Search NASA⌕ Search

SEARCH · Search NASA

Results for “POWER FACTOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,009 records · Page 56

Updating Human Factors Engineering Guidelines for Conducting Safety Reviews of Nuclear Power Plants

The U.S. Nuclear Regulatory Commission (NRC) reviews the human factors engineering (HFE) programs of applicants for nuclear power plant construction permits, operating licenses, standard design certifications, and combined operating licenses. The purpose of these safety reviews is to help ensure that personnel performance and reliability are appropriately supported. Detailed design review procedures and guidance for the evaluations is provided in three key documents: the Standard Review Plan (NUREG-0800), the HFE Program Review Model (NUREG-0711), and the Human-System Interface Design Review Guidelines (NUREG-0700). These documents were last revised in 2007, 2004 and 2002, respectively. The NRC is committed to the periodic update and improvement of the guidance to ensure that it remains a state-of-the-art design evaluation tool. To this end, the NRC is updating its guidance to stay current with recent research on human performance, advances in HFE methods and tools, and new technology being employed in plant and control room design. This paper describes the role of HFE guidelines in the safety review process and the content of the key HFE guidelines used. Then we will present the methodology used to develop HFE guidance and update these documents, and describe the current status of the update program.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

PUF-Based Two-Factor Authentication Protocol for Securing the Power Grid Against Insider Threat

Recent advances in smart grid technologies have enabled additional distributed control paradigms that allow more efficient and reliable operation. However, this creates new security concerns for the grid, such as attackers using spoofed grid control devices to generate false measurements. This paper introduces a two-factor authentication protocol leveraging standard public-key cryptography as one authentication factor and a hardware-based fingerprint, known as a Physical Unclonable Function, as a second authentication factor. This protocol incurs a small overhead and prevents cyber-attacks even when an adversary is able to compromise the cryptographic keys stored in the non-volatile memory of an intelligent control device.

42 ENGINEERING↗

Photovoltaic and Energy Efficiency Systems Installation (Final Technical Report)

Hackensack University Medical Center's major initiative to create a cleaner healthier and safer environment for patients, employees and the community served by the medical center is built on its commitment to protect the environment and conserve precious energy resources. Since 2004 the Medical Center launched a long term campaign to temper the negative environmental impact of proposed and existing new construction at the medical center and to improve campus wide overall energy efficiency. The plan was to begin by implementing a number of innovative and eco-friendly enhancements to the Gabrellian Women's and Children's Pavilion, in construction at the time, which would lead to Certification by the US Green Building Councils Leadership & Environmental Design (LEED) program. In addition the medical center would evaluate the feasibility of implementing a photovoltaic system in the new construction (in development and planned) to provide clean pollution free electricity. The steps taken to achieve this included conducting a feasibility study complete with architectural and engineering assessments to determine the potential for implementation of a photovoltaic system on the campus and also to conduct an energy survey that would focus on determining specific opportunities and upgrades that would lead to a healthier energy efficient interior environment at the medical center. The studies conducted by the medical center to determine the viability of installing a photovoltaic system identified two key issues that factored into leaderships decision not to implement the solar powered system. These factors were related to the advanced phase of construction of the women's and children's pavilion and the financial considerations to redesign and implement in the ambulatory cancer center. The medical center, in spite of their inability to proceed with the solar aspect of the project upheld their commitment to create a healthier environment for the patients and the community. To achieve a healthier energy efficient interior environment the medical center made substantive upgrades and improvements to the HVAC, plumbing electrical and other operating systems. Measures that were implemented range from use of lighting and plumbing fixture sensors , to reduce electrical and water usage, to use of refrigerants containing hydrochlorofluorocarbons (HCFCs) which cause significantly less depletion of the ozone layer than the refrigerants more commonly used. Additional appropriate energy efficiency component upgrades include the installation of Chiller plants with variable frequency drives (VFDs) and harmonic filters, high efficiency motors, solar window glazing, and lighting/motion sensors.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Photovoltaic and Energy Efficiency Systems Installation

