Search NASA⌕ Search

SEARCH · Search NASA

Results for “Detector control systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,009 records · Page 56

A system to test the effects of materials on the electron drift lifetime in liquid argon and observations on the effect of water

A materials test system (MTS) has been developed at FNAL to assess the suitability of materials for use in a large liquid argon time projection chamber. During development of the MTS, it was noted that controlling the cryostat pressure with a 'raining' condenser reduced the electron drift lifetime in the liquid argon. The effect of condensing has been investigated using a series of passive materials to filter the condensate. We report the results of these studies and of tests on different candidate materials for detector construction. The inferred reduction of electron drift lifetime by water concentrations in the parts per trillion is of particular interest.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A 15GSa/s, 1.5GHz bandwidth waveform digitizing ASIC

The PSEC4 custom integrated circuit was designed for the recording of fast waveforms for use in large-area time-of-flight detector systems. The ASIC has been fabricated using the IBM-8RF 0.13 micron CMOS process. On each of 6 analog channels, PSEC4 employs a switched capacitor array (SCA) 256 samples deep, a ramp-compare ADC with 10.5 bits of DC dynamic range, and a serial data readout with the capability of region-of-interest windowing to reduce dead time. The sampling rate can be adjusted between 4 and 15 Gigasamples/second [GSa/s] on all channels and is servo-controlled on-chip with a low-jitter delay-locked loop (DLL). The input signals are passively coupled on-chip with a -3 dB analog bandwidth of 1.5 GHz. The power consumption in quiescent sampling mode is less than 50 mW/chip; at a sustained trigger and readout rate of 50 kHz the chip draws 100 mW. After fixed-pattern pedestal subtraction, the uncorrected integral non-linearity is 0.15% over an 750 mV dynamic range. With a linearity correction, a full 1 V signal voltage range is available.The sampling timebase has a fixed-pattern non-linearity with an RMS of 13%, which can be corrected for precision waveform feature extraction and timing.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Pretreated Waste and Melter Feed Composition Variability Testing Using HLW Simulants

This report documents the results of the testing that was performed to fulfill the High Level Waste (HLW) pretreated waste and melter feed product qualification requirements for chemical composition and product loading as described in the Immobilized High Level Waste (IHLW) Wasteform Compliance Plan and the Hanford Tank Waste Treatment and Immobilization Plant (WTP) Contract. Meeting the product quality specifications relies on controlling the melter feed preparation process and the resulting IHLW glass composition. In part, this control depends on the ability of the Melter Feed Preparation Vessel (MFPV) system to homogenize pretreated waste and the melter feed after addition of the glass forming chemicals (GFCs), provide representative sampling of the vessel contents, measure the level over the vessel operating range, and uniformly transfer the vessel contents. A series of tests were conducted on a single scaled down tank, 8 feet in diameter, which was used to represent the WTP HLW MFPV. Prototypic equipment (such as radar level detectors, transfer pumps, agitators, and density probes) was installed in geometrically similar positions to those of the WTP tanks. Other equipment, which is not fully prototypic, was also installed in the tank to fully represent the WTP tank equipment arrangement. In addition, a prototypic autosampler and a hydraulically similar transfer line were installed to represent the WTP tank sampling systems. Testing was performed using simulants that represent the high and low bounds of rheology for the pretreated HLW prior to GFC addition and the HLW melter feed after GFC addition.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Absolute calibration of a hydrogen discharge lamp in the vacuum ultraviolet

A low-pressure hydrogen discharge lamp was calibrated for radiant intensity in the vacuum ultraviolet spectral region on an absolute basis and was employed as a laboratory standard source in spectrograph calibrations. This calibration was accomplished through the use of a standard photodiode detector obtained from the National Bureau of Standards together with onsite measurements of spectral properties of optical components used. The stability of the light source for use in the calibration of vacuum ultraviolet spectrographs and optical systems was investigated and found to be amenable to laboratory applications. The lamp was studied for a range of operating parameters; the results indicate that with appropriate peripheral instrumentation, the light source can be used as a secondary laboratory standard source when operated under preset controlled conditions. Absolute intensity measurements were recorded for the wavelengths 127.7, 158.0, 177.5, and 195.0 nm for a time period of over 1 month, and the measurements were found to be repeatable to within 11 percent.

