Search NASA⌕ Search

SEARCH · Search NASA

Results for “software performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 991 records · Page 55

RTN-056: Study of the Photon Transfer Curve in the CCD detectors of the Vera C. Rubin Observatory

The RECA internship program provides Colombian students with an opportunity to enhance their research skills in Astronomy, Astrophysics, and Cosmology. During this three-month program, our main objective was to study the Photon Transfer Curves (PTC) of the Vera C. Rubin Observatory, specifically the gain, and to compare it with the gain obtained through pairs of flats. Overall, the study of PTCs is crucial in understanding the performance of detectors and instruments used in Astronomy. The Vera C. Rubin Observatory is an important facility that will enable researchers to carry out a wide range of studies in this field, making it essential to investigate its gain performance. We used run 13144 to construct the PTCs and 13186 to analyze the crosstalk. We employed the LSST Science Pipelines (also known as the DM stack), a software under development for this observatory, which performs all the necessary reductions for the construction of the PTCs. We also used simulations to replicate the observed effects. Initially, we found a 5% difference between the gain calculated by PTC and pairs of flats for a flow range between 5000 and 10000 ADU. Simulations showed that this difference was due to the handling of statistics and the assumption that the distribution following the Lupton equation is Gaussian. We found an error interval for this flow region based on the vendor, with (1.8 ± 0.7, 4.1 ± 0.9) % for E2V and (0.85 ± 0.7, 2.2 ± 0.9) % for ITL. From the PTC, we also obtained the average Full Well Capacity of LSSTCam as 130000 ± 10000$ electrons. We identified a list of segments where we found differences with the results obtained by SLAC National Acceleration Laboratory in PTC parameters, low saturation level, or other defects. We detected and corrected the effect of statistics in the gain calculation using pairs of flats and proposed a code change, which was implemented in the pipeline software. We do not recommend correcting for crosstalk as it does not significantly affect the parameters and does not change the shape of the PTC. However, the opposite is true for the nonlinearity correction.

79 ASTRONOMY AND ASTROPHYSICS↗

Software Requirements for a Point Kinetics Neutronics Code for Simulating TREAT Reactor Transients

This document provides the software requirements for a computer code to perform point kinetics-based simulations of nuclear reactor transients. These requirements address all aspects of code development and use, including input and output parameters and structure, software capabilities, and supporting documentation. This software is intended to replace the existing point kinetics code TREKIN, which is currently used for the analysis of the Transient Reactor Test Facility (TREAT).

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Architecture and Implementation of OpenPET Firmware and Embedded Software

OpenPET is an open source, modular, extendible, and high-performance platform suitable for multi-channel data acquisition and analysis. Due to the versatility of the hardware, firmware, and software architectures, the platform is capable of interfacing with a wide variety of detector modules not only in medical imaging but also in homeland security applications. Analog signals from radiation detectors share similar characteristics-a pulse whose area is proportional to the deposited energy and whose leading edge is used to extract a timing signal. As a result, a generic design method of the platform is adopted for the hardware, firmware, and software architectures and implementations. The analog front-end is hosted on a module called a Detector Board, where each board can filter, combine, timestamp, and process multiple channels independently. The processed data is formatted and sent through a backplane bus to a module called Support Board, where 1 Support Board can host up to eight Detector Board modules. The data in the Support Board, coming from 8 Detector Board modules, can be aggregated or correlated (if needed) depending on the algorithm implemented or runtime mode selected. It is then sent out to a computer workstation for further processing. The number of channels (detector modules), to be processed, mandates the overall OpenPET System Configuration, which is designed to handle up to 1,024 channels using 16-channel Detector Boards in the Standard System Configuration and 16,384 channels using 32-channel Detector Boards in the Large System Configuration.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-G-IeP3-05: Effects of Image Receptor Technology and Dose Reduction Software On Radiation Dose Estimates for Fluoroscopically-Guided Interventional (FGI) Procedures