Hackensack University Medical Center's major initiative to create a cleaner healthier and safer environment for patients, employees and the community served by the medical center is built on its commitment to protect the environment and conserve precious energy resources. Since 2004 the Medical Center launched a long term campaign to temper the negative environmental impact of proposed and existing new construction at the medical center and to improve campus wide overall energy efficiency. The plan was to begin by implementing a number of innovative and eco-friendly enhancements to the Gabrellian Women's and Children's Pavilion, in construction at the time, which would lead to Certification by the US Green Building Councils Leadership & Environmental Design (LEED) program. In addition the medical center would evaluate the feasibility of implementing a photovoltaic system in the new construction (in development and planned) to provide clean pollution free electricity. The steps taken to achieve this included conducting a feasibility study complete with architectural and engineering assessments to determine the potential for implementation of a photovoltaic system on the campus and also to conduct an energy survey that would focus on determining specific opportunities and upgrades that would lead to a healthier energy efficient interior environment at the medical center. The studies conducted by the medical center to determine the viability of installing a photovoltaic system identified two key issues that factored into leaderships decision not to implement the solar powered system. These factors were related to the advanced phase of construction of the women's and children's pavilion and the financial considerations to redesign and implement in the ambulatory cancer center. The medical center, in spite of their inability to proceed with the solar aspect of the project upheld their commitment to create a healthier environment for the patients and the community. To achieve a healthier energy efficient interior environment the medical center made substantive upgrades and improvements to the HVAC, plumbing electrical and other operating systems. Measures that were implemented range from use of lighting and plumbing fixture sensors, to reduce electrical and water usage, to use of refrigerants containing hydrochlorofluorocarbons (HCFCs) which cause significantly less depletion of the ozone layer than the refrigerants more commonly used. Additional appropriate energy efficiency component upgrades include the installation of Chiller plants with variable frequency drives (VFDs) and harmonic filters, high efficiency motors, solar window glazing, and lighting/motion sensors.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Should Astronauts throw out their Trash? And if so, How?

We don’t think much about taking out the trash on Earth, but in space, it requires some thought. Should it even be thrown overboard? Besides the implications of littering in space, there are also practical considerations of whether waste materials can be reused for other purposes onboard or do they reduce mission efficiency. In a previous study, gasifying and venting trash along the way to Mars was found to noticeably reduce propellant needs and launch mass of the spacecraft, whereas keeping processed trash on board in the form of radiation shielding tiles would significantly lower the crew’s radiation dose during a solar particle event. The latest human exploration mission proposals will be considered with an eye toward answering the questions, “Should Astronauts throw out their Trash?” and “If so, what is the best way?” Besides reviewing the propulsion and radiation shielding aspects of the question, equivalent system mass factors of mass, power, volume, and crew time, as well as human factors, like smell, will be studied. Disposal options include jettison of an entire module containing waste, regular disposal of trash via an airlock, or gasifying waste products for easier disposal or reuse. Jettison via an airlock could take many forms, from “taking out the trash” on a spacewalk to launching trash tiles or pods with different mechanisms. Likewise, the “trash-to-gas” concept, which would allow for overboard venting via a pipe, has many thermochemical processes to choose from, each with their own pros and cons. Unraveling these various tradeoff studies is the goal of this paper.

trash↗

The impact of wind, solar, and other factors on the decline in wholesale power prices in the United States

Across multiple organized wholesale power markets in the United States, annual average prices declined by 19–64 dollars per MWh between 2008 and 2017 while retirements of thermal power plants accelerated. Several prominent changes over the last decade are often discussed as contributors to this decline in prices. These include growth in wind and solar, a reduction in the price of natural gas, and weakened load growth. Here we construct a fundamental supply curve model for each of seven organized wholesale market regions and use counterfactual simulations to assess the degree to which wind and solar—among other factors—have influenced wholesale electricity prices. We find that growth in wind and solar since 2008 reduced average annual wholesale electricity prices by less than 3 dollars per MWh. In contrast the decline in natural gas prices reduced wholesale prices by 7–53 dollars per MWh, depending on the region. This suggests that recent thermal-plant retirements in the U.S. are primarily due to low natural gas prices, not growth in wind and solar. Fully isolating the impact of individual factors, however, is limited by non-linear interactions between factors.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Some aspects of the decommissioning of nuclear power plants

