Search NASA⌕ Search

SEARCH · Search NASA

Results for “Detection Limit”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,009 records · Page 56

Structural characterization of chitosan-smectite nanocomposite and its application in the development of a novel potentiometric monohydrogen phosphate-selective sensor

Highlights: • Protonated chitosan molecules intercalated into the smectite layers as monolayered arrangement. • A novel HPO{sub 4}{sup 2−} selective potentiometric electrode based on the chitosan-smectite nanocomposite was constructed. • Easy to prepare, low-cost, and highly selective potentiometric sensor. - Abstract: Chitosan-smectite biocomposite was prepared by intercalation of protonated chitosan molecules into the interlayer space of smectite in monolayer arrangement through cation exchange mechanism and the obtained biocomposite was successfully used as an electroactive component in the structure of a PVC membrane potentiometric sensor for the direct and highly selective determination of monohydrogen phosphate ions. The comparative elemental, structural, thermal and morphological analysis of starting-smectite, neat chitosan and chitosan-smectite were investigated by utilizing EDX, XRD, ATR-FTIR, TG/DTG/DTA, SEM and surface area measurement techniques. The optimum membrane composition, detection limit, response time, pH working range and repeatability of the proposed electrode were determined.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Fe-doped ZnO nanoellipsoids for enhanced photocatalytic and highly sensitive and selective picric acid sensor

Highlights: • Low-temperature synthesis of Fe-doped ZnO nanoellipsoids. • Used as efficient photocatalyst for photocatalytic degradation of various dyes (RhB, MB, MO). • Potential scaffold for fabrication of highly sensitive and selective picric acid sensor. - Abstract: Herein, we report the synthesis, characterization, and photocatalytic and sensing capabilities of crystalline Fe-doped ZnO nanoellipsoids (NEs). These NEs were synthesized by a low-temperature simple solution process and were characterized with respect to their structural, morphological, optical, compositional, photocatalytic and sensing properties. The detailed studies confirmed that the synthesized NEs were grown in high density possessing wurtzite hexagonal phase and exhibiting good optical properties. Further, the NEs were applied as a photocatalyst for the photocatalytic degradation of various harmful organic dyes such as methyl orange (MO), rhodamine B (RhB) and methylene blue (MB). Interestingly, it was observed that MB and RhB dyes undergo almost 100% photodegradation with 15–60 min, however, MO dye requires 90 min for the degradation. It is also found that picric acid quenches the luminescence of the NEs (with excitation/emission maxima of 380/392 nm). This finding is exploited in a luminescent assay for picric acid with a 2.9 μM lower detection limit and a linear range that extends from 5 to 60 μmol L{sup −1}. The results show that simply synthesized Fe-doped ZnO nanomaterials can efficiently be used for the photocatalytic and sensing applications.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

A progressive electrochemical sensor for food quality control: Reliable determination of theobromine in chocolate products using a miniaturized boron-doped diamond electrode

In the present paper, a miniaturized boron-doped diamond electrode (BDDE) is proposed as a progressive electrochemical sensor for simple, fast and reliable quantification of dimethylxanthine alkaloid, theobromine (TB). Using cyclic voltammetry, the studied xanthine provided one well-shaped, irreversible and diffusion-controlled oxidation peak at relatively high potentials (+1.2 V vs. Ag/AgCl/3 M KCl reference electrode) in the presence of 0.1 M H2SO4. After selection of suitable experimental conditions, the linear calibration curves for TB were obtained in the concentration range from 0.99 up to 54.5 μM with the sensitivity of 0.07 μA/μM providing both differential pulse (DPV) and square-wave voltammetric (SWV) techniques, respectively. The elaborated voltammetric protocol yielded low detection limits of 0.42 and 0.51 μM accompanied by adequate intra-day repeatability (relative standard deviation of 2.5 and 1.7%) using DPV and SWV procedure, respectively. The interference study revealed the reasonable selectivity when taking the target food samples into account. The practical applicability of the voltammetric protocol using a miniaturized BDDE was verified in the analysis of six commercially available brands of chocolate products with the determined mass percentages of TB ranging from 0.75 to 2.24% and from 0.69 to 2.15% using DPV and SWV procedure, respectively. The obtained results were also in a good agreement with those achieved by reference titration method with potentiometric indication. The progressive electrochemical sensor based on a miniaturized BDDE has appeared to be an attractive candidate for practical applications in food quality control. Besides, the proposed voltammetric protocol presents advantages when compared to others techniques (e.g. chromatography), concerning simplicity, cost, speed of analysis, waste generation (environmentally friendly) and samples pretreatment (only dilution in electrolyte solution prior to analysis). © 2018 Elsevier B.V.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Evaluation of phenolic antioxidant capacity in beverages based on laccase immobilized on screen-printed carbon electrode modified with graphene nanoplatelets and gold nanoparticles

