Search NASA⌕ Search

SEARCH · Search NASA

Results for “PLATES, FLAT - STRESSES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,009 records · Page 56

A physics-based model for frost buildup under turbulent flow using direct numerical simulations

We present a new model for frost buildup under turbulent (and laminar) flow using direct numerical simulations. The physical model consists of two layers, the air and the frost. The air layer is fully resolved and consists of solving for the velocity, temperature, and vapor mass fraction fields. The frost layer thickness is resolved using conservation of mass and energy. Both phases are dynamically coupled using the immersed boundary method. Three-dimensional simulations are conducted in an open-channel configuration. A number of challenges need to be overcome to make these simulations feasible. First, to enforce far-field conditions of zero gradient and prescribed mean temperature and humidity, a source term is added to the energy and transport equations in the flow solver. Second, the mean frost thickness is subtracted after each time step to ensure a constant mean flow thickness and level of turbulence in the numerical domain. Third, a slow-time acceleration approach, which accelerates the frost buildup by a predetermined factor, is employed to bridge the gap between the fast turbulent and slow frost buildup time scales. Finally, a frost densification scheme is used to overcome the difficulties of vertically varying frost properties. The model is validated by comparing the frost thickness and frost thickness buildup rate over a period of one hour from a cooled flat plate experiment. As a result, both quantities compare favorably with experiments.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Oxide evolution on the SiC layer of TRISO particles during extended air oxidation

Tristructural isotropic (TRISO) fuel particles have been primarily developed for high-temperature gas-cooled nuclear reactors and can be subjected to oxidizing environments for extended periods in an off-normal accident scenario. Surrogate TRISO fuel particles were oxidized in air at 1,000 or 1,100 °C for up to 120 h. Here, the oxide scale morphology and thickness were studied via scanning electron microscopy, focused ion beam, and atomic force microscopy. TRISO particles oxidized at 1,100 °C exhibited a highly crystalline oxide scale, which led to significant cracking and irregularly shaped closed porosity, whereas those oxidized at 1,000 °C possessed a primarily amorphous oxide scale, which contained small, rounded internal pores and no larger defects. The observed phenomena deviated from the expected behavior based on models for oxide growth on flat-plate and fiber SiC. The oxidation kinetics of TRISO fuel particles in high-temperature air were investigated without mechanically deforming the surface and were analyzed with respect to oxide morphology.

36 MATERIALS SCIENCE↗

Friction stir processing: A thermomechanical processing tool for high pressure die cast Al-alloys for vehicle light-weighting

This study uses friction stir processing (FSP) for thermomechanical processing of high-pressure die-casting (HPDC) to modify microstructure and improve mechanical properties. FSP is carried out on two different HPDC aluminum alloys: (a) general-purpose, high-iron, HPDC A380 alloy and (b) premium quality, low-iron HPDC Aural-5 alloy in thin wall, flat plate geometry. Subsequent mechanical testing shows ~30 % and ~65 % enhancement in yield strength and tensile ductility. In addition, FSP leads to ~10 times improvement in fatigue life for A380 alloy and ~70 % improvement in fracture toughness for Aural-5 alloy. These findings emphasize the capability of FSP to modify the microstructure of HPDC Al-alloys-based structural components so that they can demonstrate a good combination of strength, ductility, fracture toughness, and high fatigue properties for long-term durability and reliability.

36 MATERIALS SCIENCE↗

Empirically verified analysis of dual pre-cooling system for hydrogen refuelling station

The dual cooling system at the California State University Los Angeles Hydrogen Research and Fueling Facility is analysed to predict the output hydrogen temperature in different ambient conditions. Initially, the facility was built with a coil chiller T20 cooling, sufficient for occasional fuelings. A flat plate evaporator system was added in series to resolve any issues for multiple fuelings even in the hottest weather. This study was commenced to verify the set points and determine the control requirements for the dual setup in order to inform future designs. A numerical-empirical model of the cooling system was developed by reverse engineering, using the station experimental measurements and database records. The subsystems are characterized separately but validated as a whole system imposing specific and standard operating conditions. The cooling model is tested with different inputs to validate the pre-set parameter variation of the cooling components. Ten scenarios were investigated to evaluate the fueling output parameters, testing two hydrogen temperature input trends (according to the facility initial conditions) and five ambient temperatures (from 15 °C to 35 °C). In closing, the simulation results have confirmed that the hydrogen output temperature remains within the range imposed by the SAE J2601 for each scenario studied, around -22 °C and -25 °C.

