Search NASA⌕ Search

SEARCH · Search NASA

Results for “GAMMA”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,009 records · Page 56

Exclusive rare decay b{yields}s{gamma} of heavy b baryons

We present an analysis on the exclusive rare radiative decay modes {Sigma}{sub b}{yields}{Sigma}{gamma} and {Xi}{sub b}{yields}{Xi}{gamma}. The transition form factors which parametrize these processes are calculated using QCD light-cone sum rules. The decay widths we predict are {Gamma}({Sigma}{sub b}{yields}{Sigma}{gamma})=(7.21{+-}0.04)x10{sup -18} GeV and {Gamma}({Xi}{sub b}{yields}{Xi}{gamma})=(1.34{+-}0.07)x10{sup -16} GeV. The branching ratio of {Xi}{sub b}{yields}{Xi}{gamma} is predicted to be Br({Xi}{sub b}{yields}{Xi}{gamma})= (3.03{+-}0.10)x10{sup -4}.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurement of Branching Fractions, Isospin, and CP-Violating Asymmetries for Exclusive b{yields}d{gamma} Modes

We report new measurements of the decays B{sup +}{yields}{rho}{sup +}{gamma}, B{sup 0}{yields}{rho}{sup 0}{gamma}, and B{sup 0}{yields}{omega}{gamma} using a data sample of 657x10{sup 6} B meson pairs accumulated with the Belle detector at the KEKB e{sup +}e{sup -} collider. We measure branching fractions B(B{sup +}{yields}{rho}{sup +}{gamma})=(8.7{sub -2.7-1.1}{sup +2.9+0.9})x10{sup -7}, B(B{sup 0}{yields}{rho}{sup 0}{gamma})=(7.8{sub -1.6-1.0}{sup +1.7+0.9})x10{sup -7}, and B(B{sup 0}{yields}{omega}{gamma})=(4.0{sub -1.7}{sup +1.9}{+-}1.3)x10{sup -7}. We also report the isospin asymmetry {delta}({rho}{gamma})=-0.48{sub -0.19-0.09}{sup +0.21+0.08} and the first measurement of the direct CP-violating asymmetry A{sub CP}(B{sup +}{yields}{rho}{sup +}{gamma})=-0.11{+-}0.32{+-}0.09, where the first and second errors are statistical and systematic, respectively.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Tomotherapy treatment plan quality assurance: The impact of applied criteria on passing rate in gamma index method

Purpose: Pretreatment patient plan verification with gamma index (GI) metric analysis is standard procedure for intensity modulated radiation therapy (IMRT) treatment. The aim of this paper is to evaluate the variability of the local and global gamma index obtained during standard pretreatment quality assurance (QA) measurements for plans performed with Tomotherapy unit. The QA measurements were performed with a 3D diode array, using variable passing criteria: 3%/3 mm, 2%/2 mm, 1%/1 mm, each with both local and global normalization.Methods: The authors analyzed the pretreatment QA results for 73 verifications; 37 were prostate cancer plans, 16 were head and neck plans, and 20 were other clinical sites. All plans were treated using the Tomotherapy Hi-Art System. Pretreatment QA plans were performed with the commercially available 3D diode array ArcCHECK™. This device has 1386 diodes arranged in a helical geometry spaced 1 cm apart. The dose measurements were acquired on the ArcCHECK™ and then compared with the calculated dose using the standard gamma analysis method. The gamma passing rate (%GP), defined as the percentage of points satisfying the condition GI < 1, was calculated for different criteria (3%/3 mm, 2%/2 mm, 1%/1 mm) and for both global and local normalization. In the case of local normalization method, the authors set three dose difference threshold (DDT) values of 2, 3, and 5 cGy. Dose difference threshold is defined as the minimum absolute dose error considered in the analysis when using local normalization. Low-dose thresholds (TH) of 5% and 10% were also applied and analyzed.Results: Performing a paired-t-test, the authors determined that the gamma passing rate is independent of the threshold values for all of the adopted criteria (5%TH vs 10%TH, p > 0.1). Our findings showed that mean %GPs for local (or global) normalization for the entire study group were 93% (98%), 84% (92%), and 66% (61%) for 3%/3 mm, 2%/2 mm, and 1%/1 mm criteria, respectively. DDT was equal to 2 cGy for the local normalization analysis cases. The authors observed great variability in the resulting %GP. With 3%/3 mm gamma criteria, the overall passing rate with local normalization was 4.6% less on the average than with global one, as expected. The wide difference between %GP calculated with global or local approach is also confirmed by an unpaired t-test statistical analysis.Conclusions: The variability of %GP obtained confirmed the necessity to establish defined agreement criteria that could be universal and comparable between institutions. In particular, while the gamma passing rate does not depend on the choice of threshold, the choice of DDT strongly influences the gamma passing rate for local calculations. The difference between global and local %GP was statistically significant for prostate and other treatment sites when DDT was changed from 2 to 3 cGy.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-E-T-77: Comparison of 2D and 3D Gamma Analysis in Patient-Specific QA for Prostate VMAT Plans

