Search NASA⌕ Search

SEARCH · Search NASA

Results for “Dose Characterization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,009 records · Page 56

Characterization of a gigabit transceiver for the ATLAS inner tracker pixel detector readout upgrade

We present a gigabit transceiver prototype Application Specific Integrated Circuit (ASIC), GBCR, for the ATLAS Inner Tracker (ITk) Pixel detector readout upgrade. GBCR is designed in a 65-nm CMOS technology and consists of four upstream receiver channels, a downstream transmitter channel, and an Inter-Integrated Circuit (I2C) slave. The upstream channels receive the data at 5.12 Gbps passing through 5-meter 34-American Wire Gauge (AWG) Twin-axial (Twinax) cables, equalize and retime them with a recovered clock, and then drive an optical transmitter. The downstream channel receives the data at 2.56 Gbps from an optical receiver and drives the cable as same as the upstream channels. The jitter of the upstream channel output is measured to be 35 ps (peak-peak) when the Clock-Data Recovery (CDR) module is turned on and the jitter of the downstream channel output after the cable is 138 ps (peak-peak). The power consumption of each upstream channel is 72 mW when the CDR module is turned on and the downstream channel consumes 27 mW. GBCR survives the total ionizing dose of 200 kGy.

47 OTHER INSTRUMENTATION↗

Primary radiation damage in bone evolves via collagen destruction by photoelectrons and secondary emission self-absorption

X-rays are invaluable for imaging and sterilization of bones, yet the resulting ionization and primary radiation damage mechanisms are poorly understood. Here we monitor in-situ collagen backbone degradation in dry bones using second-harmonic-generation and X-ray diffraction. Collagen breaks down by cascades of photon-electron excitations, enhanced by the presence of mineral nanoparticles. We observe protein disintegration with increasing exposure, detected as residual strain relaxation in pre-stressed apatite nanocrystals. Damage rapidly grows from the onset of irradiation, suggesting that there is no minimal ‘safe’ dose that bone collagen can sustain. Ionization of calcium and phosphorous in the nanocrystals yields fluorescence and high energy electrons giving rise to structural damage that spreads beyond regions directly illuminated by the incident radiation. Our findings highlight photoelectrons as major agents of damage to bone collagen with implications to all situations where bones are irradiated by hard X-rays and in particular for small-beam mineralized collagen fiber investigations.

36 MATERIALS SCIENCE↗

Microstructural evolution and precipitation in γ-LiAlO 2 during ion irradiation

Polycrystalline γ-LiAlO 2 pellets were sequentially irradiated with 120 keV He + and 80 keV D 2 + ions to the fluences of 1 × 10 17 and 2 × 10 17 (He + + D + )/cm 2 at 573 K. Additional irradiation was performed to a fluence of 2 × 10 17 (He + + D + )/cm 2 at 773 K. The irradiated pellets were characterized using scanning transmission electron microscopy, time-of-flight secondary ion mass spectrometry, and grazing incidence x-ray diffraction. Lattice damage, amorphization, and fractures are observed with no evidence for the formation of secondary-phase precipitates in the pellets irradiated up to an ion fluence of 2 × 10 17 (He + + D + )/cm 2 at 573 K. In contrast, faceted precipitates with sizes larger than 100 nm formed in a pellet irradiated to 2 × 10 17 (He + + D + )/cm 2 at 773 K. Analyses of the diffraction and composition data suggest that the precipitates have a spinel-type structure, likely a non-stoichiometric LiAl 5 O 8 with Li depletion. This could be an intermediate phase with Li atoms at the octahedral and possibly tetrahedral sites as well. It is speculated that as the dose increases, Li loss will continue and the precipitates will approach a composition of alumina primarily in phases of α-Al 2 O 3 and amorphized Al 2 O 3 .

