Search NASA⌕ Search

SEARCH · Search NASA

Results for “sample processing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 991 records · Page 55

Terrestrial case studies of ilmenite exploration and lunar implications

The Space Exploration Initiative (SEI) includes space resource utilization as one of the four architectures to achieve U.S. goals in space. Space resource utilization will make use of lunar resources to support long term activities on the lunar surface. Lunar ilmenite and regolith are two of the materials that can be mined and processed for lunar oxygen production. During this investigation, several sources were reviewed to assess terrestrial exploration methods used for locating ilmenite resources. These sources included published reports on terrestrial ilmenite exploration methods, analytical methods, case histories, chemical and physical properties, and associations with other minerals. Using a terrestrial analog and considering the differences between terrestrial and lunar environmental conditions, rocks, and minerals, exploration methods and analytical instruments can be recommended for a lunar orbiter and lander for assessing lunar resources. Twelve terrestrial case histories were reviewed to gain insight into ilmenite exploration on the Moon. All exploration case histories follow the same pattern. They begin with a model, use remote geophysical techniques, define regional sampling sites from the model and geophysics, narrow down the area of exploration based on the preceding work, collect more samples and cores, and perform laboratory analyses of samples. An important part of this process is the collection of samples to determine the correctness of the model. Surface and core samples are collected in areas expected to contain both high and low concentration of the commodity to test the model. After samples are analyzed and the area of mineralization is defined, reserves are calculated to determine the cost/benefit ratio, the necessary capacity of the processing plant, and the life of the mine. The exploration methods used for locating terrestrial ilmenite resources are reviewed with respect to the petrology, chemistry, and mineral associations of the terrestrial and lunar environments.

Feldman, S. C.↗

Cold-Sprayed NMC622 Composite as a Cathode for Lithium-Ion Batteries

The growing demand for high-energy, low-cost lithium-ion batteries (LIBs) to power electric vehicles (EVs) necessitates advances in both materials and manufacturing processes. Conventional cathode fabrication methods, such as slurry casting and drying, are energy-intensive and pose challenges for scalability and environmental compliance. In this study, we propose cold-spray (CS) deposition as a solvent-free approach for fabricating LiNi 0.6 Mn 0.2 Co 0.2 O 2 (NMC622) composite cathodes. Powder blends of NMC622, poly(vinylidene fluoride) (PVDF), and carbon black (CB) are directly deposited onto stainless steel and Inconel substrates under varied gas temperatures, pressures (and thus velocities), and standoff distances. The effects of temperature on the deposit morphology, coating density, and volume are systematically investigated. Computational fluid dynamics simulations reveal that increasing the gas temperature enhances the particle velocity, narrows the spray angle, and reduces the mass concentration radially at the nozzle outlet. CS deposition results in a dense cathode microstructure, accompanied by fracture in polycrystalline NMC622 particles. X-ray diffraction analysis further verifies that there are no phase changes during the deposition process. The electrochemical performance of the cold-sprayed cathodes reveals an initial capacity of approximately 96 mAh g –1 for single-crystal NMC622 and 167 mAh g –1 for polycrystalline NMC622. While these values are modest compared to state-of-the-art slurry-cast cathodes, which typically exhibit 180–200 mAh g –1 under optimized conditions. The results demonstrate a competitive performance given the solvent-free nature of the CS process and compare favorably with tape-cast samples made from identical feedstock. In conclusion, he CS process enables the formation of dense, binder-integrated cathode coatings without the need for solvent processing, offering a promising pathway for scalable, energy-efficient dry electrode manufacturing of next-generation LIBs.

Batteries↗

Diode step stress program for JANTX1N4570A

The effect of power/temperature step stress when applied to a variety of semiconductor devices was evaluated. Performance of the zener diode JANTX1N4570A manufactured by Siemens and Motorola is reported. A total of 48 samples from each manufacturer was submitted to the process outlined in Table 1. In addition, two control sample units were maintained for verification of the electrical parametric testing.