The major factors influencing the choice of a national concept for the decommissioning of nuclear power plants are examined. The operating lifetimes of power generating units with nuclear reactors of various types (VVER-1000, VVER-440, RBMK-1000, EGP-6, and BN-600) are analyzed. The basic approaches to decommissioning Russian nuclear power plants and the treatment of radioactive waste and spent nuclear fuel are discussed. Major aspects of the ecological and radiation safety of personnel, surrounding populations, and the environment during decommissioning of nuclear installations are identified.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Role of poloidal E × B drift in divertor heat transport in DIII‐D

Abstract Simulations for DIII‐D high confinement mode plasmas with the multifluid code UEDGE show a strong role of poloidal E × B drifts on divertor heat transport, challenging the paradigm of conduction‐limited scrape‐off layer (SOL) transport. While simulations with reduced drift magnitude are well aligned with the assumption that electron heat conduction dominates the SOL heat transport, simulations with drifts predict that the poloidal convective E × B heat transport dominates over electron heat conduction in both attached and detached conditions. As poloidal E × B flow propagates across magnetic field lines, poloidal transport with shallow magnetic pitch angles can reach values that are of the same order as would be provided by sonic flows parallel to the field lines. These flows can lead to strong convection‐dominated divertor heat transport, increasing the poloidal volume of radiative power front, consistent with previous measurements at DIII‐D. Due to these convective flows, the Lengyel integral approach, assuming zero convective fraction, is expected to provide a pessimistic estimate for the radiative capability of impurities in the divertor. For the DIII‐D simulations shown here, the Lengyel integral approach underestimates the radiated power by a factor of 6, indicating that, for reliable DIII‐D divertor power exhaust predictions, full two‐dimensional (2D) calculations, including drifts, would be necessary.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Visualizing Wind Farm Wakes Using SCADA Data

As wind farms scale to include more and more turbines, questions about turbine wake interactions become increasingly important. Turbine wakes reduce wind speed and downwind turbines suffer decreased performance. The cumulative effect of the wakes throughout a wind farm will therefore decrease the performance of the entire farm. These interactions are dynamic and complicated, and it is difficult to quantify the overall effect of the wakes. This problem has attracted some attention in terms of computational modelling for siting turbines on new farms, but less attention in terms of empirical studies and performance validation of existing farms. In this report, Supervisory Control and Data Acquisition (SCADA) data from an existing wind farm is analyzed in order to explore methods for documenting wake interactions. Visualization techniques are proposed and used to analyze wakes in a 67 turbine farm. The visualizations are based on directional analysis using power measurements, and can be considered to be normalized capacity factors below rated power. Wind speed measurements are not used in the analysis except for data pre-processing. Four wake effects are observed; including wake deficit, channel speed up, and two potentially new effects, single and multiple shear point speed up. In addition, an attempt is made to quantify wake losses using the same SCADA data. Power losses for the specific wind farm investigated are relatively low, estimated to be in the range of 3-5%. Finally, a simple model based on the wind farm geometrical layout is proposed. Key parameters for the model have been estimated by comparing wake profiles at different ranges and making some ad hoc assumptions. A preliminary comparison of six selected profiles shows excellent agreement with the model. Where discrepancies are observed, reasonable explanations can be found in multi-turbine speedup effects and landscape features, which are yet to be modelled.

