Search NASA⌕ Search

SEARCH · Search NASA

Results for “timing error evaluation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 991 records · Page 55

Coupling localized Noah-MP-Crop model with the WRF model improved dynamic crop growth simulation across Northeast China

Croplands play a critical role in regulating the energy and moisture exchanges between the land surface and atmosphere. However, the interactions between cropland and climate are usually poorly represented due to a lack of detailed representation in crop types and field management. Here, we coupled the Noah-MP-Crop model with the state-of-the-art Weather Research and Forecasting (WRF) model to explore and evaluate the crop growth dynamics in response to climate variations across Northeast China. The default parameters of the crop model were not exactly suitable for the agricultural ecosystems in Northeast China. The detailed cropland distribution, and crop phenology parameters including growing degree days (GDD) and planting (harvesting) date were first created using multi-source remote sensing products and reanalysis data, and was then successfully used to simulate the growth and yield for corn and soybean and associated energy exchanges. We also optimized and calibrated other crop parameters using the time-series of the Moderate Resolution Imaging Spectroradiometer (MODIS) land surface products. The modified crop model substantially improved the simulation of crop growth, plant physiology, and biomass accumulation for both corn and soybean. Coupling the localized dynamic crop model into the WRF led to considerable decreases in the simulated mean-absolute-errors (MAEs) and biases of the leaf area index, evapotranspiration, and gross primary production compared with the MODIS observed values. Compared with the statistical yield from each province, the modified crop model underestimated the corn yield from 11.1% to 48.6%, whereas overestimated the soybean yield from 16.5% to 162.6%.

54 ENVIRONMENTAL SCIENCES↗

The use of RapidArc volumetric-modulated arc therapy to deliver stereotactic radiosurgery and stereotactic body radiotherapy to intracranial and extracranial targets

Twenty-three targets in 16 patients treated with stereotactic radiosurgery (SRS) or stereotactic body radiotherapy (SBRT) were analyzed in terms of dosimetric homogeneity, target conformity, organ-at-risk (OAR) sparing, monitor unit (MU) usage, and beam-on time per fraction using RapidArc volumetric-modulated arc therapy (VMAT) vs. multifield sliding-window intensity-modulated radiation therapy (IMRT). Patients underwent computed tomography simulation with site-specific immobilization. Magnetic resonance imaging fusion and optical tracking were incorporated as clinically indicated. Treatment planning was performed using Eclipse v8.6 to generate sliding-window IMRT and 1-arc and 2-arc RapidArc plans. Dosimetric parameters used for target analysis were RTOG conformity index (CI{sub RTOG}), homogeneity index (HI{sub RTOG}), inverse Paddick Conformity Index (PCI), D{sub mean} and D5-D95. OAR sparing was analyzed in terms of D{sub max} and D{sub mean}. Treatment delivery was evaluated based on measured beam-on times delivered on a Varian Trilogy linear accelerator and recorded MU values. Dosimetric conformity, homogeneity, and OAR sparing were comparable between IMRT, 1-arc RapidArc and 2-arc RapidArc plans. Mean beam-on times {+-} SD for IMRT and 1-arc and 2-arc treatments were 10.5 {+-} 7.3, 2.6 {+-} 1.6, and 3.0 {+-} 1.1 minutes, respectively. Mean MUs were 3041, 1774, and 1676 for IMRT, 1-, and 2-arc plans, respectively. Although dosimetric conformity, homogeneity, and OAR sparing were similar between these techniques, SRS and SBRT fractions treated with RapidArc were delivered with substantially less beam-on time and fewer MUs than IMRT. The rapid delivery of SRS and SBRT with RapidArc improved workflow on the linac with these otherwise time-consuming treatments and limited the potential for intrafraction organ and patient motion, which can cause significant dosimetric errors. These clinically important advantages make image-guided RapidArc useful in the delivery of SRS and SBRT to intracranial and extracranial targets.