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

A Novel Dosimetry Method for Small Animal Irradiators Using 3D-printed Mouse Phantoms and Alanine Dosimeters

Abstract Accurate dosimetry is a crucial component of small animal and preclinical irradiation studies. Various dosimetry options are available but fail to characterize complex geometries and variable energy spectra of modern x-ray irradiators accurately. These options also lack national/international standards of recognition. This paper presents a novel dosimetry system, Dosequate, which uses murine phantoms embedded with alanine dosimeters and paired with x-ray energy spectra corrections to deliver consistent and accurate dosimetry measurements. This study compares Dosequate measurements against a Precision X-RAD 320 internal ion chamber and the treatment planning system of an Xstrahl Small Animal Radiation Research Platform. Results demonstrate the accuracy and reproducibility of the Dosequate system, highlighting its potential for standardizing dosimetry in preclinical research throughout the industry. Results demonstrate the accuracy and reproducibility of the Dosequate system, highlighting its potential for standardizing dosimetry in preclinical research throughout the industry. The Dosequate dosimetry method provides a robust and standardized approach for measuring absorbed dose in small animal irradiators. Its accuracy, reproducibility, and ability to account for complex irradiation geometries make it a valuable tool for preclinical research. This system has the potential to significantly improve the intercomparability of studies across different facilities and enhance the reliability of results.

Environmental Sciences & Ecology↗

Electromagnetic guided couch and multileaf collimator tracking on a TrueBeam accelerator

Purpose: Couch and MLC tracking are two promising methods for real-time motion compensation during radiation therapy. So far, couch and MLC tracking experiments have mainly been performed by different research groups, and no direct comparison of couch and MLC tracking of volumetric modulated arc therapy (VMAT) plans has been published. The Varian TrueBeam 2.0 accelerator includes a prototype tracking system with selectable couch or MLC compensation. This study provides a direct comparison of the two tracking types with an otherwise identical setup. Methods: Several experiments were performed to characterize the geometric and dosimetric performance of electromagnetic guided couch and MLC tracking on a TrueBeam accelerator equipped with a Millennium MLC. The tracking system latency was determined without motion prediction as the time lag between sinusoidal target motion and the compensating motion of the couch or MLC as recorded by continuous MV portal imaging. The geometric and dosimetric tracking accuracies were measured in tracking experiments with motion phantoms that reproduced four prostate and four lung tumor trajectories. The geometric tracking error in beam’s eye view was determined as the distance between an embedded gold marker and a circular MLC aperture in continuous MV images. The dosimetric tracking error was quantified as the measured 2%/2 mm gamma failure rate of a low and a high modulation VMAT plan delivered with the eight motion trajectories using a static dose distribution as reference. Results: The MLC tracking latency was approximately 146 ms for all sinusoidal period lengths while the couch tracking latency increased from 187 to 246 ms with decreasing period length due to limitations in the couch acceleration. The mean root-mean-square geometric error was 0.80 mm (couch tracking), 0.52 mm (MLC tracking), and 2.75 mm (no tracking) parallel to the MLC leaves and 0.66 mm (couch), 1.14 mm (MLC), and 2.41 mm (no tracking) perpendicular to the leaves. The motion-induced gamma failure rate was in mean 0.1% (couch tracking), 8.1% (MLC tracking), and 30.4% (no tracking) for prostate motion and 2.9% (couch), 2.4% (MLC), and 41.2% (no tracking) for lung tumor motion. The residual tracking errors were mainly caused by inadequate adaptation to fast lung tumor motion for couch tracking and to prostate motion perpendicular to the MLC leaves for MLC tracking. Conclusions: Couch and MLC tracking markedly improved the geometric and dosimetric accuracies of VMAT delivery. However, the two tracking types have different strengths and weaknesses. While couch tracking can correct perfectly for slowly moving targets such as the prostate, MLC tracking may have considerably larger dose errors for persistent target shift perpendicular to the MLC leaves. Advantages of MLC tracking include faster dynamics with better adaptation to fast moving targets, the avoidance of moving the patient, and the potential to track target rotations and deformations.