Purpose: To investigate the effects of image receptor technology and dose reduction software on radiation dose estimates for most frequently performed fluoroscopically-guided interventional (FGI) procedures at a tertiary health care center. Methods: IRB approval was obtained for retrospective analysis of FGI procedures performed in the interventional radiology suites between January-2011 and December-2015. This included procedures performed using image-intensifier (II) based systems which were subsequently replaced, flat-panel-detector (FPD) based systems which were later upgraded with ClarityIQ dose reduction software (Philips Healthcare) and relatively new FPD system already equipped with ClarityIQ. Post procedure, technologists entered system-reported cumulative air kerma (CAK) and kerma-area product (KAP; only KAP for II based systems) in RIS; these values were analyzed. Data pre-processing included correcting typographical errors and cross-verifying CAK and KAP. The most frequent high and low dose FGI procedures were identified and corresponding CAK and KAP values were compared. Results: Out of 27,251 procedures within this time period, most frequent high and low dose procedures were chemo/immuno-embolization (n=1967) and abscess drainage (n=1821). Mean KAP for embolization and abscess drainage procedures were 260,657, 310,304 and 94,908 mGycm{sup 2}, and 14,497, 15,040 and 6307 mGycm{sup 2} using II-, FPD- and FPD with ClarityIQ- based systems, respectively. Statistically significant differences were observed in KAP values for embolization procedures with respect to different systems but for abscess drainage procedures significant differences were only noted between systems with FPD and FPD with ClarityIQ (p<0.05). Mean CAK reduced significantly from 823 to 308 mGy and from 43 to 21 mGy for embolization and abscess drainage procedures, respectively, in transitioning to FPD systems with ClarityIQ (p<0.05). Conclusion: While transitioning from II- to FPD- based systems was not associated with dose reduction for the most frequently performed FGI procedures, substantial dose reduction was noted with relatively newer systems and dose reduction software.

60 APPLIED LIFE SCIENCES↗

Reproduction of the Yucca Mountain Project TSPA-LA Model Runs using TSPA Computing Systems

Sandia National Laboratories (SNL) conducted an evaluation of total system performance assessment (TSPA) related computing systems for the previously considered Yucca Mountain Project (YMP). This was done to maintain the operational readiness of the computing infrastructure (computer hardware and software) and knowledge capability for total system performance assessment (TSPA) type analysis, as directed by the National Nuclear Security Administration (NNSA), DOE 2010. This work is a continuation of the ongoing readiness evaluation reported in Lee and Hadgu (2014). The current work examined main components of the computing system identified in the previous work (Lee and Hadgu, 2014) to ensure the operational readiness of the TSPA-LA model capability on the server cluster. The TSPA computing hardware and storage system were replaced in late 2014 to maintain core capability and improve computation efficiency. One floating license of GoldSim Version 9.60.300 was installed on the upgraded cluster head node, and its distributed processing capability was mapped on the cluster processors. Other supporting software was tested and installed to support the TSPA-type analysis on the server cluster. All the TSPA-LA modeling cases were tested and verified for the model reproducibility on the upgraded 2014 server cluster (CL2014). All test runs were executed on multiple processors on the server cluster utilizing the GoldSim distributed processing capability, and all runs completed successfully. The model reproducibility verification was evaluated by two approaches: numerical value comparison and graphical comparison. The analysis demonstrated an excellent reproducibility of the TSPA-LA model runs on the upgraded server cluster. The 2014 server cluster and supporting software systems are fully operational to support TSPA- LA type analysis.

