Search NASA⌕ Search

SEARCH · Search NASA

Results for “Instrument Development”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,009 records · Page 56

Machine-Learning Enabled Evaluation of Probability of Piping Degradation In Secondary Systems of Nuclear Power Plants

The transition to condition-based, risk-informed automated maintenance will contribute to a significant reduction of operations and maintenance costs that account for the majority of nuclear power generation costs. Furthermore, of the operations and maintenance costs in U.S. plants, approximately 80% are labor costs. To address the issue of rising operating costs and economic viability, technologies used to perform online monitoring of piping and other secondary system structural components in commercial nuclear power plants (NPPs) are under evaluation. These online monitoring systems have the potential to identify when a more detailed inspection is needed using real time measurements, rather than at a pre-determined inspection interval thus reducing the maintenance cost. This paper describes distributed high-temperature stable fiber sensors fabricated in optical fibers through a roll-to-roll laser direct writing process using femtosecond lasers. Using phase-sensitive optical time domain reflectometry, distributed acoustic and vibration sensors can be developed and deployed to critical components and systems in NPPs to perform active measurements with spatial resolution down to 0.5-meter throughout the piping systems. Complex acoustic and vibration signatures harnessed by distributed sensors are registered and analyzed by artificial intelligence algorithms for degradation detection and flaw identification. Piping elbows with machined-in flaws were instrumented with fiber sensors. High-spatial-resolution data were used to develop and validate machine learning algorithms, including both linear and nonlinear regression, and classification. Additionally, classification and sensor analysis were also performed for data analysis. The paper concludes with recommendations and future work on applications of machine learning enabled high-resolution fiber sensors for piping degradation monitoring in current or future NPPs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

metabCombiner 2.0: Disparate Multi-Dataset Feature Alignment for LC-MS Metabolomics

Liquid chromatography–high-resolution mass spectrometry (LC-HRMS), as applied to untargeted metabolomics, enables the simultaneous detection of thousands of small molecules, generating complex datasets. Alignment is a crucial step in data processing pipelines, whereby LC-MS features derived from common ions are assembled into a unified matrix amenable to further analysis. Variability in the analytical factors that influence liquid chromatography separations complicates data alignment. This is prominent when aligning data acquired in different laboratories, generated using non-identical instruments, or between batches from large-scale studies. Previously, we developed metabCombiner for aligning disparately acquired LC-MS metabolomics datasets. Here, we report significant upgrades to metabCombiner that enable the stepwise alignment of multiple untargeted LC-MS metabolomics datasets, facilitating inter-laboratory reproducibility studies. To accomplish this, a “primary” feature list is used as a template for matching compounds in “target” feature lists. We demonstrate this workflow by aligning four lipidomics datasets from core laboratories generated using each institution’s in-house LC-MS instrumentation and methods. We also introduce batchCombine, an application of the metabCombiner framework for aligning experiments composed of multiple batches. metabCombiner is available as an R package on Github and Bioconductor, along with a new online version implemented as an R Shiny App.

97 MATHEMATICS AND COMPUTING↗

Development and validation of a humidified CAPS-PMSSA with an improved methodology to calculate the truncation correction factor

Absorbing aerosols play an important role in the Earth’s radiation budget, and current uncertainties associated with their radiative impacts remain substantial. An element of this uncertainty derives from insufficient understanding of the extent to which water, as a coating on absorbing particles, enhances the absorption. Here, we describe and characterize the performance of a cavity-attenuated phase shift single scatter albedo spectrometer (CAPS-PMSSA) system that has been modified to enable concurrent aerosol extinction and scattering measurements, from which aerosol absorption is derived, at relative humidities up to ~90%. The modified instrument is referred to as the humidified CAPS (HCAPS). Additionally, we develop and validate an update to a method to calculate the truncation correction factor, used to correct the scattering measurements, that can account for the effects of particle growth and compositional changes resulting from water uptake. The method can be applied to experiments that use either size-selected or polydisperse aerosol samples of either known or unknown composition. Overall, we show that measurements made with the HCAPS, when processed using the updated truncation correction method, enable accurate measurement of the influence of water uptake on light absorption.

