Search NASA⌕ Search

SEARCH · Search NASA

Results for “EVAPORATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,009 records · Page 56

Materials Performance in USC Steam

Goals of the U.S. Department of Energy’s Advanced Power Systems Initiatives include power generation from coal at 60% efficiency, which requires steam conditions of up to 760 °C and 340 atm. Towards this end, further validation of a previously developed chromia evaporation model is shown by examining the reactive evaporation effects resulting from exposure of Haynes 230 and Haynes 282 to moist air environments as a function of flow rate and water content. These two alloys differ in Ti and Mn contents, which may form outer layers of TiO{sub 2} or Cr-Mn spinels. This would in theory decrease the evaporation of Cr{sub 2}O{sub 3} from the scale by decreasing the activity of chromia at the scale surface, and be somewhat self-correcting as chromia evaporation concentrates the Ti and Mn phases. The apparent approximate chromia activity was found for each condition and alloy that showed chromia evaporation kinetics. As expected, it was found that increasing the gas flow rate led to increased chromia evaporation and decreased chromia activity. However, increasing the water content in moist air increased the evaporation, but results were mixed with its effect on chromia activity.

01 COAL, LIGNITE, AND PEAT↗

Theory of the photomolecular effect

It is well-known that water in liquid and vapor phases exhibits weak visible-light absorption. Recent experiments, however, show that at the liquid-air interface, absorption drastically increases, accelerating evaporation beyond thermal limits by 2–5 times. Strikingly, evaporation peaks at green wavelengths, despite no corresponding absorptance peak. The underlying mechanism of this observation, termed the photomolecular effect, remains puzzling, particularly as water molecules do not exhibit resonance peaks in the visible spectrum. Here, we present a theoretical model explaining the effect. We show that surface-bound water clusters undergo non-resonant photon-driven evaporation, with green light being particularly effective. Crucially, we do not expect green light to couple more strongly than other wavelengths to the molecules at the surface, rather the energy of green light is more effectively used to vaporize water. Our model accounts for why the evaporation peak does not align with absorptance and provides a quantum mechanical explanation of how a single photon can vaporize an entire molecular cluster. This model challenges conventional views on water-light interactions, revealing a fundamentally non-thermal evaporation mechanism. Furthermore, our findings have implications for water purification, energy-efficient drying, and climate modeling, opening new pathways for optimizing evaporation-based technologies.

Interfacial evaporation↗

Deploying effectively dispatchable PV on reservoirs: Comparing floating PV to other renewable technologies

In this article, we present a detailed simulation of floating photovoltaic's (PV) energy yield and associated evaporation reduction potential for the largest 128 US hydropower reservoirs. A recent article by Cavusoglu et al., published in the journal Nature Communications, outlined a hypothetical evaporation engine that could harness the energy of lake water evaporation while simultaneously conserving the water resource. Its authors suggest that evaporation engines deployed across all US lakes and reservoirs could, collectively, yield up to 70% of the total U.S. electricity production. We show that floating PV technology could: (1) deliver considerably more electrical energy than evaporation engines, amounting to 100% of the US production with only a fraction of the lakes; (2) deliver this energy on a firm, effectively dispatchable basis; and (3) conserve as much water as the evaporation engines.

14 SOLAR ENERGY↗

Probing Molecular Assembly of Small Organic Molecules during Meniscus-Guided Coating Using Experimental and Molecular Dynamics Approaches

Evaporation-based thin-film coating processes are ubiquitous in fields such as organic electronics, dye coatings, and the pharmaceutical industry. Based on experimental observations of enhanced thin-film alignment during meniscus-guided coating (MGC), a molecular dynamics simulation was developed to describe the thin-film formation that occurs due to the interplay between evaporation and fluid dynamics. The process of solvent evaporation from solution is first examined, which leads to the formation of a solid thin film after evaporation is complete. Next, an MGC process was simulated by introducing a flow profile coupled with the evaporative system. In this work, we gain insights into how molecules respond and reorient in the presence of a flow profile. These results indicate that both the evaporation and the flow profile have an impact on orienting small molecules in a thin film during the MCG process. Combining experimental techniques with simulations helps enhance the understanding of the forces that are significant in directing molecular aggregation during coating processes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Impact of dynamic specimen shape evolution on the atom probe tomography results of doped epitaxial oxide multilayers: Comparison of experiment and simulation

