Search NASA⌕ Search

SEARCH · Search NASA

Results for “Linear response”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,009 records · Page 56

Observation of broken inversion and chiral symmetries in the pseudogap phase in single- and double-layer bismuth-based cuprates

We deduce the symmetry of the pseudogap phase in the single- and double-layer bismuth-based cuprate superconductors, where charge and pseudogap order onset concurrently, by measuring and analyzing their circular and linear photogalvanic responses, which are related linearly to the chirality and inversion breaking, respectively, of the order parameter. After separating out the trivial contribution arising from the surface where inversion symmetry is already broken, we show that both responses start below the pseudogap temperature T* and grow below it to a sizable magnitude, revealing the broken symmetries in the bulk of the crystal. Through a detailed analysis of the dependence of the signals on the angle of incidence, the polarization of the light, and the orientation of the crystal, we are able to discover that the point group symmetry below T* is limited to mm2 or mm21– groups. Here, taking into account formation of domains and previous measurements, our results narrow down the possible symmetries of the microscopic origin of the phase transition(s) at T*, which leads to the conclusion that while charge order may affect the observed symmetry it is not the main cause of the pseudogap order parameter.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Covariant constitutive relations and relativistic inhomogeneous plasmas

The notion of a 2-point susceptibility kernel used to describe linear electromagnetic responses of dispersive continuous media in nonrelativistic phenomena is generalized to accommodate the constraints required of a causal formulation in spacetimes with background gravitational fields. In particular the concepts of spatial material inhomogeneity and temporal nonstationarity are formulated within a fully covariant spacetime framework. This framework is illustrated by recasting the Maxwell-Vlasov equations for a collisionless plasma in a form that exposes a 2-point electromagnetic susceptibility kernel in spacetime. This permits the establishment of a perturbative scheme for nonstationary inhomogeneous plasma configurations. Explicit formulae for the perturbed kernel are derived in both the presence and absence of gravitation using the general solution to the relativistic equations of motion of the plasma constituents. In the absence of gravitation this permits an analysis of collisionless damping in terms of a system of integral equations that reduce to standard Landau damping of Langmuir modes when the perturbation refers to a homogeneous stationary plasma configuration. It is concluded that constitutive modeling in terms of a 2-point susceptibility kernel in a covariant spacetime framework offers a natural extension of standard nonrelativistic descriptions of simple media and that its use for describing linear responses of more general dispersive media has wide applicability in relativistic plasma modeling.

97 MATHEMATICS AND COMPUTING↗

Simulating dielectric spectra: A demonstration of the direct electric field method and a new model for the nonlinear dielectric response

Here we demonstrate a method to compute the dielectric spectra of fluids in molecular dynamics (MD) by directly applying electric fields to the simulation. We obtain spectra from MD simulations with low magnitude electric fields (≈0.01 V/Å) in agreement with spectra from the fluctuation–dissipation method for water and acetonitrile. We examine this method’s trade-off between noise at low field magnitudes and the nonlinearity of the response at higher field magnitudes. We then apply the Booth equation to describe the nonlinear response of both fluids at low frequency (0.1 GHz) and high field magnitude (up to 0.5 V/Å). We develop a model of the frequency-dependent nonlinear response by combining the Booth description of the static nonlinear dielectric response of fluids with the frequency-dependent linear dielectric response of the Debye model. We find good agreement between our model and the MD simulations of the nonlinear dielectric response for both acetonitrile and water.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

