decades. Fuel and equipment standards are in place to enable use of biodiesel blends to 20% and this blend is now widely used. Standard changes to extend this to as high as 100% biodiesel are nearing completion. Several states have implemented requirements for minimum levels of biodiesel in heating oil with these levels increasing over time.

09 BIOMASS FUELS↗

Thermal Model for Horizontal In-Water and In-Air Mini-Plate Experiments in the Advanced Test Reactor

Mini-Plate (MP) irradiation tests are a fueled experiment designed for irradiation in multiple test locations in the Advanced Test Reactor (ATR) at the Idaho National Laboratory (INL). MP experiments are considered a non-instrumented drop-in test where small aluminum-clad fuel plate samples are cooled directly by the ATR Primary Coolant System (PCS) water. These fueled experiments contain aluminum-clad fuel mini plates consisting of monolithic U-10Mo. Previous thermal analyses have been documented concerning oxide growth[1] and thermal safety margin[2] for the MP-2 experiment. A thermal analysis has been performed on the MP-2 experiment using a new technique for calculating the necessary time after the experiment has been irradiated and reactor shutdown necessary to not exceed the 95% lower bound blister threshold temperature for the fuel in a horizontal in air configuration. A horizontal in water model has also been analyzed and will be discussed. After the experiment is irradiated in the ATR, it is necessary to calculate the fuel meat temperatures at 12 hours after shutdown. This is done to assure that at the 12 hour mark, if this experiment is removed from the reactor and accidentally dropped onto the working tray and is in the most severe geometrical configuration of horizontal (minimum heat transfer) that fission products will not be released. The blister threshold temperature is considered this safety limit. The horizontal in air analysis is also performed considering that the experiment is horizontal in a drained canal and filled with air and natural convection heat transfer with air on the outside. The initial mini-plate testing campaign known as MP-1 [3] has been irradiated and its purpose was to form the base fuel specimens fabricated by various processes so that a single process can be down-selected for qualification. MP-2 will then serve to populate a comprehensive fuel performance data set for the down-selected fabrication process. The MP-2 experiment will be irradiated in several locations of the ATR as shown in Figure 1. The fuel plate thickness and geometry is identical to the MP-1 experiment [3], with the only variable being the fuel meat thickness. This model of the B-12 position is treated as encompassing the I-21, I-24, and B-9 positions since it has more fuel and higher total heat than the other positions. Since the blister threshold temperature is a function of fission density, a series of fission densities is calculated for the B-12 position to cover the other three positions. The B 12 position specifically uses fuel meat that is 0.016 in thick by 3.25 in long and 0.75 in tall. The total plate thickness is 0.050 in. Aluminum cladding forms the barrier between the PCS and the fuel meat. The purpose of this paper is to demonstrate this new technique developed to calculate the necessary decay time after shutdown for a series of fission densities using the ABAQUS [4] finite element and heat transfer code.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Techno-Economic Analysis of Geologically Connected Seawater Air Conditioning (GeoSWAC) Concept for District Cooling at the University of Puerto Rico at Rio Piedras: Preprint

At the University of Puerto Rico at Rio Piedras, a central chilled water plant supplies cooling to several campus buildings, contributing significantly to electricity demand during daytime peak hours, particularly in the summer months. These operational challenges are exacerbated by Puerto Rico's tropical rainforest climate and a power grid vulnerable to frequent disruptions caused by hurricanes and tropical storms. This study presents a techno-economic analysis of the existing chilled water plant serving four representative campus buildings and introduces a conceptual alternative: the Geologically connected Seawater Air Conditioning (GeoSWAC) system. GeoSWAC leverages stable low temperatures of deep ocean water (~1 km depth), hydraulically connected to an inland well, to deliver cooling without the use of vapor-compression refrigeration. Using modeled annual cooling loads and chiller performance data, capital costs, energy consumption, and levelized cost of cooling (LCOC) were evaluated for both systems. While GeoSWAC showed higher capital costs than the chiller-based scenario, operational costs were significantly lower at $26k-$53k annually, resulting in a lower LCOC between $2.3/MWh and $8.2/MWh compared to $30.2/MWh-$33.6/MWh for the chiller scenario. These results suggest that the GeoSWAC system offers a promising, low-energy, and climate-resilient alternative for large-scale cooling in tropical coastal environments, with significant potential to reduce peak electricity demand and improve long-term system reliability.

