Search NASA⌕ Search

SEARCH · Search NASA

Results for “Calibration methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,009 records · Page 56

Simulation evaluation of NIST air-kerma rate calibration standard for electronic brachytherapy: Simulation of NIST air-kerma rate eBT calibration standard

Purpose: Dosimetry for the model S700 50 kV electronic brachytherapy (eBT) source (Xoft, Inc., a subsidiary of iCAD, San Jose, CA) was simulated using Monte Carlo (MC) methods by Rivard et al. [“Calculated and measured brachytherapy dosimetry parameters in water for the Xoft Axxent x-ray source: An electronic brachytherapy source,” Med. Phys. 33, 4020–4032 (2006)] and recently by Hiatt et al. [“A revised dosimetric characterization of the model S700 electronic brachytherapy source containing an anode-centering plastic insert and other components not included in the 2006 model,” Med. Phys. 42, 2764–2776 (2015)] with improved geometric characterization. Additionally, while these studies examined the dose distribution in water, there have not previously been reports of the eBT source calibration methods beyond that recently reported by Seltzer et al. [“New national air-kerma standard for low-energy electronic brachytherapy sources,” J. Res. Natl. Inst. Stand. Technol. 119, 554–574 (2014)]. Therefore, the motivation for the current study was to provide an independent determination of air-kerma rate at 50 cm in air K air (d = 50 cm) using MC methods for the model S700 eBT source. Methods: Using CAD information provided by the vendor and disassembled sources, an MC model was created for the S700 eBT source. Simulations were run using the mcnp6 radiation transport code for the NIST Lamperti air ionization chamber according to specifications by Boutillon et al. [“Comparison of exposure standards in the 10-50 kV x-ray region,” Metrologia 5, 1–11 (1969)], in air without the Lamperti chamber, and in vacuum without the Lamperti chamber. K air (d = 50 cm) was determined using the *F4 tally with NIST values for the mass energy-absorption coefficients for air. Photon spectra were evaluated over 2π azimuthal sampling for polar angles of 0° ≤ θ ≤ 180° every 1°. Volume averaging was averted through tight radial binning. Photon energy spectra were determined over all polar angles in both air and vacuum using the F4 tally with 0.1 keV resolution. A total of 10 11 simulated histories were run for the Lamperti chamber geometry (statistical uncertainty of 0.14%), with 10 10 histories for the in-air and in-vacuum simulations (statistical uncertainty of 0.04%). The total standard uncertainty in the calculated air-kerma rate determination amounted to 6.8%. Results: MC simulations determined the air-kerma rate at 50 cm from the source with the modeled Lamperti chamber to be (1.850 ± 0.126) × 10 -4 Gy/s, which was within the range of K air (d = 50 cm) values (1.67–2.11) × 10 -4 Gy/s measured by NIST. The ratio of the photon spectra in air and in vacuum were in good agreement above 13 keV, and for θ < 150° where the influence of the Kovar sleeve and the Ag epoxy components caused increased scatter in air. Below 13 keV, the ratio of the photon spectra in air to vacuum exhibited a decrease that was attributed to increased attenuation of the photons in air. Across most of the energy range on the source transverse plane, there was good agreement between the authors' simulated spectra and that measured by NIST. Discrepancies were observed above 40 keV where the NIST spectrum had a steeper fall-off towards 50 keV. Conclusions: Through MC simulations of radiation transport, this study provided an independent validation of the measured air-kerma rate at 50 cm in air at NIST for the model S700 eBT source, with mean results in agreement within 3.3%. Lastly, this difference was smaller than the range (i.e., 23%) of the measured values.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-F-P-49: Comparison of Mapcheck 2 Commission for Photon and Electron Beams

