Search NASA⌕ Search

SEARCH · Search NASA

Results for “sensor array”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 991 records · Page 55

Towards High-Efficiency Particle Detection Using Superconducting Microwire Arrays

We present a detailed study of an 8-channel $1\times1$~mm$^{2}$ WSi superconducting microwire single photon detector (SMSPD) array exposed to 120~GeV hadron beam and 120~GeV muon beam at the CERN Super Proton Synchrotron H6 beamline. Following up on our first detailed characterization of the efficiency and response of an SMSPD fabricated on a 3~nm WSi film, we report measurements of enhanced particle detection efficiency using a sensor fabricated from a thicker 4.7~nm-thick WSi film. We also report the first SMSPD detection efficiency measurement made for muons. Measurements are enabled by a silicon tracking telescope providing 10~$\mu$m in situ spatial resolution. The results show a detection efficiency of 75\% and a time resolution of about 130~ps across pixels. These findings represent a significant advancement toward developing high-efficiency SMSPD charged particle tracking systems with simultaneous precision timing, with potential applications in future accelerator-based experiments such as the FCC-ee and Muon Collider.

Wang, Christina [Fermilab]↗

Miniature optical planar camera based on a wide-angle metasurface doublet corrected for monochromatic aberrations

Optical metasurfaces are two-dimensional arrays of nano-scatterers that modify optical wavefronts at subwavelength spatial resolution. They are poised to revolutionize optics by enabling complex low-cost systems where multiple metasurfaces are lithographically stacked and integrated with electronics. For imaging applications, metasurface stacks can perform sophisticated image corrections and can be directly integrated with image sensors. Here we demonstrate this concept with a miniature flat camera integrating a monolithic metasurface lens doublet corrected for monochromatic aberrations, and an image sensor. The doublet lens, which acts as a fisheye photographic objective, has a small f-number of 0.9, an angle-of-view larger than 60° × 60°, and operates at 850 nm wavelength with 70% focusing efficiency. The camera exhibits nearly diffraction-limited image quality, which indicates the potential of this technology in the development of optical systems for microscopy, photography, and computer vision.

47 OTHER INSTRUMENTATION↗

Microfabrication of High Resolution X-ray Magnetic Calorimeters

Metallic magnetic calorimeter (MMC) is one of the most promising x-ray detector technologies for providing the very high energy resolution needed for future astronomical x-ray imaging spectroscopy. For this purpose, we have developed micro-fabricated 5x5 arrays of MMC of which each individual pixel has excellent energy resolution as good as 3.4 eV at 6 keV x-ray. Here we report on the fabrication techniques developed to achieve good resolution and high efficiency. These include: processing of a thin insulation layer for strong magnetic coupling between the AuEr sensor film and the niobium pick-up coil; production of overhanging absorbers for enhanced efficiency of x-ray absorption; fabrication on SiN membranes to minimize the effects on energy resolution from athermal phonon loss. We have also improved the deposition of the magnetic sensor film such that the film magnetization is nearly completely that is expected from the AuEr sputter target bulk material. In addition, we have included a study of a positional sensitive design, the Hydra design, which allows thermal coupling of four absorbers to a common MMC sensor and circuit.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Sensing Service Transformer Secondary Currents using Planar Magnetic Pick-up Coils

The rapid deployment of distributed energy resources (DERs) is creating stresses on utility assets in the distribution networks. The service transformer, which is the most commonly used utility asset is often not monitored, since the cost of available sensing solutions is as high as the transformer itself. This paper presents a method to use an array of printed circuit board coils to intelligently monitor North American pole top service transformers. The approach, uses a novel, self-calibrating algorithm to infer the fixed geometry of the installation, by recording data over an extended period of time. The proposed method can enable rapid installation of a non-intrusive sensor that can be used to monitor loading levels of the distribution transformer. Furthermore, these sensors can help in planning, prognostics and advanced situational awareness for utilities.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Hadron Monitor Calibration System for NuMI

NuMI (Neutrinos at Main Injector) beamline at Fermi National Accelerator Laboratory provides neutrinos to various neutrino experiments. The hadron monitor consisting of a 5 by 5 array of ionization chambers is part of the diagnostics for the beamline. In order to calibrate the hadron monitor, a gamma source is needed. We present the status and progress of the development of the calibration system for the hadron monitor. The system based on Raspberry Pi controlled CNC system, motors, and position sensors would allow us to place the gamma source precisely to calibrate the signal gain of individual pixels. The ultimate outcome of the study is a prototype of the calibration system.

