Search NASA⌕ Search

SEARCH · Search NASA

Results for “structure imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 991 records · Page 55

An Oculometric Standard to Assess the Performance of the Ocular System for Long Duration Spaceflight

Changes in the human brain, due to spaceflight, have been a challenge to the space program since its inception; a challenge that is becoming more acute as extended International Space Station (ISS) missions become routine, a return to crewed lunar exploration is about to begin, and a multi-year crewed trip to Mars is being planned. Determining the extent to which neurophysiological adaptations may adversely impact performance in operational tasks, assessing the full-time course of these changes, and identifying/mitigating any potential long-term health consequences are crucial steps required to enable safe crew-autonomous, long-duration, deep-space missions. Vision is the predominant perceptual sense used to guide cognition and motor control in humans. Thus, it is critical for the success of any future, long-duration mission to understand how long-term exposure to microgravity and to other stressors of spaceflight and their interactions, impact visual function. This is an especially challenging task given the small and disparate samples from which we have been and will be able to collect human performance data. NASA has recently been carefully tracking spaceflight-induced ophthalmic changes, driven in large part by the fluid shifts related to microgravity. In particular, a recent study of Optical Coherence Tomography (OCT) postflight measures revealed that more than two-thirds of US crew members experience significant increases in retinal thickness after 6month or longer ISS missions. Space Associated Neuro-ocular Syndrome (SANS) also includes visual acuity decrements and other ocular structural changes that could adversely impact in-flight performance as missions become longer. However, the impact of spaceflight on the visual system is not limited to the retina. Recent comparisons of pre-and post-flight brain images have revealed structural changes throughout the brain that implicate visual, visuomotor, and visual-cognitive pathways, consistent with observed functional impacts (e.g., decreased speed/accuracy/timing of fine goal-oriented movements). Current limitations on inflight testing make it very difficult to determine when and under what conditions SANS and other disruptions of human neurological subsystems arise. Currently, one cannot anticipate the time course and extent of impairment and recovery. This study addresses this knowledge gap by creating an integrated framework of the relevant existing literature on visual and oculomotor function during spaceflight with an eye towards complementing current structural measures of visuomotor impairment with new oculometric standard measures. Using eye-movement based visual function assessment and diagnostics would provide a valuable enhancement of crew health and performance monitoring in support of deepspace exploration.

Vision↗

Super resolution for magneto-optical microscopy

Sub-diffraction limited magneto-optical microscopy, such as Kerr or Faraday effect microscopy, provide many advantages to fields of science and technology for measuring, or imaging, the magnetization structures and magnetization domains of materials. Disclosed is a method and system for performing sub-diffraction limited magneto-optic microscopy. The method includes positioning a microlens or microlens layer relative to a surface of a sample to image the surface of the sample, forming a photonic nanojet to probe the surface of the sample, and receiving light reflected by the surface of the sample or transmitted through the sample at an imaging sensor. The methods and associated systems and devices enable sub-diffraction limited imaging of magnetic domains at resolutions 2 to 8 times the classical diffraction limit.

te Velthuis, Suzanne Gabriëlle Everdine↗

AN ERUPTIVE HOT-CHANNEL STRUCTURE OBSERVED AT METRIC WAVELENGTH AS A MOVING TYPE-IV SOLAR RADIO BURST

Hot-channel (HC) structure, observed in the high-temperature passbands of the Atmospheric Imaging Assembly/ Solar Dynamic Observatory , is regarded as one candidate of coronal flux rope that is an essential element of solar eruptions. Here, we present the first radio imaging study of an HC structure in the metric wavelength. The associated radio emission manifests as a moving type-IV (t-IVm) burst. We show that the radio sources co-move outward with the HC, indicating that the t-IV emitting energetic electrons are efficiently trapped within the structure. The t-IV sources at different frequencies present no considerable spatial dispersion during the early stage of the event, while the sources spread gradually along the eruptive HC structure at later stage with significant spatial dispersion. The t-IV bursts are characterized by a relatively high brightness temperature (∼10{sup 7}–10{sup 9} K), a moderate polarization, and a spectral shape that evolves considerably with time. This study demonstrates the possibility of imaging the eruptive HC structure at the metric wavelength and provides strong constraints on the t-IV emission mechanism, which, if understood, can be used to diagnose the essential parameters of the eruptive structure.

