Search NASA⌕ Search

SEARCH · Search NASA

Results for “Nuclear data analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,009 records · Page 56

On the dosimetric effect and reduction of inverse consistency and transitivity errors in deformable image registration for dose accumulation

Purpose: Deformable image registration (DIR) is necessary for accurate dose accumulation between multiple radiotherapy image sets. DIR algorithms can suffer from inverse and transitivity inconsistencies. When using deformation vector fields (DVFs) that exhibit inverse-inconsistency and are nontransitive, dose accumulation on a given image set via different image pathways will lead to different accumulated doses. The purpose of this study was to investigate the dosimetric effect of and propose a postprocessing solution to reduce inverse consistency and transitivity errors. Methods: Four MVCT images and four phases of a lung 4DCT, each with an associated calculated dose, were selected for analysis. DVFs between all four images in each data set were created using the Fast Symmetric Demons algorithm. Dose was accumulated on the fourth image in each set using DIR via two different image pathways. The two accumulated doses on the fourth image were compared. The inverse consistency and transitivity errors in the DVFs were then reduced. The dose accumulation was repeated using the processed DVFs, the results of which were compared with the accumulated dose from the original DVFs. To evaluate the influence of the postprocessing technique on DVF accuracy, the original and processed DVF accuracy was evaluated on the lung 4DCT data on which anatomical landmarks had been identified by an expert. Results: Dose accumulation to the same image via different image pathways resulted in two different accumulated dose results. After the inverse consistency errors were reduced, the difference between the accumulated doses diminished. The difference was further reduced after reducing the transitivity errors. The postprocessing technique had minimal effect on the accuracy of the DVF for the lung 4DCT images. Conclusions: This study shows that inverse consistency and transitivity errors in DIR have a significant dosimetric effect in dose accumulation; Depending on the image pathway taken to accumulate the dose, different results may be obtained. A postprocessing technique that reduces inverse consistency and transitivity error is presented, which allows for consistent dose accumulation regardless of the image pathway followed.

61 RADIATION PROTECTION AND DOSIMETRY↗

MULTI-ISOPTOPE PROCESS MONITOR: A COMPARISON OF MODEL AND EXPERIMENTAL VALIDATION

The MIP Monitoring concept was demonstrated through a series of simulations as well as experiments. While qualitatively these studies generated similar results, there were significant differences between the simulated and experimentally determined spectra. This chapter investigates these differences between modeled and experimentally determined CZT gamma spectra and subsequent PCA analysis generated from each.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Gastrointestinal Dose-Histogram Effects in the Context of Dose-Volume–Constrained Prostate Radiation Therapy: Analysis of Data From the RADAR Prostate Radiation Therapy Trial

Purpose: To use a high-quality multicenter trial dataset to determine dose-volume effects for gastrointestinal (GI) toxicity following radiation therapy for prostate carcinoma. Influential dose-volume histogram regions were to be determined as functions of dose, anatomical location, toxicity, and clinical endpoint. Methods and Materials: Planning datasets for 754 participants in the TROG 03.04 RADAR trial were available, with Late Effects of Normal Tissues (LENT) Subjective, Objective, Management, and Analytic (SOMA) toxicity assessment to a median of 72 months. A rank sum method was used to define dose-volume cut-points as near-continuous functions of dose to 3 GI anatomical regions, together with a comprehensive assessment of significance. Univariate and multivariate ordinal regression was used to assess the importance of cut-points at each dose. Results: Dose ranges providing significant cut-points tended to be consistent with those showing significant univariate regression odds-ratios (representing the probability of a unitary increase in toxicity grade per percent relative volume). Ranges of significant cut-points for rectal bleeding validated previously published results. Separation of the lower GI anatomy into complete anorectum, rectum, and anal canal showed the impact of mid-low doses to the anal canal on urgency and tenesmus, completeness of evacuation and stool frequency, and mid-high doses to the anorectum on bleeding and stool frequency. Derived multivariate models emphasized the importance of the high-dose region of the anorectum and rectum for rectal bleeding and mid- to low-dose regions for diarrhea and urgency and tenesmus, and low-to-mid doses to the anal canal for stool frequency, diarrhea, evacuation, and bleeding. Conclusions: Results confirm anatomical dependence of specific GI toxicities. They provide an atlas summarizing dose-histogram effects and derived constraints as functions of anatomical region, dose, toxicity, and endpoint for informing future radiation therapy planning.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A study of beam position diagnostics using beam-excited dipole modes in third harmonic superconducting accelerating cavities at a free-electron laser

