Search NASA⌕ Search

SEARCH · Search NASA

Results for “sensitivity methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 991 records · Page 55

Proposal of an environmental performance index to assess solid waste treatment technologies

Highlights: Black-Right-Pointing-Pointer Proposal of a new concept in waste management: Cleaner Treatment. Black-Right-Pointing-Pointer Development of an index to assess quantitatively waste treatment technologies. Black-Right-Pointing-Pointer Delphi Method was carried out so as to define environmental indicators. Black-Right-Pointing-Pointer Environmental performance evaluation of waste-to-energy plants. - Abstract: Although the concern with sustainable development and environment protection has considerably grown in the last years it is noted that the majority of decision making models and tools are still either excessively tied to economic aspects or geared to the production process. Moreover, existing models focus on the priority steps of solid waste management, beyond waste energy recovery and disposal. So, in order to help the lack of models and tools aiming at the waste treatment and final disposal, a new concept is proposed: the Cleaner Treatment, which is based on the Cleaner Production principles. This paper focuses on the development and validation of the Cleaner Treatment Index (CTI), to assess environmental performance of waste treatment technologies based on the Cleaner Treatment concept. The index is formed by aggregation (summation or product) of several indicators that consists in operational parameters. The weights of the indicator were established by Delphi Method and Brazilian Environmental Laws. In addition, sensitivity analyses were carried out comparing both aggregation methods. Finally, index validation was carried out by applying the CTI to 10 waste-to-energy plants data. From sensitivity analysis and validation results it is possible to infer that summation model is the most suitable aggregation method. For summation method, CTI results were superior to 0.5 (in a scale from 0 to 1) for most facilities evaluated. So, this study demonstrates that CTI is a simple and robust tool to assess and compare the environmental performance of different treatment plants being an excellent quantitative tool to support Cleaner Treatment implementation.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Sensitivity of geophysical techniques for monitoring secondary CO 2 storage plumes

For geologic carbon storage, the ability to detect secondary CO 2 plumes—defined as those CO 2 plumes accumulating outside the intended storage reservoir—is fundamental to preventing unexpected CO 2 migration into groundwater resources and for risk and liability management. Understanding the sensitivity of various geophysical methods to secondary plumes is crucial for designing cost-effective monitoring schemes. We use several modeling scenarios to demonstrate the process of assessing sensitivities and detection thresholds of three primary geophysical techniques—surface seismic, borehole-to-surface electromagnetic (EM), and surface and borehole gravity—for early detection of secondary CO 2 plumes in the post-injection phase. While seismic reflection methods are often considered in monitoring strategies to track the evolution of CO 2 plumes, they are also the most expensive. Due to cost considerations, especially for long-term post-injection monitoring, other techniques complement seismic monitoring when designing an adaptive monitoring network. Borehole-to-surface EM or surface gravity surveys are feasible for time-lapse monitoring of deep secondary CO 2 plumes. Furthermore, these surveys could be carried at intervals defined by site-specific conditions. If time-lapse EM and/or gravity surveys detect any signal responses beyond the expected change, it would trigger a need for the higher resolution seismic survey.

58 GEOSCIENCES↗

Determination of Strain Rate Sensitivity of Micro-struts Manufactured Using the Selective Laser Melting Method

Micro-lattice structures manufactured using the selective laser melting (SLM) process provides the opportunity to realize optimal cellular materials for impact energy absorption. In this paper, strain rate-dependent material properties are measured for stainless steel 316L SLM micro-lattice struts in the strain rate range of 10{sup −3} to 6000 s{sup −1}. At high strain rates, a novel version of the split Hopkinson Bar has been developed. Strain rate-dependent materials data have been used in Cowper–Symonds material model, and the scope and limit of this model in the context of SLM struts have been discussed. Strain rate material data and the Cowper–Symonds model have been applied to the finite element analysis of a micro-lattice block subjected to drop weight impact loading. The model output has been compared to experimental results, and it has been shown that the increase in crush stress due to impact loading is mainly the result of strain rate material behavior. Hence, a systematic methodology has been developed to investigate the impact energy absorption of a micro-lattice structure manufactured using additive layer manufacture (SLM). This methodology can be extended to other micro-lattice materials and configurations, and to other impact conditions.

36 MATERIALS SCIENCE↗

Optimization of the first order gradiometer for small sample magnetization measurements using pulse integrating magnetometer

In the paper we present an analytical calculation method for determination of the sensitivity of a pulse field magnetometer working with a first order gradiometer. Our considerations here are especially focused on a case of magnetic moment measurements of very small samples. Derived in the work analytical equations allow for a quick estimation of the magnetometer's sensitivity and give also the way to its calibration using the sample simulation coil method. On the base of the given in the paper calculations we designed and constructed a simple homemade magnetometer and performed its sensitivity calibration.

