Search NASA⌕ Search

SEARCH · Search NASA

Results for “Field Study”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,009 records · Page 56

Demand controlled ventilation and classroom ventilation

This document summarizes a research effort on demand controlled ventilation and classroom ventilation. The research on demand controlled ventilation included field studies and building energy modeling.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Characterization of Energy Savings and Thermal Comfort Improvements Derived from Using Interior Storm Windows

This field study of a single historic home in Seattle, WA documents the performance of Indow ® Windows’s interior storm window inserts. Energy use and the temperature profile of the house were monitored before and after the installation of the window inserts and changes in the two recorded metrics were examined. Using the defined analysis approach, it was determined that the interior storm windows produced a 22% reduction of the HVAC energy bill and had an undetermined effect on the thermal comfort in the house. Although there was no measurable changes in the thermal comfort of the house, the occupant noted the house to be “warmer in the winter and cooler in the summer” and that the “temperatures are more even (throughout the house).” The interior storm windows were found to be not cost effective, largely due to the retrofits completed on its heating system. However, if the economic analysis was conducted based on the old heating system, a 72% efficient oil fired furnace, the Indow Windows proved to be economical and had a simple payback period of 9.0 years.

high performance housing↗

Moisture Risk in Unvented Attics Due to Air Leakage Paths

IBACOS completed an initial analysis of moisture damage potential in an unvented attic insulated with closed-cell spray polyurethane foam. To complete this analysis, the research team collected field data, used computational fluid dynamics to quantify the airflow rates through individual airflow (crack) paths, simulated hourly flow rates through the leakage paths with CONTAM software, correlated the CONTAM flow rates with indoor humidity ratios from Building Energy Optimization software, and used Warme und Feuchte instationar Pro two-dimensional modeling to determine the moisture content of the building materials surrounding the cracks. Given the number of simplifying assumptions and numerical models associated with this analysis, the results indicate that localized damage due to high moisture content of the roof sheathing is possible under very low airflow rates. Reducing the number of assumptions and approximations through field studies and laboratory experiments would be valuable to understand the real-world moisture damage potential in unvented attics.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Demand Controlled Ventilation and Classroom Ventilation

This document summarizes a research effort on demand controlled ventilation and classroom ventilation. The research on demand controlled ventilation included field studies and building energy modeling.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Field Evaluation of the Restorative Capacity of the Aquifer Downgradient of a Uranium In-Situ Recovery Mining Site (Rev. 1)

A two-part field study was conducted in Smith Ranch-Highland in-situ recovery (ISR) near Douglas, Wyoming, to evaluate the restorative capacity of the aquifer downgradient (i.e., hydrologically downstream) of a Uranium ISR mining site with respect to the transport of uranium and other potential contaminants in groundwater after mining has ceased. The study was partially conducted by checking the Uranium content and the alkalinity of separate wells, some wells had been restored and others had not. A map and in-depth procedures of the study are included.

54 ENVIRONMENTAL SCIENCES↗

Characteristics and Performance of Existing Load Disaggregation Technologies

Non-intrusive load monitoring (NILM) or non-intrusive appliance load monitoring (NIALM) is an analytic approach to disaggregate building loads based on a single metering point. This advanced load monitoring and disaggregation technique has the potential to provide an alternative solution to high-priced traditional sub-metering and enable innovative approaches for energy conservation, energy efficiency, and demand response. However, since the inception of the concept in the 1980’s, evaluations of these technologies have focused on reporting performance accuracy without investigating sources of inaccuracies or fully understanding and articulating the meaning of the metrics used to quantify performance. As a result, the market for, as well as, advances in these technologies have been slowly maturing. To improve the market for these NILM technologies, there has to be confidence that the deployment will lead to benefits. In reality, every end-user and application that this technology may enable does not require the highest levels of performance accuracy to produce benefits. Also, there are other important characteristics that need to be considered, which may affect the appeal of NILM products to certain market targets (i.e. residential and commercial building consumers) and the suitability for particular applications. These characteristics include the following: 1) ease of use, the level of expertise/bandwidth required to properly use the product; 2) ease of installation, the level of expertise required to install along with hardware needs that impact product cost; and 3) ability to inform decisions and actions, whether the energy outputs received by end-users (e.g. third party applications, residential users, building operators, etc.) empower decisions and actions to be taken at time frames required for certain applications. Therefore, stakeholders, researchers, and other interested parties should be kept abreast of the evolving capabilities, uses, and characteristics of NILM that make them attractive for certain building environments and different classes of end-users. The intent of this report is to raise awareness of trending NILM approaches. Additionally, three existing technologies were acquired and evaluated using the Residential Building Stock Assessment (RBSA) owner-occupied test bed operated by the Northwest Energy Efficiency Alliance (NEEA) to understand performance accuracy of current NILM products under realistic conditions. Based on this field study experience, the characteristics exhibited by the NILM products included in the assessment are also discussed in this report in terms of ease of use, ease of installation, ability to inform decisions and actions. Results of the analysis performed to investigate the accuracy of the participating NILM products in estimating energy use of individual appliances are also presented.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Moisture Risk in Unvented Attics Due to Air Leakage Paths

