Search NASA⌕ Search

SEARCH · Search NASA

Results for “Performance Deviation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,009 records · Page 56

Development and performance analysis of a standard orifice flow calibration system

An orifice flow system has been developed indigenously which is a primary standard for the calibration of high vacuum gauges in the range of 10{sup -3}-10{sup -6} mbar. It consists of a constant-volume flow meter, designed to generate a known flow rate of a particular gas to the vacuum chamber. This chamber is partitioned into two parts by a plate with an orifice of calculable conductance. The pressures, generated by this standard system, are compared with those of secondary standard, namely, spinning rotor gauge. Different uncertainties and correction factors are calculated. The maximum percentage deviation is from 1.16% to 0.97%. The combined uncertainties over the entire calibration range of the standard system are in the range of 4.0x10{sup -6} mbar.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurements and searches for new physics in diboson processes with the D0 detector

This dissertation describes a comprehensive study of the Zγ → eeγ/μμγ/v$\bar{v}$γ process. The data have been collected with the DØ detector at the Fermilab Tevatron p¯p collider with the center-of-mass energy of 1.96 TeV, and correspond to up to 3.6 fb -1 of integrated luminosity. Firstly, in this study we perform a measurement of the Z production cross section. The measured cross sections in both ℓℓγ (ℓ= e or μ) and /v$\bar{v}$γ channels are the most precise cross sections measured at hadron colliders to date, and they agree within uncertainties with the theoretical calculations to the next-to-leading order. We claim the first observation of the Zγ → eeγ/μμγ/v$\bar{v}$γ process at hadron colliders at 5.1 standard deviations statistical significance. We also conduct a search for anomalous Zγ processes. Such anomalous Zγ processes, where a Z boson couples to a photon, result in an increased cross section and an enhancement of the production of high-energetic photons. Thus, an observation of this kind might possibly indicate the presence of new physics. Having found no excess of data over the SM expectations, we set the most restrictive 95% C.L. limits on the anomalous trilinear Z and ZZ gauge couplings (ATGC) at hadron colliders to date: |h$γ\atop{30}$| < 0.033, |h$γ\atop{40}$| < 0.0017, |h$Z\atop{30}$| < 0.033, and |h$Z\atop{40}$| < 0.0017, which mark almost three times improvement over the most recent results published to date. Three out of four current limits improve on the LEP limits, and are the tightest limits on ATGC in the world. Finally, we performed a search for narrow vector and scalar resonances that decay to Zγ . Many extensions of the SM predict such resonances, thus making this search a test of the gauge sector of the SM. We found no significant deviation of data from the SM predictions, and hence we set 95% C.L upper limits on the production cross section of the resonances.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

First Observation of C P Violation in B ¯ 0 → D C P ( * ) h 0 Decays by a Combined Time-Dependent Analysis of BABAR and Belle Data

We report a measurement of the time-dependent CP asymmetry of B¯ 0 → D$^{(*)}_{CP}$h 0 decays, where the light neutral hadron h 0 is a π 0 , η, or ω meson, and the neutral D meson is reconstructed in the CP eigenstates K + K – , K$^{0}_{S}$π 0 , or K$^{0}_{S}$ω. The measurement is performed combining the final data samples collected at the Υ(4S) resonance by the BABAR and Belle experiments at the asymmetric-energy B factories PEP-II at SLAC and KEKB at KEK, respectively. The data samples contain (471 ± 3) × 10 6 BB¯ pairs recorded by the BABAR detector and (772 ± 11) × 10 6 BB¯ pairs recorded by the Belle detector. We measure the CP asymmetry parameters –ηfS = +0.66 ± 0.10(stat) ± 0.06(syst) and C = –0.02 ± 0.07(stat) ± 0.03(syst). Here, these results correspond to the first observation of CP violation in B¯ 0 → D$^{(*)}_{CP}$h 0 decays. The hypothesis of no mixing-induced CP violation is excluded in these decays at the level of 5.4 standard deviations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Application of molecular convergent close-coupling cross sections in a collisional radiative model for the triplet system of molecular hydrogen