Purpose: Patient-specific QA procedures for IMRT and VMAT are traditionally performed by comparing TPS calculations with measured single point values and plane dose distributions by means of gamma analysis. New QA devices permit us to calculate 3D dose distributions on patient anatomy as redundant secondary check and reconstruct it from measurements taken with 2D and 3D detector arrays. 3D dose calculations allow us to perform DVH-based comparisons with clinical relevance, as well as 3D gamma analysis. One of these systems (Compass, IBA Dosimetry) combines traditional 2D with new anatomical-based 3D gamma analysis. This work shows the ability of this system by comparing 2D and 3D gamma analysis in pre-treatment QA for several VMAT prostate plans. Methods: Compass is capable of calculating dose as secondary check from DICOM TPS data and reconstructing it from measurements taken by a 2D ion chamber array (MatriXX Evolution, IBA Dosimetry). Both 2D and 3D gamma tests are available to compare calculated and reconstructed dose in Compass with TPS RT Dose. Results: 15 VMAT prostate plans have been measured with Compass. Dose is reconstructed with Compass for these plans. 2D gamma comparisons can be done for any plane from dose matrix. Mean gamma passing rates for isocenter planes (axial, coronal, sagittal) are (99.7±0.2)%, (99.9±0.1)%, (99.9±0.1)% for reconstructed dose planes. 3D mean gamma passing rates are (98.5±1.7)% for PTVs, (99.1±1.5)% for rectum, (100.0±0.0)% for bladder, (99.6±0.7)% for femoral heads and (98.1±4.1)% for penile bulb. Conclusion: Compass is a powerful tool to perform a complete pre-treatment QA analysis, from 2D techniques to 3D DVH-based techniques with clinical relevance. All reported values for VMAT prostate plans are in good agreement with TPS values. This system permits us to ensure the accuracy in the delivery of VMAT treatments completing a full patient-specific QA program.

60 APPLIED LIFE SCIENCES↗

SU-E-T-647: Quality Assurance of VMAT by Gamma Analysis Dependence On Low-Dose Threshold

Purpose: The AAPM TG-119 instructed institutions to use low-dose threshold (LDT) of 10% or a ROI determined by the jaw when they collected gamma analysis QA data of planar dose distribution. Also, based on a survey by Nelms and Simon, more than 70% of institutions use a LDT between 0% and 10% for gamma analysis. However, there are no clinical data to quantitatively demonstrate the impact of the LDT on the gamma index. Therefore, we performed a gamma analysis with LDTs of 0% to 15% according to both global and local normalization and different acceptance criteria: 3%/3 mm, 2%/2 mm, and 1%/1 mm. Methods: A total of 30 treatment plans—10 head and neck, 10 brain, and 10 prostate cancer cases—were randomly selected from the Varian Eclipse TPS, retrospectively. For the gamma analysis, a predicted portal image was acquired through a portal dose calculation algorithm in the Eclipse TPS, and a measured portal image was obtained using a Varian Clinac iX and an EPID. Then, the gamma analysis was performed using the Portal Dosimetry software. Results: For the global normalization, the gamma passing rate (%GP) decreased as the LDT increased, and all cases of low-dose thresholds exhibited a %GP above 95% for both the 3%/3 mm and 2%/2 mm criteria. However, for local normalization, the %GP increased as LDT increased. The gamma passing rate with LDT of 10% increased by 6.86%, 9.22% and 6.14% compared with the 0% in the case of the head and neck, brain and prostate for 3%/3 mm criteria, respectively. Conclusion: Applying the LDT in the global normalization does not have critical impact to judge patient-specific QA results. However, LDT for the local normalization should be carefully selected because applying the LDT could affect the average of the %GP to increase rapidly.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-G-BRB-16: Vulnerabilities in the Gamma Metric

