Search NASA⌕ Search

SEARCH · Search NASA

Results for “time resolved”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 991 records · Page 55

Improvement of the intrinsic time resolving power of the Cologne iron-free orange type electron spectrometers

Conversion electron spectroscopy represents an important tool for nuclear structure analysis of medium and heavy nuclei. Two iron-free magnetic electron spectrometers of the orange type have been installed at the Institute for Nuclear Physics of the University of Cologne. The very large transmission of 15% and the very good energy resolution of 1% makes the iron-free orange spectrometer a powerful instrument. By means of fast timing techniques, lifetimes of nuclear excited states can be measured with an accuracy better than 20 ps. For the first time, the energy dependent centroid position of prompt events yielding the time-walk characteristics (the prompt curve) of the orange spectrometer fast timing setup has been measured using prompt secondary {delta}-electrons generated in a pulsed beam experiment. The prompt curve calibrated as a function of energy allows precise lifetime determination down to a few tens of picoseconds by the use of the centroid shift method.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

ArcjetCV: a new machine learning application for extracting time-resolved recession measurements from arc jet test videos

Arc jet Computer Vision (ArcjetCV) is a software application built to automate analysis of arc jet ground test video footage. This includes tracking material recession, sting arm motion, and the shock-material standoff distance. This provides a new capability to resolve and validate new physics associated with non-linear processes. This is an essential step to reduce testing, modeling, and validation uncertainties for heatshield material performance. ArcjetCV uses several types of machine learning (convolutional neural net: CNN, decision tree: DT, k-means unsupervised clustering: KM) to automate the video processing pipeline. These include inferring the start/stop of time segments of interest (1D CNN), measuring the time-dependent 2D recession of the material samples (2D CNN, DT), measuring the time-dependent shock standoff distance (2D CNN, DT), and post-processing cleaning of the recession data (KM). The software also provides a graphical user interface for ease of use. The results of using this tool on arc jet videos show non-linear time-dependent effects can be important for certain materials.

machine learning↗

ArcjetCV: A New Machine Learning Application for Extracting Time-Resolved Recession Measurements From Arc Jet Test Videos

Arc jet Computer Vision (ArcjetCV) is a software application built to automate analysis of arc jet ground test video footage. This includes tracking material recession, sting arm motion, and the shock-material standoff distance. This provides a new capability to resolve and validate new physics associated with non-linear processes. This is an essential step to reduce testing, modeling, and validation uncertainties for heatshield material performance. ArcjetCV uses several types of machine learning (convolutional neural net: CNN, decision tree: DT, k-means unsupervised clustering: KM) to automate the video processing pipeline. These include inferring the start/stop of time segments of interest (1D CNN), measuring the time-dependent 2D recession of the material samples (2D CNN, DT), measuring the time-dependent shock standoff distance (2D CNN, DT), and post-processing cleaning of the recession data (KM). The software also provides a graphical user interface for ease of use. The results of using this tool on arc jet videos show non-linear time-dependent effects can be important for certain materials.

machine learning↗

ArcjetCV: A New Machine Learning Application for Extracting Time-Resolved Recession Measurements From Arc Jet Test Videos

Arc jet Computer Vision (ArcjetCV) is a software application built to automate analysis of arc jet ground test video footage. This includes tracking material recession and the shock-material standoff distance. This provides a new capability to resolve and validate new physics associated with non-linear processes. This is an essential step to reduce testing, modeling, and validation uncertainties for heatshield material performance. ArcjetCV uses several types of machine learning (convolutional neural net: CNN, decision tree: DT, k-means unsupervised clustering: KM) to automate the video processing pipeline. These include inferring the start/stop of time segments of interest (1D CNN), measuring the time-dependent 2D recession of the material samples (2D CNN, DT), measuring the time-dependent shock standoff distance (2D CNN, DT), and post-processing cleaning of the recession data (KM). The software also provides a graphical user interface for ease of use. The results of using this tool on arc jet videos show non-linear time-dependent effects can be important for certain materials and characterizing certain failure modes.

machine learning↗

arcjetCV: A New Machine Learning Application for Extracting Time-Resolved Recession Measurements From Arc Jet Test Videos

Arc jet Computer Vision (ArcjetCV) is a software application built to automate analysis of arc jet ground test video footage. This includes tracking material recession and the shock-material standoff distance. This provides a new capability to resolve and validate new physics associated with non-linear processes. This is an essential step to reduce testing, modeling, and validation uncertainties for heatshield material performance. ArcjetCV uses several types of machine learning (convolutional neural net: CNN, decision tree: DT, k-means unsupervised clustering: KM) to automate the video processing pipeline. These include inferring the start/stop of time segments of interest (1D CNN), measuring the time-dependent 2D recession of the material samples (2D CNN, DT), measuring the time-dependent shock standoff distance (2D CNN, DT), and post-processing cleaning of the recession data (KM). The software also provides a graphical user interface for ease of use. The results of using this tool on arc jet videos show non-linear time-dependent effects can be important for certain materials and characterizing certain failure modes.

