Search NASA⌕ Search

SEARCH · Search NASA

Results for “permeability characterization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

977 records · Page 55

Generation, characterization and in vivo biological activity of two distinct monoclonal anti-PEG IgMs

PEGylation, the attachment of polyethylene glycol (PEG) to nanocarriers and proteins, is a widely accepted approach to improving the in vivo efficacy of the non-PEGylated products. However, both PEGylated liposomes and PEGylated proteins reportedly trigger the production of specific antibodies, mainly IgM, against the PEG moiety, which possibly leads to a reduction in safety and therapeutic efficacy of the PEGylated products. In the present study, two monoclonal anti-PEG IgMs — HIK-M09 via immunization with an intravenous injection of PEGylated liposomes (SLs) and HIK-M11 via immunization with a subcutaneous administration of PEGylated ovalbumin (PEG-OVA) were successfully generated. The generated IgMs showed efficient reactivity to mPEG{sub 2000} conjugated to 1,2-distearoyl-sn-glycero-3-phospho-ethanolamine (DSPE), PEGylated liposome (SL) and PEG-OVA. It appears that HIK-M09 recognizes ethoxy (OCH{sub 2}CH{sub 2}) repeat units along with a terminal motif of PEG, while HIK-M11 recognizes only ethoxy repeat units of PEG. Such unique properties allow HIK-M09 to bind with dense PEG. In addition, their impact on the in vivo clearance of the PEGylated products was investigated. It was found that the generated ant-PEG IgMs induced a clearance of SL as they were intravenously administered with SL. Interestingly, the HIK-M11, generated by PEG-OVA, induced the clearance of both SL and PEG-OVA, while the HIK-M09, generated by SL, induced the clearance of SL only. We here revealed that the presence of serum anti-PEG IgM and the subsequent binding of anti-PEG IgM to the PEGylated products are not necessarily related to the enhanced clearance of the products. It appears that subsequent complement activation following anti-PEG IgM binding is the most important step in dictating the in vivo fate of PEGylated products. This study may have implications for the design, development and clinical application of PEGylated products and therapeutics. - Highlights: • Two monoclonal anti-PEG IgMs were generated against distinct PEGylated materials. • In vivo cross-reactivity to the immunized materials was limited. • Although in vitro cross-reactivity of generated monoclonal IgMs has been confirmed.

60 APPLIED LIFE SCIENCES↗

Evaluation of Bentonite Engineered Barrier Performance under Repository Conditions