Dal Porto, Rachael [University of California, Davi↗

Assessment of Flow-Enhanced Electrochemical Sensor Testing and Deployments

The goal of our activities in FY24 was to enable advanced materials accountancy for molten salt reactors (MSRs) through the development and optimization of robust flow-enhanced electrochemical sensors (FEES) using a safeguards-focused sensor testing platform called the modular flow instrumentation testbed (MFIT). Flow-enhanced electrochemical sensors are a type of electroanalytical sensor that have been developed at Argonne National Laboratory to be installed directly into MSR flow conduits to make measurements of the salt composition. These sensors represent a significant improvement in capabilities compared to earlier electroanalytical sensors that instead can only be operated in quiescent conditions. Previous work has focused on testing of the FEES in flowing conditions provided by the MFIT to assess the accuracy and precision of the sensor measurements. This year, the FEES technical readiness was increased by (1) demonstrating the use of optimized sensor techniques to achieve measurements in very high-concentration MSR-relevant salts, (2) leveraging new multimodal sensors and automation approaches to reduce measurement uncertainties, and (3) fabricating and deploying sensors to industrial partners to improve their ability to make measurements in challenging environments. Additionally, we also ran the sensors during complex system operations involving combined flow and purification activities to demonstrate safeguards-relevant measurements during online processing for MSRs.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

HOMOLOGOUS SOLAR EVENTS ON 2011 JANUARY 27: BUILD-UP AND PROPAGATION IN A COMPLEX CORONAL ENVIRONMENT

In spite of the wealth of imaging observations at the extreme-ultraviolet (EUV), X-ray, and radio wavelengths, there are still relatively few cases where all of the imagery is available to study the full development of a coronal mass ejection (CME) event and its associated shock. The aim of this study is to contribute to the understanding of the role of the coronal environment in the development of CMEs and the formation of shocks, and their propagation. We have analyzed the interactions of a couple of homologous CME events with ambient coronal structures. Both events were launched in a direction far from the local vertical, and exhibited a radical change in their direction of propagation during their progression from the low corona into higher altitudes. Observations at EUV wavelengths from the Atmospheric Imaging Assembly instrument on board the Solar Dynamic Observatory were used to track the events in the low corona. The development of the events at higher altitudes was followed by the white-light coronagraphs on board the Solar and Heliospheric Observatory . Radio emissions produced during the development of the events were well recorded by the Nançay solar instruments. Thanks to their detection of accelerated electrons, the radio observations are an important complement to the EUV imaging. They allowed us to characterize the development of the associated shocks, and helped to unveil the physical processes behind the complex interactions between the CMEs and ambient medium (e.g., compression, reconnection).

79 ASTRONOMY AND ASTROPHYSICS↗

ROBUST ONLINE MONITORING FOR CALIBRATION ASSESSMENT OF TRANSMITTERS AND INSTRUMENTATION

Robust online monitoring (OLM) technologies are expected to enable the extension or elimination of periodic sensor calibration intervals in operating and new reactors. Specifically, the next generation of OLM technology is expected to include newly developed advanced algorithms that improve monitoring of sensor/system performance and enable the use of plant data to derive information that currently cannot be measured. These advances in OLM technologies will improve the safety and reliability of current and planned nuclear power systems through improved accuracy and increased reliability of sensors used to monitor key parameters. In this paper, we discuss an overview of research being performed within the Nuclear Energy Enabling Technologies (NEET)/Advanced Sensors and Instrumentation (ASI) program, for the development of OLM algorithms to use sensor outputs and, in combination with other available information, 1) determine whether one or more sensors are out of calibration or failing and 2) replace a failing sensor with reliable, accurate sensor outputs. Algorithm development is focused on the following OLM functions: • Signal validation – fault detection and selection of acceptance criteria • Virtual sensing – signal value prediction and acceptance criteria • Response-time assessment – fault detection and acceptance criteria selection A GP-based uncertainty quantification (UQ) method previously developed for UQ in OLM, was adapted for use in sensor-fault detection and virtual sensing. For signal validation, the various components to the OLM residual (which is computed using an AAKR model) were explicitly defined and modeled using a GP. Evaluation was conducted using flow loop data from multiple sources. Results using experimental data from laboratory-scale flow loops indicate that the approach, while capable of detecting sensor drift, may be incapable of discriminating between sensor drift and model inadequacy. This may be due to a simplification applied in the initial modeling, where the sensor degradation is assumed to be stationary. In the case of virtual sensors, the GP model was used in a predictive mode to estimate the correct sensor reading for sensors that may have failed. Results have indicated the viability of using this approach for virtual sensing. However, the GP model has proven to be computationally expensive, and so alternative algorithms for virtual sensing are being evaluated. Finally, automated approaches to performing noise analysis for extracting sensor response time were developed. Evaluation of this technique using laboratory-scale data indicates that it compares well with manual techniques previously used for noise analysis. Moreover, the automated and manual approaches for noise analysis also compare well with the current “gold standard”, hydraulic ramp testing, for response time monitoring. Ongoing research in this project is focused on further evaluation of the algorithms, optimization for accuracy and computational efficiency, and integration into a suite of tools for robust OLM that are applicable to monitoring sensor calibration state in nuclear power plants.

