Search NASA⌕ Search

SEARCH · Search NASA

Results for “wind program”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 991 records · Page 55

Hydrogen's Potential Role in Future Energy Systems

Hydrogen is developing as a key energy interface that can benefit the electricity grid, provide energy storage, and be used in a number of key applications that have limited alternatives to today's fossil-energy sources. In 2015, the global hydrogen market was 60 MMT/yr (8 EJ/yr). The Hydrogen Council estimated that it could grow ten-fold to 600 MMT/yr (80 EJ/yr) if industrial, transportation, buildings, and electrical applications grow [1]. Hydrogen is used extensively in oil refining for hydrocracking and hydrodesulfurization. It is also the key intermediate while producing ammonia which is used primarily as a fertilizer. Additional industrial market opportunities include steel production where hydrogen could replace metallurgical coal as a reductant (for example, in the direct iron reduction process) and as a feedstock with carbon dioxide to produce methanol, Fischer-Tropsch liquids, and other organic chemicals. In transportation, hydrogen can be used in applications powered by fuel cells. Currently, material handling equipment is the primary market; however, heavy- and medium-duty trucks and light duty vehicles are other direct options. In addition, a hydrogen carrier such as ammonia is a key transportation opportunity. Because it is a non-carbon form of energy storage, hydrogen can play a key role in heating buildings, either directly or through combined heat and power generation, and in providing seasonal storage for the electricity grid. Research and development (R&D) that reduce costs will likely be necessary for hydrogen to economically participate in steelmaking and organic chemical markets. Likewise, lower-cost fuel cells will likely be needed for hydrogen to compete in many transportation, heat, and power markets. Hydrogen is primarily produced from natural gas or other organic feedstocks (e.g., oil refinery byproducts) today. R&D that can reduce the capital cost of both low-temperature and high-temperature electrolysis is possible. If the capital costs for low temperature electrolysis can be reduced while keeping its ability to respond to varying power input, it could be a flexible load on the grid. As such, it could utilize power that would otherwise be curtailed and thus increase the market opportunity for variable renewable generation such as wind and photovoltaic solar [2]. Because it is at an elevated temperature, high temperature electrolysis has a higher efficiency. In many sites where both heat and electricity are available (e.g., nuclear power plants) it can be the most cost effective option for producing hydrogen and supporting energy generation facilities that are challenged when competing to produce electricity alone. [1] The Hydrogen Council. Hydrogen Scaling Up. November 2017. [2] Ruth M., Jadun P., Elgowainy A. H2@Scale Analysis. U.S. Department of Energy Hydrogen and Fuel Cells Program 2019 Annual Merit Review and Peer Evaluation Meeting. April 30, 2019.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Spatio-temporal changes in CO2 emissions during the second ZERT injection, August-September 2008

This study reports the first field test of a multi-channel, auto-dilution, steady-state, soil-CO2 flux monitoring system being developed to help understand the pathways by which fugitive CO2 from a geologic sequestration site migrates to the surface. The test was conducted from late August through mid-October 2008 at the Zero Emissions Research and Technology (ZERT) project site located in Bozeman, MT. Twenty steady-state and five non-steady-state flux chambers were installed in a 10x15 m area, one boundary of which was directly above a shallow (2-m depth) horizontal injection well located 0.5 m below the water table. A total flux of 52 kg CO2 d-1.was injected into the well for 13 days and the efflux from the soil was monitored by the chambers before, during, and for 33 days after the injection. The results showed a rapid increase in soil efflux once injection started, with maximal values reached within 3-7 d in most chambers. Efflux returned to background levels within a similar time period after injection ceased. A radial efflux pattern was observed to at least 2 m from the injection well, and evidence for movement of the CO2 plume during the injection, presumably due to groundwater flow, was seen. The steady-state chambers yielded very stable data, but 3- to 5-fold higher fluxes than the non-steady-state chambers. The higher fluxes were attributed to vacuum induced in the steady-state chambers by narrow vent tubes. High winds resulted in significant decreases in measured soil CO2 efflux, presumably by enhancing efflux from soil outside the chambers.

continuous monitoring↗

Energy Snapshot - Guyana

This profile provides a snapshot of the energy landscape for Guyana, a country on the northern mainland of South America that is culturally tied to the Caribbean. In the Nationally Determined Contributions, Guyana has committed to develop a mix of wind, solar, biomass and hydro-power to supply both demand of the national grid and the energy requirements for towns and villages in Guyana’s hinterland. Guyana has set an ambitious target of achieving close to 100% renewable energy in the power sector by 2025.

