Search NASA⌕ Search

SEARCH · Search NASA

Results for “Performance Rating Method”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,009 records · Page 56

Estimation of the Water Table Position in Unconfined Aquifers with MODFLOW 6

Abstract The numerical estimation of the position of the water table in unconfined aquifers is important for many practical applications. Its determination through observations or analytical methods is restricted to a few cases. Therefore, it is often estimated through numerical simulations, which may be affected by numerical artifacts and/or poor stability. We use MODFLOW to estimate the position of the water table for a seemingly simple example problem and demonstrate difficulties that can be faced when performing this kind of numerical simulation. We explain the causes for the numerical challenges that originate from the properties of the mathematical equations that must be solved. Based on the results of more than 600 steady‐state simulations, we show how the stability of the numerical solution can be affected by the values of physical parameters that define the problem (e.g., recharge rate, anisotropy ratio, and other parameters that control the numerical algorithm such as settings of the linear and nonlinear solution methods). Finally, we comment on some best practices to apply numerical simulations to estimate the water table position.

Geology↗

X-Ray Spectra from General Relativistic Radiation Magnetohydrodynamic Simulations of Thin Disks

We compare X-ray emission from several general relativistic, multifrequency, radiation magnetohydrodynamic simulations of thin black hole accretion disks with different accretion rates and spins. The simulations were performed using the M1 closure scheme, resolved with 12 frequency (energy) bins logarithmically spaced from 5 × 10 −3 to 5 × 10 3 ​​​ keV. We apply a general relativistic Monte Carlo transport code to postprocess the simulation data with greater fidelity in frequency resolution and Compton scattering treatment. Despite the relatively few energy bins and Kompaneets approximation to Compton scattering utilized in the M1 method, we find generally good agreement between the methods. Both produce prominent thermal profiles with peaks around 2–2.5 keV, where agreement is particularly strong and representative of the soft state. Both also find weaker (lower-luminosity) thermally sourced emission extending out to 100 keV due to the hotter innermost regions of the disks. Inverse Compton scattering becomes increasingly effective at hardening spectral outputs with increasing black hole spin, and becomes the dominant mechanism for photons that escape with energies between 10 to several hundred keV. At very high rates of spin, the radiation flux in this upscattered component becomes comparable to the thermal flux, a phenomenon typically associated with intermediate states. Beyond 10 4 keV, we observe faint, free–free emission from hot, optically thin coronal regions developing near the horizon, common to both spinning and nonspinning black holes.

79 ASTRONOMY AND ASTROPHYSICS↗

Strategy of Using Intratreatment Hypoxia Imaging to Selectively and Safely Guide Radiation Dose De-escalation Concurrent With Chemotherapy for Locoregionally Advanced Human Papillomavirus–Related Oropharyngeal Carcinoma

Purpose: To report a small substudy of an ongoing large, multi-arm study using functional imaging to assess pre-/intratreatment hypoxia for all head and neck cancer, in which we hypothesized that pre- and early-treatment hypoxia assessment using functional positron emission tomography (PET) imaging may help select which human papillomavirus (HPV)-positive (HPV{sup +}) oropharyngeal cancer (OPC) patients can safely receive radiation de-escalation without jeopardizing treatment outcomes. Methods and Materials: Patients with HPV{sup +} oropharyngeal carcinoma were enrolled on an institutional review board–approved prospective study of which de-escalation based on imaging response was done for node(s) only. Pretreatment {sup 18}F-fluorodeoxyglucose and dynamic {sup 18}F-FMISO (fluoromisonidazole) positron emission tomography (PET) scans were performed. For patients with pretreatment hypoxia on{sup 18}F-FMISO PET (defined as a >1.2 tumor to muscle standard uptake value ratio), a repeat scan was done 1 week after chemoradiation. Patients without pretreatment hypoxia or with resolution of hypoxia on repeat scan received a 10-Gy dose reduction to metastatic lymph node(s). The 2-year local, regional, distant metastasis–free, and overall survival rates were estimated using the Kaplan-Meier product-limit method. A subset of patients had biopsy of a hypoxic node done under image guidance. Results: Thirty-three HPV{sup +} OPC patients were enrolled in this pilot study. One hundred percent showed pretreatment hypoxia (at primary site and/or node[s]), and among these, 48% resolved (at primary site and/or node[s]); 30% met criteria and received 10-Gy reduction to the lymph node(s). At the median follow-up of 32 months (range, 21-61 months), the 2-year locoregional control rate was 100%. One patient failed distantly with persistence of hypoxia on {sup 18}F-FMISO PET. The 2-year distant metastasis–free rate was 97%. The 2-year OS rate was 100%. Hypoxia on imaging was confirmed pathologically. Conclusions: Hypoxia is present in HPV{sup +} tumors but resolves within 1 week of treatment in 48% of cases either at the primary site and/or lymph node(s). Our 100% locoregional control rate suggests that intratreatment functional imaging used to selectively de-escalate node(s) to 60 Gy was confirmed safe using our stringent imaging criteria. Intratreatment functional imaging warrants further study to determine its ultimate role in de-escalation treatment strategies.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