IBACOS completed an initial analysis of moisture damage potential in an unvented attic insulated with closed-cell spray polyurethane foam. To complete this analysis, the research team collected field data, used computational fluid dynamics to quantify the airflow rates through individual airflow (crack) paths, simulated hourly flow rates through the leakage paths with CONTAM software, correlated the CONTAM flow rates with indoor humidity ratios from Building Energy Optimization software, and used Wärme und Feuchte instationär Pro two-dimensional modeling to determine the moisture content of the building materials surrounding the cracks. Given the number of simplifying assumptions and numerical models associated with this analysis, the results indicate that localized damage due to high moisture content of the roof sheathing is possible under very low airflow rates. Reducing the number of assumptions and approximations through field studies and laboratory experiments would be valuable to understand the real-world moisture damage potential in unvented attics.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Weatherization and Indoor Air Quality: Measured Impacts in Single Family Homes Under the Weatherization Assistance Program

This report summarizes findings from a national field study of indoor air quality parameters in homes treated under the Weatherization Assistance Program (WAP). The study involved testing and monitoring in 514 single-family homes (including mobile homes) located in 35 states and served by 88 local weatherization agencies.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Ultra Low Sulfur Home Heating Oil Demonstration Project

This Ultra Low Sulfur (ULS) Home Heating Oil Demonstration Project was funded by the New York State Energy Research and Development Authority (NYSERDA) and has successfully quantified the environmental and economic benefits of switching to ULS (15 PPM sulfur) heating oil. It advances a prior field study of Low Sulfur (500 ppm sulfur) heating oil funded by NYSERDA and laboratory research conducted by Brookhaven National Laboratory (BNL) and Canadian researchers. The sulfur oxide and particulate matter (PM) emissions are greatly reduced as are boiler cleaning costs through extending cleaning intervals. Both the sulfur oxide and PM emission rates are directly related to the fuel oil sulfur content. The sulfur oxide and PM emission rates approach near-zero levels by switching heating equipment to ULS fuel oil, and these emissions become comparable to heating equipment fired by natural gas. This demonstration project included an in-depth review and analysis of service records for both the ULS and control groups to determine any difference in the service needs for the two groups. The detailed service records for both groups were collected and analyzed and the results were entered into two spreadsheets that enabled a quantitative side-by-side comparison of equipment service for the entire duration of the ULS test project. The service frequency for the ULS and control group were very similar and did indicate increased service frequency for the ULS group. In fact, the service frequency with the ULS group was slightly less (7.5 percent) than the control group. The only exception was that three burner fuel pump required replacement for the ULS group and none were required for the control group.

02 PETROLEUM↗

U.S. Department of Energy Portsmouth Annual Site Environmental Report (ASER) for 2012. Student Summary

The report that follows is a summary of the U.S. Department of Energy Portsmouth Annual Site Environmental Report for 2012 (ASER), regarding PORTS located near Piketon, Ohio. The summary has been compiled by the 2015 WHS Environmental Science class, made up of juniors and seniors at WHS during the 2014-2015 school year. Even with most of the class having lived in this region for their entire lives, it became apparent how little of the workings of the plant were known by the members of the class. In the process of putting this summary together, we were able to gain a better understanding of the history, function, and possible future of the site. The presentations provided by Ohio University, Fluor-B&W Portsmouth LLC (FBP), U.S. DOE, and Rio Grande University were greatly appreciated and provided invaluable understanding of the materials which we were asked to summarize. Not only did we learn from the presentations, but we greatly enjoyed the opportunities to participate in the field studies that gave us a glimpse into what is being done at the plant site to ensure the environmental safety of people and wildlife of this region. Our goal from this summary has been to make the information concerning the monitoring and cleanup of the PORTS facility better understood by the people who it most affects. We hope that this summary makes the information useful to you and that you can gain a better understanding of the cleanup processes that are going on around the site to ensure your safety. Though it has been hard work, we appreciate the opportunity that we have been presented with to learn and share with the people of our community.