A simple and highly sensitive electrochemical biosensor based on laccase immobilized onto a gold nanoparticles/graphene nanoplatelets-modified screen-printed carbon electrode (LACC/AuNP/GNPl/SPCE) was developed for the determination of hydroquinone (HQ) and other phenolic compounds. The biosensor shows excellent electro-catalytic activity towards oxidation of hydroquinone at a potential of -0.05 V (vs Ag/AgCl, 3 M KCl) in phosphate buffer as supporting electrolyte (0.1 M, pH 7.0) using hydrodynamic amperometry. Analytical characteristics uncover that the LACC/AuNP/GNPl/SPCE comprises a wide linear range for the dependence of the signal on HQ concentrations from 4 to 130 µM with a detection limit (3σ) of 1.5 µM. The repeatability (5 measurements, 100 µM hydroquinone) is ±2% and the reproducibility (5 biosensors, 100 µM hydroquinone) is ±3%. Interference studies of most common compounds with the determination of hydroquinone demonstrated negligible effects. Finally, the biosensor and the analytical method were applied to the determination of phenolic antioxidant capacity (AOC) in wine and blueberry syrup based on Trolox (6‑hydroxy‑2,5,7,8-tetramethylchromane-2-carboxylic acid) and hydroquinone equivalents. The results were evaluated by using their calibration curves which were satisfactory and agreed well with the results obtained by the reference method Trolox Equivalent Antioxidant Capacity assay (TEAC-Assay).

60 APPLIED LIFE SCIENCES↗

Partitioning of tramp elements Cu and Si in a Ni-based superalloy and their effect on creep properties

An alloy's processing history, including melting, remelting or the choice of stock material, affects its purity and eventually involves tramp element pickup or retention. Herein, variants of a novel Ni-based superalloy were manufactured with different levels of purity. The so-called low purity alloys contained 0.138 wt. % Cu and 0.019 wt. % Si while the Cu and Si levels were below x-ray fluorescence (XRF) detection limits of 0.003 and 0.010 wt. %, respectively, in the high purity ingots. Atom-probe tomography (APT) was carried out and revealed Si partitioning at the following interfaces: grain boundaries, MC carbide/γ, M 3 B 2 boride/$γ$ and M 3 B 2 boride/$γ$'. Copper was found to primarily segregate to the $γ$' precipitates. An average of 2.4 × decrease in creep life and 4.3 × decrease in creep ductility was measured in the low purity alloys, which was attributed to the embrittlement caused by Si segregation to grain boundaries. Furthermore, the positive effect of B on the creep properties was mitigated by the presence of Si. Thermodynamic predictions for the matrix and γ' precipitate compositions represented the trends observed experimentally although the extent of preferential partitioning lacks accuracy. Monte Carlo simulations were performed to describe the partitioning of Cu and Si atoms to either $γ$ or $γ$' phases.

36 MATERIALS SCIENCE↗

Study of the loss of xenon scintillation in xenon-trimethylamine mixtures

This work investigates the capability of TMA ((CH 3 ) 3 N) molecules to shift the wavelength of Xe VUV emission (160-188 nm) to a longer, more manageable, wavelength (260-350 nm). Light emitted from a Xe lamp was passed through a gas chamber filled with Xe-TMA mixtures at 800 Torr and detected with a photomultiplier tube. Using bandpass filters in the proper transmission ranges, no reemitted light was observed experimentally. Considering the detection limit of the experimental system, if reemission by TMA molecules occurs, it is below 0.3% of the scintillation absorbed in the 160-188 nm range. An absorption coefficient value for xenon VUV light by TMA of 0.43 ± 0.03 cm -1 Torr -1 was also obtained. These results can be especially important for experiments considering TMA as a molecular additive to Xe in large volume optical time projection chambers.