36 MATERIALS SCIENCE↗

TU-C-BRE-10: A Streamlined Approach to EPID Transit Dosimetry

Purpose: To investigate the feasibility of a simple and efficient transit dosimetry method using the electronic portal imaging device (EPID) for dose delivery error detection and prevention. Methods: In the proposed method, 2D reference transit images are generated for comparison with online images acquired during treatment. Reference transit images are generated by convolving through-air EPID measurements of each field with pixel-specific kernels selected from a library of pre-calculated Monte Carlo pencil kernels of varying radiological thickness. The kernel used for each pixel is selected based on the calculated radiological thickness of the patient along a line joining the pixel and the virtual source. The accuracy of the technique was evaluated in flat homogeneous and heterogeneous plastic water phantoms, a heterogeneous cylindrical phantom, and an anthropomorphic head phantom. Gamma criteria of 3%/3 mm was used to quantify the accuracy of the technique for the various cases. Results: An average of 99.9% and 99.7% of the points in the comparison between the measured and predicted images passed a 3%/3mm gamma for the homogeneous and heterogeneous plastic water phantoms, respectively. 97.1% of the points passed for the analysis of the heterogeneous cylindrical phantom. For the anthropomorphic head phantom, an average of 97.8% of points passed the 3%/3mm gamma criteria for all field sizes. Failures were observed primarily in areas of drastic thickness or material changes and at the edges of the fields. Conclusion: The data suggest that the proposed transit dosimetry method is a feasible approach to in vivo dose monitoring. Future research efforts could include implementation for more complex fields and sensitivity testing of the method to setup errors and changes in anatomy. Oncology Data Systems provided partial funding support but did not participate in the collection or analysis of data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Plastic work constrained elastoplastic topology optimization

An elastoplastic topology optimization framework for limiting plastic work generation while maximizing stiffness is presented. The kinematics and constitutive model are based on finite strain linear isotropic hardening plasticity, and the balance laws are solved using a total Lagrangian finite element formulation. Aggregation of the specific plastic work combined with an adaptive normalization scheme efficiently constrains the maximum specific plastic work. The optimization problem is regularized using an augmented partial differential equation filter, and is solved by the method of moving asymptotes where path-dependent sensitivities are derived using the adjoint method. The numerical examples show a clear dependence on the optimized maximum stiffness structures for different levels of constrained specific plastic work. It is also shown that due to the history dependency of the plasticity, the load path significantly influences the structural performance and optimized topology.

42 ENGINEERING↗

Online Monitoring System for Concrete Structures Affected by Alkali-Silica Reaction

This report presents a comprehensive study of developing ultrasonic wave and acoustic emission (AE) techniques for long-term monitoring of alkali-silica reaction (ASR) development in concrete. Small, medium, and full-scale concrete specimens were cast, conditioned, and monitored for various periods, from at least one year to 2.4 years. The reactive concrete specimens contain coarse or fine reactive aggregates to study the effects of different types of reactive aggregates. Confinements were also designed to simulate the 2-dimensional confinement effects of reinforcement in the shield building of nuclear power plants. The concrete specimens were stored in a environmental chamber with high humidity and high temperature to accelerate the ASR development. The ultrasonic monitoring data shows high sensitivity to ASR development and could detect cracking initiation well before visible surface cracks occurred. However, the linear ultrasonic analysis based on wave velocity is strongly affected by temperature variation. Therefore, a nonlinear ultrasonic method was proposed to measure thermally induced nonlinear acoustic responses of concrete (thermal modulation of ultrasonic wave). The measured nonlinear acoustic parameter shows a high correlation with ASR expansion across specimens with different reactive aggregates and confinement conditions. The same conclusion was obtained from nonlinear resonance tests on small concrete prisms. Compared to the linear acoustic methods, the nonlinear tests show high sensitivities to ASR damage from internal microcracking initiation at the early stage to visible cracks at the late stage of ASR. The attributes of the thermal modulation of nonlinear ultrasonic method include high sensitivity, immunity to temperature effects, and strong correlation with ASR expansion, which demonstrate great potentials of the nonlinear ultrasonic method for diagnosis of ASR damage and prediction of concrete deterioration process. Acoustic emission is a passive sensing technique for damage assessment, and access to only one surface is needed even for thick and heavily reinforced elements such as the walls utilized for nuclear shield building. Additionally, relatively few sensors are required to monitor the progression of the damage process. Results indicate that the AE data can be related to the damage rating index, which is a petrography-based means of assessing damage due to ASR in reinforced concrete. Furthermore, AE is capable of detecting ASR damage long before surface cracking is visually noticeable. Boundary conditions play in important role in the progression of ASR damage and differences in boundary conditions are reflected in the AE data. Entropy based data assessment methods provide a means to assess the damage state, and convolutional neural network based data assessment provided a means to assess the damage state in real-time. Results indicate that artificial neural network models may be used as a means to predict volumetric expansion based on AE data.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Diagnosing the sensitivity of grounding-line flux to changes in sub-ice-shelf melting

