LIFE Reactor Study: Fiscal Year 2013 Contract Report
Sensitivity study of LIFE Chamber dynamics with BUCKY radiation hydrodynamics simulation code: We will continue to model the interaction of ICF target ion and x-ray output with the LIFE reactor cavity and first wall using the BUCKY 1-D radiation hydrodynamics code. We specifically will address the approach to a cyclic steady state condition, blast conditions for the final optics, and the first wall temperature. We will interface BUCKY output with LLNL and UIUC codes for long time analysis of chamber conditions. We will perform sensitivity studies of the chamber as directed by LLNL through varying parameters such as the xenon opacities. Task 1 was accomplished. “Hand off” parameters produced by BUCKY were sent to UIUC for use as the source term in VTF 3-D simulations of the LIFE chamber. A number of parameter sweeps were done with the BUCKY code to see the influence on engineering quantities such as first surface maximum temperature and overpressure.