The experimental atom probe tomography (APT) results from two different specimen orientations (top-down and sideways) of a high oxygen ion conducting Samaria-doped-ceria/Scandia-stabilized-zirconia multilayer thin film solid oxide fuel cell electrolyte was compared with level-set method based field evaporation simulations for the same specimen orientations. This experiment-simulation comparison explains the dynamic specimen shape evolution and ion trajectory aberrations that can induce density artifacts in final reconstruction, leading to inaccurate estimation of interfacial intermixing. This study highlights the importance of comparing experimental results with field evaporation simulations when using APT to study oxide heterostructure interfaces.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Investigation of primordial black hole bursts using interplanetary network gamma-ray bursts

The detection of a gamma-ray burst (GRB) in the solar neighborhood would have very important implications for GRB phenomenology. The leading theories for cosmological GRBs would not be able to explain such events. The final bursts of evaporating primordial black holes (PBHs), however, would be a natural explanation for local GRBs. We present a novel technique that can constrain the distance to GRBs using detections from widely separated, non-imaging spacecraft. This method can determine the actual distance to the burst if it is local. We applied this method to constrain distances to a sample of 36 short-duration GRBs detected by the Interplanetary Network (IPN) that show observational properties that are expected from PBH evaporations. These bursts have minimum possible distances in the 10 13 –10 18 cm (7–10 5 au) range, which are consistent with the expected PBH energetics and with a possible origin in the solar neighborhood, although none of the bursts can be unambiguously demonstrated to be local. Furthermore, assuming that these bursts are real PBH events, we estimate lower limits on the PBH burst evaporation rate in the solar neighborhood.

79 ASTRONOMY AND ASTROPHYSICS↗

Treatment of radioactive liquid waste by the forced-air exhaust system - 15190

A Natural Evaporation Facility (NEF) was constructed to treat low level (LL) radioactive liquid waste arising from a Radioactive Waste Treatment Facility (RWTF) at the Korea Atomic Energy Research Institute (KAERI). In order to process LL radioactive liquid waste, we investigated the influence of climate condition, mainly atmospheric humidity and temperature, on the amount of evaporation in a forced-air exhaust system in KAERI. Evaporation media were made of cotton and polyester. Air exhaust in the facility was forced by exhaust fans. The evaporation rate and the decontamination factor were calculated and reported as shown in the results section. The evaporation and air supply flow increased at the same rate. In addition, the liquid waste feed rate and temperature of supplied air increased. Regarding the relative humidity of supplied air, the evaporation rate increased as the relative humidity decreased. As the result of this study, the operating conditions for the NEF were optimized in the following areas: The air temperature above 8 deg. C, the air relative humidity below 70%, the air flow rate 1.14-1.47 m/sec, and the liquid waste feed rate 4.6 l/hr.m{sup 2}. The decontamination factor was 1.1x10{sup 3}. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Utilizing Commercial Submersible Mixer Pumps for Sludge Removal in Savannah River Site's Tank 26 - 20289

The Savannah River Site (SRS) Liquid Waste System (LWS) safely manages, stores, treats, and dispositions liquid radioactive waste. The LWS consists of 51 underground waste storage tanks (eight of which are operationally closed and filled with grout), waste evaporators, treatment facilities, and solidification facilities, known as the Defense Waste Processing Facility (DWPF) and Saltstone Production Facility (SPF). One of the waste storage tanks, Tank 26, was placed into service in 1980 as an F Tank Farm (FTF) Evaporator Feed Tank. From 1980 to 2013, Tank 26 received F Canyon receipts and dilute supernate that was then transferred to the 242-16F FTF Evaporator for volume reduction. In 2013, the steam tube bundle failed in the FTF Evaporator, and the decision was made not to repair/resume evaporator operation. During operation of Tank 26, solids built up to a level of 2.03 m in the tank with a volume of 1062.9 kL. Due to the evaporator failure and subsequent shutdown, the solids in Tank 26 were selected to feed Sludge Batch 10, which is collected and prepped prior to being sent to DWPF for final disposition. To accomplish solids removal, Commercial Submersible Mixer Pumps (CSMPs) were selected to slurry the solids in preparation to be sent to Tank 51. Four CSMPs were installed in Tank 26 with each one installed in a separate quadrant of Tank 26. This work would mark the first deployment of CSMPs in an SRS waste tank. The CSMPs were developed in response to operational issues from previous mixing pumps and budgetary constraints. The CSMPs use the concept of modifying commercially available equipment for nuclear waste applications. The CSMPs consist of a 230-horsepower submersible mixing pump (manufactured by GPM, Inc.) joined to a mast fabricated at SRS. For this application, Savannah River Remediation (SRR) design services was challenged to provide a mast design that required no steel superstructure support system on top of Tank 26. Also, SRR design services provided a simplified Tank 26 riser interface that did not require extensive machine parts to adjust height of the suction screen of the CSMP within the tank. Other design improvements include no requirements for tank top radiation monitors and no requirements for flushing of the CSMPs during startup/shutdown operations. The CSMPs were operated at an initial height of 2.29 m above the Tank 26 bottom for 10 days. After sludge sounding, the CSMPs were lowered to a height of 1.52 m with no issues due to proper work planning and the simplified riser interface. With the CSMPs lowered to a level of 1.52 meters above the tank bottom, the CSMPs were operated for 12 days and another sounding was performed. The sounding level came back matching the disturbance depth results of the first pump run. Chemistry samples were analyzed while the tank was left to settle. The analysis revealed enough weight percent solids to provide good feed to Sludge Batch 10. Also, the results revealed the supernate within the mixture would provide good salt solution feed to Salt Waste Processing Facility (SWPF) Salt Batch 3. So, the plan was modified to let the disturbed solids settle and decant the salt solution for addition to SWPF Salt Batch 3. Then water will be added back to Tank 26, and the CSMPs run in order to wash the solids to decrease settling time prior to being sent to Tank 51 for Sludge Batch 10. Utilizing CSMPs for waste removal in an SRS Tank has provided a cost-effective means for further waste removal efforts. In addition, the CSMPs are easier to operate by utilizing a robust and simplified design. The CSMPs performed quite well with no process shutdown or delays during operation. As a result, CSMPs are integral to the future of removing radioactive waste from storage tanks at SRS. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Thermal Response of a Lithium Vapor Divertor to Cyclical Operation