SU-G-BRB-14: Uncertainty of Radiochromic Film Based Relative Dose Measurements

Purpose: Due to inherently non-linear dose response, measurement of relative dose distribution with radiochromic film requires measurement of absolute dose using a calibration curve following previously established reference dosimetry protocol. On the other hand, a functional form that converts the inherently non-linear dose response curve of the radiochromic film dosimetry system into linear one has been proposed recently [Devic et al, Med. Phys. 39 4850–4857 (2012)]. However, there is a question what would be the uncertainty of such measured relative dose. Methods: If the relative dose distribution is determined going through the reference dosimetry system (conversion of the response by using calibration curve into absolute dose) the total uncertainty of such determined relative dose will be calculated by summing in quadrature total uncertainties of doses measured at a given and at the reference point. On the other hand, if the relative dose is determined using linearization method, the new response variable is calculated as ζ=a(netOD)n/ln(netOD). In this case, the total uncertainty in relative dose will be calculated by summing in quadrature uncertainties for a new response function (σζ) for a given and the reference point. Results: Except at very low doses, where the measurement uncertainty dominates, the total relative dose uncertainty is less than 1% for the linear response method as compared to almost 2% uncertainty level for the reference dosimetry method. The result is not surprising having in mind that the total uncertainty of the reference dose method is dominated by the fitting uncertainty, which is mitigated in the case of linearization method. Conclusion: Linearization of the radiochromic film dose response provides a convenient and a more precise method for relative dose measurements as it does not require reference dosimetry and creation of calibration curve. However, the linearity of the newly introduced function must be verified. Dave Lewis is inventor and runs a consulting company for radiochromic films.

07 ISOTOPE AND RADIATION SOURCES↗

SU-E-T-65: Characterization of a 2D Array for QA and Pretreatment Plan Verification

Purpose: The OCTAVIUS detector729 is a 2D array of 729 air vented cubic plane parallel ion chambers used for pretreatment verification and QA. In this study we investigated dosimetric characteristics of this system for clinical photon beam dosimetry. Methods: Detector performance evaluation included determination of the location of the effective point of measurement (EPM), sensitivity, linearity, and reproducibility of detector response, as well as output factor, dose rate, and source to surface distance (SSD) dependence. Finally, assessment of wedge modulated fields was carried out. All the evaluations were performed five times for low and high photon energies. For reference measurements, a 0.6 cc ionization chamber was used. Data analysis and comparison of the OCTAVIUS detector with reference ion chamber data was performed using the VeriSoft patient plan verification software. Results: The reproducibility and stability of the measurements are excellent, the detector showed same signal with a maximum deviation of less than 0.5% in short and long term. Results of sensitivity test showed same signal with a maximum deviation of approximately 0.1%. As the detector 729 response is linear with dose and dose rate, it can be used for the measurement at regions of high dose gradient effectively. The detector agrees with the ionization chamber measurement to within 1% for SSD range of 75 to 125 cm. Also, its measured wedge modulated profiles matched very well with ion chamber dose profiles acquired in a water tank. Conclusions: As the response of the detector 729 is linear with dose and dose rate, it can be used for the measurements in the areas of dose gradients effectively. Based on the measurements and comparisons performed, this system is a reliable and accurate dosimeter for QA and pretreatment plan verification in radiotherapy.

60 APPLIED LIFE SCIENCES↗

Induction of Chromosomal Aberrations at Fluences of Less Than One HZE Particle per Cell Nucleus

The assumption of a linear dose response used to describe the biological effects of high LET radiation is fundamental in radiation protection methodologies. We investigated the dose response for chromosomal aberrations for exposures corresponding to less than one particle traversal per cell nucleus by high energy and charge (HZE) nuclei. Human fibroblast and lymphocyte cells where irradiated with several low doses of <0.1 Gy, and several higher doses of up to 1 Gy with O (77 keV/ (long-s)m), Si (99 keV/ (long-s)m), Fe (175 keV/ (long-s)m), Fe (195 keV/ (long-s)m) or Fe (240 keV/ (long-s)m) particles. Chromosomal aberrations at first mitosis were scored using fluorescence in situ hybridization (FISH) with chromosome specific paints for chromosomes 1, 2 and 4 and DAPI staining of background chromosomes. Non-linear regression models were used to evaluate possible linear and non-linear dose response models based on these data. Dose responses for simple exchanges for human fibroblast irradiated under confluent culture conditions were best fit by non-linear models motivated by a non-targeted effect (NTE). Best fits for the dose response data for human lymphocytes irradiated in blood tubes were a NTE model for O and a linear response model fit best for Si and Fe particles. Additional evidence for NTE were found in low dose experiments measuring gamma-H2AX foci, a marker of double strand breaks (DSB), and split-dose experiments with human fibroblasts. Our results suggest that simple exchanges in normal human fibroblasts have an important NTE contribution at low particle fluence. The current and prior experimental studies provide important evidence against the linear dose response assumption used in radiation protection for HZE particles and other high LET radiation at the relevant range of low doses.