Purpose: To explore vulnerabilities in the gamma index metric that undermine its wide use as a radiation therapy quality assurance tool. Methods: 2D test field pairs (images) are created specifically to achieve high gamma passing rates, but to also include gross errors by exploiting the distance-to-agreement and percent-passing components of the metric. The first set has no requirement of clinical practicality, but is intended to expose vulnerabilities. The second set exposes clinically realistic vulnerabilities. To circumvent limitations inherent to user-specific tuning of prediction algorithms to match measurements, digital test cases are manually constructed, thereby mimicking high-quality image prediction. Results: With a 3 mm distance-to-agreement metric, changing field size by ±6 mm results in a gamma passing rate over 99%. For a uniform field, a lattice of passing points spaced 5 mm apart results in a passing rate of 100%. Exploiting the percent-passing component, a 10×10 cm{sup 2} field can have a 95% passing rate when an 8 cm{sup 2}=2.8×2.8 cm{sup 2} highly out-of-tolerance (e.g. zero dose) square is missing from the comparison image. For clinically realistic vulnerabilities, an arc plan for which a 2D image is created can have a >95% passing rate solely due to agreement in the lateral spillage, with the failing 5% in the critical target region. A field with an integrated boost (e.g whole brain plus small metastases) could neglect the metastases entirely, yet still pass with a 95% threshold. All the failure modes described would be visually apparent on a gamma-map image. Conclusion: The %gamma<1 metric has significant vulnerabilities. High passing rates can obscure critical faults in hypothetical and delivered radiation doses. Great caution should be used with gamma as a QA metric; users should inspect the gamma-map. Visual analysis of gamma-maps may be impractical for cine acquisition.

60 APPLIED LIFE SCIENCES↗

Derivation of a Multiparameter Gamma Model for Analyzing the Residence-Time Distribution Function for Nonideal Flow Systems as an Alternative to the Advection-Dispersion Equation

A new residence-time distribution (RTD) function has been developed and applied to quantitative dye studies as an alternative to the traditional advection-dispersion equation (AdDE). The new method is based on a jointly combined four-parameter gamma probability density function (PDF). The gamma residence-time distribution (RTD) function and its first and second moments are derived from the individual two-parameter gamma distributions of randomly distributed variables, tracer travel distance, and linear velocity, which are based on their relationship with time. The gamma RTD function was used on a steady-state, nonideal system modeled as a plug-flow reactor (PFR) in the laboratory to validate the effectiveness of the model. The normalized forms of the gamma RTD and the advection-dispersion equation RTD were compared with the normalized tracer RTD. The normalized gamma RTD had a lower mean-absolute deviation (MAD) (0.16) than the normalized form of the advection-dispersion equation (0.26) when compared to the normalized tracer RTD. The gamma RTD function is tied back to the actual physical site due to its randomly distributed variables. The results validate using the gamma RTD as a suitable alternative to the advection-dispersion equation for quantitative tracer studies of non-ideal flow systems.

