Search NASA⌕ Search

SEARCH · Search NASA

Results for “Beam Distribution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,009 records · Page 56

Analytical modeling of equilibrium of strongly anisotropic plasma in tokamaks and stellarators

Theoretical analysis of equilibrium of anisotropic plasma in tokamaks and stellarators is presented. The anisotropy is assumed strong, which includes the cases with essentially nonuniform distributions of plasma pressure on magnetic surfaces. Such distributions can arise at neutral beam injection or at ion cyclotron resonance heating. Then the known generalizations of the standard theory of plasma equilibrium that treat p{sub ‖} and p{sub ⊥} (parallel and perpendicular plasma pressures) as almost constant on magnetic surfaces are not applicable anymore. Explicit analytical prescriptions of the profiles of p{sub ‖} and p{sub ⊥} are proposed that allow modeling of the anisotropic plasma equilibrium even with large ratios of p{sub ‖}/p{sub ⊥} or p{sub ⊥}/p{sub ‖}. A method for deriving the equation for the Shafranov shift is proposed that does not require introduction of the flux coordinates and calculation of the metric tensor. It is shown that for p{sub ⊥} with nonuniformity described by a single poloidal harmonic, the equation for the Shafranov shift coincides with a known one derived earlier for almost constant p{sub ⊥} on a magnetic surface. This does not happen in the other more complex case.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A rate equation approach to gain saturation effects in laser mode calculations

Space exploration and research require large amounts of power. Solar pumped laser systems have been shown to have the potential for meeting the performance requirements necessary for power transmission in space. The successful design of laser systems for these applications will depend, in part, on having a clear understanding of the development of the dynamical processes in the laser cavity and on the effects that changes in physical and design parameters have on laser performance. In particular, it is necessary to know the amplitude and phase distributions of the laser beam at the output aperture when steady state operation is achieved in order to determine the far-field power distribution. The output from the laser will depend on the active medium, the optical environment of the active material and on the gain distribution in the active region as laser action builds up and reaches steady state. An important component in the design process will be a realistic model of the active laser cavity. A computer model of the laser cavity, based on Huygens' principle was developed. The code calculates the amplitude and phase of an optical wave reflected back and forth between the mirrors of a laser cavity. The original code assumes a gain distribution which does not change with the buildup of oscillations in the cavity. A step in the direction of realism is the inclusion of a saturable gain medium in the cavity. The objective is to incorporate saturation effects into the existing computer model.

Roberts, Lila F.↗

The Research Program at RIBRAS (Radioactive Ion Beams in Brasil)-III

A part of the research program developed in the RIBRAS facility over the last four years is presented. Experiments using radioactive secondary beams of light exotic nuclei such as {sup 6}He, {sup 7}Be, {sup 8}Li on several targets have been performed. Elastic angular distributions have been analysed by the Optical Model and four body Continuous Discretized Coupled Channels Calculations (4b-CDCC) and the total reaction cross sections have been obtained. A comparison between the reaction cross sections of {sup 6}He and other stable projectiles with medium-heavy targets was performed. Measurements of the proton transfer reaction {sup 12}C({sup 8}Li,{sup 9}Be){sup 11}B are also presented.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

TH-C-BRD-04: Beam Modeling and Validation with Triple and Double Gaussian Dose Kernel for Spot Scanning Proton Beams

Purpose: To present the validity of our beam modeling with double and triple Gaussian dose kernels for spot scanning proton beams in Nagoya Proton Therapy Center. This study investigates the conformance between the measurements and calculation results in absolute dose with two types of beam kernel. Methods: A dose kernel is one of the important input data required for the treatment planning software. The dose kernel is the 3D dose distribution of an infinitesimal pencil beam of protons in water and consists of integral depth doses and lateral distributions. We have adopted double and triple Gaussian model as lateral distribution in order to take account of the large angle scattering due to nuclear reaction by fitting simulated inwater lateral dose profile for needle proton beam at various depths. The fitted parameters were interpolated as a function of depth in water and were stored as a separate look-up table for the each beam energy. The process of beam modeling is based on the method of MDACC [X.R.Zhu 2013]. Results: From the comparison results between the absolute doses calculated by double Gaussian model and those measured at the center of SOBP, the difference is increased up to 3.5% in the high-energy region because the large angle scattering due to nuclear reaction is not sufficiently considered at intermediate depths in the double Gaussian model. In case of employing triple Gaussian dose kernels, the measured absolute dose at the center of SOBP agrees with calculation within ±1% regardless of the SOBP width and maximum range. Conclusion: We have demonstrated the beam modeling results of dose distribution employing double and triple Gaussian dose kernel. Treatment planning system with the triple Gaussian dose kernel has been successfully verified and applied to the patient treatment with a spot scanning technique in Nagoya Proton Therapy Center.