Source record↗

Pyroxenes in Martian meteorites as petrogenetic indicators

Pyroxenes in Martian meteorites are important recorders of petrogenetic processes. Understanding the details of pyroxene major and minor element compositional variations can provide important insights into those processes. A combination of careful petrographic analysis of natural samples and experimental crystallization studies can lead to better understanding of the processes that gave rise to these samples on Mars. In addition, experimentally determined major, minor and trace element partition coefficients are important for using natural pyroxenes to estimate the compositions of the melts from which they crystallized and the oxidation conditions that prevailed during crystallization. We will report on minor element (Al, Ti, Cr) zoning in nakhlite pyroxenes and in synthetic pyroxenes that we have grown for the purposes of determining pyroxene/melt partition coefficients for Sr and REE. The natural pyroxenes have patchy Al zoning that, by analogy with our experimental pyroxenes, we interpret as sector zoning. The irregular patchy nature of the zoning is probably the result of the vagaries of growth kinetics and local environment during crystal growth. More slowly cooled nakhlites have the most distinct bimodal zoning, with one mode having Al2O3 around 0.5-0.6 wt%, and the other around 0.9 %. Average Al content increases with increasing cooling rate. This feature is puzzling, since the cumulus pyroxenes were almost certainly present at the time of eruption. Al and Ti are strongly correlated, but Cr is completely decoupled from those elements. The synthetic pyroxenes are distinctly sector zoned in Al and Ti, and the sector-to-sector variation in Al within a single crystal has important effects on trace element partition coefficients. Trivalent REE are strongly correlated with Al, while divalent elements (Sr, Eu+2) show a significantly weaker correlation. For example, as the Al2O3 content varies from 0.3 to 0.6 wt % from one sector to another, D(Gd) increases by approx.80% while D(Sr) and D(Eu) only increase by 20-30% at oxygen fugacities near IW. The different Al dependency of D for trivalent REE vs. divalent Eu and Sr considerably complicates the calibration of the Eu oxybarometer.

McKay, Gordon↗

Dynamic Method for Identifying Collected Sample Mass

G-Sample is designed for sample collection missions to identify the presence and quantity of sample material gathered by spacecraft equipped with end effectors. The software method uses a maximum-likelihood estimator to identify the collected sample's mass based on onboard force-sensor measurements, thruster firings, and a dynamics model of the spacecraft. This makes sample mass identification a computation rather than a process requiring additional hardware. Simulation examples of G-Sample are provided for spacecraft model configurations with a sample collection device mounted on the end of an extended boom. In the absence of thrust knowledge errors, the results indicate that G-Sample can identify the amount of collected sample mass to within 10 grams (with 95-percent confidence) by using a force sensor with a noise and quantization floor of 50 micrometers. These results hold even in the presence of realistic parametric uncertainty in actual spacecraft inertia, center-of-mass offset, and first flexibility modes. Thrust profile knowledge is shown to be a dominant sensitivity for G-Sample, entering in a nearly one-to-one relationship with the final mass estimation error. This means thrust profiles should be well characterized with onboard accelerometers prior to sample collection. An overall sample-mass estimation error budget has been developed to approximate the effect of model uncertainty, sensor noise, data rate, and thrust profile error on the expected estimate of collected sample mass.

Carson, John↗

Hindlimb Suspension (HLS) in Rodents for the Study of Intracranial Pressure, Molecular and Histologic Changes in the Eye, and CSF Production Regulation and Resorption: A Status Report of Two Studies

This status report corresponds to two studies tied to an animal experiment being executed at the University of California Davis (Charles Fuller's laboratory). The animal protocol uses the well-documented rat hindlimb suspension (HLS) model, to examine the relationship between cephalic fluid shifts and the regulation of intracranial (ICP) and intraocular (IOP) pressures as well as visual system structure and function. Long Evans rats are subjected to HLS durations of 7, 14, 28 and 90 days. Subgroups of the 90-day animals are studied for recovery periods of 7, 14, 28 or 90 days. All HLS subjects have age-matched cage controls. Various animal cohorts are planned for this study: young males, young females and old males. In addition to the live measures (ICP by telemetry, IOP and retinal parameters by optical coherence tomography) which are shared with the Fuller study, the specific outcomes for this study include: -Gene expression analysis of the retina -Histologic analysis - Analysis of the microvasculature of retina flat mounts by NASA's VESsel GENeration Analysis (VESGEN) Software. To date, the young male and female cohorts are being completed. Due to the need to keep technical variation to a minimum, the histologic and genomic analyses have been delayed until all samples from each cohort are available and can be processed in a single batch per cohort. The samples received so far correspond to young males sacrificed at 7,14, 28 and 90 days of HLS and at 90 days of recovery; and from young females sacrificed at 7, 14 and 28 of HLS. A complementary study titled: "A gene expression and histologic approach to the study of cerebrospinal fluid (CSF) production and outflow in hindlimb suspended rats" seeks to study the molecular components of CSF production and outflow modulation as a result of HLS, bringing a molecular and histologic approach to investigate genome wide expression changes in the arachnoid villi and choroid plexus of HLS rats compared to rats in normal posture.