36 MATERIALS SCIENCE↗

An Automated Ultraclean Ion Exchange Separation Method for the Determinations of 232Th and 238U in Copper using Inductively Coupled Plasma Mass Spectrometry

This work presents a novel automated analytical method developed for high throughput ultrasensitive determinations of Th and U in copper using inductively coupled plasma mass spectrometry (ICP-MS). The method is based on the use of ultra clean sample preparation procedures including the use of a fully automated off-line chromatography system for the extraction and pre-concentration of the analytes prior to ICP-MS analysis. The separation system is equipped with a single reusable chromatographic column that, with the rigorously clean procedures developed herein, provided a low carryover, low background, and reproducible automated separation method. Isotope dilution methods were used for quantitation. Method Detection Limits (MDLs) of 3.7 and 9.4 fg·g-1 were obtained for the quantitation of 232Th and 238U in copper, respectively, corresponding to activities of 0.0148 and 0.116 microBq·kg-1 for 232Th and 238U, respectively. The analytical method provided high and reproducible tracer recoveries. The use of an automated system significantly reduced the extremely tedious active work time required for the chemist (by ca. 80%) relative to manually performing the separation. This method could be adapted to other critical sample matrices requiring the utmost in high throughput clean chemistry procedures for automated ultrasensitive analyses.

Arnquist, Isaac J.↗

MicroRaman measurements for nuclear fuel reprocessing applications

Treatment and reuse of used nuclear fuel is a key component in closing the nuclear fuel cycle. Solvent extraction reprocessing methods that have been developed contain various steps tailored to the separation of specific radionuclides, which are highly dependent upon solution properties. The instrumentation used to monitor these processes must be robust, require little or no maintenance, and be able to withstand harsh environments such as high radiation fields and aggressive chemical matrices. Our group has been investigating the use of optical spectroscopy for the on-line monitoring of actinides, lanthanides, and acid strength within fuel reprocessing streams. This paper will focus on the development and application of a new MicroRaman probe for on-line real-time monitoring of the U(VI)/nitrate ion/nitric acid in solutions relevant to used nuclear fuel reprocessing. Previous research has successfully demonstrated the applicability on the macroscopic scale, using sample probes requiring larger solution volumes. In an effort to minimize waste and reduce dose to personnel, we have modified this technique to allow measurement at the microfluidic scale using a Raman microprobe. Under the current sampling environment, Raman samples typically require upwards of 10 mL and larger. Using the new sampling system, we can sample volumes at 10 μL or less, which is a scale reduction of over 1,000 fold in sample size. Finally, this paper will summarize our current work in this area including: comparisons between the macroscopic and microscopic probes for detection limits, optimized channel focusing, and application in a flow cell with varying levels of HNO 3 , and UO 2 (NO 3 ) 2 .

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A method for direct, semi-quantitative analysis of gas phase samples using gas chromatography-inductively coupled plasma-mass spectrometry

A new and complete GC–ICP-MS method is described for direct analysis of trace metals in a gas phase process stream. The proposed method is derived from standard analytical procedures developed for ICP-MS, which are regularly exercised in standard ICP-MS laboratories. In order to implement the method, a series of empirical factors were generated to calibrate detector response with respect to a known concentration of an internal standard analyte. Calibrated responses are ultimately used to determine the concentration of metal analytes in a gas stream using a semi-quantitative algorithm. The method was verified using a traditional gas injection from a GC sampling valve and a standard gas mixture containing either a 1 ppm Xe + Kr mix with helium balance or 100 ppm Xe with helium balance. Data collected for Xe and Kr gas analytes revealed that agreement of 6–20% with the actual concentration can be expected for various experimental conditions. To demonstrate the method using a relevant “unknown” gas mixture, experiments were performed for continuous 4 and 7 hour periods using a Hg-containing sample gas that was co-introduced into the GC sample loop with the xenon gas standard. System performance and detector response to the dilute concentration of the internal standard were pre-determined, which allowed semi-quantitative evaluation of the analyte. The calculated analyte concentrations varied during the course of the 4 hour experiment, particularly during the first hour of the analysis where the actual Hg concentration was under predicted by up to 72%. Calculated concentration improved to within 30–60% for data collected after the first hour of the experiment. Similar results were seen during the 7 hour test with the deviation from the actual concentration being 11–81% during the first hour and then decreasing for the remaining period. The method detection limit (MDL) was determined for the mercury by injecting the sample gas into the system following a period of equilibration. The MDL for Hg was calculated as 6.8 μg · m -3 . This work describes the first complete GC–ICP-MS method to directly analyze gas phase samples, and detailed sample calculations and comparisons to conventional ICP-MS methods are provided.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Quantification of manganese for ChemCam Mars and laboratory spectra using a multivariate model