07 ISOTOPE AND RADIATION SOURCES↗

Ion Beam Measurements of a Dense Plasma Focus Device Using CR 39 Nuclear Track Detectors

The project is carried out using a small Mather type plasma focus device powered by a 15 kV, 30 {mu}F capacitor. The filling gas used is argon. The ion beam generated is investigated by both time resolved and time integrated methods. Investigation on the dynamic of the current sheath is also carried out in order to obtain an optimum condition for ion beam production. The angular distribution of the ion emission is measured at positions of 0 deg. (end-on), 45 deg. and 90 deg. (side-on) by using CR-39 nuclear track detectors. The divergence of the ion beam is also determined using these detectors. A biased ion collector is used for time resolved measurement of the ion beam. Time of flight technique is employed for the determination of the ion beam energy. Average ion beam energy obtained is about 180 keV. The ion beam produced can be used for applications such as material surface modification and ion implantation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

As-grown deep-level defects in n-GaN grown by metal-organic chemical vapor deposition on freestanding GaN

Traps of energy levels E{sub c}-0.26 and E{sub c}-0.61 eV have been identified as as-grown traps in n-GaN grown by metal-organic chemical vapor deposition by using deep level transient spectroscopy of the Schottky contacts fabricated by resistive evaporation. The additional traps of E{sub c}-0.13 and E{sub c}-0.65 eV have been observed in samples whose contacts are deposited by electron-beam evaporation. An increase in concentration of the E{sub c}-0.13 and E{sub c}-0.65 eV traps when approaching the interface between the contact and the GaN film supports our argument that these traps are induced by electron-beam irradiation. Conversely, the depth profiles of as-grown traps show different profiles between several samples with increased or uniform distribution in the near surface below 50 nm. Similar profiles are observed in GaN grown on a sapphire substrate. We conclude that the growth process causes these large concentrations of as-grown traps in the near-surface region. It is speculated that the finishing step in the growth process should be an essential issue in the investigation of the surface state of GaN.

36 MATERIALS SCIENCE↗

On the sensitivity of the goes flare classification to properties of the electron beam in the thick-target model

The collisional thick-target model, wherein a large number of electrons are accelerated down a flaring loop, can be used to explain many observed properties of solar flares. In this study, we focus on the sensitivity of (GOES) flare classification to the properties of the thick-target model. Using a hydrodynamic model with RHESSI-derived electron beam parameters, we explore the effects of the beam energy flux (or total non-thermal energy), the cut-off energy, and the spectral index of the electron distribution on the soft X-rays observed by GOES. We conclude that (1) the GOES class is proportional to the non-thermal energy E {sup α} for α ≈ 1.7 in the low-energy passband (1-8 Å) and ≈1.6 in the high-energy passband (0.5-4 Å); (2) the GOES class is only weakly dependent on the spectral index in both passbands; (3) increases in the cut-off will increase the flux in the 0.5-4 Å passband but decrease the flux in the 1-8 Å passband, while decreases in the cut-off will cause a decrease in the 0.5-4 Å passband and a slight increase in the 1-8 Å passband.

79 ASTRONOMY AND ASTROPHYSICS↗

P-odd and P-even correlations for third particles in ternary fission

Within quantum-mechanical fission theory, P-odd and P-even correlations in angular distributions of products of the ternary fission of nuclei that is induced by polarized cold and thermal neutrons are investigated on the basis of a nonevaporative mechanism of third-particle emission and under the assumption that a two-humped fission barrier exists. It is shown that these correlations for third particles are induced by the analogous correlations for ternary-fission fragments, the latter being transferred to the third particle because of the kinematical conditions of third-particle emission that are associated with the charge and mass asymmetry of fragments. Optimum methods for observing the above correlations for third particles are discussed. The possibility of discovering the emission of prescission neutrons in the fission process against the background of evaporated neutrons by means of studying P-odd and P-even correlations is explored.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Injection of a Self-Consistent Beam at the Spallation Neutron Source

We plan to demonstrate the injection of a self-consistent beam into the Spallation Neutron Source (SNS). Self-consistent beams are defined to be ellipsoidal distributions with uniform density and to retain these properties under all linear transformations. Self-consistent distributions may generate very little halo if realized in practice. Some may also be manipulated to generate flat beams. Self-consistent distributions involve very special relationships between the phase space coordinates, making them difficult to realize experimentally. One self-consistent distribution, the 2D rotating distribution, can be painted into the SNS ring, with slight modification of the lattice. However, it is unknown how robust self-consistent distributions will be under real world transport in the presence of nonlinearities and other collective effects. This paper studies these issues and the mitigation of unwanted effects by applying realistic detailed computational models to the simulation of the injection of rotating beams into SNS. The result is a feasible prescription for the injection of a rotating self-consistent distribution into the SNS ring.