Theriot, C. A.↗

Invertible Temper Modeling using Normalizing Flows and the Effects of Structure Preserving Loss

Advanced manufacturing research and development is typically small-scale, owing to costly experiments associated with these novel processes. Deep learning techniques could help accelerate this development cycle but frequently struggle in small-data regimes like the advanced manufacturing space. While prior work has applied deep learning to modeling visually plausible advanced manufacturing microstructures, little work has been done on data-driven modeling of how microstructures are affected by heat treatment, or assessing the degree to which synthetic microstructures are able to support existing workflows. We propose to address this gap by using invertible neural networks (normalizing flows) to model the effects of heat treatment, e.g., tempering. The model is developed using scanning electron microscope imagery from samples produced using shear-assisted processing and extrusion (ShAPE) manufacturing. This approach not only produces visually and topologically plausible samples, but also captures information related to a sample’s material properties or experimental process parameters. We also demonstrate that topological data analysis, used in prior work to characterize microstructures, can also be used to stabilize model training, preserve structure, and improve downstream results. We assess directions for future work and identify our approach as an important step towards end-to-end deep learning system for accelerating advanced manufacturing research and development.

Howland, Sylvia↗

Development of replicated optics for AXAF-1 XDA testing

Advanced optical systems for applications such as grazing incidence Wolter I x-ray mirror assemblies require extraordinary mirror surfaces in terms of fine finish and surface figure. The impeccable mirror surface is on the inside of the rotational mirror form. One practical method of producing devices with these requirements is to first fabricate an exterior surface for the optical device then replicate that surface to have the inverse component with lightweight characteristics. The replicated optic is not better than the master or mandrel from which it is made. This task identifies methods and materials for forming these extremely low roughness optical components. The objectives of this contract were to (1) prepare replication samples of electroless nickel coated aluminum, and determine process requirements for plating XDA test optic; (2) prepare and assemble plating equipment required to process a demonstration optic; (3) characterize mandrels, replicas and test samples for residual stress, surface contamination and surface roughness and figure using equipment at MSFC and; (4) provide technical expertise in establishing the processes, procedures, supplies and equipment needed to process the XDA test optics.

Engelhaupt, Darell↗

Disentangling Centrality Bias and Final-State Effects in the Production of High-𝑝 𝑇 Neutral Pions Using Direct Photon in 𝑑+Au Collisions at $\sqrt{s_{NN}}$ = 200 GeV

Here, PHENIX presents a simultaneous measurement of the production of direct 𝛾 and 𝜋 0 in 𝑑 + Au collisions at $\sqrt{s_{NN}}$ = 200 GeV over a 𝑝 𝑇 range of 7.5 to 18 GeV/𝑐 for different event samples selected by event activity, i.e., charged-particle multiplicity detected at forward rapidity. Direct-photon yields are used to empirically estimate the contribution of hard-scattering processes in the different event samples. Using this estimate, the average nuclear-modification factor, 𝑅$^{𝜋^0}_{dAu,EXP}$, is 0.925 ± 0.023⁢(stat) ± 0.15⁢(scale), consistent with unity for minimum-bias (MB) 𝑑+Au collisions. For event classes with low and moderate event activity, 𝑅$^{𝜋^0}_{dAu,EXP}$ is consistent with the MB value within 5% uncertainty. This result confirms that the previously observed enhancement of high-𝑝 𝑇 𝜋 0 production found in small-system collisions with low event activity is a result of a bias in interpreting event activity within the Glauber framework. In contrast, for the top 5% of events with the highest event activity, 𝑅$^{𝜋^0}_{dAu,EXP}$ is suppressed by 20% relative to the MB value with a significance of 4.5⁢𝜎, which may be due to final-state effects. This suppression corresponds to a 𝑝 𝑇 shift of 𝛿⁢𝑝 𝑇 = 0.213 ± 0.055 Gev/𝑐 at 9 Gev/𝑐.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Mass Spectrometry Sample Submission Portal

