Search NASA⌕ Search

SEARCH · Search NASA

Results for “source configuration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 991 records · Page 55

Critical and Subcritical Californium Source Driven Noise Analysis Experiments with Fresh PWR Fuels Pins

These experiments were performed in 1983 between August 1 and September 16 and used 35 operational days of critical facility time at the Babcock & Wilcox critical facility in Lynchburg, Va. These measurements were to assess the capability of the Cf source driven noise analysis method to measure the subcriticality of light water reactor fresh fuel configurations. This report documents the experiments of 1983 that were not reported at that time. These measurement with 2.459 wt. % 235 U enriched uranium oxide fresh fuel pins started at the delayed critical configuration of the fully assembled pressurized water reactor (PWR) core configuration with 1511 parts per million (ppm) natural boron (19.8 wt. % 10 B) in the water. This was a cylindrical configuration of 4961 fuel pins. After the initial measurements at delayed criticality, subcritical measurements by the Cf source driven noise analysis method were performed in which the number of detectors and Cf source locations were varied. Additional boron was added to the water moderator and reflector to reduce the neutron multiplication factor, with resulting boron concentrations of 1561, 1613, 1765, 1880, 2104, 2384, 2975, 3606, and 4303 ppm. After the completion of these measurements the increased, the boron concentration was returned to that at delayed critical (1511 ppm) and the reactivity was decreased by reducing the number of fuel pins in steps to 3713, 2553, 1281, 749, and 333 fuel pins and then to that (289) of a s ingle square 17 x 17 pin array, corresponding to a single PW fuel element. For all measurement that started at delayed criticality and then reduced the neutron multiplication factor to various subcritical states, inverse kinetics rod drop measurements at the higher reactivities were also performed but not reported here. At all subcritical states the break frequency noise analysis data was fitted to obtain the prompt neutron decay constant. Some data presented in this report are from notes not in the logbook. The purpose of this report is to document the experimental information for the measurements performed so that a later date someone could perform the required uncertainty and calculational analyses and documentation to use these data for an International Nuclear Criticality Safety Benchmark Program (INCSBEP) or Nuclear Energy Agency (NEA) benchmark. The data from these measurements is available from the Laboratory Records Department of Oak Ridge National Laboratory and the logbook is available from INCSBEP at Idaho National Laboratory.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Electronics Upgrades to the Green is Clean Phoswich Detector Systems and Programmatic Implementation at LANL - Phase II Completion - 18403

Los Alamos National Laboratory (LANL) radiological facilities produce low-density room trash that, in many cases, is not contaminated with radioactivity. It has been estimated that 50 to 90% of low-density room trash is free of radioactive contamination and eligible for inclusion in LANL's Green is Clean (GIC) program. The GIC program is a verification program for non-regulated waste from radiation controlled areas that has been actively segregated as nonradioactive through the use of the waste generator's acceptable knowledge. The GIC program has employed two large area Phoswich gamma ray detector systems (HERCULES and ZEUS) to verify that GIC candidate low-density waste contains no radioactivity above background. The large area (127 cm{sup 2}) Phoswich detectors consist of a thin NaI front crystal (3 mm thick) that is optically coupled to a thick CsI back crystal (50 mm thick). The scintillation properties of the two crystals are different enough to allow the system's electronic components to identify the origin of any pulse. The original systems utilize Nuclear Instrumentation Module (NIM) electronics to process the detector signals. The electronics currently in use by the systems are out of date and some components are no longer manufactured. In 2015, phase I upgrades to the GIC detector systems were completed. Phase I objectives included identifying more modern commercially available electronics that could replace the NIM electronics. A pulse shape discriminator (PSD) module, the Digital Gamma Finder (DGF) Pixie-4 made by XIA LLC, that fits in a compact National Instruments{sup TM} PXI chassis was identified to replace the majority of the original NIM bin electronics - a single Pixie-4 module replaces four NIM amplifiers and four NIM pulse shape analyzers (PSAs). Another phase I objective was to show that that new PSD could separate out the NaI and CsI detector signals in a manner equivalent to or better than the NIM electronics. Proof of concept was achieved in 2015 when a prototype upgrade system on ZEUS was built and tested and gating parameter settings were determined that successfully separated the NaI and CsI signals. Phase II required establishing a LabVIEW software interface with Pixie-4 electronics in lieu of the manufacturer provided Pixie-4 software called the Pixie Viewer. In addition, phase II included 1) final optimization of the gating parameters on the prototype Pixie-4 ZEUS system, 2) finalizing Requirements, Design and Test Plan documents, 3) LabVIEW software interface quality assurance (QA) testing, 4) setting up the HERCULES system with the Pixie-4 upgrade electronics, 5) check source and background calibration of both systems, 6) absolute efficiency determination on both systems and 7) procedure revisions and implementation of both systems into routine operations. In 2017 phase II was completed including the preparation of detailed Requirements, Design and Test Plan documents. The LabVIEW interface software that communicates and controls the Pixie-4 has been completed, merged with the preexisting LabVIEW operations software and fully tested. Gating parameter optimization, configuration of HERCULES with the Pixie-4 electronics, check source and background calibrations and absolute efficiency determinations have all been performed - quantitative results are presented in the full paper. For performance validation, comparison measurements of actual GIC bags on both the HERCULES system using the old NIM Bin electronics and the ZEUS system using the upgraded Pixie-4 electronics have been done and evaluated. Finally, procedure revisions and implementation of both systems into routine operations is currently in process and planned to be complete by the end of calendar year 2017. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Acoustic Source Localization in Aircraft Interiors Using Microphone Array Technologies