An investigation of a novel reusable radiochromic sheet for 2D dose measurement

Purpose Radiochromic film remains a useful and versatile clinical dosimetry tool. Current film options are single use. Here, we introduce a novel prototype two‐dimensional (2D) radiochromic sheet, which optically clears naturally at room temperature after irradiation and can be reused. We evaluate the sheets for potential as a 2D dosimeter and as a radiochromic bolus with capability for dose measurement. Methods A novel derivative of reusable Presage ® was manufactured into thin sheets of 5 mm thickness. The sheets contained 2% cumin‐leucomalachitegreen‐diethylamine (LMG‐DEA) and plasticizer (up to 25% by weight). Irradiation experiments were performed to characterize the response to megavoltage radiation, including dose sensitivity, temporal decay rate, consistency of repeat irradiations, intra and inter‐sheet reproducibility, multi‐modality response (electrons and photons), and temperature sensitivity (22°C to 36°C). The local change in optical‐density (ΔOD), before and after radiation, was obtained with a flat‐bed film scanner and extracting the red channel. Repeat scanning enabled investigation of the temporal decay of ΔOD. Additional studies investigated clinical utility of the sheets through application to IMRT treatment plans (prostate and a TG119 commissioning plan), and a chest wall electron boost treatment. In the latter test, the sheet performed as a radiochromic bolus. Results The radiation induced OD change in the sheets was found to be proportional to dose and to exponentially decay to baseline in ~24 h (R2 = 0.9986). The sheet could be reused and had similar sensitivity (within 1% after the first irradiation) for at least eight irradiations. Importantly, no memory of previous irradiations was observed within measurement uncertainty. The consistency of dose response from photons (6 and 15 MV) and electrons (6–20 MeV) was found to be within calibration uncertainty (~1%). The dose sensitivity of the sheets had a temperature dependence of 0.0012 ΔOD/°C. For the short (1 min) single field IMRT QA verification, good agreement was observed between the Presage sheet and EBT film (gamma pass rate 97% at 3% 3 mm dose‐difference and distance‐to‐agreement tolerance, with a 10% threshold). For the longer (~13 min) TG‐119 9‐field IMRT verification the gamma agreement was lower at 93% pass rate at 5% 3 mm, 10% threshold, when compared with Eclipse. The lower rate is attributed to uncertainty arising from signal decay during irradiation and indicates a current limitation. For the electron cutout treatment, both Presage and EBT agreed well (within 2% RMS difference) but differed from the Eclipse treatment plan (~7% RMS difference) indicating some limitations to the Eclipse modeling in this case. The worst case estimates of uncertainty introduced by the signal decay for deliveries of 2, 5, and 10 min are 0.6%, 1.4%, and 2.8% respectively. Conclusions Reusable Presage sheets show promise for 2D dose measurement and as a radiochromic bolus for in vivo dose measurement. The current prototype is suitable for deliveries of length up to 5 min, where the uncertainty introduced by signal decay is anticipated to be ~1% (worst case 1.4%), or for longer deliveries where there is no temporal modulation (e.g. physical compensators, or open beams). Additionally, spatial resolution is limited by sheet thickness and scanner resolution, resulting in a practical resolution of 0.8 mm.

