At least 1,009 records · Page 56

Mitigating the impact of the DESI fiber assignment on galaxy clustering

In this paper, we present a simple strategy to mitigate the impact of an incomplete spectroscopic redshift galaxy sample as a result of fiber assignment and survey tiling. The method has been designed for the Dark Energy Spectroscopic Instrument (DESI) galaxy survey but may have applications beyond this. We propose a modification to the usual correlation function that nulls the almost purely angular modes affected by survey incompleteness due to fiber assignment. Predictions of this modified statistic can be calculated given a model of the two point correlation function. The new statistic can be computed with a slight modification to the data catalogues input to the standard correlation function code and does not incur any additional computational time. Lastly, we show that the spherically averaged baryon acoustic oscillation signal is not biased by the new statistic.

79 ASTRONOMY AND ASTROPHYSICS↗

Power System Resilience Considering Hurricane Storms and Generator Step-up Transformers

Power system resilience describes the system’s ability to withstand and recover quickly from unexpected power outages due to extreme events. As society’s electrification continues at a rapid rate, it is imperative electric infrastructure is designed and operated with extra security. This work studies the impact of severe hurricane storms on the power system located along the United States’ Eastern Seaboard. Specific focus is designated to steady state system operation and loss of large generation step up power transformers. A series of phasor domain power system simulations are conducted to determine the critical point at which the system loses steady state operability. Additionally, active power load shedding and generator dispatching are studied as mitigation and recovery strategies. Results indicate generator dispatching as an effective proactive mitigation strategy and load shedding as an effective recovery strategy.

Liu, Yilu↗

Wellbore Leakage Mitigation Using Advanced Mineral Precipitation Strategies (Final Scientific/Technical Report)

This research project, entitled Wellbore Leakage Mitigation using Advanced Mineral Precipitation Strategies, was directed toward advancing mineral precipitation technologies to seal wellbore leaks and other potential carbon dioxide (CO 2 ) leakage pathways, including compromised wellbore cement and fracture networks of varying geometries throughout the wellbore and surrounding formation. The advanced mineral sealing techniques were evaluated in the laboratory and the field to expand the range of temperature, pressure, and chemical conditions where mineral precipitation could be used. Rates of enzymatically or thermally induced calcium carbonate precipitation (EICP, TICP) were determined as well as rates of enzyme inactivation at elevated temperatures (>60 °C). Immobilization was shown to enhance the thermal stability of urease enzyme and provide protection from inhibition in low pH conditions. Mineral seals promoted by EICP and TICP were used to seal fractured composite (cement/sandstone) and shale cores in high pressure reactors operated at temperatures greater than 55 °C and 130 °C, respectively. A computational model was updated to model processes of EICP and TICP. The work resulted in a successful field test, which showed that EICP in the presence of low pH fluids (CO 2 -impacted brine) could promote permeability reduction and seal a channel in the near-wellbore environment.

54 ENVIRONMENTAL SCIENCES↗

Poster — Thur Eve — 41: Considerations for Patients with Permanently Implant Radioactive Sources Requiring Unrelated Surgery

Permanent implant of sealed radioactive sources is an effective technique for treating cancer. Typically, the radioactive sources are implanted in and near the disease, depositing dose locally over several months. There may be instances where these patients must undergo unrelated surgical procedures when the radioactive material remains active enough to pose risks. This work explores these risks, discusses strategies to mitigate those risks, and describes a case study for a permanent I-125 prostate brachytherapy implant patient who developed colo-rectal cancer and required surgery 6 months after brachytherapy. The first consideration is identifying the risk from unwarranted radiation to the patient and staff before, during, and after the surgical procedure. The second is identifying the risk the surgical procedure may have on the efficacy of the brachytherapy implant. Finally, there are considerations for controlling for radioactive substances from a regulatory perspective. After these risks are defined, strategies to mitigate those risks are considered. These strategies may include applying the concepts of ALARA, the use of protective equipment and developing a best practice strategy with the operating room team. We summarize this experience with some guidelines: If the surgical procedure is near (ex: 5 cm) of the implant; and, the surgical intervention may dislodge radioisotopes enough to compromise treatment or introduces radiation safety risks; and, the radioisotope has not sufficiently decayed to background levels; and, the surgery cannot be postponed, then a detailed analysis of risk is advised.

