Search NASA⌕ Search

SEARCH · Search NASA

Results for “ION SOURCE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,009 records · Page 56

Self-induced steady-state magnetic field in the negative ion sources with localized rf power deposition

The study is in the scope of a recent activity on modeling of SPIDER (Source for Production of Ions of Deuterium Extracted from RF plasma) which is under development regarding the neutral beam injection heating system of ITER. The regime of non-ambipolarity in the source, established before, is completed here by introducing in the model the steady state magnetic field, self-induced in the discharge due to the dc current flowing in it. Strong changes in the discharge structure are reported.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Effects of adsorption and roughness upon the collision processes at the convertor surface of a plasma sputter negative ion source

Atomic collision processes associated with surface production of negative hydrogen ions (H{sup -}) by particle reflection at molybdenum surface immersed in hydrogen plasma have been investigated. To calculate sputtering yields of Cs, as well as energy spectra and angular distributions of reflected hydrogen atoms from molybdenum surface by H{sup +} ion and Cs{sup +} ion bombardments, a Monte Carlo simulation code ACAT (Atomic Collision in Amorphous Target) was run with the corresponding surface conditions. A fractal surface model has been developed and adopted to ACAT for evaluating the effect due to roughness of target material. The results obtained with ACAT have indicated that the retention of hydrogen atoms leads to the reduction in sputtering yields of Cs, and the surface roughness does largely affect the sputtering yields of Cs.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Experimental optimization of beam quality extracted from a duoplasmatron proton ion source

The LANSCE accelerator facility operates with two independent ion injectors for H⁺ and H⁻ particle beams. The H⁺ ion beam is formed using a duoplasmatron source followed by a 750 keV Cockroft-Walton accelerating column. Formation of an optimal plasma meniscus is an important feature for minimizing beam emittance, and maximizing beam brightness. A series of experiments were performed to find the optimal combination of extraction voltage and extracted current for the H⁺ beam. Measurements yielded the best ratio of beam perveance to Child–Langmuir perveance of 0.52 for maximizing beam brightness.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Importance of electric field for H{sup -} extraction in a volume-type hydrogen negative ion source

The effect upon extraction of negative hydrogen ions (H{sup -}) due to electric field near the extractor hole of a H{sup -} source is studied experimentally and theoretically. Probe measurements show that the extraction electric field penetrates into the plasma in the region near the extractor hole. Based on this observation a three-dimensional H{sup -} trajectory calculation that takes into account the local electric field distribution near the plasma electrode has been carried out. The validity of the trajectory calculation was examined by comparing the results with experimentally measured changes in H{sup -} current detected by a Faraday cup due to irradiation of a pulse laser beam in the region close to the extractor hole. The calculation results qualitatively explain the changes in H{sup -} current observed in the experiment. The calculation results also predict that the amount of H{sup -} current passing through the extractor hole changes with the electric field: the penetration of the electric field substantially enhances the H{sup -} extraction current, because it produces an electric field to attract H{sup -} toward the extraction hole.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A collisional radiative model of hydrogen plasmas developed for diagnostic purposes of negative ion sources

A collisional radiative model of low-pressure hydrogen plasmas is elaborated and applied in optical emission spectroscopy diagnostics of a single element of a matrix source of negative hydrogen ions. The model accounts for the main processes determining both the population densities of the first ten states of the hydrogen atom and the densities of the positive hydrogen ions H{sup +}, H{sub 2}{sup +}, and H{sub 3}{sup +}. In the calculations, the electron density and electron temperature are varied whereas the atomic and molecular temperatures are included as experimentally obtained external parameters. The ratio of the H{sub α} to H{sub β} line intensities is calculated from the numerical results for the excited state population densities, obtained as a solution of the set of the steady-state rate balance equations. The comparison of measured and theoretically obtained ratios of line intensities yields the values of the electron density and temperature as well as of the degree of dissociation, i.e., of the parameters which have a crucial role for the volume production of the negative ions.

74 ATOMIC AND MOLECULAR PHYSICS↗

Development of ion source for simulation of edge localized mode in divertor plasma

A helium ion beam is injected into a linear plasma device for the development of an ion beam source simulating high energy particle flux in divertor plasma. Beam current density more than 10 mA/cm{sup 2} is extracted. Measurement of beam currents indicates that the beam is transported along the linear device and reaches to the downstream end plate.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Pulse modulated microwave operation on large bore electron cyclotron resonance ion source with cylindrically comb-shaped magnetic fields configuration

In order to enhance efficiency of an electron cyclotron resonance (ECR) plasma for broad and dense ion beam source under the low pressure, the magnetic field configuration is constructed by a pair of comb-shaped magnet which has opposite polarity each other, and which cylindrically surrounds the plasma chamber. By using the pulse microwave mode operation, we aim at generation of plasma with parameters that cannot be achieved at the continuous microwave (cw) mode. The maximum beam current is obtained in the experimental condition of the pulse width 100-200 {mu}s at the duty ratio 40%-50%. According to probe measurements of the ECR plasma, it is found the electron density in the pulse mode is larger than that in the cw mode, while the electron temperatures in the pulse mode were lower than that in the cw mode. These indirect evidences cause to enhance ion beams in the pulse mode operation, and then suggest a spread of operation windows for plasma parameters suitable to production of molecular or cluster ions.