Using three microphone array configurations at two aircraft body stations on a Boeing 777-300ER flight test, the acoustic radiation characteristics of the sidewall and outboard floor system are investigated by experimental measurement. Analysis of the experimental data is performed using sound intensity calculations for closely spaced microphones, PATCH Inverse Boundary Element Nearfield Acoustic Holography, and Spherical Nearfield Acoustic Holography. Each method is compared assessing strengths and weaknesses, evaluating source identification capability for both broadband and narrowband sources, evaluating sources during transient and steady-state conditions, and quantifying field reconstruction continuity using multiple array positions.

Sklanka, Bernard J.↗

Exchange bias due to coupling between coexisting antiferromagnetic and spin-glass orders

Exchange bias is a property of widespread technological utility, but its underlying mechanism remains elusive, in part because it is rooted in the interaction of coexisting order parameters in the presence of complex magnetic disorder. In this study we show that a giant exchange bias housed within a spin-glass phase arises in a disordered antiferromagnet. The magnitude and robustness of the exchange bias emerges from a convolution of two energetic landscapes, namely the highly degenerate landscape of the spin glass biased by the sublattice spin configuration of the antiferromagnet. The former provides a source of uncompensated moment, whereas the latter provides a mechanism for its pinning, which leads to the exchange bias. Tuning the relative strengths of the spin-glass and antiferromagnetic order parameters reveals a principle for tailoring the exchange bias, with potential applications to spintronic technologies.

36 MATERIALS SCIENCE↗

A new absolute extreme ultraviolet image system designed for studying the radiated power of the Joint Texas Experimental Tokamak discharges

A bolometer imaging system mounted on different toroidal and poloidal locations used for radiation observation has been developed in the Joint Texas Experimental Tokamak (J-TEXT tokamak). Three miniature pinhole AXUV16ELG (16 elements absolute extreme ultraviolet silicon photodiodes) array cameras, which are settled down in the same toroidal position but in three different poloidal places, can provide a broad viewing angle that covers the whole plasma cross-section, and hence can measure the total radiated power and provide the radiated emissive profile, while nine AXUV10EL (10 elements absolute extreme ultraviolet silicon photodiodes) array cameras are divided into three groups and will be mounted on different toroidal locations to observe the toroidal radiated power distribution. Among these detectors, one element of the AXUV16ELG array is absolutely calibrated by the synchrotron radiation source to verify the system reliability. Although there are some discrepancies between the typical responsivity given by IRD Co. and the calibrated results, it is confirmed that the discrepancies have no major effect on the final result after the simulation. The details of the system as well as observations are presented in the paper.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Mass Filtering Function of Magnetic Boundaries in Multi-Cusp Ion Source

In a multi-cusp ion source, magnetic boundaries, together with the difference between plasma potential and plasma chamber potential, functioned as a mass filter which filters out heavier ions in multi-component plasmas. This method was applied to mixed inert gas plasmas and hydrogen plasmas and found to be very effective for general purposes which require to decrease unwanted heavier ions. Using this method to the ion source of iG4, target boron current above 80 mA and proton current above 120 mA were obtained.