61 RADIATION PROTECTION AND DOSIMETRY↗

MO-G-17A-02: Computer Simulation Studies for On-Board Functional and Molecular Imaging of the Prostate Using a Robotic Multi-Pinhole SPECT System

Purpose: To investigate prostate imaging onboard radiation therapy machines using a novel robotic, 49-pinhole Single Photon Emission Computed Tomography (SPECT) system. Methods: Computer-simulation studies were performed for region-of-interest (ROI) imaging using a 49-pinhole SPECT collimator and for broad cross-section imaging using a parallel-hole SPECT collimator. A male XCAT phantom was computersimulated in supine position with one 12mm-diameter tumor added in the prostate. A treatment couch was added to the phantom. Four-minute detector trajectories for imaging a 7cm-diameter-sphere ROI encompassing the tumor were investigated with different parameters, including pinhole focal length, pinhole diameter and trajectory starting angle. Pseudo-random Poisson noise was included in the simulated projection data, and SPECT images were reconstructed by OSEM with 4 subsets and up to 10 iterations. Images were evaluated by visual inspection, profiles, and Root-Mean- Square-Error (RMSE). Results: The tumor was well visualized above background by the 49-pinhole SPECT system with different pinhole parameters while it was not visible with parallel-hole SPECT imaging. Minimum RMSEs were 0.30 for 49-pinhole imaging and 0.41 for parallelhole imaging. For parallel-hole imaging, the detector trajectory from rightto- left yielded slightly lower RMSEs than that from posterior to anterior. For 49-pinhole imaging, near-minimum RMSEs were maintained over a broader range of OSEM iterations with a 5mm pinhole diameter and 21cm focal length versus a 2mm diameter pinhole and 18cm focal length. The detector with 21cm pinhole focal length had the shortest rotation radius averaged over the trajectory. Conclusion: On-board functional and molecular prostate imaging may be feasible in 4-minute scan times by robotic SPECT. A 49-pinhole SPECT system could improve such imaging as compared to broadcross-section parallel-hole collimated SPECT imaging. Multi-pinhole imaging can be improved by considering pinhole focal length, pinhole diameter, and trajectory starting angle. The project is supported by the NIH grant 5R21-CA156390.

60 APPLIED LIFE SCIENCES↗

Hierarchical Inference of the Lensing Convergence from Photometric Catalogs with Bayesian Graph Neural Networks

Abstract We present a Bayesian graph neural network (BGNN) that can estimate the weak lensing convergence ( κ ) from photometric measurements of galaxies along a given line of sight (LOS). The method is of particular interest in strong gravitational time-delay cosmography (TDC), where characterizing the “external convergence” ( κ ext ) from the lens environment and LOS is necessary for precise Hubble constant ( H 0 ) inference. Starting from a large-scale simulation with a κ resolution of ∼1′, we introduce fluctuations on galaxy–galaxy lensing scales of ∼1″ and extract random sight lines to train our BGNN. We then evaluate the model on test sets with varying degrees of overlap with the training distribution. For each test set of 1000 sight lines, the BGNN infers the individual κ posteriors, which we combine in a hierarchical Bayesian model to yield constraints on the hyperparameters governing the population. For a test field well sampled by the training set, the BGNN recovers the population mean of κ precisely and without bias (within the 2 σ credible interval), resulting in a contribution to the H 0 error budget well under 1%. In the tails of the training set with sparse samples, the BGNN, which can ingest all available information about each sight line, extracts a stronger κ signal compared to a simplified version of the traditional method based on matching galaxy number counts, which is limited by sample variance. Our hierarchical inference pipeline using BGNNs promises to improve the κ ext characterization for precision TDC. The code is available as a public Python package, Node to Joy ⏬ .