Collins, Cielle↗

Automated detection of photovoltaic cleaning events: A performance comparison of techniques as applied to a broad set of labeled photovoltaic data sets

Extracting accurate soiling loss information from photovoltaic (PV) production data first requires segmenting the time series data per natural or manually occurring cleaning events. Maintenance logs are often incomplete, rain data are often unavailable, and the debate on rain thresholds for cleaning and dew or wind cleanings is still ongoing. The present work aims to overtake these issues by improving automated methods to detect these cleaning events and therefore improve extraction of soiling loss information. Time series power production data from 22 PV inverters were labeled for natural or manually occurring cleaning events. The data sets were carefully selected to include varying degrees of soiling, cleaning events, and noise. Several algorithms, including filtering logic and change point detection, were examined for efficacy at detecting the labeled cleanings. All the methods introduced except for changepoint detection showed significant improvement at detecting the labeled cleaning events per the mean F 1 score. Furthermore, the highest performing cleaning detection algorithm achieved an absolute increase in the mean F 1 score of 43% over the default version of the RdTools stochastic rate and recovery (SRR) algorithm. The highest performing algorithm included irradiance filtering and a cleaning detection threshold, adjusted based on the 40-day centered rolling median of the absolute day-to-day deviations in the daily performance index (PI). Furthermore, these improvements are promising as cleaning detection is an essential step in the automated analysis of PV soiling.

14 SOLAR ENERGY↗

Fast Multilevel Solvers for a Class of Discrete Fourth Order Parabolic Problems

In this paper, we study fast iterative solvers for the solution of fourth order parabolic equations discretized by mixed finite element methods. We propose to use consistent mass matrix in the discretization and use lumped mass matrix to construct efficient preconditioners. We provide eigenvalue analysis for the preconditioned system and estimate the convergence rate of the preconditioned GMRes method. Furthermore, we show that these preconditioners only need to be solved inexactly by optimal multigrid algorithms. Our numerical examples indicate that the proposed preconditioners are very efficient and robust with respect to both discretization parameters and diffusion coefficients. We also investigate the performance of multigrid algorithms with either collective smoothers or distributive smoothers when solving the preconditioner systems.

97 MATHEMATICS AND COMPUTING↗

Improving Corrosion Resistance and Corrosive Wear Resistance of Aluminum Alloy Drill Pipe by Surface Nanocrystallization and Micro-arc Oxidation

To improve the corrosion and wear resistance performance of aluminum alloy drill pipes in geological and petroleum drilling applications, a strengthening coating was prepared on the surface of the 2618 aluminum alloy by combining treatment with ultrasonic cold forging technology (UCFT) and micro-arc oxidation (MAO). The effects of the strengthening coating on the corrosion and wear resistance of the aluminum alloy were evaluated by electrochemical and tribological tests. The results demonstrated that the corrosion and wear resistance of the aluminum alloy were improved by the UCFT and MAO technologies, especially the salt corrosion resistance. The corrosion morphology of the strengthening coating primarily included pitting, micro-cracks and NaCl attachment. In addition, the UCFT + MAO composite coating exhibited the best wear performance. The wear rate of the UCFT + MAO composite coating was lower than that of the aluminum alloy by 94%. The results provided support for this excellent surface treatment technology for the corrosion and wear resistance of aluminum alloy drill pipes, and they also present a feasible evaluation method for drill pipes.

36 MATERIALS SCIENCE↗

Development and validation of an automatic method to detect the latest contracting viable left ventricular segments to assist guide CRT therapy from gated SPECT myocardial perfusion imaging