54 ENVIRONMENTAL SCIENCES↗

Field Demonstration of Ground-Source Integrated Heat Pump Part I. Technology and Field Demo System/Site Descriptions, and Preliminary Summer/Fall Performance Analysis for One Site

The field study is planned to continue through the 2016 cooling season with the draft final project report due by September 30, 2016. This report provides a description of both installations and preliminary 2015 cooling and fall season performance results for the Knoxville site. For the August 18 through December 14 period, the Knoxville site GS-IHP provided 53.6% total source energy savings compared to a baseline electric RTU/heat pump and electric WH. Peak demand savings ranged from 33% to 59% per month. Energy cost savings of 53.1% have been achieved to date with more than half of that coming from reduced demand charges. Data on installation and maintenance costs are being collected and will be combined with total test period energy savings data for a payback analysis to be included in the project final report. The GS-IHP also saved a significant amount of carbon emissions. The total emission savings for the Knoxville site for the August-December 2015 period were ~0.8 metric tons. If trading for carbon credits ever becomes a reality, additional cost savings would be realized.

20 FOSSIL-FUELED POWER PLANTS↗

Construction Guidelines for High R-Value Walls without Exterior Rigid Insulation

High-R wall assemblies (R-40 and above) are gaining popularity in the market due to programs like the DOE's Zero Energy Ready Home program, Passive House (PH), Net Zero Energy Home (NZEH) challenges in several states, and highly incentivized retrofit programs. In response to this demand, several builders have successfully used 'double wall' systems to more practically achieve higher R-values in thicker, framed walls. To builders of conventional stick-framed homes, often one of the most appealing features of double wall systems is that there are very few new exterior details. Exterior sheathing, structural bracing, house wrap or building paper, window and door flashing, and siding attachment are usually identical to good details in conventional framed wall systems. The information presented in this guide is intended to reduce the risk of failure in these types of assemblies, increase durability, and result in a reduction of material brought to landfills due to failures and resulting decay. While this document focuses on double wall framing techniques, the majority of the information on how to properly construct and finish high R-value assemblies is applicable to all wall assemblies that do not have foam insulation installed on the exterior of the structural sheathing. The techniques presented have been shown through field studies to reduce the likelihood of mold growth and moisture related damage and are intended for builders, framing contractors, architects, and consultants involved in designing and building super insulated homes.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Use of Cultivation Data from the Algae Testbed Public Private Partnership as Utilized in NREL's Algae State of Technology Assessments

The Algae Testbed Public Private Partnership (ATP3) conducted algal growth experiments over the course of 16 months termed the Unified Field Studies (UFS). These experiments were conducted at 5 different geographic locations in Arizona (ASU), California (CP), Florida (FA), Georgia (GT), and Hawaii (CELL). The UFS sought to evaluate different algal biomass harvesting strategies using identical ponds, media, and operational conditions through all four seasons across different geographic regions to isolate the effects on productivity attributed to locational climate and seasonal variability, overlaid by the differing harvest strategies. Set up as the baseline against which other experiments would build upon, it must be emphasized that as per the stated, approved experimental goals of the ATP3 UFS, no attempts at growth or lipid accumulation optimization were made; rather, the primary focus of the UFS work was to cultivate algal biomass under deliberate, consistent conditions, time periods, and harvesting protocols, to provide public data on year-round outdoor biomass production that could be directly compared between one site and another (with accompanying climate data for each site). Thus the resulting productivity numbers in effect represent a conservative baseline of non-optimized algal growth one may expect at these sites. Also clearly weather can vary dramatically from season to season and from year to year, and even within a given 'season' where an individual season's data was typically based on 4-6 week operating windows. Thus these numbers also only reflect a short snapshot in time, and must be interpreted carefully in projecting what may be expected over many years or decades (for example, a 30-year facility lifetime as evaluated in techno-economic models).