79 ASTRONOMY AND ASTROPHYSICS↗

Imaging the environment of a z = 6.3 submillimeter galaxy with SCUBA-2

We describe a search for submillimeter emission in the vicinity of one of the most distant, luminous galaxies known, HerMES FLS3, at z = 6.34, exploiting it as a signpost to a potentially biased region of the early universe, as might be expected in hierarchical structure formation models. Imaging to the confusion limit with the innovative, wide-field submillimeter bolometer camera, SCUBA-2, we are sensitive to colder and/or less luminous galaxies in the surroundings of HFLS3. We use the Millennium Simulation to illustrate that HFLS3 may be expected to have companions if it is as massive as claimed, but find no significant evidence from the surface density of SCUBA-2 galaxies in its vicinity, or their colors, that HFLS3 marks an overdensity of dusty, star-forming galaxies. We cannot rule out the presence of dusty neighbors with confidence, but deeper 450 μm imaging has the potential to more tightly constrain the redshifts of nearby galaxies, at least one of which likely lies at z ≳ 5. If associations with HFLS3 can be ruled out, this could be taken as evidence that HFLS3 is less biased than a simple extrapolation of the Millennium Simulation may imply. This could suggest either that it represents a rare short-lived, but highly luminous, phase in the evolution of an otherwise typical galaxy, or that this system has suffered amplification due to a foreground gravitational lens and so is not as intrinsically luminous as claimed.

79 ASTRONOMY AND ASTROPHYSICS↗

Developing a MATLAB(registered)-Based Tool for Visualization and Transformation

An important step in the structural design and development of spacecraft is the experimental identification of a structure s modal characteristics, such as its natural frequencies and modes of vibration. These characteristics are vital to developing a representative model of any given structure or analyzing the range of input frequencies that can be handled by a particular structure. When setting up such a representative model of a structure, careful measurements using precision equipment (such as accelerometers and instrumented hammers) must be made on many individual points of the structure in question. The coordinate location of each data point is used to construct a wireframe geometric model of the structure. Response measurements obtained from the accelerometers is used to generate the modal shapes of the particular structure. Graphically, this is displayed as a combination of the ways a structure will ideally respond to a specified force input. Two types of models of the tested structure are often used in modal analysis: an analytic model showing expected behavior of the structure, and an experimental model showing measured results due to observed phenomena. To evaluate the results from the experimental model, a comparison of analytic and experimental results must be made between the two models. However, comparisons between these two models become difficult when the two coordinate orientations differ in a manner such that results are displayed in an unclear fashion. Such a problem proposes the need for a tool that not only communicates a graphical image of a structure s wireframe geometry based on various measurement locations (called nodes), but also allows for a type of transformation of the image s coordinate geometry so that a model s coordinate orientation is made to match the orientation of another model. Such a tool should also be designed so that it is able to construct coordinate geometry based on many different listings of node locations and is able to transform the wireframe coordinate orientation to match almost any possible orientation (i.e. it should not be a problem specific application) if it is to be of much value in modal analysis. Also, since universal files are used to store modal parameters and wireframe geometry, the tool must be able to read and extract information from universal files and use these files to exchange model data.The purpose of this project is to develop such a tool as a computer graphical user interface (GUI) capable of performing the following tasks: 1) Browsing for a particular universal file within the computer directory and displaying the name of this file to the screen; 2) Plotting each of the nodes within the universal file in a useful, descriptive, and easily understood figure; 3) Reading the node numbers from the selected file and listing these node numbers to the user for selection in an easily accessible format; 4) Allowing for user selection of a new model orientation defined by three selected nodes; and 5) Allowing the user to specify a directory to which the transformed model s node locations will be saved, and saving the transformed node locations to the specified file.

Anderton, Blake J.↗

Interprofessional Image Verification Workshop for Physician and Physics Residents: A Multi-Institutional Experience

Verification of patient position through pretreatment setup imaging is crucial in modern radiation therapy. As treatment complexity increases and technology evolves, physicist-physician collaboration becomes imperative for safe and successful radiation delivery. Despite the importance of both, residency programs lack formal interprofessional education (IPE) activities or structured training for image verification. Here we show the impact of an interprofessional image verification workshop for residents in a multi-institutional setting.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-C-207B-02: Maximal Noise Reduction Filter with Anatomical Structures Preservation