Holmes, Jeffrey↗

SU-E-T-556: Monte Carlo Generated Dose Distributions for Orbital Irradiation Using a Single Anterior-Posterior Electron Beam and a Hanging Lens Shield

Purpose: Various cancers of the eye are successfully treated with radiotherapy utilizing one anterior-posterior (A/P) beam that encompasses the entire content of the orbit. In such cases, a hanging lens shield can be used to spare dose to the radiosensitive lens of the eye to prevent cataracts. Methods: This research focused on Monte Carlo characterization of dose distributions resulting from a single A-P field to the orbit with a hanging shield in place. Monte Carlo codes were developed which calculated dose distributions for various electron radiation energies, hanging lens shield radii, shield heights above the eye, and beam spoiler configurations. Film dosimetry was used to benchmark the coding to ensure it was calculating relative dose accurately. Results: The Monte Carlo dose calculations indicated that lateral and depth dose profiles are insensitive to changes in shield height and electron beam energy. Dose deposition was sensitive to shield radius and beam spoiler composition and height above the eye. Conclusion: The use of a single A/P electron beam to treat cancers of the eye while maintaining adequate lens sparing is feasible. Shield radius should be customized to have the same radius as the patient’s lens. A beam spoiler should be used if it is desired to substantially dose the eye tissues lying posterior to the lens in the shadow of the lens shield. The compromise between lens sparing and dose to diseased tissues surrounding the lens can be modulated by varying the beam spoiler thickness, spoiler material composition, and spoiler height above the eye. The sparing ratio is a metric that can be used to evaluate the compromise between lens sparing and dose to surrounding tissues. The higher the ratio, the more dose received by the tissues immediately posterior to the lens relative to the dose received by the lens.

61 RADIATION PROTECTION AND DOSIMETRY↗

Quality assurance of proton beams using a multilayer ionization chamber system

Purpose: The measurement of percentage depth-dose (PDD) distributions for the quality assurance of clinical proton beams is most commonly performed with a computerized water tank dosimetry system with ionization chamber, commonly referred to as water tank. Although the accuracy and reproducibility of this method is well established, it can be time-consuming if a large number of measurements are required. In this work the authors evaluate the linearity, reproducibility, sensitivity to field size, accuracy, and time-savings of another system: the Zebra, a multilayer ionization chamber system.Methods: The Zebra, consisting of 180 parallel-plate ionization chambers with 2 mm resolution, was used to measure depth-dose distributions. The measurements were performed for scattered and scanned proton pencil beams of multiple energies delivered by the Hitachi PROBEAT synchrotron-based delivery system. For scattered beams, the Zebra-measured depth-dose distributions were compared with those measured with the water tank. The principal descriptors extracted for comparisons were: range, the depth of the distal 90% dose; spread-out Bragg peak (SOBP) length, the region between the proximal 95% and distal 90% dose; and distal-dose fall off (DDF), the region between the distal 80% and 20% dose. For scanned beams, the Zebra-measured ranges were compared with those acquired using a Bragg peak chamber during commissioning.Results: The Zebra demonstrated better than 1% reproducibility and monitor unit linearity. The response of the Zebra was found to be sensitive to radiation field sizes greater than 12.5 × 12.5 cm; hence, the measurements used to determine accuracy were performed using a field size of 10 × 10 cm. For the scattered proton beams, PDD distributions showed 1.5% agreement within the SOBP, and 3.8% outside. Range values agreed within −0.1 ± 0.4 mm, with a maximum deviation of 1.2 mm. SOBP length values agreed within 0 ± 2 mm, with a maximum deviation of 6 mm. DDF values agreed within 0.3 ± 0.1 mm, with a maximum deviation of 0.6 mm. For the scanned proton pencil beams, Zebra and Bragg peak chamber range values demonstrated agreement of 0.0 ± 0.3 mm with a maximum deviation of 1.3 mm. The setup and measurement time for all Zebra measurements was 3 and 20 times less, respectively, compared to the water tank measurements.Conclusions: Our investigation shows that the Zebra can be useful not only for fast but also for accurate measurements of the depth-dose distributions of both scattered and scanned proton beams. The analysis of a large set of measurements shows that the commonly assessed beam quality parameters obtained with the Zebra are within the acceptable variations specified by the manufacturer for our delivery system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of a facility for high-precision irradiation of cells with carbon ions

