Search NASA⌕ Search

SEARCH · Search NASA

Results for “Environmental Testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,009 records · Page 56

Engineered Solutions Group's SMR Containment Cable and Electrical Penetration Assembly System

GAIN Project CRADA Number NFE-21-08839, entitled “SMR Containment Cable and EPA System” was initiated by the partnership of Oak Ridge National Laboratory (ORNL) and Engineered Solutions Group (ESG) to test an ESG-designed Electrical Penetration Assembly and Containment Cabling System Qualified for not only legacy LWR designs, but also Small Modular Reactors designs currently being designed by several different suppliers. This project was undertaken to fill the equipment gap of EPA and Cabling Systems that require much more severe environmental requirements than legacy plant applications present due to their smaller containment volumes that result in high energy densities compared to legacy designs. This high energy density results in severe accident environments and more severe normal operating conditions as well. We developed two approaches to qualify Electrical Penetration Assembly (EPA) and Containment Cabling Systems for SMRs and Advanced Reactors. We take into consideration the more severe environmental parameters found with SMR designs. The system will need to meet a qualification test program addressing wear/cyclic aging, potential radiation exposure, thermal aging, vibration aging, thermal cycling, seismic qualification, electrical fault testing (per IEEE 317) and accident simulation. The equipment must meet the requirements of 10CFR50.49, GDC 50 in 10CFR50 Appendix A, and 10CFR50 Appendix J. NRC Regulatory Guides (RGs) identify an acceptable way of meeting regulatory requirements. RGs frequently endorse a standard for meeting these requirements. Specific to this review, equipment would be qualified in accordance with the following IEEE Standards. • IEEE 317-2013 (Electrical Penetration Assemblies), which is endorsed by RG 1.63, Rev. 3, • IEEE 323-2003 and the more current IEC/IEEE 60780-323 (Environmental Qualification of 1E Equipment) which is endorsed by RG 1.89. IEEE 323-2003 is endorsed by RG 1.209, • IEEE 344-2020 (Seismic Qualification. The 2013 version endorsed by RG 1.100, Rev. 4, with exceptions), • IEEE 383-2015 (Electrical Cables) (which is endorsed by RG 1.189 Rev. 4 and the -2003 version endorsed by RG 1.211 rev. 0), • IEEE 572-2019 (Electrical Connectors and Assemblies), which is endorsed by 1.156 Rev 1, and • [IEEE 1202 (endorsed by RG 1.189) would normally be applicable but the advanced cable designs are impervious to this cable flame test.] The primary goal of such a program is to provide an EPA design that can meet the qualification requirements for all legacy light water reactor plants currently operating as well as new plant designs including light water Small Modular Reactors. Thus, these requirements are applicable to plants licensed under 10CFR50 and 10CFR52. Other reactor designs may be evaluated, and this test system and qualification method applied to those applications if the requirements would satisfy the requirements of the intended plant. A secondary benefit of this work is to document some of the history and background in these requirements as there have been recent delays in an SMR licensing process due to NRC Requests for Additional Information in this subject matter area.

42 ENGINEERING↗

Syracuse University Test Report On Uptake Factor Resulting From A Dropped Storage Container