Collisional radiative (CR) models for molecular hydrogen are of high relevance for performing qualitative and quantitative analysis of excited-state population densities measured in plasmas or predicting the dependence of plasma emission on parameter variations. Although the development of such models for H 2 started decades ago, major uncertainties still exist regarding the most important set of input parameters, namely the cross sections for electron-impact excitation. The deviations between cross sections from different datasets are particularly pronounced in the energy region close to the threshold energy, strongly increasing the uncertainty of CR models applied to low-temperature plasmas. This paper presents experimental validation of a set of newly calculated non ro-vibrationally resolved electron-impact cross sections calculated for the triplet system of H 2 using the molecular convergent close-coupling method in the adiabatic-nuclei formulation. These cross sections are implemented into a CR model based on the flexible solver Yacora. A first comparison of CR calculations with the different datasets to experimentally-determined population densities is performed at a planar ICP discharge for varying pressure (between 1 and 10 Pa) and RF power (between 700 and 1100 W). For the experimentally-accessible electron temperature and density range (2.5–10 eV and 1.8–3.3 × 10 16 m –3 , respectively), very good agreement between the model and experiment is obtained using the new data set, in contrast to previously used cross sections.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Constraints on deviations from ΛCDM within Horndeski gravity

Recent anomalies found in cosmological datasets such as the low multipoles of the Cosmic Microwave Background or the low redshift amplitude and growth of clustering measured by e.g., abundance of galaxy clusters and redshift space distortions in galaxy surveys, have motivated explorations of models beyond standard ΛCDM. Of particular interest are models where general relativity (GR) is modified on large cosmological scales. Here we consider deviations from ΛCDM+GR within the context of Horndeski gravity, which is the most general theory of gravity with second derivatives in the equations of motion. We adopt a parametrization in which the four additional Horndeski functions of time α{sub i}(t) are proportional to the cosmological density of dark energy Ω{sub DE}(t). Constraints on this extended parameter space using a suite of state-of-the art cosmological observations are presented for the first time. Although the theory is able to accommodate the low multipoles of the Cosmic Microwave Background and the low amplitude of fluctuations from redshift space distortions, we find no significant tension with ΛCDM+GR when performing a global fit to recent cosmological data and thus there is no evidence against ΛCDM+GR from an analysis of the value of the Bayesian evidence ratio of the modified gravity models with respect to ΛCDM, despite introducing extra parameters. The posterior distribution of these extra parameters that we derive return strong constraints on any possible deviations from ΛCDM+GR in the context of Horndeski gravity. We illustrate how our results can be applied to a more general frameworks of modified gravity models.

79 ASTRONOMY AND ASTROPHYSICS↗

TU-F-CAMPUS-J-05: Fast Volumetric MRI On An MRI-Linac Enables On-Line QA On Dose Deposition in the Patient

Purpose: The introduction of the MRI-linac in radiotherapy brings MRI-guided treatment with daily plan adaptions within reach. This paradigm demands on-line QA. With its ability to perform continuous volumetric imaging in an outstanding soft-tissue contrast, the MRI- linac promises to elucidate the dose deposition process during a treatment session. Here we study for a prostate case how dynamic MRI combined with linac machine parameters and a fast dose-engine can be used for on-line dose accumulation. Methods: Prostate imaging was performed in healthy volunteer on a 1.5T MR-scanner (Philips, Best, NL) according to a clinical MR-sim protocol, followed by 10min of dynamic imaging (FLASH, 4s/volume, FOV 40×40×12cm{sup 3}, voxels 3×3×3mm{sup 3}, TR/TE/α=3.5ms/1.7ms/5°). An experienced radiation oncologist made delineations, considering the prostate CTV. Planning was performed on a two-compartment pseudoCT (air/water density) according to clinical constraints (77Gy in PTV) using a Monte-Carlo (MC) based TPS that accounts for magnetic fields. Delivery of one fraction (2.2Gy) was simulated on an emulator for the Axesse linac (Elekta, Stockholm, SE). Machine parameters (MLC settings, gantry angle, dose rate, etc.) were recorded at 25Hz. These were re-grouped per dynamic volume and fed into the MC-engine to calculate a dose delivered for each of the dynamics. Deformations derived from non-rigid registration of each dynamic against the first allowed dose accumulation on a common reference grid. Results: The DVH parameters on the PTV compared to the optimized plan showed little changes. Local deformations however resulted in local deviations, primarily around the air/rectum interface. This clearly indicates the potential of intra-fraction adaptations based on the accumulated dose. Application in each fraction helps to track the influence of plan adaptations to the eventual dose distribution. Calculation times were about twice the delivery time. Conclusion: The current Result paves the way to perform on-line treatment delivery QA on the MRI-linac in the near future.

