Slope Error Measurement Tool for Solar Parabolic Trough Collectors: Preprint

The National Renewable Energy Laboratory (NREL) has developed an optical measurement tool for parabolic solar collectors that measures the combined errors due to absorber misalignment and reflector slope error. The combined absorber alignment and reflector slope errors are measured using a digital camera to photograph the reflected image of the absorber in the collector. Previous work using theimage of the reflection of the absorber finds the reflector slope errors from the reflection of the absorber and an independent measurement of the absorber location. The accuracy of the reflector slope error measurement is thus dependent on the accuracy of the absorber location measurement. By measuring the combined reflector-absorber errors, the uncertainty in the absorber location measurementis eliminated. The related performance merit, the intercept factor, depends on the combined effects of the absorber alignment and reflector slope errors. Measuring the combined effect provides a simpler measurement and a more accurate input to the intercept factor estimate. The minimal equipment and setup required for this measurement technique make it ideal for field measurements.

14 SOLAR ENERGY↗

Solids Accumulation Scouting Studies

The objective of Solids Accumulation activities was to perform scaled testing to understand the behavior of remaining solids in a Double Shell Tank (DST), specifically AW-105, at Hanford during multiple fill, mix, and transfer operations. It is important to know if fissionable materials can concentrate when waste is transferred from staging tanks prior to feeding waste treatment plants. Specifically, there is a concern that large, dense particles containing plutonium could accumulate in poorly mixed regions of a blend tank heel for tanks that employ mixing jet pumps. At the request of the DOE Hanford Tank Operations Contractor, Washington River Protection Solutions, the Engineering Development Laboratory of the Savannah River National Laboratory performed a scouting study in a 1/22-scale model of a waste staging tank to investigate this concern and to develop measurement techniques that could be applied in a more extensive study at a larger scale. Simulated waste tank solids: Gibbsite, Zirconia, Sand, and Stainless Steel, with stainless steel particles representing the heavier particles, e.g., plutonium, and supernatant were charged to the test tank and rotating liquid jets were used to mix most of the solids while the simulant was pumped out. Subsequently, the volume and shape of the mounds of residual solids and the spatial concentration profiles for the surrogate for heavier particles were measured. Several techniques were developed and equipment designed to accomplish the measurements needed and they included: 1. Magnetic particle separator to remove simulant stainless steel solids. A device was designed and built to capture these solids, which represent the heavier solids during a waste transfer from a staging tank. 2. Photographic equipment to determine the volume of the solids mounds. The mounds were photographed as they were exposed at different tank waste levels to develop a composite of topographical areas. 3. Laser rangefinders to determine the volume of the solids mounds. The mounds were scanned after tank supernatant was removed. 4. Core sampler to determine the stainless steel solids distribution within the solids mounds. This sampler was designed and built to remove small sections of the mounds to evaluate concentrations of the stainless steel solids at different special locations. 5. Computer driven positioner that placed the laser rangefinders and the core sampler in appropriate locations over solids mounds that accumulated on the bottom of a scaled staging tank where mixing is poor. These devices and techniques were effective to estimate the movement, location, and concentrations of the solids representing heavier particles and could perform well at a larger scale The experiment contained two campaigns with each comprised of ten cycles to fill and empty the scaled staging tank. The tank was filled without mixing, but emptied, while mixing, in seven batches; the first six were of equal volumes of 13.1 gallons each to represent the planned fullscale batches of 145,000 gallons, and the last, partial, batch of 6.9 gallons represented a full-scale partial batch of 76,000 gallons that will leave a 72-inch heel in the staging tank for the next cycle. The sole difference between the two campaigns was the energy to mix the scaled staging tank, i.e., the nozzle velocity and jet rotational speed of the two jet pumps. Campaign 1 used 22.9 ft/s, at 1.54 rpm based on past testing and Campaign 2 used 23.9 ft/s at 1.75 rpm, based on visual observation of minimum velocity that allowed fast settling solids, i.e., sand and stainless steel, to accumulate on the scaled tank bottom.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Fast-response, high-precision carbon monoxide sensor using a tunable diode laser absorption technique

A tunable diode laser instrument, denoted as DACOM (Differential Absorption CO Measurement), has been developed to meet the fast-response, high-precision CO measurement needs of the GTE (Global Tropospheric Experiment) program. Under the GTE program, DACOM participated in the three field missions of CITE 1 (Chemical Instrumentation Test and Evaluation 1), a project involving the intercomparison of trace gas measurement techniques. DACOM performance, including analyses of measurement error sources, is discussed for the ground-based mission at Wallops Island, VA (summer 1983), and two missions on the NASA CV-990 (fall 1983 and spring 1984). Examples of fast-response (about 1 s), high-precision (+ or - 1 part per billion by volume, + or - 1.5 percent of reading) airborne data are included to illustrate the capability of this instrument.