The lithium vapor divertor concept is being developed as a method to achieve detached divertor conditions in a tokamak while minimizing impurity radiation losses from the core plasma. SOLPS-ITER modeling has previously been used to identify some of the geometric constraints and required lithium evaporation rate of a lithium vapor divertor in a medium-sized tokamak during steady-state operation. Here an updated conceptual design based on these operating requirements is introduced and the thermal response of the system is modeled during cyclical operation, consistent with operation in a short-pulse tokamak. Controllability of the temperature of the lithium capillary porous system (CPS) is achieved by adopting a design where there is no line-of-sight for radiation from the plasma to reach the heated CPS surface. Operational strategies to minimize the amount of lithium evaporated between plasma discharges while achieving steady evaporation rates during plasma discharges are discussed and modeled here. The optimal feedforward control strategy demonstrated in this work is to ramp up the temperature of the evaporator as quickly as possible immediately before a plasma discharge and then reduce the heating to match the desired steady-state net evaporation rate just before the plasma discharge begins, allowing the thermal inertia of the system to stabilize the evaporation rate during the first second of the plasma discharge.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Falling-film thermosyphons: Application to water harvesting from humid gas streams

Water harvesting from humid gas streams is central to fresh-water production, desalination, and particulate removal from combustion gas streams. Two-phase thermosyphons are well suited for these applications due to their very low thermal resistance, but have several operating limits at the high heat flows required for such applications. This work introduces the falling-film thermosyphon for large-scale condensation applications. Working fluid is pumped to the top of the evaporator to provide the evaporating liquid film on the inner tube wall, rather than by vapor condensation. The flooding, dry-out and pool-boiling limits are eliminated, resulting in significantly higher maximum heat fluxes for the same physical evaporator size. Furthermore, the condenser no longer needs to be located vertically above the evaporator, which allows for a standard steam condenser to be used. A model for the condensation process in humid air was developed that estimates the fluid and heat transfer and is confirmed experimentally. Further benefits include the use of a high-thermal-conductivity polymer material for the evaporator section to minimize corrosion, and the ability to impose a temperature boundary condition on the evaporator, which is made possible due to the elimination of a liquid pool.

