Search NASA⌕ Search

SEARCH · Search NASA

Results for “CONVENTIONAL RADIATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,009 records · Page 56

Identifying the distinct phases of THz waves from K-valley electrons in graphite

The polarity change of THz electromagnetic waves radiated from single-crystalline graphite and polycrystalline graphite films has been studied to identify the main generation mechanism in conventional reflective THz time-domain spectroscopy scheme. The excitation wavelength variation around the K-valley produces no significant changes in THz field strength. We further found that THz waves become fully dispersed without polarity change in lateral detection geometry.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Hydroxypyridinone-based stabilization of Np(IV) enabling efficient U/Np/Pu separations in the Adapted PUREX process

The classical process to recover uranium (U) and plutonium (Pu) from used nuclear fuel using tributyl phosphate (TBP), namely the Plutonium Uranium Redox EXtraction (PUREX) process, is complicated by the persistent presence of neptunium (Np) and thus requires extra purification steps. The concept of Adapted PUREX seeks to achieve Np recovery by adjusting the valence of the metal more effectively, thereby controlling its behavior more precisely. This study introduces the use of an aqueous hydroxypyridinone chelator, 3,4,3-LI(1,2-HOPO) (abbreviated as HOPO), to dictate the behavior of Np for recovery and meanwhile simplify cumbersome reprocessing steps. The interactions between Np and HOPO were probed mechanistically by way of absorption spectrophotometry, in conjunction with cyclic voltammetry. UV–Vis-NIR spectra illustrated the reduction of NpO 2 2+ to Np 4+ , with a fast reaction rate. Cyclic voltammetry revealed quasi-reversible processes between the oxidized and reduced forms of the ligand and its Np complexes. The corresponding heterogeneous rate constants (k 0 ) were estimated from the peak-to-peak separation potentials (ΔE p ), at ~ 4 – 35 μm/s for both HOPO and NpHOPO, with scan rates of 0.01 – 0.4 V/s. Meanwhile, the electromotive force (E MF ) as well as the change of Gibbs free energy (ΔG) were assessed from the half-wave potential (E 1/2 ), demonstrating the completeness of NpO 2 2+ reduction to Np 4+ by HOPO. The cumulative formation constant of the resulting NpHOPO complex (logβ 101 ) was determined by metal competition titration to be 42.0 ± 0.6, corroborating the extraordinarily high affinity of HOPO to tetravalent metal ions. Here, the prowess of valence control by HOPO and the high stability of the formed complex resulted in enhanced separations of Np from U and of Pu from U, with a maximum separation factor of ~7000 for both, nearly 90- and 10300-fold higher, respectively, than the values obtained using conventional PUREX formulae.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Radiation Tolerance and Mechanical Properties of Nanostructured Amorphous-Ceramic/Metal Composites

The objective of this work was to use a radically non-traditional approach to design amorphous-ceramic/metal composites for service in extreme irradiation environments. The project was built on a strong integration among four research teams for materials synthesis and characterization, ion irradiation, mechanical evaluation, and atomic scale modeling. Rather than try to prevent microstructure changes in polycrystalline aggregates, the research team worked to evolve composite systems where one of the constituents is intentionally synthesized in a non-crystalline or “amorphous” state. Because amorphous materials possess no translational symmetry, such alloys do not contain conventional crystal defects such as vacancies, interstitials, or dislocations. These materials offer the possibility of eliminating the root cause responsible for radiation damage in polycrystalline solids - namely the production of point defects and clusters thereof in collision cascades - and could serve as the basis for developing a new class of structural materials with unprecedented resistance to radiation. The amorphous alloys were used to develop advanced amorphous-ceramic/metal composites with greatly improved radiation tolerance and stability above 500oC, and improved mechanical performance by combining the good properties of amorphous materials (high strength and elastic limit) with those of crystalline materials (high toughness, strain hardening). The ceramic component of the composite consisted of a high crystallization temperature and radiation tolerant amorphous alloy composed of Si-O-C, silicon oxycarbide, while the metal layer was Fe and Fe(Cr), chosen to serve as model materials for steel. A prime hypothesis that drove this work is that the composite interface, together with the composite constituents, would provide significantly enhanced radiation tolerance, similar to or superior to those observed in metallic nanolayered structures, in a more engineering relevant material system. As our experimental data and modeling show, we have successfully developed a new class of ceramic/metal composites that can be adapted for engineering applications, thus significantly impacting improved materials performance for advanced nuclear reactors.

