Search NASA⌕ Search

SEARCH · Search NASA

Results for “Assistant”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,009 records · Page 56

Germanium-Assisted Direct Growth of Graphene on Arbitrary Dielectric Substrates for Heating Devices

Direct growth of graphene on dielectric substrates is a prerequsite for the development of graphene-based electronic and optoelectronic devices. However, the current graphene synthesis directly on dielectric substrates always involves metal contamination problem, and the direct production of graphene patterns still remains unattainable and challenging. We propose herein a semiconducting Ge-assisted chemical vapor deposition approach to directly grow monolayer graphene on arbitrary dielectric substrates. By pre-patterning of catalytic Ge layer, the graphene with desired pattern can be achieved with extreme ease. Due to the catalysis of Ge, monolayer graphene is able to form on Ge covered dielectric substrates including SiO 2 /Si, quartz glass and sapphire substrates. Optimization of the process parameters leads to the complete sublimation of catalytic Ge layer during or immediately after monolayer graphene formation, thus resulting in direct deposition of large-area continuous graphene on dielectric substrates. The large-area, highly conductive graphene synthesized on transparent dielectric substrate using the proposed approach has exhibited wide applications, e.g., in defogger and in thermochromic displays, with both devices possessing excellent performances.

36 MATERIALS SCIENCE↗

Seed‐Assisted Growth for Scalable and Efficient Perovskite Solar Modules

Perovskite solar modules (PSMs) have shown remarkable photovoltaic potentials, but they still suffer from large power conversion efficiency (PCE) loss on scale‐up and instability due to inferior uniformity and crystallization over large areas. Herein, the scalable production of efficient and stable PSMs using a suite of all‐scalable fabrication methods featuring a two‐step blade/dip‐coating approach to deposit the perovskite absorber layer is demonstrated. Rubidium chloride is introduced to embed (PbI 2 ) 2 RbCl complex seeds in the first‐deposited PbI 2 precursor, which assists in uniform crystallization of the perovskite layer with high crystallinity and reduced defect density over large areas. Following the optimization of RbCl additives, a champion PSM with 17.9% PCE on a 7.6 × 7.6 cm 2 substrate with a 37 cm 2 aperture area is achieved. Moreover, the RbCl‐incorporated PSMs demonstrate excellent reproducibility and stability under continuous 1 sun illumination. This work shows that the two‐step blade/dip coating is a promising method for producing high‐efficiency and stable PSMs on an industrially relevant scale.

Energy & Fuels↗

Accessing (Ba 1-x Sr x )Al 2 Si 2 O 8 :Eu Phosphors for Solid State White Lighting via Microwave-assisted Preparation: Tuning Emission Color by Coordination Environment

The preparation of Eu 2+ -substituted barium aluminum silicates is achieved using a rapid microwave-assisted preparation. The phase evolution of two BaAl 2 Si 2 O 8 :Eu 2+ polymorphs, the higher temperature hexagonal phase (hexacelsian), and the lower temperature monoclinic phase (celsian), is explored by varying the ramp time and soak time. This preparation method significantly reduces the reaction time needed to form these phases compared to conventional solid state routes. The luminescent properties of the two phases are identified under UV excitation with the hexagonal phase emitting in the UV region (λ em = 372 nm) and the monoclinic phase emitting in the blue region (λ em = 438 nm). The differences in optical properties of the two polymorphs are correlated to the coordination number and arrangement of the alkali earth site. The optical properties of the monoclinic phase can be further tuned through the substitution of Sr 2+ , forming the solid solution (Ba 1–x Sr x )Al 2 Si 2 O 8 :Eu 2+ . Changes in the crystal structure due to Sr 2+ substitution produce a surprising blue-shift in the emission spectrum, which is explained by a greater dispersion of bond lengths in the (Ba/Sr)–O polyhedra. The entire monoclinic solid solution exhibits excellent quantum yields of nearly 90 %, owing to the structural rigidity provided by the highly connected tetrahedral network.

