Search NASA⌕ Search

SEARCH · Search NASA

Results for “Operation optimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,009 records · Page 56

Fluidized bed coupled rotary reactor for nanoparticles coating via atomic layer deposition

A fluidized bed coupled rotary reactor has been designed for coating on nanoparticles (NPs) via atomic layer deposition. It consists of five major parts: reaction chamber, dosing and fluidizing section, pumping section, rotary manipulator components, as well as a double-layer cartridge for the storage of particles. In the deposition procedure, continuous fluidization of particles enlarges and homogenizes the void fraction in the particle bed, while rotation enhances the gas-solid interactions to stabilize fluidization. The particle cartridge presented here enables both the fluidization and rotation acting on the particle bed, demonstrated by the analysis of pressure drop. Moreover, enlarged interstitials and intense gas–solid contact under sufficient fluidizing velocity and proper rotation speed facilitate the precursor delivery throughout the particle bed and consequently provide a fast coating process. The cartridge can ensure precursors flowing through the particle bed exclusively to achieve high utilization without static exposure operation. By optimizing superficial gas velocities and rotation speeds, minimum pulse time for complete coating has been shortened in experiment, and in situ mass spectrometry showed the precursor usage can reach 90%. Inductively coupled plasma-optical emission spectroscopy results suggested a saturated growth of nanoscale Al{sub 2}O{sub 3} films on spherical SiO{sub 2} NPs. Finally, the uniformity and composition of the shells were characterized by high angle annular dark field-transmission electron microscopy and energy dispersive X-ray spectroscopy.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Interband cascade lasers with >40% continuous-wave wallplug efficiency at cryogenic temperatures

Broad-area 10-stage interband cascade lasers (ICLs) emitting at λ = 3.0–3.2 μm are shown to maintain continuous-wave (cw) wallplug efficiencies exceeding 40% at temperatures up to 125 K, despite having a design optimized for operation at ambient and above. The cw threshold current density at 80 K is only 11 A/cm{sup 2} for a 2 mm cavity with anti-reflection/high-reflection coatings on the two facets. The external differential quantum efficiency for a 1-mm-long cavity with the same coatings is 70% per stage at 80 K, and still above 65% at 150 K. The results demonstrate that at cryogenic temperatures, where free carrier absorption losses are minimized, ICLs can convert electrical to optical energy nearly as efficiently as the best specially designed intersubband-based quantum cascade lasers.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Helium refrigeration systems for super-conducting accelerators

Many of the present day accelerators are based on superconducting technology which requires 4.5-K or 2-K helium refrigeration systems. These systems utilize superconducting radio frequency (SRF) cavities and/or superconducting magnets which are packaged into vacuum vessels known as cryo-modules (CM’s). Many of the present day accelerators are optimized to operate primarily at around 2-K, requiring specialized helium refrigeration systems which are cost intensive to produce and to operate. Some of the cryogenic refrigeration system design considerations for these challenging applications are discussed.

43 PARTICLE ACCELERATORS↗

Improvement in the spatial resolution of heavy ion beam probe measurements through application of ion optics

A technique for more accurately modeling and improving the spatial resolution of heavy ion beam probe measurements is described. We use a set of particle trajectories to numerically determine the focusing properties of a complicated three-dimensional magnetic field and characterize those properties with a transfer matrix. We then modify the transfer matrix approach of traditional ion optics to include a parameter that describes the ionization location of the detected ions. The ion optics model calculated using this technique enables a more accurate description of the particle trajectories than previously feasible. The model also allows one to easily determine an initial beam focus that could be used during experimental operation to optimize the spatial resolution of measurements. The technique has been applied to the design of a heavy ion beam probe diagnostic for the Wendelstein 7-X stellarator and improvements in the modeled spatial resolution by a factor of about 2 over previous estimates are possible. As a result, the improved spatial resolution will enable measurements of plasma fluctuations with smaller wavelengths than would otherwise be possible.

