Simulation of degradation of coal organic matter

The existing procedures for calculating thermodynamic functions of individual compounds of coal organic matter were analyzed, and possible reactions of its degradation were simulated. The possibility of the occurrence of pyrolysis reactions in the forward direction with the formation of methane, propane, and other saturated hydrocarbons as target products was examined by calculation of the Gibbs energies using an additive procedure for determining the thermodynamic functions of structural fragments and data on the composition of coal from Kuznetsk coal fields. The chemical and thermodynamic relationships between the starting compounds and pyrolysis products were examined, and the temperature intervals of the reactions were determined.

01 COAL, LIGNITE, AND PEAT↗

Precise measurement of $2νββ$ decay of $^{100}$Mo with the CUPID-Mo detection technology

We report the measurement of the two-neutrino double-beta ($2\nu\beta\beta$) decay of $^{100}$Mo to the ground state of $^{100}$Ru using lithium molybdate (\crystal) scintillating bolometers. The detectors were developed for the CUPID-Mo program and operated at the EDELWEISS-III low background facility in the Modane underground laboratory. From a total exposure of $42.235$ kg$\times$d, the half-life of $^{100}$Mo is determined to be $T_{1/2}^{2\nu}=[7.12^{+0.18}_{-0.14}\,\mathrm{(stat.)}\pm0.10\,\mathrm{(syst.)}]\times10^{18}$ years. This is the most accurate determination of the $2\nu\beta\beta$ half-life of $^{100}$Mo to date. We also confirm, with the statistical significance of $>3\sigma$, that the single-state dominance model of the $2\nu\beta\beta$ decay of $^{100}$Mo is favored over the high-state dominance model.

01 COAL, LIGNITE, AND PEAT↗

Corrosion Behavior of Steels in Supercritical CO 2 for Power Cycle Applications

In order to understand issues with corrosion of heat exchanger materials in direct supercritical carbon dioxide (sCO 2 ) power cycles, a series of autoclave exposure experiments and electrochemical experiments have been conducted. Corrosion behaviors of 347H stainless steel and P91 martensitic-ferrtic steel in sCO 2 environment have been compared. In autoclave exposure tests performed at 50°C- 245°C and 80 bar. Mass change measurements, surface characterization, and corrosion product analysis have been conducted to understand the corrosion behavior of steels in sCO 2 containing H 2 O and O 2 . Electrochemical tests performed at room temperature and 50°C, a simulation environment of water condensation phase with dissolved CO 2 was prepared to evaluate the corrosion resistance of materials. From both types of experiments, generally 347H showed higher corrosion resistance than P91.

01 COAL, LIGNITE, AND PEAT↗

Corrosion protection mechanism of polyaniline blended organic coating on steel

Epoxy-coal tar coatings are widely used to protect steel structures exposed to marine atmosphere due to their good barrier property. However, the presence of micropores and microcracks formed during the coating formation leads to failure of the coating due to permeation of corrosive ions. In recent years, it has been established that the coatings containing polyaniline (PANI) is able to protect pinholes and defects due to its passivating ability. Hence, a study has been made on the effect of polyaniline content (1 and 3%) in epoxy-coal tar coating on the corrosion protection of steel in 3% NaCl solution by electrochemical impedance spectroscopy (EIS) studies. Both phosphate- and chloride-doped polyanilines were prepared by a chemical oxidative polymerization method. From EIS studies, it has been found that the resistance value of the coatings containing 1 and 3% phosphate-doped polyaniline and 3% chloride-doped polyaniline pigmented coatings are similar to 10{sup 9} {Omega} cm{sup 2} even after 90 days exposure to NaCl solution, which are two orders high in comparison to that of conventional coal tar epoxy coatings. Besides, the conducting state of polyaniline has been found to be decreased after exposure to NaCl solution due to redox property of PANI. X-ray photoelectron spectroscopy studies have shown that polyaniline forms a complex layer with iron beneath the coating along with iron oxide.

01 COAL, LIGNITE, AND PEAT↗

Hydrogen production using solid oxide membrane electrolyzer with solid carbon reductant in liquid metal anode

A laboratory-scale solid oxide membrane (SOM) steam electrolyzer that can potentially utilize the energy value of coal or any hydrocarbon reductant to produce high purity hydrogen has been fabricated and evaluated. The SOM electrolyzer consists of an oxygen-ion-conducting yttria-stabilized zirconia (YSZ) electrolyte with a Ni-YSZ cermet cathode coated on one side and liquid tin anode on the other side. Hydrogen production using the SOM electrolyzer was successfully demonstrated between 900 and 1000{sup o}C by feeding a steam-rich gas to the Ni-YSZ cermet cathode and solid carbon reductant into the liquid tin anode. It was confirmed that the energy required for hydrogen production can be effectively lowered by feeding a solid carbon reductant in the liquid tin anode. A polarization model for the SOM electrolyzer was developed. The experimental data obtained under different operating conditions were curve fitted into the model to identify the various polarization losses. Based on the results of this study, work needed toward increasing the electrochemical performance of the SOM electrolyzer is discussed.