Purpose: Compared to photons, using particle radiation in radiotherapy reduces the dose and irradiated volume of normal tissues, potentially reducing side effects. The biological effect of dose deposited by particles such as carbon ions, however, differs from that of dose deposited by photons. The inaccuracy in models to estimate the biological effects of particle radiation remains the most important source of uncertainties in particle therapy. Improving this requires high-precision studies on biological effects of particle radiation. Therefore, the authors aimed to develop a facility for reproducible and high-precision carbon-ion irradiation of cells in culture. The combined dose nonuniformity in the lateral and longitudinal direction should not exceed {+-}1.5%. Dose to the cells from particles than other carbon ions should not exceed 5%. Methods: A uniform lateral dose distribution was realized using a single scatter foil and quadrupole magnets. A modulator wheel was used to create a uniform longitudinal dose distribution. The choice of beam energy and the optimal design of these components was determined using GEANT4 and SRIM Monte Carlo simulations. Verification of the uniformity of the dose distribution was performed using a scintillating screen (lateral) and a water phantom (longitudinal). The reproducibility of dose delivery between experiments was assessed by repeated measurements of the spatial dose distribution. Moreover, the reproducibility of dose-response measurements was tested by measuring the survival of irradiated HEK293 cells in three independent experiments. Results: The relative contribution of dose from nuclear reaction fragments to the sample was found to be <5% when using 90 MeV/u carbon ions. This energy still allows accurate dosimetry conforming to the IAEA Report TRS-398, facilitating comparison to dose-effect data obtained with other radiation qualities. A 1.3 mm long spread-out Bragg peak with a diameter of 30 mm was created, allowing the irradiation of cell samples with the specified accuracy. Measurements of the transverse and longitudinal dose distribution showed that the dose variation over the sample volume was {+-}0.8% and {+-}0.7% in the lateral and longitudinal directions, respectively. The track-averaged LET of 132{+-}10 keV/{mu}m and dose-averaged LET of 189{+-}15 keV/{mu}m at the position of the sample were obtained from a GEANT4 simulation, which was validated experimentally. Three separately measured cell-survival curves yielded nearly identical results. Conclusions: With the new facility, high-precision carbon-ion irradiations of biological samples can be performed with highly reproducible results.

60 APPLIED LIFE SCIENCES↗

The extraction of true profiles for TPS commissioning and its impact on IMRT patient-specific QA

The aim of this work is to investigate the clinical impact of detector size effect on patient specific intensity-modulated radiation therapy (IMRT) quality assurance (QA). Two photon beam models, BM6 and BM4, were commissioned using photon beam profiles measured with a 6 mm diameter and a 4 mm diameter ion chambers, respectively. A method was developed to extract the ''true'' cross beam profiles, free of volume averaging effect, using analytic fitting/deconvolution. The method was validated using beam profiles measured with a small (0.8 mm) diode detector for small ({<=}10x10 cm{sup 2}) field sizes. These profiles were used to commission a third beam model (BM08). Planar dose distributions for eight IMRT plans (total of 53 fields) were calculated using the three beam models and measured with a two-dimensional detector array. Analysis using percent dose difference and distance-to-agreement criteria between the calculation and measurement was done to benchmark the performance of each beam model. The average passing rates between calculation and measurement were 93.8%, 98.9%, and 99.4% for BM6, BM4, and BM08, respectively, when 3%/3 mm criteria were used. A gradual increase in passing rates was noticed with the decrease in the size of the detector used to collect commissioning data. When 2%/2 mm criteria were used, the average passing rates increased significantly from 81.6% (BM6) to 92.6% (BM4) and 96.8% (BM08). These results quantify the enhancement of IMRT dose calculation accuracy with the reduction in detector size used for photon beam profiles measurement. Our study indicates that volume averaging effect can significantly affect the results of IMRT patient specific QA. By removing the detector size effect in beam commissioning, excellent passing rates can be achieved with more stringent criteria such as 2%/2 mm. The use of more stringent criteria for IMRT patient specific QA would likely result in higher chances of detecting any dosimetric errors arising from the treatment planning or delivery system.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Analysis of Radiation Transport Due to Activated Coolant in the ITER Neutral Beam Injection Cell

