Search NASA⌕ Search

SEARCH · Search NASA

Results for “Filtering techniques”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,009 records · Page 56

A Novel Modeling Framework for Computationally Efficient and Accurate Real-Time Ensemble Flood Forecasting With Uncertainty Quantification

A novel modeling framework that simultaneously improves accuracy, predictability, and computational efficiency is presented. It embraces the benefits of three modeling techniques integrated together for the first time: surrogate modeling, parameter inference, and data assimilation. The use of polynomial chaos expansion (PCE) surrogates significantly decreases computational time. Parameter inference allows for model faster convergence, reduced uncertainty, and superior accuracy of simulated results. Ensemble Kalman filters assimilate errors that occur during forecasting. To examine the applicability and effectiveness of the integrated framework, we developed 18 approaches according to how surrogate models are constructed, what type of parameter distributions are used as model inputs, and whether model parameters are updated during the data assimilation procedure. We conclude that (1) PCE must be built over various forcing and flow conditions, and in contrast to previous studies, it does not need to be rebuilt at each time step; (2) model parameter specification that relies on constrained, posterior information of parameters (so-called Selected specification) can significantly improve forecasting performance and reduce uncertainty bounds compared to Random specification using prior information of parameters; and (3) no substantial differences in results exist between single and dual ensemble Kalman filters, but the latter better simulates flood peaks. The use of PCE effectively compensates for the computational load added by the parameter inference and data assimilation (up to ~80 times faster). Therefore, the presented approach contributes to a shift in modeling paradigm arguing that complex, high-fidelity hydrologic and hydraulic models should be increasingly adopted for real-time and ensemble flood forecasting.

54 ENVIRONMENTAL SCIENCES↗

White luminescence from silica glass containing red/green/blue luminescent nanocrystalline silicon particles

Silica glasses containing blue/green/red luminescent nanocrystalline silicon (nc-Si) particles that consist of monolayer and/or three-layer structures were fabricated by a radio-frequency sputtering technique and postannealing treatment. These silica glasses showed very broad luminescence spectra with a peak at 460 nm (blue light), 550 nm (green light), and 800 nm (red light). When these samples were irradiated by using a xenon lamp with an optical bandpass filter of 313 nm, the luminescence colors from these silica glasses were a white light. The white luminescence of the sample with the three-layer structure exhibited the high luminance value of 1.5 cd/m{sup 2}. This value was ascribed to the adjustment of sizes and densities of blue/green/red luminescent nc-Si particles, and the lowering of densities of P{sub b} centers (nonradiative recombination centers) at the nc-Si particle/silica glass interface layer.

36 MATERIALS SCIENCE↗

Two-color planar laser-induced fluorescence thermometry in aqueous solutions

We demonstrate a two-color planar laser-induced fluorescence technique for obtaining two-dimensional temperature images in water. For this method, a pulsed Nd:YAG laser at 532 nm excites a solution of temperature-sensitive rhodamine 560 and temperature-insensitive sulforhodamine 640. The resulting emissions are optically separated through filters and detected via a charged-couple device (CCD) camera system. A ratio of the two images yields temperature images independent of incident irradiance. An uncertainty in temperature of {+-}1.4 deg. C is established at the 95% confidence interval.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Compendium of Completed Testing in Support of Rotary Microfiltration at Savannah River Site and Hanford

This report presents a chronological summary of previous technology development efforts concerning the rotary microfiltration (RMF) unit from SpinTek™. Rotary microfiltration has been developed for high radiation application over the last decades as one of the optional filtration techniques for supplemental treatment. Supplemental treatment includes a near- or in-tank solids separation and subsequent cesium removal unit, followed by an immobilization technique; this includes options such as steam reforming, bulk vitrification or cast stone (grout). The main difference between RMF and standard cross flow filtration (CFF) is the disconnection of filtrate flux from feed velocity; i.e., filtrate flux is only dependent on transmembrane pressure, filter fouling and temperature. These efforts have been supported by the U.S. Department of Energy (DOE), Office of Cleanup Technologies since the 1990s by their Environmental Management Program (currently EM-31). In order to appropriately address future testing needs, a compilation of the relevant previous testing reports was essential. This compendium does not intend to cover all of the presentations/reports that were produced over the last decades but focuses on those of relevance for developing an RMF unit fit for deployment at the Hanford site. The report is split into three parts: (1) an introductory overview, (2) Figure 1 graphically covering the main development steps and its key players and (3) a more detailed table of the citations and brief descriptions of results and recommendations.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The 2.4 μ m Galaxy Luminosity Function as Measured Using WISE . II. Sample Selection