Each step in the scientific process generates contextual information about the data that is important to consider when performing data integration, developing models of biological process, or training AI models. We will develop a flexible, template-driven tool that will log biological samples, capture metadata about those samples, and track the type(s) of analysis being performed by researchers providing samples for analysis by mass spectrometry.

97 MATHEMATICS AND COMPUTING↗

In-house welding studies supporting the prelaunch assessment of the STS-6 main engines

Welding studies were undertaken as a result of problems with the Challenger engines. The process used to perform these welds on heat exchanger coils, and sample test data, are described. Recommendations for process improvement are included. Effort to simulate problem welds, as well as good welds, test data, and conclusions for the high pressure fuel turbopump are also are discussed.

Hawkins, L. L.↗

Human Host Cellular Response to HCoV-229E Infection Proteomics (ACS-JM-DP2)

The purpose of this experiment was to evaluate the human host cellular response to wild-type Human coronavirus strain 229E (HCoV-229E) infection. Sample data was obtained for mock and infected immortalized human lung epithelial cells (A549) (MOI 5) nuclear extracts, immortalized human lung fibroblasts cells (MRC5) (MOI5) nuclear extracts, and primary human airway epithelial (HAE) (MOI 3) cells from lung tissue and processed for proteome analysis. Processed datasets are openly accessible from the download button and contain secondary processed proteomic results files and supporting metadata materials. Experimental proteomics samples were prepared using Limited Proteolysis (LiP) methods for Label-free quantification (LFQ) and global proteomic evaluation. Sample data was acquired using a Q-Exactive HF-X mass spectrometer and was processed and compiled using MaxQuant software (v.1.6.17.0). Processed proteomic data downloads include a sample naming key, processed MaxQuant results/parameters, and protein annotated relative abundance files. See corresponding primary data accessions below and Viral Experiment LiP Analysis source code supporting data transparency and reuse. Experimental transcriptomics samples were collected in parallel and processed for RNA sequencing (RNA-Seq) as summarized under ACS-DP1 (https://data.pnnl.gov/group/nodes/dataset/34069).

59 BASIC BIOLOGICAL SCIENCES↗

Analog-To-Digital Converter For Sum-Of-Squares Measurements

Analog-to-digital converter (ADC) circuit designed as part of larger circuit intended to measure root-mean-square current on 20-kHz powerline. Provides digital output of 11 bits of data plus 1-bit overflow signal at sampling rate of 4 MHz. Output processed by multiplying-and-accumulating circuitry to obtain sum of squares and digitized current samples accumulated during preset number of consecutive sampling periods. Used to digitize current samples from ADC directly as alternative or auxiliary output. Notable features include low power and fast conversion.

Osborn, Stephen H.↗

UT-GOM2-2 Preliminary Report: Terrebonne Basin Northern Gulf of Mexico, 30 July-28 September 2023

