Search NASA⌕ Search

SEARCH · Search NASA

Results for “Layout”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,009 records · Page 56

LAFD: TA-16 HE Facility Familiarization Tour, OJT 55258

Los Alamos National Laboratory (LANL) will conduct familiarization tours for personnel of the Los Alamos County Fire Department (LAFD) at TA-16 high explosives (HE) facilities. These familiarization tours are official LANL business; the purpose of these tours is to orient LAFD firefighters to the facility so that they can respond efficiently and quickly to a variety of emergency situations. This orientation includes, among other topics, ingress and egress of the area and buildings, layout and organization of the facility, evacuation procedures and assembly points, and areas of concern within the various buildings at the facility. LAFD firefighters have the skills and abilities to perform firefighting operations and other emergency response tasks that cannot be provided by LANL personnel who have the required clearance. This handout provides details of the information, along with maps and diagrams, to be presented during the familiarization tours. The handout will be distributed to the trainees at the time of the tour. A corresponding checklist will also be used as guidance during the familiarization tours to ensure that all required information is presented to LAFD personnel.

99 GENERAL AND MISCELLANEOUS↗

Assessing and Testing Hydrokinetic Turbine Performance and Effects on Open Channel Hydrodynamics: An Irrigation Canal Case Study.

Hydrokinetic energy from flowing water in open channels has the potential to support local electricity needs with lower regulatory or capital investment than impounding water with more conventional means. MOU agencies involved in federal hydropower development have identified the need to better understand the opportunities for hydrokinetic (HK) energy development within existing canal systems that may already have integrated hydropower plants. This document provides an overview of the main considerations, tools, and assessment methods, for implementing field tests in an open-channel water system to characterize current energy converter (CEC) device performance and hydrodynamic effects. It describes open channel processes relevant to their HK site and perform pertinent analyses to guide siting and CEC layout design, with the goal of streamlining the evaluation process and reducing the risk of interfering with existing uses of the site. This document outlines key site parameters of interest and effective tools and methods for measurement and analysis with examples drawn from the Roza Main Canal, in Yakima, WA to illustrate a site application.

13 HYDRO ENERGY↗

Uranium Enrichment Safeguards

DIV of facility layout, material flows, and other information provided in the DIQ. Material accountancy through an annual PIV and a number of interim inventory verifications, including UF6 cylinder identification and counting, NDA of cylinders, and DA on a sample collection of UF6. Application of C/S technologies utilizing seals and tamper-indicating devices (TIDs) on cylinders, containers, storage rooms, and IAEA instrumentation to provide continuity of knowledge between inspection. Verification of the absence of undeclared material and operations, especially HEU production, through SNRIs, LFUA of cascade halls, and environmental swipe sampling

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Los Alamos County Fire Department LAFD: TA-55 PF-4 Facility Familiarization Tour, OJT 55260

Los Alamos National Laboratory (LANL) will conduct familiarization tours for Los Alamos County Fire Department (LAFD) personnel at the Plutonium Facility (PF-4) at Technical Area (TA)-55. These familiarization tours are official LANL business; the purpose of these tours is to orient the firefighters to the facility so that they can respond efficiently and quickly to a variety of emergency situations. This orientation includes the ingress and egress of the area and buildings, layout and organization of the facility, evacuation procedures and assembly points, and areas of concern within the various buildings at the facility. LAFD firefighters have the skills and abilities to perform firefighting operations and other emergency response tasks that cannot be provided by other LANL personnel who have the required clearance level. This handout provides details of the information, along with maps and diagrams, to be presented during the familiarization tours. The handout will be distributed to the trainees at the time of the tour. A corresponding checklist will also be used as guidance during the familiarization tours to ensure that all required information is presented to LAFD personnel.