In this work, we report a new calibration model for manganese using the laser-induced breakdown spectroscopy instrument that is part of the ChemCam instrument suite onboard the NASA Curiosity rover. The model has been trained using an expanded set of 523 manganese-bearing rock, mineral, metal ore, and synthetic standards. The optimal calibration model uses the Partial Least Squares (PLS) and Least Absolute Shrinkage and Selection Operator (LASSO) multivariate techniques, with a novel “double blending” technique. We determined the detection limit for manganese is 82 ppm using a method blank procedure and is possibly as low as 27 ppm based on visual inspection of the spectra. Based on a representative test set consisting of measurements on 93 standards, the double blended multivariate model shows a Root Mean Squared Error of Prediction (RMSEP) accuracy of 1.39 wt% MnO for the full blended model. Employing a local RMSEP estimate where the model performance is evaluated based on nearby test samples, the accuracy is 0.03 wt% at the quantification limit (0.05 wt% MnO), 0.4 wt% accuracy at 1.0 wt% MnO, and 4.4 wt% accuracy at 100 wt% MnO. Precision is estimated using the standard deviation of the test set measurements, and is ±0.01 wt% MnO at the quantification limit, ±0.09 wt% MnO at 1.0 wt% MnO, and ± 2.1 wt% MnO at 100 wt% MnO (all 1 standard deviation). This new calibration is important for understanding the variation of manganese in the bedrock with the Curiosity rover on Mars, which provides insight into past redox conditions on Mars.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Catalytic hydrogen sensing using microheated platinum nanoparticle-loaded graphene aerogel

We present that low power catalytic hydrogen sensors are fabricated by functionalizing low power polysilicon microheaters with platinum nanoparticle catalyst loaded in a high surface area graphene aerogel support. Fabrication and characterization of the polysilicon microheaters are described. The platinum nanoparticle-loaded graphene aerogel is characterized by transmission electron microscopy, scanning electron microscopy, and energy dispersive X-ray spectroscopy. Finally, the catalytic hydrogen sensors consume as little as 2.2 mW of power, have sensitivity of 1.6%/10,000 ppm hydrogen, a t90 response and recovery time of 0.97 s and 0.72 s, respectively, a lower detection limit of approximately 65 ppm, and negligible cross sensitivity to methane, n-pentane, and diethylether.

08 HYDROGEN↗

Compact TDLAS based optical sensor for ppb-level ethane detection by use of a 3.34 μm room-temperature CW interband cascade laser

A mid-infrared ethane (C 2 H 6 ) sensor based on a wavelength modulation spectroscopy (WMS) technique was developed using a thermoelectrically cooled (TEC), continuous-wave (CW) interband cascade laser (ICL) emitting at 3.34 μm and a dense multi-pass gas cell (MPGC, 17 × 6.5 × 5.5 cm 3 ) with a 54.6 m optical path length. A compact optical sensor system with a physical size of 35.5 × 18 × 12.5 cm 3 was designed and constructed. An ICL was employed for targeting a strong C 2 H 6 line at 2996.88 cm -1 at <100 Torr gas pressure in the fundamental absorption band of C 2 H 6 . The sensor performance, including the minimum detection limit (MDL) and the stability were improved by reducing the effect of laser power drift by means of the 2f/1f-WMS technique. A MDL of ~1.2 parts per billion (ppbv) for 2f-WMS and ~1.0 ppbv for 2f/1f-WMS were achieved, respectively, with a measurement time of 4 s. The MDL was further improved from 299 pptv (@108 s for 2f-WMS) to 239 pptv (@208 s for 2f/1f-WMS), based on an Allan deviation analysis.The rise time (@0 → 100 ppbv) and fall time (@100 → 0 ppbv) were determined to be ~64 s and ~48 s,respectively, at a gas pressure of <100 Torr for the C 2 H 6 sensor operation.

03 NATURAL GAS↗

Absorption spectroscopy based high-speed oxygen concentration measurements at elevated gas temperatures

A sensor built upon tunable diode laser absorption spectroscopy (TDLAS) has been developed for concentration measurements in high-temperature (up to 800 K) gas streams; while the sensor measures gas oxygen and water concentration, temperature and pressure, this work focuses on the challenges and solutions to transient oxygen measurement. A 760-nm diode laser was used to probe a pair of oxygen absorption transitions, and a Herriott cell based multi-pass arrangement was utilized to compensate for the extremely weak oxygen absorption as well as the high gas temperature. This multi-pass arrangement provides a 4297.4-mm absorption path length across a 76.2-mm diameter duct, and an O 2 detection limit ([O 2 ] where SNR=1) of ca. 0.1%. Laboratory validation of the HITRAN spectral parameters of the chosen absorption transitions was performed over a range of high temperatures and oxygen concentrations relevant to engine-exhaust applications. The insensitivity of the Herriott cell arrangement to vibrations and spatial temperature gradients was demonstrated. Conclusions from applications to single- and multi-cylinder engine exhaust are presented and demonstrate the new sensor’s ability to measure fast intra-cycle gas-property transients, and provide insights relevant to advancing internal-combustion-engine technology.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Photonic microresonator based sensor for selective nitrate ion detection