The WISE satellite surveyed the entire sky multiple times in four infrared (IR) wavelengths (3.4, 4.6, 12, and 22 $μ$m). This all-sky IR photometric survey makes it possible to leverage many of the large publicly available spectroscopic redshift surveys to measure galaxy properties in the IR. While characterizing the cross-matching of WISE data to a single survey is a straightforward process, doing it with six different redshift surveys takes a fair amount of space to characterize adequately, because each survey has unique caveats and characteristics that need addressing. This work describes a data set that results from matching five public redshift surveys with the AllWISE data release, along with a reanalysis of the data described in Lake et al. The combined data set has an additional flux limit of 80 $μ$Jy (19.14 AB mag) in WISE's W1 filter, imposed in order to limit it to targets with high completeness and reliable photometry in the AllWISE data set. Consistent analysis of all of the data is only possible if the color bias discussed in Ilbert et al. is addressed (e.g., the techniques explored in Lake et al.). Finally, the sample defined herein is used in a companion paper in this series to measure the luminosity function of galaxies at 2.4 μm rest-frame wavelength, and the selection process of the sample is optimized for this purpose.

79 ASTRONOMY AND ASTROPHYSICS↗

Progression of soot cake layer properties during the systematic regeneration of diesel particulate filters measured with neutron tomography

Although particulate filters (PFs) have been a key component of the emission control system for modern diesel engines, there remain significant questions about the basic regeneration behavior of the filters and how it changes with accumulation of increasing soot layers. This effort describes a systematic deposition and regeneration of particulate matter in 25-mm diameter × 76-mm long wall-flow PFs composed of silicon carbide (SiC) material. The initial soot distributions were analyzed for soot cake thickness using a nondestructive neutron imaging technique. With the PFs intact, it was then possible to sequentially regenerate the samples and reanalyze them, which was performed after nominal 20, 50, and 70 % regenerations. The loaded samples show a relatively uniform distribution of particulate with an increasing soot cake thickness and nearly identical initial density of 70 mg/cm 3 . Throughout regeneration, the soot cake thickness initially decreases significantly while the density increases to 80–90 mg/cm 3 . After ~50 % regeneration, the soot cake thickness stays relatively constant, but instead, the density decreases as pores open up in the layer (~35 mg/cm 3 at 70 % regeneration). Here, complete regeneration initially occurs at the rear of the PF channels. With this information, a conceptual model of the regeneration is proposed.

54 ENVIRONMENTAL SCIENCES↗

Learning Spectral Templates for Photometric Redshift Estimation from Broadband Photometry

Estimating redshifts from broadband photometry is often limited by how accurately we can map the colors of galaxies to an underlying spectral template. Current techniques utilize spectrophotometric samples of galaxies or spectra derived from spectral synthesis models. Both of these approaches have their limitations: either the sample sizes are small and often not representative of the diversity of galaxy colors, or the model colors can be biased (often as a function of wavelength), which introduces systematics in the derived redshifts. In this paper, we learn the underlying spectral energy distributions from an ensemble of ∼100 K galaxies with measured redshifts and colors. We show that we are able to reconstruct emission and absorption lines at a significantly higher resolution than the broadband filters used to measure the photometry for a sample of 20 spectral templates. We find that our training algorithm reduces the fraction of outliers in the derived photometric redshifts by up to 28%, bias up to 91%, and scatter up to 25%, when compared to estimates using a standard set of spectral templates. We discuss the current limitations of this approach and its applicability for recovering the underlying properties of galaxies. Our derived templates and the code used to produce these results are publicly available in a dedicated Github repository: https://github.com/dirac-institute/photoz-template-learning.