calibration interval extension↗

Biofuels Policies That Have Encouraged Their Production and Use: An International Perspective

This study evaluated the effectiveness of technology-push and market-pull policies in encouraging the production and use of biofuels in 15 countries including major biofuels producers. Biofuels production and consumption data for the 12-year period of 2006-2017 showed that in most of the surveyed countries, biofuels policies played an important role in developing and growing regional and national biofuels markets. Blending mandates continue to be the main market-pull policy used to create and expand biofuels markets. Countries with a mixture of market-pull and technology-push policy instruments have been most successful at increasing biofuels production and use and also developing and deploying less mature advanced biofuels. Most policies have primarily promoted the production and use of biofuels for road transport with key long-distance transport sectors (aviation and shipping) drawing less policy attention despite being significant fuel consumers and carbon emitters. While many older policies were originally developed to promote energy security, more recent policies, such as low carbon fuel standard, have reduction in the carbon intensity of transportation fuels as a primary goal. While policies have been essential in promoting the on-going growth of biofuels, they have not been sufficient to drive the level of development needed to decarbonize the transport sector.

biofuels for transport↗

An ICP-OES method for the precise and accurate quantification of rare earth elements in natural water: A comparative study from mine waste sites in New Mexico, USA

Inductively coupled plasma techniques such as ICP-OES and ICP-MS are routinely used to determine the concentrations of rare earth elements (REE) in water samples. However, their performance for the determination of REE concentration in mine drainage waters from epithermal vein and porphyry copper mining districts has not been evaluated extensively. In this work, we develop an REE analysis method on an Agilent 5900 ICP-OES instrument and assess the accuracy and precision for the quantification of REE in the natural waters collected from mine adits and an acid seep of mine sites in the Steeple Rock and Hillsboro mining districts, New Mexico, USA. The total REE concentrations in the water samples were measured using the methods we developed for both ICP-OES and ICP-MS. The power of the new ICP-OES method lies in routine analysis of μg/L level concentrations normally analyzed using ICP-MS, including a U.S. Geological Survey standard reference sample, laboratory blank samples spiked with a National Institute of Standards and Technology traceable standard, and surface water samples from mine waste sites. This ICP-OES method achieves low quantification limits ranging from 0.2 to 5 μg/L and excellent analytical accuracy and precision for REE analysis. The precision of light (La-Gd) and heavy (Tb-Lu) REE analysis using this method are better than 5% at average concentrations above 5 ± 4 μg/L and 3 ± 2 μg/L, respectively, and 3% at average concentrations above 10 ± 9 μg/L and 5 ± 4 μg/L, respectively. This method also shows excellent sensitivity and reproducibility for our laboratory and field samples.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Advanced Laboratory and Field Arrays (ALFA)/Lab Collaboration Project (LCP) for Marine Energy (Final Scientific/Technical Report)