43 PARTICLE ACCELERATORS↗

Novel rotating field probe for inspection of tubes

Inspection of steam generator tubes in nuclear power plants is extremely critical for safe operation of the power plant. In the nuclear industry, steam generator tube inspection using eddy current techniques has evolved over the years from a single bobbin coil, to rotating probe coil (RPC) and array probe, in an attempt to improve the speed and reliability of inspection. The RPC probe offers the accurate spatial resolution but involves complex mechanical rotation. This paper presents a novel design of eddy current probes based on rotating fields produced by three identical coils excited by a balanced three-phase supply. The sensor thereby achieves rotating probe functionality by electronic means and eliminates the need for mechanical rotation. The field generated by the probe is largely radial that result in induced currents that flow circularly around the radial axis and rotating around the tube at a synchronous speed effectively producing induced eddy currents that are multidirectional. The probe will consequently be sensitive to cracks of all orientations in the tube wall. The finite element model (FEM) results of the rotating fields and induced currents are presented. A prototype probe is being built to validate simulation results.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Design, upgrade and characterization of the silicon photomultiplier front-end for the AMIGA detector at the Pierre Auger Observatory

AMIGA (Auger Muons and Infill for the Ground Array) is an upgrade of the Pierre Auger Observatory to complement the study of ultra-high-energy cosmic rays (UHECR) by measuring the muon content of extensive air showers (EAS). It consists of an array of 61 water Cherenkov detectors on a denser spacing in combination with underground scintillation detectors used for muon density measurement. Each detector is composed of three scintillation modules, with 10 m 2 detection area per module, buried at 2.3 m depth, resulting in a total detection area of 30 m 2 . Silicon photomultiplier sensors (SiPM) measure the amount of scintillation light generated by charged particles traversing the modules. In this paper, the design of the front-end electronics to process the signals of those SiPMs and test results from the laboratory and from the Pierre Auger Observatory are described. Compared to our previous prototype, the new electronics shows a higher performance, higher efficiency and lower power consumption, and it has a new acquisition system with increased dynamic range that allows measurements closer to the shower core. The new acquisition system is based on the measurement of the total charge signal that the muonic component of the cosmic ray shower generates in the detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Hands-On Computer Science: The Array of Things Experimental Urban Instrument

Chicago's Array of Things (AoT) project is aptly described as a technology experiment or a "smart city" prototype. The concept of such an extensible "instrument" arose within a larger translational research vision applying computer science and engineering research for the multidimensional benefit of people and communities in cities. The AoT project hypothesized that wireless intelligent sensor networks could enable both quantitative social science and urban monitoring while also stimulating youth interest in science and technology. Successful deployment of such sensor networks could provide open data from urban measurements not only in support of diverse research questions-in environmental dynamics, urban architecture, engineering, and social sciences-but also informing community groups and city planners. Further, the AoT project and its successor SAGE project are a computer science and engineering experiment, but its success is inextricably tied to community engagement and experiential education. Simply put, community acceptance is a prerequisite to installing and testing the instrument.

97 MATHEMATICS AND COMPUTING↗

Development of self-sensing materials for extreme environments based on metamaterial concept and additive manufacturing

Structural health monitoring of an engineered component in a harsh environment is critical for multiple DOE missions including nuclear fuel cycle, subsurface energy production/storage, and energy conversion. Supported by a seeding Laboratory Directed Research & Development (LDRD) project, we have explored a new concept for structural health monitoring by introducing a self-sensing capability into structural components. The concept is based on two recent technological advances: metamaterials and additive manufacturing. A self-sensing capability can be engineered by embedding a metastructure, for example, a sheet of electromagnetic resonators, either metallic or dielectric, into a material component. This embedment can now be realized using 3-D printing. The precise geometry of the embedded metastructure determines how the material interacts with an incident electromagnetic wave. Any change in the structure of the material (e.g., straining, degradation, etc.) would inevitably perturbate the embedded metastructures or metasurface array and therefore alter the electromagnetic response of the material, thus resulting in a frequency shift of a reflection spectrum that can be detected passively and remotely. This new sensing approach eliminates complicated environmental shielding, in-situ power supply, and wire routing that are generally required by the existing active-circuit-based sensors. The work documented in this report has preliminarily demonstrated the feasibility of the proposed concept. The work has established the needed simulation tools and experimental capabilities for future studies.

