Search NASA⌕ Search

SEARCH · Search NASA

Results for “Imaging techniques”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,009 records · Page 56

High-resolution ptychographic imaging enabled by high-speed multi-pass scanning

As a coherent diffraction imaging technique, ptychography provides high-spatial resolution beyond Rayleigh’s criterion of the focusing optics, but it is also sensitively affected by the decoherence coming from the spatial and temporal variations in the experiment. Here we show that high-speed ptychographic data acquisition with short exposure can effectively reduce the impact from experimental variations. To reach a cumulative dose required for a given resolution, we further demonstrate that a continuous multi-pass scan via high-speed ptychography can achieve high-resolution imaging. This low-dose scan strategy is shown to be more dose-efficient, and has potential for radiation-sensitive sample studies and time-resolved imaging.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Summary of the first neutron image data collected at the National Ignition Facility

A summary of data and results from the first neutron images produced by the National Ignition Facility (NIF), Lawrence Livermore National Laboratory, Livermore, CA, USA are presented. An overview of the neutron imaging technique is presented, as well as a synopsis of the data collected and measurements made to date. Data form directly driven, DT filled microballoons, as well as, indirectly driven, cryogenically layered ignition experiments are presented. The data presented show that the primary cores from directly driven implosions are approximately twice as large, 64 {+-} 3 {mu}m, as indirect cores 25 {+-} 4 and 29 {+-} 4 {mu}m and more asymmetric, P2/P0 = 47% vs. -14% and 7%. Further, comparison with the size and shape of X-ray image data on the same implosions show good agreement, indicating X-ray emission is dominated by the hot regions of the implosion.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Three-dimensional controlled-source electromagnetic and magnetotelluric joint inversion

The growing use of the controlled-source electromagnetic method (CSEM) and magnetotellurics (MT) for exploration applications has been driving the development of data acquisition technologies, and three-dimensional (3-D) modeling and imaging techniques. However, targeting increasingly complex geological environments also further enhances the problems inherent in large-scale inversion, such as non-uniqueness and resolution issues. In this paper, we report on two techniques to mitigate these problems. We use 3-D joint CSEM and MT inversion to improve the model resolution. To avoid the suppression of the resolution capacities of one data type, and thus to balance the use of inherent, and ideally complementary information content, different data reweighting schemes are proposed. Further, a hybrid model parameterization approach is presented, where traditional cell-based model parameters are used simultaneously within a parametric inversion. The idea is to limit the non-uniqueness problem, typical for 3-D imaging problems, in order to allow for a more focusing inversion. The methods are demonstrated using synthetic data generated from models with a strong practical relevance.

54 ENVIRONMENTAL SCIENCES↗

Atomic imaging of the coherent interface between orientedly-attached Mn{sub 3}O{sub 4} nanoparticles

In this paper, coherent interfaces between orientedly-attached (OA) Mn{sub 3}O{sub 4} nanoparticles are fully reconstructed based on atomic-scale high angle annular dark field (HAADF) - scanning transmission electron microscopy (STEM) direct imaging technique. According to the characterization, five characteristics of the oriented attachment between Mn{sub 3}O{sub 4} are proposed: (1) [100]{sub Mn3O4} direction sharing; (2) crystallographic plane sharing for every two attached particles; (3) preference for O{sup 2−} close-packed crystallographic planes to form the OA interface; (4) “defect transfers” compensating the deviation between the macroscopic interface and the atomic interface; (5) possible chemical state changes of the interfacial atoms. - Highlights: • Advanced Cs-corrected STEM is applied to obtain atomic-scale images. • The complex interfaces between orientedly-attached Mn{sub 3}O{sub 4} nanoparticles are fully reconstructed. • “Defect transfer” phenomenon is observed for the first time.

36 MATERIALS SCIENCE↗

LITE-SM: A Light Sheet Illuminator Compatible with Super Resolution and Single Molecule Imaging

The LITE-SM (hereinafter referred to as the Tilt-SM) is a light sheet illumination system purpose-built for single molecule (SM) imaging. SM imaging is a fluorescence imaging technique where individual molecules can be tracked in living cells/tissues in real time allowing for unprecedented insights into the intracellular dynamics of these molecules. The innovative all-mirror optical design greatly reduces/eliminates the aberrations that plague lens-based designs. This iteration of the Tilt-SM has significantly better optical performance then its predecessor with over 10x increase in optical power at the sample, allowing for the use of much smaller and more cost-effective lasers then the original Phase 1 system. Excellent STORM imaging as well as SM tracking has been achieved, satisfying the key objectives of this study.