60 APPLIED LIFE SCIENCES↗

Prediction of spout diameter in gas-solid spouted beds using factorial design of experiments approach with the aid of advanced optical fibre probe

In this study, the effects of five operating and design variables (solid density, static bed height, particle diameter, superficial gas velocity, and inlet diameter) on the average spout diameter of a 0.152 m inside diameter gas-solid spouted bed have been assessed experimentally using advanced gas-solid optical fibre probe technique. Statistical analysis of the experimental data including the factorial design of the experiments using MINITAB17 statistical software has been performed to determine the extent of the effects of these variables on the spout diameter as a case study. It was found that all five operating and design variables, except the solid density together with the 2-ways interactions between particles size and inlet diameter, in addition to gas velocity and inlet diameter, have a significant effect on the average spout diameter. Regression analysis was performed to correlate these variables with the average spout diameter for the gas-solid spouted beds. The obtained preliminary regression correlation was able to closely predict the average spout diameter of this work with the mean relative deviation value of 0.7 %.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Comparative studies of 2HDMs under the Higgs boson precision measurements

We perform comparative studies for four types of the two Higgs Doublet Models (2HDMs) under the precision measurements of the Standard Model (SM) Higgs observables at the proposed Higgs factories. We explore the discovery potential based on the hypothetical deviations in the precision data for the 2HDMs up to one-loop level. We find 5σ observability from the χ2 fitting in a significant theory parameter space at future Higgs factories. For the Type-I 2HDM, regions with cos(β - α) ≲ -0.1 or cos(β - α) ≳ 0.08 are discoverable at more than 5σ level. For the other three types of 2HDMs, the 5σ region is even bigger: | cos(β - α)| ≳ 0.02 for tan β ~ 1. At small and large values of tan β, the region in cos(β - α) is further tightened. We examine the extent to which the different 2HDM theories may be distinguishable from one to the other at the 95% Confidence Level with four benchmark points as case studies. We show that a large part of the parameter space of the other types of 2HDMs can be distinguished from the benchmark points of the target model. The impacts of loop corrections are found to be significant in certain parameter regions.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Sexual Functioning Among Endometrial Cancer Patients Treated With Adjuvant High-Dose-Rate Intra-Vaginal Radiation Therapy

Purpose: We used the Female Sexual Function Index (FSFI) to investigate the prevalence of sexual dysfunction (SD) and factors associated with diminished sexual functioning in early stage endometrial cancer (EC) patients treated with simple hysterectomy and adjuvant brachytherapy. Methods and Materials: A cohort of 104 patients followed in a radiation oncology clinic completed questionnaires to quantify current levels of sexual functioning. The time interval between hysterectomy and questionnaire completion ranged from <6 months to >5 years. Multivariate regression was performed using the FSFI as a continuous variable (score range, 1.2-35.4). SD was defined as an FSFI score of <26, based on the published validation study. Results: SD was reported by 81% of respondents. The mean ({+-} standard deviation) domain scores in order of highest-to-lowest functioning were: satisfaction, 2.9 ({+-}2.0); orgasm, 2.5 ({+-}2.4); desire, 2.4 ({+-}1.3); arousal, 2.2 ({+-}2.0); dryness, 2.1 ({+-}2.1); and pain, 1.9 ({+-}2.3). Compared to the index population in which the FSFI cut-score was validated (healthy women ages 18-74), all scores were low. Compared to published scores of a postmenopausal population, scores were not statistically different. Multivariate analysis isolated factors associated with lower FSFI scores, including having laparotomy as opposed to minimally invasive surgery (effect size, -7.1 points; 95% CI, -11.2 to -3.1; P<.001), lack of vaginal lubricant use (effect size, -4.4 points; 95% CI, -8.7 to -0.2, P=.040), and short time interval (<6 months) from hysterectomy to questionnaire completion (effect size, -4.6 points; 95% CI, -9.3-0.2; P=.059). Conclusions: The rate of SD, as defined by an FSFI score <26, was prevalent. The postmenopausal status of EC patients alone is a known risk factor for SD. Additional factors associated with poor sexual functioning following treatment for EC included receipt of laparotomy and lack of vaginal lubricant use.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Observation of photon-induced W+W- production in pp collisions at s = 13 TeV using the ATLAS detector