Sachse, Glen W.↗

Application of Pressure-Sensitive Paint to Rotorcraft

In this presentation, a plan to develop methods for applying pressure-sensitive paint to rotorcraft will be described. These methods are needed because flows over rotor blades are typically very complex and poorly understood and because conventional methods for measuring unsteady pressures on rotor blades (using unsteady pressure transducers provide grossly inadequate spatial resolution. Since PSP is a surface, rather than a point, measurement technique, it has the potential to significantly increase the spatial resolution )f pressure measurements on rotor blades. PSP techniques currently in use at Ames were developed for measuring steady pressures on rigid, complex airplane configurations in large, production wind tunnels. Applying PSP to rotorcraft requires a significant departure from these techniques. First and most importantly new, fast-responding and self-referencing pressure paints are required. The paints must be fast (98% response in 1-5 msec) to resolve flow unsteadiness; they must be self-referencing (or "binary") to account for changes in incident light intensity due to deflection of flexible rotors. Self-referencing paints have been used at Ames for some time; however, these paints have response times that are far too long for unsteady applications. Flash illumination is required to resolve flow unsteadiness and to minimize image blurring due to relative motion between the model and the camera. Current practice at Ames is to use continuous illumination Finally, "in situ" paint calibration versus measurements by pressure transducers, which is current Ames practice, is not practical because of the difficulty and expense of installing transducers in rotor blades. Instead, the paint must be calibrated "a priori" in a calibration chamber. A sequence of five experiments that systematically isolates and addresses the problems involved in making PSP measurements on rotor blades has been planned. These are: (1) measurements on a rigid rotor in hover; (2) measurements on a flexible rotor in hover; measurements of paint response time in a calibration apparatus; (4) measurements on a rigid, two-dimensional oscillating airfoil; and (5) measurements on a flexible rotor in forward flight. Experiments were recently conducted at Ames where PSP measurements were made on a rigid oscillating airfoil (experiment type 4) and on a flexible rotor in hover (experiment type 2). Preliminary results from these experiments will be discussed.

Schairer, Edward T.↗

Comparison of CARS combustion temperatures with standard techniques

This paper describes a comparative study of temperatures measured with Coherent Anti-Stokes Raman Spectroscopy (CARS) and those using standard measurement techniques. CARS temperatures from nitrogen vibrational-rotational spectra have been obtained in a premixed hydrogen-air laboratory flame supported on a flat flame burner over a temperature range from about 1000 K to 2100 K. The techniques used for comparison were sodium line reversal, thin wire thermocouples and heat balance calculations. These studies show a good agreement over the entire temperature range studied.

Antcliff, R. R.↗

Measuring Interfacial Tension Between Immiscible Liquids

Glass capillary tube technique measures interfacial tension between two immiscible liquids. Yields useful data over fairly wide range of interfacial tensions, both for pairs of liquids having equal densities and pairs of liquids having unequal densities. Data on interfacial tensions important in diverse industrial chemical applications, including enhanced extraction of oil; printing; processing foods; and manufacture of paper, emulsions, foams, aerosols, detergents, gel encapsulants, coating materials, fertilizers, pesticides, and cosmetics.

Rashidnia, Nasser↗

At-wavelength Optical Metrology Development at the ALS

Nano-focusing and brightness preservation for ever brighter synchrotron radiation and free electron laser beamlines require surface slope tolerances of x-ray optics on the order of 100 nrad. While the accuracy of fabrication and ex situ metrology of x-ray mirrors has improved over time, beamline in situ performance of the optics is often limited by application specific factors such as x-ray beam heat loading, temperature drift, alignment, vibration, etc. In the present work, we discuss the recent results from the Advanced Light Source developing high accuracy, in situ, at-wavelength wavefront measurement techniques to surpass 100-nrad accuracy surface slope measurements with reflecting x-ray optics. The techniques will ultimately allow closed-loop feedback systems to be implemented for x-ray nano-focusing. In addition, we present a dedicated metrology beamline endstation, applicable to a wide range of in situ metrology and test experiments. The design and performance of a bendable Kirkpatrick-Baez (KB) mirror with active temperature stabilization will also be presented. The mirror is currently used to study, refine, and optimize in situ mirror alignment, bending and metrology methods essential for nano-focusing application.

