Search NASA⌕ Search

SEARCH · Search NASA

Results for “rf source”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 991 records · Page 55

Parameter Selection and Longitudinal Phase Space Simulation for a Single Stage X-Band FEL Driver at 250 MeV

Hard x-ray Free electron lasers (FEL) are being built or proposed at many accelerator laboratories as it supports wide range of applications in many aspects. Most of the hard x-ray FEL design is similar with the SLAC Linac Coherent Light Source (LCLS), which features a two (or multiple) stage bunch compression. For the first stage of the bunch compression, usually the beam is accelerated in a lower-frequency RF section (such as S-band for LCLS), and then the longitudinal phase space is linearized by a higher-frequency RF section (harmonic RF, such as X-band for LCLS). In this paper, a compact hard x-ray FEL design is proposed, which is based on X-band RF acceleration and eliminating the need of a harmonic RF. The parameter selection and relation is discussed, and the longitudinal phase space simulation is presented. The FEL coherence condition of the electron beam in the undulators requires a large charge density, a small emittance and small energy spread. The RMS electron bunch length from the injector is in the ps scale, with a bunch charge in the range of hundreds pC to several nC, which means that the current is roughly 0.1 kA. According to the requirement from soft x-ray lasing and hard x-ray lasing, a peak current of 1 kA and 3 kA is needed respectively. Thus the bunch has to be compressed. Usually a two stage bunch compression or multipole stage bunch compression is adopted. The z-correlated energy chirp is normally established by letting the beam pass through a section of RF cavities, with a RF phase off crest. As stated above, S-band RF (3 GHz) acceleration could be applied in this section. Due to the nature of RF acceleration wave, the chirp on the bunch is not linear, but has the RF curvature on it. In order to linearize the energy chirp, a harmonic RF section with higher frequency is needed. For LCLS a short X-band RF section (12 GHz) is used which is a fourth order harmonic. The linearized bunch is then passing by a dispersive region, in which the particles with different energy have different path length. A four dipole chicane is the natural choice for the dispersive region. As the example illustrated in Figure 1, the head of the bunch has smaller energy, and gets a stronger bending kick from the dipole magnet, then has a longer path length in the dispersive region. Similarly, the tail of the bunch has larger energy and shorter path length in the dispersive region. At the exit of the dispersive region, the relative longitudinal position of the head and tail of the bunch both move to the center of the bunch, so the bunch length will be shorter.

43 PARTICLE ACCELERATORS↗

Widely tunable 11 GHz femtosecond fiber laser based on a nonmode-locked source [Widely tunable 11 GHz femtosecond fiber laser based on a non-modelocked source]

An 11 GHz fiber laser built on a modulated CW platform is described and characterized. This compact, vibrationinsensitive, fiber based system can be operated at wavelengths compatible with high energy fiber technology, is driven by an RF signal directly, and is tunable over a wide range of drive frequencies. The demonstration system when operated at 1040 nm is capable of 50 ns bursts of 575 micro-pulses produced at a macro-pulse rate of 83 kHz where the macro-pulse and micro-pulse energies are 1.8 μJ and 3.2 nJ respectively. Micro-pulse durations of 850 fs are demonstrated. Finally, we discuss extensions to shorter duration.

42 ENGINEERING↗

Thermal evaluation method for Klystron RF power

The feasibility of adding instrumentation to the cooling system of a microwave transmitter for use as a calorimetric power measurement calibration is examined. It considers the accuracy of the basic measurements as well as heat sources and losses not measured. Experimental results are presented in support of the theory.