43 PARTICLE ACCELERATORS↗

On the covariant gauge {alpha} of the linearized gravity in de Sitter spacetime

In previous work, we studied the linearized gravity with covariant gauge {beta}= 2/3 and {alpha}= 5/3. It was found that the sum of the source and initial contributions reproduces the correct field configuration over the whole de Sitter spacetime. In this paper, we extend this work to generalizing the linearized gravitational field in an arbitrary value of the gauge parameter {alpha} but the gauge parameter {beta} remains the same.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Conduction of molecular electronic devices: Qualitative insights through atom-atom polarizabilities

The atom-atom polarizability and the transmission probability at the Fermi level, as obtained through the source-and-sink-potential method for every possible configuration of contacts simultaneously, are compared for polycyclic aromatic compounds. This comparison leads to the conjecture that a positive atom-atom polarizability is a necessary condition for transmission to take place in alternant hydrocarbons without non-bonding orbitals and that the relative transmission probability for different configurations of the contacts can be predicted by analyzing the corresponding atom-atom polarizability. A theoretical link between the two considered properties is derived, leading to a mathematical explanation for the observed trends for transmission based on the atom-atom polarizability.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Measurement and models of bent KAP(001) crystal integrated reflectivity and resolution (invited)

The Advanced Light Source beamline-9.3.1 x-rays are used to calibrate the rocking curve of bent potassium acid phthalate (KAP) crystals in the 2.3-4.5 keV photon-energy range. Crystals are bent on a cylindrically convex substrate with a radius of curvature ranging from 2 to 9 in. and also including the flat case to observe the effect of bending on the KAP spectrometric properties. As the bending radius increases, the crystal reflectivity converges to the mosaic crystal response. The X-ray Oriented Programs (XOP) multi-lamellar model of bent crystals is used to model the rocking curve of these crystals and the calibration data confirm that a single model is adequate to reproduce simultaneously all measured integrated reflectivities and rocking-curve FWHM for multiple radii of curvature in both 1st and 2nd order of diffraction.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

RADIO JETS AND DISKS IN THE INTERMEDIATE-MASS STAR-FORMING REGION NGC2071IR

We report the results of simultaneous radio continuum and water maser observations toward the NGC 2071IR star-forming region, carried out with the VLA in its A configuration. We detect continuum emission toward the infrared sources IRS 1 and IRS 3 at 1.3 and 3.6 cm. In addition, a new continuum source, VLA 1, is also detected at both wavelengths, which is located between IRS 1 and IRS 3. IRS 1 breaks up into three continuum peaks (IRS 1E, 1C, and 1W), aligned in the east-west direction (P.A. = 100{sup 0}). IRS 1 is the central source, while the sources E and W seem to be condensations ejected by IRS 1. In the same way, IRS 3 is also forming a triple system (IRS 3N, 3C and 3S), which is elongated in the northeast-southwest direction and the condensations, IRS 3N and IRS 3S, are symmetrically located along the major axis. Based on the morphology and the continuum emission, we suggest that both IRS 1 and IRS 3 are radio jets, which have ejected condensations into the interstellar medium. Moreover, IRS 1 and IRS 3 seem to be the driving sources of the large-scale outflows observed in H{sub 2} and CO, respectively. In addition, we also detected water emission toward the systems IRS 1, IRS 3, and the new source VLA 1. Based on the spatial-kinematic distribution of the water masers, we find evidence that the water masers are tracing part of circumstellar disks around IRS 1C and IRS 3C. Moreover, we estimate that the sources IRS 1C and IRS 3C have central masses of approx5 and approx1 M {sub sun}, respectively. We conclude that the radio continuum and water maser emission are tracing disk-YSO-outflow systems toward IRS 1 and IRS 3, which are low- and intermediate-mass young stellar objects, respectively.