Brgoch, Jakoah↗

Uranium Oxide Nanocrystals by Microwave-Assisted Thermal Decomposition: Electronic and Structural Properties

Uranium oxides have attracted much attention not only in the context of nuclear energy generation but also for their application as pristine catalysts or as supports for other (transition metal) oxides and (precious) metals. Their propensity to adopt high coordination numbers and manifest multiple oxidation states (from +II to +VI) makes them attractive candidates for catalyzed transformation reactions. In this paper, we report a new synthesis route to phase-pure, crystalline UO 2 nanoparticles via microwave-assisted decomposition of a molecular uranium(IV) precursor. Finally, the electronic structure and optical absorption properties of these nanocrystals were investigated using spectroscopic methods to evaluate their suitability for photo(electro)catalytic applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Robust surfactant-assisted one-pot sample preparation for label-free single-cell and nanoscale proteomics

With advanced mass spectrometry (MS)-based proteomics, genome-scale proteome coverage can be achieved from bulk cells. However, such bulk measurement obscures cell to cell heterogeneity, precluding proteome profiling of single cells and small numbers of cells of interest. To address this issue, in recent 5 years there are a surge of small sample preparation methods developed for robust effective collection and processing of single cells and small numbers of cells for in-depth MS-based proteome profiling. Based on their broad accessibility, they can be categorized into two types: specific device- and standard PCR tube- or multi-well plate-based methods. Herein we describe the detailed protocol of our recently developed, easily adoptable, Surfactant-assisted One-Pot (SOP) sample preparation coupled with MS method termed SOP-MS for label-free single-cell and nanoscale proteomics. SOP-MS capitalizes on the combination of a MS-compatible surfactant, DDM (n-Dodecyl-ß-D-maltoside), and standard low-bind PCR tube or multi-well plate for ‘all-in-one’ one-pot sample preparation without sample transfer. With its robust and convenient features, SOP-MS can be readily implemented in any MS laboratory for single-cell and nanoscale proteomics. With further improvements in MS detection sensitivity and sample throughput, we believe that SOP-MS could open an avenue for single-cell proteomics with broad applicability in the biological and biomedical research.

Single-cell proteomics, nanoscale proteomics, SOP-↗

Co-extrusion of dissimilar Al alloys via shear assisted processing and extrusion

Cladded tubes are generally used where two distinct properties are required at the outer and inner part of a tube, for instance, strength and corrosion resistance. In this investigation, shear assisted processing and extrusion (ShAPE) was employed to fabricate bi-metallic tubes from 1100 and 7075, and 1100 and 2024 dissimilar Al alloy combinations. Surface defect-free bi-metallic tubes were fabricated via the ShAPE process. Detailed microstructural characterization of the interface and various locations of the cladded tubes were carried out using light and scanning electron microscopy techniques. A defect-free, metallurgically bonded interface between the cladded layer and high strength Al (7075 and 2024 Al) was observed. Furthermore, hardness and tensile properties of the cladded ShAPE tubes were examined in the as-extruded conditions.

Komarasamy, Mageshwari↗

Enhanced Tensile and Tear Toughness Properties of Thin-Wall Vacuum-Assisted High-Pressure Die-Cast Aural-5 Alloy by Friction Stir Processing

Steadily rising demand for glider weight reduction has driven the development of vacuum-assisted high-pressure die-cast (HPDC) Al-alloys for automotive structural components. Aural-5 is a strontium-modified HPDC alloy utilizing manganese (Mn) to reduce die soldering, eliminating detrimental needle-shaped Fe-bearing ß-phase intermetallic and improving ductility. HPDC Aural-5 contains shrinkage porosity, dendrites with Al-Si eutectic colonies, externally solidified crystals (ESCs), shear-band structure, and large second-phase particulates. Porosity, ESCs and large second-phase particles work as crack initiation sites, negatively impacting tensile properties. In this study, friction stir processing (FSP) is employed for microstructural modification of a thin-walled HPDC Aural-5 by eliminating porosity and breaking down dendrites, second-phase particles, eutectic colonies, ESCs and shear-band structures to create wrought microstructure with homogenized particle distribution. Mechanical property characterization indicates ~30% and ~35% enhancement in yield strength and ductility and associated marked effects on ~69% improvement in tear toughness according to the ASTM B871 test.

