Search NASA⌕ Search

SEARCH · Search NASA

Results for “Optical systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,009 records · Page 56

Laser Doppler anemometer diagnostics in unsteady flows

The application of the laser Doppler anemometer (LDA) to unsteady flows is discussed with respect to necessary features of the signal processor, properties of the optical system, and the character of the flow under investigation. The discussion of signal processors includes consideration of frequency trackers, counter-type processors, particle properties, data rates, and statistics. Secondly, diffraction limitations for an optical system are viewed with respect to spatial resolution. Finally, the total velocity field is decomposed into its subfields and the feasibility of, criteria for, and possible types of conditional sampling are defined. Several reported LDA experiments using conditional sampling are presented to demonstrate the different techniques that may be used.

Orloff, K. L.↗

Comments on ''Accuracy of Raman lidar water vapor calibration and its applicability to long-term measurements''

In a recent publication, Leblanc and McDermid [Appl. Opt., 47, 5592 (2008)]APOPAI0003-693510.1364/AO.47.005592 proposed a hybrid calibration technique for Raman water vapor lidar involving a tungsten lamp and radiosondes. Measurements made with the lidar telescope viewing the calibration lamp were used to stabilize the lidar calibration determined by comparison with radiosonde. The technique provided a significantly more stable calibration constant than radiosondes used alone. The technique involves the use of a calibration lamp in a fixed position in front of the lidar receiver aperture. We examine this configuration and find that such a configuration likely does not properly sample the full lidar system optical efficiency. While the technique is a useful addition to the use of radiosondes alone for lidar calibration, it is important to understand the scenarios under which it will not provide an accurate quantification of system optical efficiency changes. We offer examples of these scenarios. Scanning of the full telescope aperture with the calibration lamp can circumvent most of these limitations. Based on the work done to date, it seems likely that the use of multiple calibration lamps in different fixed positions in front of the telescope may provide sufficient redundancy for long-term calibration needs. Further full-aperture scanning experiments, performed over an extended period of time, are needed to determine a ''best practice'' for the use of multiple calibration lamps in the hybrid technique.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Adaptive Optics: Arroyo Simulation Tool and Deformable Mirror Actuation Using Golay Cells

The Arroyo C++ libraries, written by Caltech post-doc student Matthew Britton, have the ability to simulate optical systems and atmospheric signal interference. This program was chosen for use in an end-to-end simulation model of a laser communication system because it is freely distributed and has the ability to be controlled by a remote system or "smart agent." Proposed operation of this program by a smart agent has been demonstrated, and the results show it to be a suitable simulation tool. Deformable mirrors, as a part of modern adaptive optics systems, may contain thousands of tiny, independently controlled actuators used to modify the shape of the mirror. Each actuator is connected to two wires, creating a cumbersome and expensive device. Recently, an alternative actuation method that uses gas-filled tubes known as Golay cells has been explored. Golay cells, operated by infrared lasers instead of electricity, would replace the actuator system thereby creating a more compact deformable mirror. The operation of Golay cells and their ability to move a deformable mirror in excess of the required 20 microns has been demonstrated. Experimentation has shown them to be extremely sensitive to pressure and temperature, making them ideal for use in a controlled environment.

Lint, Adam S.↗

Comments on: Accuracy of Raman Lidar Water Vapor Calibration and its Applicability to Long-Term Measurements

In a recent publication, LeBlanc and McDermid proposed a hybrid calibration technique for Raman water vapor lidar involving a tungsten lamp and radiosondes. Measurements made with the lidar telescope viewing the calibration lamp were used to stabilize the lidar calibration determined by comparison with radiosonde. The technique provided a significantly more stable calibration constant than radiosondes used alone. The technique involves the use of a calibration lamp in a fixed position in front of the lidar receiver aperture. We examine this configuration and find that such a configuration likely does not properly sample the full lidar system optical efficiency. While the technique is a useful addition to the use of radiosondes alone for lidar calibration, it is important to understand the scenarios under which it will not provide an accurate quantification of system optical efficiency changes. We offer examples of these scenarios.