79 ASTRONOMY AND ASTROPHYSICS↗

Status and characterization of the lithium beam diagnostic on DIII-D

The 30 keV lithium beam diagnostic on DIII-D is suitable to measure both the radial electron density and poloidal magnetic field profiles in the pedestal. The refurbished system features a new setup to measure the Doppler shift allowing accurate alignment of the spectral filters. The injector has been optimized to generate a stable lithium neutral beam with a current of I= 15−20 mA and a diameter of 1.9 ± 0.1 cm measured by beam imaging. The typical temporal resolution is Δt= 1−10 ms and the radial resolution of ΔR= 5 mm is given by the optical setup. A new analysis technique based on fast Fourier transform avoids systematic error contributions from the digital lock-in analysis and accounts intrinsically for background light correction. Latest upgrades and a detailed characterization of the system are presented. Proof-of-principle measurements of the poloidal magnetic field with a statistical error of typically 2% show a fair agreement with the predictions modeled with the Grad-Shafranov equilibrium solver EFIT within 4%.

43 PARTICLE ACCELERATORS↗

The effect of relative humidity on eddy covariance latent heat flux measurements and its implication for partitioning into transpiration and evaporation

While the eddy covariance (EC) technique is a well-established method for measuring water fluxes (i.e., evaporation or 'evapotranspiration’, ET), the measurement is susceptible to many uncertainties. One such issue is the potential underestimation of ET when relative humidity (RH) is high (> 70%), due to low-pass filtering with some EC systems. Yet, this underestimation for different types of EC systems (e.g. open-path or closed-path sensors) has not been characterized for synthesis datasets such as the widely used FLUXNET2015 dataset. Here, we assess the RH-associated underestimation of latent heat fluxes (LE, or ET) from different EC systems for 163 sites in the FLUXNET2015 dataset. We found that the LE underestimation is most apparent during hours when RH is higher than 70%, predominantly observed at sites using closed-path EC systems, but the extent of the LE underestimation is highly site-specific. We then propose a machine learning based method to correct for this underestimation, and compare it to two energy balance closure based LE correction approaches (Bowen ratio correction, BRC, and attributing all errors to LE). Our correction increases LE by 189% for closed-path sites at high RH (> 90%), while BRC increases LE by around 30% for all RH conditions. Additionally, we assess the influence of these corrections on ET-based transpiration (T) estimates using two different ET partitioning methods. Results show opposite responses (increasing vs. slightly decreasing T-to-ET ratios, T/ET) between the two methods when comparing T based on corrected and uncorrected LE. Overall, our results demonstrate the existence of a high RH bias in water fluxes in the FLUXNET2015 dataset and suggest that this bias is a pronounced source of uncertainty in ET measurements to be considered when estimating ecosystem T/ET and WUE.

54 ENVIRONMENTAL SCIENCES↗

Room-temperature MBE deposition, thermoelectric properties, and advanced structural characterization of binary Bi[subscript 2]Te[subscript 3] and Sb[subscript 2]Te[subscript 3] thin films

Sb{sub 2}Te{sub 3} and Bi{sub 2}Te{sub 3} thin films were grown at room temperature on SiO{sub 2} and BaF{sub 2} substrates using molecular beam epitaxy. A layer-by-layer growth was achieved such that metallic layers of the elements with 0.2 nm thickness were deposited. The layer structure in the as-deposited films was confirmed by X-ray diffraction and was seen more clearly in Sb{sub 2}Te{sub 3} thin films. Subsequent annealing was done at 250 C for 2 h and produced the Sb{sub 2}Te{sub 3} and Bi{sub 2}Te{sub 3} crystal structure as confirmed by high-energy X-ray diffraction. This preparation process is referred to as nano-alloying and it was demonstrated to yield single-phase thin films of these compounds. In the thin films a significant texture could be identified with the crystal c axis being almost parallel to the growth direction for Sb{sub 2}Te{sub 3} and tilted by about 30{sup o} for Bi{sub 2}Te{sub 3} thin films. In-plane transport properties were measured for the annealed films at room temperature. Both films yielded a charge carrier density of about 2.6 x 10{sup 19} cm{sup -3}. The Sb{sub 2}Te{sub 3} films were p-type, had a thermopower of +130 {micro}V K{sup -1}, and surprisingly high mobilities of 402 cm{sup 2} V{sup -1} s{sup -1}. The Bi{sub 2}Te{sub 3} films were n-type, showed a thermopower of -153 {micro}V K{sup -1}, and yielded significantly smaller mobilities of 80 cm2 V{sup -1} s{sup -1}. The chemical composition and microstructure of the films were investigated by transmission electron microscopy (TEM) on cross sections of the thin films. The grain sizes were about 500 nm for the Sb{sub 2}Te{sub 3} and 250 nm for the Bi{sub 2}Te{sub 3} films. In the Bi{sub 2}Te{sub 3} thin film, energy-filtered TEM allowed to image a Bi-rich grain boundary phase, several nanometers thick. This secondary phase explains the poor mobilities of the Bi{sub 2}Te{sub 3} thin film. With these results the high potential of the nano-alloying deposition technique for growing films with a more complex layer architecture is demonstrated.