Under certain circumstances, powder from an accidently dropped container can become airborne and inhaled by people nearby such as those who are moving the containers. The inhaled fine particles can deposit on respiratory tracts and lungs, causing asthma, lung cancer, and other acute respiratory illnesses and chronic symptoms. The objective of this study was to develop a standard procedure to measure the airborne concentrations of different size particles within the vicinity of a dropped container where a significant portion of the contained powder is ejected. Tungsten oxide (WO{sub 3}) was selected in this study to represent relatively heavy powders (7.16 g/cm3 specific gravity for WO{sub 3}). A typical can with the outer dimensions of 4.25” diameter and 4.875” tall was used as the container. The powder was dropped in two different configurations: 1) contained within a can covered by a lid that has a 0.25” diameter hole, and 2) contained within a can without a lid. The packing volume of the powder was 51.4 in{sup 3} (842.7 cm{sup 3}) and the target mass was 1936 g. The tests were carried out in a full-scale stainless steel environmental chamber with an interior volume of 852 ft{sup 3} (24.1 m{sup 3}). The chamber system includes an internal recirculation loop with a rectangular air diffuser and 10 variable frequency drive fans to provide a typical room air recirculation flow pattern. Two air filters were installed in the chamber air supply duct and return duct to achieve the required low background particle concentration. The initial chamber air conditions were set at 70°F (± 5°F) and 50% (± 10%) RH. A supporting frame and releasing device were designed and built to trigger consistently the dropping of the can at a height of 8 feet from the bottom of the can to the impacting surface. The particle sampling inlet was placed 5 ft above the floor and 6 inches laterally away from the can’s falling path. Concentrations of particles between 0.5 μm and 20 μm were recorded in units of mass and number of particles per unit volume. The data acquisition rate was once every 2 seconds during the first 2 hours and every 20 seconds thereafter. A test procedure was developed and a total of nine drop tests were performed. In most cases (seven tests), the can tipped over after dropping. The can in Test 1 stayed upright. The can in Test 7 showed a special behavior: after the rebound, it turned upside down and stayed upright. Major findings are summarized below: The amount of spilled powder varied from 0.12 g to 252.35 g and the non-recovered powder varied from 0.11 g to 1.18 g. The corresponding percentage of the spilled powder ranged from 0.01% to 13%;The peak value of particle number concentration after the dropping of the can occurred at approximately 0.9 μm particle size per measured data of individual channels. The peak value of particle mass concentration occurred in the range of 4.3 - 10 μm particle size per grouped data calculated from the measured data with the exception of Test 4 where a different batch powder with unexpectedly different bulk density and particle size distribution; After the dropping of the can, the total airborne mass concentrations ranged from 0.03 to 0.35 mg/m{sup 3}, while the total airborne number concentrations ranged from 2 to 125 #/cm{sup 3} except for Test 4. The number concentration in Test 4 was 1 or 2 orders of magnitude less than those of other tests because the powder was from a different batch. However, its mass concentration was comparable to that in Test 7 because relatively more big airborne particles were detected in Test 4. In general, tests with lid (Test 5, 6, 7 and 8) had smaller concentrations than tests without lid (Test 0, 1, 2, and 3). The influence of lid was not as prominent as the powder (Test 4). However, this needs more tests for verification; The ratio of airborne mass to non-recovered mass ranged from 0.1% to 2%. This means that it is challenging to use this method to check the mass balance, while the uptake factor and associated inhalation exposure can be readily assesse; The calculated cumulative uptake mass within first 10 minutes after the dropping of the can for each test was within the range of 0.002 mg to 0.035 mg. Assuming a breathing rate of 1.2 m{sup 3}/h, the uptake factor during the first 10 minutes was calculated to be between 10{sup -9} and 2×10{sup -8} in reference to the amount loaded; or between 10{sup -8} and 6×10{sup -5} in reference to the amount spilled. The experimental results of this study will be useful for standardizing the test method and provide data for estimating the exposure and associated risk to building occupants in the case of an accidental dropping of heavy powder containers.

42 ENGINEERING↗

Life cycle costing of waste management systems: Overview, calculation principles and case studies

Highlights: • We propose a comprehensive model for cost assessment of waste management systems. • The model includes three types of LCC: Conventional, Environmental and Societal LCCs. • The applicability of the proposed model is tested with two case studies. - Abstract: This paper provides a detailed and comprehensive cost model for the economic assessment of solid waste management systems. The model was based on the principles of Life Cycle Costing (LCC) and followed a bottom-up calculation approach providing detailed cost items for all key technologies within modern waste systems. All technologies were defined per tonne of waste input, and each cost item within a technology was characterised by both a technical and an economic parameter (for example amount and cost of fuel related to waste collection), to ensure transparency, applicability and reproducibility. Cost items were classified as: (1) budget costs, (2) transfers (for example taxes, subsidies and fees) and (3) externality costs (for example damage or abatement costs related to emissions and disamenities). Technology costs were obtained as the sum of all cost items (of the same type) within a specific technology, while scenario costs were the sum of all technologies involved in a scenario. The cost model allows for the completion of three types of LCC: a Conventional LCC, for the assessment of financial costs, an Environmental LCC, for the assessment of financial costs whose results are complemented by a Life Cycle Assessment (LCA) for the same system, and a Societal LCC, for socio-economic assessments. Conventional and Environmental LCCs includes budget costs and transfers, while Societal LCCs includes budget and externality costs. Critical aspects were found in the existing literature regarding the cost assessment of waste management, namely system boundary equivalency, accounting for temporally distributed emissions and impacts, inclusions of transfers, the internalisation of environmental impacts and the coverage of shadow prices, and there was also significant confusion regarding terminology. The presented cost model was implemented in two case study scenarios assessing the costs involved in the source segregation of organic waste from 100,000 Danish households and the subsequent co-digestion of organic waste with animal manure. Overall, source segregation resulted in higher financial costs than the alternative of incinerating the organic waste with the residual waste: 1.6 M€/year, of which 0.9 M€/year was costs for extra bins and bags used by the households, 1.0 M€/year for extra collections and −0.3 M€/year saved on incineration.

