Search NASA⌕ Search

SEARCH · Search NASA

Results for “RADIONUCLIDE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,009 records · Page 56

Potential of hybrid functionalized meso-porous materials for the separation and immobilization of radionuclides

Functionalized meso-porous materials are a class of hybrid organic-inorganic material in which a meso-porous metal oxide framework is functionalized with multifunctional organic molecules. These molecules may contain one or more anchor groups that form strong bonds to the pore surfaces of the metal oxide framework and free functional groups that can impart and or modify the functionality of the material such as for binding metal ions in solution. Such materials have been extensively studied over the past decade and are of particular interest in absorption applications because of the tremendous versatility in choosing the composition and architecture of the metal oxide framework and the nature of the functional organic molecule as well as the efficient mass transfer that can occur through a well-designed hierarchically porous network. A sorbent for nuclear applications would have to be highly selective for particular radio nuclides, it would need to be hydrolytically and radiolytically stable, and it would have to possess reasonable capacity and fast kinetics. The sorbent would also have to be available in a form suitable for use in a column. Finally, it would also be desirable if once saturated with radio nuclides, the sorbent could be recycled or converted directly into a ceramic or glass waste form suitable for direct repository disposal or even converted directly into a material that could be used as a transmutation target. Such a cradle-to- grave strategy could have many benefits in so far as process efficiency and the generation of secondary wastes are concerned.This paper will provide an overview of work done on all of the above mentioned aspects of the development of functionalized meso-porous adsorbent materials for the selective separation of lanthanides and actinides and discuss the prospects for future implementation of a cradle-to-grave strategy with such materials. (author)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Stabilization of Radionuclides and Metals into Spinels Using THOR{sup R} Fluidized Bed Steam Reforming - 12039

Studsvik, Inc.'s Thermal Organic Reduction (THOR) Process has been operating for over 12 years in the treatment of radioactive liquid and solid wastes from commercial Nuclear Power Plants in the United States. A second THOR plant is starting operations in early 2012 for the treatment of radioactive wastes from US nuclear power research at US DOE's Idaho National Laboratory. THOR has long been recognized for its unique ability to substantially reduce the volume of radioactive wastes - via the removal of water and destruction of organics, nitrates/nitrites, etc.- and produce a dry, stable solid product while retaining extremely high amounts (>99.99%) of the incoming wastes' radioactivity. Moreover, the THOR process has demonstrated the ability to produce radioactive waste forms with leach-resistance as good as or better than vitrified glass. An additional facet of the technology which, to this point, has been marginalized is the production spinels that are essential for capturing volatile, leachable, and large radioactive and hazardous inorganic species. These spinels form from the wide variety of inorganics in the incoming waste feed and proprietary additives used in processing. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Construction of the Largest Radionuclide Commingled Plume Groundwater Treatment Facility for the Department of Energy at the Hanford Site - 12411

CH2M Hill Plateau Remediation Company (CHPRC) has constructed the largest groundwater treatment systems of its kind throughout the DOE Complex at the Hanford Site in an accelerated manner with American Recovery and Reinvestment Act (ARRA) funds. This complex, one of a kind groundwater treatment facility in Washington State has also attained Leadership in Energy and Environmental Design (LEED) Gold certification. The original concept for the 200 West Area groundwater treatment facility was a 6100 liter per minute (1,600 gallon per minute) facility. With additional ARRA funding, the plant design was improved to construct a 9500 liter per minute (2,500 gallon per minute) facility with expansion areas up to 14,000 liter per minute (3,750 gallon per minute). The current design will remove 53 percent more mass per year for faster clean-up. It is also expected to treat extracted groundwater to 25 percent or less than the Record of Decision-specified limit which improves Monitored Natural Attenuation (MNA) effectiveness. (author)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Process for Obtaining TI Waiver for Recalcitrant Radionuclides at DOE Sites - 18225