99 GENERAL AND MISCELLANEOUS↗

FleCSPH notes

FleCSI is a compile-time con gurable framework designed to support multi-physics application development. As such, FleCSI provides a very general set of infrastructure design patterns that can be specialized and extended to suit the needs of a broad variety of solver and data requirements. FleCSI currently supports multi-dimensional mesh topology, geometry, and adjacency information, as well as n-dimensional hashed-tree data structures, graph partitioning interfaces, and dependency closures. FleCSI introduces a functional programming model with control, execution, and data abstractions that are consistent both with MPI and with state-of-the-art, task-based runtimes such as Legion and Charm++. The abstraction layer insulates developers from the underlying runtime, while allowing support for multiple runtime systems including conventional models like asynchronous MPI. The intent is to provide developers with a concrete set of user-friendly programming tools that can be used now, while allowing exibility in choosing runtime implementations and optimization that can be applied to future architectures and runtimes. FleCSI's control and execution models provide formal nomenclature for describing poorly understood concepts such as kernels and tasks. FleCSI's data model provides a low-buy-in approach that makes it an attractive option for many application projects, as developers are not locked into particular layouts or data structure representations. FleCSI currently provides a parallel but not distributed implementation of Binary, Quad and Oct-tree topology. This implementation is base on space lling curves domain decomposition, the Morton order. The current FleCSI version requires the implementation of a driver and a specialization driver. The role of the specialization driver is to provide the data distribution. This feature is not complete in FleCSI code and we provide it. The next step will be to incorporate it directly from FleCSPH to FleCSI as we reach a good level of performance. Then the driver represent the general execution of the resolution without worrying of the data locality and communications. As FleCSI is an On-Development code the structure may change in the future and we keep track of these changes in FleCSPH.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

LAFD: TA-55 RLUOB/CUB Facility Familiarization Tour, OJT #55265

Los Alamos National Laboratory (LANL) conducts familiarization tours for personnel of the Los Alamos County Fire Department (LAFD) at the RLUOB/CUB, technical area (TA)-55, 400/440, facility, Radiological Laboratory Utility Office Building (RLUOB)/Central Utility Building (CUB). These familiarization tours are official LANL business; the purpose of these tours is to orient LAFD firefighters to the facility so that they can respond efficiently and quickly to a variety of emergency situations. This orientation includes, among other topics, the ingress and egress of the area and buildings, layout and organization of the facility, evacuation procedures and assembly points, and areas of concern within the various buildings at the facility. LAFD firefighters have the skills and abilities to perform firefighting operations and other emergency response tasks that cannot be provided by other LANL personnel who have the required clearance level. This handout provides details of the information, along with maps and diagrams, to be presented during the familiarization tours. The handout is distributed to the trainees at the time of the tour; a corresponding checklist is also used as guidance during the familiarization tours to ensure that all required information is presented to LAFD personnel.

99 GENERAL AND MISCELLANEOUS↗

Resilient and Robust High Performance Computing Platforms for Scientific Computing Integrity

As technology advances, computer systems are subject to increasingly sophisticated cyber-attacks that compromise both their security and integrity. High performance computing platforms used in commercial and scientific applications involving sensitive, or even classified data, are frequently targeted by powerful adversaries. This situation is made worse by a lack of fundamental security solutions that both perform efficiently and are effective at preventing threats. Current security solutions fail to address the threat landscape and ensure the integrity of sensitive data. As challenges rise, both private and public sectors will require robust technologies to protect its computing infrastructure. The research outcomes from this project try to address all these challenges. For example, we present LAZARUS, a novel technique to harden kernel Address Space Layout Randomization (KASLR) against paging-based side-channel attacks. In particular, our scheme allows for fine-grained protection of the virtual memory mappings that implement the randomization. We demonstrate the effectiveness of our approach by hardening a recent Linux kernel with LAZARUS, mitigating all of the previously presented side-channel attacks on KASLR. Our extensive evaluation shows that LAZARUS incurs only 0.943% overhead for standard benchmarks, and is therefore highly practical. We also introduced HA2lloc, a hardware-assisted allocator that is capable of leveraging an extended memory management unit to detect memory errors in the heap. We also perform testing using HA2lloc in a simulation environment and find that the approach is capable of preventing common memory vulnerabilities.