42 ENGINEERING↗

Drizzle and Turbulence below closed cellular marine stratocumulus clouds

Drizzle is ubiquitous in marine boundary layer stratocumulus clouds with much of it evaporating before reaching the surface. Ten days of observations made at the Atmospheric Radiation Measurement (ARM)’s Eastern North Atlantic (ENA) site during closed cellular stratocumulus cloud conditions are used to characterize drizzle below the cloud base and its impact on the boundary layer turbulence. Cloud and drizzle micro- and macro-physical properties were retrieved by combining the data from vertically pointing Doppler cloud radar, ceilometer, and microwave radiometer. On average the drizzle shafts were 28.14 km wide, with cloud base rain rate and modal diameter of 1.26 mm day-1 and 145.26 µm respectively. The rain rate at the surface was negligible yielding an average diabatic cooling of -30.60 Wm-2 in the sub-cloud layer. The LWP and turbulence within the boundary layer increased with an increase in the cloud top radiative cooling, however none of these variables exhibited any relationship with cloud base rain rate. For a similar amount of radiative cooling at the cloud top, the average variance of vertical velocity in the sub-cloud layer was about 10% lower during strongly precipitating conditions as compared to lightly precipitating conditions. The reduction in the variance of vertical velocity due to drizzle evaporation was primarily confined to the upper half of the sub-cloud layer and was due reduction in the strengths of the downdrafts. Collectively our results show substantial impact of drizzle evaporation on boundary layer turbulence, necessitating its accurate representation in the Earth System Models.

drizzle↗

Integrated cooling (i-Cool) textile of heat conduction and sweat transportation for personal perspiration management

Perspiration evaporation plays an indispensable role in human body heat dissipation. However, conventional textiles tend to focus on sweat removal and pay little attention to the basic thermoregulation function of sweat, showing limited evaporation ability and cooling efficiency in moderate/profuse perspiration scenarios. Here, we propose an integrated cooling (i-Cool) textile with unique functional structure design for personal perspiration management. By integrating heat conductive pathways and water transport channels decently, i-Cool exhibits enhanced evaporation ability and high sweat evaporative cooling efficiency, not merely liquid sweat wicking function. In the steady-state evaporation test, compared to cotton, up to over 100% reduction in water mass gain ratio, and 3 times higher skin power density increment for every unit of sweat evaporation are demonstrated. Besides, i-Cool shows about 3 °C cooling effect with greatly reduced sweat consumption than cotton in the artificial sweating skin test. The practical application feasibility of i-Cool design principles is well validated based on commercial fabrics. Owing to its exceptional personal perspiration management performance, we expect the i-Cool concept can provide promising design guidelines for next-generation perspiration management textiles.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Nonsingular black holes as dark matter

It is commonly assumed that low-mass primordial black holes cannot constitute a significant fraction of the dark matter in our universe due to their predicted short lifetimes from the conventional Hawking radiation and evaporation process. Assuming physical black holes are nonsingular—likely due to quantum gravity or other high-energy physics—we demonstrate that a large class of nonsingular black holes have finite evaporation temperatures. This can lead to slowly evaporating low-mass black holes or to remnant mass states that circumvent traditional evaporation constraints. As a proof of concept, we explore the limiting curvature hypothesis and the evaporation process of a nonsingular black hole solution in two-dimensional dilaton gravity. We identify generic features of the radiation profile and compare them with known regular black holes, such as the Bardeen solution in four dimensions. Remnant masses are proportional to the fundamental length scale, and we argue that slowly evaporating low-mass nonsingular black holes, or remnants, are viable dark matter candidates. Published by the American Physical Society 2025

79 ASTRONOMY AND ASTROPHYSICS↗

Clumped isotope constraints on changes in latest Pleistocene hydroclimate in the northwestern Great Basin: Lake Surprise, California

Abstract During the Last Glacial Maximum (LGM) and subsequent deglaciation, the Great Basin in the southwestern United States was covered by numerous extensive closed-basin lakes, in stark contrast with the predominately arid climate observed today. This transition from lakes in the Late Pleistocene to modern aridity implies large changes in the regional water balance. Whether these changes were driven by increased precipitation rates due to changes in atmospheric dynamics, decreased evaporation rates resulting from temperature depression and summer insolation changes, or some combination of the two remains uncertain. The factors contributing to these large-scale changes in hydroclimate are critical to resolve, given that this region is poised to undergo future anthropogenic-forced climate changes with large uncertainties in model simulations for the 21st century. Furthermore, there are ambiguous constraints on the magnitude and even the sign of changes in key hydroclimate variables between the Last Glacial Maximum and the present day in both proxy reconstructions and climate model analyses of the region. Here we report thermodynamically derived estimates of changes in temperature, precipitation, and evaporation rates, as well as the isotopic composition of lake water, using clumped isotope data from an ancient lake in the northwestern Great Basin, Lake Surprise (California). Compared to modern climate, mean annual air temperature at Lake Surprise was 4.7 °C lower during the Last Glacial Maximum, with decreased evaporation rates and similar precipitation rates to modern. During the mid-deglacial period, the growth of Lake Surprise implied that the lake hydrologic budget briefly departed from steady state. Our reconstructions indicate that this growth took place rapidly, while the subsequent lake regression took place over several thousand years. Using models for precipitation and evaporation constrained from clumped isotope results, we determine that the disappearance of Lake Surprise coincided with a moderate increase in lake temperature, along with increasing evaporation rates outpacing increasing precipitation rates. Concomitant analysis of proxy data and climate model simulations for the Last Glacial Maximum are used to provide a robust means to understand past climate change, and by extension, predict how current hydroclimates may respond to expected future climate forcings. We suggest that an expansion of this analysis to more basins across a larger spatial scale could provide valuable insight into proposed climate forcings, and aid in climate model process depiction. Ultimately, our analysis highlights the importance of temperature-driven evaporation as a mechanism for lake growth and retreat in this region.