44 EE - Strategic Programs, Energy Transition Init↗

Tri-Level Linear Programming Model for Automatic Load Shedding Using Spectral Clustering

Traditional load shedding schemes can be inadequate in grids with high renewable penetration, leading to unstable events and unnecessary grid islanding. Although for both manual and automatic operating modes load shedding areas have been predefined by grid operators, they have remained fixed, and may be sub-optimal due to dynamic operating conditions. In this work, a distributed tri-level linear programming model for automatic load shedding to avoid system islanding is presented. Preventing islanding is preferred because it reduces the need for additional load shedding besides the disconnection of transmission lines between islands. This is crucial as maintaining the local generation-demand balance is necessary to preserve frequency stability. Furthermore, uneven distribution of generation resources among islands can lead to increased load shedding, causing economic and reliability challenges. This issue is further compounded in modern power systems heavily dependent on non-dispatchable resources like wind and solar. The upper-level model uses complex power flow measurements to determine the system areas to shed load depending on actual operating conditions using a spectral clustering approach. The mid-level model estimates the area system state, while the lower-level model determines the locations and load values to be shed. The solution is practical and promising for real-world applications.

Baquedano-Aguilar, Mario D.↗

High Performance, Low Cost Hydrogen Generation from Renewable Energy

Renewable hydrogen from proton exchange membrane (PEM) electrolysis is gaining strong interest in Europe, especially in Germany where wind penetration is already at critical levels for grid stability. For this application as well as biogas conversion and vehicle fueling, megawatt (MW) scale electrolysis is required. Proton has established a technology roadmap to achieve the necessary cost reductions and manufacturing scale up to maintain U.S. competitiveness in these markets. This project represents a highly successful example of the potential for cost reduction in PEM electrolysis, and provides the initial stack design and manufacturing development for Proton’s MW scale product launch. The majority of the program focused on the bipolar assembly, from electrochemical modeling to subscale stack development through prototyping and manufacturing qualification for a large active area cell platform. Feasibility for an advanced membrane electrode assembly (MEA) with 50% reduction in catalyst loading was also demonstrated. Based on the progress in this program and other parallel efforts, H2A analysis shows the status of PEM electrolysis technology dropping below $3.50/kg production costs, exceeding the 2015 target.

08 HYDROGEN↗

The Monitoring Network of the Vancouver 2010 Olympics

Abstract—An innovative monitoring network was implemented to support the operational and science programs for the Vancouver 2010 Winter Olympics. It consisted of in situ weather stations on custom-designed platforms. The sensors included an HMP45C for temperature, humidity and pressure, a tipping bucket rain gauge, an acoustic snow depth sensor, a Pluvio 1 precipitation gauge and an anemometer placed at gauge height and at 10 m height. Modifications to commercial automated precipitation gauges were necessary for the heavy snowfall conditions. Advanced or emerging technologies were deployed to support scientific and nowcasting studies into precipitation intensity, typing, visibility and wind. The sensors included an FD12P visibility and precipitation sensor, a precipitation occurrence sensing system (POSS) present weather sensor, a Hotplate precipitation sensor and a Parsivel disdrometer. Data were collected at 1 min sampling intervals. A Doppler weather radar was deployed in a valley location and provided critical detailed low-level data. An X-band dual-polarized radar was deployed by the National Oceanic and Atmospheric Administration to monitor Vancouver and Cypress Mountain. Three remote sensing stations for vertical profiling were established. At the base of Whistler Mountain, a micro-rain radar, a 22-channel radiometer, a ceilometer, a Parsivel and a POSS were installed. At the base of Cypress Mountain, a micro-rain radar, a ceilometer, a low cost rain sensor (LCR by ATTEX) and a POSS were installed. At Squamish, a wind profiler and a POSS were installed. Weather sensors were mounted on the Whistler Village Gondola and on the Peak to Peak gondola. Sites were established along the Whistler Mountain slope and at other key locations. The combination of sites and instruments formed a comprehensive network to provide observations appropriate for nowcasting in winter complex terrain and investigate precipitation, visibility and wind processes. The contribution provides a detailed description of the network, their sensors, the innovations and some examples.