09 BIOMASS FUELS↗

Demonstration of Combined Zero-Valent Iron and Electrical Resistance Heating for In Situ Trichloroethene Remediation

The effectiveness of in situ treatment using zero-valent iron to remediate sites with non-aqueous phase or significant sediment-associated contaminant mass can be limited by relatively low rates of mass transfer to bring contaminants in contact with the reactive media. For a field test in a trichloroethene source area, combining moderate-temperature (maximum 50oC) subsurface electrical resistance heating with in situ ZVI treatment was shown to accelerate dechlorination and dissolution rates by a factor of 4 to 6 based on organic daughter products and a factor 8-16 using a chloride concentrations. A mass-discharge-based analysis was used to evaluate reaction, dissolution, and volatilization at ambient groundwater temperature (~10oC) and as temperature was increased up to about 50oC. Increased reaction and contaminant dissolution were observed with increased temperature, but volatilization was minimal during the test because in situ reactions maintained low aqueous-phase TCE concentrations.

54 ENVIRONMENTAL SCIENCES↗

Development of Technologies and Capabilities for Coal Energy Resources

This is the final report for the Aerojet Rocketdyne (AR) Advanced Gasification Systems Development (AGSD) project that was initiated on October 1, 2004. The project’s primary objective is to demonstrate technologies that improve the availability and efficiency of gasification-based power plants and to reduce plant capital and operational costs. The objective will be accomplished by (1) development and testing of cooled refractory liners, (2) feed system development and demonstration, (3) pilot plant definition and planning, (4) transport gasifier feed analysis, (5) coal-biomass mixture feed analysis, and (6) coal-biomass mixture pilot scale tests. Task 1, development and testing of cooled refractory liners, was conducted at CANMET Energy Technology Centre in Ottawa, Canada. The test objectives were to screen high conductivity CMC materials with alternate manufacturing methods and a variety of surface treatments for cooled metal tubes in a slagging gasifier environment. During the CMC testing, it was found that a constantly cooled CMC will survive in good conditions and that high porosity CMC resulted in high material erosion and corrosion. During cooled tube testing, it was found that hard metal spray coat and bare Haynes 188 performed the best. Task 2, feed system development and demonstration, was conducted at at the Energy and Environmental Research Center (EERC) at the University of North Dakota (UND). For tasks 2.1-2.6, the test objective was to demonstrate 400-tons/day coal feed system operation (to 1,000 psia gasifier pressures) in ultra-dense phase flow without plugging and to achieve multi-element injector flow-split non-uniformities below 2 %RSD. Testing was successfully completed with no feed system plugging of the feed system. The majority of the other Task 2 activities were associated with the Dry Solids Pump design (Task 2.8 and 2.11), development (Task 2.10), fabrication (Task 2.12), amd testing (Task 2.13-2.15). A variety of tests were performed that verified the capability of the Dry Solids Pump to consolidate various pulverized feedstocks to a state capable of sealing and sustaining downstream outlet pressures during mechanical operation of the pump as well as during periods when the pump was turned off. However, the final operating goals were not achieved. Task 3, pilot plant definition and planning, was to define requirements for an advanced commercial gasifier with a cooled liner and to establish a preferred commercial gasifier system configuration to serve as the reference point for an advanced gasifier pilot plant concept definition. A pilot plant concept was successfully defined that is scalable and traceable to the commercial gasifier configuration. The schedule and cost for design, installation, and long-duration test operation of a pilot plant were estimated at 33 months and $\$$25.6M. Taks 4, transport gasifier feed analysis, was to determine the effects of larger sized transport gasifier low rank coals within the AR dry solids pump. It was found for the two low-rank +100 mesh size transport gasifier coals that the cohesion of these larger materials was significantly less than the coals ground to minus 200 mesh. Also, the gas permeability of the MSL transport coal was found to be significantly higher than the permeability of the PRB transport coal. Task 5, coal-biomass mixture feed analysis, was to determine the effects of coal biomass blends within the AR ultra-dense phase feed system and dry solids pump, and to determine the cost of electricity increase of an integrated gasification combined cycle (IGCC) operating on coal/biomass blends with the AR dry solids pump and ultra-dense phase feed system. In summary, it was found that 75/25 wt% coal/corn stover blends produce reasonable economic results for IGCC operation with minimal dry solids pump modifications – especially if the coal is a low rank coal and the corn stover biomass is pelletized. The increase in electricity cost was found to be 1.1 cents/kWh. Task 6, coal-biomass mixture pilot scale tests, was to determine which coal/biomass blends could be tested in the current dry solids pump without major modifications. As reported in detail in the reports by Sprouse (2010) and Sprouse and Darby (2013), the coal/biomass blend having the least impact on pump configuration and operation is the 90/10 wt% Illinois #6 to corn stover ratio blend. The AGSD program was initiated on October 1, 2004. The interim final report was submitted on October 21, 2010 and covered Task 1, Task 2.1-2.9, and Task 3, performed during budget period 1. This final report covers Task 2.10-2.16, 4, 5, and 6, performed during budget period 2. The interim final report is attached as part of the appendix to this report.

