Search NASA⌕ Search

SEARCH · Search NASA

Results for “Composite testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,009 records · Page 56

Toughening of graphite-epoxy composites by interlaminar perforated Mylar films

Fracture and notch strength tests of graphite-epoxy composites showed that unidirectional lay-ups generally exhibit longitudinal cracking before failure, whereas multidirectional lay-ups fail transversely with little longitudinal cracking. A simple qualitative analysis suggested that the higher matrix shear stresses in unidirectional materials cause the longitudinal cracking, and that this cracking was responsible for the high toughness of unidirectional composites. In a series of comparative tests, the interlaminar strength of multi-directional composites was reduced by placing perforated Mylar films between laminae; tests on notched and slotted specimens showed that the interlaminar films promoted delamination and longitudinal cracking near the notches and that, as a result, toughness, notch strength, and impact strength were substantially increased.

Elber, W.↗

Elevated-temperature fracture resistances of monolithic and composite ceramics using chevron-notched bend tests

The quasi-static fracture behaviors of monolithic ceramics (SiC, Si3N4, MgAl2O4), self-reinforced monoliths (acicular grained Si3N4, acicular grained mullite), and ceramic matrix composites (SiC whisker/Al2O3 matrix, TiB2 particulate/SiC matrix, SiC fiber/CVI SiC matrix, Al2O3 fiber/CVI SiC matrix) were measured over the temperature range of 20 to 1400 C. The chevron notched, bend bar test geometry was essential for characterizing the elevated temperature fracture resistances of this wide range of quasi-brittle materials during stable crack growth. Fractography revealed the differences in the fracture behavior of the different materials at the various temperatures. The fracture resistances of the self-reinforced monoliths were comparable to those of the composites and the fracture mechanisms were found to be similar at room temperature. However at elevated temperatures the differences of the fracture behavior became apparent where the superior fracture resistance of the self-reinforced monoliths were attributed to the minor amounts of glassy, intergranular phases which were often more abundant in the composites and affected the fracture behavior when softened by elevated temperatures.

Ghosh, Asish↗

Development of high temperature resistant graphite fiber coupling agents

Surface treatments were investigated as potential coupling agents to improve the elevated temperature shear strength retention of polyimide/graphite and polyphenylquinoxaline/graphite composites. The potential coupling agents were evaluated by fiber strand tensile tests, fiber and composite weight losses at 533 and 588K, and by interlaminar shear strength retention at 533 and 588K. The two surface treatments selected for more extensive evaluation were a coating of Ventromer T-1, a complex organometallic reaction product of titanium tetrachloride and trimethyl borate, and a polyphenylquinoxaline (PPQ) sizing which was pyrolyzed in nitrogen to form a carbonaceous layer on the fiber. Pyrolyzed polyphenylquinoxaline is a satisfactory coupling agent for polyimide/Thornel 300 graphite fiber composites. During 1000 hours aging at 588K such composites lose a little over half their transverse tensile strength, and suffer a slight loss in flexural modulus. No degradation of flexural strength or interlaminar shear strength occured during 1000 hours aging at 588K. None of the coupling agents examined had a markedly beneficial effect with polyphenylquinoxaline composites.

Griffin, R. N.↗

A study of the effects on mice of smoke and gases from controlled fires in simulated aircraft cabins

Male Swiss albino mice were exposed to the pyrolysis products of two fire-retardant materials, a chlorinated aromatic polyamide and a copolymer of vinylidine fluoride and hexafluoropropene. Comparison tests were made with cotton and a 50/50 cotton-polyester composite. In addition, tests were conducted under the presence of CO, and mice were injected intraperitoneally or intramuscularly with aqueous solutions containing dissolved effluents from the pyrolysis of cotton or of chlorinated aromatic polyamide. Results indicate that unique thermodecomposition products of the polymeric materials are more toxic to mice than are other products from cotton under similar controlled conditions.

Moreci, A. P.↗

Radiation and thermal effects on the time-dependent response of T300/934 graphite/epoxy

Experimental studies have suggested that radiation, in conjunction with elevated temperatures, may lead to an exacerbation of the time-dependent response of such materials as T300/934 graphite/epoxy. Attention is given to the results of an investigation into such radiation/temperature effects with this composite system; creep tests were conducted on specimens of both irradiated and nonirradiated T300/934 composite and neat 934 resin specimens, at room temperature and 121 C. The radiation was of 1 MeV electrons, for a total dose of 10,000 Mrads; this simulates a 30-year exposure to radiation in geosynchronous orbit. Irradiation at elevated temperature led to a significant creep-response increase in the initial stages of loading.