60 APPLIED LIFE SCIENCES↗

Status Update on IAEA MODARIA II Working Group 1 (Assessment and Decision Making) - 19391

During WM2018, the work being done under the International Atomic Energy Agency (IAEA)'s Modelling and Data for Radiological Impact Assessments (MODARIA) II Programme (https://wwwns.iaea.org/projects/modaria/modaria2.asp?s=8 and l=129) was introduced. The Programme comprises seven working groups covering a wide range of topics. Amongst them, Working Group 1 (WG1) is focused on dose assessment and decision aiding tools to address existing exposure situations due to past practices involving naturally occurring radioactive material (NORM) and nuclear legacy sites. Specifically, this covers the development of methods and toolsets for risk-informed decision-making for such complex sites, and includes practical demonstration of decision-making processes and tools through case studies. During 2018 WG1 participants met twice to discuss the status and plans of work being conducted by the WG. The group held its Second Interim Meeting from 7 to 11 May 2018 at the Jozef Stefan Institute (JSI) in Ljubljana, Slovenia. The objectives of the meeting were to: (1) Discuss the status of WG1 work; (2) Start preparation of the interim draft version of the MODARIA II WG1 Report (herein referred to as the 'Interim Report'); (3) Review the progress of planned data analyses, model-model comparisons, and model-data comparisons being conducted through case studies for the Tessenderlo Chemie Site in Belgium, the Zapadnoe Uranium Mill Tailings Site in Ukraine, and a Former Tin Processing Facility Site in Brazil; (4) Discuss calculations conducted for a NORM Site in China for potential addition to the WG1 case studies; (5) Report on progress on topical studies and other assignments performed to support the preparation of several sections of the Interim Report; and (6) Discuss plans for incorporating some preliminary case studies considered by MODARIA I WG1 and MODARIA I WG3. During the meeting in Slovenia, WG1 participants also visited the Zirovski vrh (RZV) Uranium Mine and Mill Tailings Site near Ljubljana. From 22 to 25 October 2018, WG1 members also participated in the MODARIA II Third Technical Meeting in Vienna, Austria. The meeting facilitated analysis of the progress made so far by the seven working groups, as well as exploration of the dissemination of the results of the MODARIA II Programme through publication in scientific journals dealing with the various subject areas covered by the Programme. WG1 participants focused on the preparation of its Interim Report, and engaged in technical exchanges with the IAEA Le Trench Project on characterization, assessment, remediation and management of buried waste at legacy trench sites, as well as the To Enhance uncertainties Reduction and stakeholders Involvement Towards integrated and graded Risk management of humans and wildlife In long-lasting radiological Exposure Situations (TERRITORIES) project (https://territories.eu/). Currently, WG1 is in the process of preparing a draft report to document the results of its various case studies and special topics, and is preparing for the final Interim Meeting in May 2019 and the final Technical Meeting in October 2019, before the conclusion of the MODARIA II Program at the end of 2019. This paper will provide a status update of these activities, along with preliminary information on the WG1 report, including potential recommendations for future activities. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

SU-F-E-17: A Dedicated Teaching and Research Linac as a Stepping Stone to Introduce Medical Physics to Students