In the summer and fall of 2023, the Gulf of Mexico Deepwater Hydrate Coring Expedition (UT-GOM2-2) drilled, cored, made downhole measurements, and analyzed samples from the seafloor to the base of the gas hydrate stability zone in one location (Site H, WR313) in the Terrebonne basin, deepwater Gulf of Mexico. Analyses of data and samples from the expedition will inform biological, geochemical, and geomechanical models to constrain the role of gas hydrates in the carbon cycle and the potential for gas hydrates as an energy resource. Pressure and conventional cores were collected continuously to a depth of 155.1 meters below the seafloor (mbsf). At deeper depths, cores were taken periodically from hydrate-bearing sands and their bounding muds to a total depth of 861.3 mbsf. 162.6 m of conventional core and 54.8 m of pressure core were obtained. Twelve temperature measurements were made between 27.1 and 144.5 mbsf to determine the geothermal gradient. At the seafloor, more than 4 m of sandy silt of unknown origin was encountered. Beneath this sand, to a depth of ~200 mbsf, the section was composed of interbedded mud and biogenic carbonate ooze. The biogenic ooze correlated to low density and high porosity intervals observed in the previously acquired logging while drilling (LWD) data and as measured. Calcareous nannofossil biostratigraphy constrains the entire record to the Pleistocene (< 0.91 million years) with a pronounced increase in sedimentation rate with depth. Beneath 200 mbsf, the section was predominantly composed of mud with two thicker, hydrate-bearing coarse-grained intervals, which are commonly known as the Blue and Orange sands. The dissolved gas concentration was quantified from pressure cores. In the shallow section, dissolved methane concentration increased below the sulfate-methane transition zone (SMTZ) and reaches saturation (the limit of solubility for methane) at 147 mbsf. Gas expansion was very common in conventional and depressurized pressure (conventionalized) cores below the SMTZ. At deeper depths, the methane concentration within muds bounding the Blue and Orange reservoirs was generally found to be less than saturation. The dissolved and hydrate gas composition is consistent with a microbial source, containing greater than 99.99% methane and only trace concentrations of ethane, propane, and butane. The methane to ethane ratio (C 1 /C 2 ) and the methane to ethane plus propane (C 1 /(C 2 +C 3 )) decrease with depth down to at least 678 mbsf, mainly driven by the increase in ethane with depth. It is unclear if this trend continues through the Orange sand interval. The δ 13 C isotopic signature of methane ranges between -69.9 and -78.5 ‰ Vienna Pee Dee Belemnite (VPDB). Pressure core recovery of all sandy intervals was poor. However, pressure core logs of the Orange sand show intervals of low density and high velocity, which are indicative of high hydrate saturation. One core from within the Orange sand was composed of interbedded graded sandy silt and mud. The sandy silts from this core are composed of mainly quartz and feldspar with some lithics. Most of the recovered pressure core samples are maintained at near in-situ pressure and temperature (within the hydrate stability field) at the University of Texas Pressure Core Center awaiting analysis. In the shallow section, samples will be used to determine the flux of organic carbon through the basin system, find the rate at which that carbon was consumed, and understand the microbial population responsible for these processes. In the deeper section, samples from in and around the hydrate reservoirs will be used to determine the petrophysical properties of the reservoir and bounding seals in these systems.

03 NATURAL GAS↗

Expedition UT-GOM2-2 Site H

Pressure and conventional cores were collected at Site H of the Walker Ridge Protracted Area Block 313 in the Terrebonne Basin, deepwater Gulf of America (Gulf of Mexico) during the University of Texas (UT) Deepwater Hydrate Coring Expedition (UT-GOM2-2). Pressure and conventional cores were collected continuously to a depth of 155.1 meters below the seafloor (mbsf). At deeper depths, cores were taken periodically from hydrate-bearing sands and their bounding muds to a total depth of 861.3 mbsf. 162.6 m of conventional core and 54.8 m of pressure core were recovered. Twelve temperature measurements were made between 27.1 and 144.5 mbsf to determine the geothermal gradient. At the seafloor, more than 4 m of sandy silt of unknown origin was encountered. Beneath this sand, to a depth of about 200 mbsf, the section was composed of interbedded mud and biogenic carbonate ooze. The ooze correlated to low density and high porosity intervals observed in the previously acquired logging while drilling (LWD) data and as measured. These ooze intervals also correspond to lighter sediment color, increased Ca content based on X-ray florescence (XRF) core scanning, and increased calcareous nannofossil abundance. Calcareous nannofossil biostratigraphy constrains the entire record to the Pleistocene (< 0.91 million years), with a pronounced increase in sedimentation rate with depth. Below 200 mbsf, the section was predominantly composed of mud with two thicker, hydrate-bearing coarse-grained intervals, which are commonly known as the Blue and Orange sands. The dissolved gas concentration was quantified from pressure cores. In the shallow section, dissolved methane concentration increased below the sulfate-methane transition zone (SMTZ) and reaches saturation (the limit of solubility for methane) at 147 mbsf. Gas expansion was very common in conventional and depressurized pressure (conventionalized) cores below the SMTZ. At deeper depths, the methane concentration within muds bounding the Blue and Orange reservoirs was generally found to be less than saturation. The dissolved and hydrate gas composition is consistent with a microbial source, containing greater than 99.99% methane and only trace concentrations of ethane, propane, and butane. The methane to ethane ratio (C1 /C2 ) and the methane to ethane plus propane (C1 /(C2 +C3 )) decrease with depth down to at least 678 mbsf, mainly driven by the increase in ethane with depth. It is unclear if this trend continues through the Orange sand interval. The δ13C isotopic signature of methane ranges between -69.9 and -78.5 ‰ relative to the Vienna Pee Dee Belemnite (VPDB) standard. Pressure core recovery in sandy intervals was poor. However, pressure core logs of the Orange sand show intervals of low density and high velocity, which are indicative of high hydrate saturation. One pressure core was degassed and the average hydrate saturation in the core was determined to be 24%. One core from within the Orange sand was composed of interbedded graded sandy silt and mud. The sandy silts from this core are composed of mainly quartz and feldspar with some lithics. Most of the recovered pressure core samples are maintained at near in-situ pressure and temperature (within the hydrate stability field) at the University of Texas Pressure Core Center awaiting analysis. In the shallow section, samples will be used to determine the flux of organic carbon through the basin system, find the rate at which that carbon was consumed, and understand the microbial population responsible for these processes. In the deeper section, samples from in and around the hydrate reservoirs will be used to determine the petrophysical properties of the reservoir and bounding seals in these systems.