Yancey, Robert N.↗

Composite transport wing technology development: Design development tests and advanced structural concepts

Numerous design concepts, materials, and manufacturing methods were investigated for the covers and spars of a transport box wing. Cover panels and spar segments were fabricated and tested to verify the structural integrity of design concepts and fabrication techniques. Compression tests on stiffened panels demonstrated the ability of graphite/epoxy wing upper cover designs to achieve a 35 percent weight savings compared to the aluminum baseline. The impact damage tolerance of the designs and materials used for these panels limits the allowable compression strain and therefore the maximum achievable weight savings. Bending and shear tests on various spar designs verified an average weight savings of 37 percent compared to the aluminum baseline. Impact damage to spar webs did not significantly degrade structural performance. Predictions of spar web shear instability correlated well with measured performance. The structural integrity of spars manufactured by filament winding equalled or exceeded those fabricated by hand lay-up. The information obtained will be applied to the design, fabrication, and test of a full-scale section of a wing box. When completed, the tests on the technology integration box beam will demonstrate the structural integrity of an advanced composite wing design which is 25 percent lighter than the metal baseline.

Griffin, Charles F.↗

Database for the Tribological Properties of Self-Lubricating Materials

A test program to determine the tribological properties of several self-lubricating composites was performed. Testing was done using an LFW-1 Friction and Wear machine. Each material was tested at four load levels (66 N, 133 N, 266 N, and 400 N) under ambient conditions. The coefficient of friction and wear rate was determined for each material, and a relative ranking of the composites was made.

Jett, T. R.↗

Long-Term Leaching Effect on Decay Resistance of Wood-Plastic Composites Treated with Boron Compounds

In this study, water absorption, thickness swelling and decay resistance of thermoplastic composites treated with three types of boron compounds was investigated. Spruce wood flour was treated with boric acid (BA), borax (BX) and mixture of BA–BX, and then was reinforced at two loading rate (20 and 40 wt%) in polymer matrix. Decay test of the composites was performed using with a brown rot fungus Coniophora puteana and a white rot fungus Trametes versicolor both for leached and unleached samples. The morphologic evaluations of decayed samples were done by scanning electron microscopy. Composites containing higher wood flour loading resulted in increased water absorption, thickness swelling, weight loss and moisture content. Fungal decay susceptibility of WPCs was influenced by leaching test for 60 days. Boron compound treated composites showed higher weight loss and moisture content than controls in decay test. All tested performance parameters were considerably increased in BX containing composites.

36 MATERIALS SCIENCE↗

Fabrication and Testing of Active and Adaptive Cyanate Ester Composite Mirrors

The objective of the NASA/Bennett Optical Research Inc. (BOR) NAS8-02008 Phase II Program, which also incorporated ideas developed under the earlier NASA NAS8-01035 Phase 1 Program, was to develop a large mirror fabrication and test facility with emphasis on producing large, light weight active and adaptive optics. A principle objective was to develop mandrels on which to make large composite graphite-filled cyanate ester mirrors, Deliverables were two of these superpolished lightweight active/adaptive optic composite mirrors, one 12" (approx.1/3 meter) in diameter and one 22" (approx.1/2 meter) in diameter. In addition optical superpolishers for mandrels up to 1.2 meters in diameter, test instruments for determining optical figure and scattered light, novel design actuators for making the composite mirrors both active and adaptive, and passive and active means for measuring actuator performance were developed at BOR. We are now installing a superpolisher capable of producing 3 meter diameter mirror/mandrels. All polishers utilize the principle of centrifugal elutriation and produce superpolished mandrels with surface microroughnesses under 1 nm rms.

Bennett, H. E.↗

Evaluating Composite Sampling Methods of Bacillus Spores at Low Concentrations

Restoring facility operations after the 2001 Amerithrax attacks took over three months to complete, highlighting the need to reduce remediation time. The most time intensive tasks were environmental sampling and sample analyses. Composite sampling allows disparate samples to be combined, with only a single analysis needed, making it a promising method to reduce response times. We developed a statistical experimental design to test three different composite sampling methods: 1) single medium single pass composite: a single cellulose sponge samples multiple coupons; 2) single medium multi-pass composite: a single cellulose sponge is used to sample multiple coupons; and 3) multi-medium post-sample composite: a single cellulose sponge samples a single surface, and then multiple sponges are combined during sample extraction. Five spore concentrations of Bacillus atrophaeus Nakamura spores were tested; concentrations ranged from 5 to 100 CFU/coupon (0.00775 to 0.155CFU/cm 2 , respectively). Study variables included four clean surface materials (stainless steel, vinyl tile, ceramic tile, and painted wallboard) and three grime coated/dirty materials (stainless steel, vinyl tile, and ceramic tile). Analysis of variance for the clean study showed two significant factors: composite method (p-value < 0.0001) and coupon material (p-value = 0.0008). Recovery efficiency (RE) was higher overall using the post-sample composite (PSC) method compared to single medium composite from both clean and grime coated materials. RE with the PSC method for concentrations tested (10 to 100 CFU/coupon) was similar for ceramic tile, painted wall board, and stainless steel for clean materials. RE was lowest for vinyl tile with both composite methods. Statistical tests for the dirty study showed RE was significantly higher for vinyl and stainless steel materials, but significantly lower for ceramic tile. These results suggest post-sample compositing can be used to reduce sample analysis time when responding to a Bacillus anthracis contamination event of clean or dirty surfaces.