Purpose: This work describes how a non-clinical, research and teaching Linac is used as an extremely motivating and exciting way to introduce students to medical physics. Methods: The dedicated facility was inaugurated in 2014. The facility is composed of a fully equipped and functional state-of-the-art Varian TrueBeam Linac and a complete set of physics instruments and QA phantoms for the Linac and onboard imaging. The Linac bunker and treatment console are oversized such that a class of 12–15 can comfortably fit, seated if needed for longer sessions. A 3cr undergraduate laboratory course that includes medical imaging, x-ray source characterization (mAs, kVp, and filtering) and many others including an introductory Linac laboratory was created. The latter is composed of one general 4-hours session and a weekly 4-hours session for teams of two students. The general session includes a hands-on presentation of the Linac, its environment and a formal safety and radiation protection course (with an exam). Results: Since the winter of 2015, senior undergraduate (total of 15) pursuing either the medical physics or the biomedical engineering tracks can register. At the Linac, the students are allowed full control of the experiments, including set-up and irradiation. Supervisor intervention is limited to safety concerns for students or equipment. Measurements of output factors using two chambers (regular and small field) for various field sizes (1×1 to 30×30 cm{sup 2}) and of detailed depth-dose curves for 6 MV, 6 and 12 MeV beams are to be performed and discussed in a formal report. Conclusion: Full access to, and control of, a Linac is the high point of this course. It provides a glimpse of medical physics and generates an experimental background for those continuing to CAMPEP programs. This dedicated, non-clinical facility further enable enhance CAMPEP graduate teaching and research activities not possible with a clinical device.

60 APPLIED LIFE SCIENCES↗

The effects of space radiation on thin films of YBa2Cu3O(7-x)

This investigation had two objectives: (1) to determine the effects of space radiation on superconductor parameters that are most important in space applications; and (2) to determine whether this effect can be simulated with Co-60 gamma rays, the standard test method for space materials. Thin films of yttrium barium copper oxide (YBCO) were formed by coevaporation of Y, BaF2, and Cu and post-annealing in wet oxygen at 850 C for 3.5 h. The substrate used was (100) silicon with an evaporated zirconia buffer layer. The samples were characterized by four point probe electrical measurements as a function of temperature. The parameters measured were the zero resistance transition temperature T(sub c) and the room temperature resistance. The samples were then exposed to Co-60 gamma-rays in air and in pure nitrogen, and to 780 keV electrons, in air. The parameters were then remeasured. The results are summarized. The results indicate little or no degradation in the parameters measured for samples exposed up to 10 Mrads of gamma-rays in nitrogen. However, complete degradation is preliminarily attributed to the high level of ozone generated in the chamber by the gamma-ray interaction with air. It can be concluded that: (1) the electron component of space radiation does not degrade the critical temperature of the YBCO films described, at least for energies around 800 keV and doses similar to those received by surface materials on spacecraft in typical remote sensing missions; and (2) for qualifying this and other superconducting materials against the space-radiation threat the standard test method used in the aerospace industry, namely, exposure to Co-60 gamma-rays in air, may require some further investigation. As a minimum, the sample must be either in vacuum or in positive nitrogen pressure.

Herschitz, R.↗

Responses of Microbes to Modeled Space Radiation

The built environment of spaceships is host to a microbial community that affects crew and craft alike. While the static composition of this community has been characterized and its temporal dynamics examined, the mechanisms controlling its make-up and evolutionary trajectory are not understood. Systematic analyses of microbial diversity show consistent patterns in community composition and function. Understanding these patterns' ecological origins remains a significant challenge, as it requires connecting processes at varying temporal and spatial scales. However, it is clear that the state and trajectories of microbial communities are in-part determined by their physical environment. In this regard, the spaceflight environment includes numerous interacting factors that differentiate it from Earth environments, including an altered atmospheric composition, reduced gravity (and thus altered fluid dynamics), and increased ionizing radiation. These factors impart selective pressures on microbial communities that affect their evolutionary trajectories and thus the risks and benefits these communities represent to crew and craft. The radiation environment of space leads to chronic exposure to low doses and is difficult to mimic on Earth. Thus, little is known about how microbial communities in spacecraft will respond and evolve. Therefore, given the limitations of existing studies, we aim to empirically determine how exposure to low doses of ionizing radiation for thousands of cell divisions affects rates of mutation accumulation in bacteria and the trajectory of their evolution. In this way, we will provide a critical set of data for designing safe and robust space missions. Here we discuss our progress towards this aim, including the construction of exposure facilities, our culturing and analysis approach, and preliminary data.

radiation↗

Evidence for factors modulating radiation-induced G2-delay: potential application as radioprotectors