machine learning↗

Time-resolved, nonequilibrium carrier dynamics in Si-on-glass thin films for photovoltaic cells

Here, a femtosecond pump–probe spectroscopy method was used to characterize the growth process and transport properties of amorphous silicon-on-glass, thin films, intended as absorbers for photovoltaic cells. We collected normalized transmissivity change (ΔT/T) waveforms and interpreted them using a comprehensive three-rate equation electron trapping and recombination model. Optically excited ~300–500 nm thick Si films exhibited a bi-exponential carrier relaxation with the characteristic times varying from picoseconds to nanoseconds depending on the film growth process. From our comprehensive trapping model, we could determine that for doped and intrinsic films with very low hydrogen dilution the dominant relaxation mode was carrier trapping; while for intrinsic films with large hydrogen content and some texture, it was the standard electron–phonon cooling. In both cases, the initial nonequilibrium relaxation was followed by Shockley–Read–Hall recombination. An excellent fit between the model and the ΔT/T experimental transients was obtained and a correlation between the Si film growth process, its hydrogen content, and the associated trap concentration was demonstrated.

14 SOLAR ENERGY↗

Time-Resolved Neutron Imaging for Hydrogen Uptake in Subsurface Lithologies

Geologic hydrogen production and underground storage are increasingly important for meeting rising energy demands while providing clean-combustion advantages. However, hydrogen’s high diffusivity and propensity for leakage through porous media necessitate direct evaluation of its transport behavior in subsurface materials. Whereas X-ray microcomputed tomography (μCT) studies often employ contrast agents or surrogate gases, this study leverages neutron transmission radiography/CT to observe hydrogen migration in situ. This work represents the first demonstration of real-time neutron radiography of hydrogen migration in reservoir and caprock lithologies. Cylindrical cores of Indiana limestone, Amherst Gray sandstone, and Tumey shale were subjected to constant-pressure hydrogen charging and scanned in real time using high-resolution neutron radiography. Results indicate immediate hydrogen infiltration in sandstone and limestone, with homogeneous distribution detected throughout their pore structure. In contrast, hydrogen remained largely absent from fine-grained shale under the same pressure, except in an apparently localized fracture zone, where neutron signatures confirmed the presence of hydrogen. Subsequent neutron CT of the sandstone sample, using image subtraction against an uncharged reference, corroborated hydrogen distribution patterns. Even under lowpressure, single-phase conditions, distinct neutron imaging signatures of hydrogen were achieved. These preliminary findings underscore the potential of neutron imaging for advancing subsurface hydrogen migration research.

08 HYDROGEN↗

A sessile drop setup for the time-resolved synchrotron study of solid-liquid interactions: Application to intermetallic formation in 55%Al-Zn alloys

We introduce a dedicated setup for measuring by synchrotron diffraction in-situ crystallographic and chemical information at the solid–liquid interface. This setup mostly consists of a double-heating furnace composed of a resistive heating for the solid surface and an inductive heating to produce a liquid droplet. The available high energy and high flux beams allow the rapid reaction kinetics to be investigated with very good time resolution down to 1 ms. An application of this setup is illustrated for the growth mechanisms of intermetallic phases during the hot-dipping of steel in a 55%Al-Zn bath. Results show that the three η-Al{sub 5}Fe{sub 2}, θ-Al{sub 13}Fe{sub 4}, and α-Al{sub 8}Fe{sub 2}Si phases grow at different times and rates during the dipping process, whereas the face-centered cubic AlFe{sub 3} phase is not formed.

36 MATERIALS SCIENCE↗

Time-resolved infrared absorption studies of the dynamics of radical reactions.

There is very little information available about the dynamics of radical+radical interactions. These processes are important in combustion being chain termination steps as well as generating new molecular species. To study these processes, a new experimental apparatus has been constructed to investigate radical-radical dynamics. The first radical or atomic species is produced with a known concentration in a microwave discharge flow system. The second is produced by pulsed laser photolysis of a suitable photolyte. The time dependence of individual rovibrational states of the product is followed by absorption of a continuous infrared laser. This approach will allow the reaction of interest to be differentiated from other radical reactions occurring simultaneously. The experimental approach is highly versatile, being able to detect a number of molecular species of particular interest to combustion processes such as water, methane, acetylene etc. at the state specific level. State specific infrared absorption coefficients of radicals can be measured in situ allowing for the determination of the absolute concentrations and hence branching ratios for reactions having multiple reaction pathways.