This letter reports the observation of photon-induced production of W -boson pairs, γγ → W W . The analysis uses 139 fb -1 of LHC proton–proton collision data taken at s = 13 TeV TeV recorded by the ATLAS experiment during the years 2015–2018. The measurement is performed selecting one electron and one muon, corresponding to the decay of the diboson system as W W → e ± νμ ∓ ν final state. The background-only hypothesis is rejected with a significance of well above 5 standard deviations consistent with the expectation from Monte Carlo simulation. A cross section for the γγ → W W process of 3.13 ± 0.31(stat.)±0.28(syst.) fb is measured in a fiducial volume close to the acceptance of the detector, by requiring an electron and a muon of opposite signs with large dilepton transverse momentum and exactly zero additional charged particles. This is found to be in agreement with the Standard Model prediction.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Observation of double parton scattering in same-sign W boson pair production in pp collisions at $\sqrt{s} = 13$ TeV with the ATLAS detector

This letter reports the measurement of double parton scattering in same-sign W boson pair production with the ATLAS detector. The data set used corresponds to an integrated luminosity of 140 fb -1 of proton–proton collisions at a center-of-mass energy of 13 TeV, collected during Run 2 of the Large Hadron Collider. The study is performed in final states including two same-charge leptons, electron or muon, missing transverse momentum, and up to one jet. An excess of events is observed over the expected background contributions with a significance of 8.8 standard deviations. The measured fiducial cross section times leptonic branching fraction is 4.59 ± 0.64 fb. The measurement corresponds to a double parton scattering effective cross section of 10.6 ± 1.8 mb.

DPS↗

Genome-driven evolutionary game theory helps understand the rise of metabolic interdependencies in microbial communities

Metabolite exchanges in microbial communities give rise to ecological interactions that govern ecosystem diversity and stability. It is unclear, however, how the rise of these interactions varies across metabolites and organisms. Here we address this question by integrating genome-scale models of metabolism with evolutionary game theory. Specifically, we use microbial fitness values estimated by metabolic models to infer evolutionarily stable interactions in multi-species microbial “games”. We first validate our approach using a well-characterized yeast cheater-cooperator system. We next perform over 80,000 in silico experiments to infer how metabolic interdependencies mediated by amino acid leakage in Escherichia coli vary across 189 amino acid pairs. While most pairs display shared patterns of inter-species interactions, multiple deviations are caused by pleiotropy and epistasis in metabolism. Moreover, simulated invasion experiments reveal possible paths to obligate cross-feeding. Our study provides genomically driven insight into the rise of ecological interactions, with implications for microbiome research and synthetic ecology.

59 BASIC BIOLOGICAL SCIENCES↗

Extended Fourier-transform spectroscopy studies and deperturbation analysis of the spin-orbit coupled A{sup 1}Σ{sup +} and b{sup 3}Π states in RbCs