36 MATERIALS SCIENCE↗

Facilitating Large‐Scale Snow Shedding from In‐Field Solar Arrays using Icephobic Surfaces with Low‐Interfacial Toughness

Abstract Large‐scale accrual of snow and ice on solar arrays in northern latitudes can cause significant power generation losses during winter. Depending on environmental conditions, snow can encompass a wide range in physical characteristics from dry snow (modulus ≈100 kPa and density ≈0.1 g cm −3 ) to bulk ice (modulus ≈8 GPa and density ≈0.9 g cm −3 ). This variation in snow morphology has made the development of a passive, broad‐spectrum, snow and ice‐shedding surface challenging. Here, the authors develop one of the first surfaces that simultaneously possesses both low‐interfacial strength ( τ˄ ice < 50 kPa) and toughness (Γ ice < 0.5 J m −2 ) with ice. These surfaces, fabricated via the addition of mobile polymer chains/oils to a thin polymeric coating, require extremely low detachment forces for ice, enabling its passive shedding at virtually any accretion length scale. Preliminary evidence that the new surfaces can shed different forms of snow and ice from field‐deployed solar arrays, over a range of subzero temperatures for several weeks, leading to significant increases in power generation is provided. The optically transparent surfaces are easily scalable and can be widely deployed by the solar industry in areas that see persistent snow. Other applications include automotive windshields, LIDAR covers for autonomous vehicles, and cold climate optical sensors.

Dhyani, Abhishek↗

Substrate-Wide Confined Shear Alignment of Carbon Nanotubes for Thin Film Transistors

To exploit their charge transport properties in transistors, semiconducting carbon nanotubes must be assembled into aligned arrays comprised of individualized nanotubes at optimal packing densities. However, achieving this control on the wafer-scale is challenging. Here, solution-based shear in substrate-wide, confined channels is investigated to deposit continuous films of well-aligned, individualized, semiconducting nanotubes. Polymer-wrapped nanotubes in organic ink are forced through sub-mm tall channels, generating shear up to 10 000 s -1 uniformly aligning nanotubes across substrates. The ink volume and concentration, channel height, and shear rate dependencies are elucidated. Optimized conditions enable alignment within a ±32° window, at 50 nanotubes µm-1, on 10 × 10 cm 2 substrates. Transistors (channel length of 1–5 µm) are fabricated parallel and perpendicular to the alignment. The parallel transistors perform with 7× faster charge carrier mobility (101 and 49 cm 2 V -1 s -1 assuming array and parallel-plate capacitances, respectively) with high on/off ratio of 105. The spatial uniformity varies ±10% in density, ±2° in alignment, and ±7% in mobility. Deposition occurs within seconds per wafer, and further substrate scaling is viable. Compared to random networks, aligned nanotube films promise to be a superior platform for applications including sensors, flexible/stretchable electronics, and light emitting and harvesting devices.

36 MATERIALS SCIENCE↗

Hard X-ray Fluorescence measurements with TESs at the Advanced Photon Source

Transition Edge Sensor (TES) spectrometers for hard X-ray beamline science will enable improved X-ray emission and absorption spectroscopy in the information-rich 2 to 20keV energy range. We are building a TES-based instrument for time Advanced Photon Source (APS) synchrotron, to be made available to beamline users. 24-pixel prototype arrays have recently been fabricated and tested. the first, spectroscopy measurements using these arrays are promising, with a best single-pixel energy resolution of 11.2 eV and saturation energy > 20 keV. We present a series of recent X-ray Fluorescence measurements involving transition metal elements and multi-element samples with closely spaced emission lines, in particular a Cu-Ni-Co thin film and a foil of Cu and Hf, The TES-measured spectra are directly compared to spectra measured with silicon drift detectors at an APS beamline, demonstrating the improved X-ray science made possible by TES spectrometers.