Friction stir processing, Aural-5, Strength, Tear ↗

Scaled-Up Fabrication of Thin-Walled ZK60 Tubing using Shear Assisted Processing and Extrusion (ShAPE)

Shear Assisted Processing and Extrusion (ShAPE) has been scaled-up and applied to direct extrusion of thin-walled magnesium tubing. Using ShAPE, billets of ZK60A-T5 were directly extruded into round tubes having an outer diameter of 50.8 mm and wall thickness of 1.52 mm. The severe shearing conditions inherent to ShAPE resulted in microstructural refinement with an average grain size of 3.8μm measured at the midpoint of the tube wall. Tensile testing per ATSM E-8 on specimens oriented parallel to the extrusion direction gave an ultimate tensile strength of 254.4 MPa and elongation of 20.1%. Specimens tested perpendicular to the extrusion direction had an ultimate tensile strength of 297.2 MPa and elongation of 25.0%. Due to material flow effects resulting from the simultaneous linear and rotational shear intrinsic to ShAPE, ram force and electrical power consumption during extrusion were just 40 kN and 11.5 kW respectively. This represents a significant reduction in ram force and power consumption compared to conventional extrusion. As such, there is potential for ShAPE to offer a scalable, lower cost extrusion option with potentially improved bulk mechanical properties.

Direct Extrusion↗

Accurate and Sensitive Analytical Strategy for the Determination of Antimony: Hydrogen Assisted T-Shaped Slotted Quartz Tube-Atom Trap-Flame Atomic Absorption Spectrometry

Antimony is known to have some adverse health effects on human health. Flame atomic absorption spectrometry (FAAS) is a widely used instrumental for the determination of antimony and other metals. However, it lacks the sensitivity to determine these metals at trace levels. This study was aimed at overcoming this setback by using hydrogen assisted T-shaped slotted quartz tube technique to preconcentrate and determine antimony by FAAS. All the system parameters were optimized to enhance the detection power of the system. Under the optimum experimental conditions, the limits of detection and quantification were found to be 0.75 and 2.49 µg L{sup −1}, respectively with R{sup 2} value of 0.9999. Accuracy of the developed method was validated by experimental results agreeing to the certified value of a standard reference material. Recovery studies were also carried out to determine the method’s applicability to tap and mineral water samples, and the results obtained were appreciable.

54 ENVIRONMENTAL SCIENCES↗

Stent-Assisted Coil Embolization of a Wide-Neck Aneurysm of a Persistent Primitive Hypoglossal Artery

Persistent primitive hypoglossal artery (PPHA) represents the second most common carotid-vertebrobasilar anastomosis. The association of PPHA with intracranial aneurysms is not unusual. Treatment of aneurysms located on the PPHA itself is challenging due to the increased risk of ischemic complications secondary to the hypoglossal artery often being the sole contributor of flow to the posterior circulation. We report a case of a wide-neck aneurysm in a PPHA successfully treated using a stent-assisted coil embolization technique.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Minimally Invasive Catheter Procedures to Assist Complicated Pacemaker Lead Extraction and Implantation in the Operating Room

We report on percutaneous catheter procedures in the operating room (OR) to assist complicated manual extraction or insertion of pacemaker (PM) and implantable cardioverter defibrillator leads. We retrospectively reviewed complicated PM revisions and implantations performed between 2004 and 2009 that required percutaneous catheter procedures performed in the OR. The type of interventional procedure, catheter and retrieval system used, venous access, success rates, and procedural complications were analyzed. In 41 (12 female and 29 male [mean age 62 {+-} 17 years]) of 3021 (1.4%) patients, standard manual retrieval of old leads or insertion of new leads was not achievable and thus required percutaneous catheter intervention for retrieval of misplaced leads and/or recanalisation of occluded central veins. Thirteen of 18 (72.2%) catheter-guided retrieval procedures for misplaced (right atrium [RA] or ventricle [RV; n = 3], superior vena cava [n = 2], brachiocephalic vein [n = 5], and subclavian vein [n = 3]) lead fragments in 16 patients were successful. Percutaneous catheter retrieval failed in five patients because there were extremely fixed or adhered lead fragments. Percutaneous transluminal angiography (PTA) of central veins for occlusion or high-grade stenosis was performed in 25 patients. In 22 of 25 patients (88%), recanalization of central veins was successful, thus enabling subsequent lead replacement. Major periprocedural complications were not observed. In the case of complicated manual PM lead implantation or revision, percutaneous catheter-guided extraction of misplaced lead fragments or recanalisation of central veins can be performed safely in the OR, thus enabling subsequent implantation or revision of PM systems in the majority of patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Stent-Assisted Coil Embolization of a Mycotic Renal Artery Aneurysm by Use of a Self-Expanding Neurointerventional Stent