Embry, Irucka↗

Delayed Fission Gamma-ray Characteristics of 232 Th, 233 U, 235 U, 238 U, and 239 Pu

Delayed fission gamma-rays play an important role in determining the time dependent ionizing dose for experiments in the central irradiation cavity of the Annular Core Research Reactor (ACRR). Delayed gamma-rays are produced from both fission product decay and from activation of materials in the core, such as cladding and support structures. Knowing both the delayed gamma-ray emission rate and the time-dependent gamma-ray energy spectrum is necessary in order to properly determine the dose contributions from delayed fission gamma-rays. This information is especially important when attempting to deconvolute the time-dependent neutron, prompt gamma-ray, and delayed gamma-ray contribution to the response of a diamond photo-conducting diode (PCD) or fission chamber in time frames of milliseconds to seconds following a reactor pulse. This work focused on investigating delayed gamma-ray characteristics produced from fission products from thermal, fast, and high energy fission of Th-232, U-233, U-235, U-238, and Pu-239. This work uses a modified version of CINDER2008, a transmutation code developed at Los Alamos National Laboratory, to model time and energy dependent photon characteristics due to fission. This modified code adds the capability to track photon-induced transmutations, photo-fission, and the subsequent radiation caused by fission products due to photo-fission. The data is compared against previous work done with SNL- modified CINDER2008 and experimental data and other published literature, including ENDF/B-VII.1. The ability to produce a high-fidelity (7,428 group) energy-dependent photon fluence at various times post-fission can improve the delayed photon characterization for radiation effects tests at research reactors, as well as other applications.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

User Manual for MC2-3 Gamma Library Generation

This document presents a detailed description of generating the gamma library for MC 2 -3 which includes delayed gammas and betas based on the 94 gamma energy groups. The updated methodologies associated with heating and gamma calculations are introduced, which account for the self-shielding effect on KERMA factors and perform the gamma transport calculations to condense the gamma data from 94 to 21 groups. For these updates, the PreGAMMA code was developed to prepare NJOY inputs and generate delayed gammas and betas, and the GenGAMMA code was updated to process the outputs of PreGAMMA and NJOY. This document briefly discusses verification results of the new gamma library using the ABTR fuel pin and the EBR-II benchmark problem.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Steady-State Thermal-Hydraulic Analysis and Bowing Reactivity Evaluation Methods Based on Neutron and Gamma Transport Calculations

With the advancement of computer technology, the variational nodal transport code VARIANT is now routinely used for sodium-cooled fast reactor (SFR) design analysis. In particular, VARIANT transport calculations are usually performed for whole core neutronics analyses and for fuel cycle analyses with REBUS-3. However, the steady-state thermal hydraulics analysis with the SE2-ANL coed and the assembly bowing reactivity calculation with the structural analysis with the NUBOW-3D code are still performed with the DIF3D finite difference diffusion theory code. Furthermore, the DIF3D diffusion calculation for these applications is performed with only six triangular meshes per hexagonal assembly, and the SE2-ANL code determines the pin power distributions approximately by assuming that the power distribution within an assembly is separable in the radial and axial directions. In order to overcome the limitations and to improve the accuracy of the existing methods, it was proposed to develop the relevant computational methods based on the transport calculations with the VARIANT and PROTEUS-SN codes. The objectives of this study are to develop a new heating calculation method based on the coupled neutron and gamma transport calculations with VARIANT, to implement the new heating calculation method into the SE2-ANL steady-state thermal-hydraulics analysis code with improved numerical algorithms and additional capabilities for automatic flow allocation calculations, and to develop a method to calculate bowing reactivity coefficients based on the VARIANT core solutions and the PROTEUS-SN assembly solutions, which can be used in NUBOW-3D calculations. A new, coupled neutron and gamma heating calculation procedure has been developed based on VARIANT transport calculations. In the new heating calculation procedure, the neutron flux distribution is first determined by solving an eigenvalue transport problem using the VARIANT transport code. Using the calculated neutron flux, the intra-nodal gamma source distributions are calculated to be consistent with the neutron flux distribution with the GAMSOR code. For this, the GAMSOR code has been updated to generate the intra-nodal gamma source distributions in the form of the VARSRC dataset of VARIANT. With this gamma source distribution, the gamma flux distribution is determined by solving a fixed source gamma transport problem using VARIANT again. With the neutron and gamma flux distributions, the heat generation rates are evaluated at individual fuel pins and assembly duct walls, without assuming separable axial and radial profiles for the intra-assembly power distribution.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Gamma Dose Measurements in ZPPR-15