43 PARTICLE ACCELERATORS↗

Ion temperature measurements from tomographic reconstruction of Doppler spectra in the presence of multi-component flow in two dimensions

A new ion Doppler diagnostic has been constructed to measure ion temperature profiles in the presence of multi-component flow during magnetic reconnection experiments. The inversion technique and diagnostic setup are applicable to axisymmetric plasmas with two-component flow across the measurement cross section, which occurs during magnetic reconnection. The particular design discussed here is optimized for operation on the Magnetic Reconnection eXperiment (MRX) at Princeton Plasma Physics Laboratory. To prove the viability of this diagnostic for MRX and the future Facility for Laboratory Reconnection Experiments, measurements have been taken and ion temperature and perpendicular flow profiles have been obtained. The radial velocity on MRX does not contribute to the Doppler shift of the measured spectra but does contribute to the broadening of the spectra, while toroidal flow contributes to both. It is shown that neglecting the radial velocity for vR = 20 km/s leads to an error in the ion temperature inversion of 20%. Results from MRX discharges are shown, and the impact of radial velocity on ion temperature inversions is discussed.

Goodman, A. (ORCID:0000000336396572)↗

Direct current magnetic Hall probe technique for measurement of field penetration in thin film superconductors for superconducting radio frequency resonators

Superconducting Radio Frequency (SRF) cavities used in particle accelerators are typically formed from or coated with superconducting materials. Currently, high purity niobium is the material of choice for SRF cavities that have been optimized to operate near their theoretical field limits. This brings about the need for significant R & D efforts to develop next generation superconducting materials that could outperform Nb and keep up with the demands of new accelerator facilities. To achieve high quality factors and accelerating gradients, the cavity material should be able to remain in the superconducting Meissner state under a high RF magnetic field without penetration of quantized magnetic vortices through the cavity wall. Therefore, the magnetic field at which vortices penetrate a superconductor is one of the key parameters of merit of SRF cavities. Techniques to measure the onset of magnetic field penetration on thin film samples need to be developed to mitigate the issues with the conventional magnetometry measurements that are strongly influenced by the film orientation and shape and edge effects. In this work, we report the development of an experimental setup to measure the field of full flux penetration through films and multi-layered superconductors. Our system combines a small superconducting solenoid that can generate a magnetic field of up to 500 mT at the sample surface and three Hall probes to detect the full flux penetration through the superconductor. We report this setup can be used to study alternative materials that could potentially outperform niobium, as well as superconductor–insulator–superconductor (SIS) multilayer coatings on niobium.

47 OTHER INSTRUMENTATION↗

Conductivity space isotherm behavior in quantum anomalous Hall devices

The quantum Hall effect (QHE) has enhanced accessibility to measure and disseminate electrical units, owed in part to the recently redefined International System of Units in 2019. Graphene remains one of the preferred options to realize the ohm despite the limitations of high magnetic fields to produce a robust QHE. Topological insulators, on the other hand, show promise in providing quantized resistance via the quantum anomalous Hall effect, a phenomenon that removes the need for magnetic fields during operation. To optimize future devices for metrological applications, it is important to gain a better understanding of magnetically doped topological insulators like Cr-doped bismuth antimony telluride. The application of differential conductivity space analyses offers a more sensitive way to analyze the data and distinguish between 2D and 3D transport behaviors. This is particularly important in thin films, where the transition between 2D and 3D behavior can be subtle. The ability to confidently determine the dimensionality of the transport is crucial for selecting appropriate theoretical models for future device optimization. Furthermore, this work identifies variable range hopping as the dominant transport mechanism in the 2D regime using a rigorous statistical analysis (via the Bayes factor). These elements assist in the understanding of microscopic processes that govern charge transport in these materials.