Mycotic aneurysms are uncommon, especially those located in visceral arteries. We present a case of a patient with two visceral mycotic aneurysms due to bacterial endocarditis, one located in right upper pole renal artery and the second in the splenic artery. Both aneurysms were treated as endovascular embolization using microcoils. In the aneurysm located at the renal artery, the technique of stent-assisted coils embolization was preferred to avoid coils migration due to its wide neck. The stent used was the Solitaire AB, which was designed for the treatment of intracranial aneurysms and was used recently in acute stroke as a mechanical thrombectomy device. Complete embolization of the aneurysm was achieved, preserving all the arterial branches without nephrogram defects in the final angiogram.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Value of Duplex Ultrasound Assistance for Thromboaspiration and Dilation of Thrombosed Native Arterio-Venous Fistulae

Purpose: To evaluate the value of duplex ultrasound assistance during thromboaspiration of thrombosed arteriovenous fistulae for haemodialysis. Materials and Methods: We prospectively studied 54 thrombosed native fistulae (23 with total thrombosis and 31 with partial thrombosis), in which we performed manual thromboaspiration guided by ultrasonography associated with fluoroscopy. Results: The fistulae were located in the forearm (n = 39) or in the upper arm (n = 15) of 46 patients. Mean patient age was 65 years, and hypertension was the most common risk factor (74 %). Mean access age was 928 days (range 69-2,290), and most fistulae were on the left side (41 cases, 75.92 %). The success rate was 83 % in the total thrombosis group and 100 % in the partial thrombosis group. Including initial failures, the respective primary patency rates in the total thrombosis group and the partial thrombosis group were, respectively, 83 {+-} 8 % (n = 20) and 87 {+-} 6 % (n = 28) at 1 month, 39 {+-} 10 % (n = 10) and 61 {+-} 8 % (n = 20) at 6 months, and 17 {+-} 8 % (n = 5) and 26 {+-} 8 % (n = 9) at 1 year. The mean decrease of fluoroscopy time with ultrasound was 3 min (range 1-5). The mean decrease of radiation dose was 2.6 Gy cm Superscript-Two (range 0.9-4.3]. Conclusion: Ultrasound is a feasible and useful tool in the management of thrombosed native fistulae, thus decreasing radiation exposure, and has no detrimental effect on success rates.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Change in Imaging Findings on Angiography-Assisted CT During Balloon-Occluded Transcatheter Arterial Chemoembolization for Hepatocellular Carcinoma

PurposeTo evaluate changes in imaging findings on CT during hepatic arteriography (CTHA) and CT during arterial portography (CTAP) by balloon occlusion of the treated artery and their relationship with iodized oil accumulation in the tumor during balloon-occluded transcatheter arterial chemoembolization (B-TACE).MethodsBoth B-TACE and angiography-assisted CT were performed for 27 hepatocellular carcinomas. Tumor enhancement on selective CTHA with/without balloon occlusion and iodized oil accumulation after B-TACE were evaluated. Tumorous portal perfusion defect size on CTAP was compared with/without balloon occlusion. Factors influencing discrepancies between selective CTHA with/without balloon occlusion and the degree of iodized oil accumulation were investigated.ResultsAmong 27 tumors, tumor enhancement on selective CTHA changed after balloon occlusion in 14 (decreased, 11; increased, 3). In 18 tumors, there was a discrepancy between tumor enhancement on selective CTHA with balloon occlusion and the degree of accumulated iodized oil, which was higher than the tumor enhancement grade in all 18. The tumorous portal perfusion defect on CTAP significantly decreased after balloon occlusion in 18 of 20 tumors (mean decrease from 21.9 to 19.1 mm in diameter; p = 0.0001). No significant factors influenced discrepancies between selective CTHA with/without balloon occlusion. Central area tumor location, poor tumor enhancement on selective CTHA with balloon occlusion, and no decrease in the tumorous portal perfusion defect area on CTAP after balloon occlusion significantly influenced poor iodized oil accumulation in the tumor.ConclusionsTumor enhancement on selective CTHA frequently changed after balloon occlusion, which did not correspond to accumulated iodized oil in most cases.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparison of Balloon-Occluded Retrograde Transvenous Obliteration (BRTO) Using Ethanolamine Oleate (EO), BRTO Using Sodium Tetradecyl Sulfate (STS) Foam and Vascular Plug-Assisted Retrograde Transvenous Obliteration (PARTO)