Geology↗

Innovative thermal distillation method using solar heat localization

The thermal distillation uses energy to evaporate water and subsequently condense the vapor to liquid form. Waste energy from industrial processes, electricity, or solar energy are the examples of an input energy for thermal distillation systems. In this paper, we have designed, fabricated, and tested an eco-friendly and low- cost distillation system which uses solar heat localization for evaporation of water and later condense the vapor back to liquid as liquid water. The unique feature of this method is the high rate of evaporation when compared to other thermal solar distillation/desalination systems. In this method, the incoming heat is confined to the porous media where bottom layer acts a porous insulator. The capillary force in the porous structure pumps up the liquid water to the hot surface, within the porous medium, where liquid heats up and changes to vapor phase. Since there is no moving part in this method, and due to its independency to electricity, it a great candidate for deployment in remote areas that access to grid power is limited and maintenance is not feasible.

Jaladi, Divya↗

Numerical case study of the aerosol–cloud interactions in warm boundary layer clouds over the eastern North Atlantic with an interactive chemistry module

The presence of warm boundary layer stratiform clouds over the eastern North Atlantic (ENA) region is commonly influenced by the Azores High, especially during the summer season. To investigate comprehensive aerosol–cloud interactions, this study employs the Weather Research and Forecasting model coupled with a chemistry component (WRF-Chem), incorporating aerosol chemical components that are relevant to the formation of cloud condensation nuclei (CCN) and accounting for aerosol spatiotemporal variation. This study focuses on aerosol indirect effects, particularly the long-range transport of aerosols, in the ENA region under three different weather regimes: a ridge with a surface high-pressure system, a post-trough with a surface high-pressure system, and a weak trough. The WRF-Chem simulations conducted at a near-large-eddy scale offer valuable insights into the model's performance, especially in terms of its ability to use high spatial resolution to capture mesoscale cloud features across various weather regimes. Our result shows that introducing 5 times more aerosols to either non-precipitating or precipitating clouds significantly increases ambient CCN numbers, resulting in, to varying degrees, higher liquid water path (LWP) values. The substantial aerosol–cloud interaction especially occurs in the precipitating clouds and demonstrates the susceptibility of the LWP to changes in CCN under different regimes. Conversely, thin, non-rain clouds at the edges of a cloud system are prone to evaporation, exhibiting an aerosol drying effect. The aerosols released during this process transition back to the accumulation mode, facilitating future activation. This dynamic behavior is not adequately represented in prescribed-aerosol simulations.

54 ENVIRONMENTAL SCIENCES↗

Retrofit device to improve vapor compression cooling system performance by dynamic blower speed modulation

A device and method are provided to improve performance of a vapor compression system using a retrofittable control board to start up the vapor compression system with the evaporator blower initially set to a high speed. A baseline evaporator operating temperature with the evaporator blower operating at the high speed is recorded, and then the device detects if a predetermined acceptable change in evaporator temperature has occurred. The evaporator blower speed is reduced from the initially set high speed as long as there is only a negligible change in the measured evaporator temperature and therefore a negligible difference in the compressor's power consumption so as to obtain a net increase in the Coefficient of Performance.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Refrigeration system having dual suction port compressor

A cooling system for appliances, air conditioners, and other spaces includes a compressor, and a condenser that receives refrigerant from the compressor. The system also includes an evaporator that receives refrigerant from the condenser. Refrigerant received from the condenser flows through an upstream portion of the evaporator. A first portion of the refrigerant flows to the compressor without passing through a downstream portion of the evaporator, and a second portion of the refrigerant from the upstream portion of the condenser flows through the downstream portion of the evaporator after passing through the upstream portion of the evaporator. The second portion of the refrigerant flows to the compressor after passing through the downstream portion of the evaporator. The refrigeration system may be configured to cool an appliance such as a refrigerator and/or freezer, or it may be utilized in air conditioners for buildings, motor vehicles, or other such spaces.

42 ENGINEERING↗