79 ASTRONOMY AND ASTROPHYSICS↗

Numerical simulations of optically thick accretion onto a black hole. II. Rotating flow

In this paper, we report on recent upgrades to our general relativistic radiation magnetohydrodynamics code, Cosmos++, including the development of a new primitive inversion scheme and a hybrid implicit-explicit solver with a more general M {sub 1} closure relation for the radiation equations. The new hybrid solver helps stabilize the treatment of the radiation source terms, while the new closure allows for a much broader range of optical depths to be considered. These changes allow us to expand by orders of magnitude the range of temperatures, opacities, and mass accretion rates, and move a step closer toward our goal of performing global simulations of radiation-pressure-dominated black hole accretion disks. In this work, we test and validate the new method against an array of problems. We also demonstrate its ability to handle super-Eddington, quasi-spherical accretion. Even with just a single proof-of-principle simulation, we already see tantalizing hints of the interesting phenomenology associated with the coupling of radiation and gas in super-Eddington accretion flows.

79 ASTRONOMY AND ASTROPHYSICS↗

Design of an epithermal neutron velocity selection system for the Penn State Breazeale Reactor

A series of mechanical neutron choppers to operate as a velocity selection system have been developed for the Pennsylvania State Breazeal Reactor (PSBR). This chopper system will provide pulsed epithermal neutrons in the energy range of 0.5–40 eV with 2% or better energy resolution, and with a transmission of 1E-6 or better. Four different chopper geometries have been evaluated for their utility as mechanical neutron choppers. Specifically, Fermi, ring, piston, and disc choppers have been evaluated to assess their potential neutronics performance and mechanical constructability. A series of high-speed disc choppers were selected for the final design, and optimization work was performed to maximize the neutron pulse intensity. It is estimated that the optimized system will produce an epithermal neutron intensity of approximately 96 n/s. This system can also be operated in a time of flight (TOF) configuration such that the neutrons arriving at the source have a white spectrum. This operation can be accomplished by leaving the second stage of choppers in the open position, or by removing it from the beam completely. Such unique source of epithermal neutrons produced by this chopper system will have applications in both prompt and delayed epithermal neutron activation analysis (ENAA), as well as in neutron resonance transmission analysis (NRTA).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neutrino diffusion and mass ejection in protoneutron stars

We discuss the mass ejection mechanism induced by diffusion of neutrino during the early stage of the protoneutron star cooling. A dynamical calculation is employed in order to determine the amount of matter ejected and the remnant compact object mass. An equation of state considering hadronic and quark phases for the stellar dense matter was used to solve the whole time evolution of the system during the cooling phase. The initial neutrino population was obtained by considering beta equilibrium in the dense stellar matter with confined neutrinos, in the very early period of the deleptonic stage of the nascent pulsar. For specified initial configurations of the protoneutron star, we solve numerically the set of equations of motion together with neutrino diffusion through the dense stellar medium.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Test Results for a Superconducting 28-GHz Ion Source Magnet for FRIB

© 2002-2011 IEEE. The superconducting ECR source magnet for the Facility for Rare Isotope Beams at Michigan State University was designed and built by the Superconducting Magnet Group at Lawrence Berkeley National Laboratory (LBNL). The 28-GHz NbTi ion source magnet features a sextupole-in-solenoids configuration, which is comparable to the VENUS ECR magnet operated at LBNL. A shell-based support structure using bladders and keys has been incorporated into the design to allow for adjustments of the preload and reversibility of the magnet assembly process. The magnet has been assembled and successfully tested to operational currents at LBNL. This paper describes the basic design of the magnet and the passive quench protection system. The test results are also presented, including the quench behavior of the magnet, the training performance, and the magnetic measurement results.