Joe, Paul↗

HEMS: Home Energy Management System [SWR-15-12] - Stochastic Optimal Scheduling of Residential Appliances with Renewable Energy Sources

The HEMS algorithm schedules residential appliance operation to minimize the weighted sum of occupant discomfort, total energy cost, peak electricity consumption and carbon footprint, weighted according to occupant preferences. A centralized mixed integer linear programming (MILP) based optimization approach is taken, with the HEMS managing all appliances directly, following a Model Predictive Control (MPC) methodology which determines the optimal schedule over the user-specified scheduling horizon and repeats the optimization at configurable time intervals. The HEMS is developed on the General Algebraic Modeling System (GAMS) using the MILP solver. This system is able to effectively deal with the stochasticity in the distributed system by utilizing Monte Carlo simulation where uncertainties in future electricity price, outdoor temperature, water usage, solar and wind generation can be accounted for. The HEMS controls the operation of the heating, ventilation and air conditioning (HVAC) system, water heater, refrigerator, residential batteries, electric vehicles, standalone micro combined heat and power (CHP) generator, dishwasher, washer/dryer, pool pumps, and lighting.

Pratt, Annabelle↗

Methods for Computing Physically Realistic Estimates of Electric Water Heater Demand Response Resource Suitable for Bulk Power System Planning Models

Demand response is commonly called on to reduce load during system peak times or to respond to contingency events. In future power systems with higher shares of wind and solar generation (which we describe together as variable generation [VG]), demand response could have more opportunities to provide energy shifting or operating reserve services. This report evaluates the ability of residential electric water heaters, both electric resistance water heaters (ERWHs) and heat pump water heaters (HPWHs), to provide such services starting from detailed whole-building energy models that realistically represent New England single family home stock. We use a parsimonious surrogate model to represent operational flexibility in a form suitable for linear and mixed integer programming. This enables relatively fast determination of aggregate contingency reserve resource, price-taking energy shifting outcomes, and in some cases the determination of aggregate models at the megawatt (MW) scale that can be directly included in large-scale grid models. After selecting modeling methods and parameters through various computational experiments, we find interquartile ranges of contingency reserve resource in ISO-NE for about 603,400 ERWHs of 45 MW - 69 MW for Claim10 (50 minute responses provided with 10 minutes of advanced notification) and 65 MW - 102 MW for Claim30 (30 minute responses provided with 30 minutes of advanced notification), and for about 619,000 HPWHs of 48 MW - 88 MW for Claim10 and 52 MW - 90 MW for Claim30. The overall reserve resource is up to 32% of total load for ERWHs providing Claim10 service, 47% for ERWHs providing Claim30 service, 93% for HPWHs providing Claim10 service, and 97% for HPWHs providing Claim30 service. More work is required to determine if HPWHs are inherently more suitable than ERWHs for providing contingency reserve or if these results reflect idiosyncrasies of the single family home stock model used in this study. The value of this contingency resource in a Near-term VG model of ISO-NE is $\$ 0.40$ to $\$1.20$ per water heater-year, and significantly larger, $\$ 3.80$ to $\$ 5.30$ per water heater-year in a Mid-term VG model of ISONE. Aggregating surrogate models to the MW-scale for energy shifting service is more challenging than for contingency service and we only present such results for ERWHs, because we were unable to determine satisfactory ways to deal with HPWHs' time-varying and path dependent operational characteristics. Individual surrogate models suitable for evaluating the energy shifting resource from both ERWHs and HPWHs are created, however, and dispatched against day-ahead prices from the Near-Term VG and Mid-Term VG models of ISO-NE. The individual surrogate models are able to access and potentially shift all 640 GWh of HPWH load and 1,547 GWh of ERWH load we modeled in two different single family home stock models. In contrast, the most effective model of aggregate ERWH shifting resource we created only captured 34.7% of the total ERWH load. Energy shifting affected by price-taking dispatch against modeled day-ahead energy prices produces per water heater year profits of $\$19.44$ - $\$22.93$ for individual HPWHs, $\$39.11$ - $\$40.54$ for individual ERWHs, and up to $\$4.00$ - $\$4.24$ for aggregated ERWHs, with the variations mainly due to grid conditions (more or less VG). When the supply-side response to these changes is accounted for, the per water heater year production cost savings for ISO-NE are $\$7.50$ to $\$17.70$ for the most effective set of endogenously dispatched aggregate ERWHs, $\$15.60$ to $\$15.70$ for individual ERWHs dispatched against the DA prices, and $\$10.70$ to $\$11.20$ for individual HPWHs dispatched against DA prices. Those ranges primarily represent the difference between Near-Term VG and Mid-Term VG grid conditions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The BTSbot-nearby Discovery of SN 2024jlf: Rapid, Autonomous Follow-up Probes Interaction in an 18.5 Mpc Type IIP Supernova