Manipulation of checkpoint response to DNA damage can be developed as a means for protecting astronauts from the adverse effects of unexpected, or background exposures to ionizing radiation. To achieve this goal reagents need to be developed that protect cells from radiation injury by prolonging checkpoint response, thus promoting repair. We present evidence for a low molecular weight substance excreted by cells that dramatically increases the duration of the G2-delay. This compound is termed G2-Arrest Modulating Activity (GAMA). A rat cell line (A1-5) generated by transforming rat embryo fibroblasts with a temperature sensitive form of p53 plus H-ras demonstrates a dramatic increase in radiation resistance after exposure to low LET radiation that is not associated with an increase in the efficiency of rejoining of DNA double strand breaks. Radioresistance in this cell line correlates with a dramatic increase in the duration of the G2 arrest that is modulated by a GAMA produced by actively growing cells. The properties of GAMA suggest that it is a low molecular weight heat-stable peptide. Further characterization of this substance and elucidation of its mechanism of action may allow the development of a biological response modifier with potential applications as a radioprotector. GAMA may be useful for protecting astronauts from radiation injury as preliminary evidence suggests that it is able to modulate the response of cells exposed to heavy ion radiation, similar to that encountered in outer space.

NASA Discipline Radiation Health↗

Hanford Site Composite Analysis Special Analysis: Inventory and Solid Waste Release Modeling for the LLBG Sensitivity Case - UCAQ-22-01 Inventory Discrepancies for 218-E-12B, 218-W-3A, and 218-W-3AE in the Hanford Site Composite Analysis

This environmental calculation file (ECF) documents the methodologies, assumptions, and results of four sensitivity analyses that reevaluate the representativeness of solid-waste radionuclide inventory and release rate from three solid waste sites included in the recently completed Hanford Site Composite Analysis (CA) (DOE-RL-2019-52, Composite Analysis for Low-Level Waste Disposal in the Hanford Site Central Plateau (FY 2020), Rev. 1) (hereinafter called the CA Update). Specifically, this ECF reevaluates the representativeness of the base case inventory and radionuclide waste release rates from three solid waste sites (i.e., 218-E-12B, 218-W-3A, and 218-W-3AE) and two radionuclides (i.e., carbon-14 [C-14] and technetium-99 [Tc-99]). These three waste sites and two radionuclides were identified as being the most significant contributors to groundwater contamination and dose in the CA Update for the Inner Area boundary at times periods after the compliance period. This ECF first evaluates the representativeness of the C-14 and Tc-99 inventory and second, radionuclide release rates for the three waste sites1. If the inventory and release rates assumed in the CA Update are determined to be not representative, as hypothesized in the CA Update, then this ECF evaluates the impact of more representative inventories and release rates on the transfer of radionuclides to the vadose zone. The four analyses described in this ECF are as follows: 1) 218-E-12B C-14 Inventory and Release Rate Sensitivity Case – Determine the representativeness of the C-14 inventory and associated waste release rate from the 218-E-12B waste site assumed in the CA Update. If the inventory and associated waste release are more appropriately characterized as being different from the assumptions in the CA Update, then update the predicted C-14 release rate and compare the results to the results presented in the CA Update (DOE/RL-2019-52); 2) 218-W-3A C-14 Inventory and Release Rate Sensitivity Case – Determine the representativeness of the C-14 inventory and associated waste release rate from the 218-W-3A waste site assumed in the CA Update. If the inventory and associated waste release are more appropriately characterized as being different from the assumptions in the CA Update, then update the predicted C-14 release rate and compare the results to the results presented in the CA Update (DOE/RL-2019-52); 3) 218-W-3AE Tc-99 Release Rate Sensitivity Case – Determine the representativeness of the Tc-99 inventory and associated waste release rate from the 218-W-3AE waste site assumed in the CA Update. If the inventory and associated waste release are more appropriately characterized as being different from the assumptions in the CA Update, then update the predicted Tc-99 release rate and compare the results to the results presented in the CA Update (DOE/RL-2019-52); 4) 218-W-3AE Tc-99 Release Footprint Sensitivity Case – Determine the representativeness of the Tc-99 waste area footprint for the 218-W-3AE waste site assumed in the CA Update. If the footprint of the waste is more appropriately characterized as being different from the assumptions in the CA Update, then update the predicted Tc-99 release rate and compare the results to the result presented in the CA Update (DOE/RL-2019-52).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The Assessment and Validation of Mini-Compact Tension Test Specimen Geometry and Progress in Establishing Technique for Fracture Toughness Master Curves for Reactor Pressure Vessel Steels