Arbelaez, Diego↗

Mechanical Study of a Superconducting 28-GHz Ion Source Magnet for FRIB

The superconducting electron cyclotron resonance (ECR) source magnet for the facility for rare isotope beams at Michigan State University was designed and built by the Superconducting Magnet Group at Lawrence Berkeley National Laboratory (LBNL) in 2017. The 28 GHz NbTi ion source magnet features a sextupole-in-solenoids configuration which is comparable to the VENUS ECR magnet operated at LBNL. However, the mechanical design of this magnet utilizes a shell-based support structure which allows fine adjustments to the sextupole preload and reversibility of the magnet assembly process. The magnet has been assembled and tested to operational currents at LBNL. This paper describes the mechanical analyses performed to estimate the sextupole's and solenoids' preloads. We will report on the 3-D finite element analysis during room temperature assembly, cool-down, and magnet excitation, and then describe the magnet preload operations. To conclude, we will describe the performance of the support structure during the quench training.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

SU-E-T-304: Study of Secondary Neutrons From Uniform Scanning Proton Beams

Purpose: Secondary neutrons are unwanted byproducts from proton therapy and exposure from secondary radiation during treatment could increase risk of developing a secondary cancer later in a patient's lifetime. The purpose of this study is to investigate secondary neutrons from uniform scanning proton beams under various beam conditions using both measurements and Monte Carlo simulations. Methods: CR-39 Plastic Track Nuclear Detectors (PNTD) were used for the measurement. CR-39 PNTD has tissue like sensitivity to the secondary neutrons but insensitive to the therapeutic protons. In this study, we devised two experimental conditions: a) hollow-phantom; phantom is bored with a hollow cylinder along the direction of the beam so that the primary proton passes through the phantom without interacting with the phantom material, b) cylindrical-phantom; a solid cylinder of diameter close to the beam diameter is placed along the beam path. CR-39 PNTDs were placed laterally inside a 60X20X35 cm3 phantom (hollow-phantom) and in air (cylindrical-phantom) at various angles with respect to the primary beam axis. We studied for three different proton energies (78 MeV, 162 MeV and 226 MeV), using a 4 cm modulation width and 5cm diameter brass aperture for the entire experiment and simulation. A comparison of the experiment was performed using the Monte Carlo code FLUKA. Results: The measured secondary neutron dose equivalent per therapeutic primary proton dose (H/D) ranges from 2.1 ± 0.2 to 25.42 ± 2.3 mSv/Gy for the hollow phantom study, and 2.7 ± 0.3 to 46.4 ± 3.4 mSv/Gy for the cylindrical phantom study. Monte Carlo simulations predicated neutron dose equivalent from measurements within a factor of 5. Conclusion: The study suggests that the production of external neutrons is significantly higher than the production of internal neutrons.

07 ISOTOPE AND RADIATION SOURCES↗

Poster — Thur Eve — 20: CTDI Measurements using a Radiochromic Film-based clinical protocol

The purpose of the study was evaluating accuracy and reproducibility of a radiochromic film-based protocol to measure computer tomography dose index (CTDI) as a part of annual QA on CT scanners and kV-CBCT systems attached to linear accelerators. Energy dependence of Gafchromic XR-QA2 ® film model was tested over imaging beam qualities (50 – 140 kVp). Film pieces were irradiated in air to known values of air-kerma (up to 10 cGy). Calibration curves for each beam quality were created (Film reflectance change Vs. Air-kerma in air). Film responses for same air-kerma values were compared. Film strips were placed into holes of a CTDI phantom and irradiated for several clinical scanning protocols. Film reflectance change was converted into dose to water and used to calculate CTDIvol values. Measured and tabulated CTDIvol values were compared. Average variations of ±5.2% in the mean film reflectance change were observed in the energy range of 80 to 140 keV, and 11.1% between 50 and 140 keV. Measured CTDI values were in average 10% lower than tabulated CTDI values for CT-simulators, and 44% higher for CBCT systems. Results presented a mean variation for the same machine and protocol of 2.6%. Variation of film response is within ±5% resulting in ±15% systematic error in dose estimation if a single calibration curve is used. Relatively large discrepancy between measured and tabulated CTDI values strongly support the trend towards replacing CTDI value with equilibrium dose measurement in the center of cylindrical phantom, as suggested by TG- 111.

07 ISOTOPE AND RADIATION SOURCES↗