36 MATERIALS SCIENCE↗

PRECISE THROUGHPUT DETERMINATION OF THE PanSTARRS TELESCOPE AND THE GIGAPIXEL IMAGER USING A CALIBRATED SILICON PHOTODIODE AND A TUNABLE LASER: INITIAL RESULTS

We have used a precision-calibrated photodiode as the fundamental metrology reference in order to determine the relative throughput of the PanSTARRS telescope and the Gigapixel imager, from 400 nm to 1050 nm. Our technique uses a tunable laser as a source of illumination on a transmissive flat-field screen. We determine the full-aperture system throughput as a function of wavelength, including (in a single integral measurement) the mirror reflectivity, the transmission functions of the filters and the corrector optics, and the detector quantum efficiency, by comparing the light seen by each pixel in the CCD array to that measured by a precision-calibrated silicon photodiode. This method allows us to determine the relative throughput of the entire system as a function of wavelength, for each pixel in the instrument, without observations of celestial standards. We present promising initial results from this characterization of the PanSTARRS system, and we use synthetic photometry to assess the photometric perturbations due to throughput variation across the field of view.

79 ASTRONOMY AND ASTROPHYSICS↗

Optical noise in a free-space quantum communications link from natural and nuclear disturbed environments*

Satellite communications at radio frequencies can experience a ‘blackout’ period following the atmospheric detonation of a nuclear weapon. The wavelengths used for free-space quantum communications will not incur the same ‘blackout’ effects from a nuclear detonation, but the optical systems will suffer from a phenomenon called redout. Redout occurs in an optical detector when ambient light scatters into the optical receiver, causing elevated background photon counts in the detector such that background noise overwhelms the signal. In this work, the duration of the redout effect is quantified from a nuclear disturbed environment on a ground-to-space quantum optical link. In addition, we comment on various techniques for reducing ambient and nuclear disturbed background counts in a quantum free-space optical link. For low-altitude nuclear detonations (i.e., under 50 km), the maximum interference time will be less than 1 min. Implementing a telescope, timing gate, and wavelength filter to the detector can reduce the background counts in the detector significantly. Aerosol levels and ground albedo are major contributors to background noise in a ground-to-satellite quantum channel, and ground station location should factor in both variables.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Quality Assessment of GPU Power Profiling Mechanisms

Accurate component-level power measurements are nowadays essential for the design and optimization of high-performance computing (HPC) systems and applications. Particularly, as more and more heterogeneous HPC systems are developed, the characterizations of GPU power profiles have become extremely crucial because, although GPUs provide exceptional performance, they do consume substantial amounts of power. Currently, there are various GPU power profiling mechanisms available; however, there is no standard way to assess the quality of such profiling schemes. To address this issue, in this paper, we develop an assessment methodology to rate the quality and performance of the profiling mechanism itself. Specifically, we present the assessments of four different GPU power profiling techniques: (i) Nvidia's NVML via Allinea MAP, (ii) Nvidia's NVML via direct reads, and (iii) Penguin Computing's PowerInsight (PI) via two vendor-provided drivers, and (iv) PowerInsight via Allinea MAP. In addition, we discuss the effects of moving-average filters to explain the slow variations of some of the measured power profiles. Based on our assessment, the GPU power profiling mechanism using PI device outperforms the other schemes by reliably measuring the ground-truth power profile generated by a GPU stress-test benchmark.

