Search NASA⌕ Search

SEARCH · Search NASA

Results for “Material Point Method”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,009 records · Page 56

Thermographic phosphor digital image correlation

The invention advances the ratio method of phosphor thermography using two machine vision cameras for full-field temperature measurements of a solid surface. As an example, algorithms from digital image correlation (DIC) can be used to determine the stereoscopic imaging system intrinsic and extrinsic parameters, and accurately register material points on the sample to subpixel locations in each image with 0.07 px or better accuracy. A phosphor calibration sample fabricated using aerosol deposition can be used for in situ determination of the temperature-versus-intensity ratio relationship. The full calibration methodology and several improvements on two-color phosphor thermography open the door for full-field temperature measurements in dynamic tests with deforming test specimens. In particular, thermographic phosphors can be combined with stereo digital image correlation in a novel diagnostic, TP+DIC, to measure time-resolved full-field surface strains and temperatures simultaneously, thereby enabling testing in combined thermo-mechanical environments.

Winters, Caroline↗

Equilibrium, metastability, and hysteresis in a model spin-crossover material with nearest-neighbor antiferromagnetic-like and long-range ferromagnetic-like interactions

Phase diagrams and hysteresis loops were obtained by Monte Carlo simulations and a mean- field method for a simplified model of a spin-crossovermaterialwith a two-step transition between the high-spin and low-spin states. This model is a mapping onto a square-lattice S = 1/2 Ising model with antiferromagnetic nearest-neighbor and ferromagnetic Husimi-Temperley ( equivalent-neighbor) long-range interactions. Phase diagrams obtained by the two methods for weak and strong long-range interactions are found to be similar. However, for intermediate-strength long-range interactions, the Monte Carlo simulations show that tricritical points decompose into pairs of critical end points and mean-field critical points surrounded by horn-shaped regions of metastability. Hysteresis loops along paths traversing the horn regions are strongly reminiscent of thermal two-step transition loops with hysteresis, recently observed experimentally in several spin-crossover materials. As a result, we believe analogous phenomena should be observable in experiments and simulations for many systems that exhibit competition between local antiferromagnetic-like interactions and long-range ferromagnetic-like interactions caused by elastic distortions.

36 MATERIALS SCIENCE↗

Element-resolved Kikuchi pattern measurements of non-centrosymmetric materials

Angle-resolved electron Rutherford backscattering (ERBS) measurements using an electrostatic electron energy analyser can provide unique access to element-resolved crystallographic information. We present Kikuchi pattern measurements of the non-centrosymmetric crystal GaP, separately resolving the contributions of electrons backscattered from Ga and P. In comparison to element-integrated measurements like in the method of electron backscatter diffraction (EBSD), the effect of the absence of a proper 4-fold rotation axis in the point group of GaP can be sensed with a much higher visibility via the element-resolved Ga to P intensity ratio. These element-resolved measurements make it possible to experimentally attribute the previously observed point-group dependent effect in element-integrated EBSD measurements to the larger contribution of electrons scattered from Ga compared to P. - Highlights: •Element specific Kikuchi patterns are presented for GaP. •Absence of a proper four-fold rotation axis is demonstrated. •Ga and P intensity variations after 90 degree rotation have opposite phase. •The asymmetry in the total intensity distribution resembles that of Ga.

36 MATERIALS SCIENCE↗

Discontinuous finite element space-angle treatment of the first order linear Boltzmann transport equation with magnetic fields: Application to MRI-guided radiotherapy

Purpose: The advent of magnetic resonance imaging (MRI) guided radiotherapy systems demands the incorporation of the magnetic field into dose calculation algorithms of treatment planning systems. This is due to the fact that the Lorentz force of the magnetic field perturbs the path of the relativistic electrons, hence altering the dose deposited by them. Building on the previous work, the authors have developed a discontinuous finite element space-angle treatment of the linear Boltzmann transport equation to accurately account for the effects of magnetic fields on radiotherapy doses. Methods: The authors present a detailed description of their new formalism and compare its accuracy to GEANT4 Monte Carlo calculations for magnetic fields parallel and perpendicular to the radiation beam at field strengths of 0.5 and 3 T for an inhomogeneous 3D slab geometry phantom comprising water, bone, and air or lung. The accuracy of the authors’ new formalism was determined using a gamma analysis with a 2%/2 mm criterion. Results: Greater than 98.9% of all points analyzed passed the 2%/2 mm gamma criterion for the field strengths and orientations tested. The authors have benchmarked their new formalism against Monte Carlo in a challenging radiation transport problem with a high density material (bone) directly adjacent to a very low density material (dry air at STP) where the effects of the magnetic field dominate collisions. Conclusions: A discontinuous finite element space-angle approach has been proven to be an accurate method for solving the linear Boltzmann transport equation with magnetic fields for cases relevant to MRI guided radiotherapy. The authors have validated the accuracy of this novel technique against GEANT4, even in cases of strong magnetic field strengths and low density air.