15 GEOTHERMAL ENERGY↗

The Department of Energy and IDEA team up to document industry best practices

This article describes a collaboration between the U.S. Department of Energy and the International District Energy Association (IDEA) to document best practices in district energy systems. The initiative focuses on analyzing real-world performance data and highlighting effective strategies for improving efficiency, integrating renewable energy, and supporting decarbonization efforts. It highlights case studies from the University of California, Davis, and Princeton University to show how long-term master planning, phased project implementation, and strong financial analysis can drive successful transitions to more sustainable energy systems. U.C. Davis emphasizes incremental, results-driven planning and pilot projects, while Princeton focuses on aligning climate goals with financially viable infrastructure investments and life-cycle cost analysis. Overall, the article demonstrates that combining strategic planning, data-driven decision-making, and financial accountability is essential for advancing sustainable district energy systems.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

Database Performance Monitoring for DUNE

This report presents the research, design, and implementation of improved PostgreSQL monitoring for DUNE Rucio database services using Checkmk. The project began with a request to improve dashboard visibility for database performance metrics, including connection usage, configured connection limits, lock activity, wait behavior, storage trends, query performance, and saturation alerts. The initial implementation focused on the dune_rucio_prod database on the rucio_prod PostgreSQL instance because connection saturation and lock contention are direct reliability risks for database-backed services. Existing Checkmk PostgreSQL monitoring was investigated, and several gaps were identified. Built-in connection monitoring did not clearly separate active, idle, idle-in-transaction, total, and usage-percent metrics, while the built-in lock monitoring simplified PostgreSQL lock modes into shared and exclusive categories. To address these gaps, two DSG-specific Checkmk local checks were created: one for connection-state monitoring and one for lock-state monitoring. These checks supplement the built-in PostgreSQL checks and provide additional performance data for dashboard graphs, service states, and alerts.

Bowers, Elliot [Cabrillo Coll.]↗

AFC-1 Fuel Rodlet Fission Power Deposition Validation in ATR

One of the viable options of long-term geological disposal of the nuclear power reactors generated spent fuel is to extract plutonium, the minor actinides (MA) and potentially long-lived fission products from the spent fuel and transmute them into short-lived or stable radionuclides in an appropriate reactor for the reduction of the radiological toxicity of the nuclear waste stream. An important component of that technology will be a non-fertile / low-fertile actinide transmutation fuel form containing the plutonium, neptunium, americium (and possibly curium) isotopes to be transmuted. Such advanced fuel forms, especially ones enriched in the long-life minor actinide (LLMA) elements (i.e., Np, Am, Cm), have minimal irradiation performance data available from which to establish a transmutation fuel form design. Recognizing these needs, an Advanced Fuel Cycle test series-1 (AFC-1) irradiation test on a variety of candidate fuel forms is now being conducted in Advanced Test Reactor (ATR) at the Idaho National Laboratory (INL). The first advanced fuel experiment (AFC-1) has been finalized and the test assembly analyzed for insertion and irradiation in ATR. The ATR core consists of a serpentine and rotationally symmetric fuel assembly about the z-axis of the core center. The plan view of the ATR core configuration is shown in Fig. 5, in Ref. 1. A cadmium filter with a 0.178 cm (0.045") thickness and 121.5 cm (48") in length, is currently used in the actinide-fuel capsule design for the East Flux Trap (EFT) position in ATR, to depress the linear heat generation rate (LHGR) lower than the project’s 330 W/cm limit for the experimental fuel rodlets. The LHGR is proportional to the fission power deposited in the fuel rodlets from the neutron fissions. The fraction of the fission power generated from the neutron fission reactions deposited in the fuel rodlet is an important parameter for test assembly thermal analysis, which will be validated in this summary.