Gamma doses were measured in the Zero Power Plutonium Reactor (ZPPR) to provide data for validation of calculations of gamma heating in important reactor components. Stainless steel-encapsulated LiF thermoluminescent dosimeters (TLDs) were irradiated in two configurations in ZPPR-15B and one configuration in ZPPR-15D to provide gamma heating data for the Integral Fast Reactor design in the mid-1980s. The ZPPR-15 experimental records were used to develop detailed as-built Monte Carlo models for the gamma dose measurements in ZPPR-15B and ZPPR-15D. These Monte Carlo models can be converted to deterministic models for calculations with deterministic codes. The reported uncertainty in the published gamma dose measurements is just the statistical uncertainty in the TLD readout. In addition to this statistical uncertainty in the TLD readout, several corrections and other factors contribute to the total uncertainty for the gamma dose measurements. The total uncertainty for the gamma dose measurements can be significantly larger than the published statistical uncertainty for the TLD readout. All known contributions to the total uncertainty were analyzed, and a total uncertainty was derived for the ZPPR-15 gamma dose measurements.

36 MATERIALS SCIENCE↗

Characterizing the Gamma-Ray Emission Properties of the Globular Cluster M5 with the Fermi-LAT

Abstract We analyzed the globular cluster M5 (NGC 5904) using 15 yr of gamma-ray data from the Fermi Large Area Telescope (LAT). Using rotation ephemerides generated from Arecibo and FAST radio telescope observations, we searched for gamma-ray pulsations from the seven millisecond pulsars (MSPs) identified in M5. We detected no significant pulsations from any of the individual pulsars. In addition, we searched for possible variations of the gamma-ray emission as a function of orbital phase for all six MSPs in binary systems, but we did not detect any significant modulations. The gamma-ray emission from the direction of M5 is well described by an exponentially cutoff power-law spectral model, although other models cannot be excluded. The phase-averaged emission is consistent with being steady on a timescale of a few months. We estimate the number of MSPs in M5 to be between 1 and 10, using the gamma-ray conversion efficiencies for well-characterized gamma-ray MSPs in the Third Fermi-LAT Catalog of Gamma-ray Pulsars, suggesting that the sample of known MSPs in M5 is (nearly) complete, even if it is not currently possible to rule out a diffuse component of the observed gamma rays from the cluster.

Astronomy & Astrophysics↗

Calculation of the effectiveness of a gamma telescope

A calculation is given of the effectiveness of recording of gamma quanta by a gamma telescope. Consideration of the isotropic nature of the stream of gamma quanta reaching the gamma telescope revealed that low energy gamma quanta are recorded relatively more effectively, since they are recorded from a wider solid angle than higher energy gamma quanta. The problem is solved of determining the effectiveness of recording of gamma quanta and determination of their energies by a gamma telescope.

Rylov, Y. A.↗

High-energy gamma-ray astronomy

The subject of gamma-ray astronomy is discussed with emphasis on celestial gamma rays with energies in excess of 10 MeV. Early observations of such gamma rays are reviewed, a gamma-ray spark-chamber telescope is described together with a gas Cerenkov-counter telescope, and the gamma-ray sky is delineated. It is shown that the diffuse high-energy gamma radiation from the galactic plane probably results primarily from cosmic-ray interactions with interstellar matter. Mechanisms for gamma-ray production are identified, and it is noted that the general galactic radiation may prove to be of great value in studies of galactic structure. Possible sources are considered for the diffuse celestial radiation, and discrete sources are described, including the Crab pulsar, the Vela remnant, the Cygnus region, and Gould's Belt. Future developments in gamma-ray astronomy are considered.