01 COAL, LIGNITE, AND PEAT↗

Ni/YSZ Anode Interactions with Impurities in Coal Gas

Performance of solid oxide fuel cell (SOFC) with nickel/zirconia anodes on synthetic coal gas in the presence of low levels of phosphorus, arsenic, selenium, sulfur, hydrogen chloride, and antimony impurities were evaluated. The presence of phosphorus and arsenic led to the slow and irreversible SOFC degradation due to the formation of secondary phases with nickel, particularly close to the gas inlet. Phosphorus and antimony surface adsorption layers were identified as well. Hydrogen chloride and sulfur interactions with the nickel were limited to the surface adsorption only, whereas selenium exposure also led to the formation of nickel selenide for highly polarized cells.

01 COAL, LIGNITE, AND PEAT↗

Effect of simulated coal-derived gas composition on H{sub 2}S poisoning behavior evaluated using a disaggregation scheme

H{sub 2}S poisoning is an important issue for solid oxide fuel cells (SOFCs) operated with syngas. The effect of simulated coal-derived gas composition on H{sub 2}S poisoning behavior was evaluated using a disaggregation scheme where the influence of H{sub 2} content was determined separately using a typical anode-supported SOFC operated with a N2/H{sub 2} mixture gas, while the effect of other compositions (CO, CO{sub 2}, and H{sub 2}O) was investigated with simulated coal-derived gas having constant H{sub 2} and CO flow rates balanced by a H{sub 2}/N2 mixture gas (83% H{sub 2} and 17% N2). The results indicated that the extent of H{sub 2}S poisoning was not pertinent to H{sub 2} content when the cell was tested galvanostatically with a current density of 0.3 A/cm{sup 2} at 800{sup o}C using a N2/H{sub 2} mixture gas containing 10 ppm H{sub 2}S, and the H{sub 2}S poisoning impact can be completely removed by switching to sulfur-free gas. The CO, CO{sub 2}, and high water vapor content aggravated the H{sub 2}S poisoning effect, and the performance was almost irrecoverable when the cell was tested with a 35% H{sub 2}-46% CO-16% N2-3% H{sub 2}O mixture gas containing 12.5 ppm H{sub 2}S. However, the introduction of 10% CO{sub 2} and an increase in H{sub 2}O content from 3 to 10% in the mixture gas can promote the performance recoverability to a larger extent.

01 COAL, LIGNITE, AND PEAT↗

SOFC Ohmic Resistance Reduction by HCl-Induced Removal of Manganese at the Anode/Electrolyte Interface

The ohmic resistance of anode-supported solid oxide fuel cells having a manganese-based cathode was lowered when operated in synthetic coal gas containing hydrogen chloride. This effect was not observed for cells with cathodes that did not contain manganese. Substantial amounts of Mn were found throughout the grain boundaries of the 8 mole% yttria-stabilized zirconia (8YSZ) electrolyte. Exposure to HCl partially removed Mn near the anode/electrolyte interface, presumably by volatilization as MnCl2(g). This work suggests that one of the underlying causes of higher than expected electrolyte resistance in anode-supported SOFCs is a lowering of the ionic conductivity of 8YSZ by incorporation of manganese.

01 COAL, LIGNITE, AND PEAT↗

Polarization-Induced Interfacial Reactions between Nickel and Selenium in Ni/Zirconia SOFC Anodes and Comparison with Sulfur Poisoning

Three distinctly different characteristic responses of a nickel/yttria-stabilized zirconia (Ni/YSZ) cermet anode to the presence of hydrogen selenide in synthetic coal gas were observed, depending on temperature (650-800oC), H2Se concentration (0-40 ppm), and especially on the extent of anodic polarization (0 to ~0.5 V). The first level of response was characterized by a rapid but modest decrease in power density to a new steady state, with no further degradation observed in tests up to 700 hours in duration. Mostly observed at high temperatures, low H2Se concentrations, and low anodic polarizations, this response level was similar to effects caused by the presence of H2S, but with slower onset and lower reversibility. Higher anodic polarization at a constant current could trigger a second level of response characterized by oscillatory behavior involving cycles of rapid performance loss followed by rapid recovery. Oscillations at the constant current density were accompanied by the appearance and disappearance of a new feature in the electrochemical impedance spectrum with a summit frequency of ~100 Hz. Oscillatory behavior ceased when the current density was lowered. Such behavior was not observed for cells operated at a constant potential of similar magnitude, though. A third level of response, irreversible cell failure, could be induced by further increases in anodic polarization, additionally favored by low temperature and high H2Se concentration. Post-test analyses of failed cells by electron microscopy revealed the extensive microstructural changes including the appearance of nickel oxide and nickel selenide alteration phases, only at the anode/electrolyte interface. From bulk thermochemical considerations the formation of nickel selenides could not be expected. Local chemical conditions created at the anode/electrolyte interface appear to be of overriding importance with respect to the extent of Ni/YSZ anode interactions with H2Se in coal gas.