60 APPLIED LIFE SCIENCES↗

Nanoscale Protection Layers To Mitigate Degradation in High-Energy Electrochemical Energy Storage Systems

In the pursuit of energy storage devices with higher energy and power, new ion storage materials and high-voltage battery chemistries are of paramount importance. Yet, they invite—and often enhance—degradation mechanisms, which are reflected in capacity loss with charge/discharge cycling and sometimes in safety problems. Degradation mechanisms are often driven by fundamentals such as chemical and electrochemical reactions at electrode–electrolyte interfaces, volume expansion and stress associated with ion insertion and extraction, and profound inhomogeneity of electrochemical behavior. Although it is important to identify and understand these mechanisms at some reasonable level, it is even more critical to design strategies to mitigate these degradation pathways and to develop means to implement and validate the strategies. A growing set of research highlights the mitigation benefits achievable by forming thin protection layers (PLs) intentionally created as artificial interphase regions at the electrode–electrolyte interface. These advances highlight a promising—perhaps even generic—pathway for enabling higher-energy and higher-voltage battery configurations. In this Account, we summarize examples of such PLs that serve as mitigation strategies to avoid degradation in lithium metal anodes, conversion-type electrode materials, and alloy-type electrodes. Examples are chosen from a larger body of electrochemical degradation research carried out in Nanostructures for Electrical Energy Storage (NEES), our DOE Energy Frontier Research Center. Overall, we argue on the basis of experimental and theoretical evidence that PLs effectively stabilize the electrochemical interfaces to prevent parasitic chemical and electrochemical reactions and mitigate the structural, mechanical, and compositional degradation of the electrode materials at the electrode–electrolyte interfaces. The evidenced improvement in performance metrics is accomplished by (1) establishing a homogeneous interface for ion insertion and extraction, (2) providing mechanical constraints to maintain structural integrity and robust electronic and ionic conduction pathways, and (3) introducing spatial confinements on the electrode material matrix to alter the phase transformation (delaying the occurrence of the conversion reaction) upon Li insertion, which results in superior electrode performance, excellent capacity retention, and improved reversibility. Taken together, these examples portray a valuable role for thin protection layers synthesized over electrode surfaces, both for their benefit to cycle stability and for revealing insights into degradation and mitigation mechanisms. Furthermore, they underscore the impact of complex electrochemical behavior at nanoscale materials and nanostructure interfaces in modulating the behavior of energy storage devices at the mesoscale and macroscale.

25 ENERGY STORAGE↗

Water conservation benefits of urban heat mitigation

Many cities globally are seeking strategies to counter the consequences of both a hotter and drier climate. While urban heat mitigation strategies have been shown to have beneficial effects on health, energy consumption, and greenhouse gas emissions, their implications for water conservation have not been widely examined. Here we use a suite of satellite-supported regional climate simulations in California to show that broad implementation of cool roofs, a heat mitigation strategy, not only results in significant cooling, but can also meaningfully decrease outdoor water consumption by reducing evaporative and irrigation water demands. Irrigation water consumption across the major metropolitan areas is reduced by up to 9% and irrigation water savings per capita range from 1.8 to 15.4 gallons per day across 18 counties examined. Total water savings are found to be the highest in Los Angeles county, reaching about 83 million gallons per day. Cool roofs are a valuable solution for addressing the adaptation and mitigation challenges faced by multiple sectors in California.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Physics-Informed Evolutionary Strategy Based Control for Mitigating Delayed Voltage Recovery