Objectives: The purpose of this study is to use ECG-gated SPECT MPI to detect the latest contracting viable left ventricular (LV) segments to help guide the LV probe placement used in CRT therapy and to validate segment selection against the visual integration method by experts. Methods: For each patient, the resting ECG-gated SPECT MPI short-axis images were sampled in 3D to generate a polar map of the perfusion distribution used to determine LV myocardial viability, and to measure LV synchronicity using our phase analysis tool. In the visual integration method, two experts visually interpreted the LV viability and mechanical dyssynchrony from the short-axis images and polar maps of viability and phase, to determine the latest contracting viable segments using the 17-segment model. In the automatic method, the apical segments, septal segments, and segments with more than 50% scar were excluded as these are not candidates for CRT LV probe placement. Amongst the remaining viable segments, the segments, whose phase angles were within 10° of the latest phase angle (the most delayed contracting segment), were identified for potential CRT LV probe placement and ranked based on the phase angles of the segments. Both methods were tested in 36 pre-CRT patients who underwent ECG-gated SPECT MPI. The accuracy was determined as the percent agreement between the visual integration and automatic methods. The automatic method was performed by a second independent operator to evaluate the inter-operator processing reproducibility. Results: In all the 36 patients, the LV lead positions of the 1st choices recommended by the automatic and visual integration methods were in the same segments in 35 patients, which achieved an agreement rate of 97.2%. In the inter-operator reproducibility test, the LV lead positions of the 1st choices recommended by the two operators were in the same segments in 25 patients, and were in the adjacent segments in 7 patients, which achieved an overall agreement of 88.8%. Conclusions: An automatic method has been developed to detect the latest contracting viable LV segments to help guide the LV probe placement used in CRT therapy. The retrospective clinical study with 36 patients suggests that this method has high agreement against the visual integration method by experts and good inter-operator reproducibility. Consequently, this method is promising to be a clinical tool to recommend the CRT LV lead positions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Towards high data-rate diffusive molecular communications: A review on performance enhancement strategies

Diffusive molecular communications (DiMC) have recently gained attention as a candidate for nano- to micro- and macro-scale communications due to its simplicity and energy efficiency. As signal propagation is solely enabled by Brownian motion mechanics, DiMC faces severe inter-symbol interference (ISI), which limits reliable and high data-rate communications. Herein, recent literature on DiMC performance enhancement strategies is surveyed; key research directions are identified. Signaling design and associated design constraints are presented. Here, studies on fundamental information theoretic limits of DiMC channel are reviewed. Classical and novel transceiver designs are discussed with an emphasis on methods for ISI mitigation and performance-complexity tradeoffs. Key parameter estimation strategies such as synchronization and channel estimation are considered in conjunction with asynchronous and timing error robust receiver methods. Finally, source and channel coding in the context of DiMC is presented.

42 ENGINEERING↗

Multi-material additive manufacturing of aluminum 6061-T6 alloy with stainless steel 304: Suppression of intermetallic compounds and interface growth mechanism

Fabricating integrated aluminum-steel structures is difficult because of metallurgical incompatibilities that promote intermetallic compound (IMC) formation at their interfaces. This work introduces a practical route for additively manufacturing 6061-T6 aluminum alloy (AA6061-T6) directly onto 304 stainless steel (SS304) using a high shear strain rate-assisted interfacial bonding mechanism. Through the friction extrusion deposition-based additive manufacturing method, both single- and multi-layer deposits of AA6061-T6 were successfully fabricated on SS304, yielding a robust hybrid multi-material structure. Comprehensive analyses of deposition quality, interface porosity, and bonding performance showed that the interface achieved a tensile strength exceeding 154 MPa under quasi-static loading. Microstructural observations revealed that the deposited aluminum layers experienced severe plastic deformation, resulting in pronounced grain refinement. Importantly, the interfacial zone was found to be free of brittle IMCs, instead containing a thin amorphous layer that evolved through a non-linear reaction-zone growth law. This solid-state additive strategy establishes a promising pathway for lightweight structural systems, nuclear energy component cladding, and multifunctional engineering components, redefining how dissimilar metals can be integrated for advanced applications.