03 NATURAL GAS↗

Time-resolved chemical imaging based on stimulated TERS (Final Scientific-Technical Report-Phase-II-DE-SC0013172)

This is the Final Scientific/Technical Report for the DOE FastTrack SBIR Grant from Fiscal Year 2015. The report details the work pursued to scientifically demonstrate ultrahigh spatial resolution in ultrafast spectroscopy and commercially develop a product offering that provides the similar capability to other researchers. Chemical and electronic information associated with molecular-scale processes can be interrogated via optical spectroscopy. By utilizing two ultrafast lasers, one to “pump” and the other to “probe” with time delay between them, researchers are able to study various molecular and electronic dynamics with time resolution in femtosecond range. Due to the diffraction limit associated with these optical techniques, these techniques measure average behavior of ensemble of molecules since individual molecules are typically much smaller than the wavelengths of the lasers being utilized. This report presents the successful demonstration of ultrafast spectroscopy (temporal resolution of 150 femtosecond limited by the laser pulse width) of electronic recovery in carbon nanotubes, revealing different recovery dynamics for individual carbon nanotubes with spatial resolution of ~ 10 nm, more than 50X smaller than the wavelengths used to study them. The report also details the required instrumentation for such measurements and how it plans to offer a turnkey solution to the research community to provide such capability in a user-friendly and low maintenance package.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Unlocking the unfolded structure of ubiquitin: Combining time-resolved x-ray solution scattering and molecular dynamics to generate unfolded ensembles

The unfolding dynamics of ubiquitin were studied using a combination of x-ray solution scattering (XSS) and molecular dynamics (MD) simulations. The kinetic analysis of the XSS ubiquitin signals showed that the protein unfolds through a two-state process, independent of the presence of destabilizing salts. In order to characterize the ensemble of unfolded states in atomic detail, the experimental XSS results were used as a constraint in the MD simulations through the incorporation of x-ray scattering derived potential to drive the folded ubiquitin structure toward sampling unfolded states consistent with the XSS signals. We detail how biased MD simulations provide insight into unfolded states that are otherwise difficult to resolve and underscore how experimental XSS data can be combined with MD to efficiently sample structures away from the native state. Our results indicate that ubiquitin samples unfolded in states with a high degree of loss in secondary structure yet without a collapse to a molten globule or fully solvated extended chain. Finally, we propose how using biased-MD can significantly decrease the computational time and resources required to sample experimentally relevant nonequilibrium states.

Chemistry↗

Diode pumped solid state kilohertz disk laser system for time-resolved combustion diagnostics under microgravity at the drop tower Bremen

We describe a specially designed diode pumped solid state laser system based on the disk laser architecture for combustion diagnostics under microgravity (μg) conditions at the drop tower in Bremen. The two-stage oscillator-amplifier-system provides an excellent beam profile (TEM{sub 00}) at narrowband operation (Δλ < 1 pm) and is tunable from 1018 nm to 1052 nm. The laser repetition rate of up to 4 kHz at pulse durations of 10 ns enables the tracking of processes on a millisecond time scale. Depending on the specific issue it is possible to convert the output radiation up to the fourth harmonic around 257 nm. The very compact laser system is integrated in a slightly modified drop capsule and withstands decelerations of up to 50 g (>11 ms). At first the concept of the two-stage disk laser is briefly explained, followed by a detailed description of the disk laser adaption to the drop tower requirements with special focus on the intended use under μg conditions. In order to demonstrate the capabilities of the capsule laser as a tool for μg combustion diagnostics, we finally present an investigation of the precursor-reactions before the droplet ignition using 2D imaging of the Laser Induced Fluorescence of formaldehyde.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Comparative time-resolved photoemission from the Cu(100) and Cu(111) surfaces

Motivated by the striking dependence of the valence electronic structure of transition metal surfaces on their crystallographic orientation, and by emerging experiments on laser-assisted extended ultraviolet (XUV) photoemission from solid surfaces, we calculate photoemission spectra from Cu(100) and Cu(111) surfaces as a function of the photoelectron final kinetic energy and the delay between the ionizing attosecond XUV pulse train and assisting infrared (IR) laser pulse. Our numerical simulations predict distinct differences in delay-dependent photoelectron energy distributions and photoemission time delays for Cu(100) and Cu(111) surfaces. Furthermore, these differences can be scrutinized experimentally with existing technology in a suggested in situ comparative RABBITT (reconstruction of attosecond beating by interference of two-photon transitions) configuration by placing the two surfaces on a sliding platform while keeping all optical components and pathlengths fixed. Our calculations also show that the inclusion of the Fresnel-reflected incident IR pulse at the metal-vacuum interface modifies photoelectron spectra and photoemission time delays in a characteristic way that reveals the degree of spatial location of the initial electronic states.

74 ATOMIC AND MOLECULAR PHYSICS↗

Time-Resolved Fuel Density Profiles of the Stagnation Phase of Indirect-Drive Inertial Confinement Implosions

The implosion efficiency in inertial confinement fusion depends on the degree of stagnated fuel compression, density uniformity, sphericity, and minimum residual kinetic energy achieved. Compton scattering-mediated 50–200 keV x-ray radiographs of indirect-drive cryogenic implosions at the National Ignition Facility capture the dynamic evolution of the fuel as it goes through peak compression, revealing low-mode 3D nonuniformities and thicker fuel with lower peak density than simulated. By differencing two radiographs taken at different times during the same implosion, we also measure the residual kinetic energy not transferred to the hot spot and quantify its impact on the implosion performance.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