79 ASTRONOMY AND ASTROPHYSICS↗

MODELING AND PARAMETRIC STUDY OF END-GAS AUTOIGNITION TO ALLOW THE REALIZATION OF ULTRA-LOW EMISSIONS, HIGH-EFFICIENCY HEAVY-DUTY SPARK-IGNITED NATURAL GAS ENGINES

Engine knock and misfire are barriers to pathways leading to high-efficiency Spark-Ignited (SI) Natural Gas (NG) engines. The general tendency to knock is highly dependent on engine operating conditions and the fuel reactivity. The problem is further complicated by the low emission limits and the wide range of chemical reactivity in pipeline-quality natural gas. Depending on the region and the source of the natural gas, its reactivity, described by its Methane Number (MN), which is analogous to the Octane Number for liquid SI fuels, can span from 65 to 95. In order to realize diesel-like efficiencies, SI NG engines must be designed to operate at high Brake Mean Effective Pressures (BMEP), near or beyond knock limits, over a wide range of fuel reactivity. This requires a deep understanding of the combustion-engine interactions pertaining to flame propagation and End-Gas Autoignition (EGAI), i.e., the autoignition of the unburned gas (end gas) ahead of the flame front. However, EGAI, if controlled, provides an opportunity to increase SI NG engine efficiency by increasing the combustion rate and the total fraction of burned fuel, mitigating the effects of the slow flame speeds characteristic of natural gas fuels, which generally reduce BMEP and increase unburned hydrocarbon emissions. For this reason, to realize diesel-like efficiencies and ultra-low emissions on SI NG engines, this work proposes the study of the main parameters influencing the modeling and prediction of NG EGAI to allow for its control. In this work, a novel EGAI detection and onset determination method was developed to reliably quantify EGAI for data analysis and engine control. The new method allowed the prediction of EGAI on SI NG engines without the need to use engine- and operating-condition-dependent thresholds and reduced the error in quantifying the fraction of the total energy released by the EGAI event by up to 40%pts. One- and three-dimensional engine models were then developed to study the engine/fuel interactions that lead to NG EGAI and its performance benefits. These models, although having decent agreement with experimental data, showed the need to account for NOx chemistry when predicting NG EGAI due to a consistently later prediction of the EGAI onset (~1.65 crank-angle degrees) and thus, a new reduced chemical mechanism for real NG fuels was developed containing NOx chemistry. The new reduced mechanism improved the EGAI onset prediction agreement to within ±0.5 crank-angle degrees and decreased simulation time during combustion by nearly 50% when using the further reduced AREIS50NOx chemical mechanism. These models were then used to study the role of NG composition on EGAI, evaluate the engine/fuel interactions leading to NG EGAI, and perform engine optimization while leveraging EGAI to increase thermal efficiency. Piston design optimization combined with a Controlled EGAI (C-EGAI) combustion mode allowed a Heavy-Duty (HD) SI NG engine to operate at diesel-like efficiencies, i.e., Brake Thermal Efficiency (BTE) ≥44%. Experimental and modeling data analysis revealed that earlier and faster heat release increases combustion efficiency by an average of 1%pts, increases work transferred to the piston resulting in a decrease in exhaust losses by 50% depending on the engine operating condition while slightly increasing heat losses. Finally, the simulation results revealed an opportunity to further enhance the BTE (up to 50%) by enabling C-EGAI combustion at leaner conditions, λ=1.4-1.6.

Bestel, Diego Bernardi↗

THE DEMOGRAPHICS OF BROAD-LINE QUASARS IN THE MASS-LUMINOSITY PLANE. II. BLACK HOLE MASS AND EDDINGTON RATIO FUNCTIONS

We employ a flexible Bayesian technique to estimate the black hole (BH) mass and Eddington ratio functions for Type 1 (i.e., broad line) quasars from a uniformly selected data set of {approx}58, 000 quasars from the Sloan Digital Sky Survey (SDSS) DR7. We find that the SDSS becomes significantly incomplete at M {sub BH} {approx}< 3 Multiplication-Sign 10{sup 8} M {sub Sun} or L/L {sub Edd} {approx}< 0.07, and that the number densities of Type 1 quasars continue to increase down to these limits. Both the mass and Eddington ratio functions show evidence of downsizing, with the most massive and highest Eddington ratio BHs experiencing Type 1 quasar phases first, although the Eddington ratio number densities are flat at z < 2. We estimate the maximum Eddington ratio of Type 1 quasars in the observable universe to be L/L {sub Edd} {approx} 3. Consistent with our results in Shen and Kelly, we do not find statistical evidence for a so-called sub-Eddington boundary in the mass-luminosity plane of broad-line quasars, and demonstrate that such an apparent boundary in the observed distribution can be caused by selection effect and errors in virial BH mass estimates. Based on the typical Eddington ratio in a given mass bin, we estimate growth times for the BHs in Type 1 quasars and find that they are comparable to or longer than the age of the universe, implying an earlier phase of accelerated (i.e., with higher Eddington ratios) and possibly obscured growth. The large masses probed by our sample imply that most of our BHs reside in what are locally early-type galaxies, and we interpret our results within the context of models of self-regulated BH growth.