Nealy, J. E.↗

Portable Fourier Transform Spectroscopy for Analysis of Surface Contamination and Quality Control

Progress has been made into adapting and enhancing a commercially available infrared spectrometer for the development of a handheld device for in-field measurements of the chemical composition of various samples of materials. The intent is to duplicate the functionality of a benchtop Fourier transform infrared spectrometer (FTIR) within the compactness of a handheld instrument with significantly improved spectral responsivity. Existing commercial technology, like the deuterated L-alanine triglycine sulfide detectors (DLATGS), is capable of sensitive in-field chemical analysis. This proposed approach compares several subsystem elements of the FTIR inside of the commercial, non-benchtop system to the commercial benchtop systems. These subsystem elements are the detector, the preamplifier and associated electronics of the detector, the interferometer, associated readout parameters, and cooling. This effort will examine these different detector subsystem elements to look for limitations in each. These limitations will be explored collaboratively with the commercial provider, and will be prioritized to meet the deliverable objectives. The tool design will be that of a handheld gun containing the IR filament source and associated optics. It will operate in a point-and-shoot manner, pointing the source and optics at the sample under test and capturing the reflected response of the material in the same handheld gun. Data will be captured via the gun and ported to a laptop.

Pugel, Diane↗

SuperHERO (Super - High Energy Replicated Optics) Balloon Mission Concept

The SuperHERO hard-x-ray telescope is a proposed high-angular resolution successor to Marshall Space Flight Center’s (MSFC) successful High Energy Replicated Optic (HERO) and the HERO to Explore the Sun (HEROES) balloon missions. By utilizing recent advancements in MSFC’s replicated full shell, NiCo x-ray optic technology, SuperHERO will achieve its technical goal of demonstrating better than 10 arcseconds (arcsecs) angular resolution in half-power diameter (HPD) on a balloon platform. This represents a 6-fold improvement to the current state-of-the-art resolution for hard-x-ray, astrophysical telescopes and will allow for the observation of the high-energy-universe in unprecedented spatial detail. The SuperHERO balloon observatory will consist of seven coaligned, identical telescopes with a total focal length of 12-meters. Each telescope will pair a Mirror Module Assembly (MMA) comprised of NiCo shell optics matched to a CdTe Double-sided Strip Detector (CdTe-DSD) plane provided by iMAGINE-X Inc. and Kavli Institute for the Physics and Mathematics of the Universe (Kavli-IPMU). Iridium coating applied directly to each shell will boost reflectivity into the hard-x-ray regime. Employing additional high-heritage technology, SuperHERO will have an open-truss carbon-composite gondola similarly used on the XL-Calibur balloon mission and will use the Wallops Arc-Second Pointer (WASP) system for attitude control

NickThomas↗

A SiPM-based optical readout system for the EIC dual-radiator RICH

Silicon photomultipliers (SiPM) are candidates selected as the potential photodetector technology for the dual-radiator Ring-Imaging Cherenkov (dRICH) detector at the future Electron-Ion Collider (EIC). SiPM are cheap devices, highly efficient and insensitive to the high magnetic field at the expected location of the sensors in the experiment. Here, on the other hand, SiPM are not radiation tolerant. Despite the integrated radiation level is expected to be moderate it should be tested whether single photon-counting capabilities and the increase in dark count rate can be kept under control to maintain the optimal dRICH detector performance across the years. The current status of the research for the EIC dRICH application and the first results on studies performed on a sample of commercial and prototype SiPM sensors are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-G-TeP3-07: On the Development of Mechano-Biological Assessment of Leukemia Cells Using Optical Tweezers