Aluminum alloy↗

Facile synthesis of various α-Fe2O3 micro/nanostructures: Highlighting on the enhanced catalysis activities by formation of bowl-like α-Fe2O3/Au composites

Highlights: • Various α-Fe{sub 2}O{sub 3} micro/nanostructures are fabricated by a hydrothermal method. • The morphologies are tunable by changing the content of NaHCO{sub 3} and reaction time. • Bowl-like α-Fe{sub 2}O{sub 3} has the highest Fenton catalytic efficiency in dark condition. • Fast photo-Fenton reaction of α-Fe{sub 2}O{sub 3}/Au can be tuned by multiphase structures. • Bowl-like α-Fe{sub 2}O{sub 3}/Au is an excellent photo-Fenton catalyst for water treatment. - Abstract: Various α-Fe{sub 2}O{sub 3} micro/nanostructures referring to spherical-like, bowl-like, cubic, and discoid shapes have been fabricated by a facile hydrothermal method using sodium bicarbonate as surfactant and alkaline reagents, displaying superior Fenton catalytic performances for degradation of Rhodamine 6G. Because of abundant exposed crystal surfaces such as (110) and (104) on the surfaces of bowl-like α-Fe{sub 2}O{sub 3}, the rapid degradation rate of 90.0% in 5 min is observed under the dark condition as the adding amount of H{sub 2}O{sub 2} limiting to 300 μL. Significantly, the enhanced catalytic performances of bowl-like α-Fe{sub 2}O{sub 3}/Au catalysts under natural light condition have been investigated and carried out by in situ reduction of well-distributed Au nanoparticles with average sizes of 3–6 nm. Due to the appropriate phase structures and heterogenous interface properties, the highest photo-Fenton catalytic activity with the degradation rate of 90.0% in 2 min can be obtained for α-Fe{sub 2}O{sub 3}/Au{sub 0.01} composites.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Spin-on deposition of amorphous zeolitic imidazolate framework films for lithography applications

Amorphous zeolitic imidazolate framework (aZIF) films have been recently introduced as resists for electron beam and extreme ultraviolet lithography. aZIFs are also being considered for separation applications, including thin film membranes. However, the reported methods for aZIF deposition are currently based on highly empirical trial-and-error approaches that hinder control of film composition, thickness and uniformity as well as scale-up and transferability to different coating geometries. This work presents a method for depositing aZIF films with controllable thickness using dilute precursors mixed immediately before encountering the substrate. Importantly, the method is amenable to quantitative analysis by computational fluid dynamics to extract intrinsic deposition rates and limiting reactant transport diffusivities, enabling predictive physics-based modeling of the deposition process. This allows the deposition method to be adapted for spin coating on silicon wafers to prepare high-quality aZIF films with consistently controlled thickness. Using this approach, high-resolution resist performance and wafer-scale use for beyond extreme-ultraviolet lithography of aZIF films is demonstrated.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Ion-temperature-gradient stability near the magnetic axis of quasisymmetric stellarators

Abstract The stability of the ion-temperature gradient mode in quasisymmetric stellarators is assessed. This is performed using a set of analytical estimates together with linear gyrokinetic simulations. The peak growth rates, their corresponding real frequencies and wave-vectors are identified. A comparison is made between a first-order near-axis expansion model and eleven realistic designs obtained using numerical optimization methods. It is found that while the near-axis expansion is able to replicate the growth rates, real frequencies and perpendicular wave-vector at the inner core (both using simplified dispersion relations and first-principle gyrokinetic simulations), it leads to an overestimation of the growth rate at larger radii. An approximate analytic solution of the ITG dispersion relation for the non-resonant limit suggests growth rates could be systematically higher in quasi-axisymmetric (QA) configurations compared to quasi-helically (QH) symmetric ones. However except for very close to the axis, linear gyrokinetic simulations do not show systematic differences between QA and QH configurations.

Physics↗

Angular analysis of B → K * e + e − in the low- q 2 region with new electron identification at Belle

We perform an angular analysis of the B → K * e + e − decay for the dielectron mass squared, q 2 , range of 0.0008 – 1.1200 GeV 2 / c 4 using the full Belle dataset in the K * 0 → K + π − and K * + → K S 0 π + channels, incorporating new methods of electron identification to improve the statistical power of the dataset. This analysis is sensitive to contributions from right-handed currents from physics beyond the Standard Model by constraining the Wilson coefficients C 7 ( ′ ) . We perform a fit to the B → K * e + e − differential decay rate and measure the imaginary component of the transversality amplitude to be A T Im = − 1.27 ± 0.52 ± 0.12 , and the K * transverse asymmetry to be A T ( 2 ) = 0.52 ± 0.53 ± 0.11 , with F L and A T Re fixed to the Standard Model values. The resulting constraints on the value of C 7 ′ are consistent with the Standard Model within a 2 σ confidence interval. Published by the American Physical Society 2024