Purpose: We will investigate the performance variation of the MapCheck2 detector array with different array calibration and dose calibration pairs from different radiation therapy machine. Methods: A MapCheck2 detector array was calibrated on 3 Elekta accelerators with different energy of photon (6 MV, 10 MV, 15 MV and 18 MV) and electron (6 MeV, 9 MeV, 12 MeV, 15 MeV, 18 MeV and 20 MeV) beams. Dose calibration was conducted by referring a water phantom measurement following TG-51 protocol and commission data for each accelerator. A 10 cm × 10 cm beam was measured. This measured map was morphed by applying different calibration pairs. Then the difference was quantified by comparing the doses and similarity using gamma analysis of criteria (0.5 %, 0 mm). Profile variation was evaluated on a same dataset with different calibration pairs. The passing rate of an IMRT QA planar dose was calculated by using 3 mm and 3% criteria and compared with respect to each calibration pairs. Results: In this study, a dose variation up to 0.67% for matched photons and 1.0% for electron beams is observed. Differences of flatness and symmetry can be as high as 1% and 0.7% respectively. Gamma analysis shows a passing rate ranging from 34% to 85% for the standard 10 × 10 cm field. Conclusion: Our work demonstrated that a customized array calibration and dose calibration for each machine is preferred to fulfill a high standard patient QA task.

60 APPLIED LIFE SCIENCES↗

Quantitative analysis of concrete using portable x-ray fluorescence: Method development and validation

During Decommissioning and Demolition (D&D) activities at SRS, it is important that the building be screened for radionuclides and heavy metals to ensure that the proper safety and disposal metrics are in place. A major source of contamination at DOE facilities is the accumulation of mercury contamination, from nuclear material processing and Liquid Waste System (LWS). This buildup of mercury could possibly cause harm to any demolition crew or the environment should this material be released. The current standard method is to take core samples in various places in the facility and use X-ray fluorescence (XRF) to detect the contamination. This standard method comes with a high financial value due to the security levels of these sample facilities with unknown contamination levels. Here in we propose the use of portable XRF units to detect for this contamination on-site. To validate this method, the instrument has to be calibrated to detect the heavy metal contamination, be both precise with the known elemental concentrations and consistent with its actual results of a sample concrete and pristine contaminant, and be able to detect changes in the sample concrete’s composition. After receiving the various concrete samples with their compositions found by a XRF wave-dispersive method, the calibration factor’s linear regressions were adjusted to give the baseline concentration of the concrete with no contamination. Samples of both concrete and concrete/flyash were evaluated; their standard deviations revealed that the measurements were consistent with the known composition. Finally, the samples were contaminated with different concentrations of sodium tungsten dihydrate, allowed to air dry, and measured. When the contaminated samples were analyzed, the heavy metal contamination was seen within the spectrum of the instrument, but there was not a trend of quantification based on the concentration of the solution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-T-570: New Quality Assurance Method Using Motion Tracking for 6D Robotic Couches

Purpose: To accommodate geometrically accurate patient positioning, a robotic couch that is capable of 6-degrees of freedom has been introduced. However, conventional couch QA methods are not sufficient to enable the necessary accuracy of tests. Therefore, we have developed a camera based motion detection and geometry calibration system for couch QA. Methods: Employing a Visual-Tracking System (VTS, BonitaB10, Vicon, UK) which tracks infrared reflective(IR) markers, camera calibration was conducted using a 5.7 × 5.7 × 5.7 cm{sup 3} cube attached with IR markers at each corner. After positioning a robotic-couch at the origin with the cube on the table top, 3D coordinates of the cube’s eight corners were acquired by VTS in the VTS coordinate system. Next, positions in reference coordinates (roomcoordinates) were assigned using the known relation between each point. Finally, camera calibration was completed by finding a transformation matrix between VTS and reference coordinate systems and by applying a pseudo inverse matrix method. After the calibration, the accuracy of linear and rotational motions as well as couch sagging could be measured by analyzing the continuously acquired data of the cube while the couch moves to a designated position. Accuracy of the developed software was verified through comparison with measurement data when using a Laser tracker (FARO, Lake Mary, USA) for a robotic-couch installed for proton therapy. Results: VTS system could track couch motion accurately and measured position in room-coordinates. The VTS measurements and Laser tracker data agreed within 1% of difference for linear and rotational motions. Also because the program analyzes motion in 3-Dimension, it can compute couch sagging. Conclusion: Developed QA system provides submillimeter/ degree accuracy which fulfills the high-end couch QA. This work was supported by the National Research Foundation of Korea funded by Ministry of Science, ICT & Future Planning. (2013M2A2A7043507 and 2012M3A9B6055201)