We investigate the feasibility of beam position diagnostics using higher order mode (HOM) signals excited by an electron beam in the third harmonic 3.9 GHz superconducting accelerating cavities at FLASH. After careful theoretical and experimental assessment of the HOM spectrum, three modal choices have been narrowed down to fulfill different diagnostics requirements. These are localized dipole beam-pipe modes, trapped cavity modes from the fifth dipole band, and propagating modes from the first two dipole bands. These modes are treated with various data analysis techniques: modal identification, direct linear regression (DLR), and singular value decomposition (SVD). Promising options for beam diagnostics are found from all three modal choices. This constitutes the first prediction, subsequently confirmed by experiments, of trapped HOMs in third harmonic cavities, and also the first direct comparison of DLR and SVD in the analysis of HOM-based beam diagnostics.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

International Interlaboratory Compilation of Trace Element Concentrations in the CUP-2 Uranium Ore Concentrate Standard

The accurate and precise analysis of impurities in uranium ore concentrates is an important aspect of nuclear forensics. Defensibility of analytical data requires the use of analytical reference materials as part of quality control. This report presents a compilation of the results of trace element concentration measurements of the CUP-2 Uranium Ore Concentration Standard from 11 different laboratories. Various dissolution methods, instrumental platforms, and analytical methods were employed. The resulting data set contains concentration of 66 impurities with up to 139 individual data points for each impurity. Consensus values have been assigned to each impurity following a statistical analysis of the data set.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Primordial non-Gaussianity estimator: The inhomogeneous noise effect

Since the inhomogeneous instrument noise can produce extra non-Gaussianity in the cosmic microwave background (CMB) anisotropy, its effect should be carefully subtracted in the primordial non-Gaussianity estimation. We calculate the probability distribution function of the CMB anisotropy for a local type of non-Gaussianity, from which the optimal estimator in the general case (inhomogeneous noise and cut sky) is obtained. The new estimator obtained here is different from the popular one, since the inhomogeneous noise and cut sky effects are completely accounted for. The CMB anisotropy in the new estimator is noise weighted. The noise weight is different from that used by the WMAP Collaboration in their 5-year data analysis. Although it is still difficult to calculate the new estimator rigorously, for the case of the slightly inhomogeneous noise, there exists a series expansion method to compute the new estimator. Each order in the series is suppressed by two factors, (({sigma}{sup 2}/{sigma}{sub i}{sup 2})-1) and (C{sub l}/C{sub l}{sup tot}), which make the method feasible. Through the Edgeworth expansion we can generalize our discussion to other types of non-Gaussianity.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

AGC-2 Graphite Preirradiation Data Analysis Report (Revision 1)

This report described the specimen loading order and documents all pre-irradiation examination material property measurement data for the graphite specimens contained within the second Advanced Graphite Capsule (AGC-2) irradiation capsule. The AGC-2 capsule is the second in six planned irradiation capsules comprising the Advanced Graphite Creep (AGC) test series. The AGC test series is used to irradiate graphite specimens allowing quantitative data necessary for predicting the irradiation behavior and operating performance of new nuclear graphite grades to be generated which will ascertain the in-service behavior of the graphite for pebble bed and prismatic Very High Temperature Reactor (VHTR) designs. Similar to the AGC-1 specimen pre-irradiation examination report, material property tests were conducted on specimens from 18 nuclear graphite types but on an increased number of specimens (512) prior to loading into the AGC-2 irradiation assembly. All AGC-2 specimen testing was conducted at Idaho National Laboratory (INL) from October 2009 to August 2010. This report also details the specimen loading methodology for the graphite specimens inside the AGC-2 irradiation capsule. The AGC-2 capsule design requires “matched pair” creep specimens that have similar dose levels above and below the neutron flux profile mid-plane to provide similar specimens with and without an applied load. This document utilized the neutron flux profile calculated for the AGC-2 capsule design, the capsule dimensions, and the size (length) of the selected graphite and silicon carbide samples to create a stacking order that can produce “matched pairs” of graphite samples above and below the AGC-2 capsule elevation mid-point to provide specimens with similar neutron dose levels.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Annual report of the international nuclear research initiative OSMOSE project (FY05).