43 PARTICLE ACCELERATORS↗

Very Large Area/Volume Microwave ECR Plasma and Ion Source

The present invention is an apparatus and method for producing very large area and large volume plasmas. The invention utilizes electron cyclotron resonances in conjunction with permanent magnets to produce dense, uniform plasmas for long life ion thruster applications or for plasma processing applications such as etching, deposition, ion milling and ion implantation. The large area source is at least five times larger than the 12-inch wafers being processed to date. Its rectangular shape makes it easier to accommodate to materials processing than sources that are circular in shape. The source itself represents the largest ECR ion source built to date. It is electrodeless and does not utilize electromagnets to generate the ECR magnetic circuit, nor does it make use of windows.

Foster, John E.↗

A simple radionuclide-driven single-ion source

We describe a source capable of producing single barium ions through nuclear recoils in radioactive decay. The source is fabricated by electroplating {sup 148}Gd onto a silicon {alpha}-particle detector and vapor depositing a layer of BaF{sub 2} over it. {sup 144}Sm recoils from the alpha decay of {sup 148}Gd are used to dislodge Ba{sup +} ions from the BaF{sub 2} layer and emit them in the surrounding environment. The simultaneous detection of an {alpha} particle in the substrate detector allows for tagging of the nuclear decay and of the Ba{sup +} emission. The source is simple, durable, and can be manipulated and used in different environments. We discuss the fabrication process, which can be easily adapted to emit most other chemical species, and the performance of the source.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Roles of a plasma grid in a negative hydrogen ion source

The plasma grid is electrically biased with respect to other parts of source chamber wall in both volume sources and sources seeded with alkali metals. The roles of the plasma grid in these two kinds of sources will be described. The main functions of the plasma grid in volume sources are: optimizing the extracted negative ion current, reducing the co-extracted electron current, controlling the axial plasma potential profile, recycling the hydrogen atoms to molecules, concentrating the negative ions near its surface and, when biased positive, depleting the electron population near its surface. These functions are maintained in the sources seeded with alkali metals. However an additional function appears in the Cs seeded sources, namely direct emission of negative ions under positive ion and neutral hydrogen bombardment.

07 ISOTOPE AND RADIATION SOURCES↗

In-Situ Ion Source Cleaning: Review of Chemical Mechanisms and Evaluation Data at Production Fabs

Since the concept of chemical in-situ ion implanter cleaning was introduced at IIT2006 [1], evaluations of the XeF{sub 2} cleaning technology have taken place or are ongoing at more than 40 production fabs worldwide. Testing has been focused on assessing effects of cleaning in the source arc chamber and extraction regions. In this paper we describe use of the cleaning technology in a production environment and summarize evaluation data showing advantages of the technology for improving ion source life, reducing glitching, improving beam auto-tuning and avoiding species cross-contamination. More details of the evaluations are given in several separate papers submitted to this Conference. We have supplemented the fab production data with laboratory experiments designed to investigate the reactivity of XeF{sub 2} and fundamental aspects of the source deposition and cleaning processes. These experiments are summarized here, and more details can be found in separate papers submitted to this Conference.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Influence of ion source configuration and its operation parameters on the target sputtering and implantation process

In the work, investigation of the features and operation regimes of sputter enhanced ion-plasma source are presented. The source is based on the target sputtering with the dense plasma formed in the crossed electric and magnetic fields. It allows operation with noble or reactive gases at low pressure discharge regimes, and, the resulting ion beam is the mixture of ions from the working gas and sputtering target. Any conductive material, such as metals, alloys, or compounds, can be used as the sputtering target. Effectiveness of target sputtering process with the plasma was investigated dependently on the gun geometry, plasma parameters, and the target bias voltage. With the applied accelerating voltage from 0 to 20 kV, the source can be operated in regimes of thin film deposition, ion-beam mixing, and ion implantation. Multi-component ion beam implantation was applied to {alpha}-Fe, which leads to the surface hardness increasing from 2 GPa in the initial condition up to 3.5 GPa in case of combined N{sub 2}-C implantation. Projected range of the implanted elements is up to 20 nm with the implantation energy 20 keV that was obtained with XPS depth profiling.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Spatial distribution of the charged particles and potentials during beam extraction in a negative-ion source

