Search NASA⌕ Search

SEARCH · Search NASA

Results for “CONNECTIONS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,009 records · Page 56

Connection between slow and fast dynamics of molecular liquids around the glass transition

The mean-square displacement (MSD) was measured by neutron scattering at various temperatures and pressures for a number of molecular glass-forming liquids. The MSD is invariant along the glass-transition line at the pressure studied, thus establishing an 'intrinsic' Lindemann criterion for any given liquid. A one-to-one connection between the MSD's temperature dependence and the liquid's fragility is found when the MSD is evaluated on a time scale of {approx}4 ns, but does not hold when the MSD is evaluated at shorter times. The findings are discussed in terms of the elastic model and the role of relaxations, and the correlations between slow and fast dynamics are addressed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Connected and leading disconnected hadronic light-by-light contribution to the muon anomalous magnetic moment with a physical pion mass

We report a lattice QCD calculation of the hadronic light-by-light contribution to the muon anomalous magnetic moment at a physical pion mass. The calculation includes the connected diagrams and the leading, quark-line-disconnected diagrams. We incorporate algorithmic improvements developed in our previous work. The calculation was performed on the 48 3 × 96 ensemble generated with a physical pion mass and a 5.5 fm spatial extent by the RBC and UKQCD Collaborations using the chiral, domain wall fermion formulation. We find a HLbL μ = 5.35(1.35) × 10 –10 , where the error is statistical only. The finite-volume and finite lattice-spacing errors could be quite large and are the subject of ongoing research. Finally, the omitted disconnected graphs, while expected to give a correction of order 10%, also need to be computed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Connecting mechanical properties to hydrogen defects in PAN-based carbon fibers

Atomic-level defects dictate the mechanical properties of carbon fibers and strong correlations have been established between the crystallite sizes and mechanical properties. We recently demonstrated similar correlations with hydrogen content, but reliably quantifying the hydrogen content is not possible using only inelastic neutron scattering experiments. Here, we present prompt-gamma activation analysis (PGAA) experiments collected on 20 commercially available carbon fibers to quantify the hydrogen content of carbon fibers and find correlations between fiber modulus and hydrogen content. We then evaluate the role of hydrogen defect type and connect the PGAA results to both newly acquired and recently reported inelastic neutron scattering experiments. In conclusion, we find that intercalated hydrogen defects are preferentially removed at carbonization temperatures required for high-modulus fibers, potentially giving rise to voids within the carbon fibers that undermine their tensile strength.

36 MATERIALS SCIENCE↗

QCD thermalization: Ab initio approaches and interdisciplinary connections

Heavy-ion collisions at BNL's Relativistic Heavy Ion Collider and CERN's Large Hadron Collider provide strong evidence for the formation of a quark-gluon plasma, with temperatures extracted from relativistic viscous hydrodynamic simulations shown to be well above the transition temperature from hadron matter. Outstanding problems in QCD include how the strongly correlated quark gluon matter forms in a heavy-ion collision, its properties off-equilibrium, and the thermalization process in the plasma. In this work, we review the theoretical progress in this field in weak coupling QCD effective field theories and in strong coupling holographic approaches based on gauge-gravity duality. We outline the interdisciplinary connections of different stages of the thermalization process to non equilibrium dynamics in other systems across energy scales ranging from inflationary cosmology, to strong field QED, to ultracold atomic gases, with emphasis on the universal dynamics of non-thermal and hydrodynamic attractors. We survey measurements in heavy-ion collisions that are sensitive to the early non-equilibrium stages of the collision and discuss the potential for future measurements. We summarize the current state-of-the art in thermalization studies and identify promising avenues for further progress.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Direct 400 Vdc to 1 Vdc power conversion with input series output parallel connection for data center power supplies

Data centers consume an ever-increasing amount of electricity because of the rapid growth of cloud computing and digital information storage. A high voltage point of load (HV POL) converter is proposed to convert the 400-VDC distribution voltage to 1-VDC within a single stage to increase the power conversion efficiency. A six-phase input series output parallel (ISOP) connected structure is implemented for the HV POL. The symmetrical controlled half bridge current doubler is selected as the converter topology in the ISOP structure. The full load efficiency is improved by 4% points compared with state of the art products. A voltage compensator has been designed in order to meet the strict dynamic voltage regulation requirement. A laboratory prototype has been built, and experimental results have been provided to verify the proposed HV POL with a single power conversion stage can meet the dynamic voltage regulation requirement for an on-board power supply with higher efficiency compared to the conventional architecture.