We present observations of the Type IIP supernova (SN) SN 2024jlf, including spectroscopy beginning just 0.7 days (∼17 hr) after first light. Rapid follow-up was enabled by the new BTSbot-nearby program, which involves autonomously triggering target-of-opportunity requests for new transients in Zwicky Transient Facility data that are coincident with nearby (D < 60 Mpc) galaxies and identified by the BTSbot machine learning model. Early photometry and nondetections shortly prior to first light show that SN 2024jlf initially brightened by >4 mag day −1 , quicker than ∼90% of Type II SNe. Early spectra reveal weak flash ionization features: narrow, short-lived (1.3 < τ[days] < 1.8) emission lines of Hα, He II , and C IV . Assuming a wind velocity of v w = 50 km s −1 , these properties indicate that the red supergiant progenitor exhibited enhanced mass loss in the last year before explosion. We constrain the mass-loss rate to $1{0}^{-4}\lt \dot{M}\,[{M}_{\odot }\,{\mathrm{yr}}^{-1}]\lt 1{0}^{-3}$ by matching observations to model grids from two independent radiative hydrodynamics codes. BTSbot-nearby automation minimizes spectroscopic follow-up latency, enabling the observation of ephemeral early-time phenomena exhibited by transients.

core-collapse supernovae↗

THE USA’S ADVANCED REACTOR TECHNOLOGIES (ART) GRAPHITE R&D PROGRAM

The USA DOE Advanced Reactor Technologies (ART) graphite R&D program supporting HTR design is one of the longest running nuclear graphite R&D programs. Significant progress has been made in several areas of research within this extensive program including unirraidated and irradiated testing of nuclear graphite, oxidation results and modeling, fracture behavior, irradiation damage studies, and several international collaboration studies. The latest results in these research areas as well as a discussion of a new direction in nuclear graphite irradiation for the USA program will be presented. Recently, the USA made a decision to support moderate to high dose irradiation of nuclear graphite (0.5 to 15 dpa). This will provide irradiation data for graphite HTR core components up to 15 dpa for numerous nuclear graphite grades. The irradiation plan and a tentative schedule for this new irradiation direction will be presented in detail.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Detecting gas leaks using unmanned aerial vehicles

Methods, systems and computer program products for detecting gas leaks using a drone are provided. Aspects include capturing a first set of data regarding a presence of a gas in the geographic area while flying along the initial flight path. Aspects also include creating secondary flight paths through regions in the geographic area in which the presence of the gas exceeds a threshold amount and capturing a second set of data regarding a concentration of the gas in the one or more regions while flying along the secondary flight paths. Aspects further include capturing wind data while flying along the initial and second flight paths and creating a three-dimensional gas plume model for gas leaks identified in the geographic area based on the first set of data, the second set of data and the wind data, wherein the three-dimensional gas plume model identifies a source of the gas leaks.