08 HYDROGEN↗

Monthly optimum inclination of glass cover and external reflector of a basin type solar still with internal and external reflector

In this report, we present a theoretical analysis of a basin type solar still with internal and external reflectors. The external reflector is a flat plate that extends from the back wall of the still, and can presumably be inclined forwards or backwards according to the month. We have theoretically predicted the daily amount of distillate produced by the still throughout the year, which varies according to the inclination angle of both the glass cover and the external reflector, at 30 N latitude. We found the optimum external reflector inclination for each month for a still with a glass cover inclination of 10-50 deg. The increase in the average daily amount of distillate throughout the year of a still with inclined external reflector with optimum inclination in addition to an internal reflector, compared to a conventional basin type still was predicted to be 29%, 43% or 67% when the glass cover inclination is 10 deg, 30 deg or 50 deg and the length of external reflector is half the still's length. (author)

14 SOLAR ENERGY↗

Integration of transparent insulation materials into solar collector devices

The integration of Transparent Insulation Materials (TIMs) into Flat Plate Collectors (FPCs), Parabolic Trough Collectors (PTCs), and Central Receiver (CR) collectors is studied in this paper. A general model including optical and thermal analyses is developed. The effects of TIM’s properties, such as the emittance, thermal conductivity, extinction coefficient, and thickness, on the collectors’ performance, are analyzed. At low absorber temperatures, performances of traditional-type collectors are relatively high. The efficiency of these collectors reduces dramatically at high temperatures due to the increment in heat losses. The incorporation of a TIM decreases thermal losses, leading to higher collectors’ efficiencies at high absorber temperatures. The main goal of this study is to determine the critical operation temperature from which thermal losses reduction overcome the optical efficiency losses due to a TIM integration. In general, for high performance collectors, TIMs are characterized by low emittances and thermal con- ductivities, high transmittances, and low extinction coefficients.

14 SOLAR ENERGY↗

The cost savings potential of controlling solar thermal collectors with storage for time-of-use electricity rates

Homes and commercial buildings account for roughly 40% of U.S. energy consumption. A significant portion of this energy consumption, and therefore utility cost, comes from domestic hot-water use. Solar collectors such as flat plate collectors, evacuated tubes, and combined photovoltaic/thermal panels, are renewable options that collect thermal energy and could help reduce utility costs. Hot water is generated by pumping a working fluid through the solar collector, where the fluid captures thermal energy via absorbed solar radiation incident on the collector surface. The collection of heat coincides with the availability of solar radiation, but the best time to use this thermal energy depends on the utility rate at a given time, which often changes throughout the day. In this work, we implement and simulate a control strategy using Transient System Simulation Tool (TRNSYS) that reduces utility costs by controlling when the system stores and uses thermal energy based on solar availability and time-of-use electricity rates. Our modeled results show that the control strategy can reduce utility costs associated with using hot water between 3% and 30%. Here, we also show how the on-peak utility rates, the size and type of the solar collectors, and the location's climate impact the results.

14 SOLAR ENERGY↗

Numerical investigation of the role of free-stream turbulence in boundary-layer separation

The aerodynamic performance of lifting surfaces operating at low Reynolds number conditions is impaired by laminar separation. In most cases, transition to turbulence occurs in the separated shear layer as a result of a series of strong hydrodynamic instability mechanisms. Although the understanding of these mechanisms has been significantly advanced over the past decades, key questions remain unanswered about the influence of external factors such as free-stream turbulence (FST) and others on transition and separation. The present study is driven by the need for more accurate predictions of separation and transition phenomena in ‘real world’ applications, where elevated levels of FST can play a significant role (e.g. turbomachinery). Numerical investigations have become an integral part in the effort to enhance our understanding of the intricate interactions between separation and transition. Due to the development of advanced numerical methods and the increase in the performance of supercomputers with parallel architecture, it has become feasible for low Reynolds number application ( $O(10^{5})$ ) to carry out direct numerical simulations (DNS) such that all relevant spatial and temporal scales are resolved without the use of turbulence modelling. Because the employed high-order accurate DNS are characterized by very low levels of background noise, they lend themselves to transition research where the amplification of small disturbances, sometimes even growing from numerical round-off, can be examined in great detail. When comparing results from DNS and experiment, however, it is beneficial, if not necessary, to increase the background disturbance levels in the DNS to levels that are typical for the experiment. For the current work, a numerical model that emulates a realistic free-stream turbulent environment was adapted and implemented into an existing Navier–Stokes code based on a vorticity–velocity formulation. The role FST plays in the transition process was then investigated for a laminar separation bubble forming on a flat plate. FST was shown to cause the formation of the well-known Klebanoff mode that is represented by streamwise-elongated streaks inside the boundary layer. Increasing the FST levels led to accelerated transition, a reduction in bubble size and better agreement with the experiments. Moreover, the stage of linear disturbance growth due to the inviscid shear-layer instability was found to not be ‘bypassed’.