The current plan for treating radioactive iodine-129 ({sup 129}I) at the 200-UP-1 operable unit (OU) within the Central Plateau at the Hanford Site is to hydraulically contain the groundwater plume using injection wells placed at the leading edge of the plume. In the previous feasibility study for the OU, no treatment technologies were identified that could achieve the federal drinking water standard of 1 pCi/L. In addition to further study to identify viable remediation technology options, efforts were initiated to assess the potential human health and environmental risks associated with using hydraulic containment of {sup 129}I, and to refine transport estimates based on evidence of attenuation. An initial step was to develop and apply a waste-site scale integrated vadose zone-aquifer model. Because viable {sup 129}I remediation technologies for the OU may not be identified in current efforts, a process to facilitate examining the suitability of a technical impracticability waiver for the OU conditions was initiated by defining the monitoring data analysis, documentation, and simulation support that would be needed for obtaining a waiver. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Radionuclide Behaviour During Thermal Treatment of LLW and ILW Using In-Container Vitrification - 19239

Thermal treatment is being considered in the UK for the treatment of a wide range of low and intermediate level wastes (LLW and ILW). To support this objective, a range of in-container vitrification trials were conducted to test a wide range of simulated waste streams. The vitrified products have been visually inspected and samples removed for chemical analysis. This paper presents preliminary results of this analysis with some comment on the spatial and chemical heterogeneity of the products. Treatment of a sludge simulant in a steel skip failed to fully melt the metal and produced a glass encapsulated waste-form with clearly visible porosity. Clinoptilolite produced a dense uniform glass but with some chemical heterogeneity. Some operational issues were encountered when treating water-rich sludge, but these were successfully resolved and resulted in a broadly homogenous vitrified product. Melting simulated mixed decommissioning waste produced a chemically homogenous product, despite the heterogenous nature of the waste stream. Uranium and concrete contained in a steel 'top hat' presented significant treatment issues. The top hat failed to fully melt, and this appears to have prevented the waste contained within the top hat from mixing with the glass external to the top hat. As with the steel skip containing sludge, this again left a glass encapsulated, rather than fully vitrified, product. Attempts to melt bulk PVC (an analogue of soft PCM) initially led to significant operational issues with the melt being terminated early and the waste apparently combusting rather than melting. This was resolved by pre-treating the PVC by shredding it and mixing this with the frit to give a larger contact area for melting. This approach produced a homogenous well mixed glass. Overall it appears the properties of the melt product are highly dependent on the physical and chemical properties of the waste stream being treated. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A Comparison of Groundwater Sampling Technologies, Including Passive Diffusion Sampling, for Radionuclide Contamination - 20205