PurposeTo compare the clinical outcomes of balloon-occluded retrograde transvenous obliteration (BRTO) using ethanolamine oleate (EO), BRTO using sodium tetradecyl sulfate (STS) foam, and vascular plug-assisted retrograde transvenous obliteration (PARTO).Materials and MethodsFrom April 2004 to February 2015, ninety-five patients underwent retrograde transvenous obliteration for gastric varices were analyzed retrospectively. BRTO with EO was performed in 49 patients, BRTO with STS foam in 25, and PARTO in 21. Among them, we obtained follow-up data in 70 patients. Recurrence of gastric varices was evaluated by follow-up endoscopy or CT. Medical records were reviewed for the clinical efficacy. Statistical analyses were performed by Kaplan–Meier method, Chi-square, Fisher’s, and Kruskal–Wallis tests.ResultsTechnical and clinical success was 94.7 %. As major complications, a hemoglobinuria and a death due to disseminated intravascular coagulation (DIC) were occurred in two patients with BRTO using EO. Recurrence occurred more frequently in PARTO group (P < 0.05). Recurrence occurred in three patients in BRTO using EO group and four patients in PARTO group with 3.2 and 32.8 % of each expected 1-year recurrence rates. There was no recurrence in BRTO using STS group. Abdominal pain occurred more frequently in BRTO using EO than BRTO using STS foam and PARTO (P < 0.05). Procedure time of PARTO was shorter than two conventional BRTOs (P < 0.05).ConclusionsBRTO using STS foam or PARTO is better than BRTO using EO for treatment of gastric varices in terms of complication or procedure time. However, PARTO showed frequent recurrence of gastric varices during the long-term follow-up rather than BRTO.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Retrospective Comparison of Ultrasound-Assisted Catheter-Directed Thrombolysis and Catheter-Directed Thrombolysis Alone for Treatment of Proximal Deep Vein Thrombosis

BackgroundRecent studies have suggested that catheter-directed thrombolysis (CDT) reduces development of post-thrombotic syndrome (PTS). Ultrasound-assisted CDT (USCDT) might enhance the efficiency of thrombolysis. We aimed to compare USCDT with CDT on efficacy, safety, development of PTS, and quality of life after long-term follow-up.MethodsWe describe a retrospective case series of 94 consecutive patients admitted with iliofemoral or more proximal deep vein thrombosis (DVT) to the University Hospital from 2002 to 2011, treated either with CDT or USCDT. Scheduled follow-up visits took place between April 2013 and January 2014. Venography measured the degree of residual luminal obstruction of the affected veins. Each patient completed the Short Form 36-item health survey assessment and the Venous Insufficiency Epidemiological and Economic Study-Quality of Life/Symptoms questionnaires. PTS was assessed using the Villalta scale.ResultsRisk factors of DVT were equally distributed between groups. In the USCDT group, we observed a significant decline in the duration of thrombolytic treatment (<48 h: 27 vs. 10 %), shortened hospital stay (median 6.0 days (IQR 5.0–9.0) vs. 8.0 (IQR 5.8–12.0)), and less implantation of (intravenous) stents (30 vs. 55 %). There was no difference in patency (76 vs. 79 % fully patent), prevalence of PTS (52 vs. 55 %), or quality of life between groups after long-term follow-up (median 65 months, range: 15–141).ConclusionsIn this observational study, USCDT was associated with shortened treatment duration, shorter hospital stay, and less intravenous stenting, compared to CDT alone without affecting the long-term prevalence of PTS or quality of life.

62 RADIOLOGY AND NUCLEAR MEDICINE↗