Guruswamy, Tejas↗

Rotation-Enabled 7-Degree of Freedom Seismometer for Geothermal Resource Development. Phase 1 Final Report

Under this Department of Energy (DOE) grant, A-Tech Corporation d.b.a. Applied Technology Associates (ATA), seeks to develop a seven-degree-of-freedom (7-DOF) seismic measurement tool for high-temperature geothermal applications. The Rotational-Enabled 7-DOF Seismometer includes a conventional tri-axial accelerometer, a conventional pressure sensor or hydrophone, and a tri-axial rotational sensor. The rotational sensing capability is novel, based upon ATA's innovative research in rotational sensing technologies. The geothermal industry requires tools for high-precision seismic monitoring of crack formation associated with Enhanced Geothermal System (EGS) stimulation activity. Currently, microseismic monitoring is conducted by deploying many seismic tools at different depth levels along a 'string' within drilled observation wells. Costs per string can be hundreds of thousands of dollars. Processing data from the spatial arrays of linear seismometers allows back-projection of seismic wave states. In contrast, a Rotational-Enabled 7-DOF Seismometer would simultaneously measure p-wave velocity, s-wave velocity, and incident seismic wave direction all from a single point measurement. In addition, the Rotational-Enabled 7-DOF Seismometer will, by its nature, separate p- and s-waves into different data streams, simplifying signal processing and facilitating analysis of seismic source signatures and geological characterization. By adding measurements of three additional degrees-of-freedom at each level and leveraging the information from this new seismic observable, it is likely that an equally accurate picture of subsurface seismic activity could be garnered with fewer levels per hole. The key cost savings would come from better siting of the well due to increased information content and a decrease in the number of confirmation wells drilled, also due to the increase in information per well. Improved seismic tools may also increase knowledge, understanding, and confidence, thus removing some current blocks to feasibility and significantly increasing access to potential geothermal sites. During the Phase 1 effort summarized in this final report, the ATA Team modeled and built two TRL 3 proof-of-concept test units for two competing rotational sensor technologies. The two competing technologies were based on ATA's angular rate and angular displacement measurement technologies; Angular rate: ATA's Magnetohydrodynamic Angular Rate Sensor (Seismic MHD); and Angular displacement: ATA's Low Frequency Improved Torsional Seismometer (LFITS). In order to down-select between these two technologies and formulate a go / no go decision, the ATA Team analyzed and traded scientific performance requirements and market constraints against sensor characteristics and components, acquiring field data where possible to validate the approach and publishing results from these studies of rotational technology capability. Based on the results of Phase 1, the ATA Team finds that the Seismic MHD (SMHD) technology is the best choice for enabling rotational seismometry and significant technical potential exists for micro-seismic monitoring using a downhole 7-DOF device based on the SMHD. Recent technical papers and field data confirm the potential of rotational sensing for seismic mapping, increasing confidence that cost-reduction benefits are achievable for EGS. However, the market for geothermal rotational sensing is small and undeveloped. As a result, this report recommends modifying the Phase 2 plan to focus on prototype development aimed at partnering with early adopters within the geothermal industry and the scientific research community. The highest public benefit will come from development and deployment of a science-grade SMHD rotational seismometer engineered for geothermal downhole conditions and an integrated test tool for downhole measurements at active geothermal test sites.