The goal of the OSMOSE program is to measure the reactivity effect of minor actinides in known neutron spectra of interest to the Generation-IV reactor program and other programs and to create a database of these results for use as an international benchmark for the minor actinides. The results are then compared to calculational models to verify and validate integral absorption cross-sections for the minor actinides. The OSMOSE program includes all aspects of the experimental program -- including the fabrication of fuel pellets and samples, the oscillation of the samples in the MINERVE reactor for the measurement of the reactivity effect, reactor physics modeling of the MINERVE reactor, and the data analysis and interpretation of the experimental results.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

A novel integrated time-resolved array avalanche photodiode detection system for nuclear resonant scattering measurements

Here, the nuclear resonant scattering (NRS) experiment requires photon-counting detectors with high time resolution, short dead time, large dynamic range, low noise, and large detection area. An 8-channel avalanche photodiode (APD) array detector system with high integrity, flexibility, and reliability has been developed to adapt to the demands of NRS experiments. The detector system mainly consists of four key parts: (i) an array-APD sensor, (ii) 8-channel integrated fast preamplifiers, (iii) the time-to-digital converter readout electronics, and (iv) a data acquisition system and EPICS support software. Remarkably, the system exhibits a time resolution of better than 500 ps and has a sufficiently low noise level, allowing for the lowest detection energy threshold of 4 keV. The performance of the new array-APD system as well as its real application in nuclear forward scattering (NFS) and nuclear resonant inelastic x-ray scattering (NRIXS) experiments was tested in two synchrotron facilities. With the new system, the NFS signal very close to the prompt electronic scattering signal can be extracted. Thanks to the customized EPICS-areaDetector-based control software, NRIXS spectra can be readily measured with time and energy information of the NRIXS signal stored in the raw data, which is promising for developing NRIXS data analysis in the time domain. The array-APD detector can be deployed for nuclear resonant scattering experiments at various synchrotron radiation facilities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Statistical Analyses of Post Irradiation Experiments of the BWR Forsmark

Computer codes which are to be used in nuclear safety research need to be validated prior to their application. For depletion codes, this validation can be done using data from post irradiation experiments (PIE). These experiments consist of a radiochemical analysis of small parts of a fuel rod (FR), which has been irradiated in a nuclear power plant as part of a fuel assembly (FA). This analysis allows the deduction of the isotopic composition of nuclides important for the desired application case. In addition the operation history at the sample location needs to be known and reported with the analysis results. In our work, we perform uncertainty and sensitivity analyses of a model based on a sample from the boiling water reactor (BWR) Forsmark-3 in order to deduce the influence of uncertain system parameters on the nuclide composition of the depleted fuel. In a second step we compare the resulting uncertainties of the nuclide densities with the deviation between their calculated and experimental values. The goal is to obtain quantitative uncertainty data which can be accounted for in a validation procedure. We use the Monte Carlo sampling approach, i.e. repeating the model calculation using statistically varied sets of the uncertain input parameters and analyzing the distributions of the result values statistically. BWR depletion calculations are especially demanding due to the increased complexity and heterogeneity compared to pressurized water reactors (PWR): extensively variable enrichments, complex FA geometries, partial length FRs, strong axially varying moderator density and the common use of gadolinium as burnable absorber in some of the FRs. However, the precise and correct calculation of BWR-depletion is extremely important in view of a possible application in burnup credit for BWR FAs. Therein credit is taken for the reduced reactivity of spent fuel due to the depletion of {sup 235}U for transport and intermediate or final storage.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Nuclear level densities in {sup 47}V, {sup 48}V, {sup 49}V, {sup 53}Mn, and {sup 54}Mn from neutron evaporation spectra

The spectra of neutrons from the (p, n) reactions on {sup 47}Ti, {sup 48}Ti, {sup 49}Ti, {sup 53}Cr, and {sup 54}Cr nuclei were measured in the proton-energy range 7-11 MeV. The measurements were performed with the aid of a fast-neutron spectrometer by the time-of-flight method over the base of the EGP-15 tandem accelerator of the Institute for Physics and Power Engineering (IPPE, Obninsk). Owing to a high resolution and a high stability of the time-of-flight spectrometer used, low-lying discrete levels could be identified reliably along with a continuum section of neutron spectra. An analysis of measured data was performed within the statistical equilibrium and preequilibrium models of nuclear reactions. The relevant calculations were performed by using the exact formalism of Hauser-Feshbach statistical theory supplemented with the generalized model of a superfluid nucleus, the back-shifted Fermi gas model, and the Gilbert-Cameron composite formula for the nuclear level density. The nuclear level densities for {sup 47}V, {sup 48}V, {sup 49}V, {sup 53}Mn, and {sup 54}Mn were determined along with their energy dependences and model parameters. The results are discussed together with available experimental data and recommendations of model systematics.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Nuclear-level densities in the {sup 49}V and {sup 57}Co nuclei on the basis of evaporated-neutron spectra in (p, n) and (d, n) reactions