36 MATERIALS SCIENCE↗

Microstructural Evolution of NF709 Steel under In-situ Ion Irradiations at Room Temperature to 600 deg. C

NF709 is one of the advanced austenitic stainless steels considered for the advanced reactor systems which are characterized by high temperature, intense radiation and potentially corrosive environments. NF709 is a nitrogen-stabilized and niobium-strengthened alloy, and it provides strength nearly double that for conventional 304 and 316 stainless steels at a temperature range of 600-750 deg. C. In addition, this alloy demonstrates excellent metallurgical stability and high-temperature creep resistance, which is critical for advanced fast-reactor structural materials. Nevertheless, there is very limited irradiation data on NF709 to date, and its radiation-resistance is to be proved. It this paper, we studied the radiation response of NF709 by using the in-situ ion irradiation at the Intermediate Voltage Electron Microscopy (IVEM)- Tandem Facility, located at Argonne National Lab (ANL) and the systematic post-irradiation characterizations using transmission electron microscopy (TEM) were conducted.

36 MATERIALS SCIENCE↗

Roof-integrated radiative air-cooling system to achieve cooler attic for building energy saving

The building attic usually subjects to substantial solar heat gain and has much higher temperature compared to the conditioned living space during the day, especially in summer and in hot areas. Reducing attic temperature can reduce cooling energy consumption in buildings. However, conventional techniques such as cool roof or attic ventilation, suffer from either heating penalty in winter or limited attic temperature reduction. In this work, a new roof-integrated radiative air-cooling system is introduced, which couples radiative sky cooling with attic ventilation to reduce attic temperature. A radiative air cooler with 1.08 m 2 surface area is constructed using a recently developed daytime radiative sky cooling metamaterial [Zhai et al., Science 355, pp. 1062–1066, 2017]. Experimental tests show that sub-ambient air cooling is achieved throughout 24-h day-and-night cycle in a summer day with clear sky conditions. Depending on air flow rates, measured sub-ambient temperature reductions of air are 5–8°C at night and 3–5°C at noon under direct sunlight, respectively. An in-house model is first developed for the radiative air-cooling system, the model is then coupled with EnergyPlus to study annual energy saving of buildings. The performance of the radiative air-cooling system is compared with three reference systems: shingle roof, attic ventilation, and cool roof. Results show that for a single-family house, attic temperature can be substantially reduced by 15.5–21.0°C, varying with attic insulation level, compared to shingle roof on typical summer days. Compared to a shingle roof (solar reflectance 0.25, thermal emittance 0.9) residential building with attic insulations of R-30 (RSI-5.28), R-10 (RSI-1.76), and R-0.8 (RSI-0.14), the roof-integrated radiative air-cooling system can achieve annual cooling energy savings of 0.4–1.5 kWh/m 2 (4.6–18.8%), 1.2–3.6 kWh/m 2 (10.2–41.4%), and 3.7–11.8 kWh/m 2 (26.5–76.1%) respectively.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Protection from Space Radiation

The exposures anticipated for our astronauts in the anticipated Human Exploration and Development of Space (HEDS) will be significantly higher (both annual and carrier) than any other occupational group. In addition, the exposures in deep space result largely from the Galactic Cosmic Rays (GCR) for which there is as yet little experience. Some evidence exists indicating that conventional linear energy transfer (LET) defined protection quantities (quality factors) may not be appropriate [1,2]. The purpose of this presentation is to evaluate our current understanding of radiation protection with laboratory and flight experimental data and to discuss recent improvements in interaction models and transport methods.

Tripathi, R. K.↗

Some implications of linear-quadratic-linear radiation dose-response with regard to hypofractionation