42 ENGINEERING↗

Three-dimensional shape measurement with a fast and accurate approach

A noncontact, fast, accurate, low-cost, broad-range, full-field, easy-to-implement three-dimensional (3D) shape measurement technique is presented. The technique is based on a generalized fringe projection profilometry setup that allows each system component to be arbitrarily positioned. It employs random phase-shifting, multifrequency projection fringes, ultrafast direct phase unwrapping, and inverse self-calibration schemes to perform 3D shape determination with enhanced accuracy in a fast manner. The relative measurement accuracy can reach 1/10,000 or higher, and the acquisition speed is faster than two 3D views per second. The validity and practicability of the proposed technique have been verified by experiments. Because of its superior capability, the proposed 3D shape measurement technique is suitable for numerous applications in a variety of fields.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

PIV Measurements of Shock-Wave/Boundary-Layer Interactions at Mach 2.5 in a Circular Test Section

The particle image velocimetry (PIV) measurement technique has been applied to make detailed measurements in an impinging shock-wave/boundary-layer interaction (SWBLI) flowfield in a test section of circular cross-section. By virtue of this test section geometry, the flowfields studied are free from effects of the complex coupling of sidewall and corner interaction into the primary impinging shock interaction typical of a rectangular test section. The cone-cylinder shock generator hardware was arranged in both coaxial alignment with the test section to generate axisymmetric SWBLIs and in offset positions to generate swept SWBLIs. The angle of the conical section was also varied to alter the strength of the impinging shock wave. The application of the PIV technique in this test section required meticulous design to provide adequate optical access without disturbing the SWBLI flow. Details of the stereoscopic PIV apparatus and the velocity measurements obtained for a Mach 2.5 freestream are presented. Key features of the mean velocity and turbulent stress fields are highlighted. This data set should enable validation of computational fluid dynamics results for these flowfields.

Shockwave Boundary Layer Interaction↗

PIV Measurements of Shock-Wave/Boundary-Layer Interactions at Mach 2.5 in a Circular Test Section

The particle image velocimetry (PIV) measurement technique has been applied to make detailed measurements in an impinging shock-wave/boundary-layer interaction (SWBLI) flowfield in a test section of circular cross-section. By virtue of this test section geometry, the flowfields studied are free from effects of the complex coupling of sidewall and corner interaction into the primary impinging shock interaction typical of a rectangular test section. The cone-cylinder shock generator hardware was arranged in both coaxial alignment with the test section to generate axisymmetric SWBLIs and in offset positions to generate swept SWBLIs. The angle of the conical section was also varied to alter the strength of the impinging shock wave. The application of the PIV technique in this test section required meticulous design to provide adequate optical access without disturbing the SWBLI flow. Details of the stereoscopic PIV apparatus and the velocity measurements obtained for a Mach 2.5 freestream are presented. Key features of the mean velocity and turbulent stress fields are highlighted. This data set should enable validation of computational fluid dynamics results for these flowfields.

Shockwave Boundary Layer Interaction↗

Evolution, Current State of the Art, and Interpretation of Aircraft-Based Methane Emission Quantification at the Natural Gas Basin-Level