61 RADIATION PROTECTION AND DOSIMETRY↗

New Synthetic Route to 4,6‐Diamino‐5,7‐dinitro‐benzo‐furazan, Important Decomposition Product of 1,3,5‐Triamino‐2,4,6‐trinitrobenzene

The important 1,3,5-triamino-2,4,6-trinitrobenzene (TATB) decomposition byproduct, 4,6-diamino-5,7-dinitro-benzo-furazan (F 1 ), was prepared in a four-step reaction sequence starting with commercially available materials through a key intermediate, 4,6-dichloro-5,7-dinitro-benzo-furazan. The introduction of azido to 4,6-dichloro-benzo-furazan, followed by nitration and amination gave F 1 in good yield. This new method showed a greatly improved yield and ease of purification than previous methods (the total yield was 30%–40% in seven steps). F 1 is a stable yellow solid with a melting point of 308.7°C and a thermal decomposing temperature of 310.3°C (differential scanning calorimetry at 10°C/min heating rate). The solid-state structure was solved by single-crystal X-ray analyses at low temperatures (100 K). The compound crystallizes in a P 2 1 c space group with the formula C 6 H 4 N 6 O 5 •H 2 O with 12 molecules of F 1 /H 2 O in the unit cell. This compound has eluded complete characterization for almost 50 years. With this information, more advanced decomposition models can be created to further improve critical safety margins in handling the energetic material, TATB.

decomposition↗

Dependence of the localized surface plasmon resonance of noble metal quasispherical nanoparticles on their crystallinity-related morphologies

The absorption spectra of 5 nm noble metal nanoparticles (Ag, Au, and Cu) with typical morphologies of multiply twinned particles (MTPs) and single crystals are calculated by using the discrete dipole approximation method. Among the considered morphologies, it is found that icosahedral, cuboctahedral and truncated octahedral particles behave like quasispherical particles whereas the optical response of the decahedral particles significantly differs from the others. This result, which originates from the shape anisotropy of the decahedron, points out the capacity to discriminate decahedral MTPs from a population of particles with mixed crystallinities and related quasispherical shapes.

36 MATERIALS SCIENCE↗

Study of the thermal properties of filaments for 3D printing

Various materials are used for 3D printing, most commonly Acrylonitrile butadiene styrene (ABS), Polylactic acid (PLA), Polyethylene (PET) and Polypropylene (PP). These materials differ mainly in their melting point, which significantly influences the properties of the final products. Filaments are melted in the print head during the printing process. The temperature range is from 150 °C to 250 °C depending on the technology used. The optimum temperature for the cooling substrate on which printing is carried out is chosen so as to ensure uniform cooling and deformation. It generally varies between (40 – 100) °C. From the above it is clear that both temperatures can significantly affect the properties of the printed 3D object. It is therefore important to determine the thermal parameters (thermal conductivity, specific heat and thermal diffusivity) of the materials used across the entire range of temperatures. For evaluating the properties of different types of PLA materials, the step transient method was used, which allows determination of all required parameters using a fractal heat transfer model.

36 MATERIALS SCIENCE↗

Submerged Fatigue Testing of Marine Energy Advanced Materials

Marine energy structures are typically made of advanced composite materials and are subjected to extreme ocean environments in service. In extreme ocean environments, seawater currents and waves load structures repeatedly, which cause two environmental conditions: water intrusion and mechanical fatigue. In prior research, the two environmental conditions were applied sequentially, where composite specimens were aged and then mechanically tested. To understand the combined effects of dynamic loading and water intrusion on composite materials, the present study involves the static and fatigue four-point bend testing of composite coupons in a water tank. The water tank was designed and built to fit either a 100 kN or a 250 kN load frame. Flexural strength value, cycles to failure, and failure mode results from submerged fatigue testing will be used to inform marine energy structure designs. The coupon-scale test method will be used to scale up to and inform methods for subsequent subcomponent testing and standards development. The benefits of designing marine energy structures to informed standards are decreased lifetime costs and increased reliability and energy production, ultimately leading to a sustainable and low-carbon energy system.