The objective of the Advanced Laboratory and Field Arrays (ALFA) project was to reduce the Levelized Cost of Energy (LCOE) of Marine and Hydrokinetic (MHK) energy by leveraging research, development, and testing capabilities at Oregon State University, University of Washington, and the University of Alaska, Fairbanks. ALFA is a project within the Pacific Marine Energy Center (PMEC; formerly NNMREC), a multi-institution entity with a diverse funding base that focuses on research and development for marine renewables. The ALFA project aimed to accelerate the development of next-generation arrays of wave energy conversion (WEC) and tidal energy conversion (TEC) devices through a suite of field-focused R&D activities spanning a broad range of strategic opportunity areas identified in the Funding Opportunity Announcement: • Device and/or array operation and maintenance (O&M) logistics development; • High-fidelity resource characterization and/or modeling technique development and validation; • Array-specific component technology development (e.g. moorings and foundations, transmission, and other offshore grid components); • Array performance testing and evaluation; and • Novel cost-effective environmental monitoring techniques and instrumentation testing and evaluation. The objective of the Lab Collaboration Project (LCP) was to accelerate the development of next-generation marine energy conversion systems. The LCP aimed to achieve these project objectives in collaboration with the national laboratories by: • Developing concept generation and assessment tools; • Improving access to existing testing resources; • Validating collision risk models between fish and turbines; and • Advancing analysis and simulation capabilities for wave-WEC interactions and PTO analysis in nonlinear ocean waves. The ALFA portion of the project was comprised of six overarching technical tasks: • Task 1: Debris Modeling, Detection and Mitigation; • Task 2: Autonomous Monitoring & Intervention; • Task 3: Resource Characterization for Extreme Conditions; • Task 4: Robust Models for Design of Offshore Anchoring and Mooring Systems; • Task 5: Performance Enhancement for Marine Energy Converter (MEC) Arrays; and • Task 6: Evaluating Sampling Techniques for MHK Biological Monitoring. The LCP was divided into four overarching technical tasks: • Task 7: Project Management and Reporting • Task 8: Novel Design and Assessment Methodologies for Wave Energy Converter Design (Wave- SPARC) • Task 9: Testing Access for Commercial Marine Renewable Energy Technology Developers • Task 10: Quantifying Collision Risk for Fish and Turbines • Task 11: Nonlinear Ocean Waves and PTO Control Strategy Each ALFA/LCP task listed above functioned as a separate and discreet project. A final Technical Report was written for each individual task and these reports were uploaded to OSTI, after receiving DOE approval. The following document is a compilation of each of these final, approved reports arranged as individual chapters.

13 HYDRO ENERGY↗

In situ synthesis and characterization of uranium carbide using high temperature neutron diffraction

Advances in neutron flux, neutron instrumentation, and sample environments over the past years allowed the development of unique techniques to characterize material synthesis and processing. The available infrastructure at LANL allows to apply these techniques to radioactive materials or materials containing actinides. Here, we present capabilities and results to characterize materials in situ at temperatures above 2000 Celsius degrees such as in loss-of-coolant accidents. Temperatures in excess of 2000 C. degrees are not readily achieved and neutrons are one of a few probes to characterize materials under these conditions. Research in refractory materials, phase diagram studies or accident scenarios for nuclear materials are research areas where such extreme conditions are required. As an example, we present the formation of UC{sub x} from UO{sub 2+x} and graphite in situ using high temperature neutron diffraction with particular focus on resolving the conflicting reports on the crystal structure of non-quenchable cubic UC{sub 2}. The ability to follow the reaction UO{sub 2}+C → UC{sub x}+CO{sub y} in situ with neutron diffraction allows us to conclude that the reaction occurs within minutes over a temperature range of 60 Celsius degrees. The initiation of the reaction is far below the reaction temperature of 2000 C. degrees reported for this reaction in standard text books on actinide chemistry. This may be due to the unusually small ∼100 nm grain size of our UO{sub 2} initial powder. Furthermore, the holding time of several hours reported in the literature would be unnecessary. The neutron diffraction data collected for the cubic high temperature UC{sub 2} phase unambiguously confirmed the disordered C-C dumbbells and excluded structures previously determined by X-ray diffraction.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

StarDICE III: characterization of the photometric instrument with a collimated beam projector

The measurement of Type Ia supernovae magnitudes provides cosmological distances, which constrain dark energy parameters. Current and upcoming large photometric surveys require improved photometric calibration precision to reduce systematic uncertainties in cosmological constraints. The StarDICE experiment aims to establish accurate broad-band flux references for these surveys, targeting sub-percent precision in magnitude measurements. Achieving this requires precise filter bandpass measurements for both StarDICE and survey instruments with sub-nanometre accuracy. To this end, we developed the Collimated Beam Projector (CBP), an optical device for calibrating the throughput of astronomical telescopes and their filters. The CBP uses a tunable laser source and a reversed telescope to emit a parallel monochromatic light beam, continuously monitored in flux and wavelength. The CBP output flux is measured with a large-area photodiode calibrated relative to a NIST photodiode. Using CBP measurements, we derive the StarDICE telescope throughput and filter transmissions, anchoring them to NIST’s absolute calibration. After analysing systematic uncertainties, we achieved sub-nanometre accuracy for filter central wavelengths, measured filter transmission with ~0.5 per cent precision per 1 nm bin, and detected out-of-band leakages at a relative level of 10 –4 ⁠. Furthermore, we synthesized equivalent transmission for full pupil illumination from four sampled positions in the StarDICE telescope mirror, with ~0.2 nm accuracy for central wavelengths and 7 mmag for broad-band fluxes. This demonstrates our ability to characterize telescope throughput down to the millimagnitude, paving the way for future developments, such as the Rubin-CBP for measuring the LSST at Vera Rubin Observatory, and a portable CBP version for in-situ transmission monitoring.