The article presents a study of the strongly spin-orbit coupled singlet A{sup 1}Σ{sup +} and triplet b{sup 3}Π states of the RbCs molecule, which provide an efficient optical path to transfer ultracold molecules to their rovibrational ground state. Fourier-transform A{sup 1}Σ{sup +} − b{sup 3}Π → X{sup 1}Σ{sup +} and (4){sup 1}Σ{sup +} → A{sup 1}Σ{sup +} − b{sup 3}Π laser-induced fluorescence (LIF) spectra were recorded for the natural mixture of the {sup 85}Rb{sup 133}Cs and {sup 87}Rb{sup 133}Cs isotopologues produced in a heat pipe oven. Overall 8730 rovibronic term values of A{sup 1}Σ{sup +} and b{sup 3}Π states were determined with an uncertainty of 0.01 cm{sup −1} in the energy range [9012, 14087] cm{sup −1}, covering rotational quantum numbers J ∈ [6, 324]. An energy-based deperturbation analysis performed in the framework of the four A{sup 1}Σ{sup +} − b{sup 3}Π{sub Ω=0,1,2} coupled-channels approach reproduces 97% of the experimental term values of both isotopologues with a standard deviation of 0.0036 cm{sup −1}. The reliability of the deperturbed mass-invariant potentials and spin-orbit coupling functions of the interacting A{sup 1}Σ{sup +} and b{sup 3}Π states is additionally proved by a good reproduction of the A − b → X and (4){sup 1}Σ{sup +} → A − b relative intensity distributions. The achieved accuracy of the A − b complex description allowed us to use the latter to assign the observed (5){sup 1}Σ{sup +} → A − b and (3){sup 1}Π → A − b transitions. As is demonstrated, LIF to the A − b complex becomes as informative as to the ground X{sup 1}Σ{sup +} state, which is confirmed by comparing the results of (4){sup 1}Σ{sup +} state analysis based on (4){sup 1}Σ{sup +} → A − b LIF with the data from V. Zuters et al. [Phys. Rev. A 87, 022504 (2013)] based on (4){sup 1}Σ{sup +} → X LIF.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Formation of high quality interference fringes from both sides of a suitably designed hololens in the laser Doppler anemometer measurement volume

We report, for the first time to the best of our knowledge, the formation of high quality, evenly spaced, undistorted fringes in the measurement volume of a laser Doppler anemometer from both sides of a suitably designed hololens. Experiments are performed for the analysis of fringes formed at the measurement volume by real time monitoring and actual fringe field analysis techniques. The results indicate the qualitative as well as quantitative improvement of 66.58% in overall average normalised standard deviations of the width of the fringes formed by the proposed imaging configuration than that of the conventional imaging configuration. (laser applications and other topics in quantum electronics)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of the B s 0 → μ + μ - Branching Fraction and Effective Lifetime and Search for B 0 → μ + μ - Decays

A search for the rare decays $B^0_s$→$μ$ + $μ$ - and B 0 →$μ$ + $μ$ - is performed at the LHCb experiment using data collected in pp collisions corresponding to a total integrated luminosity of 4.4 fb -1 . An excess of $B^0_s$→$μ$ + $μ$ - decays is observed with a significance of 7.8 standard deviations, representing the first observation of this decay in a single experiment. The branching fraction is measured to be $B$($μ$ + $μ$ - )=(3.0 ± $0.6^{+0.3}_{-0.2}$) × 10 -9 , where the first uncertainty is statistical and the second systematic. The first measurement of the $B^0_s$→$μ$ + $μ$ - effective lifetime, τ($B^0_s$→($μ$ + $μ$ - ) = 2.04 ± 0.44 ± 0.05 ps, is reported. No significant excess of B 0 →($μ$ + $μ$ - decays is found, and a 95% confidence level upper limit, $B$(B 0 →($μ$ + $μ$ - ) < 3.4 × 10 -10 , is determined. All results are in agreement with the standard model expectations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

SU-E-J-217: Accuracy Comparison Between Surface and Volumetric Registrations for Patient Setup of Head and Neck Radiation Therapy

Purpose: Optical surface imaging has been applied to radiation therapy patient setup. This study aims to investigate the accuracy of the surface registration of the optical surface imaging compared with that of the conventional method of volumetric registration for patient setup in head and neck radiation therapy. Methods: Clinical datasets of planning CT and treatment Cone Beam CT (CBCT) were used to compare the surface and volumetric registrations in radiation therapy patient setup. The Iterative Closest Points based on point-plane closest method was implemented for surface registration. We employed 3D Slicer for rigid volumetric registration of planning CT and treatment CBCT. 6 parameters of registration results (3 rotations and 3 translations) were obtained by the two registration methods, and the results were compared. Digital simulation tests in ideal cases were also performed to validate each registration method. Results: Digital simulation tests showed that both of the registration methods were accurate and robust enough to compare the registration results. In experiments with the actual clinical data, the results showed considerable deviation between the surface and volumetric registrations. The average root mean squared translational error was 2.7 mm and the maximum translational error was 5.2 mm. Conclusion: The deviation between the surface and volumetric registrations was considerable. Special caution should be taken in using an optical surface imaging. To ensure the accuracy of optical surface imaging in radiation therapy patient setup, additional measures are required. This research was supported in part by the KIST institutional program (2E24551), the Industrial Strategic technology development program (10035495) funded by the Ministry of Trade, Industry and Energy (MOTIE, KOREA), and the Radiation Safety Research Programs (1305033) through the Nuclear Safety and Security Commission, and the NIH (R01EB016777)