09 BIOMASS FUELS↗

Healthy Efficient New Gas Homes (HENGH) Pilot Test Results

The Healthy Efficient New Gas Homes (HENGH) is a field study that will collect data on ventilation systems and indoor air quality (IAQ) in new California homes that were built to 2008 Title 24 standards. A pilot test was performed to help inform the most time and cost effective approaches to measuring IAQ in the 100 test homes that will be recruited for this study. Two occupied, single-family detached homes built to 2008 Title 24 participated in the pilot test. One of the test homes uses exhaust-only ventilation provided by a continuous exhaust fan in the laundry room. The other home uses supply air for ventilation. Measurements of IAQ were collected for two weeks. Time-resolved concentrations of particulate matter (PM), nitrogen dioxide (NO2), carbon dioxide (CO2), carbon monoxide (CO), and formaldehyde were measured. Measurements of IAQ also included time-integrated concentrations of volatile organic compounds (VOCs), volatile aldehydes, and NO2. Three perfluorocarbon tracers (PFTs) were used to estimate the dilution rate of an indoor emitted air contaminant in the two pilot test homes. Diagnostic tests were performed to measure envelope air leakage, duct leakage, and airflow of range hood, exhaust fans, and clothes dryer vent when accessible. Occupant activities, such as cooking, use of range hood and exhaust fans, were monitored using various data loggers. This document describes results of the pilot test.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Long-Term Evaluation of SSL Field Performance in Select Interior Projects

This GATEWAY project evaluated four field installations to better understand the long-term performance of a number of LED products, which can hopefully stimulate improvements in designing, manufacturing, specifying, procuring, and installing LED products. Field studies provide the opportunity to discover and investigate issues that cannot be simulated or uncovered in a laboratory, but the installed performance over time of commercially available LED products has not been well documented. Improving long-term performance can provide both direct energy savings by reducing the need to over-light to account for light loss and indirect energy savings through better market penetration due to SSL’s competitive advantages over less-efficient light source technologies. The projects evaluated for this report illustrate that SSL use is often motivated by advantages other than energy savings, including maintenance savings, easier integration with control systems, and improved lighting quality.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Summer Indoor Heat Pump Water Heater Evaluation in a Hot-Dry Climate

Heat pump water heaters offer a significant opportunity to improve water heating performance for the over 40% of U.S. households that heat domestic hot water using electric resistance storage water heaters. Numerous field studies have also been completed documenting performance in a variety of climates and applications. More recent evaluation efforts have focused attention on the performance of May through September 2014, with ongoing winter monitoring being sponsored by California utility partners. Summer results show favorable system performance with extrapolated annual water heating savings of 1,466 to 2,300 kWh per year, based on the observed hot water loads. Additional summer space cooling benefits savings of 121 to 135 kWh per year were projected, further increasing the water energy savings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Summer Indoor Heat Pump Water Heater Evaluation in a Hot-Dry Climate

Heat pump water heaters offer a significant opportunity to improve water heating performance for the over 40% of U.S. households that heat domestic hot water using electric resistance storage water heaters. Numerous field studies have also been completed documenting performance in a variety of climates and applications. More recent evaluation efforts have focused attention on the performance of May through September 2014, with ongoing winter monitoring being sponsored by California utility partners. Summer results show favorable system performance with extrapolated annual water heating savings of 1,466 to 2,300 kWh per year, based on the observed hot water loads. Additional summer space cooling benefits savings of 121 to 135 kWh per year were projected, further increasing the water energy savings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Annual Status Report (FY2016) Performance Assessment for the Environmental Restoration Disposal Facility

DOE O 435.1, Radioactive Waste Management, and DOE M 435.1-1, Radioactive Waste Management Manual, require that a determination of continued adequacy of the performance assessment (PA), composite analysis (CA), and disposal authorization statement (DAS) be made on an annual basis, and it must consider the results of data collection and analysis from research, field studies, and monitoring. Annual summaries of low-level waste (LLW) disposal operations must be prepared with respect to the conclusions and recommendations of the PA and CA, and a determination of the need to revise the PA or CA must be made. The annual summary requirement provides a structured approach for demonstrating the continued adequacy of the PA and CA in demonstrating a reasonable expectation that the performance objectives will be met. This annual summary addresses only the status of the Environmental Restoration Disposal Facility (ERDF) PA (CP-60089, Performance Assessment for the Environmental Restoration Disposal Facility, Hanford Site, Washington, formerly WCH-520 Rev. 1)1. The CA for ERDF is supported by DOE/RL-2016-62, Annual Status Report (FY 2016): Composite Analysis of Low Level Waste Disposal in the Central Plateau at the Hanford Site. The ERDF PA portion of the CA document is found in Section 3.1.4, and the ERDF operations portion is found in Section 3.3.3.2 of that document.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