Sensing nitrate concentrations in soil with high sensitivity and selectivity using field-deployable compact sensor platforms is a sought-after goal for environment and agriculture applications. This study demonstrates a new optically based nitrate sensing platform based on ion-selective membrane (ISM) functionalized chip-scale photonic micro-ring resonators. Our approach relies upon measurements of resonance shifts in the micro-resonators and leverages the excellent, though little studied, optical properties of ISMs. Using a high-quality micro-ring resonator, a nitrate ion-selective photonic sensor exhibits a detection limit down to 0.1 parts per million (ppm) and enables nitrate concentration measurements in the 1-100 ppm level, appropriate for soil science and agriculture. Importantly, the sensor also shows high selectivity over other competing anions in soil, such as Cl - and NO 2 - . Here, we argue that this chip-scale approach can be incorporated into compact sensor platforms.

47 OTHER INSTRUMENTATION↗

High-temperature chemical expansion of Pr0.1Ce0.9O2-δ thin films determined by Differential Laser Doppler Vibrometry

The chemical expansion of thin-film praseodymium-cerium oxide solid solutions (Pr 0.1 Ce 0.9 O 2-δ , PCO10) is investigated at temperatures ranging from 500 °C to 800 °C and oxygen activities down to about 10 -22 . Differential Laser Doppler Vibrometry (D-LDV) in combination with periodic electrochemical pumping of oxygen is used to detect very small displacements of the sample surface. With decreasing pumping frequency, the film approaches chemical equilibrium, which is nearly reached at 700 °C below 0.01 Hz. D-LDV enables direct measurement of film thickness changes as well as the bending of the underlying substrates due electrochemically induced lateral mechanical stress. The substrate bending is found to be more than an order of magnitude larger than the film thickness change, increasing the detection limit by the same factor. The thickness change of the thin film is calculated from the measured displacement of the sample surface and compared with directly measured values. Thin-film literature data available for low oxygen activities up to 650 °C agree with our measurements. In addition, the thickness change of the film is determined from the displacement at different sample positions, which validates previous measurements. Finally, thin film chemical expansion is found to be larger by a factor of about 2 than the corresponding bulk value in agreement with predictions from a mechanical model that the out-of-plane expansion of a constrained film is increased.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Polybrominated diphenyl ether levels in foodstuffs collected from three locations from the United States

Objectives: The objectives of this study were to provide updated measurements of PBDEs in US food, to estimate possible difference in levels from differing geographical regions, and to provide an improved estimate of current dietary intake. Methods: Thirty matched food samples for a total of 90 samples were collected from each of three cities (Los Angeles, California; Dallas, Texas; and Albany, New York) and were analyzed for 13 polybrominated diphenyl ether congeners (BDE 28, 47, 49, 66, 85, 99, 100, 138, 153, 154, 183, 203, and 209). Dietary intake of PBDEs was estimated by food type, age, and sex. Results: In this pilot study, we did not note a statistically significant difference in total PBDE levels in food collected from the three locations. The median total PBDE levels (estimating non-detected values as half of the detection limit) in meat, dairy, eggs, and fish were 267 pg/g wet weight (ww) (range 102-3156 pg/g ww), 176 pg/g ww (range 41-954 pg/g ww), 637 pg/g ww (range 193-932 pg/g ww), and 243 pg/g ww (range 36-2161 pg/g ww). PBDE intake from food was estimated to range from 2.7 ng/kg/day for children 2 through 5 years of age to 0.8 ng/kg/day for women aged 60 years and older. This compares closely with our previous study where the intake estimate was 2.7 ng/kg/day for children 2 through 5 years of age and 0.9 ng/kg/day for women aged 60 years and older. Conclusion: We did not find a decrease of PBDEs in food since our previous studies which we expected to find due to the declining use of PBDEs in the USA. These findings could be consistent with food contamination from depot sources of PBDEs. A larger, more representative sampling of the US food supply is indicated based on our findings.

60 APPLIED LIFE SCIENCES↗