Ferlewicz, D. (ORCID:0000000243741234)↗

Accurate Efficiency Measurements for Emerging PV: A Comparison of NREL's Steady-State Performance Calibration Protocol Between Conventional and Emerging PV Technologies

Emerging PV technologies (e.g. Perovskite, and Quantum Dot) are commonly known to possess challenges for accurate performance measurement under the existing IEC 60904 series of standards, which were developed for conventional Si solar cells. Potential performance artifacts depending on scan rates and directions and light bias exposure history are often seen in those emerging solar cells. To avoid these artifacts and provide an unbiased and reliable efficiency measurement, NREL's Cell and Module Performance (CMP) Group has developed a steady-state performance calibration protocol - the asymptotic P MAX method. In this paper, we applied this procedure to four PV cell technologies, Si, CIGS, perovskite, and Quantum Dot (QD), and compared their performance variations between the transient and the steady-state conditions. By comparison, we found that the performance parameters ( i.e. V OC , I SC , FF, ..eta..) measured between fast I-V scans (and the asymptotic method (steady-state) change significantly for perovskite and QD cells. These changes do not happen for Si and CIGS cells. Furthermore, the statistical performance analysis on nearly 100 emerging cells received globally (including OPV, Perovskite, and QD) shows that over 70 % of the fast I-V scans have a relative performance deviation larger than 1% compared to those determined using the asymptotic P MAX scan. Given the complex dynamic behavior observed in emerging PV devices, the CMP group at NREL thus only certifies their steady steady-state performance using the Asymptotic P MAX method. We highly recommend similar steady-state performance calibration protocol for all researchers in emerging PV because accuracy in reported efficiencies is critical to the long-term success of those promising new PV technologies.

41 EE - Solar Energy Technologies Office (EE-4S)↗

SU-F-T-313: Clinical Results of a New Customer Acceptance Test for Elekta VMAT

Purpose: To report the results of a customer acceptance test (CAT) for VMAT treatments for two matched Elekta linear accelerators. Methods: The CAT tests were performed on two clinically matched Elekta linear accelerators equipped with a 160-leaf MLC. Functional tests included performance checks of the control system during dynamic movements of the diaphragms, MLC, and gantry. Dosimetric tests included MLC picket fence tests at static and variable dose rates and a diaphragm alignment test, all performed using the on-board EPID. Additionally, beam symmetry during arc delivery was measured at the four cardinal angles for high and low dose rate modes using a 2D detector array. Results of the dosimetric tests were analyzed using the VMAT CAT analysis tool. Results: Linear accelerator 1 (LN1) met all stated CAT tolerances. Linear accelerator 2 (LN2) passed the geometric, beam symmetry, and MLC position error tests but failed the relative dose average test for the diaphragm abutment and all three picket fence fields. Though peak doses in the abutment regions were consistent, the average dose was below the stated tolerance corresponding to a leaf junction that was too narrow. Despite this, no significant differences in patient specific VMAT quality assurance measured were observed between the accelerators and both passed monthly MLC quality assurance performed with the Hancock test. Conclusion: Results from the CAT showed LN2 with relative dose averages in the abutment regions of the diaphragm and MLC tests outside the tolerances resulting from differences in leaf gap distances. Tolerances of the dose average tests from the CAT may be small enough to detect MLC errors which do not significantly affect patient QA or the routine MLC tests.

60 APPLIED LIFE SCIENCES↗

A New Appraisal- Lessons from the History of Efforts to Value Green and High-Performance Home Attributes in the United States