Whiteman, David N.↗

Full color hybrid display for aircraft simulators

A full spectrum color monitor, connected to the camera and lens system of a television camera supported by a gantry frame over a terrain model simulating an aircraft landing zone, projects the monitor image onto a lens or screen visually accessible to a trainee in the simulator. A digital computer produces a pattern corresponding to the lights associated with the landing strip onto a monochromatic display, and an optical system projects the calligraphic image onto the same lens so that it is superposed on the video representation of the landing field. The optical system includes a four-color wheel which is rotated between the calligraphic display and the lens, and an apparatus for synchronizing the generation of a calligraphic pattern with the color segments on the color wheel. A servo feedback system responsive to the servo motors on the gantry frame produces an input to the computer so that the calligraphically generated signal corresponds in shape, size and location to the video signal.

Chase, W. D.↗

The use of an optical data acquisition system for bladed disk vibration analysis

A new concept in instrumentation was developed by engineers at NASA Lewis Research Center to collect vibration data from multi-bladed rotors. This new concept, known as the optical data acquisition system, uses optical transducers to measure bladed tip delections by reflection light beams off the tips of the blades as they pass in front of the optical transducer. By using an array of transducers around the perimeter of the rotor, detailed vibration signals can be obtained. In this study, resonant frequencies and mode shapes were determined for a 56 bladed rotor using the optical system. Frequency data from the optical system was also compared to data obtained from strain gauge measurements and finite element analysis and was found to be in good agreement.

Lawrence, C.↗

The use of an optical data acquisition system for bladed disk vibration analysis

A new concept in instrumentation was developed by engineers at NASA Lewis Research Center to collect vibration data from multi-bladed rotors. This new concept, known as the optical data acquisition system, uses optical transducers to measure bladed tip deflections by reflection of light beams off the tips of the blades as they pass in front of the optical transducer. By using an array of transducers around the perimeter of the rotor, detailed vibration signals can be obtained. In this study, resonant frequencies and mode shapes were determined for a 56 bladed rotor using the optical system. Frequency data from the optical system was also compared to data obtained from strain gauge measurements and finite element analysis and was found to be in good agreement.

Lawrence, C.↗

Wavefront Preservation in Soft X-Ray Beamlines for the Advanced Light Source Upgrade

In the 4th generation of X-ray light sources, including Free-Electron Lasers (FEL) and Diffraction-Limited Storage Rings (DLSR), the emittance of the electron beam is small or negligible compared to the emittance of the photon beam produced by insertion devices, thus generating coherent beams of light. Over the next few years, several lightsource facilities will be built or upgraded to produce X-ray beams of unprecedented coherent flux. Delivering these exceptional beams to the sample chambers requires beamline optical systems that are designed to preserve the wavefront properties. Our goal in the Advanced Light Source upgrade project (ALS-U) is to create a new class of beamlines that reach diffraction-limited X-ray optical quality through tightly integrated, efficient optical systems, diagnostics, and adaptive mirrors, thus providing users with new scientific capabilities offered by coherent X-ray light interactions with matter. Herein we describe aspects of the beamlines’ design as they enter the project’s final design phase.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optical measurements and tests performed in a low-gravity environment

Shadowgraph and schlieren techniques have been used on board the NASA KC-135 low-gravity simulation aircraft to measure gravity-related fluid flow occurring in various experimental configurations. These configurations included cooled and solidified ammonium chloride and water, electrodeposited cobalt in CoSO4 solution, and immiscible and crystal melt solutions. Hardware tests have also been performed for such critical optical system components as lasers and spatial filters to determine their performance and operation under low-gravity conditions. These test results will be used in the design of the various future Shuttle experiments which will utilize advanced optical measurement techniques. The design and configuration of the optical systems used to make these measurements and tests are presented, and the performance and operation of these systems and their components under low-gravity conditions are discussed. Some preliminary results are included.