17 WIND ENERGY↗

Hetero-nanostructured materials for high-power lithium ion batteries

The development of high technology electrical devices increased the importance of higher power density or higher capacity at high current density. Especially, rapid charge/discharge issues remain problematic for electric vehicle commercialization. After extensive investigation, researchers introduced hetero-nanostructured materials to the field of lithium ion batteries (LIBs), aiming to enhance the power density or improve the capacity at high current density and life cycle capability. Hetero-nanostructured materials consist of current collectors and directly attached active nanomaterials. Carbon, carbon nanotube (CNT), graphene, Nickel (Ni), Copper (Cu) and Aluminum (Al) were used for current collector, aiming to improve the electron transfer and the cyclability, due to high electrical conductivity and superior buffering effects. Also, Hetero-nanostructure can produce a favorable lithium diffusion condition by creating a lithium diffusion pathway. This article presents an explanation of important factors for high power density or high capacity at high current density. It summarizes the capacity of electrode materials at high current density, including structural descriptions and material types.

Lee, Jaewon↗

H{sup -} radio frequency source development at the Spallation Neutron Source

The Spallation Neutron Source (SNS) now routinely operates nearly 1 MW of beam power on target with a highly persistent {approx}38 mA peak current in the linac and an availability of {approx}90%. H{sup -} beam pulses ({approx}1 ms, 60 Hz) are produced by a Cs-enhanced, multicusp ion source closely coupled with an electrostatic low energy beam transport (LEBT), which focuses the 65 kV beam into a radio frequency quadrupole accelerator. The source plasma is generated by RF excitation (2 MHz, {approx}60 kW) of a copper antenna that has been encased with a thickness of {approx}0.7 mm of porcelain enamel and immersed into the plasma chamber. The ion source and LEBT normally have a combined availability of {approx}99%. Recent increases in duty-factor and RF power have made antenna failures a leading cause of downtime. This report first identifies the physical mechanism of antenna failure from a statistical inspection of {approx}75 antennas which ran at the SNS, scanning electron microscopy studies of antenna surface, and cross sectional cuts and analysis of calorimetric heating measurements. Failure mitigation efforts are then described which include modifying the antenna geometry and our acceptance/installation criteria. Progress and status of the development of the SNS external antenna source, a long-term solution to the internal antenna problem, are then discussed. Currently, this source is capable of delivering comparable beam currents to the baseline source to the SNS and, an earlier version, has briefly demonstrated unanalyzed currents up to {approx}100 mA (1 ms, 60 Hz) on the test stand. In particular, this paper discusses plasma ignition (dc and RF plasma guns), antenna reliability, magnet overheating, and insufficient beam persistence.

43 PARTICLE ACCELERATORS↗

Optimal light beams and mirror shapes for future LIGO interferometers

We report the results of a recent search for the lowest value of thermal noise that can be achieved in LIGO by changing the shape of mirrors, while fixing the mirror radius and maintaining a low diffractional loss. The result of this minimization is a beam with thermal noise a factor of 2.32 (in power) lower than previously considered Mesa Beams and a factor of 5.45 (in power) lower than the Gaussian beams employed in the current baseline design. Mirrors that confine these beams have been found to be roughly conical in shape, with an average slope approximately equal to the mirror radius divided by arm length, and with mild corrections varying at the Fresnel scale. Such a mirror system, if built, would impact the sensitivity of LIGO, increasing the event rate of observing gravitational waves in the frequency range of maximum sensitivity roughly by a factor of 3 compared to an Advanced LIGO using Mesa beams (assuming all other noises remain unchanged). We discuss the resulting beam and mirror properties and study requirements on mirror tilt, displacement, and figure error, in order for this beam to be used in LIGO detectors.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A VISION of Advanced Nuclear System Cost Uncertainty