Accurately quantifying methane (CH4) emissions from the oil and gas (O&G) industry is challenging given the existence of many potential emission sources, differences in industry practices and regulations, and often incomplete or out-of-date activity data. It is thus important to regularly assess emission inventories and support improvements by deriving independent estimates using state-of-the-science approaches. Recent research has provided CH4 emission estimates from the O&G supply chains based on different measurement techniques at multiple spatio-temporal scales. Natural gas basin-scale aircraft-based atmospheric measurements indicate greater CH4 emissions than emission inventories based on up-scaling of component-/facility-level emission measurements from a relatively small sample size. Here we present results from a coordinated field study that compares concurrent CH4 emission measurements using different techniques and scales to better understand the strengths and weaknesses of each approach, with a focus on the aircraft-based estimation method. We describe the importance of (i) decades of measurement technology development, (ii) experience in designing measurement sampling strategies and aligning system boundaries, and (Hi) properly interpreting CH4 emission estimates for successfully reconciling aircraft-based measurements with emission inventories and for identifying CH4 emission mitigation potential. We illustrate that aircraft-based top-down estimates represent a brief snapshot of total basin-level CH4 emissions. Thus, a high spatio-temporally resolved bottom-up emission inventory is needed to identify key CH4 sources (including episodic sources) at the process level. While this paper provides a brief overview of the overall study design and findings, its focus is on the implementation of the aircraft measurements and its interpretation and results. A separate paper describes in more detail the overall organizational structure of the study as well as the study implications from an industry perspective.

03 NATURAL GAS↗

High-resolution heat-transfer-coefficient maps applicable to compound-curve surfaces using liquid crystals in a transient wind tunnel

Tests were performed in a transient heat transfer tunnel in which the model under test was preheated prior to allowing room temperature air to be suddenly drawn over the model. The resulting movement of isothermal contours on the model is revealed using a surface coating of thermochromic liquid crystals that display distinctive colors at particular temperatures. A video record is obtained of a temperature and time data pair for all points on the model during a single test. Experiments on a duct model are reported in which the model was preheated using a hot air stream. A manner in which initial model temperature nonuniformities could be taken into account was investigated. The duct model was also tested with a steady-state measurement technique and results were compared with the transient measurements, but recognizing that differences existed between the upstream thermal boundary conditions. The steady-state and transient measurements were shown to be consistent with predicted values. The main advantage of this transient heat transfer technique using liquid crystals is that since the test model need not be actively heated, high-resolution measurements on surfaces with complex shapes may be obtained.

Jones, T. V.↗

High-resolution heat-transfer-coefficient maps applicable to compound-curve surfaces using liquid crystals in a transient wind tunnel

Tests were performed in a transient heat transfer tunnel in which the model under test was preheated prior to allowing room temperature air to be suddenly drawn over the model. The resulting movement of isothermal contours on the model is revealed using a surface coating of thermochromic liquid crystals that display distinctive colors at particular temperatures. A video record is obtained of a temperature and time data pair for all points on the model during a single test. Experiments on a duct model are reported in which the model was preheated using a hot air stream. A manner in which initial model temperature nonuniformities could be taken into account was investigated. The duct model was also tested with a steady-state measurement technique and results were compared with the transient measurements, but recognizing that differences existed between the upstream thermal boundary conditions. The steady-state and transient measurements were shown to be consistent with predicted values. The main advantage of this transient heat transfer technique using liquid crystals is that since the test model need not be actively heated, high-resolution measurements on surfaces with complex shapes may be obtained.

Jones, Terry V.↗

Measuring the permittivity of gases and aerosols

Two-coupler microwave technique measures complex permittivity utilizing waveguide which encloses gas or aerosol. Using technique, blower continuously circulates substances to keep them homogeneous.

Trett, W. J.↗

Application of the pressure sensitive paint technique to steady and unsteady flow

Pressure sensitive paint is a newly-developed optical measurement technique with which one can get a continuous pressure distribution in much shorter time and lower cost than a conventional pressure tap measurement. However, most of the current pressure sensitive paint applications are restricted to steady pressure measurement at high speeds because of the small signal-to-noise ratio at low speed and a slow response to pressure changes. In the present study, three phases of work have been completed to extend the application of the pressure sensitive paint technique to low-speed testing and to investigate the applicability of the paint technique to unsteady flow. First the measurement system using a commercially available PtOEP/GP-197 pressure sensitive paint was established and applied to impinging jet measurements. An in-situ calibration using only five pressure tap data points was applied and the results showed good repeatability and good agreement with conventional pressure tap measurements on the whole painted area. The overall measurement accuracy in these experiments was found to be within 0.1 psi. The pressure sensitive paint technique was then applied to low-speed wind tunnel tests using a 60 deg delta wing model with leading edge blowing slots. The technical problems encountered in low-speed testing were resolved by using a high grade CCD camera and applying corrections to improve the measurement accuracy. Even at 35 m/s, the paint data not only agreed well with conventional pressure tap measurements but also clearly showed the suction region generated by the leading edge vortices. The vortex breakdown was also detected at alpha=30 deg. It was found that a pressure difference of 0.2 psi was required for a quantitative pressure measurement in this experiment and that temperature control or a parallel temperature measurement is necessary if thermal uniformity does not hold on the model. Finally, the pressure sensitive paint was applied to a periodically changing pressure field with a 12.8s time period. A simple first-order pole model was applied to deal with the phase lag of the paint. The unsteady pressure estimated from the time-changing pressure sensitive paint data agreed well with the pressure transducer data in regions of higher pressure and showed the possibility of extending the technique to unsteady pressure measurements. However, the model still needs further refinement based on the physics of the oxygen diffusion into the paint layer and the oxygen quenching on the paint luminescence.