Tran, N. T. M. [National Inst. of Standards and Te↗

Impact of reverse flow induced by a sawtooth anode on the performance of an argon Hall thruster

This study reports the performance comparison of the RAIJIN-66 TAL-type Hall thruster with argon propellant, using two hollow anode designs, one with a simple straight shape and another one with a sawtooth shape. Simulations of the rarefied gas in the sawtooth hollow anode region suggest a successful reversal of the direction of neutral particle flow, with an average increase in the neutral particle density by 15.5% when compared to the straight-shaped hollow anode. This contributes to the improvement in performance across a range of discharge voltages that was measured experimentally. When the thruster is operated with a discharge voltage of 150 V and a flow rate of 70 SCCM, the propellant utilization efficiency with the straight anode is 14%, while with the sawtooth anode it is 25.1%. The anode efficiency reaches in the vicinity of 15% with the sawtooth anode in high voltage conditions, exceeding the efficiencies achieved with the straight anode in the same operating conditions. The optimal magnetic field condition for argon operation and the tuning parameters of the sawtooth anode design for RAIJIN-66 are also discussed.

Satpathy, Dibyesh [Univ. of Tokyo (Japan)] (ORCID:↗

Optical characteristics of a HgBr excilamp

Optical characteristics of a coaxial HgBr excilamp on multicomponent mercury dibromide vapour mixtures with helium, nitrogen and sulfur hexafluoride are investigated under pumping by a pulse-periodic barrier discharge. Stable excilamp operation was demonstrated at a pump pulse repetition rate of 3 – 9 kHz. The component composition of the working system was determined, which provides a maximal average and pulsed specific radiation power of 48.8 mW cm{sup -3} and 40.6 W cm{sup -3}, respectively, at the efficiency of 7.3 % in the blue-green spectral range with the maximal radiation intensity at the wavelength of 502 nm. The reduction in the radiation power after 2.5 × 10{sup 6} shots is 5 %. Interpretation is given for the results of optimisation of excilamp characteristics. (optical radiation sources)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Ion Fluxes and Neutral Gas Ionization Efficiency of the 100-kW Light-Ion Helicon Plasma Source Concept for the Material Plasma Exposure eXperiment

Linear plasma devices are cost-effective alternatives for testing materials under reactor-relevant divertor plasma conditions. In this work, we describe how an intense radio-frequency (RF) plasma source concept for the Material Plasma Exposure eXperiment (MPEX) is under development at Oak Ridge National Laboratory. The source concept, Proto-MPEX, aims to produce high-density background deuterium helicon plasmas ( n e > 3 × 10 19 m - 3 ) that are subsequently heated with additional RF and microwave systems to deliver reactor-relevant conditions for studies on plasma-material interaction. In this work, we focus on the plasma-producing stage and its effectiveness in converting input neutral gas into plasma, namely, the neutral gas ionization efficiency. We provide a direct quantitative measurement of the ionization efficiency by measuring the total ion flux arriving at the target region relative to the neutral gas injected at the source. Using 80 kW at 13.56 MHz and a source magnetic field of 0.05 T, the helicon plasma source delivers ion fluxes up to 1 × 10 24 m - 2 s - 1 and heat fluxes greater than 1 M W m - 2 to a target plate located 2 m away from the source. Under these conditions, we observe that the plasma source converts ~89% of the input neutral gas into plasma that arrives at the target as ion flux at a rate of 5 × 10 20 s - 1 . We demonstrate that because of the large pumping capacity of the plasma, neutral gas pumping systems are required only in the target region to maintain optimal plasma operation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

IMPROVED ALGORITHMS FOR RADAR-BASED RECONSTRUCTION OF ASTEROID SHAPES

We describe our implementation of a global-parameter optimizer and Square Root Information Filter into the asteroid-modeling software shape. We compare the performance of our new optimizer with that of the existing sequential optimizer when operating on various forms of simulated data and actual asteroid radar data. In all cases, the new implementation performs substantially better than its predecessor: it converges faster, produces shape models that are more accurate, and solves for spin axis orientations more reliably. We discuss potential future changes to improve shape's fitting speed and accuracy.