Hada, Megumi↗

Computationally Efficient Frequency Domain Method for Dynamic Control Derivative Estimation with Application to Transonic Truss-Braced Wing

This paper presents a computationally efficient method for dynamic control derivative estimation technique via control surface oscillation numerical experiments. Unsteady RANS CFD simulations in FUN3D are performed to simulate the control surface oscillations with a prescribed truncated square wave containing sufficient frequencies of interest. The truncated square wave oscillation offers the computational efficiency which reduces the computational cost by almost an order of magnitude compared to a sine wave oscillation. The nonlinear effect of large control surface oscillation amplitudes creates a spillover effect whereby the frequency response at the same input frequencies contains not only the linear aerodynamic response but also nonlinear aerodynamic response. A correction procedure is developed to remove the spillover effect from the linear aerodynamic response. A frequency-domain regression is performed to estimate the dynamic control derivatives after the correction. The results generally agree with the previous results obtained from the sine wave oscillation.

Stability and Control↗

Some implications of linear-quadratic-linear radiation dose-response with regard to hypofractionation

Recent technological advances enable radiation therapy to be delivered in a highly conformal manner to targets located almost anywhere in the body. This capability has renewed the clinical interest in hypofractionation wherein the tumor is delivered a few fractions of very large dose per fraction. Extrapolating clinical experience from conventional regimens to fractions of high dose is important to designing hypofractionated treatments. The concept of biologically effective dose (BED) based on the linear-quadratic (LQ) formulation e{sup -({alpha}D+{beta}D{sup 2})} is a useful tool for intercomparing conventional fractionations but may be hampered if the value of {alpha}/{beta} is dose range dependent and/or when extrapolating to fractions of high dose because the LQ curve bends continuously on the log-linear plot. This does not coincide with what is observed experimentally in many clonogenic cell survival studies at high dose wherein radiation dose-response relationships more closely approximate a straight line. Intercomparison of conventional fractionations with hypofractionated regimens may benefit from BED calculations which instead use a dose range independent linear-quadratic-linear (LQ-L) formulation which better fits the experimental data across a wider range of dose. The dosimetric implications of LQ-L are explored using a simple model which requires only the specification of a dose D{sub T} at which the LQ curve transitions to final linearity and the log{sub e} cell kill per Gy in the final linear portion of the survival curve at high dose. It is shown that the line tangent to the LQ curve at transition dose D{sub T} can often be used to approximate the final slope of the dose response curve. When D{sub T}=2{alpha}/{beta} Gy, the line tangent to the LQ curve at D{sub T} intersects the e{sup -{alpha}}{sup D} and e{sup -{beta}}{sup D{sup 2}} curves at dose {alpha}/{beta} Gy and also closely fits the linear response in the high dose region of some classic in vitro cell survival curves for which the value of {alpha}/{beta} is low. It is hypothesized that D{sub T} will increase as the magnitude of {alpha}/{beta} increases. Examples are presented illustrating how to recognize LQ-L behavior in multifraction isoeffect studies of late responses such as spinal cord and lung. When planning hypofractionated regimens involving reactions with low {alpha}/{beta}, recognizing LQ-L behavior could be important because the dose-response is likely to transition to final linearity within the contemplated range of hypofractional doses.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

User document for computer programs for ring-stiffened shells of revolution

A user manual and related program documentation is presented for six compatible computer programs for structural analysis of axisymmetric shell structures. The programs apply to a common structural model but analyze different modes of structural response. In particular, they are: (1) Linear static response under asymmetric loads; (2) Buckling of linear states under asymmetric loads; (3) Nonlinear static response under axisymmetric loads; (4) Buckling nonlinear states under axisymmetric (5) Imperfection sensitivity of buckling modes under axisymmetric loads; and (6) Vibrations about nonlinear states under axisymmetric loads. These programs treat branched shells of revolution with an arbitrary arrangement of a large number of open branches but with at most one closed branch.