VISION (VerifIable fuel cycle SImulatiON) is the Advanced Fuel Cycle Initiative’s and Global Nuclear Energy Partnership Program’s nuclear fuel cycle systems code designed to simulate the US commercial reactor fleet. The code is a dynamic stock and flow model that tracks the mass of materials at the isotopic level through the entire nuclear fuel cycle. As VISION is run, it calculates the decay of 70 isotopes including uranium, plutonium, minor actinides, and fission products. VISION.ECON is a sub-model of VISION that was developed to estimate fuel cycle and reactor costs. The sub-model uses the mass flows generated by VISION for each of the fuel cycle functions (referred to as modules) and calculates the annual cost based on cost distributions provided by the Advanced Fuel Cycle Cost Basis Report1. Costs are aggregated for each fuel cycle module, and the modules are aggregated into front end, back end, recycling, reactor, and total fuel cycle costs. The software also has the capability to perform system sensitivity analysis. This capability may be used to analyze the impacts on costs due to system uncertainty effects. This paper will provide a preliminary evaluation of the cost uncertainty affects attributable to 1) key reactor and fuel cycle system parameters and 2) scheduling variations. The evaluation will focus on the uncertainty on the total cost of electricity and fuel cycle costs. First, a single light water reactor (LWR) using mixed oxide fuel is examined to ascertain the effects of simple parameter changes. Three system parameters; burnup, capacity factor and reactor power are varied from nominal cost values and the affect on the total cost of electricity is measured. These simple parameter changes are measured in more complex scenarios 2-tier systems including LWRs with mixed fuel and fast recycling reactors using transuranic fuel. Other system parameters are evaluated and results will be presented in the paper. Secondly, the uncertainty due to variation in scheduling effects is evaluated. For example, economic impacts due to increased nuclear energy growth rates and speed-ups in deployment of fuel cycle facilities and fast reactors. Preliminary results show that significant variations in the costs of the scenarios can result from variations in burnup, capacity factor and reactor power. The paper will include new results from analysis of additional system variables and due to scheduling dynamics. Reference 1. Shropshire, D.E. et al, 2007, Advanced Fuel Cycle Cost Basis, INL/EXT-07-12107, April 2007.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Damage Profile and Ion Distribution of Slow Heavy Ions in Compounds

Slow heavy ions inevitably produce a significant concentration of defects and lattice disorder in solids during their slowing-down process via ion-solid interactions. For irradiation effects research and many industrial applications, atomic defect production, ion range and doping concentration are commonly estimated by the Stopping and Range of Ions in Matter (SRIM) code. In this study, ion-induced damage and projectile ranges of low energy Au ions in SiC are determined using complementary ion beam and microscopy techniques. Considerable errors in both disorder profile and ion range predicted by the SRIM code indicate an overestimation of the electronic stopping power, by a factor of 2 in most cases, in the energy region up to 25 keV/nucleon. Such large discrepancies are also observed for slow heavy ions, including Pt, Au and Pb ions, in other functional materials, such as GaN, AlN and SrTiO3. Due to the importance of these materials for advanced device and nuclear applications, better electronic stopping cross section predictions, based on a reciprocity principle developed by Sigmund, is suggested with fitting parameters for possible improvement.

74 ATOMIC AND MOLECULAR PHYSICS↗

Subleading power corrections to heavy quarkonium production in QCD factorization approach

We report the current understanding of heavy quarkonium production at high transverse momentum ($p_T$) in hadronic collisions in terms of QCD factorization. In this presentation, we highlight the role of subleading power corrections to heavy quarkonium production, which are essential to describe the $p_T$ spectrum of quarkonium at a relatively lower $p_T$. We also introduce prescription to match QCD factorization to fixed-order NRQCD factorization calculations for quarkonium production at low $p_T$.

Lee, Kyle↗

Applying Human Factors Evaluation and Design Guidance to a Nuclear Power Plant Digital Control System