Purpose: All medical images contain noise, which can result in an undesirable appearance and can reduce the visibility of anatomical details. There are varieties of techniques utilized to reduce noise such as increasing the image acquisition time and using post-processing noise reduction algorithms. However, these techniques are increasing the imaging time and cost or reducing tissue contrast and effective spatial resolution which are useful diagnosis information. The three main focuses in this study are: 1) to develop a novel approach that can adaptively and maximally reduce noise while preserving valuable details of anatomical structures, 2) to evaluate the effectiveness of available noise reduction algorithms in comparison to the proposed algorithm, and 3) to demonstrate that the proposed noise reduction approach can be used clinically. Methods: To achieve a maximal noise reduction without destroying the anatomical details, the proposed approach automatically estimated the local image noise strength levels and detected the anatomical structures, i.e. tissue boundaries. Such information was used to adaptively adjust strength of the noise reduction filter. The proposed algorithm was tested on 34 repeating swine head datasets and 54 patients MRI and CT images. The performance was quantitatively evaluated by image quality metrics and manually validated for clinical usages by two radiation oncologists and one radiologist. Results: Qualitative measurements on repeated swine head images demonstrated that the proposed algorithm efficiently removed noise while preserving the structures and tissues boundaries. In comparisons, the proposed algorithm obtained competitive noise reduction performance and outperformed other filters in preserving anatomical structures. Assessments from the manual validation indicate that the proposed noise reduction algorithm is quite adequate for some clinical usages. Conclusion: According to both clinical evaluation (human expert ranking) and qualitative assessment, the proposed approach has superior noise reduction and anatomical structures preservation capabilities over existing noise removal methods. Senior Author Dr. Deshan Yang received research funding form ViewRay and Varian.

60 APPLIED LIFE SCIENCES↗

System and technique for retrieving depth information about a surface by projecting a composite image of modulated light patterns

A technique, associated system and program code, for retrieving depth information about at least one surface of an object, such as an anatomical feature. Core features include: projecting a composite image comprising a plurality of modulated structured light patterns, at the anatomical feature; capturing an image reflected from the surface; and recovering pattern information from the reflected image, for each of the modulated structured light patterns. Pattern information is preferably recovered for each modulated structured light pattern used to create the composite, by performing a demodulation of the reflected image. Reconstruction of the surface can be accomplished by using depth information from the recovered patterns to produce a depth map/mapping thereof. Each signal waveform used for the modulation of a respective structured light pattern, is distinct from each of the other signal waveforms used for the modulation of other structured light patterns of a composite image; these signal waveforms may be selected from suitable types in any combination of distinct signal waveforms, provided the waveforms used are uncorrelated with respect to each other. The depth map/mapping to be utilized in a host of applications, for example: displaying a 3-D view of the object; virtual reality user-interaction interface with a computerized device; face--or other animal feature or inanimate object--recognition and comparison techniques for security or identification purposes; and 3-D video teleconferencing/telecollaboration.

Hassebrook, Laurence G.↗

Assessment of Laser-Induced Thermal Load on Silicon Nanostructures Based on Ion Desorption Yields

Laser heating of macroscopic objects follows the Fourier law of diffusive heat conduction. However, when the dimensions of a structure approach the mean free path of the phonons, heat transport is properly described by the equations of ballistic-diffusive or ballistic transport. Due to the coexistence of these different mechanisms in most nanostructures, the description of their rapid laser heating becomes complex. Experimental assessment of the thermal load on these structures through IR imaging is currently too slow and lacks the spatial resolution to be useful. In this paper, we introduce a method based on measuring the laser-induced yields of quasimolecular ions that enables the comparison of the thermal loads on different structures. Due to the difference in the activation energies of the desorption processes, sodiated and potassiated peptide ion intensities become equal at a certain surface temperature. The laser fluences at which these ion yields are equal for two different structures correspond to equivalent thermal loads. As an example, we compare the nanosecond laser heating of silicon nanopost arrays (NAPA) with diverse post diameters and periodicities. Assessment of the thermal load through ion yield measurements can also be used to verify model assumptions for heat transport regimes of nanostructures.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Crystal Structure of Marburg Virus VP40 Reveals a Broad, Basic Patch for Matrix Assembly and a Requirement of the N-Terminal Domain for Immunosuppression