Cohen, G. A.↗

Linear and nonlinear optical responses in the chiral multifold semimetal RhSi

Chiral topological semimetals are materials that break both inversion and mirror symmetries. They host interesting phenomena such as the quantized circular photogalvanic effect (CPGE) and the chiral magnetic effect. In this work, we report a comprehensive theoretical and experimental analysis of the linear and nonlinear optical responses of the chiral topological semimetal RhSi, which is known to host multifold fermions. We show that the characteristic features of the optical conductivity, which display two distinct quasi-linear regimes above and below 0.4 eV, can be linked to excitations of different kinds of multifold fermions. The characteristic features of the CPGE, which displays a sign change at 0.4 eV and a large non-quantized response peak of around 160 μA/V 2 at 0.7 eV, are explained by assuming that the chemical potential crosses a flat hole band at the Brillouin zone center. Our theory predicts that, in order to observe a quantized CPGE in RhSi, it is necessary to increase the chemical potential as well as the quasiparticle lifetime. More broadly, our methodology, especially the development of the broadband terahertz emission spectroscopy, could be widely applied to study photogalvanic effects in noncentrosymmetric materials and in topological insulators in a contact-less way and accelerate the technological development of efficient infrared detectors based on topological semimetals.

Materials Science↗

Rotor blade aeroelastic stability and response in forward flight

The aeroelastic stability and response problem of the coupled flap-lag-torsional dynamics of a hingeless rotor blade in forward flight is treated in a comprehensive manner. The spatial dependence of the partial differential, nonlinear, equations of motion is discretized using a multimodal Galerkin method. The aeroelastic problem is coupled with the trim state of the helicopter obtained from improved, representative, trim procedures. The nonlinear time dependent equilibrium position, or response, about which the equations are linearized is obtained by solving a sequence of linear periodic response problems, using quasi-linearization. Numerous results illustrating blade behavior in forward flight are presented.

Friedmann, P. P.↗

Non-axisymmetric equilibrium and stability using the ELITE stability code

Linear perturbation theory is used to model the ideal magnetohydrodynamic stability of tokamak equilibria under the application of external 3D magnetic perturbations. We use the ELITE code to produce both a linear plasma response, as well as the linear axisymmetric toroidal eigenmodes which are used as basis functions for the 3D perturbative stability analysis. In this work, the symmetry breaking produces coupling of modes with different toroidal mode number, n, leading to modification of the linear growth rates, and poloidal localisation of the nonaxisymmetric peeling–ballooning mode at sufficiently large applied field.

3D MHD stability↗

Dynamic Tensile Characterization of Hiperco 50A Alloy at Various Strain Rates and Temperatures

Soft ferromagnetic alloys are often utilized in electromagnetic applications due to their desirable magnetic properties. In support of these applications, the ferromagnetic alloys are also desired to bear mechanical load at various environmental temperatures. In this study, a Permendur 2V alloy manufactured by Metalwerks Inc. (but referred to Hiperco 50A, a trademark of Carpenter Technologies Inc.) was dynamically characterized in tension with a Kolsky tension bar and a Dropkinson bar at various strain rates and temperatures. Dynamic tensile stress-strain curves of the Hiperco 50A alloy were obtained at the strain rates ranging from 40 to 230 s -1 and temperatures from -100 to 100°C. All tensile stress-strain curves exhibited an initial linear elastic response to an upper yield followed by a Eiders banding response and then a nearly linear work-hardening behavior. The yield strength of this material was found to be sensitive to both strain rate and temperature; whereas, the hardening rate was independent of strain rate or temperature. The Hiperco 50A alloy exhibited a feature of brittle fracture in tension under dynamic loading with no necking being observed.