Here, in this work we propose a novel data-driven, real-time power system voltage stability control method based on the physics-informed guided meta evolutionary strategy (ES). The main objective is to quickly provide an adaptive control strategy to secure system voltage stability. The problem is challenging due to the high-dimensional feature of the power system model and the fast-changing and uncertain nature of power system operation scenarios. To this end, a model-free and derivative-free guided ES method is applied. The method is further combined with a meta-learning strategy to make the learnt control policy automatically adapted to unseen operation conditions and fault scenarios, which is highly desired for real-time emergency control. Last but not least, physical knowledge is embedded in the above method through a trainable action mask technique to rule out unnecessary load shedding actions for better learning and control performance. Case studies on the IEEE 300-bus system and comparisons with other state-of-the-art benchmark methods verify the superiority of the proposed physics-informed guided meta ES method in realizing fast and adaptive power system voltage stability control.

42 ENGINEERING↗

Optimal contracting structure between cellulosic biorefineries and farmers to reduce the impact of biomass supply variation: game theoretic analysis

There is considerable year–to–year variability in the supply of cellulosic biomass used in the production of cellulosic biofuels, yet strategies to mitigate these variations in biofuel development are not well understood. Biorefineries and farmers venturing into the cellulosic biofuel industry will require biomass supply and contracting strategies that can minimize the impact of these large variations. Some studies have proposed biomass pre–treatment and storage to address biomass supply variations. Other studies have used transportation modeling approaches to manage supply variations and select the optimal location of a cellulosic biorefinery. However, storage, pre–treatment, and similar engineering approaches lead to higher costs and have other limitations such as additional infrastructural requirements. There is a gap in understanding how contracting strategies between biorefineries and the biomass suppliers (farmers) can reduce the risks with biomass supply variations. In this study, the contracting structure between biorefineries and biomass suppliers is studied under different market structures for the US Corn Belt. A theoretical framework is then developed to use contracting strategies for mitigating the impact of biomass supply variations. First, the trade–offs between intricately linked components of biomass cost, such as biomass transport, biomass price (incentive) to suppliers, variation in biomass supply, biorefinery size, and alternative feedstock availability are examined. Next, an optimal contracting structure is developed between biorefineries and biomass suppliers using game theoretic analysis. Here, the results show that both the impact of biomass supply variations and the overall biomass cost can be significantly reduced through the use of the optimal contracting strategy between biorefineries and suppliers.

cellulosic biofuel↗

Maui Energy Storage Study

This report investigates strategies to mitigate anticipated wind energy curtailment on Maui, with a focus on grid-level energy storage technology. The study team developed an hourly production cost model of the Maui Electric Company (MECO) system, with an expected 72 MW of wind generation and 15 MW of distributed photovoltaic (PV) generation in 2015, and used this model to investigate strategies that mitigate wind energy curtailment. It was found that storage projects can reduce both wind curtailment and the annual cost of producing power, and can do so in a cost-effective manner. Most of the savings achieved in these scenarios are not from replacing constant-cost diesel-fired generation with wind generation. Instead, the savings are achieved by the more efficient operation of the conventional units of the system. Using additional storage for spinning reserve enables the system to decrease the amount of spinning reserve provided by single-cycle units. This decreases the amount of generation from these units, which are often operated at their least efficient point (at minimum load). At the same time, the amount of spinning reserve from the efficient combined-cycle units also decreases, allowing these units to operate at higher, more efficient levels.

Ellison, James↗

Strategies for control and mitigation of efflorescence in metakaolin-based geopolymers

Efflorescence can be harmful to material performance as a consequence of microstructural changes due to leaching and carbonation of alkalis. This article identifies mechanisms of efflorescence in metakaolin-based geopolymers, and approaches to reduce free/mobile alkali cations and pore network connectivity, and hence reduce efflorescence. Mechanical, mass transport and microstructural properties are assessed in metakaolin-based geopolymer cements produced using different alkali concentrations in the alkali activator and substitution/addition of blast furnace slag, silica fume, calcium aluminate cement, silicone oil and a dispersive admixture. The most effective strategy to reduce efflorescence results from increasing Si/Al in the geopolymer gel by addition of soluble silicate, silica fume or silicone oil. Addition of calcium aluminate cement or a dispersive admixture also reduce efflorescence, but are less effective. These results confirm that efflorescence may be reduced by controlling the amount of soluble silicates and reducing free alkali cations in geopolymers, providing enhanced performance and durability.