Sen, Satyabrata↗

WE-A-12A-01: Medical Physics 1.0 to 2.0, Session 2: Radiography, Mammography and Fluoroscopy

Medical Physics 2.0 is a bold vision for an existential transition of clinical imaging physics in face of the new realities of value-based and evidencebased medicine, comparative effectiveness, and meaningful use. It speaks to how clinical imaging physics can expand beyond traditional insular models of inspection and acceptance testing, oriented toward compliance, towards team-based models of operational engagement, prospective definition and assurance of effective use, and retrospective evaluation of clinical performance. Organized into four sessions of the AAPM, this particular session focuses on three specific modalities as outlined below. Radiography 2.0: The development of electronic capture in recent years has changed the landscape and spurred reinvestment by healthcare providers. The radiography presentation will explore how the diagnostic medical physicist must adapt to these changes to support radiographic imaging, and how she/he can add value in radiography practice over the next 5-10 years. Topics of discussion include new metrology of evaluation, new models of clinical engagement, and effective integration of new technologies. Mammography 2.0: Mammography has been an interesting testing ground on the effectiveness of close involvement of medical physicists with equipment in the past twenty years. The outcomes have clearly shown major improvements in image quality and significant reduction in the average glandular dose. However, the medical physicist's role in mammography has been largely focused to annual surveys and with limited input on operational issues with image artifacts, optimal mammographic acquisition mode and problems with image quality. This mammography presentation will address why and how medical physicists must be prepared to address the new models of practice that include new metrics of performance and the integration of new technologies (DBT, syncretized mammograms, contrast mammography, breast CT) into clinical practice. Fluoroscopy 2.0: Physics support of fluoroscopy should be operationally as opposed to compliance focused. Testing protocols must address new hardware, acquisition methods, and image processing. Future available tools are discussed. Proper configuration of acquisition parameters (focal spot size, voltage and added filter, tube current, pulse width, pulse rate, scatter removal) as a function of patient size from the neonate to bariatric patient is key to providing diagnostic image quality at properly managed radiation doses. Learning Objectives: Appreciate the limitations of the currently available tools and techniques in clinical medical physics in radiography, mammography, and fluoroscopy, and ways to improve upon current deficiencies. Appreciate the changing environment of imaging practice and the need for the medical physicist to be an expert consultant and educator in a capacity that extends beyond the annual survey of equipment. Understand the status of the rapidly changing environment in breast imaging from planar imaging to tomosynthesis and possibly to breast CT. Identify appropriate configuration of acquisition parameters as a function of patient size to manage radiation dose and ensure diagnostic image quality.

60 APPLIED LIFE SCIENCES↗

Estimating pediatric entrance skin dose from digital radiography examination using DICOM metadata: A quality assurance tool

Purpose: To develop an automated methodology to estimate patient examination dose in digital radiography (DR) imaging using DICOM metadata as a quality assurance (QA) tool. Methods: Patient examination and demographical information were gathered from metadata analysis of DICOM header data. The x-ray system radiation output (i.e., air KERMA) was characterized for all filter combinations used for patient examinations. Average patient thicknesses were measured for head, chest, abdomen, knees, and hands using volumetric images from CT. Backscatter factors (BSFs) were calculated from examination kVp. Patient entrance skin air KERMA (ESAK) was calculated by (1) looking up examination technique factors taken from DICOM header metadata (i.e., kVp and mA s) to derive an air KERMA (k{sub air}) value based on an x-ray characteristic radiation output curve; (2) scaling k{sub air} with a BSF value; and (3) correcting k{sub air} for patient thickness. Finally, patient entrance skin dose (ESD) was calculated by multiplying a mass–energy attenuation coefficient ratio by ESAK. Patient ESD calculations were computed for common DR examinations at our institution: dual view chest, anteroposterior (AP) abdomen, lateral (LAT) skull, dual view knee, and bone age (left hand only) examinations. Results: ESD was calculated for a total of 3794 patients; mean age was 11 ± 8 yr (range: 2 months to 55 yr). The mean ESD range was 0.19–0.42 mGy for dual view chest, 0.28–1.2 mGy for AP abdomen, 0.18–0.65 mGy for LAT view skull, 0.15–0.63 mGy for dual view knee, and 0.10–0.12 mGy for bone age (left hand) examinations. Conclusions: A methodology combining DICOM header metadata and basic x-ray tube characterization curves was demonstrated. In a regulatory era where patient dose reporting has become increasingly in demand, this methodology will allow a knowledgeable user the means to establish an automatable dose reporting program for DR and perform patient dose related QA testing for digital x-ray imaging.