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Invited Article: Expanded and improved traceability of vibration measurements by laser interferometry

Traceability to the International System of Units has been established for vibration and shock measurements as specified in international document standards, recommendations, and regulations to ensure product quality, health, and safety. New and upgraded laser methods and techniques developed by national metrology institutes and by leading manufacturers in the past two decades have been swiftly specified as standard methods in the ISO 16063 series of international document standards. In ISO 16063-11:1999, three interferometric methods are specified for the primary calibration of vibration transducers (reference standard accelerometers) in a frequency range from 1 Hz to 10 kHz. In order to specify the same (modified) methods for the calibration of laser vibrometers (ISO 16063-41:2011), their applicability in an expanded frequency range was investigated. Steady-state sinusoidal vibrations were generated by piezoelectric actuators at specific frequencies up to 347 kHz (acceleration amplitudes up to 376 km/s{sup 2}). The displacement amplitude, adjusted by the special interferometric method of coincidence to 158.2 nm (quarter the wavelength of the He-Ne laser light), was measured by the standardized interferometric methods of fringe counting and sine-approximation. The deviations between the measurement results of the three interferometric methods applied simultaneously were smaller than 1 %. The limits of measurement uncertainty specified in ISO 16063-11 between 1 Hz to 10 kHz were kept up to frequencies, which are orders of magnitude greater; the uncertainty limit 0.5 % specified at the reference frequency 160 Hz was not exceeded at 160 kHz. The reported results were considered during the development of ISO 16063-41 by specifying the instrumentation and procedures for performing calibrations of rectilinear laser vibrometers in the frequency range typically between 0.4 Hz and 50 kHz—the interferometric methods may be applied within expanded frequency ranges using refined techniques and procedures. It is concluded that calibration frequencies up to 0.5 MHz are attainable in compliance with the first international document standard for the calibration of laser vibrometers.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The impact of spectroscopic incompleteness in direct calibration of redshift distributions for weak lensing surveys

ABSTRACT Obtaining accurate distributions of galaxy redshifts is a critical aspect of weak lensing cosmology experiments. One of the methods used to estimate and validate redshift distributions is to apply weights to a spectroscopic sample, so that their weighted photometry distribution matches the target sample. In this work, we estimate the selection bias in redshift that is introduced in this procedure. We do so by simulating the process of assembling a spectroscopic sample (including observer-assigned confidence flags) and highlight the impacts of spectroscopic target selection and redshift failures. We use the first year (Y1) weak lensing analysis in Dark Energy Survey (DES) as an example data set but the implications generalize to all similar weak lensing surveys. We find that using colour cuts that are not available to the weak lensing galaxies can introduce biases of up to Δz ∼ 0.04 in the weighted mean redshift of different redshift intervals (Δz ∼ 0.015 in the case most relevant to DES). To assess the impact of incompleteness in spectroscopic samples, we select only objects with high observer-defined confidence flags and compare the weighted mean redshift with the true mean. We find that the mean redshift of the DES Y1 weak lensing sample is typically biased at the Δz = 0.005−0.05 level after the weighting is applied. The bias we uncover can have either sign, depending on the samples and redshift interval considered. For the highest redshift bin, the bias is larger than the uncertainties in the other DES Y1 redshift calibration methods, justifying the decision of not using this method for the redshift estimations. We discuss several methods to mitigate this bias.