Purpose: Patients with BCR-ABL (Ph +ve) acute lymphoblastic leukemia are at very high risk of relapse and mortality. In line with the NIH mission to understand the physical and biological processes, we seek to report mechano-biological method to assessment and distinguish treated/untreated leukemia cells. Methods: BCR-ABL leukemia cell populations and silica microspheres were trapped in a 100x magnification optical trapping system (λ=660 nm, 70 mW). Light refracted through the trapped sample was collected in the back focal plane by a quadrant detector to measure the positions of individual cells. The sample was driven at a known frequency and amplitude with a flexure translation stage, and the target’s response was recorded. The measured response was calibrated using the known driving parameters, and information about cell movements due to mechano-biological effects was extracted. Two leukemia cell populations were tested: a control group and a group treated with 2 Gy. Results: The mechano-biological movements of 10 microspheres, control cells, and treated cells were tracked over a ∼30 minute window at 1 minute intervals. The microsphere population did not see significant change in mechano-biological movements over the testing interval and remained constant. The control cell population saw a two-fold rise in activity that peaked around 1200 seconds, then dropped off sharply. The treated cell population saw a two-fold rise in activity that peaked at 400 seconds, and dropped off slowly. Conclusion: The investigated technique allows for direct measurement the movements of a trapped object due to mechano-biological effects such as thermal and extracellular motion. When testing microspheres, the mechano-biological activity remained constant over time due to the lack of biological factors. In both the control and treated cell populations, the mechano-biological activity was increased, possibly due to mitochondrial activation. This extra activity decreased over time, possibly due to cellular damage from trapping radiation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SEXTANT X-Ray Pulsar Navigation Demonstration: Flight System and Test Results

The Station Explorer for X-ray Timing and Navigation Technology (SEXTANT) is a technology demonstration enhancement to the Neutron-star Interior Composition Explorer (NICER) mission. NICER is a NASA Explorer Mission of Opportunity that will be hosted on the International Space Station (ISS). SEXTANT will, for the first time, demonstrate real-time, on-board X-ray Pulsar Navigation (XNAV), a significant milestone in the quest to establish a GPS-like navigation capability available throughout our Solar System and beyond. This paper gives an overview of the SEXTANT system architecture and describes progress prior to environmental testing of the NICER flight instrument. It provides descriptions and development status of the SEXTANT flight software and ground system, as well as detailed description and results from the flight software functional and performance testing within the highfidelity Goddard Space Flight Center (GSFC) X-ray Navigation Laboratory Testbed (GXLT) software and hardware simulation environment. Hardware-in-the-loop simulation results are presented, using the engineering model of the NICER timing electronics and the GXLT pulsar simulator-the GXLT precisely controls NASA GSFC's unique Modulated X-ray Source to produce X-rays that make the NICER detector electronics appear as if they were aboard the ISS viewing a sequence of millisecond pulsars.

SEXTANT↗

Preliminary design of a helium cryogenic system for SAND detector at LBNF-DUNE near site

The Long-Baseline Neutrino Facility (LBNF) is providing a helium cryogenic system to support the superconducting solenoid magnet of the System for on-Axis Neutrino Detection (SAND) for the Deep Underground Neutrino Experiment (DUNE) Near Site at Fermilab in Batavia, IL. The design started in 2020 and construction is set to begin in the mid 2020‘s.The helium cryogenic system primarily consists of a helium refrigerator system, distribution valve boxes, vacuum-jacketed helium and nitrogen transfer lines, warm gaseous helium transfer system, instruments and control system, and gaseous helium storage tanks. It is designed to provide supercritical helium at around 3 bara and 5 K with expansion from 3 to 1.2 bara in the SAND cryostat and 70K forced cold gas helium to cool the thermal shields of the SAND cryostat. The SAND superconductive magnet is indirectly cooled through a liquid helium thermosiphon cycle. A pair of 3 kA leads is cooled by the gas helium vaporized from the liquid helium reservoir in the cryostat turret. The helium system will share the liquid nitrogen tank and liquid nitrogen phase separator with the Near Site Liquid Argon system. The helium recycle compressor system, GHe tanks and LN2 tank will be located on the Surface. The cryogenic facilities including refrigerator cold box, valve boxes and LN2 phase separator will be located on the shaft cryo-mezzanine in the underground cavern. The shaft connecting surface and cavern is more than 60 meter deep. The helium vacuum-jacketed transfer line between the cold box and the SAND magnet is more than 50 meter long. This paper presents the preliminary design of the helium cryogenic system including the design scheme, process flow diagram, heat load estimates, layout plan and so on.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Phase-change Reconfigurable Optical WavEfront Synthesis System (PROWESS)