Shimbo, Y.↗

Projection Moire Interferometry for Rotorcraft Applications: Deformation Measurements of Active Twist Rotor Blades

Projection Moire Interferometry (PMI) has been used during wind tunnel tests to obtain azimuthally dependent blade bending and twist measurements for a 4-bladed Active Twist Rotor (ATR) system in simulated forward flight. The ATR concept offers a means to reduce rotor vibratory loads and noise by using piezoelectric active fiber composite actuators embedded in the blade structure to twist each blade as they rotate throughout the rotor azimuth. The twist imparted on the blades for blade control causes significant changes in blade loading, resulting in complex blade deformation consisting of coupled bending and twist. Measurement of this blade deformation is critical in understanding the overall behavior of the ATR system and the physical mechanisms causing the reduction in rotor loads and noise. PMI is a non-contacting, video-based optical measurement technique capable of obtaining spatially continuous structural deformation measurements over the entire object surface within the PMI system field-of-view. When applied to rotorcraft testing, PMI can be used to measure the azimuth-dependent blade bending and twist along the full span of the rotor blade. This paper presents the PMI technique as applied to rotorcraft testing, and provides results obtained during the ATR tests demonstrating the PMI system performance. PMI measurements acquired at select blade actuation conditions generating minimum and maximum rotor loads are provided to explore the interrelationship between rotor loads, blade bending, and twist.

Fleming, Gary A.↗

Absorption technique for OH measurements and calibration

An absorption technique is described which utilizes a stabilized frequency-doubled tunable dye laser and a long-path White cell with high mirror reflectivities both in the red and UV. In laboratory conditions it has been possible to routinely obtain a detection sensitivity of 3 parts in 1,000,000 over absorption paths less than 1 m in length and a detection sensitivity of approximately 6 parts in 100,000 over an absorption path of the order of 1 km. The latter number corresponds to 3,000,000 OH molecules/cu cm, and therefore the technique should be particularly useful for calibration the fluorescence instrument for OH measurements. However, the presence of atmospheric fluctuations coupled with intensity variation accompanying frequency scanning appears to degrade the detection sensitivity in outdoor ambient conditions, thus making it unlikely that this technique can be employed for direct OH monitoring.

Bakalyar, D. M.↗

On the combination of delayed neutron and delayed gamma techniques for fission rate measurement in nuclear fuel

Novel techniques to measure newly induced fissions in spent fuel after re-irradiation at low power have been developed and tested at the Proteus zero-power research reactor. The two techniques are based on the detection of high energy gamma-rays emitted by short-lived fission products and delayed neutrons. The two techniques relate the measured signals to the total fission rate, the isotopic composition of the fuel, and nuclear data. They can be combined to derive better estimates on each of these parameters. This has potential for improvement in many areas. Spent fuel characterisation and safeguard applications can benefit from these techniques for non-destructive assay of plutonium content. Another application of choice is the reduction of uncertainties on nuclear data. As a first application of the combination of the delayed neutron and gamma measurement techniques, this paper shows how to reduce the uncertainties on the relative abundances of the longest delayed neutron group for thermal fissions in {sup 235}U, {sup 239}Pu and fast fissions in {sup 238}U. The proposed experiments are easily achievable in zero-power research reactors using fresh UO{sub 2} and MOX fuel and do not require fast extraction systems. The relative uncertainties (1{sigma}) on the relative abundances are expected to be reduced from 13% to 4%, 16% to 5%, and 38% to 12% for {sup 235}U, {sup 238}U and {sup 239}Pu, respectively. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