79 ASTRONOMY AND ASTROPHYSICS↗

Temperature compensated and self-calibrated current sensor using reference current

A method is described to provide temperature compensation and self-calibration of a current sensor based on a plurality of magnetic field sensors positioned around a current carrying conductor. A reference electrical current carried by a conductor positioned within the sensing window of the current sensor is used to correct variations in the output signal due to temperature variations and aging.

47 OTHER INSTRUMENTATION↗

A TRACER METHOD FOR COMPUTING TYPE IA SUPERNOVA YIELDS: BURNING MODEL CALIBRATION, RECONSTRUCTION OF THICKENED FLAMES, AND VERIFICATION FOR PLANAR DETONATIONS

We refine our previously introduced parameterized model for explosive carbon–oxygen fusion during thermonuclear Type Ia supernovae (SNe Ia) by adding corrections to post-processing of recorded Lagrangian fluid-element histories to obtain more accurate isotopic yields. Deflagration and detonation products are verified for propagation in a medium of uniform density. A new method is introduced for reconstructing the temperature–density history within the artificially thick model deflagration front. We obtain better than 5% consistency between the electron capture computed by the burning model and yields from post-processing. For detonations, we compare to a benchmark calculation of the structure of driven steady-state planar detonations performed with a large nuclear reaction network and error-controlled integration. We verify that, for steady-state planar detonations down to a density of 5 × 10{sup 6} g cm{sup −3}, our post-processing matches the major abundances in the benchmark solution typically to better than 10% for times greater than 0.01 s after the passage of the shock front. As a test case to demonstrate the method, presented here with post-processing for the first time, we perform a two-dimensional simulation of a SN Ia in the scenario of a Chandrasekhar-mass deflagration–detonation transition (DDT). We find that reconstruction of deflagration tracks leads to slightly more complete silicon burning than without reconstruction. The resulting abundance structure of the ejecta is consistent with inferences from spectroscopic studies of observed SNe Ia. We confirm the absence of a central region of stable Fe-group material for the multi-dimensional DDT scenario. Detailed isotopic yields are tabulated and change only modestly when using deflagration reconstruction.

79 ASTRONOMY AND ASTROPHYSICS↗

An Interlaboratory Evaluation of Drift Tube Ion Mobility–Mass Spectrometry Collision Cross Section Measurements

Collision cross section (CCS) measurements resulting from ion mobility-mass spectrometry (IM-MS) experiments provide a promising orthogonal dimension of structural information in MS-based analytical separations. As with any molecular identifier, interlaboratory standardization must precede broad range integration into analytical workflows. In this study, we present a reference drift tube ion mobility mass spectrometer (DTIM-MS) where improvements on the measurement accuracy of experimental parameters influencing IM separations provide standardized drift tube, nitrogen CCS values (DTCCSN2) for over 120 unique ion species with the lowest measurement uncertainty to date. The reproducibility of these DTCCSN2 values are evaluated across three additional laboratories on a commercially available DTIM-MS instrument. The traditional stepped field CCS method performs with a relative standard deviation (RSD) of 0.29% for all ion species across the three additional laboratories. The calibrated single field CCS method, which is compatible with a wide range of chromatographic inlet systems, performs with an average, absolute bias of 0.54% to the standardized stepped field DTCCSN2 values on the reference system. The low RSD and biases observed in this interlaboratory study illustrate the potential of DTIM-MS for providing a molecular identifier for a broad range of discovery based analyses.

54 ENVIRONMENTAL SCIENCES↗

Evaluation of a Reference-Free Collision Cross Section Calibration Strategy for Proteomics Using SLIM-Based High-Resolution Ion Mobility Spectrometry–Mass Spectrometry