60 APPLIED LIFE SCIENCES↗

SU-E-I-85: Absorbed Dose Estimation for a Commercially Available MicroCT Scanner

Purpose: To quantify the simulated absorbed dose delivered for a typical scan from a commercially available microCT scanner in order to aid in the dose estimation. Methods: The simulations were conducted using the Geant4 Monte Carlo Toolkit (version 10) with the standard electromagnetic classes. The Quantum FX microCT scanner (PerkinElmer, Waltham, MA) was modeled incorporating the energy fluence and angular distributions of generated photons, spatial dimensions of nominal source-to-object and source-to-detector distances. The energy distribution was measured using a spectrometer (X-123CdTe, Amptek Inc., Bedford, USA) with a 300 angular spread from the source for the 90 kVp X-ray beams with no additional filtration. The nominal distances from the source to object consisted of three setups: 154.0 mm, 104.0 mm, and 51.96 mm. Our simulations recorded the dose absorbed in a cylindrical phantom of PMMA with a fixed length of 2 cm and varying radii (10, 20, 30 and 40 mm) using 100 million incident photons. The averaged absorbed dose in the object was then quantified for all setups. An exposure measurement of 417 mR was taken using a Radcal 9095 system utilizing 10×9–180 ion chamber with the given technique of 90 kVp, 63 μA, and 12 s. The exposure rate was also simulated with same setup to calculate the conversion factor of the beam current and the number of incident photons. Results: For a typical cone-beam scan with non-filtered 90kVp, the dose coefficients (the absorbed dose per mAs) were 2.614, 2.549 and 2.467 μGy/mAs under source to object distance of 104 mm for the object diameters of 10 mm, 20 mm and 30 mm, respectively. Conclusion: A look-up table was developed where an investigator can estimate the delivered dose using this particular microCT given the scanning protocol (kVp and mAs) as well as the size of the scanned object.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fabrication Development for SPT-SLIM, a Superconducting Spectrometer for Line Intensity Mapping

Line Intensity Mapping (LIM) is a new observational technique that uses low-resolution observations of line emission to efficiently trace the large-scale structure of the Universe out to high redshift. Common mm/sub-mm emission lines are accessible from ground-based observatories, and the requirements on the detectors for LIM at mm-wavelengths are well matched to the capabilities of large-format arrays of superconducting sensors. We describe the development of an R = lambda/Delta lambda = 300 on-chip superconducting filter-bank spectrometer covering the 120-180 GHz band for future mm-LIM experiments, focusing on SPT-SLIM, a pathfinder LIM instrument for the South Pole Telescope. Radiation is coupled from the telescope optical system to the spectrometer chip via an array of feedhorn-coupled orthomode transducers. Superconducting microstrip transmission lines then carry the signal to an array of channelizing half-wavelength resonators, and the output of each spectral channel is sensed by a lumped element kinetic inductance detector (leKID). Key areas of development include incorporating new low-loss dielectrics to improve both the achievable spectral resolution and optical efficiency and development of a robust fabrication process to create a galvanic connection between ultra-pure superconducting thin-films to realize multi-material (hybrid) leKIDs. We provide an overview of the spectrometer design, fabrication process, and prototype devices.

microstrip resonators↗

Sci-Thur AM: YIS – 02: Imaging dose distributions through the detection of radiation-induced acoustic waves

Purpose: X-ray acoustic computed tomography (XACT) is an emerging technique that images the dose deposited within an object following linac irradiation by detecting acoustic waves induced via the photoacoustic effect. This work shows that XACT images can be formed in soft-tissue equivalent material and that dosimetric information can be extracted from such images. Methods: Acoustic waves induced in a water tank following irradiation by a 10 MV flattening filter free photon beam were detected with an immersion ultrasound transducer at 60 angles surrounding the radiation field. A back-projection algorithm was used to reconstruct an XACT image from the detected transducer signals. Profiles extracted from XACT images were compared to profiles measured with ion chambers as per the current clinical protocol. Results: XACT images were successfully formed of simple 4 cm × 4 cm and 6 cm × 3 cm fields, as well as of more complicated multi-leaf collimator defined fields. For the 6 cm × 3 cm field, 74% and 87% of the XACT profile points in the 6 cm and 3 cm dimensions, respectively, passed a 7% / 4 mm gamma test when compared to ion chamber measurements. In a complicated puzzle piece shaped field, 86% of the pixels in an extracted profile passed a 7% / 4 mm gamma test. Conclusions: XACT is capable of imaging the dose distribution delivered by a variety of field sizes and shapes in water, and is a viable technique for both water tank and in vivo dosimetry.

60 APPLIED LIFE SCIENCES↗