Cui, Yutian↗

20-kW Bi-directional Wireless Power Transfer System with Energy Storage System Connectivity

The severity of the economic impact caused by grid outages has been the driving factor for creating innovative solutions that increases interest for the deployment of distributed energy resources to reduce the impact of grid outages. This study presents a novel way of providing export power using bi-directional wireless power transfer (WPT) systems for ac grid side power and mobile energy storage systems (ESSs) connectivity. The proposed concept here interfaces the EV batteries to the AC grid and also can redirect the power from the stationary ESS to grid, to EV batteries, or both simultaneously; providing the capabilities of an uninterrupted power supply (UPS). Results demonstrate the performance and the functionality of the system with overall efficiencies 93% to 97%, depending on the operating mode.

Onar, Omer↗

High-Efficiency Model Predictive Control for Star-Connected Cascaded H-Bridge STATCOM Under Unbalanced Conditions

This paper presents a high-efficiency model predictive control (HMPC), which is enabled by a sorting approach based on dc capacitor voltages to significantly reduce the exponentially-increasing switching states in cascaded Hbridge (CHB) converters. In addition, a generic discrete-time prediction model for star-connected CHB static synchronous compensator is proposed to address the issues due to either grid and/or load unbalances. Both simulation and hardware-in-loop experimental results are presented to validate the feasibility and effectiveness of the proposed HMPC strategy.

Li, Yufei↗

On the Traffic Impacts of Optimally Controlled Connected and Automated Vehicles

The implementation of connected and automated vehicle (CAV) technologies enables a novel computational framework for real-time control actions aimed at optimizing energy consumption and associated benefits. Several research efforts reported in the literature to date have proposed decentralized control algorithms to coordinate CAVs in various traffic scenarios, e.g., highway on-ramps, intersections, and roundabouts. However, the impact of optimally coordinating CAVs on the performance of a transportation network has not been thoroughly analyzed yet. In this paper, we apply a decentralized optimal control framework in a transportation network and compare its performance to a baseline scenario consisting of human-driven vehicles. We show that introducing of CAVs yields radically improved roadway capacity and network performance.

Zhao, Liuhui↗

MassiveGNN: Efficient Training via Prefetching for Massively Connected Distributed Graphs

Graph Neural Networks (GNN) are indispensable in learning from graph-structured data, yet their rising computational costs, especially on massively connected graphs, pose significant challenges in terms of execution performance. To tackle this, distributed-memory solutions such as partitioning the graph to concurrently train multiple replicas of GNNs are in practice. However, approaches requiring a partitioned graph usually suffer from communication overhead and load imbalance, even under optimal partitioning and communication strategies due to irregularities in the neighborhood minibatch sampling. This paper proposes practical trade-offs for improving the sampling and communication overheads for representation learn- ing on distributed graphs (using popular GraphSAGE architecture) by developing a parameterized prefetch and eviction scheme on top of the state-of-the-art Amazon DistDGL distributed GNN framework, demonstrating about 15–40% improvement in end-to-end training performance on the NERSC Perlmutter supercomputer for various OGB datasets.

Machine Leanring, high performance comptuing, grap↗

Analysis of MTDC Inertia Emulation Impact on Connected AC Systems

The frequency decoupling effect of the voltage source converter (VSC)-based high voltage dc (HVDC) transmission makes frequency support unavailable between two ac subsystems interconnected by the HVDC link. Recently, several algorithms have been proposed and demonstrated to improve the ac system stability by implementing inertia emulation (IE) functions in the HVDC VSC stations. However, the capability of the VSC-HVDC to achieve the IE control is not clear. According to the previous research, the IE control strategy has been studied without concerning the impact of the practical control process, which will introduce some time delay into the IE realization. In this paper, a detailed multi-terminal HVDC VSC control module, including the phase-locked loop (PLL) and low pass filter (LPF), is considered in order to analyze the multi-terminal HVDC network impact on the IE performance. The analysis indicates that the frequency performance of the ac network with IE integrated HVDC transmission can be nearly as good as that directly connected with the ac subsystem which involves a high penetration of conventional generation units, except for the short time delay introduced by the VSC control modules. The effectiveness of IE performance will be compromised if the response delay is significant. The simulation results have verified the analysis.