Recent technological advances enable radiation therapy to be delivered in a highly conformal manner to targets located almost anywhere in the body. This capability has renewed the clinical interest in hypofractionation wherein the tumor is delivered a few fractions of very large dose per fraction. Extrapolating clinical experience from conventional regimens to fractions of high dose is important to designing hypofractionated treatments. The concept of biologically effective dose (BED) based on the linear-quadratic (LQ) formulation e{sup -({alpha}D+{beta}D{sup 2})} is a useful tool for intercomparing conventional fractionations but may be hampered if the value of {alpha}/{beta} is dose range dependent and/or when extrapolating to fractions of high dose because the LQ curve bends continuously on the log-linear plot. This does not coincide with what is observed experimentally in many clonogenic cell survival studies at high dose wherein radiation dose-response relationships more closely approximate a straight line. Intercomparison of conventional fractionations with hypofractionated regimens may benefit from BED calculations which instead use a dose range independent linear-quadratic-linear (LQ-L) formulation which better fits the experimental data across a wider range of dose. The dosimetric implications of LQ-L are explored using a simple model which requires only the specification of a dose D{sub T} at which the LQ curve transitions to final linearity and the log{sub e} cell kill per Gy in the final linear portion of the survival curve at high dose. It is shown that the line tangent to the LQ curve at transition dose D{sub T} can often be used to approximate the final slope of the dose response curve. When D{sub T}=2{alpha}/{beta} Gy, the line tangent to the LQ curve at D{sub T} intersects the e{sup -{alpha}}{sup D} and e{sup -{beta}}{sup D{sup 2}} curves at dose {alpha}/{beta} Gy and also closely fits the linear response in the high dose region of some classic in vitro cell survival curves for which the value of {alpha}/{beta} is low. It is hypothesized that D{sub T} will increase as the magnitude of {alpha}/{beta} increases. Examples are presented illustrating how to recognize LQ-L behavior in multifraction isoeffect studies of late responses such as spinal cord and lung. When planning hypofractionated regimens involving reactions with low {alpha}/{beta}, recognizing LQ-L behavior could be important because the dose-response is likely to transition to final linearity within the contemplated range of hypofractional doses.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

DE-NE0000533 2015 final report

The objective of this work was to explore the development of advanced metal/ceramic composites with greatly improved radiation tolerance and stability above 500°C. Such composites combine the good properties of glasses (high strength and elastic limit, corrosion resistance) with those of crystals (high toughness, strain hardening). The ceramic component of the composite consisted of a high crystallization temperature amorphous material composed of Si-O-C while the metal component was Fe, chosen as a model material for steel. The potential impact of this work is the development of a new class of ceramic/metal composites that can be adapted for engineering applications, resulting in dramatically improved materials performance for advanced reactors. We observed that the combination of the composite constituents, as well as the interfaces between them, provided significantly enhanced radiation tolerance. Our research showed the SiOC materials to be extremely radiation tolerant up to 20 displacements per atom (dpa) at 600 °C. The composites of SiOC/Fe were also studies and found to be radiation tolerant up to 5 dpa at 300°C The approached used for the synthesis of these composites (physical vapor deposition) allowed for rapid alloy and composite prototype development and was therefore appropriate for the proposed exploratory study. It does not, however, limit the engineering applicability of the class of materials we have investigated because, in engineering practice, the amorphous ceramic can be made by a variety of chemical methods, including pyrolysis, and the amorphous-ceramic/steel composite can be manufactured by ball milling. The need to develop advanced cladding that does not react with hydrogen or other structural materials is urgent considering past accidents at Fukushima. Ceramic composites are therefore a strong option with stream reactions rates orders of magnitude lower than the Ziracloy currently in use. Different from its crystalline counterparts, the conventional concept of point defects does not apply to amorphous ceramics, so these materials are expect to have higher radiation tolerance. Furthermore, the interfaces created between amorphous-ceramics and metals represent a new type of defect sink that also improves the radiation resistance of the composite’s crystalline component. This project has shown that it is possible to develop high temperature irradiation resistant materials that are in critical need for nuclear applications under extreme conditions where in-core materials have to withstand neutron damage and high temperature.

36 MATERIALS SCIENCE↗

Optimizing Inspection Parameters for Long Stand-Off Detection of SNM

Detection of special nuclear material (SNM) at extended ranges (>100 m) through the utilization of high energy (>20 MeV) bremsstrahlung photons requires optimizing the structure and interrelation of irradiation (beam-on) and detection (counting) periods. Conventional inspection schemes at lower energies and smaller distances primarily operate by pulsing an accelerator at frequencies of 0.1-1 kHz while collecting emitted radiation from the target under inspection for the few milliseconds in between pulses. Simulation and experimental results for long stand-off scenarios with source photons >20 MeV, however, indicate that two primary phenomena--(1) induced photoneutrons in proximity to the accelerator and (2) beam induced activation of air and soil--preclude the use of conventional inspection schemes. By considering the time structure and magnitude of the beam-induced photon and neutron backgrounds, signals of interest from the target, and natural backgrounds, inspection schemes have been developed to maximize signal to noise ratios (SNR). Analysis of the data indicates that the highest SNR values are found with short (2-5 s) irradiations followed by a 1-2 s period of collecting emitted neutron and photon signatures.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