97 MATHEMATICS AND COMPUTING↗

Reproduction of the Yucca Mountain Project TSPA-LA Model Runs using TSPA Computing Systems

Sandia National Laboratories (SNL) conducted an evaluation of total system performance assessment (TSPA) related computing systems for the previously considered Yucca Mountain Project (YMP). This was done to maintain the operational readiness of the computing infrastructure (computer hardware and software) and knowledge capability for total system performance assessment (TSPA) type analysis, as directed by the National Nuclear Security Administration (NNSA), DOE 2010. This work is a continuation of the ongoing readiness evaluation reported in Lee and Hadgu (2014). The current work examined main components of the computing system identified in the previous work (Lee and Hadgu, 2014) to ensure the operational readiness of the TSPA-LA model capability on the server cluster. The TSPA computing hardware and storage system were replaced in late 2014 to maintain core capability and improve computation efficiency. One floating license of GoldSim Version 9.60.300 was installed on the upgraded cluster head node, and its distributed processing capability was mapped on the cluster processors. Other supporting software was tested and installed to support the TSPA-type analysis on the server cluster. All the TSPA-LA modeling cases were tested and verified for the model reproducibility on the upgraded 2014 server cluster (CL2014). All test runs were executed on multiple processors on the server cluster utilizing the GoldSim distributed processing capability, and all runs completed successfully. The model reproducibility verification was evaluated by two approaches: numerical value comparison and graphical comparison. The analysis demonstrated an excellent reproducibility of the TSPA-LA model runs on the upgraded server cluster. The 2014 server cluster and supporting software systems are fully operational to support TSPA- LA type analysis.

97 MATHEMATICS AND COMPUTING↗

CRADA FINAL REPORT FOR CRADA NO. CR-08-001 CEMENTITIOUS BARRIERS PARTNERSHIPS

The Cementitious Barriers Partnership (CBP), led by the Savannah River National Laboratory, has achieved its ultimate purpose to support progress in final treatment and disposal of legacy waste and closure of High-Level Waste (HLW) tanks in the DOE complex. The CBP achieved its goal by developing experimental programs with results that supported the development of a reasonable and credible set of software tools to improve understanding and prediction of the structural, hydraulic and chemical performance of cementitious barriers and waste forms used in nuclear applications. These experimental data and software tools are and will continue to reduce the uncertainties in the current methodologies for assessing cementitious barrier performance and increase the consistency and transparency of the assessment process. The CBP has made a significant impact in reducing risk and uncertainties in the performance assessments that directly impact U.S. Department of Energy (DOE) environmental cleanup and closure programs. The CBP has developed an experimentally-based, integrated modeling tool that serves as a screening tool known as the CBP Software Toolbox, Version 3.0. The CBP products reduce the uncertainties of current methodologies for assessing cementitious barrier performance and increasing the consistency and transparency of the DOE assessment process. This CBP Software Toolbox predicts the hydraulic properties and chemical stability of cement matrix phases and release fluxes of constituents, in response to variable boundary conditions. Therefore, the CBP tools are reducing the uncertainty by coupling multiscale and multi-physics processes, including physical-chemical evolution and transport phenomena applied to heterogeneous materials with changing boundary conditions. In addition, the CBP Experimental and Characterization Program has provided test data to support chemical and physical degradation mechanisms for cementitious barriers. These tools have application to low activity waste forms, high level waste tank closure, D&D and entombment of major nuclear facilities, landfill waste acceptance criteria, and in-situ grouting and immobilization of vadose zone contamination. The CBP also provided: 1) a forum for DOE-NRC technical exchange, 2) material characterization to support performance assessment (PA) predictions, 3) uncertainty reduction in PA predictions, 4) base case performance to improve PA predictions, and 5) improvement in understanding and quantification of moisture and contaminant transport used in PAs. Additional CBP accomplishments include: sponsorship of a national test bed workshop to obtain collaboration in establishing the path forward to obtain actual data supporting future predictions of cementitious barrier performance, and participation in an International Atomic Energy Agency (IAEA) Cooperative Research Project on the use of cementitious barriers for low-level radioactive waste treatment and disposal.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

SU-F-T-494: A Multi-Institutional Study of Independent Dose Verification Using Golden Beam Data