36 MATERIALS SCIENCE↗

Impact assessment of land use planning driving forces on environment

Land use change may exert a negative impact on environmental quality. A state–impact–state (SIS) model describing a state transform under certain impacts has been integrated into land use planning (LUP) environmental impact assessment (LUPEA). This logical model is intuitive and easy to understand, but the exploration of impact is essential to establish the indicator system and to identify the scope of land use environmental impact when it is applied to a specific region. In this study, we investigated environmental driving forces from land use planning (LUPF), along with the conception, components, scope, and impact of LUPF. This method was illustrated by a case study in Zoucheng, China. Through the results, we concluded that (1) the LUPF on environment are impacts originated from the implementation of LUP on a regional environment, which are characterized by four aspects: magnitude, direction, action point, and its owner; (2) various scopes of LUPF on individual environmental elements based on different standards jointly define the final scope of LUPEA; (3) our case study in Zoucheng demonstrates the practicability of this proposed approach; (4) this method can be embedded into LUPEA with direction, magnitudes, and scopes of the LUPF on individual elements obtained, and the identified indicator system can be directly employed into LUPEA and (5) the assessment helps to identify key indicators and to set up a corresponding strategy to mitigate the negative impact of LUP on the environment, which are two important objectives of strategic environmental assessment (SEA) in LUP. - Highlights: • Environmental driving forces from land use planning (LUPF) are investigated and categorized. • Our method can obtains the direction, magnitudes and scopes of environmental driving forces. • The LUPEA scope is determined by the combination of various scopes of LUPF on individual elements. • LUPF assessment can be embedded into LUPEA. • The method can help to identify key indicators and set up a strategy to mitigate negative environmental impact.

54 ENVIRONMENTAL SCIENCES↗

Mitigation of Syngas Cooler Plugging and Fouling

This Final Report summarizes research performed to develop a technology to mitigate the plugging and fouling that occurs in the syngas cooler used in many Integrated Gasification Combined Cycle (IGCC) plants. The syngas cooler is a firetube heat exchanger located downstream of the gasifier. It offers high thermal efficiency, but its’ reliability has generally been lower than other process equipment in the gasification island. The buildup of ash deposits that form on the fireside surfaces in the syngas cooler (i.e., fouling) lead to reduced equipment life and increased maintenance costs. Our approach to address this problem is that fouling of the syngas cooler cannot be eliminated, but it can be better managed. The research program was funded by DOE using two budget periods: Budget Period 1 (BP1) and Budget Period 2 (BP2). The project used a combination of laboratory scale experiments, analysis of syngas cooler deposits, modeling and guidance from industry to develop a better understanding of fouling mechanisms and to develop and evaluate strategies to mitigate syngas cooler fouling and thereby improve syngas cooler performance. The work effort in BP 1 and BP 2 focused on developing a better understanding of the mechanisms that lead to syngas cooler plugging and fouling and investigating promising concepts to mitigate syngas cooler plugging and fouling. The work effort focused on the following: • analysis of syngas cooler deposits and fuels provided by an IGCC plant collaborating with this project; • performing Jet cleaning tests in the University of Utah Laminar Entrained Flow Reactor to determine the bond strength between an ash deposit to a metal plate, as well as implementing planned equipment modifications to the University of Utah Laminar Entrained Flow Reactor and the one ton per day, pressurized Pilot Scale Gasifier; • performing Computational Fluid Dynamic modeling of industrially relevant syngas cooler configurations to develop a better understanding of deposit formation mechanisms; • performing Techno-Economic-Analysis for a representative IGCC plant to investigate the impact on plant economics, in particular the impacts on the Cost of Electricity (COE), due to plant shutdowns caused by syngas cooler plugging and fouling and potential benefits to plant economics of developing strategies to mitigate syngas cooler fouling; and • performing modeling and pilot scale tests to investigate the potential benefits of using a sorbent (fuel additive) to capture the vaporized metals that result in syngas cooler fouling. All project milestones for BP 1 and BP 2 were achieved. DOE was provided a briefing on our accomplishments in BP1 and BP2 and our proposed plans for Budget Period 3 (BP 3). Based on our research the mitigation technology selected to investigate in BP 3 was the use of a sorbent that can be injected into the gasifier with the fuel slurry to capture vaporized metals that lead to the deposit formation in the syngas cooler. The work effort proposed for BP 3 would have focused on addressing concerns raised by gasification industry personnel for the impacts on gasifier performance of sorbent injection, so that at the end of BP 3 the use of sorbent injection would be at “pre-commercial” stage and ready for use in a Field Demonstration that could be funded by industry or DOE. A Budget Continuation Application (BCA) was submitted to obtain funding for BP3 DOE but DOE chose to not fund the proposed BP3 effort.