Small specimens are playing the key role in evaluating properties of irradiated materials. The use of small specimens provides several advantages. Typically, only a small volume of material can be irradiated in a reactor at desirable conditions in terms of temperature, neutron flux, and neutron dose. A small volume of irradiated material may also allow for easier handling of specimens. Smaller specimens reduce the amount of radioactive material, minimizing personnel exposures and waste disposal. However, use of small specimens imposes a variety of challenges as well. These challenges are associated with proper accounting for size effects and transferability of small specimen data to the real structures of interest. Any fracture toughness specimen that can be made out of the broken halves of standard Charpy specimens may have exceptional utility for evaluation of reactor pressure vessels (RPVs) since it would allow one to determine and monitor directly actual fracture toughness instead of requiring indirect predictions using correlations established with impact data. The Charpy V-notch specimen is the most commonly used specimen geometry in surveillance programs. Assessment and validation of mini-CT specimen geometry has been performed on previously well characterized HSST Plate 13B, an A533B class 1 steel. It was shown that the fracture toughness transition temperature measured by these Mini-CT specimens is within the range of To values that were derived from various large fracture toughness specimens. Moreover, the scatter of the fracture toughness values measured by Mini-CT specimens perfectly follows the Weibull distribution function providing additional proof for validation of this geometry for the Master Curve evaluation of rector pressure vessel steels. Moreover, the International collaborative program has been developed to extend the assessment and validation efforts to irradiated weld metal. The program is underway and involves ORNL, CRIEPI, and EPRI.

36 MATERIALS SCIENCE↗

Characterization of CST Post-Processing AP-105 Hanford Tank Waste

The primary goal of the Tank Side Cesium Removal (TSCR) system, under development by Washington River Protection Solutions, LLC (WRPS), is to remove entrained solids and 137 Cs from the Hanford tank waste supernate to expedite production of low-activity waste. Ion exchange (IX) testing of 10.9 L of waste from Hanford tank 241-AP-105 (AP-105), performed by Pacific Northwest National Laboratory, used a lead-lag-polish column format, with a bed volume of 10 mL per column, to decontaminate tank waste supernate using crystalline silicotitanate (CST) as the IX media. The AP-105 Cs IX processing test, discussed elsewhere, resulted in a shorter transition zone (i.e., steeper load curve) than those defined by wastes from tanks 241-AP-107 and 241-AW-102.1 The shorter transition zone was indicative of a matrix effect retarding Cs capacity. Therefore, aliquots of spent CST from the lead, lag, and polish columns were subjected to a digestion protocol to quantify analytes retained by the CST and extrapolate the impact on Cs capacity. The spent CST was digested using a combination of 5 M HNO 3 and H 2 O 2 with vigorous heating and stirring. Due to the radiation dose accompanying the 137 Cs on the CST columns, a secondary Cs separation by ammonium molybdophosphate embedded in polyacrylonitrile (AMP-PAN) was performed to separate the 137 Cs from the CST so the samples could be contact-handled for analysis outside of a shielded facility.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Development of Mini-Compact Tension Test Method for Determining Fracture Toughness Master Curves for Reactor Pressure Vessel Steels