Purpose: In general, beam data of individual linac is measured for independent dose verification software program and the verification is performed as a secondary check. In this study, independent dose verification using golden beam data was compared to that using individual linac’s beam data. Methods: Six institutions were participated and three different beam data were prepared. The one was individual measured data (Original Beam Data, OBD) .The others were generated by all measurements from same linac model (Model-GBD) and all linac models (All-GBD). The three different beam data were registered to the independent verification software program for each institute. Subsequently, patient’s plans in eight sites (brain, head and neck, lung, esophagus, breast, abdomen, pelvis and bone) were analyzed using the verification program to compare doses calculated using the three different beam data. Results: 1116 plans were collected from six institutes. Compared to using the OBD, the results shows the variation using the Model-GBD based calculation and the All-GBD was 0.0 ± 0.3% and 0.0 ± 0.6%, respectively. The maximum variations were 1.2% and 2.3%, respectively. The plans with the variation over 1% shows the reference points were located away from the central axis with/without physical wedge. Conclusion: The confidence limit (2SD) using the Model-GBD and the All-GBD was within 0.6% and 1.2%, respectively. Thus, the use of golden beam data may be feasible for independent verification. In addition to it, the verification using golden beam data provide quality assurance of planning from the view of audit. This research is partially supported by Japan Agency for Medical Research and Development(AMED)

60 APPLIED LIFE SCIENCES↗

The development and evaluation of a medical imaging training immersive environment

A novel realistic 3D virtual reality (VR) application has been developed to allow medical imaging students at Queensland University of Technology to practice radiographic techniques independently outside the usual radiography laboratory. A flexible agile development methodology was used to create the software rapidly and effectively. A 3D gaming environment and realistic models were used to engender presence in the software while tutor-determined gold standards enabled students to compare their performance and learn in a problem-based learning pedagogy. Students reported high levels of satisfaction and perceived value and the software enabled up to 40 concurrent users to prepare for clinical practice. Student feedback also indicated that they found 3D to be of limited value in the desktop version compared to the usual 2D approach. A randomised comparison between groups receiving software-based and traditional practice measured performance in a formative role play with real equipment. The results of this work indicated superior performance with the equipment for the VR trained students (P = 0.0366) and confirmed the value of VR for enhancing 3D equipment-based problem-solving skills. Students practising projection techniques virtually performed better at role play assessments than students practising in a traditional radiography laboratory only. The application particularly helped with 3D equipment configuration, suggesting that teaching 3D problem solving is an ideal use of such medical equipment simulators. Ongoing development work aims to establish the role of VR software in preparing students for clinical practice with a range of medical imaging equipment.

07 ISOTOPE AND RADIATION SOURCES↗

HAERO: High-performance aerosols

SAND2021-15059 O Haero is a software library for representing aerosol size distributions, chemical species, and parameterized processes to use with a coupled atmospheric dynamics model or as a standalone tool. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.

Bosler, Peter↗

Benchmarking quantum computers

The rapid pace of development in quantum computing technology has sparked a proliferation of benchmarks to assess the performance of quantum computing hardware and software. However, not all benchmarks are of equal merit. Good ones empower scientists, engineers, programmers and users to understand the power of a computing system, whereas bad ones can misdirect research and inhibit progress. In this Perspective, we survey the science of quantum computer benchmarking. Here, we discuss the role of benchmarks and benchmarking and how good benchmarks can drive and measure progress towards the long-term goal of useful quantum computations, known as quantum utility. We explain how different kinds of benchmark quantify the performance of different parts of a quantum computer, discuss existing benchmarks, examine recent trends in benchmarking, and highlight important open research questions in this field.