79 ASTRONOMY AND ASTROPHYSICS↗

Factors Affecting Prostate Volume Estimation in Computed Tomography Images

The aim of this study was to investigate how apex-localizing methods and the computed tomography (CT) slice thickness affected the CT-based prostate volume estimation. Twenty-eight volunteers underwent evaluations of prostate volume by CT, where the contour segmentations were performed by three observers. The bottom of ischial tuberosities (ITs) and the bulb of the penis were used as reference positions to locate the apex, and the distances to the apex were recorded as 1.3 and 2.0 cm, respectively. Interobserver variations to locate ITs and the bulb of the penis were, on average, 0.10 cm (range 0.03-0.38 cm) and 0.30 cm (range 0.00-0.98 cm), respectively. The range of CT slice thickness varied from 0.08-0.48 cm and was adopted to examine the influence of the variation on volume estimation. The volume deviation from the reference case (0.08 cm), which increases in tandem with the slice thickness, was within {+-} 3 cm{sup 3}, regardless of the adopted apex-locating reference positions. In addition, the maximum error of apex identification was 1.5 times of slice thickness. Finally, based on the precise CT films and the methods of apex identification, there were strong positive correlation coefficients for the estimated prostate volume by CT and the transabdominal ultrasonography, as found in the present study (r > 0.87; p < 0.0001), and this was confirmed by Bland-Altman analysis. These results will help to identify factors that affect prostate volume calculation and to contribute to the improved estimation of the prostate volume based on CT images.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Ion-chain sympathetic cooling and gate dynamics

Sympathetic cooling is a technique often employed to mitigate motional heating in trapped-ion quantum computers. However, choosing system parameters such as number of coolants and cooling duty cycle for optimal gate performance requires evaluating trade-offs between motional errors and other slower errors such as qubit dephasing. The optimal parameters depend on cooling power, heating rate, and ion spacing in a particular system. In this study, we aim to analyze best practices for sympathetic cooling of long chains of trapped ions using analytical and computational methods. We use a case study to show that optimal cooling performance is achieved when coolants are placed at the center of the chain and provide a perturbative upper bound on the cooling limit of a mode given a particular set of cooling parameters. In addition, using computational tools, we analyze the trade-off between the number of coolant ions in a chain and the center-of-mass mode heating rate. We also show that cooling as often as possible when running a circuit is optimal when the qubit coherence time is otherwise long. These results provide a roadmap for how to choose sympathetic cooling parameters to maximize circuit performance in trapped-ion quantum computers using long chains of ions.

Cooling & trapping↗

Differential Motion Between Mediastinal Lymph Nodes and Primary Tumor in Radically Irradiated Lung Cancer Patients