03 NATURAL GAS↗

Sample Acquisition and Analytical Chemistry Challenges to Verifying Compliance to Aviators Breathing Oxygen (ABO) Purity Specification

NASA has been developing and testing two different types of oxygen separation systems. One type of oxygen separation system uses pressure swing technology, the other type uses a solid electrolyte electrochemical oxygen separation cell. Both development systems have been subjected to long term testing, and performance testing under a variety of environmental and operational conditions. Testing these two systems revealed that measuring the product purity of oxygen, and determining if an oxygen separation device meets Aviator's Breathing Oxygen (ABO) specifications is a subtle and sometimes difficult analytical chemistry job. Verifying product purity of cryogenically produced oxygen presents a different set of analytical chemistry challenges. This presentation will describe some of the sample acquisition and analytical chemistry challenges presented by verifying oxygen produced by an oxygen separator - and verifying oxygen produced by cryogenic separation processes. The primary contaminant that causes gas samples to fail to meet ABO requirements is water. The maximum amount of water vapor allowed is 7 ppmv. The principal challenge of verifying oxygen produced by an oxygen separator is that it is produced relatively slowly, and at comparatively low temperatures. A short term failure that occurs for just a few minutes in the course of a 1 week run could cause an entire tank to be rejected. Continuous monitoring of oxygen purity and water vapor could identify problems as soon as they occur. Long term oxygen separator tests were instrumented with an oxygen analyzer and with an hygrometer: a GE Moisture Monitor Series 35. This hygrometer uses an aluminum oxide sensor. The user's manual does not report this, but long term exposure to pure oxygen causes the aluminum oxide sensor head to bias dry. Oxygen product that exceeded the 7 ppm specification was improperly accepted, because the sensor had biased. The bias is permanent - exposure to air does not cause the sensor to return to its original response - but the bias can be accounted for by recalibrating the sensor. After this issue was found, continuous measurements of water vapor in the oxygen product were made using an FTIR. The FTIR cell is relatively large, so response time is slow - but moisture measurements were repeatable and accurate. Verifying ABO compliance for oxygen produced by commercial cryogenic processes has a different set of sample acquisition and analytical chemistry challenges. Customers want analytical chemists to conserve as much as possible. Hygrometers are not exposed to hours of continuous flow of oxygen, so they don't bias, but small amounts of contamination in valves can cause a "fail". K bottles are periodically cleaned and recertified - after cleaning residual moisture can cause a "fail". Operators let bottle pressure drop to room pressure, introduce outside air into the bottle, and the subsequent fill will "fail". Outside storage of K‐bottles has allowed enough in‐leakage, so contents will "fail".