15 GEOTHERMAL ENERGY↗

Location deterministic biosensing from quantum-dot-nanowire assemblies

Semiconductor quantum dots (QDs) with high fluorescent brightness, stability, and tunable sizes, have received considerable interest for imaging, sensing, and delivery of biomolecules. In this research, we demonstrate location deterministic biochemical detection from arrays of QD-nanowire hybrid assemblies. QDs with diameters less than 10 nm are manipulated and precisely positioned on the tips of the assembled Gold (Au) nanowires. The manipulation mechanisms are quantitatively understood as the synergetic effects of dielectrophoretic (DEP) and alternating current electroosmosis (ACEO) due to AC electric fields. The QD-nanowire hybrid sensors operate uniquely by concentrating bioanalytes to QDs on the tips of nanowires before detection, offering much enhanced efficiency and sensitivity, in addition to the position-predictable rationality. This research could result in advances in QD-based biomedical detection and inspires an innovative approach for fabricating various QD-based nanodevices.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

The SparkPix-S ASIC for the sparsified readout of 1 MHz frame-rate X-ray cameras at LCLS-II: pixel design and simulation results

Exploiting the “sparse” nature of the information in XPCS (X-ray Photon Correlation Spectroscopy) and XSVS (Speckle Visibility Spectroscopy) experiments, we present the SparkPix-S, a 3-sides buttable Application Specific Integrated Circuit (ASIC) based on a sparsified readout strategy for large-format hybrid detectors. The SparkPix-S architecture, based on the successful ePix family, will be composed as follows: a front-end 2-D matrix of 384×352 square pixels with 50 µm pitch is arranged to match the dimensions of a PIN Si-sensor matrix; charge readout, signal shaping and amplitude discrimination is performed at pixel-level, by means of a low-power (<18 µW) analog processor, which, in case of an event, negotiates access to an analog bus placed every other column; on the chip periphery (balcony), the information on each bus is digitized by an array of successive approximation analog-to-digital converters (SAR-ADCs) running at 10 Msps; on the digital back-end the global logic will generate the output data stream using low-voltage differential signalling (LVDS). A first prototype of the SparkPix-S, with a reduced matrix size of 96×96 pixels, is currently under production on a 130 nm CMOS technology. Simulated performance results show an equivalent noise charge <60 el. r.m.s. at 1 MHz repetition rate, with a maximum input energy of 60 keV and capability to discriminate charge signals with equivalent energy as low as 900 eV.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optics-Free Chip-Scale Intraoperative Imaging Using NIR-Excited Upconverting Nanoparticles

Here we present an optics-free CMOS image sensor that incorporates a novel time-gated dual-photodiode pixel design to allow filter- and lens-less image acquisition of near-infrared-excited (NIR-excited) upconverting nanoparticles. Recent biomedical advances have highlighted the benefits of NIR excitation, but NIR interaction with silicon has remained a challenge, even with high-performance optical blocking filters. Using a secondary diode and a dual-photodiode design, this sensor is able to remove the 100s of mV of NIR background on pixels and bring it down to single-digit mV level, nearing its noise floor of 2.2 mV rms, not achievable with any optical filter. Non-linear effects of background cancellation using the diode pair has been mitigated using an initial one-time pixel-level curve fitting and calibration in a post-processing setting. This imager comprises a highly linear 11 fF metal-oxide-metal (MOM) capacitor and includes integrated angle-selective gratings to reject oblique light and enhance sharpness. Each pixel also includes two distinct correlated double sampling schemes, to remove low frequency flicker noise and systematic offset in the datapath. We demonstrate the performance of this imager using pulsed NIR-excited upconverting nanoparticles on standard United-States-Air-Force (USAF) resolution targets and achieve an SNR of 15 dB, while keeping NIR background below 6 mV. This 36-by-80-pixel array measures only 2.3 mm by 4.8 mm and can be thinned down to 25 µm, allowing it to become surgically compatible with intraoperative instruments and equipment, while remaining optics-free.

42 ENGINEERING↗

The Illumination of Thunderclouds by Lightning: 1. The Extent and Altitude of Optical Lightning Sources

Abstract Optical space‐based lightning sensors including NOAA's Geostationary Lightning Mapper (GLM) detect lightning though its transient illumination of the surrounding clouds. What space‐based optical lightning sensors measure is influenced by the physical attributes of the light source, the location of the source within the cloud scene, and the spatial variations in cloud composition. We focus on the lightning channels that serve as optical sources for GLM groups and flashes in this first part of our thundercloud illumination study. We match Lightning Mapping Array (LMA) sources with GLM groups and flashes during two thunderstorms to examine channel segments that are active during optical emission. We find that in each storm, the LMA sources matched with GLM groups are small (median: 3 km) compared to GLM pixels (nominal: 8 km), and preferentially come from high altitudes in the cloud (>8–10 km). The detection advantage for high‐altitude sources permits GLM to resolve faint optical pulses near the cloud top that might be missed from lower altitudes. However, the most energetic groups can be detected from all altitudes, and the largest groups largely originate at low altitudes. The relationship between group energy and illuminated area depends on flash development within the cloud medium, and flash development into different cloud regions can be identified by tracking GLM metrics of cloud illumination over time.