47 OTHER INSTRUMENTATION↗

Thermostructural evolution of boron carbide characterized using in-situ x-ray diffraction

Boron carbide, with a nominal stoichiometry of B 4 C, is a highly desired ceramic candidate for armor applications due to its high hardness derived from the complex crystal structure. However, stress-induced local amorphization can lead to failure and is a known challenge for this material which must be addressed for applications in ballistic environments. Understanding boron carbide's atomic structural behavior and bonding environment is critical in determining effective strategies to mitigate these issues. Here, in this work, the thermo-structural behavior of B 4 C has been studied in detail using a conical nozzle levitator system coupled with in-situ synchrotron X-ray diffraction. Lattice expansion and the resulting thermal expansion coefficients (CTEs) were determined from 25-2100 °C. Rietveld refinements showed anisotropic atomic displacement for each of the 4 unique sites as a function of temperature. An exceptionally large z-axis displacement for the boron chain center is linked to bond weakness and may be linked to faster expansion of the α 33 relative to α 11 CTEs. Thermally induced lattice changes can inform the use of boron carbide at elevated temperatures as well as help develop strategies for mitigating structural failure for armor applications.

36 MATERIALS SCIENCE↗

Partitioning Behavior of Organic Contaminants in Carbon Storage Environments: A Critical Review

Carbon capture and storage is a promising strategy for mitigating the CO{sub 2} contribution to global climate change. The large scale implementation of the technology mandates better understanding of the risks associated with CO{sub 2} injection into geologic formations and the subsequent interactions with groundwater resources. The injected supercritical CO{sub 2} (sc-CO{sub 2}) is a nonpolar solvent that can potentially mobilize organic compounds that exist at residual saturation in the formation. Here, we review the partitioning behavior of selected organic compounds typically found in depleted oil reservoirs in the residual oil–brine–sc-CO{sub 2} system under carbon storage conditions. The solubility of pure phase organic compounds in sc-CO{sub 2} and partitioning of organic compounds between water and sc-CO{sub 2} follow trends predicted based on thermodynamics. Compounds with high volatility and low aqueous solubility have the highest potential to partition to sc-CO{sub 2}. The partitioning of low volatility compounds to sc-CO{sub 2} can be enhanced by cosolvency due to the presence of higher volatility compounds in the sc-CO{sub 2}. The effect of temperature, pressure, salinity, pH, and dissolution of water molecules into sc-CO{sub 2} on the partitioning behavior of organic compounds in the residual oil–brine–sc-CO{sub 2} system is discussed. Data gaps and research needs for models to predict the partitioning of organic compounds in brines and from complex mixtures of oils are presented. Models need to be able to better incorporate the effect of salinity and cosolvency, which will require more experimental data from key classes of organic compounds.