59 BASIC BIOLOGICAL SCIENCES↗

Effects of sigma-phase formation on some mechanical properties of a wrought nickel-base superalloy (IN-100)

The effect of sigma phase formation on an extruded and forged nickel base superalloy with the composition of the casting alloy IN-100 was studied. By adding only aluminum and titanium to remelt stock, three compositions were produced which had varying propensities for sigma formation. These compositions were given a four step heat treatment and were stress-ruptured or tensile tested. The very sigma prone composition had a shorter rupture life than the sigma-free or moderately sigma prone compositions when tested at 843 and 885 C. Elongation in room temperature tensile tests was considerably lower for the very sigma prone composition than for the other two wrought compositions after prolonged exposure at 732 or 843 C.

Dreshfield, R. L.↗

Preparation Torque Limit for Composites Joined with Mechanical Fasteners

Current design guidelines for determining torque ranges for composites are based on tests and analysis from isotropic materials. Properties of composites are not taken into account. No design criteria based upon a systematic analytical and test analyses is available. This paper is to study the maximum torque load a composite component could carry prior to any failure. Specifically, the torque-tension tests are conducted. NDT techniques including acoustic emission, thermography and photomicroscopy are also utilized to characterize the damage modes.

Thomas, Frank P.↗

Composite mobile system for holographic nondestructive testing

Innovation provides a single system flexible enough to test objects ranging from large amplitude displacement and/or velocities down to extremely small displacements and/or velocities by making only a few minor adjustments in the component arrangements.

Kurtz, R. L.↗

Test and evaluation of Apollo 14 composite casting demonstration specimens 6, 9, and 12, phase 1

Flight and control specimens 6, 9, and 12 from the Apollo 14 composite casting demonstration were evaluated with respect to the degree of dispersion achieved for mixtures of immiscible materials under one-gravity and low gravity environments. The flight and control capsules 6, 9, and 12 contained paraffin and sodium acetate; paraffin, sodium acetate and argon; and paraffin, sodium acetate and 100 micrometer diameter tungsten microspheres, respectively. The evaluation and documentation utilized photographic and microstructure examinations, density measurements, and droplet size and distribution determinations. In addition, theoretical analyses were performed in order to aid in the understanding of the fluid behavior of the specimens during processing and subsequent solidification. A comparison of evaluated data with the theoretical analyses reveals that although the immiscible materials were uniquely dispersed in a low gravity environment, nonuniform dispersions were obtained primarily due to insufficient initial mixing and an essentially unidirectional thermal gradient during cooldown.

Reger, J. L.↗

Test and evaluation of Apollo 14 composite casting demonstration specimens and flight and control samples

The results of experiments 1, 2, and 10 of the Apollo 14 composite casting demonstration are discussed. The purpose of the demonstration, with regard to samples 1 and 2, was to obtain preliminary data on the liquid phase sintering process in a weightless environment. With regard to sample 10, the purpose was to obtain preliminary information on how to achieve uniform dispersion of dense particles on a metal matrix by employing shaking modes or forces in the system when the metal matrix is molten. Results of the demonstrations were interpreted in a quantitative and qualitative manner. For experiment 1 it was found that the tungsten particles were redistributed more uniformly in the flight sample than in the control sample. Experiment 2 results indicate that complete melting may not have occured and thus a high degree of significance cannot be associated with the qualitative results relating to particle redistribution data. The particle-matrix system of experiment 10 was found to be nonwetting.

Fabiniak, R. C.↗

Fabrication and testing of non-graphitic superhybrid composites

A study was conducted to determine the fabrication feasibility and the mechanical properties of adhesively-bonded boron aluminum/titanium and non-graphitic fiber/epoxy resin superhybrid (NGSH) composite laminates for potential aerospace applications. The major driver for this study was the elimination of a potential graphite fiber release problem in the event of a fire. The results of the study show that non-graphitic fibers, such as S-glass and Kevlar 49, may be substituted for the graphite fibers used in superhybrid (SH) composites for some applications. As is to be expected, however, the non-graphitic superhybrids have lower stiffness properties than the graphitic superhybrids. In-plane and flexural moduli of the laminates studied in this program can be predicted reasonably well using linear laminate theory while nonlinear laminate theory is required for strength predictions.

Lark, R. F.↗