Nuclear energy has been an important source of power throughout the world for several decades, but with that power comes substantial amounts of waste. The USA alone is projected to produce 77,100 MTHM (34,700 MCi) of commercial spent fuel by the year 2020. There has been a growing sense of urgency to determine a method of disposal for all types of nuclear waste. Underground storage has been proposed as the safest means of long term storage and disposal by both the Academy of Sciences and the Blue Ribbon Commission with a focus on deep geologic disposal. Because deep geological repositories (DGR) pose as the safest method of disposal due to the isolation of the waste and the low-permeability of the surrounding material, it is crucial to understand the science behind these repositories. Many scientists have concern with DGRs because of all the unanswered scientific questions. With a global inventory of 300,000 MTHM, it is imperative to understand how DGRs will retain the nuclear waste over a time span of up to a projected 1 million years. Because of the amount of nuclear waste increases each year, there is an inherent need to study the viability of a repository in order to begin implementation of that repository. Based on the half-lives of each radionuclide in nuclear waste, after approximately 100 years of storage, the heat production from the decay of radionuclides becomes dominated by the long-lived actinides. Because the decay of the nuclear waste results in an elevated temperature within the canister, That mixed with water intrusion can corrode the canister and allow radionuclides to leach into the surrounding environment. In an effort to retain these radionuclides within the repositories, most all deep geologic repository designs incorporate an engineered multi-barrier approach. Once the radionuclides begin to leach out of the canisters, the next barrier to retain them is a layer of compacted clay such as a smectite. A mechanistic understanding of mobility at elevated temperatures is crucial in order to evaluate the performance of the engineered clay barrier system within a deep geological repository. Because the clay barrier is compacted so tightly, the only method of mobility for radionuclides is through molecular diffusion. Assessing the factors that affect the rates at which various radionuclides will diffuse through these clays is important in the performance assessment of the repository system as a whole. Neptunium-237 has been identified as a major actinide of concern for long term storage, dominating the radioactivity emitted from the waste between 10,000 to 100,000 years of storage. Under oxidizing conditions, this radionuclide exists mainly as Np(V). In this oxidation state, the neptunium exists chemically as the NpO{sub 2}{sup +} ion which exhibits enhanced mobility characteristics such as high solubility and low affinity for sorption to surfaces. Because of this, {sup 237}Np(V) has been identified as the most mobile radionuclide in nuclear waste and thus a major radionuclide of concern, motivating research into the mobility of {sup 237}Np(V) through the compacted clay barrier. Bentonite is one of the most common backfill materials used in repositories. This clayey rock's main constituent is the mineral Na-montmorillonite [(Ca{sub 0.06}Na{sub 0.14}K{sub 0.05})(Al{sub 1.57}Fe{sup 3+} {sub 0.17}Mg{sub 0.25})(Al{sub 0.04}Si{sub 3.96}O{sub 10} - (OH){sub 2})] which gives this material the advantageous properties required for a repository such as a high swelling capacity. Because of this high affinity for absorbing water, montmorillonite is the ideal candidate for backfill material in a deep geological repository. Adsorption of radionuclides onto the surface of the compacted clay is a major mechanism for retardation of mobility. Because diffusion and adsorption are integrated into this process, it is important to characterize Np adsorption onto the surface of compacted montmorillonite. Previous studies have quantified the adsorption of Np onto montmorillonite at variable ionic strengths and temperatures. Furthermore, several studies have focused on the diffusion of Np through compacted clay, but no other studies have determined diffusion coefficients at elevated temperatures of up to 80 deg. C. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Recover Act. Verification of Geothermal Tracer Methods in Highly Constrained Field Experiments