47 OTHER INSTRUMENTATION↗

K-25 Structural Separation and Demolition

The K-25 building is a former gaseous diffusion plant, built in 1944-1945 as part of the United States Manhattan Project. The structure was the largest structure under one roof, surpassed only by the Pentagon. Together the three wings represent about 17.8 hectare (44 acres) under roof and are generally about 18.3 meters (60 ft.) high on the outside face and approximately 12.2 meters (40 ft.) high on the inside face. The entire structure was built in the shape of a 'U', with a lateral distance of approximately one mile. It was constructed in individual building units with each unit connected using expansion joint-type connection. A single unit is approximately 24.4 meters (80 ft.) across and 122 meters (400 ft.) deep. The northern structure is connected to the eastern and western structures at the upper level floors. The four-level, U-shaped building is a steel-frame structure with corrugated cement-asbestos siding. The cell level is an elevated concrete structure supported by reinforced concrete columns located in the basement, or vault area. The vault area can be accessed at grade level from the outside perimeter. Inside the courtyard, the grade level has been raised to provide entry to the second or cell floor level. An engineering evaluation of the structure was performed to determine the condition of the structure and possibility of unplanned collapse of any portion of the structure. The evaluation included physical inspections, calculations for wind, pre-demolition loads, and evaluation of failure modes. The results of the evaluation have provided guidance for the demolition plan and the development of criteria for protection of personnel performing pre-demolition activities. Challenges include degradation of the structure that necessitated repair, dealing with changes in the code revisions from both the American Concrete Institute (ACI) and the American Institute of Steel Construction (AISC), access to areas of the structure that were not necessarily designed for access, and acceleration of the building degradation due to the pre-demolition activities. When a full building is evaluated, 50 percent of wind and applied forces are dissipated in 3 units and 80 percent is dissipated in 12 units. The forces are basically linear for the first 6 units once the building is opened at the start of demolition. Some column buckling, based on current codes, was noted in the analysis that would have to be mitigated to ensure a controlled demolition. Loading for the removal of the equipment required structural engineering evaluation of the certainty of the load and the application of the load. Corbels are being evaluated through an inspection program and criteria for repair based on current loading and anticipated additional live loads. Access issues continue to be a challenge and have created the need for a significant fall protection program. Other areas of access require different approaches and engineering solutions, sometime considering ultimate strength design versus standard yield stress design. An evaluation of separating a wing into two sections to allow for worker re-entry to perform pre-demolition activities during the demolition off shift was conducted. The evaluation has shown that because of both design and history of the K-25 and K-27 Buildings, significant care and attention is needed to demolish these structures from a structural perspective. When the project schedule issues are overlaid, that may demand workers in other parts of the structure after demolition has begun, the structural issues become severe, demanding exacting analysis and significant controls to ensure the safety of the workers both in and outside the building performing the demolition work.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Batteries Included: Top 10 Findings from Berkeley Lab Research on the Growth of Hybrid Power Plants in the United States

One of the most important electric power system trends of the 2010s was the rapid deployment of wind turbines and photovoltaic arrays, but a twist for the 2020s may be the rapid deployment of ‘hybrid’ generation resources. Hybrid power plants typically combine solar or wind (or other energy sources) with co-located storage. While hybridization helps to ease the challenge of balancing variable supply and demand, its relative novelty means that research is needed to facilitate integration and promote innovation. Combining the characteristics of multiple energy, storage, and conversion technologies poses complex questions for grid operations and economics. Project developers, system operators, planners, and regulators would benefit from better data, methods, and tools to estimate the costs, values, and system impacts of hybrid projects. This publication showcases some of Berkeley Lab’s robust research program intended to support private- and public-sector decision-making about hybrid plants in the United States. Our short briefing summarizes articles that we published between 2020 and 2022, links to the in-depth reports, and provides contact details for further engagement on the specific research topics: Growth: Developer interest in hybrid power plants is strong and growing Price vs. Value: PV+storage hybrids have low PPA prices and high value in some regions Market Drivers: Solar hybridization is driven by tax credits and other benefits Configuration Choices: Market prices have incentivized shorter duration batteries with PV Capacity Value: The capacity contribution of a hybrid is less than the sum of its parts Ancillary Services: AS markets are a valuable yet fleeting option for hybrids Market Participation: Hybrids can more flexibly engage with electricity markets Operations: The power system value of hybrids depends on how they are operated Distributed Hybrids: Growth of customer-sited PV+storage hybrids offers new opportunities Future Research: Where next? Priority areas for hybrid power research.