97 MATHEMATICS AND COMPUTING↗

LAFD: TA-3 NISC & SCC Facility Familiarization Tour, OJT #53356

Los Alamos National Laboratory (LANL, the Laboratory, or the Lab) conducts familiarization tours for Los Alamos County Fire Department (LAFD) personnel at the Strategic Computing Complex (SCC), TA-03-2327, and the Nonproliferation & International Security Complex (NISC), TA-03-2322. These tours are official LANL business; their purpose is to orient the firefighters to the SCC and the NISC so that they can respond efficiently and quickly to a variety of emergency situations. The tour includes ingress and egress of the buildings, layout and organization of the buildings, evacuation procedures, and areas of concern to emergency responders within these buildings. LAFD firefighters have the training, skills, and abilities to perform these emergency responder tasks; other LANL personnel who have the required clearance level cannot perform these tasks. This handout provides details of the information, along with maps and diagrams, to be presented during the familiarization tours. The report will be distributed to the trainees at the time of the tour. A corresponding checklist will also be used as guidance during the familiarization tours to ensure that all required information is presented to the LAFD personnel.

99 GENERAL AND MISCELLANEOUS↗

Radiological Protection Studies for NGLS XTOD

The X-ray transport, optics and diagnostic system (XTOD) starts from the end of bending magnets sending electrons to the main dump and ends at the end wall separating the accelerator tunnel from the user experimental hall (hereafter referred as EH wall), as shown in Figure 1. Figure 1.a shows the general schematic and Figure 1.b shows the initial layout with possible shielding components. This document summarizes the extensive studies on the shielding and collimator system design necessary to meet the radiation protection requirements.

61 RADIATION PROTECTION AND DOSIMETRY↗

LAFD: TA-55 General Facility Familiarization Tour, Course #55261

Los Alamos National Laboratory (LANL) will conduct familiarization tours for personnel of the Los Alamos County Fire Department (LAFD) at the TA-55 General Facility. These familiarization tours are official LANL business; the purpose of these tours is to orient LAFD firefighters to the facility so that they can respond efficiently and quickly to a variety of emergency situations. This orientation includes, among other topics, ingress and egress of the area and buildings, layout and organization of the facility, evacuation procedures and assembly points, and areas of concern within the various buildings at the facility. LAFD firefighters have the skills and abilities to perform firefighting operations and other emergency response tasks that cannot be provided by LANL personnel who have the required clearance level. This handout provides details of the information, along with maps and diagrams, to be presented during the familiarization tours. The handout will be distributed to the trainees at the time of the tour. A corresponding checklist will also be used as guidance during the familiarization tours to ensure that all required information is presented to LAFD personnel.

99 GENERAL AND MISCELLANEOUS↗

Spallation Neutron Source Second Target Station Integrated Systems Update

The Spallation Neutron Source (SNS) was designed from the beginning to accommodate both an accelerator upgrade to increase the proton power and a second target station (STS). Four workshops were organized in 2013 and 2014 to identify key science areas and challenges where neutrons will play a vital role [1-4]. Participants concluded that the addition of STS to the existing ORNL neutron sources was needed to complement the strengths of High Flux Isotope Reactor (HFIR) and the SNS first target station (FTS). To address the capability gaps identified in the workshops, a study was undertaken to identify instrument concepts that could provide the required new science capabilities. The study outlined 22 instrument concepts and presented an initial science case for STS [5]. These instrument concepts formed the basis of a planning suite of instruments whose requirements determined an initial site layout and moderator selection. An STS Technical Design Report (TDR) documented the STS concept based on those choices [6]. Since issue of the TDR, the STS concept has significantly matured as described in this document.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Use of Fiber Optic Distributed Acoustic Sensing for Measuring Hydraulic Connectivity for Geothermal Applications