Calibration↗

DOE Energy Frontier Research Centers Center for Direct Catalytic Conversion of Biomass to Biofuels (C3Bio)

New capabilities to predict, design and control the chemistries of carbon could answer a global imperative to transition from fossil-based to sustainable transportation fuels. While the use of inexpensive hydrocarbons has been an unparalleled achievement and enabler of economic prosperity for many nations, singular dependence upon crude oil has given rise to systemic vulnerabilities in climate, energy, economic, and national security. Lignocellulosic biomass, a renewable and carbon-neutral resource, has the potential to displace an estimated annual equivalent of three billion barrels of oil in the U.S. alone (National Research Council 2009, U. S. Department of Energy, 2011). However, biomass has only one-third the energy density of crude oil (Agrawal and Singh 2009, Richard 2010) and lacks petroleum’s versatility as a feedstock for fuels and chemicals. These limitations keep biomass conversion below the efficiency level needed for strategic impact while the scientific challenge of routing carbon from one molecular context to another remains unmet. In 2009, the Center for Direct Catalytic Conversion of Biomass to Biofuels (C3Bio) recognized the potential of chemical catalysis and fast pyrolysis to overcome such limitations by transforming the main components of biomass (cellulose, xylan, and lignin) from grasses and trees directly to liquid hydrocarbons and aromatic co-products. Enabled by the EFRC high-risk, high-reward approach to grand challenge science, C3Bio researchers have been key national players in disrupting the conventional paradigm of the cellulosic biorefinery into a new future of “no carbon left behind”—the full utilization of carbon from plant cell walls in energy-dense fuels (Fig. 1). We identified catalytic and fast-pyrolytic pathways that utilize cellulose, xylan and, most significantly, lignin. We developed catalytic processes that deoxygenate and transform monomers and isolated polymers into useful products and tested their use with intact biomass. We gained control of lignin synthesis within plants and initiated tailoring biomass to its end-use through the tools of plant molecular biology and genetic engineering. C3Bio breakthroughs have increased the energy density of biomass-derived substrates via catalytic and pyrolytic conversions into products such as benzoquinones, furfural and hydroxymethylfurfural, levoglucosan and levulinic acid, methoxypropylphenols and propylbenzene. Such advances in biomass conversion would not have been possible without simultaneous advances in analytical instrumentation and methodologies, and imaging technologies and applications. The legacy science developed by C3Bio enables design and control strategies for achieving a targeted product portfolio of fuel and chemical feedstocks from a diverse range of native and tailored biomass. Our research provides the knowledge base required for a bio-economy with product streams as diverse in functionality as those of the petrochemical industry. Coupling targeted computational modeling with experimentation, we achieved: (1) fundamental understanding of biopolymers and cell wall architecture assembly, (2) discovery of new chemistries that allow the development of highly selective pathways to fuels and desirable chemicals, and (3) an integrated systems-level understanding to control catalytic and pyrolytic pathways.

09 BIOMASS FUELS↗

High Intensity Gamma Ray Source Scintillation Attenuation Spectrometer and Filter Stack Monoenergetic Calibration

The Laser-Based X-ray Radiographic Imaging team at Los Alamos National Lab is looking for a monoenergetic MeV X-ray source to both verify our Monte Carlo N-particle simulations of detector performance and calibrate the instruments for future measurements. Funded by the Laboratory Directed Research and Development (LDRD) program, our overall goal is to improve the radiographic quality and reliability of laser-based X-ray sources for deployment at both dynamic and static radiography facilities. Laser-based X-ray sources have demonstrated smaller spot sizes to current electron accelerator based sources. The smaller laser spot size leads to significantly improved resolution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Handheld Biosensor for COVID-19 Screening