Owen, R. B.↗

Horizon: A Proposal for Large Aperture, Active Optics in Geosynchronous Orbit

In 1999, NASA's New Millennium Program called for proposals to validate new technology in high-earth orbit for the Earth Observing-3 (NMP EO3) mission to fly in 2003. In response, we proposed to test a large aperture, active optics telescope in geosynchronous orbit. This would flight-qualify new technologies for both Earth and Space science: 1) a future instrument with LANDSAT image resolution and radiometric quality watching continuously from geosynchronous station, and 2) the Next Generation Space Telescope (NGST) for deep space imaging. Six enabling technologies were to be flight-qualified: 1) a 3-meter, lightweight segmented primary mirror, 2) mirror actuators and mechanisms, 3) a deformable mirror, 4) coarse phasing techniques, 5) phase retrieval for wavefront control during stellar viewing, and 6) phase diversity for wavefront control during Earth viewing. Three enhancing technologies were to be flight- validated: 1) mirror deployment and latching mechanisms, 2) an advanced microcontroller, and 3) GPS at GEO. In particular, two wavefront sensing algorithms, phase retrieval by JPL and phase diversity by ERIM International, were to sense optical system alignment and focus errors, and to correct them using high-precision mirror mechanisms. Active corrections based on Earth scenes are challenging because phase diversity images must be collected from extended, dynamically changing scenes. In addition, an Earth-facing telescope in GEO orbit is subject to a powerful diurnal thermal and radiometric cycle not experienced by deep-space astronomy. The Horizon proposal was a bare-bones design for a lightweight large-aperture, active optical system that is a practical blend of science requirements, emerging technologies, budget constraints, launch vehicle considerations, orbital mechanics, optical hardware, phase-determination algorithms, communication strategy, computational burdens, and first-rate cooperation among earth and space scientists, engineers and managers. This manuscript presents excerpts from the Horizon proposal's sections that describe the Earth science requirements, the structural -thermal-optical design, the wavefront sensing and control, and the on-orbit validation.

Chesters, Dennis↗

The Circumstellar Imager: Direct detection of extra-solar planetary systems

The Astrometric Imaging Telescope (AIT) is designed to probe the circumstellar environment by both direct imaging and indirect astrometric measurements. The Circumstellar Imager (CI) is a coronagraphic camera and is the direct imaging component of the AIT. The CI is designed to obtain high-sensitivity images of the circumstellar region. It provides crucial non-inferential information relating to the frequency, origin, and evolution of planetary systems and all forms of circumstellar matter. Such imaging is usually limited by the scattered and diffracted light halos of the star itself, which are greatly suppressed in the CI by mating a novel high-efficiency coronagraph with a phase-compensated optical system. For faint point sources in the circumstellar region, the CI will have a sensitivity in excess of 5 magnitudes fainter than the as-designed Hubble Space Telescope (HST). Laboratory data are shown for the coronagraph, which, in a diffraction-limited environment, is capable of suppressing the stellar diffraction sidelobes by several orders of magnitude without significant sacrifice of field of view. In order to realize the high rejection levels inherent in the coronagraph design, it is necessary to limit scatter in the optical systems, imposing a mid-spatial frequency figure error requirement an order of magnitude smaller than that of the HST. Experimental data directed toward meeting this requirement are also shown.

Ftaclas, Christ↗

Active Optical Control with Machine Learning: A Proof of Concept for the Vera C. Rubin Observatory

Abstract The Active Optics System of the Vera C. Rubin Observatory (Rubin) uses information provided by four wave front sensors to determine deviations between the reconstructed wave front and the ideal wave front. The observed deviations are used to adjust the control parameters of the optical system to maintain image quality across the 3.°5 field of view. The baseline approach from the project is to obtain amplitudes of the Zernike polynomials describing the distorted wave front from out-of-focus images collected by the wave front sensors. These Zernike amplitudes are related via an “influence matrix” to the control parameters necessary to correct the wave front. In this paper, we use deep-learning methods to extract the control parameters directly from the images captured by the wave front sensors. Our neural net model uses anti-aliasing pooling to boost performance, and a domain-specific loss function to aid learning and generalization. The accuracy of the control parameters derived from our model exceeds Rubin requirements even in the presence of full-moon background levels and mis-centering of reference stars. Although the training process is time consuming, model evaluation requires only a few milliseconds. This low latency should allow for the correction of the optical configuration during the readout and slew interval between successive exposures.