Ion mobility spectrometry (IMS) is a gas-phase analytical technique that separates ions with different sizes and shapes and is compatible with mass spectrometry (MS) to provide an additional separation dimension. The rapid nature of the IMS separation combined with the high sensitivity of MS-based detection and the ability to derive structural information on analytes in the form of the property collision cross section (CCS) makes IMS particularly well-suited for characterizing complex samples in -omics applications. In such applications, the quality of CCS from IMS measurements is critical to confident annotation of the detected components in the complex -omics samples. However, most IMS instrumentation in mainstream use requires calibration to calculate CCS from measured arrival times, with the most notable exception being drift tube IMS measurements using multifield methods. The strategy for calibrating CCS values, particularly selection of appropriate calibrants, has important implications for CCS accuracy, reproducibility, and transferability between laboratories. The conventional approach to CCS calibration involves explicitly defining calibrants ahead of data acquisition and crucially relies upon availability of reference CCS values. In this work, we present a novel reference-free approach to CCS calibration which leverages trends among putatively identified features and computational CCS prediction to conduct calibrations post-data acquisition and without relying on explicitly defined calibrants. We demonstrated the utility of this reference-free CCS calibration strategy for proteomics application using high-resolution structures for lossless ion manipulations (SLIM)-based IMS-MS. In conclusion, we first validated the accuracy of CCS values using a set of synthetic peptides and then demonstrated using a complex peptide sample from cell lysate.

59 BASIC BIOLOGICAL SCIENCES↗

Radiometric calibration of optical microscopy and microspectroscopy apparata over a broad spectral range using a special thin-film luminescence standard

Application capabilities of optical microscopes and microspectroscopes can be considerably enhanced by a proper calibration of their spectral sensitivity. We propose and demonstrate a method of relative and absolute calibration of a microspectroscope over an extraordinary broad spectral range covered by two (parallel) detection branches in visible and near-infrared spectral regions. The key point of the absolute calibration of a relative spectral sensitivity is application of the standard sample formed by a thin layer of Si nanocrystals with stable and efficient photoluminescence. The spectral PL quantum yield and the PL spatial distribution of the standard sample must be characterized by separate experiments. The absolutely calibrated microspectroscope enables to characterize spectral photon emittance of a studied object or even its luminescence quantum yield (QY) if additional knowledge about spatial distribution of emission and about excitance is available. Capabilities of the calibrated microspectroscope are demonstrated by measuring external QY of electroluminescence from a standard poly-Si solar-cell and of photoluminescence of Er-doped Si nanocrystals.

36 MATERIALS SCIENCE↗

Calibration of a time-resolved hard-x-ray detector using radioactive sources

A four-channel, time-resolved, hard x-ray detector (HXRD) has been operating at the Laboratory for Laser Energetics for more than a decade. The slope temperature of the hot-electron population in direct-drive inertial confinement fusion experiments is inferred by recording the hard x-ray radiation generated in the interaction of the electrons with the target. Measuring the energy deposited by hot electrons requires an absolute calibration of the hard x-ray detector. A novel method to obtain an absolute calibration of the HXRD using single photons from radioactive sources was developed, which uses a thermoelectrically cooled, low-noise, charge-sensitive amplifier.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Sky Residual Correction

The near-infrared is populated by numerous emission lines radiated from the Earth’s atmosphere, and these emission lines are often several orders of magnitude brighter in intensity than the typical astrophysical science target. The subtraction of these emission lines, sky subtraction, can create large systematic errors in ground-based astronomical spectra effectively limiting the number of usable resolution elements. A more effective sky subtraction, and the reduction of the systematic errors due to the sky subtraction process, is a major hurdle which ground-based astronomy must overcome to increase the amount of usable spectrum, and to be able to observe fainter scientific targets. Large high-quality data sets such as the Sloan Digital Sky Survey (SDSS) in themselves present opportunities for a reduction of the systematic sky subtraction errors through self-calibration. The sky residual correction method of Wild and Hewett is one such self-calibration technique which uses principal component analysis to reduce the systematic sky residual errors present in SDSS spectra. We apply sky residual corrections to the SDSS, Baryon Oscillation Spectroscopic Survey, and Apache Point Observatory Galactic Evolution Experiment data sets to optimize the number of subtraction components, and to quantify the reduction of the systematic errors in the science spectra. Finally as a proof of concept we use the sky-residual-corrected SDSS luminous red galaxy spectra to search for gravitationally lensed emission line Galaxies.