Darby, Alan K.↗

Overview of Nevada Test Site Radioactive and Mixed Waste Disposal Operations

The U.S. Department of Energy (DOE), National Nuclear Security Administration Nevada Site Office Environmental Management Program is responsible for carrying out the disposal of on-site and off-site generated low-level radioactive waste (LLW) and low-level radioactive mixed waste (MW) at the Nevada Test Site (NTS). Core elements of this mission are ensuring safe and cost-effective disposal while protecting workers, the public, and the environment. This paper focuses on the impacts of new policies, processes, and opportunities at the NTS related to LLW and MW. Covered topics include: the first year of direct funding for NTS waste disposal operations; zero tolerance policy for non-compliant packages; the suspension of mixed waste disposal; waste acceptance changes; DOE Consolidated Audit Program (DOECAP) auditing; the 92-Acre Area closure plan; new eligibility requirements for generators; and operational successes with unusual waste streams.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

EPA GHG certification of medium- and heavy-duty vehicles: Development of road grade profiles representative of US controlled access highways

In collaboration with the U.S. Environmental Protection Agency and the U.S. Department of Energy, the National Renewable Energy Laboratory has conducted a national analysis of road grade characteristics experienced by U.S. medium- and heavy-duty trucks on controlled access highways. These characteristics have been developed using TomTom's commercially available street map and road grade database. Using the TomTom national road grade database, national statistics on road grade and hill distances were generated for the U.S. network of controlled access highways. These statistical distributions were then weighted using data provided by the U.S. Environmental Protection Agency for activity of medium- and heavy-duty trucks on controlled access highways. Here, the national activity-weighted road grade and hill distance distributions were then used as targets for development of a handful of sample grade profiles potentially to be used in the U.S. Environmental Protection Agency's Greenhouse Gas Emissions Model certification tool as well as in dynamometer testing of medium- and heavy-duty vehicles and their powertrains.

30 DIRECT ENERGY CONVERSION↗

Lessons Learned from Ecosystem-Scale Experimental Field Studies (Workshop Report)

Efforts to understand and predict ecosystem responses to environmental change require long-term, large-scale, spatially representative experiments and observations that capture natural variability, test predictive models, and generate transferable knowledge. Such studies are indispensable for unraveling the complexities of terrestrial ecosystems and their responses to disturbances and evolving environmental conditions, while generating the data necessary for developing mechanistic models and predictive tools that inform decision-making processes. Having a rich history of designing and executing large-scale ecosystem experiments, the U.S. Department of Energy’s Environmental System Science program convened a workshop in January 2025 that brought together leaders in the field to distill critical lessons from decades of experience in large-scale experiments. The workshop aimed to (1) provide an ecosystem experiment primer for best practices, thus ensuring a high scientific return on investment for funding agencies, and (2) offer a robust framework for the design and management of future research initiatives. This report synthesizes insights and experiences from workshop participants and is structured to capture the entire research life cycle, from goal setting and design to operations, adaptive management, team dynamics, collaborations, and the often overlooked aspect of decommissioning. By synthesizing decision-making and lessons learned across diverse research approaches, the report aims to provide a template of essential factors to consider when designing successful long-term, large-scale ecosystem experiments.