The prediction of the geothermal system efficiency is strong linked to the character of the flow system that connects injector and producer wells. If water flow develops channels or “short circuiting” between injection and extraction wells thermal sweep is poor and much of the reservoir is left untapped. The purpose of this project was to understand how channelized flow develops in fracture geothermal reservoirs and how it can be measured in the field. We explored two methods of assessing channelization: hydraulic connectivity tests and tracer tests. These methods were tested at a field site using two verification methods: ground penetrating radar (GPR) images of saline tracer and heat transfer measurements using distributed temperature sensing (DTS). The field site for these studies was the Altona Flat Fractured Rock Research Site located in northeastern New York State. Altona Flat Rock is an experimental site considered a geologic analog for some geothermal reservoirs given its low matrix porosity. Because soil overburden is thin, it provided unique access to saturated bedrock fractures and the ability image using GPR which does not effectively penetrate most soils. Five boreholes were drilled in a “five spot” pattern covering 100 m2 and hydraulically isolated in a single bedding plane fracture. This simple system allowed a complete characterization of the fracture. Nine small diameter boreholes were drilled from the surface to just above the fracture to allow the measurement of heat transfer between the fracture and the rock matrix. The focus of the hydraulic investigation was periodic hydraulic testing. In such tests, rather than pumping or injection in a well at a constant rate, flow is varied to produce an oscillating pressure signal. This pressure signal is sensed in other wells and the attenuation and phase lag between the source and receptor is an indication of hydraulic connection. We found that these tests were much more effective than constant pumping tests in identifying a poorly connected well. As a result, we were able to predict which well pairs would demonstrate channelized flow. The focus of the tracer investigation was multi-ionic tests. In multi-ionic tests several ionic tracers are injected simultaneously and the detected in a nearby pumping well. The time history of concentration, or breakthrough curve, will show a separation of the tracers. Anionic tracers travel with the water but cationic tracer undergo chemical exchange with cations on the surface of the rock. The degree of separation is indicative of the surface area exposed to the tracer. Consequently, flow channelization will tend to decrease the separation in the breakthrough. Estimation of specific surface area (the ration of fracture surface area to formation volume) is performed through matching the breakthrough curve with a transport model. We found that the tracer estimates of surface area were confirmed the prediction of channelized flow between well pairs produced by the periodic hydraulic tests. To confirm that the hydraulic and tracer tests were correctly predicting channelize flow, we imaged the flow field using surface GPR. Saline water was injected between the well pairs which produced a change in the amplitude and phase of the reflected radar signal. A map was produced of the migration of saline tracer from these tests which qualitatively confirmed the flow channelization predicted by the hydraulic and tracer tests. The resolution of the GPR was insufficient to quantitatively estimate swept surface area, however. Surface GPR is not applicable in typical geothermal fields because the penetration depths do not exceed 10’s of meters. Nevertheless, the method of using of phase to measure electrical conductivity and the assessment of antennae polarization represent a significant advancement in the field of surface GPR. The effect of flow character on fracture / rock thermal exchange was evaluated using heated water as a tracer. Water elevated 30 degrees C above the formation water was circulated between two wells pairs. One well pair had been identified in hydraulic and tracer testing as well connected and the other poorly connected. Temperature rise was measured in the adjacent rock matrix using coiled fiber optic cable interrogated for temperature using a DTS. This experimental design produced over 4000 temperature measurements every hour. We found that heat transfer between the fracture and the rock matrix was highly impacted by the character of the flow field. The strongly connected wells which had demonstrated flow channelization produced heat rise in a much more limited area than the more poorly connected wells. In addition, the heat increase followed the natural permeability of the fracture rather than the induced flow field. The primary findings of this work are (1) even in a single relatively planar fracture, the flow field can be highly heterogeneous and exhibit flow channeling, (2) channeling results from a combination of fracture permeability structure and the induced flow field, and (3) flow channeling leads to reduced heat transfer. Multi-ionic tracers effectively estimate relative surface area but an estimate of ion-exchange coefficients are necessary to provide an absolute measure of specific surface area. Periodic hydraulic tests also proved a relative indicator of connectivity but cannot prove an absolute measure of specific surface area.

15 GEOTHERMAL ENERGY↗

Ordovician-Cambrian Units: Hierarchical Evaluation of Geologic Carbon Storage Resource Estimates

The Indiana Geological and Water Survey (IGWS) led subtask 1.1 to assess the regional distribution and estimate the storage capacity of Ordovician-Cambrian stratigraphic units located within the partnership region. A comprehensive data set of wireline logs and petrophysical information was used to generate these interpretations. These data include core analysis for porosity and permeability, mercury injection capillary pressure (MICP), and existing well data including location and stratigraphic information. This report includes storage resource estimates (SREs) for three potential storage reservoirs(limestone and dolostone from the Upper Ordovician Trenton Limestone/Black River Group and equivalent units, the Middle Ordovician St. Peter Sandstone, and primary target reservoir rocks of the Lower Ordovician and Upper Cambrian Knox Supergroup and equivalent units) calculated using six methodologies: (1) a fixed value of porosity of 10 percent in all units evaluated; (2) a unique average porosity (per well) from wireline-derived porosity (neutron, sonic, and/or density porosity for each unit); (3) porosity values from core analysis; (4) a depth-dependent porosity model (Knox Supergroup only); (5) porosity based on a model based on petrophysical facies; and (6) SREs using National Energy Technology Laboratory’s CO2 Storage prospeCtive Resource Estimation Excel aNalysis (CO2-SCREEN beta V2). All methods used the same values for thickness for each unit. However, the areal extent of each assessment was limited by the data available for each method. Estimated volumes were calculated in 1-by-1 kilometer grid cells and summarized as county and total stratigraphic unit volumes. The resultant SREs mass are displayed using boxplots, which allow for comparing data statistics (mean values and variability) between methods. Differences observed in SRE results from the six methods are mainly attributable to differences in the data and conceptual models used to interpret or estimate porosity in each method. Based on this systematic variability between methods, it is inferred that methods 1, 4, and 6 are best used for regional-scale reconnaissance estimates of storage capacity while methods 2, 3, and 5 are more appropriate for local scales where more data is required. All estimates are data-density dependent and different methods require different amounts of data for reasonable assessments. ArcMap 10.5.1 software was used to portray SREs to help visualize spatial variance of estimates for each methodology, and more importantly, to highlight those areas having the greatest total storage potential estimates.