Wang, Shuyao↗

Medium Voltage (13.8 kV) Transformer-less Grid-Connected DC/AC Converter Design and Demonstration Using 10 kV SiC MOSFETs

Medium voltage (MV) power converters using high voltage (HV) Silicon Carbide (SiC) power semiconductors result in great benefits in weight, size, efficiency and control bandwidth. However, challenges still exist on the components design considering HV insulation and noise immunity requirements in the MV SiC based power converter. A 5-level MMC based transformer-less grid-connected dc/ac converter is developed for 13.8 kV medium voltage grid using 10 kV SiC MOSFETs. The key components, including gate driver with high dv/dt immunity and fast reliable protection, isolated power supply with low parasitic capacitance, voltage/current sensors with high noise immunity, and passives following related insulation standard are provided. A 25 kV dc-link phase-leg is demonstrated, and the experimental results are presented.

Ji, Shiqi↗

Self-stabilizing Connected Components

For the problem of computing the connected components of a graph, this paper considers the design of algorithms that are resilient to transient hardware faults, like bit Hips. More specifically, it applies the technique of self-stabilization. A system is self-stabilizing if, when starting from a valid or invalid state, it is guaranteed to reach a valid state after a finite number of steps. Therefore on a machine subject to a transient fault, a self-stabilizing algorithm could recover if that fault caused the system to enter an invalid state. We give a comprehensive analysis of the valid and invalid states during label propagation and derive algorithms to verify and correct the invalid state. The self-stabilizing label-propagation algorithm performs O (V log V) additional computation and requires O (V) additional storage over its conventional counterpart (and, as such, does not increase asymptotic complexity over conventional label propagation). When run against a battery of simulated fault injection tests, the self-stabilizing label propagation algorithm exhibits more resilient behavior than a triple modular redundancy (TMR) based fault-tolerant algorithm in 80% of cases. From a performance perspective, it also outperforms TMR as it requires fewer iterations in total. Beyond the fault tolerance properties of self-stabilizing label-propagation, we believe, they are useful from the theoretical perspective; and may have other use-cases.

Sao, Piyush↗

Collaborative Fault Tolerant Control of Non-Signalized Intersections for Connected and Autonomous Vehicles

With the potential of increased penetration of connected and autonomous vehicles (CAVs), intersectional signal control faces new challenges in terms of its operation and implementation. One possibility is to fully make use of the communication capabilities of CAVs so that intersectional signal control can be realized by CAVs alone – this leads to non-signalized intersectional operation for traffic networks in urban areas. In this paper, the state-of-the-art on collaborative fault tolerant control schemes for complex systems will be briefly described. This is then followed by the formulation of operational fault tolerant control that realizes the collaborative fault tolerance functionality at CAVs operational level in response to possible individual vehicle faults, where detailed modelling using vehicle movement dynamics will be described together with the construction of fast fault diagnosis and a collaborative fault tolerant control algorithm. A simple example will be given as well to demonstrate the proposed algorithm together with the discussions on other issues such as randomness of the system, communication errors and full energy consideration. These leads to several future directions of the research for the traffic flow control of non-signalized intersections with 100% penetration of CAVs.

Wang, Hong↗

Spatio-Temporal Analysis of HPC I/O and Connection Data

The HPC system consists of a set of layers of software and hardware for I/O and networking. System logs are helpful resources to understand what is going on in the system. A challenge is that it is non-trivial to analyze the logs maintained in various levels of the stack. Independent analysis might lead to an incomplete conclusion due to the limited coverage of each log. This work takes a comprehensive approach to analysis that incorporates the logs in the multiple layers and components, in order to facilitate the detection of anomalous activities. This research aims to identify and predict potential performance bottlenecks in the HPC system, by capturing the temporal variation patterns from heterogeneous, high-dimensional, and non-linear log data. In this paper, we share our preliminary efforts for spatio-temporal analysis of HPC I/O and connection data, with our initial observations from the analysis of one-week HPC log data sets collected from one of NERSC systems.