Proctor, Timothy James [Sandia National Laboratori↗

WE-AB-204-12: Dosimetry at the Sub-Cellular Scale of Auger-Electron Emitter 99m-Tc in a Mouse Single Thyroid Follicle Model

Purpose: To perform a dosimetry study at the sub-cellular scale of Auger-electron emitter 99m-Tc using a mouse single thyroid cellular model to investigate the contribution of the 99m-Tc Auger-electrons to the absorbed dose and possible link to the thyroid stunning in in vivo experiments in mice, recently reported in literature. Methods: The simulation of S-values for Auger-electron emitting radionuclides was performed using both the recent MCNP6 software and the Geant4-DNA extension of the Geant4 toolkit. The dosimetric calculations were validated through comparison with results from literature, using a simple model of a single cell consisting of two concentric spheres of unit density water and for six Auger-electron emitting radionuclides. Furthermore, the S-values were calculated using a single thyroid follicle model for uniformly distributed 123-I and 125-I radionuclides and compared with published S-values. After validation, the simulation of the S-values was performed for the 99m-Tc radionuclide within the several mouse thyroid follicle cellular compartments, considering the radiative and non-radiative transitions of the 99m-Tc radiation spectrum. Results: The calculated S-values using MCNP6 are in good agreement with the results from literature, validating its use for the 99m-Tc S-values calculations. The most significant absorbed dose corresponds to the case where the radionuclide is uniformly distributed in the follicular cell’s nucleus, with a S-value of 7.8 mGy/disintegration, due mainly to the absorbed Auger-electrons. The results show that, at a sub-cellular scale, the emitted X-rays and gamma particles do not contribute significantly to the absorbed dose. Conclusion: In this work, MCNP6 was validated for dosimetric studies at the sub-cellular scale. It was shown that the contribution of the Auger-electrons to the absorbed dose is important at this scale compared to the emitted photons’ contribution and can’t be neglected. The obtained S-values of Auger-electron emitting 99m-Tc radionuclide will be presented and discussed.

60 APPLIED LIFE SCIENCES↗

Light Water Reactor Sustainability Program: Use of Time Distributions to Predict Operator Procedure Performance in Dynamic Human Reliability Analysis

The Human Unimodel for Nuclear Technology to Enhance Reliability (HUNTER) framework affords software capable of conducting human reliability analysis (HRA) using a dynamic approach built around operating procedures (OPs) from nuclear power plants (NPPs). Previous HUNTER reports document the development of this software tool, the coupling of HUNTER to the simulator code, the collection of operator performance data by using simulators to calibrate HUNTER models, and linking HUNTER to probabilistic risk assessment (PRA) software. The present report largely addresses two topics. The first is a new function in HUNTER called the HUNTER Procedure Performance Predictor (P3). HUNTER P3 uses HUNTER’s built in Monte Carlo tools featuring human performance variability to identify potential error traps in procedures. The second topic is time distribution analysis to generate time inputs for dynamic HRA. The current analysis was performed to investigate time distributions for task primitives, which are the minimum task unit of analysis used in dynamic HRA modeling. Using the time distribution data, the elapsed time for human actions in an extended loss of AC power (ELAP) scenario is then investigated. Time data and prediction are essential for modeling procedure performance.

99 GENERAL AND MISCELLANEOUS↗

Design Optimization of A-Type Heat Exchangers based on High Performance, Non-Round Tubes

Air-to-refrigerant heat exchangers (HXs) have been the topic of considerable research as they are the fundamental heat transfer components of HVAC&R systems. For residential and commercial applications, indoor heat exchangers are often in A-type configurations to reduce air-conditioner system footprint while still delivering the required cooling or heating. Classical HX design practices typically assume a uniform frontal air velocity profile to facilitate the use of conventional tube-fin airside heat transfer and pressure drop correlations for performance prediction. However, it is well-reported throughout the literature that A-type HXs experience significant airflow maldistribution which can severely degrade HX performance. Additionally, recent advancements in simulation software such as Computational Fluid Dynamics (CFD), Finite Element Analysis (FEA) and optimization algorithms have led researchers to consider primary heat transfer surface optimization to achieve highly compact HXs which do not require fins. In this paper, an A-type HX which utilizes shape-optimized non-round tubes is optimized for minimum duct size and airside pressure drop. This is achieved through coupling of an experimentally validated finite volume HX model with automated 2D CFD simulations of airflow through the HX for airside thermal-hydraulic performance evaluation. Preliminary results show that the optimal designs deliver similar capacity while achieving 20% reductions in airside pressure drop and duct cross-section area. Additionally, the optimal design apex angles in this study were similar to those from previous A-Type HX optimization studies for conventional tube-fin HX geometries, suggesting that the apex angle for optimal A-Type configuration performance may be independent of tube geometry.