The United States (U.S.) nuclear industry, like similar process control industries, has moved toward upgrading its control rooms. The upgraded control rooms typically feature digital control system (DCS) displays embedded in the panels. These displays gather information from the system and represent that information on a single display surface. In this manner, the DCS combines many previously separate analog indicators and controls into a single digital display, whereby the operators can toggle between multiple windows to monitor and control different aspects of the plant. The design of the DCS depends on the function of the system it monitors, but revolves around presenting the information most germane to an operator at any point in time. DCSs require a carefully designed human system interface. This report centers on redesigning existing DCS displays for an example chemical volume control system (CVCS) at a U.S. nuclear power plant. The crucial nature of the CVCS, which controls coolant levels and boration in the primary system, requires a thorough human factors evaluation of its supporting DCS. The initial digital controls being developed for the DCSs tend to directly mimic the former analog controls. There are, however, unique operator interactions with a digital vs. analog interface, and the differences have not always been carefully factored in the translation of an analog interface to a replacement DCS. To ensure safety, efficiency, and usability of the emerging DCSs, a human factors usability evaluation was conducted on a CVCS DCS currently being used and refined at an existing U.S. nuclear power plant. Subject matter experts from process control engineering, software development, and human factors evaluated the DCS displays to document potential usability issues and propose design recommendations. The evaluation yielded 167 potential usability issues with the DCS. These issues should not be considered operator performance problems but rather opportunities identified by experts to improve upon the design of the DCS. A set of nine design recommendations was developed to address these potential issues. The design principles addressed the following areas: (1) color, (2) pop-up window structure, (3) navigation, (4) alarms, (5) process control diagram, (6) gestalt grouping, (7) typography, (8) terminology, and (9) data entry. Visuals illustrating the improved DCS displays accompany the design recommendations. These nine design principles serve as the starting point to a planned general DCS style guide that can be used across the U.S. nuclear industry to aid in the future design of effective DCS interfaces.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Experimental investigation of factors limiting slow axis beam quality in 9xx nm high power broad area diode lasers

GaAs-based broad-area diode lasers are needed with improved lateral beam parameter product (BPP{sub lat}) at high power. An experimental study of the factors limiting BPP{sub lat} is therefore presented, using extreme double-asymmetric (EDAS) vertical structures emitting at 910 nm. Continuous wave, pulsed and polarization-resolved measurements are presented and compared to thermal simulation. The importance of thermal and packaging-induced effects is determined by comparing junction -up and -down devices. Process factors are clarified by comparing diodes with and without index-guiding trenches. We show that in all cases studied, BPP{sub lat} is limited by a non-thermal BPP ground-level and a thermal BPP, which depends linearly on self-heating. Measurements as a function of pulse width confirm that self-heating rather than bias-level dominates. Diodes without trenches show low BPP ground-level, and a thermal BPP which depends strongly on mounting, due to changes in the temperature profile. The additional lateral guiding in diodes with trenches strongly increases the BPP ground-level, but optically isolates the stripe from the device edges, suppressing the influence of the thermal profile, leading to a BPP-slope that is low and independent of mounting. Trenches are also shown to initiate strain fields that cause parasitic TM-polarized emission with large BPP{sub lat}, whose influence on total BPP{sub lat} remains small, provided the overall polarization purity is >95%.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A General Method for Estimating Zonal Transmission Interface Limits from Nodal Network Data: Preprint

Capacity expansion models for the electric power system often employ zonal (rather than nodal) resolution, necessitating estimates of aggregate power transfer limits across the interfaces between model zones. Interface limits between planning areas are sometimes published, but they are not generalizable to arbitrary zone shapes. There is thus a need for a reproducible method for estimating interface transfer limits (ITLs) between user-defined zones directly from nodal transmission system data. Here, we present a simple method for estimating ITLs using a DC power flow approximation via the power transfer distribution factor (PTDF) matrix. Linear optimization is performed to identify the distribution of power flows that maximizes the total flow on interface-crossing lines, subject to individual line ratings, limits on bus injection/withdrawal, and the relationships among flows, injections, and withdrawals imposed by the PTDF matrix. We demonstrate the application of the method on a 134-zone ~65000-bus system, and we explore the influence of flow direction, contingency level, and zone size on the estimated ITLs. There is significant heterogeneity in the ratio of the ITL to the sum of interface-crossing line ratings, which highlights the importance of accounting for the physical constraints on power flows imposed by Kirchhoff's laws when estimating zonal ITLs.

17 WIND ENERGY↗