99 GENERAL AND MISCELLANEOUS↗

The CO2 Reduction Potential of Combined Heat and Power in California's Commercial Buildings

The Ernest Orlando Lawrence Berkeley National Laboratory (LBNL) is working with the California Energy Commission (CEC) to determine the potential role of commercial sector distributed generation (DG) with combined heat and power (CHP) capability deployment in greenhouse gas emissions (GHG) reductions. CHP applications at large industrial sites are well known, and a large share of their potential has already been harvested. In contrast, relatively little attention has been paid to the potential of medium-sized commercial buildings, i.e., ones with peak electric loads ranging from 100 kW to 5 MW. We examine how this sector might implement DG with CHP in cost minimizing microgrids that are able to adopt and operate various energy technologies, such as solar photovoltaics (PV), on-site thermal generation, heat exchangers, solar thermal collectors, absorption chillers, and storage systems. We apply a mixed-integer linear program (MILP) that minimizes a site's annual energy costs as its objective. Using 138 representative mid-sized commercial sites in California (CA), existing tariffs of three major electricity distribution ultilities plus a natural gas company, and performance data of available technology in 2020, we find the GHG reduction potential for this CA commercial sector segment, which represents about 35percent of total statewide commercial sector sales. Under the assumptions made, in a reference case, this segment is estimated to be capable of economically installing 1.4 GW of CHP, 35percent of the California Air Resources Board (CARB) statewide 4 GW goal for total incremental CHP deployment by 2020. However, because CARB's assumed utilization is far higherthan is found by the MILP, the adopted CHP only contributes 19percent of the CO2 target. Several sensitivity runs were completed. One applies a simple feed-in tariff similar to net metering, and another includes a generous self-generation incentive program (SGIP) subsidy for fuel cells. The feed-in tariff proves ineffective at stimulating CHP deployment, while the SGIP buy down is more powerful. The attractiveness of CHP varies widely by climate zone and service territory, but in general, hotter inland areas and San Diego are the more attractive regions because high cooling loads achieve higher equipment utilization. Additionally, large office buildings are surprisingly good hosts for CHP, so large office buildings in San Diego and hotter urban centers emerge as promising target hosts. Overall the effect on CO2 emissions is limited, never exceeding 27percent of the CARB target. Nonetheless, results suggest that the CO2 emissions abatement potential of CHP in mid-sized CA buildings is significant, and much more promising than is typically assumed.

03 NATURAL GAS↗

Performance analysis of data intensive cloud systems based on data management and replication: a survey

As we delve deeper into the ‘Digital Age’, we witness an explosive growth in the volume, velocity, and variety of the data available on the Internet. For example, in 2012 about 2.5 quintillion bytes of data was created on a daily basis that originated from myriad of sources and applications including mobiledevices, sensors, individual archives, social networks, Internet of Things, enterprises, cameras, software logs, etc. Such ‘Data Explosions’ has led to one of the most challenging research issues of the current Information and Communication Technology era: how to optimally manage (e.g., store, replicated, filter, and the like) such large amount of data and identify new ways to analyze large amounts of data for unlocking information. It is clear that such large data streams cannot be managed by setting up on-premises enterprise database systems as it leads to a large up-front cost in buying and administering the hardware and software systems. Therefore, next generation data management systems must be deployed on cloud. The cloud computing paradigm provides scalable and elastic resources, such as data and services accessible over the Internet Every Cloud Service Provider must assure that data is efficiently processed and distributed in a way that does not compromise end-users’ Quality of Service (QoS) in terms of data availability, data search delay, data analysis delay, and the like. In the aforementioned perspective, data replication is used in the cloud for improving the performance (e.g., read and write delay) of applications that access data. Through replication a data intensive application or system can achieve high availability, better fault tolerance, and data recovery. In this paper, we survey data management and replication approaches (from 2007 to 2011) that are developed by both industrial and research communities. The focus of the survey is to discuss and characterize the existing approaches of data replication and management that tackle the resource usage and QoS provisioning with different levels of efficiencies. Moreover, the breakdown of both influential expressions (data replication and management) to provide different QoS attributes is deliberated. Furthermore, the performance advantages and disadvantages of data replication and management approaches in the cloud computing environments are analyzed. Open issues and future challenges related to data consistency, scalability, load balancing, processing and placement are also reported.