42 ENGINEERING↗

Sassena — X-ray and neutron scattering calculated from molecular dynamics trajectories using massively parallel computers

Massively parallel computers now permit the molecular dynamics (MD) simulation of multi-million atom systems on time scales up to the microsecond. However, the subsequent analysis of the resulting simulation trajectories has now become a high performance computing problem in itself. Here, we present software for calculating X-ray and neutron scattering intensities from MD simulation data that scales well on massively parallel supercomputers. The calculation and data staging schemes used maximize the degree of parallelism and minimize the IO bandwidth requirements. The strong scaling tested on the Jaguar Petaflop Cray XT5 at Oak Ridge National Laboratory exhibits virtually linear scaling up to 7000 cores for most benchmark systems. Since both MPI and thread parallelism is supported, the software is flexible enough to cover scaling demands for different types of scattering calculations. The result is a high performance tool capable of unifying large-scale supercomputing and a wide variety of neutron/synchrotron technology.

Computer Science↗

PyOECP: A flexible open-source software library for estimating and modeling the complex permittivity based on the open-ended coaxial probe (OECP) technique

Here, we present PyOECP, a Python-based flexible open-source software for estimating and modeling the complex permittivity obtained from the open-ended coaxial probe (OECP) technique. The transformation of the measured reflection coefficient to complex permittivity is performed based on three different methods. The software library contains the dielectric spectra of common reference liquids, which can be used to transform the reflection coefficient into the dielectric spectra. Several Python routines that are commonly employed (e.g., SciPy and NumPy) in the field of science and engineering are required only so that the users can alter the software structure depending on their needs. The modeling algorithm exploits the Markov Chain Monte Carlo method for the data regression. The discrete relaxation models can be built by a proper combination of well-known relaxation models. In addition to these models, electrode polarization, a typical measurement artifact for interpreting dielectric spectra, can be incorporated into the modeling algorithm. A continuous relaxation model, which solves the Fredholm integral equation of the first kind (a mathematically ill-posed problem), is also included. This open-source software enables users to freely adjust the physical parameters to obtain physical insight into their materials under test and will be consistently updated for more accurate measurement and interpretation of dielectric spectra in an automated manner. This work describes the theoretical and mathematical background of the software, lays out the workflow, and validates the software functionality based on both synthetic and empirical data included in the software.

97 MATHEMATICS AND COMPUTING↗

University of Missouri Research Reactor (MURR) Design Demonstration Element End Fitting Structural Rigidity Analysis

The primary objective of this work is to assess the extent to which the stiffness (measured by means of maximum displacement) of the end fittings in the DDE contributes to the stiffness of the entire element, and how it compares to the equivalent stiffness of the end fittings in the LEU element. Structural analysis of both the LEU element and the DDE were performed using COMSOL 5.3a finite element software. Supporting combs are used on the leading and trailing edges of fuel plates for both the LEU element and the DDE. Therefore, simulations with and without combs are performed as two bounding boundary conditions on the leading edge of the fuel plates. Three types of loads are analyzed in this work: the hydraulic load due to the channel flow disparity-induced pressure differential, the thermal load due to the thermal expansion of the fuel plates, and a point load equal in magnitude to the LEU element’s weight.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