Astronomy & Astrophysics↗

Lens alignment system and method

A lens alignment system and method is disclosed. The disclosed system/method integrates one or more lens retaining members/tubes (LRM/LRT) and focal length spacers (FLS) each comprising a metallic material product (MMP) specifically manufactured to have a thermal expansion coefficient (TEC) in a predetermined range via selection of the individual MMP materials and an associated MMP manufacturing process providing for controlled TEC. This controlled LRM/LRT TEC enables a plurality of optical lenses (POL) fixed along a common optical axis (COA) by the LRM/LRT to maintain precise interspatial alignment characteristics that ensure consistent and/or controlled series focal length (SFL) within the POL to generate a thermally neutral optical system (TNOS). Integration of the POL using this LRM/LRT/FLS lens alignment system reduces the overall TNOS implementation cost, reduces the overall TNOS mass, reduces TNOS parts component count, and increases the reliability of the overall optical system.

Monroe, James Alan↗

Phase-Shifting Zernike Interferometer Wavefront Sensor

The canonical Zernike phase-contrast technique1,2,3,4 transforms a phase object in one plane into an intensity object in the conjugate plane. This is done by applying a static pi/2 phase shift to the central core (approx. lambda/D) of the PSF which is intermediate between the input and output planes. Here we present a new architecture for this sensor. First, the optical system is simple and all reflective. Second, the phase shift in the central core of the PSF is dynamic and or arbitrary size. This common-path, all-reflective design makes it minimally sensitive to vibration, polarization and wavelength. We review the theory of operation, describe the optical system, summarize numerical simulations and sensitivities and review results from a laboratory demonstration of this novel instrument

wavefront sensing↗

Automated Optically Guided System for Chemical Analysis of Single Plant and Algae Cells Using Laser Microdissection/Liquid Vortex Capture/Mass Spectrometry

Current analytical methods are not capable of providing rapid, sensitive, and comprehensive chemical analysis of a wide range of cellular constitutes of single cells (e.g., lipids, metabolites, proteins, etc.) from dispersed cell suspensions and thin tissues. This capability is important for a number of critical applications, including discovery of cellular mechanisms for coping with chemical or environmental stress and cellular response to drug treatment, to name a few. Here we introduce an optically guided platform and methodology for rapid, automated recognition, sampling, and chemical analysis of surface confined individual cells utilizing a novel hybrid laser capture microdissection/liquid vortex capture/mass spectrometry system. The system enabled automated analysis of single cells by reliably detecting and sampling them either through laser ablation from a glass microscope slide or by cutting the entire cell out of a poly(ethylene naphthalate)-coated membrane substrate that the cellular sample is deposited on. Proof of principle experiments were performed using thin tissues of Allium cepa and cultured Euglena gracilis and Phacus cell suspensions as model systems for single cell analysis using the developed method. Reliable, hands-off laser ablation sampling coupled to liquid vortex capture/mass spectrometry analysis was conducted for hundreds of individual Allium cepa cells in connected tissue. In addition, more than 300 individual Euglena gracilis and Phacus cells were analyzed automatically and sampled using laser microdissection sampling with the same liquid vortex capture/mass spectrometry analysis system. Principal component analysis-linear discriminant analysis, applied to each mass spectral dataset, was used to determine the accuracy of differentiation of the different algae cell lines.

59 BASIC BIOLOGICAL SCIENCES↗

Phase-Shifting Zernike Interferometer Wavefront Sensor

The canonical Zernike phase-contrast technique transforms a phase object in one plane into an intensity object in the conjugate plane. This is done by applying a static pi/2 phase shift to the central core (approx. lambda/diameter) of the PSF which is intermediate between the input and output plane. Here we present a new architecture for this sensor. First, the optical system is simple and all reflective, and second the phase shift in the central core of the PSF is dynamic and can be made arbitrarily large. This common-path, all-reflective design makes it minimally sensitive to vibration, polarization and wavelength. We review the theory of operation, describe the optical system, summarize numerical simulations and sensitivities and review results from a laboratory demonstration of this novel instrument.

Zernike phase-contrast↗