59 BASIC BIOLOGICAL SCIENCES↗

Updates on MURAVES Project at Mt. Vesuvius

The MUon RAdiography of VESuvius (MURAVES) project aims to employ muography imaging techniques to investigate the internal structure of the summit of Mount Vesuvius, an active volcano located near Naples, Italy. This paper reports recent advancements in data analysis and simulation tools that significantly improve the quality and reliability of the experiment’s results. A new track selection method, referred to as the Golden Selection, has been developed to identify high-quality muon tracks by applying an improved χ 2 -based criterion. This method enhances the signal-to-background ratio and improves the resolution of the resulting muographic images. Moreover, the simulation framework has been upgraded through the integration of the MULDER (MUon simuLation for DEnsity Reconstruction) library, which consolidates the functionalities of previously used libraries into a single, unified platform. MULDER enables efficient and accurate modeling of muon flux variations induced by topographical features. A good agreement is observed between the simulated and measured muon flux maps, validating the effectiveness of the new analysis and simulation approaches.

Cosmic rays↗

Adaptive optical third-harmonic generation microscopy for in vivo imaging of tissues

Third-harmonic generation microscopy is a powerful label-free nonlinear imaging technique, providing essential information about structural characteristics of cells and tissues without requiring external labelling agents. In this work, we integrated a recently developed compact adaptive optics module into a third-harmonic generation microscope, to measure and correct for optical aberrations in complex tissues. Taking advantage of the high sensitivity of the third-harmonic generation process to material interfaces and thin membranes, along with the 1,300-nm excitation wavelength used here, our adaptive optical third-harmonic generation microscope enabled high-resolution in vivo imaging within highly scattering biological model systems. Examples include imaging of myelinated axons and vascular structures within the mouse spinal cord and deep cortical layers of the mouse brain, along with imaging of key anatomical features in the roots of the model plant Brachypodium distachyon. In all instances, aberration correction led to enhancements in image quality.

60 APPLIED LIFE SCIENCES↗

Role of Defects in Swelling and Creep of Irradiated SiC

Silicon carbide is a promising cladding material because of its high strength and relatively good corrosion resistance. However, SiC is brittle and therefore SiC-based components need to be carefully designed to avoid cracking and failure by fracture. In design of SiC-based composites for nuclear reactor applications it is essential to take into account how mechanical properties are affected by radiation and temperature, or in other words, what strains and stresses develop in this material due to environmental conditions. While thermal strains in SiC can be predicted using classical theories, radiation-induced strains are much less understood. In particular, it is critical to correctly account for radiation swelling and radiation creep, which contribute significantly to dimensional instability of SiC under radiation. Swelling typically increases logarithmically with radiation dose and saturates at relatively low doses (damage levels of a few dpa). Consequently, swelling-induced stresses are likely to develop within a few months of operation of a reactor. Radiation-induced volume swelling in SiC can be as high as 2%, which is significantly higher than the cracking strain of 0.1% in SiC. Swelling-induced strains will lead to enormous stresses and fracture, unless these stresses can be relaxed via some other mechanism. An effective way to achieve stress relaxation is via radiation creep. Although it has been hypothesized that both radiation swelling and radiation creep are driven by formation of defect clusters, existing models for swelling and creep in SiC are limited by the lack of understanding of specific defects that form due to radiation in the range of temperatures relevant to fuel cladding in light water reactors (LWRs) (<1000°C). For example, defects that can be detected with traditional transmission electron microscopy (TEM) techniques account only for 10-45% of the swelling measured in irradiated SiC. Here, we have undertaken an integrated experimental and modeling effort to discover the previously invisible defects in irradiated SiC and to determine the contributions of these defects to radiation swelling. Knowledge of the most stable defect structures and the rate controlling processes during defect evolution is essential for development of predictive models for swelling and creep as a function of temperature and radiation dose. This research has been enabled by state-of-the-art imaging techniques, such as the aberration corrected scanning transmission electron microscopy (STEM) (FEI TITAN) closely coupled with multi-scale models of stable defect clusters and their evolution.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Fast Atomic-Scale Chemical Imaging of Crystalline Materials and Dynamic Phase Transformations