We report the design, fabrication, and testing of electrically tunable metasurface k-space filters based on the low-loss, high-contrast phase-change material GSST and a transparent Si electrode heating architecture. A 10x10 array of PCM elements integrated with Si heaters was fabricated via foundry processes, and used to actively control the crystallinity of a metasurface consisting of GSST nano antennae. By selectively varying the structural state of individual PCM elements, specific k-vectors of transmitted light can effectively be filtered out, resulting in improved imaging quality by reducing the scattered light that reaches a detector. Optimized doping profiles in the Si heaters allow for uniform, low power, reliable and repeatable switching of the GSST state. Compared to other k-space filters, this new architecture is completely transparent to the wavelength of interest and can be actively reconfigured in real time with high performance, low power consumption and a small footprint. The 10x10 array device is a proof-of-concept demonstration that can enable high-resolution arbitrary wavefront synthesis and correction in the future, with key applications in optical communications, beam steering, remote sensing, and adaptive optics.

phase change material↗

An adiabatic demagnetization refrigerator for SIRTF

An adiabatic demagnetization refrigerator (ADR) has been proposed to cool bolometric infrared detectors on the multiband imaging photometer of the Space Infrared Telescope Facility (SIRTF). One such refrigerator has been built which uses a ferric ammonium alum salt pill suspended by nylon threads in a 3-T solenoid. The resonant modes of this suspension are above 100 Hz. The heat leak to the salt pill is less than 0.5 microW. The system has a hold time at 0.1K of more than 12 h. The cold stage temperature is regulated with a feedback loop that controls the magnetic field. A second, similar refrigerator is being built at a SIRTF prototype to fly on a ballon-borne telescope. It will use a ferromagnetic shield. The possibility of using a high-Tc solenoid-actuated heat switch is also discussed.

Timbie, P. T.↗

SPARCLE: Validation of Observing System Simulations (SPace Readiness Coherent Lidar Experiment)

NASA recently approved a mission to fly a Doppler Wind Lidar (DWL) on a U.S. Space Shuttle. SPARCLE, managed by Marshall Space Flight Center in Huntsville, AL, is targeted for launch in March 2001. This mission is viewed as a necessary demonstration of a solid state (2 micron) lidar using coherent detection before committing resources to a 3-5 year research or operational mission. While, to many, this shuttle mission is seen as the first step in a series leading to a fully operational wind observing system, to others, it is a chance to validate predictions of performance based upon theoretical models, analyses of airborne and ground-based data, and sophisticated observing system simulation experiments. This paper will be presented in two parts: first a brief overview of the SPARCLE mission and second, a summary of current performance predictions and key contributions from ground- based and airborne DWL research. The SPARCLE instrument is a 100 mJ, 6 Hz, diode-pumped 2-micron laser with a .25 m telescope using heterodyne mixing in a fiber and an InGaAs detector. A 25 cm silicon wedge scanner will be used in step-stare modes with dwells ranging from 60 seconds to .5 seconds. Pointing knowledge is achieved with a dedicated GPS/INS mounted close to the lidar. NASA's Hitchhiker program is providing the instrument enclosures (2 cans) and mission logistics support. An on-board data system is sized to record 150 Gbytes of raw signal from a two 400 MHZ A/D converters. On-board signal processing will be used to control the frequency of the Local Oscillator. SPARCLE is predicted to have a single shot backscatter sensitivity near 1x10(exp -6) m-1 sr-1, To achieve higher sensitivity, shot accumulation will be employed. Ground-based, 2 micron DWLs have been used to assess the benefits of shot accumulation (approximately SQRT for SNR). Airborne programs like MACAWS have provided good datasets for evaluating various sampling strategies and signal processing algorithms. Using these real data to calibrate our simulation models, we can describe when and how well SPARCLE is expected to preform. Outputs from these performance models will be presented.