79 ASTRONOMY AND ASTROPHYSICS↗

High power density soft x-ray GaAs photodiodes with tailored spectral response

GaAs photodiode arrays have been designed for non-destructive monitoring of x-ray beam position in soft coherent beamline front ends in synchrotron light sources. A shallow p-on-n junction was employed to reduce the device photocurrent density to optimize the operation with beam power densities up to 20 W mm -2 , mainly coming from hard x-rays. With this approach, the photocurrent is primarily defined by the excess carriers generated by low-energy x-ray photons absorbed near the detector surface. The p–n junction structures were grown by molecular beam epitaxy and processed into 64-element linear photodiode arrays. The devices were characterized first in the visible range with a high-power Ar-ion laser and then tested in the soft and hard x-ray regions up to 10 keV at two beamlines of the National Synchrotron Light Source II. The responsivity was measured to be 0.16 A W -1 at 0.7 keV and 0.05 A W -1 at 6 keV in agreement with modeling. At higher x-ray energies the measured responsivity was lower than predicted in the framework of the carrier diffusion model; a possible explanation is discussed.

36 MATERIALS SCIENCE↗

MCP-PMT studies at the High-B test facility at Jefferson Lab

Here we present preliminary results for the gain performance of commercially available 3- mum and 6- mum pore-size single-anode microchannel-plate photomultipliers (MCP PMTs) in magnetic fields up to 5 T and for various orientations of the sensor relative to the field direction. The measurements were performed at Thomas Jefferson National Accelerator Facility in Newport News, VA. Our results show that smaller-pore-size PMTs have better gain performance in magnetic fields. At various angles, the shape of the gain dependence on the strength of the magnetic field strongly depends on the type of the sensor. Also, for each sensor, the azimuthal dependence is strongly correlated with the polar angle. Overall, the sensors exhibit a reasonable performance up to 2 T, although that upper limit depends on the sensor, the applied high voltage, and the orientation of the sensor relative to the field. To optimize the operational and design parameters of MCP PMTs for performance in high magnetic fields, further measurements and simulation studies will be pursued. Furthermore, our studies are part of an R&D for development of a Detector of Internally Reflected Cherenkov Light for the central detector of a future U.S. Electron Ion Collider.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Achievable noise performance of spectroscopic prototype DEPFET detectors

A new generation of spectroscopic X-ray DEPFET detectors has been produced here in the course of the detector development for the Wide Field Imager (WFI) of Athena. These devices served to perform a detailed analysis of the noise composition, which was enabled by the development of appropriate test algorithms. A result of the analysis is the distinction of different components, which sum up to the total noise. In particular the contribution of shot noise, white noise and 1/f noise to the readout noise is determined as well as the signal noise caused by the generation of charge carriers. The resulting parametrization enables the adaptation and optimization of operation modes to given purposes. The studied prototype detectors included 64×64 pixels with a linear gate design and provided an excellent noise, below 1.6 e - ENC at a readout time faster than 10 μs/pixel and a temperature of -80 °C in rolling-shutter operation. This performance is enabled by an extended signal integration time. A further noise reduction is prevented by the signal noise, caused by charge carrier generation. In order to demonstrate the low noise properties of the DEPFET transistor, the measurement conditions were adapted and a noise of 0.95 e - ENC was measured at the expense of the sensor size—by operating only parts of the sensor in window mode—and dynamic range—by using the Al Kα line at about 1.49 keV for calibration.

47 OTHER INSTRUMENTATION↗

Speeding up particle track reconstruction using a parallel Kalman filter algorithm

One of the most computationally difficult problems expected for the High-Luminosity Large Hadron Collider (HL-LHC) is determining the trajectory of charged particles during event reconstruction. Algorithms used at the LHC today rely on Kalman filtering, which builds physical trajectories incrementally while incorporating material effects and error estimation. Recognizing the need for faster computational throughput, we have adapted Kalman-filter-based methods for highly parallel, many-core SIMD architectures that are now prevalent in high-performance hardware. In this paper, we discuss the design and performance of the improved tracking algorithm, referred to as mkFit. A key piece of the algorithm is the Matriplex library, containing dedicated code to optimally vectorize operations on small matrices. The physics performance of the mkFit algorithm is comparable to the nominal CMS tracking algorithm when reconstructing tracks from simulated proton-proton collisions within the CMS detector. We study the scaling of the algorithm as a function of the parallel resources utilized and find large speedups both from vectorization and multi-threading. mkFit achieves a speedup of a factor of 6 compared to the nominal algorithm when run in a single-threaded application within the CMS software framework.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Glueballs at finite temperature in SU(3) Yang-Mills theory