Purpose/Objective: In patients with locally advanced lung cancer, planning target volume margins for mediastinal lymph nodes and tumor after a correction protocol based on bony anatomy registration typically range from 1 to 1.5 cm. Detailed information about lymph node motion variability and differential motion with the primary tumor, however, is lacking from large series. In this study, lymph node and tumor position variability were analyzed in detail and correlated to the main carina to evaluate possible margin reduction. Methods and Materials: Small gold fiducial markers (0.35 × 5 mm) were placed in the mediastinal lymph nodes of 51 patients with non-small cell lung cancer during routine diagnostic esophageal or bronchial endoscopic ultrasonography. Four-dimensional (4D) planning computed tomographic (CT) and daily 4D cone beam (CB) CT scans were acquired before and during radical radiation therapy (66 Gy in 24 fractions). Each CBCT was registered in 3-dimensions (bony anatomy) and 4D (tumor, marker, and carina) to the planning CT scan. Subsequently, systematic and random residual misalignments of the time-averaged lymph node and tumor position relative to the bony anatomy and carina were determined. Additionally, tumor and lymph node respiratory amplitude variability was quantified. Finally, required margins were quantified by use of a recipe for dual targets. Results: Relative to the bony anatomy, systematic and random errors ranged from 0.16 to 0.32 cm for the markers and from 0.15 to 0.33 cm for the tumor, but despite similar ranges there was limited correlation (0.17-0.71) owing to differential motion. A large variability in lymph node amplitude between patients was observed, with an average motion of 0.56 cm in the cranial-caudal direction. Margins could be reduced by 10% (left-right), 27% (cranial-caudal), and 10% (anteroposterior) for the lymph nodes and −2%, 15%, and 7% for the tumor if an online carina registration protocol replaced a protocol based on bony anatomy registration. Conclusions: Detailed analysis revealed considerable lymph node position variability, differential motion, and respiratory motion. Planning target volume margins can be reduced up to 27% in lung cancer patients when the carina registration replaces bony anatomy registration.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

THE EVOLUTION OF THE STELLAR MASS FUNCTIONS OF STAR-FORMING AND QUIESCENT GALAXIES TO z = 4 FROM THE COSMOS/UltraVISTA SURVEY

We present measurements of the stellar mass functions (SMFs) of star-forming and quiescent galaxies to z = 4 using a sample of 95,675 K{sub s} -selected galaxies in the COSMOS/UltraVISTA field. The SMFs of the combined population are in good agreement with previous measurements and show that the stellar mass density of the universe was only 50%, 10%, and 1% of its current value at z ∼ 0.75, 2.0, and 3.5, respectively. The quiescent population drives most of the overall growth, with the stellar mass density of these galaxies increasing as ρ{sub star}∝(1 + z){sup –4.7±0.4} since z = 3.5, whereas the mass density of star-forming galaxies increases as ρ{sub star}∝(1 + z){sup –2.3±0.2}. At z > 2.5, star-forming galaxies dominate the total SMF at all stellar masses, although a non-zero population of quiescent galaxies persists to z = 4. Comparisons of the K{sub s} -selected star-forming galaxy SMFs with UV-selected SMFs at 2.5 < z < 4 show reasonable agreement and suggest that UV-selected samples are representative of the majority of the stellar mass density at z > 3.5. We estimate the average mass growth of individual galaxies by selecting galaxies at fixed cumulative number density. The average galaxy with log(M{sub star}/M{sub ☉}) = 11.5 at z = 0.3 has grown in mass by only 0.2 dex (0.3 dex) since z = 2.0 (3.5), whereas those with log(M{sub star}/M{sub ☉}) = 10.5 have grown by >1.0 dex since z = 2. At z < 2, the time derivatives of the mass growth are always larger for lower-mass galaxies, which demonstrates that the mass growth in galaxies since that redshift is mass-dependent and primarily bottom-up. Lastly, we examine potential sources of systematic uncertainties in the SMFs and find that those from photo-z templates, stellar population synthesis modeling, and the definition of quiescent galaxies dominate the total error budget in the SMFs.