79 ASTRONOMY AND ASTROPHYSICS↗

Conservative self-force correction to the innermost stable circular orbit: Comparison with multiple post-Newtonian-based methods

Barack and Sago [Phys. Rev. Lett. 102, 191101 (2009)] have recently computed the shift of the innermost stable circular orbit (ISCO) of the Schwarzschild spacetime due to the conservative self-force that arises from the finite-mass of an orbiting test-particle. This calculation of the ISCO shift is one of the first concrete results of the self-force program, and provides an exact (fully relativistic) point of comparison with approximate post-Newtonian (PN) computations of the ISCO. Here this exact ISCO shift is compared with nearly all known PN-based methods. These include both 'nonresummed' and 'resummed' approaches (the latter reproduce the test-particle limit by construction). The best agreement with the exact (Barack-Sago) result is found when the pseudo-4PN coefficient of the effective-one-body (EOB) metric is fit to numerical relativity simulations. However, if one considers uncalibrated methods based only on the currently known 3PN-order conservative dynamics, the best agreement is found from the gauge-invariant ISCO condition of Blanchet and Iyer [Classical Quantum Gravity 20, 755 (2003)], which relies only on the (nonresummed) 3PN equations of motion. This method reproduces the exact test-particle limit without any resummation. A comparison of PN methods with the ISCO in the equal-mass case (computed via sequences of numerical relativity initial-data sets) is also performed. Here a (different) nonresummed method also performs very well (as was previously shown). These results suggest that the EOB approach - while exactly incorporating the conservative test-particle dynamics and having several other important advantages - does not (in the absence of calibration) incorporate conservative self-force effects more accurately than standard PN methods. I also consider how the conservative self-force ISCO shift, combined in some cases with numerical relativity computations of the ISCO, can be used to constrain our knowledge of (1) the EOB effective metric, (2) phenomenological inspiral-merger-ringdown templates, and (3) 4PN- and 5PN-order terms in the PN orbital energy. These constraints could help in constructing better gravitational-wave templates. Lastly, I suggest a new method to calibrate unknown PN terms in inspiral templates using numerical-relativity calculations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

VALIDATION, VERIFICATION, AND CALIBRATION THROUGH A CAUSAL LENS

This paper presents an alternative method based on causal inference to perform validation, verification, and calibration of simulation models. While classical validation and verification approaches focus on the identification of the associations between data elements using statistical and machine learning methods, the novel methods in this paper focus instead on the identification of causal relationships between data elements. Statistical and machine learning-based approaches are strictly data-driven, meaning that they provide quantitative comparison measures between datasets without explicitly considering the hypotheses behind them. This can lead to the erroneous conclusion that, if two data sets are close enough, then the models that generated them are similar. In addition, when experimental and simulated data differ to an extent that fails to meet the acceptance criteria, calibration techniques are used to tweak simulation model parameters to reduce the gap between the two types of data. This produces the false expectation that a simulation model will match reality. The methods presented in this paper move away from these strictly data-driven methods for validation and calibration toward more robust, model-driven methods based on causal inference. Causal inference aims to identify the possible mechanisms that might have generated data. Thus, this analysis targets the prediction of the effects when one (or more) of the identified mechanisms are altered. There are many approaches to identify, quantify and illustrate causal relationships. For the scope of this paper, directed graphs are employed as causal models. If the directed graph lacks cycles it is known as a directed acyclic graph (DAG). A node in such a graph represents an observed data element while a directed edge connecting two nodes represents a causal relationship between two variables. The developed causal methods are designed to extract causal models from simulation models and from experimental data. Causal models capture the causal relationships between data elements (e.g., simulated and experimental data). In this context, validation and verification are performed by comparing causal models. The proposed approach does not only inform system analysts on how a simulation model matches real-world data, but also identifies elements of the simulation model that should be revised when discrepancies between simulation and experimental data are observed. Through these causal methods, analysts have a means to identify the portion of the model equation(s) that are behind an edge connecting two variables. Hence, once the structural differences between causal models have been determined, model calibration can occur by changing only those model parameters that impact the identified causal relationships.