Rigorous consideration of green and high-performance (“green/HP”) features is rarely included in the property valuation process._ To help illuminate why this is the case, this report takes stock of the history of efforts to improve practices, and identifies barriers that have emerged and opportunities for overcoming them. Particular emphasis is placed on what energy and environmental policymakers and other stakeholders outside the appraisal community can contribute to the broader effort to advance professional practices. The history has unfolded in parallel with turbulent periods in the housing market for which appraisers and their customers are deemed to share responsibility, followed by cycles of regulations, siloing of appraisers in the name of professional integrity, and commoditization of the valuation process itself. This pattern has important ramifications for aspirations that appraisers engage more fully in identifying and valuing the green/HP characteristics of homes. On the one hand, it is legally and ethically incumbent on appraisers to do so, yet on the other hand it is perceived as a risky avenue to follow. Risks arise where findings can be challenged as either over- or under-stating value, together with a market environment in which the complexity of their assignments increases despite downward pressure on appraiser fees. While efforts to address green/HP considerations date back to the early 1980s, the vast majority of activity has taken place within the past five years. Many players have engaged in the efforts to promote improved valuation practices. These include the Appraisal Foundation, The Appraisal Institute, Colorado Energy Office, Earth Advantage, EcoBroker, Elevate Energy, Fannie Mae, Federal Housing Administration, Home Innovation Research Labs, The Institute for Market Transformation, Northwest Energy Efficiency Alliance, National Association of Homebuilders, National Association of State Energy Officials, National Association of Appraisers, RESNET, USEPA, USDOE and its National Laboratories, the U.S. Green Buildings Council, and the Vermont Green Homes Alliance. Many activities have resulted, ranging from trainings, to data-gathering instruments, and the emergence of a literature attempting to statistically isolate the effects of green/HP characteristics on home values. In some cases, the results of studies have been overgeneralized and oversold, and embodied flawed methods. Although the green/HP community has encouraged appraisers to focus on exemplary buildings (e.g., LEED or ENERGY STAR Certified), any level of green or energy performance can in fact influence value, including below-average performance (a.k.a. “brown discount”), irrespective of whether or not the building has been formally rated. This overly narrow focus represents a significant missed opportunity. Other surmountable challenges include limitations to non-appraisers’ understanding of the appraisal process (and practical constraints therein). A byproduct of this can be unrealistic expectations of what appraisers can and will do in the marketplace. These challenges notwithstanding, the environment for moving forward has improved. There is better data today (a critical need); expanded efforts to disclose energy use information (characteristics, consumption, bills); improved and more pervasive building energy codes, building rating and labeling initiatives; and a host of federal, state, and local policies that have collectively brought green/HP practices much more into the mainstream. Meanwhile, a renewed focus on professional standards of care and competency for assessing green/HP homes make it increasingly important for appraisers to consider these factors in their assignments. Despite the past four decades of studies, there is little if any discernible uptake of these practices by the appraisal practice at large. It would behoove interested parties to step back and consider what new strategies might be productive. A key element of any new plan should be to reset the nature of interactions with the industry, with the goal a more collaborative, two-way discussion to help improve outsiders’ understanding of the valuation process. It is not only the appraiser that needs to be engaged and could benefit from awareness raising. Homeowners, builders, lenders, utilities, insurance companies should also provide input on how green/HP factors impact property valuations and ways to accurately reflect these considerations in appraisals and real estate transactions more broadly. Given extensive inertia within the appraisal industry and a mixed history of interactions with the non-appraisal stakeholders, it is unlikely that the status quo will achieve much unless followed with more coordinated and persistent efforts. Workshops, studies, and memoranda of understanding will not on their own have much impact, and do not address deeper structural issues. Expectations are often unrealistic and not attentive to real-world constraints faced by appraisers. The report identifies key barriers impeding more thorough consideration of green/HP factors in residential real estate appraisals, and solutions for mitigating them. Barriers • Although industry standards of practice caution against bias of any sort, a skeptical predisposition towards “green” is reinforced by information deficiencies. • Information deficiencies result from the lack or difficulty of obtaining usable data on green/HP features in subject properties as well as valid sales comparisons or cashflow analyses. • Competency deficiencies, such as lack of conversancy in relevant technical topics, leads to oversights, and disjointed treatment of relevant information. • Time/cost pressure and process commoditization (e.g., template-based approaches) result from highly constrained budgets, quick turn-around times expected of appraisers, and standardized practices that were not developed with green/HP considerations in mind. • Professional differences between appraisers and sustainability professionals include divergent objectives, the former being market observers and the latter market influencers. • Risk aversion arises from multiple concerns including veracity, accuracy, and persistence of energy data, impacts of operational choices, new sources of appraiser liability associated with green/HP assessments, industry pressures not to over-value buildings or suggestion of bias, and concern about spending non-billable time on complex assignments. • A public policy vacuum has been created by disjointed and uncoordinated efforts from public-sector stakeholders, insufficient efforts to discuss and understand the appraisal industry and process, and a perception by some valuation professionals that green/HP is oversold. Opportunities • Elevating the competency of appraisers can be achieved through a combination of improved industry standards of care and equal-access training and professional development offerings. • Development of better information resources must focus on building-level information that provides robust documentation as well as aggregate sales-comparison data and other contextual information such as local codes, typical upgrade costs, energy prices, etc. • Improved energy benchmarking and rating tools could provide appraisers with information more well-adapted to their particular needs, which differ from those of typical audiences such as energy managers. • Better characterizing and managing risk will enable appraisers to cope with uncertainties in performance information, and help identify where risks may be introduced or mitigated by green/HP features, including higher costs or obsolescence of poorly-performing buildings. • Integrating disaster resilience and sustainability in appraisals would recognize important synergisms among these features, including durability and ability of green/HP buildings to better withstand external hazards. • Mitigating the problem of additional time/cost for performing assignments is an essential need that can be addressed by providing easier access to information and analytic procedures, perhaps coupled with new resources to defray the associated costs. • Enhancing demand for improved appraisals is a fundamental need, and depends on owners, developers, lenders, and others soliciting competent appraisers to perform scopes that expressly call out green/HP considerations, and to critically review the work product for compliance before acceptance. • Engaging new market participants, such as energy utilities and insurance companies can ensure fuller representation and participation of market stakeholders already engaged in green/HP activities and capable of furnishing valuable data and managing associated risks. Cutting across these individual activities, there is a need for outside stakeholders to formulate and follow a roadmap instead of piecemeal initiatives, bridging the professional/cultural divide between appraisers and green/HP communities, and tracking progress in order to know what is working. A more coherent communication and training strategy is needed, as the appraisal industry is highly fragmented, with two-thirds of appraisers opting out of membership in trade associations. In sum, while there is no silver bullet for advancing the practice of valuing green/HP features, there are concrete opportunities. Parties seeking solutions must identify barriers they wish to address and select from among potential initiatives that map to those barriers. Close collaboration with the appraisal community is critical, as non-appraisers have historically obtained limited traction with this industry due to lack of understanding of the nuances involved in the valuation profession. Large organizations and agencies should have a united approach; the perception or reality of a fragmented and uncoordinated strategy is unsettling for prospective partners in the appraisal industry. This requires improved communication and education within and among these communities.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Fundamental understanding of oxygen reduction and reaction behavior and developing high performance and stable hetero-structured cathodes