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-F-J-25: Position Monitoring for Intracranial SRS Using BrainLAB ExacTrac Snap Verification

Purpose: To determine the accuracy of position monitoring with BrainLAB ExacTrac snap verification following couch rotations during intracranial SRS. Methods: A CT scan of an anthropomorphic head phantom was acquired using 1.25mm slices. The isocenter was positioned near the centroid of the frontal lobe. The head phantom was initially aligned on the treatment couch using cone-beam CT, then repositioned using ExacTrac x-ray verification with residual errors less than 0.2mm and 0.2°. Snap verification was performed over the full range of couch angles in 15° increments with known positioning offsets of 0–3mm applied to the phantom along each axis. At each couch angle, the smallest tolerance was determined for which no positioning deviation was detected. Results: For couch angles 30°–60° from the center position, where the longitudinal axis of the phantom is approximately aligned with the beam axis of one x-ray tube, snap verification consistently detected positioning errors exceeding the maximum 8mm tolerance. Defining localization error as the difference between the known offset and the minimum tolerance for which no deviation was detected, the RMS error is mostly less than 1mm outside of couch angles 30°–60° from the central couch position. Given separate measurements of patient position from the two imagers, whether to proceed with treatment can be determined by the criterion of a reading within tolerance from just one (OR criterion) or both (AND criterion) imagers. Using a positioning tolerance of 1.5mm, snap verification has sensitivity and specificity of 94% and 75%, respectively, with the AND criterion, and 67% and 93%, respectively, with the OR criterion. If readings exceeding maximum tolerance are excluded, the sensitivity and specificity are 88% and 86%, respectively, with the AND criterion. Conclusion: With a positioning tolerance of 1.5mm, ExacTrac snap verification can be used during intracranial SRS with sensitivity and specificity between 85% and 90%.

60 APPLIED LIFE SCIENCES↗

A study of muon neutrino disappearance with the MINOS detectors and the NuMI neutrino beam

This thesis presents the results of an analysis of v μ disappearance with the MINOS experiment, which studies the neutrino beam produced by the NuMI facility at Fermi National Accelerator Laboratory. The rates and energy spectra of charged current v μ interactions are measured in two similar detectors, located at distances of 1 km and 735 km along the NuMI beamline. The Near Detector provides accurate measurements of the initial beam composition and energy, while the Far Detector is sensitive to the effects of neutrino oscillations. The analysis uses data collected between May 2005 and March 2007, corresponding to an exposure of 2.5 x 10 20 protons on target. As part of the analysis, sophisticated software was developed to identify muon tracks in the detectors and to reconstruct muon kinematics. Events with reconstructed tracks were then analyzed using a multivariate technique to efficiently isolate a pure sample of charged current v μ events. An extrapolation method was also developed, which produces accurate predictions of the Far Detector neutrino energy spectrum, based on data collected at the Near Detector. Finally, several techniques to improve the sensitivity of an oscillation measurement were implemented, and a full study of the systematic uncertainties was performed. Extrapolating from observations at the Near Detector, 733 ± 29 Far Detector events were expected in the absence of oscillations, but only 563 events were observed. This deficit in event rate corresponds to a significance of 4.3 standard deviations. The deficit is energy dependent and clear distortion of the Far Detector energy spectrum is observed. A maximum likelihood analysis, which fully accounts for systematic uncertainties, is used to determine the allowed regions for the oscillation parameters and identifies the best fit values as Δm$2\atop{32}$ = 2.29$+0.14\atop{-0.14}$ x 10 -3 eV 2 and sin 2 2θ 23 > 0.953 (68% confidence level). The models of neutrino decoherence and decay are disfavored at the 5.0σ and 3.2σ levels respectively, while the no oscillation model is excluded at the 9.4σ level.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