composite materials↗

Analysis of transverse shear strains in pre-twisted thick beams using variational asymptotic method

The cross-sectional stiffness matrix is derived for a pre-twisted, moderately thick beam made of transversely isotropic materials and having rectangular cross sections. An asymptotically-exact methodology is used to model the anisotropic beam from 3-D elasticity, without any further assumptions. The beam is allowed to have large displacements and rotations, but small strain is assumed. The strain energy is computed making use of the beam constitutive law and kinematical relations derived with the inclusion of geometrical nonlinearities and an initial twist. The energy functional is minimized making use of the Variational Asymptotic Method (VAM), thereby reducing the cross section to a point on the beam reference line with appropriate properties, forming a 1-D constitutive law. VAM is a mathematical technique employed in the current problem to rigorously split the 3-D analysis of beams into two: a 2-D analysis over the beam cross-sectional domain, which provides a compact semi-analytical form of the properties of the cross sections, and a nonlinear 1-D analysis of the beam ref-erence curve. In this method, as applied herein, the cross-sectional analysis is performed asymptotically by taking advantage of a material small parameter and two geometric small parameters. 3-D strain components are derived using kinematics and arranged in orders of the small parameters. Closed-form expressions are derived for the 3-D non-linear warping and stress fields. Warping functions are obtained by the minimization of strain energy subject to certain set of constraints that render the 1-D strain measures well-defined. The zeroth-order 3-D warping field thus yielded is then used to integrate the 3-D strain energy density over the cross section, resulting in the 1-D strain energy density, which in turn helps identify the corresponding cross-sectional stiffness matrix. The model is capable of predicting interlaminar and transverse shear stresses accurately up to first order.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A parametric approach to irregular fatigue prediction

A parametric approach to irregular fatigue protection is presented. The method proposed consists of two parts: empirical determination of certain characteristics of a material by means of a relatively small number of well-defined standard tests, and arithmetical application of the results obtained to arbitrary loading histories. The following groups of parameters are thus taken into account: (1) the variations of the mean stress, (2) the interaction of these variations and the superposed oscillating stresses, (3) the spectrum of the oscillating-stress amplitudes, and (4) the sequence of the oscillating-stress amplitudes. It is pointed out that only experimental verification can throw sufficient light upon possibilities and limitations of this (or any other) prediction method.

Erismann, T. H.↗

Novel Composites for Wing and Fuselage Applications: Novel Wing Design Concepts - Task 1

Design trade studies were conducted to arrive at advanced wing designs that integrated new material forms with innovative structural concepts and cost-effective fabrication methods. A representative spar was selected for design, fabrication, and test to validate the predicted performance. Textile processes, such as knitting, weaving and stitching, were used to produce fiber preforms that were later fabricated into composite span through epoxy Resin Transfer Molding (RTM), Resin Film Infusion (RFI), and consolidation of commingled thermoplastic and graphite tows. The target design ultimate strain level for these innovative structural design concepts was 6000 mu in. per in. The spars were subjected to four-point beam bending to validate their structural performance. The various material form /processing combination Y-spars were rated for their structural efficiency and acquisition cost. The acquisition cost elements were material, tooling, and labor.

Suarez, J. A.↗

MR-guided Neurolytic Celiac Plexus Ablation: An Evaluation of Effect and Injection Spread Pattern in Cancer Patients with Celiac Tumor Infiltration

ObjectiveThe purpose of this study was to evaluate the feasibility, the initial accuracy, and the effects of the MR-guided neurolytic celiac plexus ablation as a method to treat cancer-induced chronic abdominal pain. Thirteen celiac plexus ablations were performed for 12 patients. A 0.23-T open MRI scanner with optical navigation was used for procedural guidance. As an adjunct to the MR-guided needle positioning, the needle location was confirmed with saline injection and consequent MR imaging (STIR sequence). The spread of the ablative injection material (alcohol-lidocaine mix) was observed by repeating this sequence after the therapeutic injection. Pain scores from seven patients (eight ablations) were used to assess the therapy effect. MR guidance allowed adequate needle positioning and visualization of injection material in all cases. The rest pain scores significantly decreased from 4 (median) at baseline to 1 (median) at 2 weeks (p < 0.05). Average and worst pain experienced during the past week were significantly lower at the 2-week time point compared with the baseline (p < 0.05). However, the intervention did not result in reduction of opioid use at 2 weeks.MR guidance is an accurate and safe method for celiac plexus ablation with positive therapeutic effect.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Integrated analysis of X-ray diffraction patterns and pair distribution functions for machine-learned phase identification