01 COAL, LIGNITE, AND PEAT↗

Fireside corrosion in oxy-fuel combustion of coal

Oxy-fuel combustion is based on burning fossil fuels in a mixture of recirculated flue gas and oxygen, rather than in air. An optimized oxy-combustion power plant will have ultra-low emissions since the flue gas that results from oxy-fuel combustion consists almost entirely of CO2 and water vapor. Once the water vapor is condensed, it is relatively easy to sequester the CO2 so that it does not escape into the atmosphere. A variety of laboratory tests comparing air-firing to oxy-firing conditions, and tests examining specific simpler combinations of oxidants, were conducted at 650-700 C. Alloys studied included model Fe-Cr and Ni-Cr alloys, commercial ferritic steels, austenitic steels, and nickel base superalloys. Furthermore, the observed corrosion behavior shows accelerated corrosion even with sulfate additions that remain solid at the tested temperatures, encapsulation of ash components in outer iron oxide scales, and a differentiation between oxy-fuel combustion flue gas recirculation choices.

01 COAL, LIGNITE, AND PEAT↗

Aryl hydrocarbon receptor expression is associated with a family history of upper gastrointestinal tract cancer in a high-risk population exposed to aromatic hydrocarbons

Polycyclic aromatic hydrocarbon (PAH) exposure is a risk factor for esophageal squamous cell carcinoma, and PAHs are ligands of the aryl hydrocarbon receptor (AhR). This study measured the expression of AhR and related genes in frozen esophageal cell samples from patients exposed to different levels of indoor air pollution, who did or did not have high-grade squamous dysplasia and who did or did not have a family history of upper gastrointestinal tract (UGI) cancer. 147 samples were evaluated, including 23 (16%) from patients with high-grade dysplasia and 48 (33%) from patients without dysplasia who heated their homes with coal, without a chimney (a 'high' indoor air pollution group), and 27 (18%) from patients with high-grade dysplasia and 49 (33%) from patients without dysplasia who did not heat their homes at all (a 'low' indoor air pollution group). Sixty-four (44%) had a family history of UGI cancer. RNA was extracted and quantitative PCR analysis was done. AhR gene expression was detectable in 85 (58%) of the samples and was >9-fold higher in those with a family history of UGI cancer (median expression (interquartile range), -1,964 (-18,000, -610) versus -18,000 (-18,000, -1036); P = 0.02, Wilcoxon rank-sum test). Heating status, dysplasia category, age, gender, and smoking were not associated with AhR expression (linear regression; all P values {ge} 0.1). AhR expression was higher in patients with a family history of UGI cancer. Such individuals may be more susceptible to the deleterious effects of PAH exposure, including PAH-induced cancer.

01 COAL, LIGNITE, AND PEAT↗

Contributions of dust exposure and cigarette smoking to emphysema severity in coal miners in the United States

Previous studies have shown associations between dust exposure or lung burden and emphysema in coal miners, although the separate contributions of various predictors have not been clearly demonstrated. The objective was to quantitatively evaluate the relationship between cumulative exposure to respirable coal mine dust, cigarette smoking, and other factors on emphysema severity. The study group included 722 autopsied coal miners and nonminers in the United States. Data on work history, smoking, race, and age at death were obtained from medical records and questionnaire completed by next-of-kin. Emphysema was classified and graded using a standardized schema. Job-specific mean concentrations of respirable coal mine dust were matched with work histories to estimate cumulative exposure. Relationships between various metrics of dust exposure (including cumulative exposure and lung dust burden) and emphysema severity were investigated in weighted least squares regression models. Emphysema severity was significantly elevated in coal miners compared with nonminers among ever- and never-smokers (P < 0.0001). Cumulative exposure to respirable coal mine dust or coal dust retained in the lungs were significant predictors of emphysema severity (P < 0.0001) after accounting for cigarette smoking, age at death, and race. The contributions of coal mine dust exposure and cigarette smoking were similar in predicting emphysema severity averaged over this cohort. Coal dust exposure, cigarette smoking, age, and race are significant and additive predictors of emphysema severity in this study.