Mechanics↗

Passively Sampled Environmental Films Show Geographic Variability and Host a Variety of Microorganisms

Environmental films are ubiquitous coatings that form on virtually all surfaces exposed to the troposphere. This work analyzes large molecular weight species in native environmental films acquired at three collection sites in the vicinity of Iowa City, Iowa, USA that include an urban residence, a wooded area, and a metropolitan building rooftop. The films are developed for up to twelve months on polished silicon wafer substrates housed in flat-plate passive samplers. Film composition was assessed by Fourier transform ion cyclotron resonance secondary ion mass spectrometry (FTICR-SIMS), and spatially resolved chemical morphology was analyzed via timeof- flight secondary ion mass spectrometry (ToF-SIMS) imaging. Mass analysis spanning up to m/z 2,000 included detection of a variety of organic and inorganic compounds. We characterize MS data with PCA to identify variability between the collection sites and the respective films generated therein, where we detected a variety of organic and biotically generated species consistent with fungal and bacterial microorganisms. Here, the film collection site as well as deposition time contribute to spectral variability, suggesting that geographic location as well as seasonal diversity may affect composition. SIMS analyses were complemented with microscopy and SYBR-Safe staining to highlight biological microorganisms within the films, which include evidence of fungi, protozoa, and bacteria. SIMS imaging also reveals domains concentrated with fragments indicative of proteinaceous macromolecules and microbial biomass, characteristic of biological presence within the film.

42 ENGINEERING↗

Six-junction III–V solar cells with 47.1% conversion efficiency under 143 Suns concentration

Single-junction flat-plate terrestrial solar cells are fundamentally limited to about 30% solar-to-electricity conversion efficiency, but multiple junctions and concentrated light make much higher efficiencies practically achievable. Until now, four-junction III–V concentrator solar cells have demonstrated the highest solar conversion efficiencies. Here, we demonstrate 47.1% solar conversion efficiency using a monolithic, series-connected, six-junction inverted metamorphic structure operated under the direct spectrum at 143 Suns concentration. Furthermore, when tuned to the global spectrum, a variation of this structure achieves a 1-Sun global efficiency of 39.2%. Nearly optimal bandgaps for six junctions were fabricated using alloys of III–V semiconductors. To develop these junctions, it was necessary to minimize threading dislocations in lattice-mismatched III–V alloys, prevent phase segregation in metastable quaternary III–V alloys and understand dopant diffusion in complex structures. Further reduction of the series resistance within this structure could realistically enable efficiencies over 50%.

14 SOLAR ENERGY↗

Correcting hot-wire measurements of stream-wise turbulence intensity in boundary layers

The current experimental activity aimed at resolving the scaling of stream-wise turbulence intensity profiles uu{sup +}(y{sup +}) with Reynolds number in turbulent flat plate boundary layers has brought the largely unresolved issue of correcting systematic errors in hot-wire measurements of uu{sup +}(y{sup +}) into focus. Here, a heuristic scheme is proposed to generate unique uu{sup +}(y{sup +};Re{sub {delta}{sup *}}) profiles from data obtained with single hot wires of widely different length, aspect ratio and construction over a large Reynolds number range of 4000 < or approx. Re{sub {delta}{sup *}} < or approx. 50 000. A comparison with LDA data and other checks suggest that the present correction scheme produces uu{sup +}(y{sup +};Re{sub {delta}{sup *}}) profiles close to the (unknown) true profiles.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Three-dimensional effects of curved plasma actuators in quiescent air