Advanced methods in reservoir characterization are required to effectively harness geothermal energy from fractured high-temperature, high-pressure crystalline rock. It is critical to determine sufficient fluid connection between injection and production wells to enhance sweep efficiency and optimize the lifetime of the reservoir. A technology is needed that can monitor hydraulic connectivity in real time at any depth in the reservoir, throughout the lifetime of the reservoir. GeoMechanics Technologies, in collaboration with California State University, Long Beach (CSULB) and Silixa LLC, working in cooperation with the Department of Energy, Small Business Innovation Research through DOE SBIR Grant No: DE-SC-0017744, conducted a Phase I research project to investigate the use of fiber optic Distributed Acoustic Sensing (DAS) to improve geothermal reservoir characterization. Fiber optic DAS technology uses inter-well pressure sensing in response to periodic injection to determine hydraulic connectivity in fractured geothermal reservoirs. Fiber optic technology is capable of withstanding high temperatures and pressures typical of geothermal reservoirs. This tool would provide nearly continuous pressure monitoring along the length of the wellbore, providing knowledge into hydraulic pathways even where perforations do not exist. Real-time hydraulic monitoring can be performed without interrupting normal field operations. Also, measurements can be obtained throughout the lifetime of the well, ideally accounting for any changes in operations or reservoir configurations or thermally induced changes in permeability. The objective of this research effort was to develop and document an innovative tool that can be used for geothermal reservoir characterization. GeoMechanics Technologies and partners investigated and documented the use of fiber optic DAS for measuring the hydromechanical response caused by fractures in a reservoir and how that correlates to reservoir connectivity. For this Phase I project, numerical simulations, laboratory testing, and a field demonstration were performed to further validate the effectiveness of DAS technology for detecting formation hydraulics. This report summarizes the project activities. The main significant findings are: 1. From the numerical simulations using conceptual models, it is concluded that a high permeability zone inside a reservoir shows a different strain pattern along vertical monitoring lines away from the injection, when inducing low frequency pressure pulses. 2. The order of magnitude of strain observed at a distance of 100 ft from the injection well ranged from nanostrain to microstrain. Such strains are detectable with DAS tools currently available to industry. 3. Laboratory experiments stressed the importance of cable design and layout in the field, making calibration on site necessary for each application individually. 4. Field comparison highlighted the operational conditions that play a role in adding noise to the DAS measurement, where temperature effects for this type of application are also considered as noise to the strain measurements. 5. The analyses conducted to date provide motivation for further research, development and application of this technology, combined with field testing.

15 GEOTHERMAL ENERGY↗

Survey Draft

A procedure is described and methods which yield toward alignment of positions of all CBETA components within their tolerances. Major principles governing survey and alignment measurement space are briefly shown and their relationship to a lattice coordinate system. Then a discussion of the activities involved in a step-by-step sequence from initial layout to final alignment is described. In the vertical plane, the curvature of the earth does not need to be considered as the dimensions of the whole CBETA project are to small, The leveling is done with respect to gravity.

43 PARTICLE ACCELERATORS↗

Low-noise, radiation tolerant SiCpms

Over the last 10 years, our R&D effort has resulted in a steady progress on improving Geiger detector array technology performance, verifying their reliability and developing three cell layout libraries containing more than 2200 primitive cells for Si and SiC Geiger based single-photon detectors and silicon ROIC array fabrication. Awards from DOE, NASA and DOD, as wells as commercial R&D orders supported much progress, relevant to this program. The expertise gained and the technologies developed or qualified during these programs provided the design database and expertise to carry out the development of this new SiC photomultiplier (SiCpm) technology, successful fabrication of SiCpm detectors, and evaluation of their radiation hardness. After irradiation with protons and neutrons at 1015cm-2 and 1014cm-2 respectively, SiCpms proved radiation hardness, exceeding the expected radiation tolerance The defects induced by irradiation were mainly point defects. A new improved DLTS method (fDLTS – full wave DLTS) hardware and data processing software specific to investigating radiation damage in SiC was developed. Further work is needed to better characterize and control defects induced by charged particles. We recommend further funding of radiation hardened technology development and validation; qualification of device-specific characterization methods like f-DLTS, development of more methods to evaluate defects in SiC, more active involvement of the national labs in evaluating the SiCpm devices, and DOE support of technology transfer to a qualified foundry.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Accident Scenarios for IOTA Ring and Dose Distributions Calculated with MARS15 Code