Abstract. Using a numerical ice flow model, we study changes in ice shelf buttressing and grounding-line flux due to localized ice thickness perturbations, a proxy for localized changes in sub-ice-shelf melting. From our experiments, applied to idealized (MISMIP+) and realistic (Larsen C) ice shelf domains, we identify a correlation between a locally derived buttressing number on the ice shelf, based on the first principal stress, and changes in the integrated grounding-line flux. The origin of this correlation, however, remains elusive from the perspective of a theoretical or physically based understanding. This and the fact that the correlation is generally much poorer when applied to realistic ice shelf domains motivate us to seek an alternative approach for predicting changes in grounding-line flux. We therefore propose an adjoint-based method for calculating the sensitivity of the integrated grounding-line flux to local changes in ice shelf geometry. We show that the adjoint-based sensitivity is identical to that deduced from pointwise, diagnostic model perturbation experiments. Based on its much wider applicability and the significant computational savings, we propose that the adjoint-based method is ideally suited for assessing grounding-line flux sensitivity to changes in sub-ice-shelf melting.

54 ENVIRONMENTAL SCIENCES↗

Multi-stage preconditioners for thermal–compositional–reactive flow in porous media

We present a family of multi-stage preconditioners for coupled thermal-compositional-reactive reservoir simulation problems. The most common preconditioner used in industrial practice, the Constrained Pressure Residual (CPR) method, was designed for isothermal models and does not offer a specific strategy for the energy equation. For thermal simulations, inadequate treatment of the temperature unknown can cause severe conver-gence degradation. When strong thermal diffusion is present, the energy equation exhibits significant elliptic behavior that cannot be accurately corrected by CPR's second stage. In this work, we use Schur-complement decompositions to extract a temperature subsystem and apply an Algebraic MultiGrid (AMG) approximation as an additional preconditioning stage to improve the treatment of the energy equation. We present results for several two-dimensional hot air injection problems using an extra heavy oil, including challenging reactive In-Situ Combustion (ISC) cases. We show improved performance and robustness across different thermal regimes, from advection dominated (high Péclet number) to diffusion dominated (low Péclet number). The number of linear iterations is reduced by 40–85% compared to standard CPR for both homogeneous and heterogeneous media, and the new methods exhibit almost no sensitivity to the thermal regime.

42 ENGINEERING↗

Evaluation of Different Soil Carbon Determination Methods

Determining soil carbon (C) with high precision is an essential requisite for the success of the terrestrial C sequestration program. The informed choice of management practices for different terrestrial ecosystems rests upon accurately measuring the potential for C sequestration. Numerous methods are available for assessing soil C. Chemical analysis of field-collected samples using a dry combustion method is regarded as the standard method. However, conventional sampling of soil and their subsequent chemical analysis is expensive and time consuming. Furthermore, these methods are not sufficiently sensitive to identify small changes over time in response to alterations inmanagement practices or changes in land use. Presently, several different in situ analytic methods are being developed purportedly offering increased accuracy, precision and cost-effectiveness over traditional ex situ methods. We consider that, at this stage, a comparative discussion of different soil C determination methods will improve the understanding needed to develop a standard protocol.

54 ENVIRONMENTAL SCIENCES↗

Optimal Placement of Dynamic Var Sources by Using Empirical Controllability Covariance

In this paper, the empirical controllability covariance (ECC), which is calculated around the considered operating condition of a power system, is applied to quantify the degree of controllability of system voltages under specific dynamic var source locations. An optimal dynamic var source placement method addressing fault-induced delayed voltage recovery (FIDVR) issues is further formulated as an optimization problem that maximizes the determinant of ECC. The optimization problem is effectively solved by the NOMAD solver, which implements the mesh adaptive direct search algorithm. The proposed method is tested on an NPCC 140-bus system and the results show that the proposed method with fault specified ECC can solve the FIDVR issue caused by the most severe contingency with fewer dynamic var sources than the voltage sensitivity index (VSI)-based method. The proposed method with fault unspecified ECC does not depend on the settings of the contingency and can address more FIDVR issues than the VSI method when placing the same number of SVCs under different fault durations. It is also shown that the proposed method can help mitigate voltage collapse.