RADIATION EFFECTS IN PHYSICAL AGING OF BINARY As-S AND As-Se GLASSES

Radiation-induced physical aging effects are studied in binary AsxS100-x and AsxSe100-x (30 ≤ x ≤ 42) glasses by conventional differential scanning calorimetry (DSC) method. It is shown that γ-irradiation (Co60 source, ~ 3 MGy dose) of glassy AsxS100-x caused a measurable increase in glass transition temperature and endothermic peak area in the vicinity of glass transition region, which was associated with acceleration of structural relaxation processes in these materials. In contrast to sulfide glasses, the samples of As-Se family did not exhibit any significant changes in DSC curves after γ-irradiation. The observed difference in radiation-induced physical aging between sulfides and selenides was explained by more effective destruction-polymerization transformations and possible metastable defects formation in S-based glassy network.

36 MATERIALS SCIENCE↗

SU-F-P-29: Impact of Oral Contrast Agent for Assisting in Outlining Small Intestine On Pelvic IMAT Dose in Patients with Cervical Cancer

Purpose: As the advanced intensity modulated arc therapy(IMAT) delivery systems becoming a main role of treatment ways, which places even greater demands on delivering accuracy. The impact of oral contrast agent (meglumine diatrizoate) for assisting in outlining the small intestine on pelvic IMAT dose in patients with cervical cancer was investigated. Methods: Ten cervical cancer patients for postoperative radiotherapy underwent CT scans, and the planning target volumes (PTV) and organs at risk (including the small intestine, rectum, bladder, colon and the left and right femoral head) were contoured. The IMAT plans were generated on Oncentra v4.1 planning system for each case, PTV was prescribed to 50.4 Gy in 28 fractions. Then another plan was generated by re-calculating the radiation dose after changing the electron density of the small bowel. The first plan (plan A) was the conventional IMAT plan (with oral contrast agent), and the second one (plan B) specified the electron density of the small bowel (without oral contrast agent). Paired t-test was used to compare the dose distribution between the two plans. Results: The PTV’s D2, D50, D95, V110, conformity index, and homogeneity index of plans A and B were 5610.5 vs. 5611.4 cGy (P=0.175), 5348.5 vs. 5348.0 cGy (P=0.869), 5039 vs. 5042.3 (P=0.518), 6.0% vs. 6.1 %( P=0.886), 0.1269 vs. 0.1271 (P=0.34) and 0.8421 vs. 0.8416 (P=0.598), respectively. The volumes of the small bowel receiving at least 30 Gy (V30) and the minimum dose of 2% volume accepted (D2) for plans A and B were 31.6% vs. 31.9% (P=0.371) and 5067.8 vs. 5085.4 cGy (P=0.377), while rectum V50 of the two plans was 12.4% vs. 12.1% (P=0.489). Conclusion: The oral contrast agent (meglumine diatrizoate) filling the small intestine does not lead to a significant increase in the pelvic IMAT dose in patients with cervical cancer.

60 APPLIED LIFE SCIENCES↗

Comparison of a new noncoplanar intensity-modulated radiation therapy technique for craniospinal irradiation with 3 coplanar techniques

When standard conformal x-ray technique for craniospinal irradiation is used, it is a challenge to achieve satisfactory dose coverage of the target including the area of the cribriform plate, while sparing organs at risk. We present a new intensity-modulated radiation therapy (IMRT), noncoplanar technique, for delivering irradiation to the cranial part and compare it with 3 other techniques and previously published results. A total of 13 patients who had previously received craniospinal irradiation with standard conformal x-ray technique were reviewed. New treatment plans were generated for each patient using the noncoplanar IMRT-based technique, a coplanar IMRT-based technique, and a coplanar volumetric-modulated arch therapy (VMAT) technique. Dosimetry data for all patients were compared with the corresponding data from the conventional treatment plans. The new noncoplanar IMRT technique substantially reduced the mean dose to organs at risk compared with the standard radiation technique. The 2 other coplanar techniques also reduced the mean dose to some of the critical organs. However, this reduction was not as substantial as the reduction obtained by the noncoplanar technique. Furthermore, compared with the standard technique, the IMRT techniques reduced the total calculated radiation dose that was delivered to the normal tissue, whereas the VMAT technique increased this dose. Additionally, the coverage of the target was significantly improved by the noncoplanar IMRT technique. Compared with the standard technique, the coplanar IMRT and the VMAT technique did not improve the coverage of the target significantly. All the new planning techniques increased the number of monitor units (MU) used—the noncoplanar IMRT technique by 99%, the coplanar IMRT technique by 122%, and the VMAT technique by 26%—causing concern for leak radiation. The noncoplanar IMRT technique covered the target better and decreased doses to organs at risk compared with the other techniques. All the new techniques increased the number of MU compared with the standard technique.