Marburg virus (MARV), a member of the filovirus family, causes severe hemorrhagic fever with up to 90% lethality. MARV matrix protein VP40 is essential for assembly and release of newly copied viruses and also suppresses immune signaling in the infected cell. Here we report the crystal structure of MARV VP40. We found that MARV VP40 forms a dimer in solution, mediated by N-terminal domains, and that formation of this dimer is essential for budding of virus-like particles. We also found the N-terminal domain to be necessary and sufficient for immune antagonism. The C-terminal domains of MARV VP40 are dispensable for immunosuppression but are required for virus assembly. The C-terminal domains are only 16% identical to those of Ebola virus, differ in structure from those of Ebola virus, and form a distinct broad and flat cationic surface that likely interacts with the cell membrane during virus assembly. Marburg virus, a cousin of Ebola virus, causes severe hemorrhagic fever, with up to 90% lethality seen in recent outbreaks. Molecular structures and visual images of the proteins of Marburg virus are essential for the development of antiviral drugs. One key protein in the Marburg virus life cycle is VP40, which both assembles the virus and suppresses the immune system. Furthermore, we provide the molecular structure of Marburg virus VP40, illustrate differences from VP40 of Ebola virus, and reveal surfaces by which Marburg VP40 assembles progeny and suppresses immune function.

59 BASIC BIOLOGICAL SCIENCES↗

Visualization of High Latitude Ion Upflow in Support of the Image Mission

The study of the magnetosphere is a 400 year old science that began with the publication by Gilbert, in 1600, of his hypotheses that the Earth was a giant magnet. Since then we have learned many things about the magnetosphere, particularly in the last 40 years of the space age, but we still have many unanswered questions. In spite of the many thousands of observations of this system we still lack a global understanding of how it works. This is due to its large size and tenuous nature that mean that any measurement made of the fields or particles involved only give one a knowledge of the local conditions at a given time. To gain a global perspective through such observations would require the simultaneous operation of thousands of satellites spread throughout the magnetospheric system in addition to observations made on the ground. Such a program would be impractical at least from financial considerations. What is needed for the advancement of magnetospheric physics is to develop the same capabilities that astrophysicists, solar physicists and meteorologists have been using for years --- the ability to stand back from the object under study and see it in its entirety. The challenge for doing this for the magnetosphere is that the particle densities are very low and the material is, for the most part, not luminous. In the last 25 years several ideas have been proposed that would allow at least the imaging of certain portions of the magnetosphere. These include imaging of the plasmasphere through the resonant scattering of solar 304 A from He+ ions, imaging of various hot plasma populations (i.e. the ring current, plasmasheet, upflowing ionospheric ions, etc.) from the neutral atoms that result when ions of these populations charge exchange with the hydrogen geocorona, and imaging the aurora at various wavelengths in the far ultraviolet. In addition, a novel technique for probing various boundaries in the magnetosphere by bouncing low frequency radio waves off of them has been extensively studied. Such a technique is analogous to the way the under water world can be probed with sonar. About five years ago NASA convened a science working group to study the possibility of flying a magnetospheric imaging mission. This resulted in a number of proposals for such a mission, one of which was selected to be the first MIDEX mission, to be launched in early 2000. The mission is called IMAGE (Imager for Magnetopause to Aurora Global Exploration) and its P.I. is J. Burch at SwRI. The IMAGE spacecraft will carry imagers to view the plasmasphere, aurora, ring current, inner plasmasheet, and upflowing ionospheric ions as well as a radio sounder to probe the location, shape and dynamics of the magnetopause, plasmapause, etc. Between its selection last April and the non advocacy mission review, which takes place next spring, the IMAGE teams needs to further refine the design of the mission and its instruments. The theory and modeling (T&M) subgroup of this team has the task of demonstrating what kind of images the instruments on IMAGE will see as well as showing that useful scientific information can be extracted from such images. As a central element to the efforts of the T&M subgroup we have decided to simulate and create synthetic images for the magnetic cloud event of October, 1995. In this event a large cloud, with high plasma densities and strong magnetic fields, ejected from the sun collided with the earth's magnetosphere triggering a three day period of intense magnetic storms and substorms. This event was observed from a number of different spacecraft and on the ground so we have a good data set to work with. In our work we will place the IMAGE spacecraft in the magnetosphere on its proposed orbit, with its proposed instruments, to see what it would see had it been there. Existing models of the plasmasphere, ring current and magnetopause will be run for this event to give the structures for the imaging instruments. There are several models which are lacking and which need to be developed. These include a model for the cusp, the inner plasmasheet and the upflowing ions. My task this summer was to develop the upflowing ion model and use it to create synthetic images.