24 POWER TRANSMISSION AND DISTRIBUTION↗

BIGHORN Computational Fluid Dynamics Theory, Methodology, and Code Verification & Validation Benchmark Problems

This document presents the theoretical background for a hybrid finite-element / finite-volume fluid flow solver, namely BIGHORN, based on the Multiphysics Object Oriented Simulation Environment (MOOSE) computational framework developed at the Idaho National Laboratory (INL). An overview of the numerical methods used in BIGHORN are discussed and followed by a presentation of the formulation details. The document begins with the governing equations for the compressible fluid flow, with an outline of the requisite constitutive relations. A second-order finite volume method used for solving the compressible fluid flow problems is presented next. A Pressure-Corrected Implicit Continuous-fluid Eulerian (PCICE) formulation for time integration is also presented. The multi-fluid formulation is being developed. Although multi-fluid is not fully-developed, BIGHORN has been designed to handle multi-fluid problems. Due to the flexibility in the underlying MOOSE framework, BIGHORN is quite extensible, and can accommodate both multi-species and multi-phase formulations. This document also presents a suite of verification & validation benchmark test problems for BIGHORN. The intent for this suite of problems is to provide baseline comparison data that demonstrates the performance of the BIGHORN solution methods on problems that vary in complexity from laminar to turbulent flows. Wherever possible, some form of solution verification has been attempted to identify sensitivities in the solution methods, and suggest best practices when using BIGHORN.

97 MATHEMATICS AND COMPUTING↗

Bi-harmonic cantilever design for improved measurement sensitivity in tapping-mode atomic force microscopy

This paper presents a method and cantilever design for improving the mechanical measurement sensitivity in the atomic force microscopy (AFM) tapping mode. The method uses two harmonics in the drive signal to generate a bi-harmonic tapping trajectory. Mathematical analysis demonstrates that the wide-valley bi-harmonic tapping trajectory is as much as 70% more sensitive to changes in the sample topography than the standard single-harmonic trajectory typically used. Although standard AFM cantilevers can be driven in the bi-harmonic tapping trajectory, they require large forcing at the second harmonic. A design is presented for a bi-harmonic cantilever that has a second resonant mode at twice its first resonant mode, thereby capable of generating bi-harmonic trajectories with small forcing signals. Bi-harmonic cantilevers are fabricated by milling a small cantilever on the interior of a standard cantilever probe using a focused ion beam. Bi-harmonic drive signals are derived for standard cantilevers and bi-harmonic cantilevers. Experimental results demonstrate better than 30% improvement in measurement sensitivity using the bi-harmonic cantilever. Images obtained through bi-harmonic tapping exhibit improved sharpness and surface tracking, especially at high scan speeds and low force fields.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Lung deformations and radiation-induced regional lung collapse in patients treated with stereotactic body radiation therapy

Purpose: To differentiate radiation-induced fibrosis from regional lung collapse outside of the high dose region in patients treated with stereotactic body radiation therapy (SBRT) for lung tumors. Methods: Lung deformation maps were computed from pre-treatment and post-treatment computed tomography (CT) scans using a point-to-point translation method. Fifty anatomical landmarks inside the lung (vessel or airway branches) were matched on planning and follow-up scans for the computation process. Two methods using the deformation maps were developed to differentiate regional lung collapse from fibrosis: vector field and Jacobian methods. A total of 40 planning and follow-ups CT scans were analyzed for 20 lung SBRT patients. Results: Regional lung collapse was detected in 15 patients (75%) using the vector field method, in ten patients (50%) using the Jacobian method, and in 12 patients (60%) by radiologists. In terms of sensitivity and specificity the Jacobian method performed better. Only weak correlations were observed between the dose to the proximal airways and the occurrence of regional lung collapse. Conclusions: The authors presented and evaluated two novel methods using anatomical lung deformations to investigate lung collapse and fibrosis caused by SBRT treatment. Differentiation of these distinct physiological mechanisms beyond what is usually labeled “fibrosis” is necessary for accurate modeling of lung SBRT-induced injuries. With the help of better models, it becomes possible to expand the therapeutic benefits of SBRT to a larger population of lung patients with large or centrally located tumors that were previously considered ineligible.