Chemical imaging at the atomic-scale provides a useful real-space approach to chemically investigate solid crystal structures, and has been recently demonstrated in aberration corrected scanning transmission electron microscopy (STEM). Atomic-scale chemical imaging by STEM using energy-dispersive X-ray spectroscopy (EDS) offers easy data interpretation with a one-to-one correspondence between image and structure but has a severe shortcoming due to the poor efficiency of X-ray generation and collection. As a result, it requires a long acquisition time of typical > few 100 seconds, limiting its potential applications. Here we describe the development of an atomic-scale STEM EDS chemical imaging technique that cuts the acquisition time to one or a few seconds, efficiently reducing the acquisition time by more than 100 times. This method was demonstrated using LaAlO 3 (LAO) as a model crystal. Applying this method to the study of phase transformation induced by electron-beam radiation in a layered lithium transition-metal (TM) oxide, i.e., Li[Li 0.2 Ni 0.2 Mn 0.6 ]O 2 (LNMO), a cathode materials for lithium-ion batteries, we obtained a time-series of the atomic-scale chemical imaging, showing the transformation progressing by preferably jumping of Ni atoms from the TM layers into the Li-layers. The new capability offers an opportunity for temporal, atomic-scale chemical mapping of crystal structures for the investigation of materials susceptible to electron irradiation as well as phase transformation and dynamics at the atomic-scale.

36 MATERIALS SCIENCE↗

The effect of hydrogen embrittlement on the localized plastic deformation of aluminum alloy

The effect of hydrogen embrittlement on the localized plastic deformation of aluminum alloy D1 was investigated. The studies were performed for the test samples of aluminum alloy subjected to electrolytic hydrogenation. It is found that the mechanical properties and localized plastic deformation parameters of aluminum alloy are affected adversely by hydrogen embrittlement. The hydrogenated counterpart of alloy has a lower degree of ductility relative to the original alloy; however, the plastic flow behavior of material remains virtually unaffected. Using scanning electron and atomic force microscopy methods, the changes in the fracture surface were investigated. The deformation diagrams were examined for the deformed samples of aluminum alloy. These are found to show all the plastic flow stages: the linear, parabolic and pre-failure stages would occur for the respective values of the exponent n from the Ludwik-Holomon equation. Using digital speckle image technique, the local strain patterns were being registered for the original alloy D1 and the counterpart subjected to electrolytic hydrogenation for 100 h.

36 MATERIALS SCIENCE↗

Submicrometer-Resolution Mapping of Ultraweak 355-nm Absorption in HfO2 Monolayers Using Photothermal Heterodyne Imaging

Nanosecond-pulse UV-laser-damage initiation in multilayer coatings comprised from metal oxide as a high-index component, and silica oxide as a low-index material, is strongly linked to metal oxide. The nature of the absorbing species and their physical properties remain unknown because of extremely small sizes. Previous experimental evidence provided by high-resolution mapping of damage morphology points to a few-nanometer scale of these absorbers. This work demonstrates submicrometer mapping of 355-nm absorption in HfO2 monolayers using a recently developed photothermal heterodyne imaging technique. Comparison of absorption maps with spatial distribution of UV pulsed-laser–induced damage morphology allows one to better estimate the size and densities of nanoscale absorbing defects in hafnia thin films. Possible defect-formation mechanisms are discussed.

laser-induced damage↗

High-DQE EPIDs based on thick, segmented BGO and CsI:Tl scintillators: Performance evaluation at extremely low dose

Purpose: Electronic portal imaging devices (EPIDs) based on active matrix, flat-panel imagers (AMFPIs) have become the gold standard for portal imaging and are currently being investigated for megavoltage cone-beam computed tomography (CBCT) and cone-beam digital tomosynthesis (CBDT). However, the practical realization of such volumetric imaging techniques is constrained by the relatively low detective quantum efficiency (DQE) of AMFPI-based EPIDs at radiotherapy energies, {approx}1% at 6 MV. In order to significantly improve DQE, the authors are investigating thick, segmented scintillators, consisting of 2D matrices of scintillating crystals separated by septal walls. Methods: A newly constructed segmented BGO scintillator (11.3 mm thick) and three segmented CsI:Tl scintillators (11.4, 25.6, and 40.0 mm thick) were evaluated using a 6 MV photon beam. X-ray sensitivity, modulation transfer function, noise power spectrum, DQE, and phantom images were obtained using prototype EPIDs based on the four scintillators. Results: The BGO and CsI:Tl prototypes were found to exhibit improvement in DQE ranging from {approx}12 to 25 times that of a conventional AMFPI-based EPID at zero spatial frequency. All four prototype EPIDs provide significantly improved contrast resolution at extremely low doses, extending down to a single beam pulse. In particular, the BGO prototype provides contrast resolution comparable to that of the conventional EPID, but at 20 times less dose, with spatial resolution sufficient for identifying the boundaries of low-contrast objects. For this prototype, however, the BGO scintillator exhibited an undesirable radiation-induced variation in x-ray sensitivity. Conclusions: Prototype EPIDs based on thick, segmented BGO and CsI:Tl scintillators provide significantly improved portal imaging performance at extremely low dose (i.e., down to 1 beam pulse corresponding to {approx}0.022 cGy), creating the possibility of soft-tissue visualization using MV CBCT and CBDT at clinically practical dose.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Image Analysis Based on Soft Computing and Applied on Space Shuttle During the Liftoff Process