Choi, Jinhwan↗

Con Connections: Detecting Fraud from Abstracts using Topological Data Analysis

In this paper we present a novel approach for identifying fraudulent papers from their titles and abstracts. The premise of the approach is that there are holes in the presentation of the approach and findings of fraudulent research papers. As an abstract is intended to highlight key features of the approach as well as important conclusions the authors seek to determine if the assumed existence of holes can be identified from analysis of abstracts alone. The data set considered is derived from papers sharing a single author with labels determined based on a formal linguistic analysis of the complete documents. To detect these logical and literary holes we utilize techniques from topological data analysis which summarizes data based on the presence of multi-dimensional, topological holes. We find that, in fact, topological features derived through a combination of techniques in natural language processing and time-series analysis allow for superior detection of the fraudulent papers than the natural language processing tools alone. Thus we conclude that the connections and holes present in the abstracts of research cons contributes to an ability to infer the scientific validity of the corresponding work.

Tymochko, Sarah J.↗

Virtual Cable Impedance based Load Sharing in a Microgrid for Parallel Connected Grid Forming Converters

This paper presents a novel approach to power sharing between direct connected grid-forming converters, utilizing virtual cable impedance and droop-based outer loop control. To enhance stability, resistive droop is implemented, while virtual cable impedance with non-zero resistive and inductive components ensures improved power sharing. The inner loop controller employs a Lyapunov energy function to achieve superior dynamic performance. The proposed control architecture is validated through comprehensive modeling and real-time processor-in-the-loop simulations, demonstrating its robustness and efficiency under various operating conditions. The results highlight the potential of this control strategy to improve the reliability and efficiency of renewable energy systems. Additionally, a comparative analysis with traditional methods underscores the advantages of the proposed approach in terms of stability and performance. The proposed control architecture offers a scalable and flexible solution for grid-forming converters, enabling seamless integration of renewable energy sources. Its robustness and adaptability make it an attractive solution for real-world applications. Furthermore, the approach can be extended to other power electronic systems, enhancing overall system performance and efficiency. By providing a reliable and efficient control strategy, this paper contributes to the advancement of renewable energy systems and their adoption in the energy sector. The proposed control strategy has far-reaching implications for the widespread adoption of renewable energy sources, enabling a more sustainable and efficient energy future. The overall system is modeled in MATLAB/Simulink and PLECS software domain.

grid forming converters (GFM)↗

Stability Analysis of Parallel Connected Bidirectional WPT System

This paper presents a stability analysis of parallel-connected bi-directional series-series resonant network wireless power transfer (WPT), optimized for Electric Vehicle (EV) charging and vehicle-to-grid (V2G) applications. The study addresses critical stability challenges in systems integrated with diverse distributed energy resources (DERs), including photovoltaics, fuel cells, wind turbines, energy storage systems, and the AC grid. The stability of such integrated DC grid systems is paramount for ensuring reliable operation, particularly under varying power flow conditions and dynamic interactions between parallel WPT systems. The analysis included system impedance characterization, state-space modeling, and open and closed-loop stability evaluations. The results demonstrated that the integration of a robust control architecture effectively mitigates instability risks and supports scalable, efficient operation. This work underscores the converter's adaptability and its potential for large-scale deployment in wireless EV charging infrastructures and integrated DC grid systems.

Asa, Erdem [ORNL] (ORCID:0000000190884812)↗

Impact of connected and automated vehicles on traffic flow

In this paper, we investigate the impact of connected and automated vehicles (CAVs) on traffic flow at merging roadways and develop a microscopic simulation framework to explore the implications on fuel consumption and travel time. In this framework, we use optimal control to simulate the behavior of CAVs and the Gipps car following model to capture the behavior of human-driven vehicles. The simulation results show that CAVs can contribute to significant fuel consumption and travel time reduction for diverse traffic conditions under average and high congestion scenarios. Furthermore, we show that CAVs allow for more stable traffic patterns even for high density traffic.

Rios Torres, Jackeline↗