We have made significant progress toward the development of an integrated nucleic acid amplification system for Autonomous Medical Devices Incorporated (AMDIs) Optikus handheld diagnostic device. In this effort, we developed a set of loop-mediated isothermal amplification (LAMP) primers for SARS-CoV-2 and then demonstrate amplification directly on a surface acoustic wave (SAW) sensor. We built associated hardware and developed a C-code to control the amplification process. The goal of this project was to develop a nucleic amplification assay that is compatible with SAW sensors to enable both nucleic and serological testing in a single handheld diagnostic device. Toward this goal, AMDI is collaborating Sandia National Laboratories to develop a rapid, portable diagnostic screening device that utilizes Sandias unique surface acoustic wave biosensor (SAW) for COVID-19 detection. Previously, the SANDIA- AMDI SAW sensor has successfully detected multiple high-profile bacteria viruses, including Ebola, HIV, Sin Nombre, and Anthrax. Over the last two years, AMDI and SANDIA have significantly improved the sensitivity and detection capability of the SAW biosensor and have also developed a modular hand-held, portable platform called the Optikus, which uses CD microfluidics and handheld instrumentation to automate all sample preparation, reagent introduction, sample delivery, and measurement for a number of different assay targets. We propose to use this platform for the development of a rapid (%3C30 minutes), point-of-care diagnostic test for detection of COVID-19 from nasal swab samples.

47 OTHER INSTRUMENTATION↗

Comparison of Sub-Ppm Instrument Response Suggests Higher Detection Limits Could Be Used to Quantify Methane Emissions from Oil and Gas Infrastructure

Quantifying and controlling fugitive methane emissions from oil and gas facilities remains essential for addressing climate goals, but the costs associated with monitoring millions of production sites remain prohibitively expensive. Current thinking, supported by measurement and simple dispersion modelling, assumes single-digit parts-per-million instrumentation is required. To investigate instrument response, the inlets of three trace-methane (sub-ppm) analyzers were collocated on a facility designed to release gas of known composition at known flow rates between 0.4 and 5.2 kg CH 4 h –1 from simulated oil and gas infrastructure. Methane mixing ratios were measured by each instrument at 1 Hertz resolution over nine hours. While mixing ratios reported by a cavity ring-down spectrometer (CRDS)-based instrument were on average 10.0 ppm (range 1.8 to 83 ppm), a mid-infrared laser absorption spectroscopy (MIRA)-based instrument reported short-lived mixing ratios far larger than expected (range 1.8 to 779 ppm) with a similar nine-hour average to the CRDS (10.1 ppm). We suggest the peaks detected by the MIRA are likely caused by a micrometeorological phenomenon, where vortex shedding has resulted in heterogeneous methane plumes which only the MIRA can observe. Further analysis suggests an instrument like the MIRA (an optical-cavity-based instrument with cavity size ≤10 cm3 measuring at ≥2 Hz with air flow rates in the order of ≤0.3 slpm at distances of ≤20 m from the source) but with a higher detection limit (25 ppm) could detect enough of the high-concentration events to generate representative 20 min-average methane mixing ratios. Even though development of a lower-cost, high-precision, high-accuracy instrument with a 25 ppm detection threshold remains a significant problem, this has implications for the use of instrumentation with higher detection thresholds, resulting in the reduction in cost to measure methane emissions and providing a mechanism for the widespread deployment of effective leak detection and repair programs for all oil and gas infrastructure.

03 NATURAL GAS↗

FRIB Project Status and Beam Instrumentation Challenges

With an average beam power two orders of magnitude higher than operating heavy-ion facilities, the Facility for Rare Isotope Beams (FRIB) stands at the power frontier of the accelerator family. This report summarizes the status of design, technology development, construction, commissioning, as well as path to operations and upgrades. We also highlight beam instrumentation challenges including machine protection of high-power heavy-ion beams and complications of multi-charge-state and multi-ion-species accelerations.

43 PARTICLE ACCELERATORS↗

The DESI instrument control systems: status and early testing

The Dark Energy Spectroscopic Instrument (DESI) is a new instrument currently under construction for the Mayall 4-m telescope at Kitt Peak National Observatory. It will consist of a wide-field optical corrector with a 3.2 degree diameter field of view, a focal plane with 5,000 robotically controlled fiber positioners and 10 fiber-fed broad-band spectrographs. The DESI Instrument Control System (ICS) coordinates fiber positioner operations, interfaces to the Mayall telescope control system, monitors operating conditions, reads out the 30 spectrograph CCDs and provides observer support and data quality monitoring. In this paper, we summarize the ICS design, review the current status of the project and present results from a multi-stage test plan that was developed to ensure the system is fully operational by the time the instrument arrives at the observatory in 2019.

79 ASTRONOMY AND ASTROPHYSICS↗