Detailed spatial distributions of the biological dose rate due to a variety of sources are required for the design of the ITER tokamak facility to ensure that all radiological zoning limits are met. During operation, water in the Integrated loop of Blanket, Edge-localized mode and vertical stabilization coils, and Divertor (IBED) cooling system will be activated by plasma neutrons and will flow out of the bioshield through a complex system of pipes and heat exchangers. This paper discusses the methods used to characterize the biological dose rate outside the tokamak complex due to 16 N gamma radiation emitted by the activated coolant in the Neutral Beam Injection (NBI) cell of the tokamak building. Activated coolant will enter the NBI cell through the IBED Primary Heat Transfer System (PHTS), and the NBI PHTS will also become activated due to radiation streaming through the NBI system. To properly characterize these gamma sources, the production of 16 N, the decay of 16 N, and the flow of activated water through the coolant loops were modeled. The impact of conservative approximations on the solution was also examined. Once the source due to activated coolant was calculated, the resulting biological dose rate outside the north wall of the NBI cell was determined through the use of sophisticated variance reduction techniques. The AutomateD VAriaNce reducTion Generator (ADVANTG) software implements methods developed specifically to provide highly effective variance reduction for complex radiation transport simulations such as those encountered with ITER. Using ADVANTG with the Monte Carlo N-particle (MCNP) radiation transport code, radiation responses were calculated on a fine spatial mesh with a high degree of statistical accuracy. In conclusion, advanced visualization tools were also developed and used to determine pipe cell connectivity, to facilitate model checking, and to post-process the transport simulation results.

59 BASIC BIOLOGICAL SCIENCES↗

Experimental Profiling of a Non-truncated Focused Gaussian Beam and Fine-tuning of the Quadratic Phase in the Fresnel Gaussian Shape Invariant

A homodyne profiler is used for recording the intensity distribution of focused non-truncated Gaussian beams. The spatial distributions are obtained at planes in the vicinity of the back-focal plane of a focusing lens placed at different distances from a He–Ne laser beam with a Gaussian intensity profile. Comparisons of the experimental data with those obtained from the analytical equations for an ideal focusing lens allow us to propose formulae to fine-tune the quadratic term in the Fresnel Gaussian shape invariant at each interface of the propagated field. Furthermore, we give analytical expressions to calculate adequately the propagation of the field through an optical system.

42 ENGINEERING↗

Development of spectrally selective imaging system for negative hydrogen ion source

A spectrally selective imaging system has been developed to obtain a distribution of H{sub α} emissions at the extraction region in a hydrogen negative ion source. The diagnostic system consisted of an aspherical lens, optical filters, a fiber image conduit, and a charge coupled device detector was installed on the 1/3-scaled hydrogen negative ion source in the National Institute for Fusion Science. The center of sight line passes beside the plasma grid (PG) surface with the distance of 11 mm, and the viewing angle has coverage 35 mm from the PG surface. Two dimensional H{sub α} distribution in the range up to 20 mm from the PG surface was clearly observed. The reduction area for H{sub α} emission caused by beam extraction was widely distributed in the extraction region near the PG surface.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Studies on remote sensing method of particle size and water density distribution in mists and clouds using laser radar techniques

A method of remote measurement of the particle size and density distribution of water droplets was developed. In this method, the size of droplets is measured from the Mie scattering parameter which is defined as the total-to-backscattering ratio of the laser beam. The water density distribution is obtained by a combination of the Mie scattering parameter and the extinction coefficient of the laser beam. This method was examined experimentally for the mist generated by an ultrasonic mist generator and applied to clouds containing rain and snow. Compared with the conventional sampling method, the present method has advantages of remote measurement capability and improvement in accuracy.

Shimizu, H.↗

The UA9 experimental layout

The UA9 experimental equipment was installed in the CERN-SPS in March '09 with the aim of investigating crystal assisted collimation in coasting mode. Its basic layout comprises silicon bent crystals acting as primary collimators mounted inside two vacuum vessels. A movable 60 cm long block of tungsten located downstream at about 90 degrees phase advance intercepts the deflected beam. Scintillators, Gas Electron Multiplier chambers and other beam loss monitors measure nuclear loss rates induced by the interaction of the beam halo in the crystal. Two Roman pots installed in the path of the deflected particles are equipped with a Medipix detector to reconstruct the transverse distribution of the impinging beam. Finally UA9 takes advantage of an LHC-collimator prototype installed close to the first Roman pot to help in setting the beam conditions and to analyze the efficiency to deflect the beam. This paper describes in details the hardware installed to study the crystal collimation during 2010.

43 PARTICLE ACCELERATORS↗