01 COAL, LIGNITE, AND PEAT↗

Annual report of monitoring at Barnes, Kansas, in 2010.

The Commodity Credit Corporation of the U.S. Department of Agriculture (CCC/USDA) operated a grain storage facility at Barnes, Kansas, in 1949-1974. Carbon tetrachloride contamination was initially detected in 1986 in the town's public water supply wells. In 2006-2007, the CCC/USDA conducted a comprehensive targeted investigation at and near its former property in Barnes to characterize this contamination. Those results were reported previously (Argonne 2008a). The results of that investigation indicated that carbon tetrachloride contamination is present in groundwater at low to moderate levels in the vicinity of the former CCC/USDA grain storage facility. Information obtained during the 2006-2007 investigation also indicated that at least one other potential source might have contributed to the groundwater contaminant plume (Argonne 2008a). The former agriculture building owned by the local school district, located immediately east of well PWS3, is also a potential source of the contamination. In November 2007, the CCC/USDA began periodic groundwater monitoring at Barnes. The monitoring is being conducted on behalf of the CCC/USDA by Argonne National Laboratory, under the direction of the Kansas Department of Health and Environment (KDHE). The objective is to monitor the carbon tetrachloride contamination identified in the groundwater at Barnes. Through 2010, sampling was conducted in a network of 28 individual monitoring wells (at 19 distinct locations), 2 public water supply wells, and 1 private well (Figure 1.1). The results of the 2006-2007 targeted investigation and the subsequent monitoring events (Argonne 2008a-d, 2009a,b, 2010) demonstrated the presence of carbon tetrachloride contamination in groundwater at levels exceeding the KDHE Tier 2 risk-based screening level (RBSL) of 5.0 {micro}g/L for this compound. The contaminant plume appears to extend from the former CCC/USDA property northwestward, toward the Barnes public water supply wells. Long-term monitoring of the groundwater levels and the contaminant distribution has confirmed that pumping of the public water supply wells affects the direction of groundwater flow. When these wells are not pumping, the direction of groundwater flow is to the northeast. However, when they are pumping, groundwater flow is directed to the northwest, toward the public wells. A contingency interim measure (Argonne 2009c) has been approved by the KDHE (2009) and will be implemented if the two operating public water supply wells become contaminated at levels above the RBSL of 5.0 {micro}g/L for carbon tetrachloride. This current report presents the results of monitoring conducted in 2010. Sampling of the monitoring well network was conducted in March-April 2010 and September 2010. In addition, the two operating public water supply wells were sampled in June 2010 and December 2010. On the basis of an evaluation of the data collected in 2006-2009 (Argonne 2010), including a trend analysis of the site contamination and its migration, the KDHE (2010) concurred that future monitoring will occur on an annual basis, with twice-yearly sampling of the two public water supply wells in service (conducted in cooperation with the city). The KDHE (2010) also agreed to decrease the number wells to be sampled in the future, as discussed in Section 5.

54 ENVIRONMENTAL SCIENCES↗