Conroy, B. L.↗

Predicting measures of soil health using the microbiome and supervised machine learning

Soil health encompasses a range of biological, chemical, and physical soil properties that sustain the commercial and ecological value of agroecosystems. Monitoring soil health requires a comprehensive set of diagnostics that can be cost-prohibitive for routine analyses. The soil microbiome provides a rich source of information about soil properties, which can be assayed in a high-throughput, cost-effective way. We evaluated the accuracy of random forest (RF) and support vector machine (SVM) regression and classification models in predicting 12 measures of soil health, tillage status, and soil texture from 16S rRNA gene amplicon data with an operationally relevant sample set. We validated the efficacy of the best performing models against independent datasets and also tested best practices for processing microbiome data for use in machine learning. Soil health metrics could be predicted from microbiome data with the best models achieving a Kappa value of ~0.65, for categorical assessments, and a R2 value of ~0.8, for numerical scores. Biological health ratings were better predicted than chemical or physical ratings. Validation with independent datasets revealed that models had general predictive value for soil properties, including yield. The ecological profiles of several taxa important for model accuracy matched the observed relationships with soil health, including Pyrinomonadaceae, Nitrososphaeraceae, and Candidatus Udeaobacter. Models trained at the highest taxonomic resolution proved most accurate, with losses in accuracy resulting from rarefying, sparsity filtering, and aggregating at higher taxonomic ranks. Furthermore, our study provides the groundwork for developing scalable technology to use microbiome-based diagnostics for the assessment of soil health.

16S rRNA gene↗

Deuteron injector for Peking University Neutron Imaging Facility project

The deuteron injector developed for the PKUNIFTY (Peking University Neutron Imaging Facility) has been installed and commissioned at Peking University (PKU). The injector system must transfer 50 keV 50 mA of D{sup +} ion beam to the entrance of the 2 MeV radio frequency quadrupole (RFQ) with 10% duty factor (1 ms, 100 Hz). A compact 2.45 GHz permanent magnet electron cyclotron resonance (PMECR) ion source and a 1.36 m long low energy beam transport (LEBT) line using two solenoids was developed as the deuteron injector. A {phi}5 mm four-quadrant diaphragm was used to simulate the entrance of RFQ electrodes. The beam parameters are measured after this core with an emittance measurement unit (EMU) and a bending magnet for ion fraction analysis at the end of injector. During the commissioning, 77 mA of total deuteron beam was extracted from PMECR and 56 mA of pure D{sup +} beam that passed through the {phi}5 mm four-quadrant diaphragm was obtained at the position of RFQ entrance with the measured normalized rms emittance 0.12-0.16{pi} mm mrad. Ion species analysis results show that the deuteron fraction is as high as 99.5%. All of the parameters satisfy PKUNIFTY's requirements. In this paper, we will describe the deuteron injector design and report the commissioning results as well as the initial operation.

43 PARTICLE ACCELERATORS↗

Improved efficiency and precise temperature control of low-frequency induction-heating pure iron vapor source on ECR ion source

Multiply charged ions to be used prospectively are produced from solid pure material in an electron cyclotron resonance ion source (ECRIS). Recently a pure iron source is also required for the production of caged iron ions in the fullerene in order to control cells in vivo in bio-nano science and technology. We adopt directly heating iron rod by induction heating (IH) because it has non-contact with insulated materials which are impurity gas sources. We choose molybdenum wire for the IH coils because it doesn't need water cooling. To improve power efficiency and temperature control, we propose to the new circuit without previously using the serial and parallel dummy coils (SPD) for matching and safety. We made the circuit consisted of inductively coupled coils which are thin-flat and helix shape, and which insulates the IH power source from the evaporator. This coupling coils circuit, i.e. insulated induction heating coil transformer (IHCT), can be move mechanically. The secondary current can be adjusted precisely and continuously. Heating efficiency by using the IHCT is much higher than those of previous experiments by using the SPD, because leakage flux is decreased and matching is improved simultaneously. We are able to adjust the temperature in heating the vapor source around melting point. And then the vapor pressure can be controlled precisely by using the IHCT. We can control {+-}10K around 1500 Degree-Sign C by this method, and also recognize to controlling iron vapor flux experimentally in the extreme low pressures. Now we come into next stage of developing induction heating vapor source for materials with furthermore high temperature melting points above 2000K with the IHCT, and then apply it in our ECRIS.