36 MATERIALS SCIENCE↗

Comparisons of linear and nonlinear plasma response models for non-axisymmetric perturbations

With the installation of non-axisymmetric coil systems on major tokamaks for the purpose of studying the prospects of ELM-free operation, understanding the plasma response to the applied fields is a crucial issue. Application of different response models, using standard tools, to DIII-D discharges with applied non-axisymmetric fields from internal coils, is shown to yield qualitatively different results. The plasma response can be treated as an initial value problem, following the system dynamically from an initial unperturbed state, or from a nearby perturbed equilibrium approach, and using both linear and nonlinear models [A. D. Turnbull, Nucl. Fusion 52, 054016 (2012)]. Criteria are discussed under which each of the approaches can yield a valid response. In the DIII-D cases studied, these criteria show a breakdown in the linear theory despite the small 10{sup −3} relative magnitude of the applied magnetic field perturbations in this case. For nonlinear dynamical evolution simulations to reach a saturated nonlinear steady state, appropriate damping mechanisms need to be provided for each normal mode comprising the response. Other issues arise in the technical construction of perturbed flux surfaces from a displacement and from the presence of near nullspace normal modes. For the nearby equilibrium approach, in the absence of a full 3D equilibrium reconstruction with a controlled comparison, constraints relating the 2D system profiles to the final profiles in the 3D system also need to be imposed to assure accessibility. The magnetic helicity profile has been proposed as an appropriate input to a 3D equilibrium calculation and tests of this show the anticipated qualitative behavior.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Dosimetric properties of an amorphous-silicon EPID used in continuous acquisition mode for application to dynamic and arc IMRT

Dosimetric properties of an amorphous-silicon electronic portal imaging device (EPID) operated in a real-time acquisition mode were investigated. This mode will be essential for time-resolved dose verification of dynamic (sliding window) intensity modulated radiation therapy (IMRT) and intensity modulated arc radiation therapy (arc-IMRT). The EPID was used in continuous acquisition mode (i.e., ''cine'' mode) where individual sequential image frames are acquired in real time. The properties studied include dose linearity, reproducibility of response, and image stability. Results of using the continuous acquisition mode with several example treatments including dynamic IMRT, arc treatment, and single-arc-IMRT are compared to results using the well-studied integrated acquisition mode (i.e., ''frame averaging'' or ''IMRT'' mode). Real-time EPID response was also compared to real-time ion-chamber data for selected points in the deliveries. The example treatment deliveries in both continuous and integrated acquisition modes were converted to arbitrary EPID dose units via a calibration field. The summation of all acquired continuous mode images was compared using percentage dose difference to the single image acquired in the integrated mode using in-field pixels only (defined as those pixels >10% of maximum, in-field signal). Using the continuous acquisition mode, the EPID response was not linear with dose. It was found that the continuous mode dose response corresponded approximately to dropping one image per acquisition session. Reproducibility of EPID response to low monitor units (MUs) was found to be poor but greatly improved with increasing MU. Open field profiles were found to be stable in the cross-plane direction but required several frames to become stable in the in-plane direction. However, both of these issues are clinically insignificant due to arc-IMRT deliveries requiring relatively large monitor units (>100 MU). Analysis of the five IMRT, arc, and arc-IMRT tests revealed that all examples compared to within 2% of maximum dose for more than 95% of in-field pixels. The continuous acquisition mode is suited to time-resolved dosimetry applications including arc-IMRT and dynamic IMRT, giving comparable dose results to the well-studied integrated acquisition mode, although caution should be used in low MU applications. Time-resolved EPID dose information also compared well to time-resolved ion-chamber measurements.

61 RADIATION PROTECTION AND DOSIMETRY↗