25 ENERGY STORAGE↗

Topographic Effects on Radiation in the WRF Model with the Immersed Boundary Method: Implementation, Validation, and Application to Complex Terrain

Abstract Topographic effects on radiation, including both topographic shading and slope effects, are included in the Weather Research and Forecasting (WRF) Model, and here they are made compatible with the immersed boundary method (IBM). IBM is an alternative method for representing complex terrain that reduces numerical errors over sloped terrain, thus extending the range of slopes that can be represented in WRF simulations. The implementation of topographic effects on radiation is validated by comparing land surface fluxes, as well as temperature and velocity fields, between idealized WRF simulations both with and without IBM. Following validation, the topographic shading implementation is tested in a semirealistic simulation of flow over Granite Mountain, Utah, where topographic shading is known to affect downslope flow development in the evening. The horizontal grid spacing is 50 m and the vertical grid spacing is approximately 8–27 m near the surface. Such a case would fail to run in WRF with its native terrain-following coordinates because of large local slope values reaching up to 55°. Good agreement is found between modeled surface energy budget components and observations from the Mountain Terrain Atmospheric Modeling and Observations (MATERHORN) program at a location on the east slope of Granite Mountain. In addition, the model captures large spatiotemporal inhomogeneities in the surface sensible heat flux that are important for the development of thermally driven flows over complex terrain.

54 ENVIRONMENTAL SCIENCES↗

Summary of Disposable Debris Shields (DDS) Analysis for Development of Solid Debris Collection at NIF

Collection of solid debris from the National Ignition Facility (NIF) is being developed both as a diagnostic tool and as a means for measuring nuclear reaction cross sections relevant to the Stockpile Stewardship Program and nuclear astrophysics. The concept is straightforward; following a NIF shot, the debris that is produced as a result of the capsule and hohlraum explosion would be collected and subsequently extracted from the chamber. The number of nuclear activations that occurred in the capsule would then be measured through a combination of radiation detection and radiochemical processing followed by mass spectrometry. Development of the catcher is challenging due to the complex environment of the NIF target chamber. The collector surface is first exposed to a large photon flux, followed by the debris wind that is produced. The material used in the catcher must be mechanically strong in order to withstand the large amount of energy it is exposed to, as well as be chemically compatible with the form and composition of the debris. In addition, the location of the catcher is equally important. If it is positioned too close to the center of the target chamber, it will be significantly ablated, which could interfere with the ability of the debris to reach the surface and stick. If it is too far away, the fraction of the debris cloud collected will be too small to result in a statistically significant measurement. Material, geometric configuration, and location must all be tested in order to design the optimal debris collection system for NIF. One of the first ideas regarding solid debris collection at NIF was to use the disposable debris shields (DDS), which are fielded over the final optics assemblies (FOA) 7 m away from the center of the target chamber. The DDS are meant to be replaced after a certain number of shots, and if the shields could be subsequently analyzed after removal, it would serve as a mechanism for fielding a relatively large collection area through the use of a part meant to be replaced regularly. The solid angle covered by one of the shields is roughly 10 -4 of 4π. If several shields were analyzed at once, it would increase the solid angle of the collection area accordingly. The glass shields consist of ammonia hardened silica with a sol gel coating and kapton tape around the edge. The square sheets are 14-inch on each side. The original shields were 1 mm thick, but it was determined that a thicker shield (3.3 mm) was more effective in preventing debris from reaching the FOA. The Solid Radchem group received two sets of DDS as part of our evaluation of the potential use of the DDS as solid debris collectors. The first set consisted of two 3.3 mm shields, one each from the top and bottom of the chamber (the '3mm set'). The second set consisted of four 1mm shields, one from the top of the chamber and the other three from the bottom (the 'IFSA set'). For each set, the shields were cut into smaller subsamples, which were then imaged using scanning electron microscopy (SEM) followed by chemical leaching and mass spectrometry. The purpose was to evaluate both the quantity and identity of the debris that was present on the DDS surfaces, and to determine if any of the capsule debris was reaching the chamber walls. In addition, potential enhancement due to gravity in the chamber was evaluated by directly comparing shields fielded in the top and bottom of the chamber. Based on the results, the use of the DDS as debris collectors would be evaluated. The results from both sets were presented to the DDS Working Group. The slides are attached to this document. The 3mm set results are presented first, followed by the results from the IFSA set. In both cases it was determined that a small fraction of the overall debris field was collected on the DDS. This means that the debris that is formed during a NIF shot is condensing out of the plasma and depositing on surfaces closer to the target chamber center, or else it is simply falling to the bottom of the chamber. In either case, it was determined that using the DDS, or fielding a debris collector at the chamber wall, was not feasible for solid debris collection at NIF due to the small amount of debris that had been collected. In addition, since the glass shields suffered quite a bit of damage from particles impacting the surface, glass was ruled out as a collection medium.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Hydrogen and OUr Energy Future