Imaging techniques based on Soft Computing (SC) and developed at Kennedy Space Center (KSC) have been implemented on a variety of prototype applications related to the safety operation of the Space Shuttle during the liftoff process. These SC-based prototype applications include detection and tracking of moving Foreign Objects Debris (FOD) during the Space Shuttle liftoff, visual anomaly detection on slidewires used in the emergency egress system for the Space Shuttle at the laJlIlch pad, and visual detection of distant birds approaching the Space Shuttle launch pad. This SC-based image analysis capability developed at KSC was also used to analyze images acquired during the accident of the Space Shuttle Columbia and estimate the trajectory and velocity of the foam that caused the accident.

Dominquez, Jesus A.↗

Technical Note: Cortical thickness and density estimation from clinical CT using a prior thickness-density relationship

Purpose: Cortical thickness and density are critical components in determining the strength of bony structures. Computed tomography (CT) is one possible modality for analyzing the cortex in 3D. In this paper, a model-based approach for measuring the cortical bone thickness and density from clinical CT images is proposed. Methods: Density variations across the cortex were modeled as a function of the cortical thickness and density, location of the cortex, density of surrounding tissues, and imaging blur. High resolution micro-CT data of cadaver proximal femurs were analyzed to determine a relationship between cortical thickness and density. This thickness-density relationship was used as prior information to be incorporated in the model to obtain accurate measurements of cortical thickness and density from clinical CT volumes. The method was validated using micro-CT scans of 23 cadaver proximal femurs. Simulated clinical CT images with different voxel sizes were generated from the micro-CT data. Cortical thickness and density were estimated from the simulated images using the proposed method and compared with measurements obtained using the micro-CT images to evaluate the effect of voxel size on the accuracy of the method. Then, 19 of the 23 specimens were imaged using a clinical CT scanner. Cortical thickness and density were estimated from the clinical CT images using the proposed method and compared with the micro-CT measurements. Finally, a case-control study including 20 patients with osteoporosis and 20 age-matched controls with normal bone density was performed to evaluate the proposed method in a clinical context. Results: Cortical thickness (density) estimation errors were 0.07 ± 0.19 mm (−18 ± 92 mg/cm{sup 3}) using the simulated clinical CT volumes with the smallest voxel size (0.33 × 0.33 × 0.5 mm{sup 3}), and 0.10 ± 0.24 mm (−10 ± 115 mg/cm{sup 3}) using the volumes with the largest voxel size (1.0 × 1.0 × 3.0 mm{sup 3}). A trend for the cortical thickness and density estimation errors to increase with voxel size was observed and was more pronounced for thin cortices. Using clinical CT data for 19 of the 23 samples, mean errors of 0.18 ± 0.24 mm for the cortical thickness and 15 ± 106 mg/cm{sup 3} for the density were found. The case-control study showed that osteoporotic patients had a thinner cortex and a lower cortical density, with average differences of −0.8 mm and −58.6 mg/cm{sup 3} at the proximal femur in comparison with age-matched controls (p-value < 0.001). Conclusions: This method might be a promising approach for the quantification of cortical bone thickness and density using clinical routine imaging techniques. Future work will concentrate on investigating how this approach can improve the estimation of mechanical strength of bony structures, the prevention of fracture, and the management of osteoporosis.

60 APPLIED LIFE SCIENCES↗

Development of Stochastic Voronoi Lattice Structures via Two-Photon Polymerization