Emmitt, G. D.↗

Alignment-Insensitive Lower-Cost Telescope Architecture

This architecture features an active wavefront sensing and control scheme along with methods for measuring the relative positions of the primary to aft optics, such as the secondary mirror, and should enable larger and cheaper telescope architectures needed for future applications. A wavefront source/sensor is placed at the center of curvature of the primary mirror. The system provides continuous light onto a primary mirror that is retro-reflected onto itself. This allows the wavefront controller to constantly update the positions of the primary mirror segments (or deformable mirror actuators). Another function of this innovation involves using a concave mirror on the back of the secondary mirror (or other aft optic) that has the same center-of-curvature location (in defocus) as the primary mirror. The two return beams can be aligned next to each other on a detector, or radially on top of each other. This provides a means with which to measure the relative position of the primary to the secondary (or other aft optics), thus allowing for the removal of misalignment of the center-of-curvature source/sensor (meaning it doesn't need precision placement) and also provides a means with which to monitor the relative alignment over time. This innovation does not require extremely good thermal stability on the primary mirror and can thus be used in any thermal environment and with cheaper materials. In addition to this, the architecture lets one phase (or align) the primary mirror independent of whether a star or scene is in the field. The segmented, spherical primary allows for cost-effective three-meter class (e.g. Midex and Discovery) missions as well as enabling 30-meter telescope solutions that can be manufactured in a reasonable amount of time. The continuous wavefront sensing and control architecture enables missions for low-Earth-orbit.

Feinberg, Lee↗

Multi-Channel Integrated Circuits For Use In Research With Radioactive Ion Beams

The Integrated Circuits Design Research Laboratory at Southern Illinois University Edwardsville (SIUE) has been collaborating over the past several years with the Nuclear Reactions Group at Washington University (WU) on the development of a family of custom, multi-channel Integrated Circuits (ICs). To date, the collaboration has successfully produced two micro-chips. The first was an analog shaped and peak sensing chip known as HINP16C (Heavy Ion Nuclear Physics--16 Channel). The second chip, christened PSD8C (Pulse Shape Discrimination--8 Channel), was designed to logically complement (in terms of detector types) the HINP16C chip. The HINP16C chip, for use with solid-state detectors, produces sparsified analog pulse trains for both linear (pulse height) and timing (relative to an external reference) signals. A shaper and peak detector are implemented in the linear branch, and a pseudo Constant-Fraction Discriminator (CFD) and Time-to-Voltage Converter (TVC) are implemented in the logic/timing branch. The internal and external gain options make the chip suitable for use in a wide variety of applications. PSD8C greatly simplifies the pulse-processing electronics needed for large arrays of scintillation detectors. As the PSD8C employs user-controlled, multi-region charge integration, particle identification is inherent in the design. Each of the three pulse-height sub-channels consists of a gated integrator with eight programmable charging rates and an externally programmable gate generator that defines the start (with 4 time ranges) and the width (with 4 time ranges) of the gate, relative to an external discriminator signal. Moreover, each channel on the chip also contains a TVC. This paper describes the design, capabilities, and features of the HINP16C and PSD8C ICs along with a description of how the chips are being used. It also discusses modifications and enhancements which have been made to both chips and their associated prototypical systems in order to improve ease of use and increase performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SCALA: In situ calibration for integral field spectrographs