61 RADIATION PROTECTION AND DOSIMETRY↗

Microdosimeter Instrument (MIDN-II) for Personnel Dosimetry

This group of collaborators has been funded, by the National Space Biomedical Research Institute (NSBRI) and the U. S. National Aeronautics and Space Administration (NASA) as of February, 2009 to develop a prototypic dosimeter/microdosimeter instrument that measures in real time the radiation risk to personnel in a time varying radiation field of possibly unknown composition. The microdosimetric detectors will be solid-state devices more compact, more rugged than conventional microdosimetric proportional counters used previously in space and will consume less power. The proposed detector will be based on the heritage of the MIDN-MidSTAR microdosimeter launched on the MidSTAR spacecraft on March, 2007, the only solid-state microdosimeter ever flown in space. The system will be suitable for measurements in spacesuits, spacecrafts, remote rovers, or other dynamic or static environments. Measurements as a function of time will not only provide the instantaneous and average absorbed physical dose but also corresponding microdosimetric spectra, dose rates, the dose equivalents, and the dose equivalent rates. Values of the dose equivalents are used to establish relative risks for humans exposed to radiation and to determine regulatory limits. Because these parameters will be available to the astronauts and mission control in real time, these systems can be used not only to quantify exposures and limits, but also to allow appropriate actions to be taken to reduce radiation exposures and their consequences. Earlier prototypes have been used successfully to characterize beams of energetic protons and heavier ions including carbon, oxygen, silicon, titanium, and iron at the NASA Space Radiation Laboratory at Brookhaven National Laboratory. The initial design will be presented and discussed and spectra will be presented.

Pisacane, V. L.↗

Bohmian field theory on a shape dynamics background and Unruh effect

In this paper, we investigate the Unruh radiation in the Bohmian field theory on a shape dynamics background setting. Since metric and metric momentum are real quantities, the integral kernel to invert the Lichnerowicz–York equation for first order deviations due to existence of matter terms turns out to be real. This fact makes the interaction Hamiltonian real. On the other hand, the only contribution to guarantee the existence of Unruh radiation has to come from the imaginary part of the temporal part of the wave functional. We have proved the existence of Unruh radiation in this setting. It is also important that we have found the Unruh radiation via an Unruh–DeWitt detector in a theory where there is no Lorentz symmetry and no conventional space–time structure.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Simulation study of high-current 7 Li 3+ beam acceleration with laser ion source and RFQ linac using direct plasma injection

Accelerator-based neutron sources (ABNS) utilizing the 7 Li(p,n) 7 Be reaction in inverse kinematics offer strong forward-directed neutron emission, making them attractive for compact and clean neutron source with low background neutrons and unwanted radiation. However, practical use of such systems requires lithium ion beam currents that exceed the capability of conventional ion accelerators by two orders of magnitude. In this study, we numerically designed and evaluated a high-current acceleration system based on a direct plasma injection scheme (DPIS), combining a laser ion source (LIS) and a radio-frequency quadrupole (RFQ) linac. The ion extraction optics and RFQ entrance were optimized using IGUN, OPERA, and GPT, demonstrating that over 1.2 A-class beam current can be injected into the RFQ. The RFQ structure was designed under realistic engineering constraints including surface field strength (Kilpatrick factor) and RF power. GPT simulations showed that a 370 mA 7 Li 3+ beam can be successfully accelerated within a ±10 % energy spread. To validate downstream compatibility, we also designed a simplified medium-energy beam transport (MEBT) section and an interdigital H-type (IH) linac, confirming successful acceleration of a 320 mA beam to the total energy of 14 MeV. These results support the feasibility of the DPIS and RFQ approach as a promising solution for compact neutron sources and other high-intensity ion beam applications.