Graf, John↗

The Astromaterials X-Ray Computed Tomography Laboratory at Johnson Space Center

The Astromaterials Acquisition and Curation Office at NASA's Johnson Space Center (hereafter JSC curation) is the past, present, and future home of all of NASA's astromaterials sample collections. JSC curation currently houses all or part of nine different sample collections: (1) Apollo samples (1969), (2) Lunar samples (1972), (3) Antarctic meteorites (1976), (4) Cosmic Dust particles (1981), (5) Microparticle Impact Collection (1985), (6) Genesis solar wind atoms (2004); (7) Stardust comet Wild-2 particles (2006), (8) Stardust interstellar particles (2006), and (9) Hayabusa asteroid Itokawa particles (2010). Each sample collection is housed in a dedicated clean room, or suite of clean rooms, that is tailored to the requirements of that sample collection. Our primary goals are to maintain the long-term integrity of the samples and ensure that the samples are distributed for scientific study in a fair, timely, and responsible manner, thus maximizing the return on each sample. Part of the curation process is planning for the future, and we also perform fundamental research in advanced curation initiatives. Advanced Curation is tasked with developing procedures, technology, and data sets necessary for curating new types of sample collections, or getting new results from existing sample collections [2]. We are (and have been) planning for future curation, including cold curation, extended curation of ices and volatiles, curation of samples with special chemical considerations such as perchlorate-rich samples, and curation of organically- and biologically-sensitive samples. As part of these advanced curation efforts we are augmenting our analytical facilities as well. A micro X-Ray computed tomography (micro-XCT) laboratory dedicated to the study of astromaterials will be coming online this spring within the JSC Curation office, and we plan to add additional facilities that will enable nondestructive (or minimally-destructive) analyses of astromaterials in the near future (micro-XRF, confocal imaging Raman Spectroscopy). These facilities will be available to: (1) develop sample handling and storage techniques for future sample return missions; (2) be utilized by PET for future sample return missions; (3) be used for retroactive PET (Positron Emission Tomography)-style analyses of our existing collections; and (4) for periodic assessments of the existing sample collections. Here we describe the new micro-XCT system, as well as some of the ongoing or anticipated applications of the instrument.

Zeigler, R. A.↗

The Astromaterials X-Ray Computed Tomography Laboratory at Johnson Space Center

The Astromaterials Acquisition and Curation Office at NASA's Johnson Space Center (hereafter JSC curation) is the past, present, and future home of all of NASA's astromaterials sample collections. JSC curation currently houses all or part of nine different sample collections: (1) Apollo samples (1969), (2) Lunar samples (1972), (3) Antarctic meteorites (1976), (4) Cosmic Dust particles (1981), (5) Microparticle Impact Collection (1985), (6) Genesis solar wind atoms (2004); (7) Stardust comet Wild-2 particles (2006), (8) Stardust interstellar particles (2006), and (9) Hayabusa asteroid Itokawa particles (2010). Each sample collection is housed in a dedicated clean room, or suite of clean rooms, that is tailored to the requirements of that sample collection. Our primary goals are to maintain the long-term integrity of the samples and ensure that the samples are distributed for scientific study in a fair, timely, and responsible manner, thus maximizing the return on each sample. Part of the curation process is planning for the future, and we also perform fundamental research in advanced curation initiatives. Advanced Curation is tasked with developing procedures, technology, and data sets necessary for curating new types of sample collections, or getting new results from existing sample collections [2]. We are (and have been) planning for future curation, including cold curation, extended curation of ices and volatiles, curation of samples with special chemical considerations such as perchlorate-rich samples, and curation of organically- and biologically-sensitive samples. As part of these advanced curation efforts we are augmenting our analytical facilities as well. A micro X-Ray computed tomography (micro-XCT) laboratory dedicated to the study of astromaterials will be coming online this spring within the JSC Curation office, and we plan to add additional facilities that will enable nondestructive (or minimally-destructive) analyses of astromaterials in the near future (micro-XRF, confocal imaging Raman Spectroscopy). These facilities will be available to: (1) develop sample handling and storage techniques for future sample return missions; (2) be utilized by PET for future sample return missions; (3) be used for retroactive PET (Positron Emission Tomography)-style analyses of our existing collections; and (4) for periodic assessments of the existing sample collections. Here we describe the new micro-XCT system, as well as some of the ongoing or anticipated applications of the instrument.

Zeigler, R. A.↗