Abstract To bolster the accuracy of existing methods for automated phase identification from X-ray diffraction (XRD) patterns, we introduce a machine learning approach that uses a dual representation whereby XRD patterns are augmented with simulated pair distribution functions (PDFs). A convolutional neural network is trained directly on XRD patterns calculated using physics-informed data augmentation, which accounts for experimental artifacts such as lattice strain and crystallographic texture. A second network is trained on PDFs generated via Fourier transform of the augmented XRD patterns. At inference, these networks classify unknown samples by aggregating their predictions in a confidence-weighted sum. We show that such an integrated approach to phase identification provides enhanced accuracy by leveraging the benefits of each model’s input representation. Whereas networks trained on XRD patterns provide a reciprocal space representation and can effectively distinguish large diffraction peaks in multi-phase samples, networks trained on PDFs provide a real space representation and perform better when peaks with low intensity become important. These findings underscore the importance of using diverse input representations for machine learning models in materials science and point to new avenues for automating multi-modal characterization.

36 MATERIALS SCIENCE↗

Atomic-scale combination of germanium-zinc nanofibers for structural and electrochemical evolution

Alloy materials have been emerged to achieve compatible properties in various applications. The structural manipulation, however, requires sensitive and complicated synthetic process. Herein, we report atomic-scale combination of germanium-zinc distorted alloy exhibiting uncertain eutectic point in a phase diagram can imply a great potential to form atomically collaborated array via a simple fabrication method. When interconnected together, it prevents a fatal sublimation of germanium/germanium oxide during gas-solid phase reduction reaction and allows outstanding electronic conductivity as well as high available capacity in lithium-ion batteries, leading to structural and electrochemical evolution of germanium/zinc distorted array. Further, the unique features are clearly confirmed through in situ analysis. Besides, as-prepared battery anodes remarkably highlights outstanding rate capabilities (capacity retention of ~50% at 20 C compared to 0.2 C-rate) and cycle retention (73% at 3.0 C-rate) with a capacity of 546 mAh g -1 even after 1000 cycles. Even when assembled in a full cell, it notably facilitates considerable energy density during 400 cycles with 99.4% of average coulombic efficiency, which is suitable for a large-scale energy storage system.

36 MATERIALS SCIENCE↗

Atomistic study of stability of xenon nanoclusters in uranium oxide

Density-functional theory calculations of the xenon incorporation energies in point defects in urania have been done in order to fit empirical potentials. With this set of parameters, we have considered the incorporation of xenon in small and extended defects such as planar interstitials, grain boundaries, faceted, and spherical voids. The results show that xenon atoms are more likely to aggregate than to be homogeneously distributed in the urania grains. SIGMA5 grain boundary and spherical shape voids are the most favorable defects of xenon atom incorporation. The presence of xenon atoms in nanovoids affects their shape. The energy gain to aggregate xenon atoms into clusters saturates for cluster sizes of about 15-20 Schottky defects. This demonstrates that medium size defects are just as favorable as big size defects for xenon incorporation.

36 MATERIALS SCIENCE↗

Experimental Assessment of a Novel Touchless Interface for Intraprocedural Imaging Review

Purpose: To examine the feasibility of a novel technology platform that enables real-time touchless interaction with radiology images in both a simulated and an actual clinical setting. Materials and Methods: This platform offers three different modes for image interaction. The gesture recognition mode uses a depth camera to detect the user’s hand gestures which are translated to image manipulation commands. The light projection mode uses the same camera to detect finger point-and-tap movements above the icons which are projected on a surface to activate the commands. The capacitive sensing mode is enabled by a handheld, portable device, over which finger movements are detected by capacitive sensors to control the image review. Following initial feedback, light projection and capacitive sensing modes were selected for further testing by comparing with the conventional mode of image interaction in time trials for performing a series of standardized image manipulation tasks. Finally, the usability of the technology platform was examined in actual clinical procedures. Results: The light projection and the capacitive sensing modes were evaluated in the time trials and exhibited 60% and 71% reduction in time, respectively, relative to the control mode (p < 0.001). Clinical feasibility for this platform was demonstrated in three actual interventional radiology cases. Conclusion: Accessing, navigating, and extracting relevant information from patient images intraprocedurally are cumbersome and time-consuming tasks that affect safety, efficiency, and decision-making during image-guided procedures. This study demonstrated that the novel technology addressed this issue by allowing touchless interaction with these images in the sterile field.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparing the Effects of Nb, Pb, Y, and La Replacement on the Structural, Electrical, and Magnetic Characteristics of Bi-Based Superconductors