54 ENVIRONMENTAL SCIENCES↗

The Role of Dimer Formation in the Nucleation of Superlattice Transformations and Its Impact on Disorder

The formation of defect-free two-dimensional nanocrystal (NC) superstructures remains a challenge as persistent defects hinder charge delocalization and related device performance. Understanding defect formation is an important step toward developing strategies to mitigate their formation. However, specific mechanisms of defect formation are difficult to determine, as superlattice phase transformations that occur during fabrication are quite complex and there are a variety of factors influencing the disorder in the final structure. Here, we use Molecular Dynamics (MD) and electron microscopy in concert to investigate the nucleation of the epitaxial attachment of lead chalcogenide (PbX, where X = S, Se) NC assemblies. We use an updated implementation of an existing reactive force field in an MD framework to investigate how initial orientational (mis)alignment of the constituent building blocks impacts the final structure of the epitaxially connected superlattice. This Simple Molecular Reactive Force Field (SMRFF) captures both short-range covalent forces and long-range electrostatic forces and allows us to follow orientational and translational changes of NCs during superlattice transformation. Our simulations reveal how robust the oriented attachment is with regard to the initial configuration of the NCs, measuring its sensitivity to both in-plane and out-of-plane misorientation. We show that oriented attachment nucleates through the initial formation of dimers, which corroborate experimentally observed structures. We present high-resolution structural analysis of dimers at early stages of the superlattice transformation and rationalize their contribution to the formation of defects in the final superlattice. Collectively, the simulations and experiments presented in this paper provide insights into the nucleation of NC oriented attachment, the impact of the initial configuration of NCs on the structural fidelity of the final epitaxially connected superlattice, and the propensity to form commonly observed defects, such as missing bridges and atomic misalignment in the superlattice due to the formation of dimers. Here, we present potential strategies to mitigate the formation of superlattice defects.

36 MATERIALS SCIENCE↗

Experimental investigation of advanced turbine control strategies and load-mitigation measures with a model-scale floating offshore wind turbine system

To advance the control co-design of offshore wind energy systems, the authors perform basin-scale experiments with a fully instrumented and actuated floating offshore wind turbine model. The model consists of a 1:70 scale performance-matched model of the International Energy Agency Wind Technology Collaboration Programme 15-MW reference turbine atop the VolturnUS-S semisubmersible platform. The Reference OpenSource Controller provides real-time blade pitch and generator torque control. Here we aim to develop an open data set for the validation of numerical models in predicting the influence of turbine control and load-mitigation measures. For this purpose, we measure the effects of advanced turbine control features, including peak shaving and floating feedback as well as hull-based control using tuned mass dampers on the system. Overall, the results demonstrate measurable and consistent influences from the control and load-mitigation measures, thus confirming the usefulness as a validation data set. Peak shaving attenuates the response to wind turbulence at near-rated wind speed. Floating feedback reduces the load and platform pitch motion associated with the negative damping induced by blade pitch control. The tuned mass dampers also attenuate the system response near the targeted frequencies under suitable conditions. We also identify detrimental side effects of each load-mitigation measure.

17 WIND ENERGY↗

Addressing the Challenge of Electrochemical Ionomer Oxidation in Future Anion Exchange Membrane Water Electrolyzers

Hydrogen production through anion-exchange membrane water electrolyzers (AEMWEs) offers cost advantages over proton-exchange membrane counterparts, mainly due to the good oxygen evolution reaction (OER) activity of platinum-group-metal-free catalysts in alkaline environments. However, the electrochemical oxidation of ionomers at the OER catalyst interface can decrease the local electrode pH, which limits AEMWE performance. Various strategies at the single-cell-level have been explored to address this issue. Here, this work reviews the current understanding of electrochemical ionomer oxidation and strategies to mitigate it, providing our perspective on each approach. Our analysis highlights the competitive adsorption strategy as particularly promising for mitigating ionomer oxidation. This Perspective also outlines future directions for advancing high-performance alkaline AEMWEs and other energy devices using hydrocarbon ionomers.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