97 MATHEMATICS AND COMPUTING↗

Auto-calibrated scanning-angle prism-type total internal reflection microscopy for nanometer-precision axial position determination and optional variable-illumination-depth pseudo total internal reflection microscopy

A method, apparatus, and system for improved VA-TIRFM microscopy. The method comprises automatically controlled calibration of one or more laser sources by precise control of presentation of each laser relative a sample for small incremental changes of incident angle over a range of critical TIR angles. The calibration then allows precise scanning of the sample for any of those calibrated angles for higher and more accurate resolution, and better reconstruction of the scans for super resolution reconstruction of the sample. Optionally the system can be controlled for incident angles of the excitation laser at sub-critical angles for pseudo TIRFM. Optionally both above-critical angle and sub critical angle measurements can be accomplished with the same system.

36 MATERIALS SCIENCE↗

SU-E-J-122: The CBCT Dose Calculation Using a Patient Specific CBCT Number to Mass Density Conversion Curve Based On a Novel Image Registration and Organ Mapping Method in Head-And-Neck Radiation Therapy

Purpose: To develop a CBCT HU correction method using a patient specific HU to mass density conversion curve based on a novel image registration and organ mapping method for head-and-neck radiation therapy. Methods: There are three steps to generate a patient specific CBCT HU to mass density conversion curve. First, we developed a novel robust image registration method based on sparseness analysis to register the planning CT (PCT) and the CBCT. Second, a novel organ mapping method was developed to transfer the organs at risk (OAR) contours from the PCT to the CBCT and corresponding mean HU values of each OAR were measured in both the PCT and CBCT volumes. Third, a set of PCT and CBCT HU to mass density conversion curves were created based on the mean HU values of OARs and the corresponding mass density of the OAR in the PCT. Then, we compared our proposed conversion curve with the traditional Catphan phantom based CBCT HU to mass density calibration curve. Both curves were input into the treatment planning system (TPS) for dose calculation. Last, the PTV and OAR doses, DVH and dose distributions of CBCT plans are compared to the original treatment plan. Results: One head-and-neck cases which contained a pair of PCT and CBCT was used. The dose differences between the PCT and CBCT plans using the proposed method are −1.33% for the mean PTV, 0.06% for PTV D95%, and −0.56% for the left neck. The dose differences between plans of PCT and CBCT corrected using the CATPhan based method are −4.39% for mean PTV, 4.07% for PTV D95%, and −2.01% for the left neck. Conclusion: The proposed CBCT HU correction method achieves better agreement with the original treatment plan compared to the traditional CATPhan based calibration method.

60 APPLIED LIFE SCIENCES↗

Mapping variations of redshift distributions with probability integral transforms

We present a method for mapping variations between probability distribution functions and apply this method within the context of measuring galaxy redshift distributions from imaging survey data. This method, which we name PITPZ for the probability integral transformations it relies on, uses a difference in curves between distribution functions in an ensemble as a transformation to apply to another distribution function, thus transferring the variation in the ensemble to the latter distribution function. This procedure is broadly applicable to the problem of uncertainty propagation. In the context of redshift distributions, for example, the uncertainty contribution due to certain effects can be studied effectively only in simulations, thus necessitating a transfer of variation measured in simulations to the redshift distributions measured from data. We illustrate the use of PITPZ by using the method to propagate photometric calibration uncertainty to redshift distributions of the Dark Energy Survey Year 3 weak lensing source galaxies. For this test case, we find that PITPZ yields a lensing amplitude uncertainty estimate due to photometric calibration error within 1 per cent of the truth, compared to as much as a 30 per cent underestimate when using traditional methods.

79 ASTRONOMY AND ASTROPHYSICS↗