54 ENVIRONMENTAL SCIENCES↗

Cost, Energy, and Environmental Impact of Automated Electric Taxi Fleets in Manhattan

It has been shown that shared automated electric vehicles (SAEVs) hold great promise for improving transportation access in urban centers while drastically reducing transportation-related energy consumption and air pollution. Using taxi-trip data from New York City, we develop an agent-based model to predict the battery range and charging infrastructure requirements of a fleet of SAEVs operating on Manhattan Island. We also develop a model to estimate the cost and environmental impact of providing service and perform extensive sensitivity analysis to test the robustness of our predictions. We estimate that costs will be lowest with a battery range of 50-90 mi, with either 66 chargers per square mile, rated at 11 kW or 44 chargers per square mile, rated at 22 kW. We estimate that the cost of service provided by such an SAEV fleet will be $0.29-$0.61 per revenue mile, an order of magnitude lower than the cost of service of present-day Manhattan taxis and $0.05-$0.08/mi lower than that of an automated fleet composed of any currently available hybrid or internal combustion engine vehicle (ICEV). We estimate that such an SAEV fleet drawing power from the current NYC power grid would reduce GHG emissions by 73% and energy consumption by 58% compared to an automated fleet of ICEVs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Final Scientific/Technical Report-FREE-piston Zero Emissions Refrigerator (FREEZER)

The FREE-piston Zero Emissions Refrigerator (FREEZER™) is a natural refrigerant Stirling-cycle cooler developed by AMSC in partnership with Heatcraft, targeted as a replacement refrigeration system for walk-in coolers or freezers found commonly in restaurants, convenience stores, supermarkets, etc. The FREEZER™, combined with a closed-loop CO2 heat-transfer system, had the goal to provides an efficient (Target COP = 1.4), zero ODP (Ozone Depletion Potential) and near zero GWP (Global Warming Potential) refrigeration solution with no synthetic, flammable, or toxic refrigerants. Other near zero GWP refrigeration systems do not exist at the scale and performance level of FREEZER. ARPA-E Continuation Funding enabled the design and fabrication of one Advanced Development Unit (ADU) cooler and two Field Test Unit (FTU) coolers, and a new revised Field Test Unit (new FTU). Heatcraft was to extensively test the various coolers at their facilities, which closely simulate real-world conditions. The original plan was to install and operate FREEZER FTUs alongside a traditional cooling solution at one or more customer locations to obtain data on direct performance comparisons with existing commercial refrigeration systems. Success in this FREEZER refinement and field-test project will establish the basis for a new class of environmentally friendly refrigeration systems that will revolutionize the industry. The hardware developed under the program is shown below in Figure 1. Five Stirling-cycle machines were built within the program, with a sixth cooler still under construction. The original DU and the ADU coolers met the performance target with a coefficient of performance (COP) of 1.2. The FTU was underperforming during the initial tuning of the free-piston Stirling cycle dynamics when there was a catastrophic failure of the fasteners on pressure boundary. This caused a pause to the program while the failure mechanism was investigated. The root cause was an inadequate flange design that allowed an excessive cyclic loading on the fasteners, leading to a fatigue failure. It was determined that existing FTU design could not be reasonably salvaged in a safe manner, and that fact, combined with the lower-than-expected performance of the new experimental heat exchanger modules lead to the design of the “new FTU” with a more conventional shell-and-tube heat exchanger design which should get close to the design target COP of 1.4, but have a higher overall machine cost. The program ran out of time before the fabrication of the new FTU was completed, but AMSC is still working on the cooler, with the majority of the parts fabricated, and hopes to have the unit under test sometime in early 2022, after which it will be shipped to Heatcraft for additional testing.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A novel defoamer for processing nuclear waste: Testing and performance