Low-density polymer foams of varying sizes, shapes, and densities are of specific interest to the inertial confinement fusion (ICF) program and related high-energy density plasma physics research. Historically, these foams are comprised of polystyrene or other low atomic number materials and have densities in the 30 to 300 mg/cm 3 range. However, at the lower end of this density range, these traditional polymer foams become fragile and difficult to cast and machine into the geometries needed. Recently, the need by experimentalists for materials with densities below 30 mg/cm 3 has increased. To address these needs, we are developing three-dimensional (3-D) printing techniques to create high-precision, low-density, and repeatable complex lattice structures. Using two-photon polymerization 3-D printing, we recently developed the first 5 mg/cm3 low-density lattice structure having an annular hemispherical shape. These microscale to mesoscale structures were modeled and designed using the nTopology software, specifically utilizing the "Voronoi volume lattice" and "random points in body" option blocks. All printing operations were performed using the Nanoscribe Photonic Professional GT instrument. Characterization of these 3-D structures was conducted using various microscopic and X-ray tomographic imaging techniques. Furthermore, overall printed part sizes ranged from 1 to 5 mm in diameter and were composed of lattice ligaments having thicknesses in the 3- to 5-µm range. These structures have been incorporated into ICF targets recently shot on both the University of Rochester’s Laboratory of Laser Energetics Omega laser and the National Ignition Facility.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Luminescent barometry in wind tunnels

A flexible and relatively inexpensive method and apparatus are described for continuous pressure mapping of aerodynamic surfaces using photoluminescence and imaging techniques. Platinum octaethylporphyrin (PtOEP) has a phosphorescence known to be quenched by oxygen. When dissolved in a silicone matrix, PtOEP may be distributed over a surface as a thin, uniform film. When the film is irradiated with ultraviolet light, the luminescence intensity provides a readily detectable, qualitative surface flow visualization. Moreover, since the luminescence intensity is found to be inversely proportional to the partial pressure of oxygen, a quantitative measure of pressure change may be obtained using a silicon target vidicon or a charge-coupled device video sensor to measure intensity. Luminescent images are captured by a commercial frame buffer board. Images taken in wind tunnels during airflow are ratioed to images taken under ambient 'wind-off' conditions. The resulting intensity ratio information is converted to pressure using calibration curves of I0/I vs p/p0, where I0 is the intensity at ambient pressure p0 and I is the intensity at any other pressure p.

Kavandi, Janet↗

Imaging local luminescence variations in CdSe 0.1 Te 0.9 thin films grown by the colossal grain growth process

Clear visualization and understanding of luminescence properties of grain interiors and grain boundaries in polycrystalline thin-film photovoltaic materials are crucial to achieving high-performance solar cells. Luminescence-based measurements, for example, reveal sub-bandgap energetic disorder or impurity-related radiative transitions in these materials, and when performed in the absolute scale, they can show the extent of voltage-limiting non-radiative recombination. Here we use a hyperspectral imaging technique to investigate inter- and intra-grain photoluminescence variations in polycrystalline CdSe 0.1 Te 0.9 films made by the colossal grain growth process. We observe that grain boundaries show higher luminescence than grain interiors for all energies below the bandgap energy. Multiple distinct sub-bandgap defect transitions are detected and determined to be related to donor-acceptor pair impurities. A comparison of the excitation-intensity-dependent photoluminescence at the grain boundaries with grain interiors suggests that carrier concentration is higher at grain boundaries. This finding is supported by photoemission electron microscopy imaging of the films, showing approximately 70 meV upward energy shift in the band structure at the grain boundaries. Finally, we investigate a dramatic thermal quenching behavior related to the donor-acceptor pairs luminescence over a temperature range and use a rate-equation model to attribute it to the sudden redirection of the radiative recombination channels to non-radiative channels with increasing temperature.

14 SOLAR ENERGY↗

Observation of hydrodynamic plasmons and energy waves in graphene

Thermally excited electrons and holes form a quantum-critical Dirac fluid in ultraclean graphene and their electrodynamic responses are described by a universal hydrodynamic theory. The hydrodynamic Dirac fluid can host intriguing collective excitations distinctively different from those in a Fermi liquid. Here we report the observation of the hydrodynamic plasmon and energy wave in ultraclean graphene. In this study, we use the on-chip terahertz (THz) spectroscopy technique to measure the THz absorption spectra of a graphene microribbon as well as the propagation of the energy wave in graphene close to charge neutrality. We observe a prominent high-frequency hydrodynamic bipolar-plasmon resonance and a weaker low-frequency energy-wave resonance of the Dirac fluid in ultraclean graphene. The hydrodynamic bipolar plasmon is characterized by the antiphase oscillation of massless electrons and holes in graphene. The hydrodynamic energy wave is an electron-hole sound mode with both charge carriers oscillating in phase and moving together. The spatial–temporal imaging technique shows that the energy wave propagates at a characteristic speed of $V_f$ / $ \sqrt2$ near the charge neutrality. Our observations open new opportunities to explore collective hydrodynamic excitations in graphene systems.

36 MATERIALS SCIENCE↗