60 APPLIED LIFE SCIENCES↗

he Impact of Primary Marine Aerosol on Atmospheric Chemistry, Radiation and Climate: A CCSM Model Development Study

This project examined the potential large-scale influence of marine aerosol cycling on atmospheric chemistry, physics and radiative transfer. Measurements indicate that the size-dependent generation of marine aerosols by wind waves at the ocean surface and the subsequent production and cycling of halogen-radicals are important but poorly constrained processes that influence climate regionally and globally. A reliable capacity to examine the role of marine aerosol in the global-scale atmospheric system requires that the important size-resolved chemical processes be treated explicitly. But the treatment of multiphase chemistry across the breadth of chemical scenarios encountered throughout the atmosphere is sensitive to the initial conditions and the precision of the solution method. This study examined this sensitivity, constrained it using high-resolution laboratory and field measurements, and deployed it in a coupled chemical-microphysical 3-D atmosphere model.

54 ENVIRONMENTAL SCIENCES↗

2D Graphene Sheets as a Sensing Material for the Electroanalysis of Zileuton

Zileuton (ZLT) is an active oral inhibitor of enzyme 5-lipoxygenase, and long-term intake and overdose of ZLT cause adverse effects, leading to critical conditions in patients. This is a well-recognized issue that necessitates a better approach for ZLT sensing. Given the increasing interest in ZLT sensing and the limitations of previous techniques, there is a need for a highly sensitive, robust, and fast operation method that is inexpensive and easy to use. Thus, for the sensitive detection and determination of ZLT, an electrochemical sensor based on graphene was fabricated. Graphene has excellent properties, such as high surface area, low toxicity, conductivity, and electroactive conjugation with biomolecules, making it suitable for sensing. The electrocatalytic property of graphene promotes the redox-coupled reaction of ZLT. Electrochemical investigation of the modifier was carried out by cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). An optimization and analysis of the influence of different parameters on the electrochemical behavior of ZLT were carried out using the CV approach. The scan rate study aided in exploring the physicochemical properties of the electrode process, and two electrons with two protons were found to be involved in the electrooxidation of ZLT. The fabricated sensor showed a wide range of linearity with ZLT, from 0.3 µM to 100.0 µM, and the detection limit was evaluated as 0.03 µM under optimized conditions. The analysis of spiked urine samples, with good recovery values for percent RSD, provided support for the efficiency and applicability of the developed electrode.

2D Material↗

Analytical Validation of Accelerator Mass Spectrometry for Pharmaceutical Development: the Measurement of Carbon-14 Isotope Ratio.

Accelerator mass spectrometry (AMS) is an isotope based measurement technology that utilizes carbon-14 labeled compounds in the pharmaceutical development process to measure compounds at very low concentrations, empowers microdosing as an investigational tool, and extends the utility of {sup 14}C labeled compounds to dramatically lower levels. It is a form of isotope ratio mass spectrometry that can provide either measurements of total compound equivalents or, when coupled to separation technology such as chromatography, quantitation of specific compounds. The properties of AMS as a measurement technique are investigated here, and the parameters of method validation are shown. AMS, independent of any separation technique to which it may be coupled, is shown to be accurate, linear, precise, and robust. As the sensitivity and universality of AMS is constantly being explored and expanded, this work underpins many areas of pharmaceutical development including drug metabolism as well as absorption, distribution and excretion of pharmaceutical compounds as a fundamental step in drug development. The validation parameters for pharmaceutical analyses were examined for the accelerator mass spectrometry measurement of {sup 14}C/C ratio, independent of chemical separation procedures. The isotope ratio measurement was specific (owing to the {sup 14}C label), stable across samples storage conditions for at least one year, linear over 4 orders of magnitude with an analytical range from one tenth Modern to at least 2000 Modern (instrument specific). Further, accuracy was excellent between 1 and 3 percent while precision expressed as coefficient of variation is between 1 and 6% determined primarily by radiocarbon content and the time spent analyzing a sample. Sensitivity, expressed as LOD and LLOQ was 1 and 10 attomoles of carbon-14 (which can be expressed as compound equivalents) and for a typical small molecule labeled at 10% incorporated with {sup 14}C corresponds to 30 fg equivalents. AMS provides an sensitive, accurate and precise method of measuring drug compounds in biological matrices.

07 ISOTOPE AND RADIATION SOURCES↗

SCALE-6 Sensitivity/Uncertainty Methods and Covariance Data

Computational methods and data used for sensitivity and uncertainty analysis within the SCALE nuclear analysis code system are presented. The methodology used to calculate sensitivity coefficients and similarity coefficients and to perform nuclear data adjustment is discussed. A description is provided of the SCALE-6 covariance library based on ENDF/B-VII and other nuclear data evaluations, supplemented by 'low-fidelity' approximate covariances.

99 GENERAL AND MISCELLANEOUS↗