Abstract Legacy radioactive waste from nuclear weapons material processing is the biggest environmental challenge in the state of South Carolina, and one of the biggest in the United States. Although substantial progress has been made in processing and vitrifying high‐level radioactive waste at the Savannah River site, approximately 35 million gallons remains to be treated and dispositioned. In this article, we show the development of a new defoamer for use in the processing of high‐level radioactive waste. The application of the new defoamer is not only more effective at controlling foam but will shorten the batch processing time leading to safer and more efficient processing. This has the potential to help shorten the overall site mission lifetime, saving the federal government hundreds of millions of dollars. The novel aspect of the new defoamer is its effectiveness and stability in the harsh conditions needed for processing high‐level radioactive waste: high temperatures, pH 4–13, strong oxidizing and reducing agents, and numerous metal catalysts. The defoamer will replace an existing antifoam agent that decomposes to form multiple flammable gases. Because the existing antifoam agent decomposes quickly, processing changes increased processing time. Statement of novelty We demonstrate that a new defoamer has been developed for use in processing high‐level radioactive waste. This novel defoamer is effective and stable in the harsh processing conditions with no detectable flammable by‐products. Because the existing antifoam agent decomposes quickly, processing changes, including lowering acid addition rates and evaporation rates, increased processing time. The new defoamer is not only more effective at controlling foam but will shorten the batch processing time and lead to safer and more efficient processing by eliminating the production of flammable gases. Statement of industrial relevance Foaming is of great concern in many industrial processes involving three‐phase gas/liquid/fine‐solids systems, like in water evaporation, mineral floatation, air sparging in situ remediation techniques, and in those found in the paper industry.

Lambert, Dan P.↗

Dispersion Validation for Flow Involving a Large Structure

The atmospheric dispersion of contaminants in the wake of a large urban structure is a challenging fluid mechanics problem of interest to the scientific and engineering communities. Magnetic Resonance Velocimetry (MRV) is a relatively new technique that leverages diagnostic equipment used primarily by the medical field to make 3D engineering measurements of flow and contaminant dispersal. SIERRA/Fuego, a computational fluid dynamics (CFD) code at Sandia National Labs is employed to make detailed comparisons to the dataset to evaluate the quantitative and qualitative accuracy of the model. The comparison exercise shows good comparison between model and experimental results, with the wake region downstream of the tall building presenting the most significant challenge to the quantitative accuracy of the model. Model uncertainties are assessed through parametric variations. Some observations are made in relation to the future utility of MDV and CFD, and some productive follow-on activities are suggested that can help mature the science of flow modeling and experimental testing.

54 ENVIRONMENTAL SCIENCES↗

Interpretation of Colloid-Homologue Tracer Test 10-03, Including Comparisons to Test 10-01

This presentation covers the interpretations of colloid-homologue tracer test 10-03 conducted at the Grimsel Test Site, Switzerland, in 2010. It also provides a comparison of the interpreted test results with those of tracer test 10-01, which was conducted in the same fracture flow system and using the same tracers than test 10-03, but at a higher extraction flow rate. A method of correcting for apparent uranine degradation in test 10-03 is presented. Conclusions are: (1) Uranine degradation occurred in test 10-03, but not in 10-01; (2) Uranine correction based on apparent degradation rate in injection loop in test 11-02 seems reasonable when applied to data from test 10-03; (3) Colloid breakthrough curves quite similar in the two tests with similar recoveries relative to uranine (after correction); and (4) Much slower apparent desorption of homologues in test 10-03 than in 10-01 (any effect of residual homologues from test 10-01 in test 10-03?).

54 ENVIRONMENTAL SCIENCES↗

Anion exchange membrane test protocol validation

This study presents the validation of protocols for measuring ion exchange capacity (IEC) and alkaline stability of anion exchange membranes (AEMs) for low-temperature water electrolysis. While protocols are often tested within individual laboratories, their results across multiple laboratories with varying equipment, environmental conditions, and personnel qualification remain unverified. The validation involved Los Alamos National Laboratory (LANL), National Renewable Energy Laboratory (NREL), and University of Oregon (UO) using the same commercially available AEM to assess reproducibility and reliability of the protocols under diverse conditions. For the IEC protocol, results across laboratories were consistent within ±10% of the NMR-determined reference value. The alkaline stability protocol could pose greater challenges due to factors such as variations in sample collection timing, preservation methods, and analytical techniques, but consistent test results for percentage IEC loss were demonstrated across institutions. These results highlight the reliability and applicability of the protocols, emphasizing the importance of validation to ensure consistency in diverse research environments.