In this study, the effects of Pb, Nb, La, and Y replacements were investigated on Bi-based superconducting materials. In preparing the samples, we used a method called solid-state reaction method. The patterns of the X-ray diffraction of all samples indicated presence of Bi-2212 and Bi-2223 phases. The results obtained from XRD revealed that with increase of the melting point of substation elements, the Bi-2223 phase decreased while the Bi-2212 phase and impurity phases of samples grew. From the electrical resistivity measurements using the four-probe method, it was found that sample A with Pb and sample B with La replacements had the maximum and minimum critical temperatures of 111.4 and 81.6 K, respectively. Based on hysteresis loop (M–H) measurement using Bean’s model, estimation of critical current density (J{sub c}) showed that sample A with Pb and sample B with La substitution had the maximum and minimum values respectively. These results may be due to the melting point of these elements with values of 888, 1512, 2315, and 2425 {sup ∘}C for PbO, Nb{sub 2}O{sub 5}, La{sub 2}O{sub 3}, and Y{sub 2}O{sub 3}, respectively. These elements were replaced by Bi{sub 2}O{sub 3} with a melting point of 817 {sup ∘} C. Further, the samples were prepared at the temperature of 845 {sup ∘}C. It seems at this temperature, these elements not only dissolve within the main matrix and participate in the formation of the Bi-2212 phase during the sintering process but they also participate in the development of the variety of the impurity phases as confirmed by XRD results.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Value of Diffusion-Weighted Magnetic Resonance Imaging for Prediction and Early Assessment of Response to Neoadjuvant Radiochemotherapy in Rectal Cancer: Preliminary Results

Purpose: To evaluate diffusion-weighted magnetic resonance imaging (DWI) for response prediction before and response assessment during and early after preoperative radiochemotherapy (RCT) for locally advanced rectal cancer (LARC). Methods and Materials: Twenty patients receiving RCT for LARC underwent MRI including DWI before RCT, after 10-15 fractions and 1 to 2 weeks before surgery. Tumor volume and apparent diffusion coefficient (ADC; b-values: 0-1000 s/mm{sup 2}) were determined at all time points. Pretreatment tumor ADC and volume, tumor ADC change ( Increment ADC), and volume change ( Increment V) between pretreatment and follow-up examinations were compared with histopathologic findings after total mesorectal excision (pathologic complete response [pCR] vs. no pCR, ypT0-2 vs. ypT3-4, T-downstaging or not). The discriminatory capability of pretreatment tumor ADC and volume, Increment ADC, and Increment V for the detection of pCR was compared with receiver operating characteristics analysis. Results: Pretreatment ADC was significantly lower in patients with pCR compared with patients without (in mm{sup 2}/s: 0.94 {+-} 0.12 Multiplication-Sign 10{sup -3} vs. 1.19 {+-} 0.22 Multiplication-Sign 10{sup -3}, p = 0.003), yielding a sensitivity of 100% and specificity of 86% for detection of pCR. The volume reduction during and after RCT was significantly higher in patients with pCR compared with patients without (in %: {Delta}V{sub during}: -62 {+-} 16 vs. -33 {+-} 16, respectively, p = 0.015; and {Delta}V{sub post}: -86 {+-} 12 vs. -60 {+-} 21, p = 0.012), yielding a sensitivity of 83% and specificity of 71% for the {Delta}V{sub during} and, respectively, 83% and 86% for the {Delta}V{sub post}. The Increment ADC during ({Delta}ADC{sub during}) and after RCT ({Delta}ADC{sub post}) showed a significantly higher value in patients with pCR compared with patients without (in %: {Delta}ADC{sub during}: 72 {+-} 14 vs. 16 {+-} 12, p = 0.0006; and {Delta}ADC{sub post}: 88 {+-} 35 vs. 26 {+-} 19, p = 0.0011), yielding a sensitivity and specificity of 100% for the {Delta}ADC{sub during} and, respectively, 100% and 93% for the {Delta}ADC{sub post}. Conclusions: These initial findings indicate that DWI, using pretreatment ADC, {Delta}ADC{sub during}, and {Delta}ADC{sub post} may be useful for prediction and early assessment of pathologic response to preoperative RCT of LARC, with higher accuracy than volumetric measurements.

62 RADIOLOGY AND NUCLEAR MEDICINE↗