79 ASTRONOMY AND ASTROPHYSICS↗

An assessment of atypical mesh topologies for low-Mach large-eddy simulation

An implicit, low-dissipation, low-Mach, variable density control volume finite element formulation is used to explore foundational understanding of numerical accuracy for large-eddy simulation applications on hybrid meshes. Detailed simulation comparisons are made between low-order hexahedral, tetrahedral, pyramid, and wedge/prism topologies against a third-order, unstructured hexahedral topology. Using smooth analytical and manufactured low-Mach solutions, design-order convergence is established for the hexahedral, tetrahedral, pyramid, and wedge element topologies using a new open boundary condition based on energy-stable methodologies previously deployed within a finite-difference context. A wide range of simulations demonstrate that low-order hexahedral- and wedge-based element topologies behave nearly identically in both computed numerical errors and overall simulation timings. Moreover, low-order tetrahedral and pyramid element topologies also display nearly the same numerical characteristics. Although the superiority of the hexahedral-based topology is clearly demonstrated for trivial laminar, principally-aligned flows, e.g., a 1x2x10 channel flow with specified pressure drop, this advantage is reduced for non-aligned, turbulent flows including the Taylor–Green Vortex, turbulent plane channel flow ( Re τ 395), and buoyant flow past a heated cylinder. With the order of accuracy demonstrated for both homogenous and hybrid meshes, it is shown that solution verification for the selected complex flows can be established for all topology types. Although the number of elements in a mesh of like spacing comprised of tetrahedral, wedge, or pyramid elements increases as compared to the hexahedral counterpart, for wall-resolved large-eddy simulation, the increased assembly and residual evaluation computational time for non-hexahedral is offset by more efficient linear solver times. Lastly, most simulation results indicate that modest polynomial promotion provides a significant increase in solution accuracy.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Software-controlled, highly automated intrafraction prostate motion correction with intrafraction stereographic targeting: System description and clinical results

Purpose: A new system for software-controlled, highly automated correction of intrafraction prostate motion,'' intrafraction stereographic targeting'' (iSGT), is described and evaluated. Methods: At our institute, daily prostate positioning is routinely performed at the start of treatment beam using stereographic targeting (SGT). iSGT was implemented by extension of the SGT software to facilitate fast and accurate intrafraction motion corrections with minimal user interaction. iSGT entails megavoltage (MV) image acquisitions with the first segment of selected IMRT beams, automatic registration of implanted markers, followed by remote couch repositioning to correct for intrafraction motion above a predefined threshold, prior to delivery of the remaining segments. For a group of 120 patients, iSGT with corrections for two nearly lateral beams was evaluated in terms of workload and impact on effective intrafraction displacements in the sagittal plane. Results: SDs of systematic ({Sigma}) and random ({sigma}) displacements relative to the planning CT measured directly after initial SGT setup correction were <0.5 and <0.8 mm, respectively. Without iSGT corrections, effective {Sigma} and {sigma} for the 11-min treatments would increase to {Sigma}{sub eff} < 1.1 mm and {sigma}{sub eff} < 1.2 mm. With the iSGT procedure with an action level of 4 mm, effective positioning errors were reduced to {Sigma}{sub eff} < 0.8 mm and {sigma}{sub eff} < 1.0 mm, with 23.1% of all fractions requiring a correction. Computer simulations demonstrated that with an action level of 2 mm, the errors would have been reduced to {Sigma}{sub eff} < 0.6 mm and {sigma}{sub eff} < 0.7 mm, requiring corrections in 82.4% of the fractions. Because iSGT is highly automated, the extra time added by iSGT is <30 s if a correction is required. Conclusions: Without increasing imaging dose, iSGT successfully reduces intrafraction prostate motion with minimal workload and increase in fraction time. An action level of 2 mm is recommended.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A method to improve accuracy and precision of water surface identification for photon depth dose measurements

The objective of this study is to present a method to reduce the setup error inherent in clinical depth dose measurements and, in doing so, to improve entrance dosimetry measurement reliability. Ionization chamber (IC) depth dose measurements are acquired with the depth scan extended into the air above the water surface. An inflection region is obtained in each resulting percent depth ionization (PDI) curve that can be matched against other measurements or to an inflection region obtained from an analogous Monte Carlo (MC) simulation. Measurements are made with various field sizes for the 6 and 18 MV photon beams, with and without a Pb foil in the beam, to determine the sensitivity of the dose inflection region to the beam conditions. The offset between reference and test data set inflection regions is quantified using two separate methods. When comparing sets of measured data, maxima in the second derivative of ionization are compared. When comparing measured data to MC simulation, the offset that minimizes the sum of squared differences between the reference and test curves in the ionization inflection region is found. These methods can be used to quantify the offset between an initial setup (test) position and the true surface (reference) position. The ionization inflection location is found to be insensitive to changes in field size, electron contamination, and beam energy. Data from a single reference condition should be sufficient to identify the surface location. The method of determining IC offsets is general and should be applicable to any IC and other radiation sources. The measurement method could reduce the time and effort required in the initial IC setup at a water surface as setup errors can be corrected offline. Given a reliable set of reference data to compare with, this method could increase the ability of quality assurance (QA) measurements to detect discrepancies in beam output as opposed to discrepancies in IC localization. Application of the measurement method standardizes the procedure for localizing cylindrical ICs at a water surface and thereby improves the reliability of measurements taken with these devices at all depths.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Use of Cone Beam Computed Tomography for Image Guided Gamma Knife Stereotactic Radiosurgery: Initial Clinical Evaluation