Malik, Saif Ur Rehman↗

Policy, Permit, Perform: Using City Benchmarking Data and Building Construction Permit History to Identify Energy Performance Improvements

The City of Portland (City) and Multnomah County 2015 Climate Action Plan targets a 40 percent reduction in carbon emissions below 1990 levels by 2030. To reach this goal, the plan includes a key objective to reduce the total energy use of existing buildings by 25 percent. Buildings are responsible for one-half of carbon emissions in Portland, Oregon, U.S., and improving their performance is critical to achieving the City’s climate goals. As part of its climate action planning, the City passed an ordinance on April 22, 2015, requiring commercial buildings 20,000 ft2 and larger to benchmark and disclose annual energy performance metrics through ENERGY STAR® Portfolio Manager® (ESPM), including greenhouse gas emissions, building energy use intensity (EUI) and ENERGY STAR scores. Twenty-five cities in the U.S. have adopted similar policies requiring energy benchmarking. These policies are generating a treasure trove of data about the drivers of building performance, but practitioners are only beginning to link benchmarking data to other datasets to produce actionable insight into improving building performance. In 2016, the City received a financial assistance award from the U.S. Department of Energy (DOE) through the Cities Leading through Energy Analysis and Planning project (Award Number DE-0007737). Portland’s project evaluated the application of the DOE Building Energy Asset Score Tool and rating system developed by Pacific Northwest National Laboratory (PNNL) to commercial buildings that report to the City. The City used building construction permit history to develop Asset Scores for a set of office buildings that reported energy performance for 2015 – the first year the City mandated energy benchmarking and reporting for commercial buildings 50,000 ft2 and larger. The primary project objective was to link energy benchmarking data and commercial building permit data to analyze commercial buildings systems that present the best, specific opportunities to improve energy performance. Integrating these datasets from two City departments, the Bureau of Development Services and the Bureau of Planning and Sustainability, could expand Portland’s use of analytics to inform climate policy decisions and strategic targeting of financial incentives for building owners and managers who are best positioned to improve the performance of their buildings. The project began with the commercial benchmarking data received for 340 commercial buildings that submitted calendar year 2015 energy reports. The City retained Research Into Action and Energy 350 (RIA team) to evaluate this self-reported benchmarking data. Based on a survey of 53 building managers, the RIA team found that most respondents used the City’s compliance tools, including a How-to Guide and Help Desk, and found access to utility data to be straightforward. However, almost one-third of the respondents encountered challenges when estimating the gross floor area (GFA), and some experienced confusion regarding the input of property use types and details into ESPM. Based on the RIA team’s recommendations, the City refined its How-to Guide, created online answers to frequently asked questions, and hosted office hour sessions to help building managers accurately characterize their building’s physical characteristics and operations in ESPM. Concurrently with the RIA team’s evaluation, the City worked with PNNL to estimate DOE Asset Score Preview (Preview) scores for 181 of the 340 commercial buildings that submitted ESPM reports to the City. Asset Score Tool is a web-based tool developed by PNNL for DOE to evaluate and rate the as-built energy efficiency of a building. Asset Score Tool’s full analysis capability runs a detailed energy model based on building geometry, age, envelope, lighting and mechanical systems using standard operating assumptions to give the building a score, similar to a miles per gallon rating for a car. Preview, a simplified deployment of the full Asset Score Tool, provides a preliminary score range using only seven data points, six of which are readily available in the ESPM benchmarking data. Analysis of the combined Preview scores and the operational ESPM scores identified buildings with a high potential for energy improvements through either retro-commissioning and retuning of existing operations or capital investments into building systems. The City contracted Whole Building Solutions (WBS) to mine building permit history and develop full Asset Scores for a subset of 26 office buildings that were eligible for both ENERGY STAR scores and Asset Scores. WBS researched permits and building plans to identify mechanical, lighting and envelope systems and other building characteristics necessary to complete Asset Scores. This historical data was recorded using the web-based Asset Score Tool, which evaluates the as designed energy