43 PARTICLE ACCELERATORS↗

SU-F-T-30: Comprehensive Dosimetric Characterization of the Novel Direction Modulation Brachytherapy (DMBT) Tandem Applicator Using Monte Carlo Simulations

Purpose: To characterize the dosimetric properties/distributions of the novel proposed direction modulated brachytherapy (DMBT) tandem applicator in combination with 192Ir HDR source, and compare against conventional tandem design, using Monte Carlo simulations. Methods: The proposed DMBT tandem applicator is designed for image-guided adaptive brachytherapy, especially MRI, of cervical cancer. It has 6 peripheral holes of 1.3-mm width, grooved along a 5.4-mm diameter nonmagnetic tungsten alloy rod of density 18.0 g/cc, capable of generating directional dose profiles – leading to enhanced dose sculpting capacity through inverse planning. In-water dosimetric parameters for the DMBT and conventional tandems have been calculated for various radial distances away and around the tandems. For the DMBT tandem, the cumulative dose from the 192Ir source occupying 1) one and 2) all six holes in equal dwell times was calculated and normalized to match the dose rate of the open source (in conventional tandem) at 1 cm from the center. This is done to compare and contrast the characteristic dose distributions to that of the isotropic TG43-based 192Ir source. Results: All dose rates were normalized at 1-cm radius from the center of the applicators, containing source(s). The normalized dose rates at 0.5, 3.0, and 5.0-cm radiuses were then 388, 11.3, and 4.1% for conventional tandem, 657, 8.1, and 2.7% for DMBT tandem with the source in one hole at front entrance, and 436, 10.9, and 3.8% for DMBT tandem with the source in all six holes. For the DMBT tandem case with the source in one hole, the backside transmissions were 47, 2.4, and 0.9%, respectively. Conclusion: The DMBT tandem is able to generate closely similar dosimetric characteristics as that of the single-channel conventional tandem if needed (with the source occupying all six holes), at the same time, generate directional radiation profile(s) for favorably enabling 3D dose sculpting capability.

60 APPLIED LIFE SCIENCES↗

ELECTRON COOLING USING A PULSED AND DITHERING BEAM FROM AN ELECTROSTATIC ELECTRON COOLER

Electron cooling continues to be an invaluable technique to reduce and maintain the emittance in hadron storage rings such as the EIC and EICC where stochastic cooling is inefficient and radiative cooling is negligible. Extending the energy range of electron coolers beyond what is feasible with the conventional, electrostatic approach necessitates the use of RF fields for acceleration and, thus, a bunched electron beam. To experimentally investigate how the relative time structure of the two beams affects the cooling properties, we have set up a pulsed-beam cooling device by adding a synchronized pulsing circuit to the conventional electron source of the CSRm cooler at Institute of Modern Physics. Using both constant and modulated synchronization between electron pulses and ion bunches, we have measured the effects of the electron bunch length and longitudinal ion focusing strength on the temporal evolution of the longitudinal and transverse ion beam profile and demonstrated the detrimental effect of timing jitter as predicted by space-charge theory and simulations. Our experiment suggests a need for further investigations of specific aspects of bunched cooling such as synchro-betatron coupling and phase dithering effects when using short electron bunches to cool longer ion bunches. However, given the comparatively long IBS lifetime of higher-energy proton storage rings like the EIC, slow dithering could potentially provide an option to save cost on the electron cooler linac.

Wang, Haipeng↗

Demonstration of Electron Cooling using a Pulsed Beam from an Electrostatic Electron Cooler

Electron cooling continues to be an invaluable technique to reduce and maintain the emittance in hadron storage rings in cases where stochastic cooling is inefficient and radiative cooling is negligible. Extending the energy range of electron coolers beyond what is feasible with the conventional, electrostatic approach necessitates the use of RF fields for acceleration and, thus, a bunched electron beam. To experimentally investigate how the relative time structure of the two beams affects the cooling properties, we have set up a pulsed-beam cooling device by adding a synchronized pulsing circuit to the conventional electron source of the CSRm cooler at Institute of Modern Physics *. We show the effect of the electron bunch length and longitudinal ion focusing strength on the temporal evolution of the longitudinal and transverse ion beam profile and demonstrate the detrimental effect of timing jitter as predicted by theory and simulations. Compared to actual RF-based coolers, the simplicity and flexibility of our setup will facilitate further investigations of specific aspects of bunched cooling such as synchro-betatron coupling and phase dithering.

Bruker, M. W.↗