Purpose: The present study used cone beam computed tomography (CBCT) to measure the inter- and intrafraction uncertainties for intracranial stereotactic radiosurgery (SRS) using the Leksell Gamma Knife (GK). Methods and Materials: Using a novel CBCT system adapted to the GK radiosurgery treatment unit, CBCT images were acquired immediately before and after treatment for each treatment session within the context of a research ethics board–approved prospective clinical trial. Patients were immobilized in the Leksell coordinate frame (LCF) for both volumetric CBCT imaging and GK-SRS delivery. The relative displacement of the patient's skull to the stereotactic reference (interfraction motion) was measured for each CBCT scan. Differences between the pre- and post-treatment CBCT scans were used to determine the intrafraction motion. Results: We analyzed 20 pre- and 17 post-treatment CBCT scans in 20 LCF patients treated with SRS. The mean translational pretreatment setup error ± standard deviation in the left-right, anteroposterior, and craniocaudal directions was −0.19 ± 0.32, 0.06 ± 0.27, and −0.23 ± 0.2 mm, with a maximum of −0.74, −0.53, and −0.68 mm, respectively. After an average time between the pre- and post-treatment CBCT scans of 82 minutes (range 27-170), the mean intrafraction error ± standard deviation for the LCF was −0.03 ± 0.05, −0.03 ± 0.18, and −0.03 ± 0.12 mm in the left-right, anteroposterior, and craniocaudual direction, respectively. Conclusions: Using CBCT on a prototype image guided GK Perfexion unit, we were able to measure the inter- and intrafraction positional changes for GK-SRS using the invasive frame. In the era of image guided radiation therapy, the use of CBCT image guidance for both frame- and non–frame-based immobilization systems could serve as a useful quality assurance tool. Our preliminary measurements can guide the application of achievable thresholds for inter- and intrafraction discrepancy when moving to a frameless approach.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Clinical implementation of a digital tomosynthesis-based seed reconstruction algorithm for intraoperative postimplant dose evaluation in low dose rate prostate brachytherapy

Purpose: The low dose rate brachytherapy procedure would benefit from an intraoperative postimplant dosimetry verification technique to identify possible suboptimal dose coverage and suggest a potential reimplantation. The main objective of this project is to develop an efficient, operator-free, intraoperative seed detection technique using the imaging modalities available in a low dose rate brachytherapy treatment room. Methods: This intraoperative detection allows a complete dosimetry calculation that can be performed right after an I-125 prostate seed implantation, while the patient is still under anesthesia. To accomplish this, a digital tomosynthesis-based algorithm was developed. This automatic filtered reconstruction of the 3D volume requires seven projections acquired over a total angle of 60 deg. with an isocentric imaging system. Results: A phantom study was performed to validate the technique that was used in a retrospective clinical study involving 23 patients. In the patient study, the automatic tomosynthesis-based reconstruction yielded seed detection rates of 96.7% and 2.6% false positives. The seed localization error obtained with a phantom study is 0.4{+-}0.4 mm. The average time needed for reconstruction is below 1 min. The reconstruction algorithm also provides the seed orientation with an uncertainty of 10 deg. {+-}8 deg. The seed detection algorithm presented here is reliable and was efficiently used in the clinic. Conclusions: When combined with an appropriate coregistration technique to identify the organs in the seed coordinate system, this algorithm will offer new possibilities for a next generation of clinical brachytherapy systems.