08 HYDROGEN↗

Transport Reactor Development Unit Modification to Provide a Syngas Slipstream at Elevated Conditions to Enable Separation of 100 LB/D of Hydrogen by Hydrogen Separation Membranes Year - 6 Activity 1.15 - Development of a National Center for Hydrogen Technology

Gasification of coal when associated with carbon dioxide capture and sequestration has the potential to provide low-cost as well as low-carbon hydrogen for electric power, fuels or chemicals production. The key element to the success of this concept is inexpensive, effective separation of hydrogen from carbon dioxide in synthesis gas. Many studies indicate that membrane technology is one of the most, if not the most, economical means of accomplishing separation; however, the advancement of hydrogen separation membrane technology is hampered by the absence of experience or demonstration that the technology is effective economically and environmentally at larger scales. While encouraging performance has been observed at bench scale (less than 12 lb/d hydrogen), it would be imprudent to pursue a largescale demonstration without testing at least one intermediate scale, such as 100 lb/d hydrogen. Among its many gasifiers, the Energy & Environmental Research Center is home to the transport reactor demonstration unit (TRDU), a unit capable of firing 200—500 lb/hr of coal to produce 400 scfm of synthesis gas containing more than 200 lb/d of hydrogen. The TRDU and associated downstream processing equipment has demonstrated the capability of producing a syngas over a wide range of temperatures and contaminant levels — some of which approximate conditions of commercial-scale gasifiers. Until this activity, however, the maximum pressure of the TRDU’ s product syngas was 120 psig, well below the 400+ psig pressures of existing large gasifiers. This activity installed a high-temperature compressor capable of accepting the range of TRDU products up to 450°F and compressing them to 500 psig, a pressure comparable to some large scale gasifiers. Thus, with heating or cooling downstream of the TRDU compressor, the unit is now able to present a near-raw to clean gasifier synthesis gas containing more than 100 lb/d of hydrogen at up to 500 psig over a wide range of temperatures to hydrogen separation membranes or other equipment for development and demonstration.

01 COAL, LIGNITE, AND PEAT↗

Performance Testing of Tracer Gas and Tracer Aerosol Detectors for use in Radionuclide NESHAP Compliance Testing

The Rad-NESHAP program, part of the Air Quality Compliance team of LANL’s Compliance Programs group (EPC-CP), and the Radiation Instrumentation & Calibration team, part of the Radiation Protection Services group (RP-SVS), frequently partner on issues relating to characterizing air flow streams. This memo documents the most recent example of this partnership, involving performance testing of sulfur hexafluoride detectors for use in stack gas mixing tests. Additionally, members of the Rad-NESHAP program performed a functional trending test on a pair of optical particle counters, comparing results from a non-calibrated instrument to a calibrated instrument. Prior to commissioning a new stack sampling system, the ANSI Standard for stack sampling requires that the stack sample location must meet several criteria, including uniformity of tracer gas and aerosol mixing in the air stream. For these mix tests, tracer media (sulfur hexafluoride gas or liquid oil aerosol particles) are injected into the stack air stream and the resulting air concentrations are measured across the plane of the stack at the proposed sampling location. The coefficient of variation of these media concentrations must be under 20% when evaluated over the central 2/3 area of the stack or duct. The instruments which measure these air concentrations must be tested prior to the stack tests in order to ensure their linear response to varying air concentrations of either tracer gas or tracer aerosol. The instruments used in tracer gas and aerosol mix testing cannot be calibrated by the LANL Standards and Calibration Laboratory, so they would normally be sent off-site for factory calibration by the vendor. Operational requirements can prevent formal factory calibration of some instruments after they have been used in hazardous settings, e.g., within a radiological facility with potential airborne contamination. The performance tests described in this document are intended to demonstrate the reliable performance of the test instruments for the specific tests used in stack flow characterization.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