The Integrable Optics Test Accelerator (IOTA) at Fermilab’s Accelerator Science and Technology (FAST) facility [1] is a storage ring for advanced high intensity beam physics research. Layout of the ring is shown in Fig. 1. A plan view of the ring with enclosure walls are shown in Fig. 2. The entire beam, stored in the IOTA ring, is assumed to be completely lost at either of the three locations shown in Fig. 2. Therefore, we will consider three separate corresponding accident scenarios. The maximal amount of electrons stored in the IOTA ring is estimated to be 2×10 10 electrons with energy of 150 MeV. At locations 1 and 2 the beam is lost on 60-deg dipole walls, while at location 3 the beam is lost on Lambertson magnet wall.

43 PARTICLE ACCELERATORS↗

Parameters and Tolerances for the Booster Dipole Power Supplies

In this technical note we discuss the parameters and tolerances for the booster dipole power supplies. We first discuss the requirements on the current ramp profile for the cases of energy ramps at 1 and 2 Hz. Then we determine the voltage waveforms that correspond to these current ramps. Using the booster magnet lattice and the actual power supply circuit layouts we then calculate the orbit distortion and tune spread caused by the magnetic field amplitude errors in the combined-function dipole magnets at the time of injection and extraction and establish the requirements on the value of the magnetic field amplitude errors at these points along the ramp. We then conclude the note by translating these requirements into the amplitude and time tolerances for the dipole power supplies.

42 ENGINEERING↗

Comparison of conventional vs. modular hydrogen refueling stations, and on-site production vs. delivery

To meet the needs of public and private stakeholders involved in the development, construction, and operation of hydrogen fueling stations needed to support the widespread roll-out of hydrogen fuel cell electric vehicles, this work presents publicly available station templates and analyses. These 'Reference Stations' help reduce the cost and speed the deployment of hydrogen stations by providing a common baseline with which to start a design, enable quick assessment of potential sites for a hydrogen station, identify contributors to poor economics, and suggest areas of research. This work presents layouts, bills of materials, piping and instrumentation diagrams, and detailed analyses of five new station designs. In the near term, delivered hydrogen results in a lower cost of hydrogen compared to on-site production via steam methane reforming or electrolysis, although the on-site production methods have other advantages. Modular station concepts including on-site production can reduce lot sizes from conventional assemble-on-site stations.

08 HYDROGEN↗

Building 1090 Boil-Off Exhaust Modifications 90% Basis of Design

This document provides analysis and proposed modifications to correct current issues at Building 1090. Electrical modifications will add additional emergency Iighting in Labs 170, 174, 178, 182, 184, 186, and 190, and back-up power for the exhaust systems, fume hood lighting and exhaust system controls during a power outage. Mechanical modifications will address building pressurization between the lab and office areas, and replacement of corroded exhaust ductwork and fume hoods related to boil-off operations of corrosive chemicals. Mechanical modifications include the installation of a dedicated, chemical boil-off exhaust fan and ductwork to support corrosive boil-off operations in Lab 184. It should be noted that the proposed solution increases the overall building exhaust demand, also increasing the supply air needed. Electrical modifications include the installation of an uninterruptible power supply (UPS) to provide power to the exhaust fan, controls, and fume hoods to allow safe exit from Laboratory 186 during a power outage. The existing lighting inverter will also be replaced with a larger model to support additional emergency lighting within the labs. Architectural modifications include exterior doors on the east wall of the IDR room. An additional door in the corridor west of Lab 184 will provide direct access to Lab 186 without entering a common building corridor. Lab casework will be modified as-required to accommodate the new layout.

42 ENGINEERING↗