We report on the characteristics of the electronegative plasma in a large-scale hydrogen negative ion (H{sup -}) source. The measurement has been made with a time-resolved Langmuir probe installed in the beam extraction region. The H{sup -} density is monitored with a cavity ring-down system to identify the electrons in the negative charges. The electron-saturation current decreases rapidly after starting to seed Cs, and ion-ion plasma is observed in the extraction region. The H{sup -} density steps down during the beam extraction and the electron density jumps up correspondingly. The time integral of the decreasing H{sup -} charge density agrees well with the electron charge collected with the probe. The agreement of the charges is interpreted to indicate that the H{sup -} density decreasing at the beam extraction is compensated by the electrons diffusing from the driver region. In the plasmas with very low electron density, the pre-sheath of the extraction field penetrates deeply inside the plasmas. That is because the shielding length in those plasmas is longer than that in the usual electron-ion plasmas, and furthermore the electrons are suppressed to diffuse to the extraction region due to the strong magnetic field.

43 PARTICLE ACCELERATORS↗

Survey of ion plating sources

Ion plating is a plasma deposition technique where ions of the gas and the evaporant have a decisive role in the formation of a coating in terms of adherence, coherence, and morphological growth. The range of materials that can be ion plated is predominantly determined by the selection of the evaporation source. Based on the type of evaporation source, gaseous media and mode of transport, the following will be discussed: resistance, electron beam sputtering, reactive and ion beam evaporation. Ionization efficiencies and ion energies in the glow discharge determine the percentage of atoms which are ionized under typical ion plating conditions. The plating flux consists of a small number of energetic ions and a large number of energetic neutrals. The energy distribution ranges from thermal energies up to a maximum energy of the discharge. The various reaction mechanisms which contribute to the exceptionally strong adherence - formation of a graded substrate/coating interface are not fully understood, however the controlling factors are evaluated. The influence of process variables on the nucleation and growth characteristics are illustrated in terms of morphological changes which affect the mechanical and tribological properties of the coating.

Spalvins, T.↗

Production of U beam from RIKEN 18 GHz electron cyclotron resonance ion source

For the RIKEN radio isotope factory (RIBF) project, we produced the multicharged uranium beam with two methods. To produce lower charge state U ion beams (14+-20+) we used the UF{sub 6} gas as an ionized gas. The typical beam intensity of U{sup 14+-20+} was 2-1 particle {mu}A at the extraction voltage of 14 kV. To produce higher charge state U ion beam (U{sup 35+}), we chose the sputtering method. The beam intensity was 70 particle nA at the extraction voltage of 5.4 kV. Using this method, we successfully produced multicharged U beam continuously for one month without break for RIBF commissioning.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

An inductively heated hot cavity catcher laser ion source

An inductively heated hot cavity catcher has been constructed for the production of low-energy ion beams of exotic, neutron-deficient Ag isotopes. A proof-of-principle experiment has been realized by implanting primary {sup 107}Ag{sup 21+} ions from a heavy-ion cyclotron into a graphite catcher. A variable-thickness nickel foil was used to degrade the energy of the primary beam in order to mimic the implantation depth expected from the heavy-ion fusion-evaporation recoils of N = Z {sup 94}Ag. Following implantation, the silver atoms diffused out of the graphite and effused into the catcher cavity and transfer tube, where they were resonantly laser ionized using a three-step excitation and ionization scheme. Following mass separation, the ions were identified by scanning the frequency of the first resonant excitation step while recording the ion count rate. Ion release time profiles were measured for different implantation depths and cavity temperatures with the mean delay time varying from 10 to 600 ms. In addition, the diffusion coefficients for silver in graphite were measured for temperatures of 1470 K, 1630 K, and 1720 K, from which an activation energy of 3.2 ± 0.3 eV could be determined.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of Li+ alumino-silicate ion source

To uniformly heat targets to electron-volt temperatures for the study of warm dense matter, one strategy is to deposit most of the ion energy at the peak of energy loss (dE/dx) with a low (E< 5 MeV) kinetic energy beam and a thin target[1]. Lower mass ions have a peak dE/dx at a lower kinetic energy. To this end, a small lithium (Li+) alumino-silicate source has been fabricated, and its emission limit has been measured. These surface ionization sources are heated to 1000-1150 C where they preferentially emit singly ionized alkali ions. Alumino-silicates sources of K+ and Cs+ have been used extensively in beam experiments, but there are additional challenges for the preparation of high-quality Li+ sources: There are tighter tolerances in preparing and sintering the alumino-silicate to the substrate to produce an emitter that gives uniform ion emission, sufficient current density and low beam emittance. We report on recent measurements ofhigh ( up to 35 mA/cm2) current density from a Li+ source. Ion species identification of possible contaminants is being verified with a Wien (E x B) filter, and via time-of-flight.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