In 2003, President George W. Bush announced the Hydrogen Fuel Initiative to accelerate the research and development of hydrogen, fuel cell, and infrastructure technologies that would enable hydrogen fuel cell vehicles to reach the commercial market in the 2020 timeframe. The widespread use of hydrogen can reduce our dependence on imported oil and benefit the environment by reducing greenhouse gas emissions and criteria pollutant emissions that affect our air quality. The Energy Policy Act of 2005, passed by Congress and signed into law by President Bush on August 8, 2005, reinforces Federal government support for hydrogen and fuel cell technologies. Title VIII, also called the 'Spark M. Matsunaga Hydrogen Act of 2005' authorizes more than $3.2 billion for hydrogen and fuel cell activities intended to enable the commercial introduction of hydrogen fuel cell vehicles by 2020, consistent with the Hydrogen Fuel Initiative. Numerous other titles in the Act call for related tax and market incentives, new studies, collaboration with alternative fuels and renewable energy programs, and broadened demonstrations--clearly demonstrating the strong support among members of Congress for the development and use of hydrogen fuel cell technologies. In 2006, the President announced the Advanced Energy Initiative (AEI) to accelerate research on technologies with the potential to reduce near-term oil use in the transportation sector--batteries for hybrid vehicles and cellulosic ethanol--and advance activities under the Hydrogen Fuel Initiative. The AEI also supports research to reduce the cost of electricity production technologies in the stationary sector such as clean coal, nuclear energy, solar photovoltaics, and wind energy.

01 COAL, LIGNITE, AND PEAT↗

Green Pricing Program Marketing Expenditures: Finding the Right Balance

In practice, it is difficult to determine the optimal amount to spend on marketing and administering a green pricing program. Budgets for marketing and administration of green pricing programs are a function of several factors: the region of the country; the size of the utility service area; the customer base and media markets encompassed within that service area; the point or stage in the lifespan of the program; and certainly, not least, the utility's commitment to and goals for the program. All of these factors vary significantly among programs. This report presents data on programs that have funded both marketing and program administration. The National Renewable Energy Laboratory (NREL) gathers the data annually from utility green pricing program managers. Programs reporting data to NREL spent a median of 18.8% of program revenues on marketing their programs in 2008 and 16.6% in 2007. The smallest utilities (those with less than 25,000 in their eligible customer base) spent 49% of revenues on marketing, significantly more than the overall median. This report addresses the role of renewable energy credit (REC) marketers and start-up costs--and the role of marketing, generally, in achieving program objectives, including expansion of renewable energy.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Conceptual Design of a HTS Dipole Insert Based on Bi2212 Rutherford Cable

The U.S. Magnet Development Program (US-MDP) is aimed at developing high-field accelerator magnets with magnetic fields beyond the limits of Nb 3 Sn technology. Recent progress with composite wires and Rutherford cables based on the first generation high-temperature superconductor Bi 2 Sr 2 CaCu 2 O 8-x (Bi2212) allows considering them for this purpose. However, Bi2212 wires and cables are sensitive to transverse stresses and strains, which are large in high-field accelerator magnets. This requires magnet designs with stress management concepts to control azimuthal and radial strains in the coil windings and prevent the degradation of the current carrying capability of Bi2212 conductor or even its permanent damage. This paper describes a novel stress management approach, which was developed at Fermilab for high-field large-aperture Nb 3 Sn accelerator magnets, and is now being applied to high-field dipole inserts based on Bi2212 Rutherford cables. The insert conceptual design and main parameters, including the superconducting wire and cable, as well as the coil stress management structure, key technological steps and approaches, test configurations and their target parameters, are presented and discussed.

43 PARTICLE ACCELERATORS↗