The spectra of neutrons from the reactions {sup 49}Ti(p, n){sup 49}V and {sup 57}Fe (p, n){sup 57}Co were measured in the range of proton energies between 8 and 11 MeV along with their counterparts from the reactions {sup 48}Ti(d, n){sup 49}V and {sup 56}Fe (d, n){sup 57}Co at the deuteron energies of 2.7 and 3.8 MeV. These measurements were conducted with the aid of a time-of-flight fast-neutron spectrometer on the basis of the EGP-15 pulsed tandem accelerator of the Institute for Physics and Power Engineering (IPPE, Obninsk). An analysis of measured data was performed within the statistical equilibrium and preequilibrium models of nuclear reactions. The respective calculations based on the Hauser–Feshbach formalism of statistical theory were carried out with nuclear-level densities given by the generalized superfluid model of the nucleus, the backshifted Fermi-gas model, and the Gilbert–Cameron composite formula. The nuclear-level densities of {sup 49}V and {sup 57}Co and their energy dependences were determined. The results were discussed together with available experimental data and data recommended by model systematics.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

JRC-IRMM/ORNL Collaboration on Nuclear Data for Nuclear Criticality Safety - 14486

Concerns about using cross sections recommended in the main evaluated data libraries (i.e. ENDF/B, JEFF and JENDL) for nuclear criticality calculations have been a prime motivator for new cross section measurements. The measurements and evaluations discussed in this work are part of a collaboration between the Oak Ridge National Laboratory (ORNL) and the Institute for Reference Material and Measurements of the Joint Research Center (JRC-IRMM) of the European Commission (EC). They are performed in response to the US Nuclear Criticality Safety Program (NCSP) data needs. In particular, the NCSP five-year plan encompasses a listing of elements that have been identified for measurements and evaluations to address issues on criticality safety applications. This listing is based on data deficiency concerns in practical applications that are conveyed by criticality safety practitioners. In general these deficiencies are obtained through the analysis of benchmark calculations. A wealth of evaluations in the main libraries were derived from results of measurements made with poor time-of-flight resolution, and also the description of some data in the neutron energy range above several tens of keV is crude. This impacts both the resolved and unresolved resonance region, and leads to bias effects when resonance structures play an important role. As a consequence only average corrections can be applied in calculations for nuclear criticality calculations where self-shielding, multiple scattering, or Doppler broadening are important. This can lead to erroneous results. Furthermore, many evaluations for nuclides having small neutron-capture cross sections show erroneously high cross sections because the influence of the neutron sensitivity of the old measurement systems was underestimated. Although their neutron capture cross sections are small, these nuclides, if occurring in large amounts, can be important absorbers in criticality calculations, so an accurate determination of these cross sections is required. Over the last seven years the JRC-IRMM/ORNL collaboration has produced many neutron induced cross section data using the Geel Electron Linear Accelerator (GELINA) neutron time-of-flight facility. This facility is ideally suited to measure total, fission and capture cross sections in the energy range from 1 eV to ∼600 keV, which is important for nuclear criticality calculations. In this paper the facility and experimental set-ups at GELINA will be described together with the data reduction and analysis procedures which result in experimental observables including their full covariance information. The importance of combining transmission and partial cross section data will be emphasized. We will give a list of the measured nuclides and discuss the impact of the resulting data and evaluations. (authors)

42 ENGINEERING↗

Sampling and Analysis Plan for USDOE/NNSA Pantex Plant Groundwater Remedial Action Progress