61 RADIATION PROTECTION AND DOSIMETRY↗

Efficient evaluation of small failure probability in high-dimensional groundwater contaminant transport modeling via a two-stage Monte Carlo method

In decision-making for groundwater management and contamination remediation, it is important to accurately evaluate the probability of the occurrence of a failure event. For small failure probability analysis, a large number of model evaluations are needed in the Monte Carlo (MC) simulation, which is impractical for CPU-demanding models. One approach to alleviate the computational cost caused by the model evaluations is to construct a computationally inexpensive surrogate model instead. However, using a surrogate approximation can cause an extra error in the failure probability analysis. Furthermore, constructing accurate surrogates is challenging for high-dimensional models, i.e., models containing many uncertain input parameters. To address these issues, we propose an efficient two-stage MC approach for small failure probability analysis in high-dimensional groundwater contaminant transport modeling. In the first stage, a low-dimensional representation of the original high-dimensional model is sought with Karhunen–Loève expansion and sliced inverse regression jointly, which allows for the easy construction of a surrogate with polynomial chaos expansion. Then a surrogate-based MC simulation is implemented. In the second stage, the small number of samples that are close to the failure boundary are re-evaluated with the original model, which corrects the bias introduced by the surrogate approximation. The proposed approach is tested with a numerical case study and is shown to be 100 times faster than the traditional MC approach in achieving the same level of estimation accuracy.

54 ENVIRONMENTAL SCIENCES↗

Comparing two correlated C indices with right‐censored survival outcome: a one‐shot nonparametric approach

The area under the receiver operating characteristic curve is often used as a summary index of the diagnostic ability in evaluating biomarkers when the clinical outcome (truth) is binary. When the clinical outcome is right‐censored survival time, the C index, motivated as an extension of area under the receiver operating characteristic curve, has been proposed by Harrell as a measure of concordance between a predictive biomarker and the right‐censored survival outcome. In this work, we investigate methods for statistical comparison of two diagnostic or predictive systems, of which they could either be two biomarkers or two fixed algorithms, in terms of their C indices. We adopt a U ‐statistics‐based C estimator that is asymptotically normal and develop a nonparametric analytical approach to estimate the variance of the C estimator and the covariance of two C estimators. A z ‐score test is then constructed to compare the two C indices. We validate our one‐shot nonparametric method via simulation studies in terms of the type I error rate and power. We also compare our one‐shot method with resampling methods including the jackknife and the bootstrap. Simulation results show that the proposed one‐shot method provides almost unbiased variance estimations and has satisfactory type I error control and power. Finally, we illustrate the use of the proposed method with an example from the Framingham Heart Study. Copyright © 2014 John Wiley & Sons, Ltd.

Kang, Le↗

Uncertainty-Guided Prediction Horizon of Phase-Resolved Ocean Wave Forecasting Under Data Sparsity: Experimental and Numerical Evaluation

Accurate short-term wave forecasting is critical for the safe and efficient operation of marine structures that rely on real-time, phase-resolved ocean wave information for control and monitoring purposes (e.g., digital twins). These systems often depend on environmental sensors (e.g., waverider buoys, wave-sensing LIDAR). Challenges arise when upstream sensor data are missing, sparse, or phase-shifted due to drift. This study investigates the performance of two machine learning models, time-series dense encoder (TiDE) and long short-term memory (LSTM), for forecasting phase-resolved ocean surface elevations under varying degrees of data degradation. We introduce the τ-trimming algorithm, which adapts the prediction horizon based on uncertainty thresholds derived from historical forecasts. Numerical wave tank (NWT) and wave basin experiments are used to benchmark model performance under short- and long-term data masking, spatially coarse sensor grids, and upstream phase shifts. Results show under a 50% probability of upstream data loss, the τ-trimmed TiDE model achieves a 46% reduction in error at the most upstream target, compared to 22% for LSTM. Furthermore, phase misalignment in upstream data introduces a near-linear increase in forecast error. Under moderate model settings, a ±3 s misalignment increases the mean absolute error by approximately 0.5 m, while the same error is accumulated at ±4 s using the more conservative approach. These findings inform the design of resilient, uncertainty-aware wave forecasting systems suited for realistic offshore sensing environments.

42 ENGINEERING↗