Small specimens are playing the key role in evaluating properties of irradiated materials. The use of small specimens provides several advantages. Typically, only a small volume of material can be irradiated in a reactor at desirable conditions in terms of temperature, neutron flux, and neutron dose. A small volume of irradiated material may also allow for easier handling of specimens. Smaller specimens reduce the amount of radioactive material, minimizing personnel exposures and waste disposal. However, use of small specimens imposes a variety of challenges as well. These challenges are associated with proper accounting for size effects and transferability of small specimen data to the real structures of interest. Any fracture toughness specimen that can be made out of the broken halves of standard Charpy specimens may have exceptional utility for evaluation of reactor pressure vessels (RPVs) since it would allow one to determine and monitor directly actual fracture toughness instead of requiring indirect predictions using correlations established with impact data. The Charpy V-notch specimen is the most commonly used specimen geometry in surveillance programs. Validation of the mini compact tension specimen (mini-CT) geometry has been performed on previously well characterized Midland beltline Linde 80 (WF-70) weld in the unirradiated condition. It was shown that the fracture toughness transition temperature, To, measured by these Mini-CT specimens is almost the same as To value that was derived from various larger fracture toughness specimens. Moreover, an International collaborative program has been established to extend the assessment and validation efforts to irradiated Linde 80 weld metal. The program is underway and involves the Oak Ridge National Laboratory (ORNL), Central Research Institute for Electrical Power Industry (CRIEPI), and Electric Power Research Institute (EPRI). The irradiated Mini-CT specimens from broken halves of previously tested Charpy specimens of Midland beltline weld have been machined and just arrived to ORNL as part of this international collaboration. The ORNL will initiate tests of the irradiated Linde 80 weld in FY2017 and results of this international program will be reported in FY2018.

42 ENGINEERING↗

Compressed Sensing of Scanning Transmission Electron Microscopy (STEM) With Nonrectangular Scans

Scanning transmission electron microscopy (STEM) has become the main stay for materials characterization on atomic level, with applications ranging from visualization of localized and extended defects to mapping order parameter fields. In recent years, attention has focused on the potential of STEM to explore beam induced chemical processes and especially manipulating atomic motion, enabling atom-by-atom fabrication. These applications, as well as traditional imaging of beam sensitive materials, necessitate increasing the dynamic range of STEM in imaging and manipulation modes, and increasing the absolute scanning speed which can be achieved by combining sparse sensing methods with nonrectangular scanning trajectories. We have developed a general method for real-time reconstruction of sparsely sampled images from high-speed, noninvasive and diverse scanning pathways, including spiral scan and Lissajous scan. This approach is demonstrated on both the synthetic data and experimental STEM data on the beam sensitive material graphene. This work opens the door for comprehensive investigation and optimal design of dose efficient scanning strategies and real-time adaptive inference and control of e-beam induced atomic fabrication.

47 OTHER INSTRUMENTATION↗

Evaluation of Late Effects of Heavy-Ion Radiation on Mesenchymal Stem Cells

The overall objective of this recently funded study is to utilize well-characterized model test systems to assess the impact of pluripotent stem cell differentiation on biological effects associated with high-energy charged particle radiation. These stem cells, specifically mesenchymal stem cells (MSCs), have the potential for differentiation into bone, cartilage, fat, tendons, and other tissue types. The characterization of the regulation mechanisms of MSC differentiation to the osteoblastic lineage by transcription factors, such as Runx2/Cbfa1 and Osterix, and osteoinductive proteins such as members of the bone morphogenic protein family are well established. More importantly, for late biological effects, MSCs have been shown to contribute to tissue restructuring and repair after tissue injury. The complex regulation of and interactions between inflammation and repair determine the eventual outcome of the responses to tissue injury, for which MSCs play a crucial role. Additionally, MSCs have been shown to respond to reactive oxygen species, a secondary effector of radiation, by differentiating. With this, we hypothesized that differentiation of MSCs can alter or exacerbate the damage initiated by radiation, which can ultimately lead to late biological effects of misrepair/fibrosis which may ultimately lead to carcinogenesis. Currently, studies are underway to examine high-energy X-ray radiation at low and high doses, approximately 20 and 200 Rad, respectively, on cytogenetic damage and gene modulation of isolated MSCs. These cells, positive for MSC surface markers, were obtained from three persons. In vitro cell samples were harvested during cellular proliferation and after both cellular recovery and differentiation. Future work will use established in vitro models of increasing complexity to examine the value of traditional 2D tissue-culture techniques, and utilize 3D in vitro tissue culture techniques that can better assess late effects associated with radiation.