efficiency of existing buildings. Much of this City information was available online after 2010; however, WBS had to search through microfiche files and the City’s database to obtain permit and plan history prior to 2010. Although building geometry, mechanical system type and basic envelope information was consistently identifiable, WBS found permit data gaps that prevented complete and accurate Asset Scores for most of the office buildings. If the City decides to develop Asset Scores based on building permit information in the future, WBS recommended requiring lighting plans, control diagrams and as-built drawings that reflect how the buildings are actually constructed. In addition, WBS recommended uploading plans and permits from microfiche storage into a more comprehensive, searchable database consistent with the City’s current online permit information. To identify the actual lighting types, WBS and City staff conducted site visits of all 26 office buildings. As part of managing the flow of ESPM and Asset Score data for the project, Earth Advantage, a sub-recipient of the Cities-LEAP award, created a DOE Standard Energy Efficiency Data (SEED) (USDOE 2018) instance for the City and used Asset Score’s Application Programming Interface (API) (Asset Score 2018) capabilities to develop two new features in the SEED Platform™: (1) automated Asset Score Preview ranges calculated based on benchmarking data and the City’s estimate of number of building floors; and (2) storage of full Asset Score information. Leveraging the construction permit history and site visit information for the 26 office buildings, The Cadmus Group (Cadmus) analyzed benchmarking data and Asset Score information to identify opportunities and drivers to improve performance. Correlation and regression analysis of the combined dataset was completed to determine whether building operations or specific systems – mechanical, lighting or envelope – present the best opportunities to improve energy performance. The central outcome of this project was Cadmus’ detailed analysis of the richer dataset that was created by combining the City of Portland’s commercial building permit activity and building-specific energy performance information based on metrics from ESPM and Asset Score Tool. Some of their findings collaborate with well-known facts, such as buildings with less efficient lighting systems are good targets for efficiency improvements through lighting upgrades. This analysis also helped identify that individual heating, ventilation, and air conditioning (HVAC) equipment efficiency does not necessarily correlate with building performance. However, overall HVAC system performance, as measured with the Total System Performance Ratio (TSPR) metric, is a better indicator of building performance (Goel et al. 2014). As a metric, TSPR considers whole system performance that includes equipment efficiency and system controls, such as resets for static pressure and chilled water setpoints, which can be more effective and financially feasible options for improving building performance. Given the high cost associated with envelope retrofits, opportunities to upgrade envelope insulation are likely to be limited. However, buildings with single-pane and non-thermal break windows are good candidates for window replacements, such as upgrading to double-pane windows with thermal breaks. This research project determined that developing Asset Scores based on site visits is preferable to mining City building permit data. In addition, the use of benchmarking data to develop Asset Score Preview Scores is recommended as a first step in engaging building managers to develop full Asset Scores. Asset Score Tool outputs can help building managers quickly identify opportunities for improvement and then work with the utility incentive administrator and energy service providers to develop their retrofit plan. Where full Asset Scores are available, analysis using a quadrant matrix with ENERGY STAR scores is recommended to identify buildings that present the best opportunities for operational-behavioral improvements versus ones with opportunities for upgrades to physical building systems. This workflow and the tools will help cities, utility incentive administrators, building portfolio managers and energy service providers develop energy programs and strategies for screening and analysis of buildings with the greatest energy savings potential. This report describes the project approach and research results to inform future coordination of ESPM and Asset Score data, including the use of benchmarking data to generate Preview scores. Given better awareness of energy performance, building managers can make more informed decisions to reduce energy consumption and carbon emissions. With cities, states and jurisdictions adopting benchmarking and auditing ordinances, there are substantial amounts of data submitted to cities that could be used to inform investments in energy efficiency.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