01 COAL, LIGNITE, AND PEAT↗

Synthesis and characterization of carbon-encapsulated magnetic nanoparticles via arc-plasma assisted CVD

Carbon-encapsulated magnetic nanoparticles (CEMNs) were fabricated on a large scale by arc-plasma assisted CVD in acetylene. The coal-derived metal-containing (Fe, Co and Ni) carbon rods were used as anodes, while a high-purity graphite rod was used as a cathode that remained unchanged during the arcing process. The CEMNs obtained were characterized by TEM, XRD, Raman spectroscopy, N{sub 2} adsorption isotherms and VSM. The diameter distribution of the obtained CEMNs varies from 10 to 70 nm, of which the metal cores are proximately 5-50 nm. The core phases in Fe ) nanoparticles are body-centered cubic Fe and orthorhombic Fe3C while Co ) nanoparticles and Ni ) nanoparticles show the characteristic of a face-centered cubic structure. The Fe ), Co ) and Ni ) nanoparticles with well-ordered graphitic shells have the surface area of 89 m{sup 2}/g, 72 m{sup 2}/g and 75 m{sup 2}/g, respectively. The CEMNs show ferromagnetic of which was characterized by a ratio of remnant magnetization (MR) to saturation magnetization (MS).

01 COAL, LIGNITE, AND PEAT↗

King Coal vs. Reclamation: federal regulation of mountaintop removal mining in Appalachia

This research focuses on the regulatory politics of mountaintop removal mining for coal within the Appalachian states of West Virginia and Kentucky. Based on Administrative Presidency concepts suggesting that chief executives seek more control and influence over agency program decisions, this article analyzes President George W. Bush's efforts to promote the development of coal resources within these states despite statutory constraints posed by federal environmental laws. The analysis demonstrates that President Bush effectively achieved his energy production goals by combining the use of discretionary authority with staff controls, executive orders, and regulatory initiatives to lessen industry compliance costs with environmental regulatory requirements.

01 COAL, LIGNITE, AND PEAT↗

Boiler Corrosion and Monitoring

Results of a collaborative effort to investigate and develop solutions for key material issues affecting the performance of large-scale coal-fired boilers operating at advanced conditions is presented. Advanced conditions include advanced steam temperatures, oxyfuel firing, and co-firing biomass materials. A series of laboratory experimental results are presented on fireside corrosion in environments representing air-, and oxy-fired conditions, and with coal and/or biomass as the fuel. The effects of fluctuating reducing atmospheres and heat flux effects were examined. A variety of boiler corrosion probes and sensors were developed and tested. The probes measured corrosion by section loss and the sensors by electrochemical techniques including electrochemical noise. The probes were tested in coal and waste-to-energy boilers. Correlations between section loss probes and electrochemical noise sensors allow for real-time corrosion rate measurements to be made that allow for changes in boiler operations to be tracked in terms of corrosion effects.

01 COAL, LIGNITE, AND PEAT↗

Gravity monitoring of CO{sub 2} movement during sequestration: Model studies

Sequestration/enhanced oil recovery (EOR) petroleum reservoirs have relatively thin injection intervals with multiple fluid components (oil, hydrocarbon gas, brine, and carbon dioxide, or CO{sub 2}), whereas brine formations usually have much thicker injection intervals and only two components (brine and CO{sub 2}). Coal formations undergoing methane extraction tend to be thin (3-10 m) but shallow compared to either EOR or brine formations. Injecting CO{sub 2} into an oil reservoir decreases the bulk density in the reservoir. The spatial pattern of the change in the vertical component of gravity (G{sub z}) is correlated directly with the net change in reservoir density. Furthermore, time-lapse changes in the borehole G{sub z} clearly identify the vertical section of the reservoir where fluid saturations are changing. The CO{sub 2}-brine front, on the order of 1 km within a 20-m-thick brine formation at 1900-m depth with 30% CO{sub 2} and 70% brine saturations, respectively, produced a -10-{mu} Gal surface gravity anomaly. Such an anomaly would be detectable in the field. The amount of CO{sub 2} in a coal-bed methane scenario did not produce a large enough surface gravity response; however, we would expect that for an industrial-size injection, the surface gravity response would be measurable. Gravity inversions in all three scenarios illustrate that the general position of density changes caused by CO{sub 2} can be recovered but not the absolute value of the change. Analysis of the spatial resolution and detectability limits shows that gravity measurements could, under certain circumstances, be used as a lower-cost alternative to seismic measurements.

01 COAL, LIGNITE, AND PEAT↗