Gonda, S.R.↗

Characterization of radiation damage effects in high-energy neutrino target graphite using low-energy ions

Exposure of graphite targets to high intensity proton beams at neutrino production facilities causes changes in the target material that can result in a shortened operation lifetime. The dominant factors in this process are currently thought to be mechanical in nature resulting primarily from microstructural effects that lead to thermal and structural changes in bulk material properties. As currently planned beam facilities with increased proton energy and intensity begin to come online it will be important to thoroughly understand these processes, and ideally to be able to predict the effects of new beam designs on target properties. Direct analysis of targets exposed to existing high-energy proton beams is complicated by several factors, such as very limited access to proton beam facilities, high associated costs, irradiation times on the order of months, and the resulting radioactivity of irradiated samples that requires special facilities for post-irradiation examination. Much of the existing literature concerning irradiation damage in graphite has been focused on the needs of the nuclear engineering community, however high-energy proton targets operate in a much different environment. In comparison to graphite irradiated in a nuclear reactor, graphite used in proton beam targets receives a higher dose rate, have greater gas production, and experience short irradiation pulses as opposed to continuous irradiation. Low-energy ion irradiation offers a method of inducing similar levels of radiation damage to high-energy protons while avoiding many of the difficulties and limitations associated with high-energy proton beams and the corresponding activated specimen testing. My research described in this thesis focused on investigating how low-energy ion irradiation could be used to induce the same or similar types of microstructural alteration and mechanical property degradation as that seen in high-energy neutrino production target graphites by varying damage le vels and irradiation temperatures prior to post-irradiation characterisation.

43 PARTICLE ACCELERATORS↗

Development of Streamlined Nuclear Safety Analysis Tool for Spent Nuclear Fuel Applications

To understand the changing nuclear and mechanical characteristics of spent nuclear fuel (SNF) or used nuclear fuel (UNF) and the different storage, transportation, and disposal systems at various stages within the waste management system, different types of analyses are required. These analyses require the use of assorted tools and numerous types of data. Using the appropriate modeling and simulation (M&S) parameters and selecting from the diversity of analytic tools to conduct SNF analyses can be a tedious, error-prone, and time-consuming undertaking for analysts and reviewers alike. A new, integrated data and analysis system was designed to simplify and automate performance of accurate, efficient evaluations for characterizing the input to the overall U.S. nuclear waste management system—the UNF-Storage, Transportation & Disposal Analysis Resource and Data System (UNF-ST&DARDS). A relational database has been assembled to provide a standard means by which UNF-ST&DARDS can succinctly store and retrieve M&S parameters for specific SNF analysis. A library of various analysis model templates is used to communicate M&S parameters for the most appropriate M&S application. A process manager facilitates performance of actual as-loaded, assembly-specific, and cask-specific evaluations. Interactive visualization capabilities facilitate data analysis and results interpretation. To date, UNF-ST&DARDS has completed (1) explicit depletion and decay analysis of every fuel assembly (~245 000) discharged from commercial U.S. reactors through June 2013, with 13 cooling time steps (results include isotopic compositions for 142 isotopes, and radiation and thermal source terms); (2) SNF radiation dose rate evaluations at 1 m for all the fuel assemblies discharged through June 2013; and (3) criticality, shielding, thermal, and containment analyses of hundreds of loaded casks. In conclusion, UNF-ST&DARDS also provides various automated report generation capabilities with dynamic figure and table update capabilities based on changes to the Unified Database.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