74 ATOMIC AND MOLECULAR PHYSICS↗

Radio frequency plasma power dependence of the moisture permeation barrier characteristics of Al{sub 2}O{sub 3} films deposited by remote plasma atomic layer deposition

In the present study, we investigated the gas and moisture permeation barrier properties of Al{sub 2}O{sub 3} films deposited on polyethersulfone films (PES) by capacitively coupled plasma (CCP) type Remote Plasma Atomic Layer Deposition (RPALD) at Radio Frequency (RF) plasma powers ranging from 100 W to 400 W in 100 W increments using Trimethylaluminum [TMA, Al(CH{sub 3}){sub 3}] as the Al source and O{sub 2} plasma as the reactant. To study the gas and moisture permeation barrier properties of 100-nm-thick Al{sub 2}O{sub 3} at various plasma powers, the Water Vapor Transmission Rate (WVTR) was measured using an electrical Ca degradation test. WVTR decreased as plasma power increased with WVTR values for 400 W and 100 W of 2.6 × 10{sup −4} gm{sup −2}day{sup −1} and 1.2 × 10{sup −3} gm{sup −2}day{sup −1}, respectively. The trends for life time, Al-O and O-H bond, density, and stoichiometry were similar to that of WVTR with improvement associated with increasing plasma power. Further, among plasma power ranging from 100 W to 400 W, the highest power of 400 W resulted in the best moisture permeation barrier properties. This result was attributed to differences in volume and amount of ion and radical fluxes, to join the ALD process, generated by O{sub 2} plasma as the plasma power changed during ALD process, which was determined using a plasma diagnosis technique called the Floating Harmonic Method (FHM). Plasma diagnosis by FHM revealed an increase in ion flux with increasing plasma power. With respect to the ALD process, our results indicated that higher plasma power generated increased ion and radical flux compared with lower plasma power. Thus, a higher plasma power provides the best gas and moisture permeation barrier properties.

36 MATERIALS SCIENCE↗

Formation of niobium hydride precipitates in superconducting qubits

We report evidence for the formation of niobium hydride phase within niobium films on silicon substrates in superconducting qubits fabricated at Rigetti Computing. For this study, we combined complementary techniques—including room-temperature and cryogenic atomic force microscopy (AFM), synchrotron x-ray diffraction, and time-of-flight secondary ion mass spectroscopy (ToF-SIMS)—to directly reveal the existence of niobium hydride precipitates on the surface of superconducting qubits. Upon cryogenic cooling, we observed variation in the size and morphology of the hydrides, ranging from small (∼5 nm) irregular shapes to large (∼10–100 nm) domains within the Nb grains, which were fully converted to niobium hydrides. Since niobium hydrides are nonsuperconducting and can easily change in size and location upon different cooldowns to cryogenic temperature, our finding highlights a previously unknown source of decoherence in superconducting qubits. This contributes to quasiparticle losses, offering a potential explanation for changes in qubit performance upon cooldowns. Finally, by leveraging the RF performance of a 3D bulk Nb resonator, we quantify RF dissipation in a superconducting qubit caused by hydrogen concentration variation, and propose a practical engineering pathway to mitigate the formation of Nb hydrides for superconducting qubit applications.

Sung, Zuhawn [Fermi National Accelerator Laborator↗

Preliminary Transverse Shielding Analysis for the 1010-C RF Building

EIC is planning to construct a new building on the outer ring berm at 10 o’clock which will provide RF power to cryogenically-cooled beam line components in the electron and hadron storage rings. The distance of the building from the RHIC Tunnel and the amount of soil shielding required are the focus of this report. Siting the building closer to the RHIC Tunnel is desirable from an RF operations viewpoint since the waveguide runs and RF power losses will be minimized, but this may require the use of higher density shield materials, e.g., concrete, in addition to soil shielding. The radiological source terms are the prompt radiation hazards from the Hadron Storage Ring (HSR) and Electron Storage Ring (ESR) beam losses in the 10 o’clock sector and the lateral dose rates propagated through the shields. See Figure 1 below.