New unique hetero-structured cathode has been developed in this project. La 2 NiO 4+δ (LNO) as a surface catalyst with interstitial oxygen defects was introduced onto the state-of-the-art (La 0.6 Sr 0.4 ) 0.95 Co 0.2 Fe 0.8 O 3-δ (LSCF) cathode to enhance the surface-limited ORR kinetics on SOFC cathode. Furthermore, the hetero-structured cathode surface maintains high activity under electrode polarization with much less negative effects from surface cation segregation of Sr, which is known to cause degradation issues for conventional LSCF and LSC cathodes, thus improving the cathode long-term stability. The interface chemistry distribution and oxygen transport properties have been studied to prove the enhancement of power out and stability of LNO-infiltrated LSCF cathode. The further investigation demonstrates that CeO 2 & La 2-x NiO 4+δ (x=0-0.2) co-infiltration is a simple and cost-effective method to improve both performance and stability of LSCF cathode by limiting nano-particles growth/delamination and further improve the surface stability. For the first time, a physical model is proposed to illustrate how unique interstitial species on hetero-structured cathode surface work to regulate the exchange rate of the incorporation reaction. Meanwhile, fundamental investigation of the surface oxygen exchange and bulk oxygen transport properties under over-potential conditions across cathode materials have been carried out in this project, which were discussed and compared to the Nernst equation that is generally applied to treat any oxide electrodes under equilibrium.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