The scientific yield of current and future optical surveys is increasingly limited by systematic uncertainties in the flux calibration. This is the case for type Ia supernova (SN Ia) cosmology programs, where an improved calibration directly translates into improved cosmological constraints. Current methodology rests on models of stars. Here we aim to obtain flux calibration that is traceable to state-of-the-art detector-based calibration. Methods. We present the SNIFS Calibration Apparatus (SCALA), a color (relative) flux calibration system developed for the SuperNova integral field spectrograph (SNIFS), operating at the University of Hawaii 2.2 m (UH 88) telescope. Results. By comparing the color trend of the illumination generated by SCALA during two commissioning runs, and to previous laboratory measurements, we show that we can determine the light emitted by SCALA with a long-term repeatability better than 1%. We describe the calibration procedure necessary to control for system aging. We present measurements of the SNIFS throughput as estimated by SCALA observations. Conclusions. The SCALA calibration unit is now fully deployed at the UH 88 telescope, and with it color-calibration between 4000 Å and 9000 Å is stable at the percent level over a one-year baseline.

79 ASTRONOMY AND ASTROPHYSICS↗

Heralding efficiency and correlated-mode coupling of near-IR fiber-coupled photon pairs

We report on a systematic experimental study of heralding efficiency and generation rate of telecom-band infrared photon pairs generated by spontaneous parametric down-conversion and coupled to single mode optical fibers. We define the correlated-mode coupling efficiency--an inherent source efficiency--and explain its relation to heralding efficiency. For our experiment, we developed a reconfigurable computer controlled pump-beam and collection-mode optical apparatus which we used to measure the generation rate and correlated-mode coupling efficiency. The use of low-noise, high-efficiency superconducting-nanowire single-photon-detectors in this setup allowed us to explore focus configurations with low overall photon flux. The measured data agree well with theory and we demonstrated a correlated-mode coupling efficiency of 97%±2%, which is the highest efficiency yet achieved for this type of system. These results confirm theoretical treatments and demonstrate that very high overall heralding efficiencies can, in principle, be achieved in quantum optical systems. We expect that these results and techniques will be widely incorporated into future systems that require, or benefit from, a high heralding efficiency.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

NASA Tech Briefs, February 2007

Topics covered include: Calibration Test Set for a Phase-Comparison Digital Tracker; Wireless Acoustic Measurement System; Spiral Orbit Tribometer; Arrays of Miniature Microphones for Aeroacoustic Testing; Predicting Rocket or Jet Noise in Real Time; Computational Workbench for Multibody Dynamics; High-Power, High-Efficiency Ka-Band Space Traveling-Wave Tube; Gratings and Random Reflectors for Near-Infrared PIN Diodes; Optically Transparent Split-Ring Antennas for 1 to 10 GHz; Ice-Penetrating Robot for Scientific Exploration; Power-Amplifier Module for 145 to 165 GHz; Aerial Videography From Locally Launched Rockets; SiC Multi-Chip Power Modules as Power-System Building Blocks; Automated Design of Restraint Layer of an Inflatable Vessel; TMS for Instantiating a Knowledge Base With Incomplete Data; Simulating Flights of Future Launch Vehicles and Spacecraft; Control Code for Bearingless Switched- Reluctance Motor; Machine Aided Indexing and the NASA Thesaurus; Arbitrating Control of Control and Display Units; Web-Based Software for Managing Research; Driver Code for Adaptive Optics; Ceramic Paste for Patching High-Temperature Insulation; Fabrication of Polyimide-Matrix/Carbon and Boron-Fiber Tape; Protective Skins for Aerogel Monoliths; Code Assesses Risks Posed by Meteoroids and Orbital Debris; Asymmetric Bulkheads for Cylindrical Pressure Vessels; Self-Regulating Water-Separator System for Fuel Cells; Self-Advancing Step-Tap Drills; Array of Bolometers for Submillimeter- Wavelength Operation; Delta-Doped CCDs as Detector Arrays in Mass Spectrometers; Arrays of Bundles of Carbon Nanotubes as Field Emitters; Staggering Inflation To Stabilize Attitude of a Solar Sail; and Bare Conductive Tether for Decelerating a Spacecraft.

Source record↗