43 PARTICLE ACCELERATORS↗

The TWERLE balloon-to-satellite data transmitting system

This paper describes the balloon instrumentation system which provides the one-way link for data gathering and navigation in the Tropical Wind, Energy conversion and Reference Level Experiment (TWERLE). In this experiment, 400 instrumented constant-level balloons will be launched at the southern hemisphere during 1975. The Random Access Measurement System (RAMS) on board the Nimbus-F satellite, will comprise the receiving end of the link. The data encoder, stable oscillator, transmitter and antenna are described, as well as two supporting components, the power source and the magnetic cutdown. These six items weigh 850 g. The oscillator-transmitter consume 1.9 W dc power to provide 0.6 W phase modulated RF power.

Levanon, N.↗

Multiple frequency electron cyclotron resonance thruster

An electron cyclotron resonance (ECR) thruster includes a magnetic field source configured to generate a magnetic field, a thruster body that defines a chamber, the thruster body being disposed relative to the magnetic field source such that the magnetic field is present in the chamber and such that a magnetic nozzle is established, an antenna configured to propagate radio frequency (RF) power within the chamber, and a waveform generator coupled to the antenna to generate an RF waveform for the RF power. The waveform generator is configured such that the RF waveform includes multiple frequencies.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Characterizing the plasma-induced thermal loads on a 200 kW light-ion helicon plasma source via infra-red thermography

The light-ion helicon plasma source of the Proto-MPEX linear plasma device has been recently upgraded to enable pulsed (0.5–1 s) operation up to 200 kW. The main objective of this work is to report on the plasma-induced surface heat fluxes incident on the helicon window during high power operation (60–150 kW net power) for the purpose of the design of the upcoming material plasma exposure eXperiment (MPEX). The IR imaging system and associated physics models for the extraction of surface heat fluxes are presented. Furthermore, experimental results demonstrate that the control of the plasma strike point via magnetic flux mapping and the use of dedicated limiters is effective at reducing the heat loads on the dielectric window. Moreover, it is found that the flux mapping must create a gap between the plasma and the dielectric window of at least the plasma radial decay length. Extrapolated to 200 kW net RF power, this mode of operation can reduce the power lost to the dielectric window by 33%. The results presented have direct application to the design of high-powered helicon plasma sources that operate in a steady state. Examples include linear divertor simulators such as MPEX, electric thrusters, negative ion sources for NBI and linear plasma–material interaction test stands.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Estimation of the ion toroidal rotation source due to momentum transfer from Lower Hybrid waves in Alcator C-Mod

Significant ion toroidal rotation (50km/s) has been measured by X-Ray spectroscopy for impurities in Alcator C-Mod during lower hybrid (LH) RF power injection. We investigate the relation between the computed toroidal momentum input from LH waves and the measured INITIAL change of ion toroidal rotation when the LH power is turned on. The relation may depend on the plasma current and magnetic configuration. Because of the fast build up time of the electron quasilinear plateau (<1 millisecond), the electron distribution function rapidly reaches steady state in which the electrons transfer momentum to the ions. The LH wave momentum input is computed from the self consistent steady state electron distribution function and a bounce-averaged quasilinear diffusion coefficient that are obtained by iterating a full wave code (TORLH) with a Fokker Plank code (CQL3D)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Combined Optical and Radio-Frequency Perspectives on a Hybrid Cloud-To-Ground Lightning Flash Observed by the FORTE Satellite