This paper presents results on a new class of curved plasma actuators for the inducement of three-dimensional vortical structures. The nature of the fluid flow inducement on a flat plate, in quiescent conditions, due to four different shapes of dielectric barrier discharge (DBD) plasma actuators is numerically investigated. The three-dimensional plasma kinetic equations are solved using our in-house, finite element based, multiscale ionized gas (MIG) flow code. Numerical results show electron temperature and three dimensional plasma force vectors for four shapes, which include linear, triangular, serpentine, and square actuators. Three-dimensional effects such as pinching and spreading the neighboring fluid are observed for serpentine and square actuators. The mechanisms of vorticity generation for DBD actuators are discussed. Also the influence of geometric wavelength ({lambda}) and amplitude ({Lambda}) of the serpentine and square actuators on vectored thrust inducement is predicted. This results in these actuators producing significantly better flow mixing downstream as compared to the standard linear actuator. Increasing the wavelengths of serpentine and square actuators in the spanwise direction is shown to enhance the pinching effect giving a much higher vertical velocity. On the contrary, changing the amplitude of the curved actuator varies the streamwise velocity significantly influencing the near wall jet. Experimental data for a serpentine actuator are also reported for validation purpose.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Considerations for How to Rate CPV

The concentrator photovoltaic (CPV) industry is introducing multiple products into the marketplace, but, as yet, the; community has not embraced a unified method for assessing a nameplate rating. The choices of whether to use 850,; 900, or 1000 W/m2 for the direct-normal irradiance and whether to link the rating to ambient or cell temperature will; affect how CPV modules are rated and compared with other technologies. This paper explores the qualitative and; quantitative ramifications of these choices using data from two multi-junction CPV modules and two flat-plate; modules.

14 SOLAR ENERGY↗

Influence of the airflow speed along transmission lines on the DC corona discharge loss, using finite element approach

Corona discharge is of great interest from the physical point of view and due to its numerous practical applications in industry and especially one of the most important sources of loss in the high voltage transmission lines. This paper provides guidelines for the amount of electric loss caused by corona phenomenon occurred around a DC high voltage wire placed between two flat plates and influence of wind speed rate on the amount of corona loss using COMSOL Multiphysics. So electric potential distribution patterns and charge density diffusion around the wire are studied in this article.

42 ENGINEERING↗

Thermal neutron diffraction determination of the magnetic structure of EuCu{sub 2}Ge{sub 2}

The magnetic structure of EuCu{sub 2}Ge{sub 2} has been determined by flat-plate neutron powder diffraction. Two magnetic phases are present in the neutron diffraction pattern at 3.5 K. They have the same moment, within error, and a common transition temperature. Both {sup 151}Eu and {sup 153}Eu Mössbauer spectroscopy show that the two magnetic phases belong to the same crystallographic phase. Both phases can be modelled by planar helimagnetic structures: one with a propagation vector of [0.654(1), 0, 0], the other with a propagation vector of [0.410(1), 0.225(1), 0].

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Development of an ultrasonic pulse-echo (UPE) technique for aircraft icing studies

Aircraft operating in some cold weather conditions face the risk of icing. Icing poses a threat to flight safety and its management is expensive. Removing light frost on a clear day from a medium-size business jet can cost $300, heavy wet snow removal can cost $3,000 and removal of accumulated frozen/freezing rain can cost close to $10,000. Understanding conditions that lead to severe icing events is important and challenging. When an aircraft or rotorcraft flies in a cold climate, some of the super cooled droplets impinging on exposed aircraft surfaces may flow along the surface prior to freezing and give various forms and shapes of ice. The runback behavior of a water film on an aircraft affects the morphology of ice accretion and the rate of formation. In this study, we report the recent progress to develop an Ultrasonic Pulse-Echo (UPE) technique to provide real-time thickness distribution measurements of surface water flows driven by boundary layer airflows for aircraft icing studies. A series of initial experimental investigations are conducted in an ice wind tunnel employing an array of ultrasonic transducers placed underneath the surface of a flat plate. The water runback behavior on the plate is evaluated by measuring the thickness profile variation of the water film along the surface by using the UPE technique under various wind speed and flow rate conditions.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Spectrum sensitivity, energy yield, and revenue prediction of PV and CPV modules

Impact on module performance of spectral irradiance variation has been determined for III-V multijunctions compared against the four most common flat-plate module types (cadmium telluride, multicrystalline silicon, copper indium gallium selenide, and monocrystalline silicon. Hour-by-hour representative spectra were generated using atmospheric variables for Albuquerque, New Mexico, USA. Convolution with published values for external quantum efficiency gave the predicted current output. When combined with specifications of commercial PV modules, energy yield and revenue were predicted. This approach provides a means for optimizing PV module design based on various site-specific temporal variables.

14 SOLAR ENERGY↗