This Sampling and Analysis Plan (SAP) was originally developed as part of the Remedial Design Submittal Package required by the Interagency Agreement (IAG) for the United States Department of Energy/National Nuclear Security Administration (USDOE/NNSA) Pantex Plant. The SAP describes specifications for data collection, methods of sample collection and analysis, and requirements for quality assurance (QA) and quality control (QC) activities implemented during the life cycle of the program to ensure that data are of sufficient quality for their intended purpose (i.e., to support decision making regarding remediation of the groundwater beneath Pantex). The SAP was prepared according to United States Environmental Protection Agency (EPA) guidance on preparation of Quality Assurance Project Plans (QAPPs) QA/R-5 (EPA, 2001) and is designed to be a stand-alone document that describes both field sampling activities as well as QA/QC activities. The SAP is incorporated by reference to the compliance plan provisions of Hazardous Waste Permit No. 50284, issued by the Texas Commission on Environmental Quality, and was submitted as part of the Remedial Design/Remedial Action Work Plan submitted to EPA in accordance with the Interagency Agreement.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Background investigation in EDELWEISS-III

Protection from and rejection of backgrounds is a key issue for the EDELWEISS-III direct dark matter detection experiment which aims at exploring the 10{sup −9} pb cross-section region for spin-independent WIMP-nucleon interaction. The detector is located in the low radioactivity environment of the Modane Underground Laboratory and consists of 36 advanced FID germanium detectors operating at 18 mK in a dilution refrigerator in order to identify eventual rare nuclear recoils induced by elastic scattering of WIMPs from our Galactic halo. I will discuss the background and the methods of rejecting it with the FID detectors. Detector performances and the first analysis of data acquired in a long-term campaign will be presented as well. The FID detector technology is not limited to EDELWEISS-III but can further be employed in the next generation of cryogenic detector experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Erratum to: Measurements of higher-order cumulants of multiplicity and net-electric charge distributions in inelastic proton-proton interactions by NA61/SHINE

This Erratum replaces, due to a discovery of coding mistakes, the following quantities: κ 3 /κ 1 of the h + − h − distribution presented in Fig. 6 and Table 6, κ 4 listed in Table 4, and $\hat{C}$ 4 presented in Fig. 7 and Table 5. All mentioned figures and tables were updated.

High-Energy Particle Collision Data Analysis↗

SCALE Code System 6.2.2

The SCALE Code System is a widely used modeling and simulation suite for nuclear safety analysis and design that is developed, maintained, tested, and managed by the Reactor and Nuclear Systems Division (RNSD) of Oak Ridge National Laboratory (ORNL). SCALE provides a comprehensive, verified and validated, user-friendly tool set for criticality safety, reactor physics, radiation shielding, radioactive source term characterization, and sensitivity and uncertainty analysis. Since 1980, regulators, licensees, and research institutions around the world have used SCALE for safety analysis and design. SCALE provides an integrated framework with dozens of computational modules including 3 deterministic and 3 Monte Carlo radiation transport solvers that are selected based on the desired solution strategy. SCALE includes current nuclear data libraries and problem-dependent processing tools for continuous-energy (CE) and multigroup (MG) neutronics and coupled neutron-gamma calculations, as well as activation, depletion, and decay calculations. SCALE includes unique capabilities for automated variance reduction for shielding calculations, as well as sensitivity and uncertainty analysis. SCALE’s graphical user interfaces assist with accurate system modeling, visualization of nuclear data, and convenient access to desired results. SCALE 6.2 represents one of the most comprehensive revisions in the history of SCALE, providing several new capabilities and significant improvements in many existing features.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

SCALE Code System

The SCALE Code System is a widely-used modeling and simulation suite for nuclear safety analysis and design that is developed, maintained, tested, and managed by the Reactor and Nuclear Systems Division (RNSD) of Oak Ridge National Laboratory (ORNL). SCALE provides a comprehensive, verified and validated, user-friendly tool set for criticality safety, reactor and lattice physics, radiation shielding, spent fuel and radioactive source term characterization, and sensitivity and uncertainty analysis. Since 1980, regulators, licensees, and research institutions around the world have used SCALE for safety analysis and design. SCALE provides an integrated framework with dozens of computational modules including three deterministic and three Monte Carlo radiation transport solvers that are selected based on the desired solution strategy. SCALE includes current nuclear data libraries and problem-dependent processing tools for continuous-energy (CE) and multigroup (MG) neutronics and coupled neutron-gamma calculations, as well as activation, depletion, and decay calculations. SCALE includes unique capabilities for automated variance reduction for shielding calculations, as well as sensitivity and uncertainty analysis. SCALE’s graphical user interfaces assist with accurate system modeling, visualization of nuclear data, and convenient access to desired results.

97 MATHEMATICS AND COMPUTING↗