Wilson, Gordon R.↗

Time-Resolved Molecular Frame Dynamics of Fixed-in-Space CS2 Molecules

Random orientation of molecules within a sample leads to blurred observationsof chemical reactions studied from the laboratory perspective. Methodsdeveloped for the dynamic imaging of molecular structures and processesstruggle with this, as measurements are optimally made in the molecular frame.Here we uselaser alignment to transiently fix CS2 molecules in space longenough to elucidate, in the molecular reference frame, details of ultrafast electronic vibrationaldynamics during a photochemical reaction. These three-dimensional photoelectron imaging results, combined with ongoing efforts in molecular alignment and orientation, presage a wide range of insights obtainable fromtime-resolved studies in the molecular frame.

74 ATOMIC AND MOLECULAR PHYSICS↗

SU-E-T-30: Absorbed Doses Determined by Texture Analysis of Gafchromic EBT3 Films Using Scanning Electron Microscopy: A Feasibility Study

Purpose: The texture analysis method is useful to estimate structural features of images as color, size, and shape. The study aims to determine a dose-response curve by texture analysis of Gafchromic EBT3 film images using scanning electron microscopy (SEM). Methods: The uncoated Gafchromic EBT3 films were prepared to directly scan over the active surface layer of EBT3 film using SEM. The EBT3 films were exposed at a dose range of 0 to 10 Gy using a 6 MV photon beam. The exposed film samples were SEM-scanned at 100X, 1000X, and 3000X magnifications. The four texture features (Homogeneity, Correlation, Contrast, and Energy) were calculated based on the gray level co-occurrence matrix (GLCM) derived from the SEM images at each dose. To validate a correlation between delivered doses and texture features, an R-squared value in linear regression was tested. Results: The results showed that the Correlation index was more suitable as dose indices than the other three texture features due to higher linearity and sensitivity of the dose response curves. Further the Correlation index of 3000X magnified SEM images with 9 pixel offsets had an R-squared value of 0.964. The differences between the delivered doses and the doses measured by this method were 0.9, 1.2, 0.2, and 0.2 Gy at 5, 10, 15, and 20 Gy, respectively. Conclusion: It seems to be feasible to convert micro-scale structural features of {sub χ}t{sub χχχ}he EBT3 films to absorbed doses using the texture analysis method.

60 APPLIED LIFE SCIENCES↗

The need for standardization of nuclear cardiology reporting and data system (NCAD-RADS): Learning from coronary artery disease (CAD), breast imaging (BI), liver imaging (LI), and prostate imaging (PI) RADS

Newer structured reporting manners, the reporting and data system (RADS), have made vast steps in improving standardized and structured reporting, allowing better communication between radiologists and referring providers. This has been implemented in several fields: breast (BI-RADS), lung (Lung-RADS), liver (LI-RADS), thyroid (TI-RADS), prostate (PI-RADS), and in cardiovascular radiology (CAD-RADS). The field of nuclear cardiology began its efforts of standardization years ago; however, a widespread standardized reporting structure has not yet been adopted. Such an approach in nuclear cardiology, the nuclear cardiology reporting and data system (NCAD-RADS), will assist radiologists and treating clinicians in conveying and understanding reports and determining the appropriate next steps in management. By linking explicit findings to defined recommendations, patients will receive more consistent and appropriate care.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Frequency-Domain Streak Camera and Tomography for Ultrafast Imaging of Evolving and Channeled Plasma Accelerator Structures

We demonstrate a prototype Frequency Domain Streak Camera (FDSC) that can capture the picosecond time evolution of the plasma accelerator structure in a single shot. In our prototype Frequency-Domain Streak Camera, a probe pulse propagates obliquely to a sub-picosecond pump pulse that creates an evolving nonlinear index 'bubble' in fused silica glass, supplementing a conventional Frequency Domain Holographic (FDH) probe-reference pair that co-propagates with the 'bubble'. Frequency Domain Tomography (FDT) generalizes Frequency-Domain Streak Camera by probing the 'bubble' from multiple angles and reconstructing its morphology and evolution using algorithms similar to those used in medical CAT scans. Multiplexing methods (Temporal Multiplexing and Angular Multiplexing) improve data storage and processing capability, demonstrating a compact Frequency Domain Tomography system with a single spectrometer.

43 PARTICLE ACCELERATORS↗