58 GEOSCIENCES↗

High Energy Micron Scale Pixel Hybrid Detector

The objective of this technology development project has been to fabricate and characterize a new X-ray area image sensor innovation designed for high efficiency detection and imaging of hard X-rays (>20 KeV) with micron scale pixel resolution. A key technology component consists of a monolithic hybrid X-ray detector built by layering an amorphous Selenium X-ray photoconductor film directly deposited on a small pitch (7.8μm) CMOS active pixel readout array. A specific goal of this work is to provide a new detector tool to researchers working with synchrotron light sources, to extend the depth of exploration into nanoscale structures, and do so cost effectively. Early generation X-ray imaging detector tools fail to provide adequate resolving power and efficiency at high energies and our innovation provides a solution. A majority of proposed phase I tasks were completed. Those tasks included, in collaboration with KA Imaging, successful fabrication of specified a-Se layers on a 1Mpixel CMOS readout array to create the direct hybrid X-ray imaging array, packaging of the imaging array, assembly of electronics into a shielded detector box, loading user interface software for camera control and image capture, and performing initial (no X-ray) detector evaluation at Farrier Microengineering facilities. After initial tests, extensive testing using the X-ray beam line 1-BM source at Argonne National Laboratory Advanced Photon Source(ANL-APS) was performed. Imaging performance studies were conducted at multiple X-ray beam energies. Studies included X-ray response vs. X-ray energy, vs. applied detector field strength (HV), response linearity vs. integration time, MTF vs. beam energy, image lag measurements, and micron scale resolution pattern target imaging. This high energy micron scale X-ray detection technology is a first of a kind to be evaluated at the ANL-APS and is supported by Dr. Antonino Miceli, head of the detector physics group. Accomplishments include the first successful demonstration of a 1Mpix amorphous Selenium on CMOS readout direct hybrid X-ray imaging detector at a DOE sponsored National Laboratory. Modeled performance predictions were confirmed, proving micron scale resolution as well as an order of magnitude increase in conversion efficiency over conventional scintillator detector performance. A discovery of evidence of propagation-based phase contrast edge enhancement was unplanned and will be exploited in future experiments. This phase 1 technology demonstration verifies the efficacy of proposed high energy micron scale pixel X-ray hybrid a-Se imaging array products. The new detector products will cost effectively replace early generation detector technologies that currently fail to address increasing demand for tools to study nano structures and physical processes at high X-ray energies above 20keV. For example, current systems for transmission X-ray microscopy have low efficiency and available large pixel (~55µm) direct detectors do not offer sufficient resolution for Bragg fringe imaging at high energies. This detector innovation will solve these inadequacies. The new detector technology will compete in a $50M scientific X-ray detector market, growing at 6%, and will benefit Microtomography(µCT), X-ray diffractometry (XRD), Coherent Diffraction Imaging (CDI) applications. One application specified by Dr. Miceli at ANL is the 3D reconstruction of compact crystals at high energies requires small pixel high efficiency X-ray detectors. Farrier Microengineering, working with colleagues at KA Imaging and the University of Waterloo, successfully achieved the critical objectives of the Phase I proposal. We have proven the technical feasibility of this innovation by building and successfully testing a 1Mpixel a-Se/CMOS hybrid direct X-ray imaging array. Our commercialization roadmap of detector products will be implemented during a phase II project. We will demonstrate a migration of the technology to larger detector array sizes, improved temporal performance with detector layer engineering, and improved environmental and operational stability. Manufacturability and cost effectiveness are key objectives and product designs will leverage current state of the art CMOS wafer fabrication quality and volume manufacturing economics.

36 MATERIALS SCIENCE↗