Thermal properties of glueballs in SU(3) Yang-Mills theory are investigated in a large temperature range from 0.3T{sub c} to 1.9T{sub c} on anisotropic lattices. The glueball operators are optimized for the projection of the ground states by the variational method with a smearing scheme. Their thermal correlators are calculated in all 20 symmetry channels. It is found in all channels that the pole masses M{sub G} of glueballs remain almost constant when the temperature is approaching the critical temperature T{sub c} from below, and start to reduce gradually with the temperature going above T{sub c}. The correlators in the 0{sup ++}, 0{sup -+}, and 2{sup ++} channels are also analyzed based on the Breit-Wigner Ansatz by assuming a thermal width {gamma} to the pole mass {omega}{sub 0} of each thermal glueball ground state. While the values of {omega}{sub 0} are insensitive to T in the whole temperature range, the thermal widths {gamma} exhibit distinct behaviors at temperatures below and above T{sub c}. The widths are very small (approximately a few percent of {omega}{sub 0} or even smaller) when T<T{sub c}, but grow abruptly when T>T{sub c} and reach values of roughly {gamma}{approx}{omega}{sub 0}/2 at T{approx_equal}1.9T{sub c}.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Dispersive X-ray absorption spectroscopy using independent grazing-incidence focusing and convexly bent Bragg-crystal dispersing optics

We present a modular instrument for dispersive X-ray absorption spectroscopy (DXAS) developed for the Advanced Spectroscopy Beamline at Sector 25 of the Advanced Photon Source. The setup employs a double-multilayer monochromator to provide X-rays with a broad energy bandwidth, Kirkpatrick–Baez mirrors for focusing, a convexly bent Bragg-crystal polychromator for energy dispersion, and a pixel-array detector to resolve all X-ray energies and collect their intensity simultaneously, thereby enabling acquisition of a full X-ray absorption spectrum in a single shot. The use of separate optics for X-ray focusing and energy dispersion provides high spatial resolution and avoids chromatic aberrations inherent in focusing bent-crystal optics, and a modular design makes implementation of the technique at other beamlines possible without requiring modifications to the upstream beamline configurations. Theoretical calculations are performed to determine optimal instrument operating parameters and demonstrate that an energy resolution better than the K-edge core-hole lifetime broadening can be maintained while providing a sufficient bandwidth for X-ray absorption near-edge structure spectroscopy through the full operating range of 5–11 keV. Additionally, instrument design, data analysis methods, and initial DXAS results on lithium–manganese–nickel oxide laminates are presented.

47 OTHER INSTRUMENTATION↗

Commissioning and performance of the ATLAS transition radiation tracker with first high energy pp and Pb-Pb collisions at LHC

The ATLAS Transition Radiation Tracker (TRT) is the outermost of the three sub-systems of the ATLAS Inner Detector at the Large Hadron Collider at CERN. It consists of close to 300000 thin-wall drift tubes (straws) providing on average 30 two-dimensional space points with 0.12-0.15 mm resolution for charged particle tracks with |{eta}| < 2 and pt > 0.5 GeV. Along with continuous tracking, it provides particle identification capability through the detection of transition radiation X-ray photons generated by high velocity particles in the many polymer fibers or films that fill the spaces between the straws. Custom-built analog and digital electronics is optimized to operate as luminosity increases to the LHC design. In this article, a review of the commissioning and first operational experience of the TRT detector will be presented. Emphasis will be given to performance studies based on the reconstruction and analysis of LHC collisions. The first studies of the TRT detector response to the extremely high track density conditions during the November 2010 heavy ion LHC running period will be presented. These studies give interesting insight to the expected performance of the TRT in future high luminosity LHC proton-proton runs. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