In this work, we use the coincident optical and radio-frequency (RF) measurements taken by the Fast On-orbit Recording of Transient Events (FORTE) satellite to shed light on common optical signatures recorded by NASA and NOAA lightning imagers during Cloud-to-Ground (CG) lightning. We build flash cluster data for FORTE using the same techniques as the NASA/NOAA instruments to document the optical/RF evolution of an oceanic hybrid -CG flash. The flash began with strong Very High Frequency (VHF)-band emission from a Narrow Bipolar Event (NBE) that initiated a period of normal bilevel intracloud (IC) activity in two vertical layers (8 and 12 km) that lasted for 490 ms. VHF waveforms show step leader activity ahead of the return stroke. All impulsive VHF sources after the stroke come from the lower (8 km) layer. K-changes are noted following the return stroke, but no subsequent strokes are detected. The optical flash began 136 ms after the NBE RF pulse. Twenty-two of the 33 optical groups were dim and occurred during the in-cloud phase of the flash. This activity included both isolated pulses and sustained periods of illumination over tens of milliseconds. Initial cloud pulses accounted for 23% of the total optical radiance from the flash. Illumination during the return stroke contributed 58% of the total radiance, and the K-changes and cloud pulses after the stroke supplied the remaining 19%. These results highlight the benefit of having RF alongside optical lightning measurements for clarifying signatures in the optical data and providing information on their physical origins.

54 ENVIRONMENTAL SCIENCES↗

Phase Drifts and Signal Dispersion in Coaxial Cables

Phase reference distribution is a critical challenge in modern linear particle accelerators, such as European Spallation Source (ESS), European X-ray Free Electron Laser (E-XFEL), or Proton Improvement Plan II (PIP-II). Similar issues may also arise in other RF systems that need to synchronize many independent circuits. Achieving low phase drift of the reference signal requires careful selection of cables and their environmental operating conditions. Due to the limited data provided by cable manufacturers, it is necessary to characterize the cable performance. This article investigates the phase drifts in coaxial cables and presents a dedicated measurement methodology. The dispersion characteristics of the cables are also examined. The measurement results of various coaxial cables are presented, along with conclusions and practical guidelines for designers of phase reference distribution lines.

coaxial cables↗

Optimization of Binning Parameters in the Feynman Variance-to-Mean Method for Delayed Neutron Reinterrogation

The focus of this work is to determine the optimal input parameters for analyzing active interrogation data that utilizes the physics of the delayed neutron re-interrogation technique. This work compares the signature from an active neutron measurement of a highly enriched uranium (HEU) system to an active background measurement (i.e., without the HEU item in place). The item being measured represents a 21.8 kg metal sphere of HEU (93 weight percent) assembled from a subset of the Rocky Flats (RF) uranium hemishells. The detection system consisted of two NoMAD neutron multiplicity detectors, a SNAP III neutron detector, and a Thermo Fisher P211 pulsed 14 MeV neutron source. In addition, varying analyses of the NoMAD list-mode detector data are performed to determine whether it is preferential to use a particular analysis bin size for producing Feynman histograms, selection of pulses to prevent discrepancies from buildup, or window of time during the pulsed neutron interrogation. This work is still currently ongoing.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ferroelectric Emission Cathodes for Low-Power Electric Propulsion

Low- or no-flow electron emitters are required for low-power electric thrusters, spacecraft plasma contactors, and electrodynamic tether systems to reduce or eliminate the need for propellant/expellant. Expellant-less neutralizers can improve the viability of very low-power colloid thrusters, field emission electric propulsion devices, ion engines, Hall thrusters, and gridded vacuum arc thrusters. The NASA Glenn Research Center (GRC) is evaluating ferroelectric emission (FEE) cathodes as zero expellant flow rate cathode sources for the applications listed above. At GRC, low voltage (100s to approx. 1500 V) operation of FEE cathodes is examined. Initial experiments, with unipolar, bipolar, and RF burst applied voltage, have produced current pulses 250 to 1000 ns in duration with peak currents of up to 2 A at voltages at or below 1500 V. In particular, FEE cathodes driven by RF burst voltages from 1400 to 2000 V peak to peak, at burst frequencies from 70 to 400 kHz, emitted average current densities from 0.1 to 0.7 A/sq cm. Pulse repeatability as a function of input voltage has been initially established. Reliable emission has been achieved in air background at pressures as high as 10(exp -6) Torr.

Kovaleski, Scott D.↗