Fichtel, C.↗

SAS-2 galactic gamma-ray results. 2: Localized sources

Gamma ray emission was detected from the radio pulsars PSR 1818-04 and PSR 1747-46, in addition to the previously reported gamma ray emission from the Crab and Vela pulsars. Because the Crab pulsar is the only one observed in the optical and X-ray bands, these gamma ray observations suggest a uniquely gamma ray phenomenon occurring in a fraction of the radio pulsars. PSR 1818-04 has a gamma ray luminosity comparable to that of the Crab pulsar, whereas the luminosities of PSR 1747-46 and the Vela pulsar are approximately an order of magnitude lower. SAS-2 data for pulsar correlations yielded upper limits to gamma ray luminosity for 71 other radio pulsars. For five of the closest pulsars, upper limits for gamma ray luminosity are found to be at least three orders of magnitude lower than that of the Crab pulsar. Gamma ray enhancement near the Milky Way satellite galaxy and the galactic plane in the Cygnus region is also discussed.

Hartman, R. C.↗

SAS-2 gamma-ray observations of PSR 1747-46

Evidence is reported for the observation of gamma-ray emission from the radio pulsar PSR 1747-46 by the gamma-ray telescope aboard SAS 2. The evidence is based on the presence of both an approximately 3-sigma enhancement of gamma rays at the pulsar's location and an approximately 4-sigma peak in the phase plot of 79 gamma-ray events whose phase was calculated from the pulsar's known period. The gamma-ray pulsation is found to appear at a phase lag of about 0.16 from that predicted by the radio observations. The pulsed gamma-ray fluxes above 35 MeV and 100 MeV are estimated, and it is shown that the gamma-ray pulse width is similar to the radio pulse width. It is concluded that PSR 1747-46 is a most likely candidate for pulsed gamma-ray emission.

Thompson, D. J.↗

Atmospheric gamma ray angle and energy distributions from sea level to 3.5 g/sq cm and 2 to 25 MeV

Differential fluxes of gamma rays were calculated for energies of 2-25 MeV, zenith angles of 0-50 deg and 180-130 deg, and atmospheric depths from nominal sea level, 1000 g/sq cm, to float altitude, 3.5 g/sq cm residual atmosphere. Above 100 g/sq cm growth curves were constructed to estimate the contribution of the extraterrestrial gamma ray flux to the total downward-moving flux, while the upward-moving gamma rays were taken to be strictly of atmospheric origin. Below 100 g/sq cm, all gamma rays originate in the atmosphere. The downward atmospheric flux increases by almost two orders of magnitude between float altitude and the Pfotzer maximum, while the extraterrestrial flux is attenuated exponentially. Gamma rays produced by neutron interactions with the carbon in the scintillator liquid are eliminated by constructing growth curves for downward-moving gamma rays at high altitudes and are negligible compared with downward-moving gamma rays at lower altitudes and upward-moving gamma rays at all altitudes.

Ryan, J. M.↗

Future prospects for gamma-ray astronomy

As gamma-ray astronomy moves from the discovery to the exploratory phase, the promise of gamma-ray astrophysics noted by theorists in the late 1940s and 1950s is beginning to be realized. In the future, satellites should carry instruments that will have over an order of magnitude greater sensitivity than those flown thus far, and, for at least some portions of the gamma-ray energy range, these detectors will also have substantially improved energy and angular resolution. The information to be obtained from these experiments should greatly enhance our knowledge of several astrophysical phenomena including the very energetic and nuclear processes associated with compact objects, astrophysical nucleosynthesis, solar particle acceleration, the chemical composition of the planets and other bodies of the solar system, the structure of our galaxy, the origin and dynamic pressure effects of the cosmic rays, high energy particles and energetic processes in other galaxies especially active ones, and the degree of matter-antimatter symmetry of the universe. The gamma-ray results of the forthcoming programs such as Gamma-I, the Gamma Ray Observatory, the gamma-ray burst network, Solar Polar, and very high energy gamma-ray telescopes on the ground will almost certainly provide justification for more sophisticated telescopes. These advanced instruments might be placed on the Space Platform currently under study by N.A.S.A.

Fichtel, C.↗