Using traditional high-flow purge methods for long-term water quality monitoring of deep groundwater wells can be expensive, affect contaminant migration, and produce excessive volumes of discharge water that can be difficult to manage. The use of low-flow pumping methods and depth discrete bailers (DDBs) can reduce the cost of sampling deep groundwater wells. In general, using different pumping methods to obtain reproducible and representative groundwater can be challenging. Passive diffusion samplers (PDSs) have successfully been used in long-term monitoring for volatile organic compounds, major ions, and trace-elements, but application has been limited for stable and radioactive isotopes. Beginning in 2018, the United States Geological Survey (USGS) conducted three sampling events to test the ability of PDSs and DDBs to obtain reproducible and representative groundwater samples. The sampled well is completed in a regional, permeable carbonate aquifer and is one in a set of wells that have historically been used for tritium tracer testing. All samples were obtained at 180 m (590 ft) below land surface (bls) in a 13.97 cm (5.5 inch) uncased well that has a total depth of 202 m (662 ft) bls. The first sampling event deployed a regenerated cellulose dialysis membrane (RCDM) PDS for 14 days with deionized water as the blank. The second sampling event deployed a RCDM for 27 days also with deionized water as the blank. The third sampling event deployed a Dual Membrane (DM) PDS for 65 days using a blank of tritium-dead carbonate water. The DM PDS was used to assess the effect of longer term deployment on tritium concentrations and address whether or not the PDSs reached equilibrium with ambient groundwater. The day after each of the three passive samplers were retrieved a DDB was used to obtain discrete non-integrated groundwater samples. For each DDB sampling day, the bailer was lowered into the well 10 consecutive times to determine if the water chemistry changed from the first to the last bailed sample. Quality assurance samples including blanks and duplicates were obtained during all three sampling events. All blank waters had tritium concentrations less than 21±33 pCi/L. Major ion (e.g. calcium, chloride, sodium, and sulfate) results were compared between all samples obtained with RCDM and DDB. Major ion concentrations showed a coefficient of variation of less than 6% between all RCDM and DDB samples; however, the coefficient of variation between the different deployment times and the two different methods for trace-element concentrations was much larger, particularly for manganese (82%), lead (41%), and zinc (33%). Stable isotope values were compared between the RCDM and DDB samples. The DDB sample results all fell within analytical uncertainty and were considered representative of the formation groundwater. The stable isotope values from the RCDM samples indicated that a longer deployment time was necessary to gain equilibrium and to obtain representative groundwater samples. Tritium results from groundwater samples obtained from the RCDM, DM, and DDB indicate that groundwaters obtained with PDSs produced tritium concentrations 2 to 3 times higher (between 1,426 and 3,060±87 pCi/L) than groundwaters obtained with a DDB (479 to 1,219±51 pCi/L). The longer the passive diffusion samplers were deployed, the higher the tritium concentration, suggesting that equilibrium with tritium was not reached within a 27-day deployment. DDB samples showed tritium results declining from the first to the last bailed sample for all three sampling events. This research suggests that tritium results from groundwater samples obtained from PDSs are more reproducible than samples obtained from DDBs. Also, PDSs likely do not accumulate isotopes of water but rather equilibrate with the ambient groundwater. On the other hand, both PDSs and DDBs were able to provide representative groundwater samples for major ions and have the potential to produce representative groundwater samples for stable isotopes of water (δD and δ{sup 18}O). Utilizing the most effective method for sampling groundwater is important for long-term groundwater monitoring. Quantifying the ability of passive diffusion groundwater samplers to obtain representative radioactive chemistry samples will help determine if these methods can be a useful alternative to pumping and purging wells for long-term monitoring. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Methods for producing radionuclides using minimal targeting material

Among the various aspects of the present disclosure is the provision of methods for producing radioisotopes and improving the specific activity of radioisotopes (e.g., Cu-64 chloride). As described herein, the method includes matching of the target material and the proton beam strike area, resulting in improved specific activity while reducing the amount of target material used.

Gaehle, Gregory↗

Multiaxis sensing system for detection of airborne molecules and radionuclides

Various technologies presented herein relate to a method and equipment for detecting both airborne radioisotope and molecular effluent gases. Multi-Axis Sensing can be conducted by utilizing a pressurized MOF sorbent, such as a scintillating Metal-Organic Frameworks (S-MOFs). These MOFs are crystalline nanoporous materials that have synthetic versatility that allow adjustment of pore size, chemical environment, and luminescence properties. A method for detecting an analyte in a fluid sample is provided that comprises: loading a sorbent with a sample fluid, wherein the sorbent comprises a MOF material; pressurizing the sample fluid to increase the fluid in the sorbent thereby making a pressurized sorbent; and detecting ionizing radiation or a chemical property of the analyte in the pressurized sorbent.

Allendorf, Mark D.↗

Production and Improved Separation of Therapeutic Radionuclides Tb-161, Er-165, and Lu-177

This project resulted in the synthesis and utility of new solid-phase extractants using diglycolamide (DGA) extractants grafted onto mesoporous silica. We used DGA ligands that offer multidentate coordination sites for lanthanides and offer pre-arranged binding sites that may facilitate radiolanthanide metal binding. Also, the Hunter graduate student worked at University of Utah on production and separation of 161 Tb with high specific activity resulting in a publication. These are reported in the full text upload.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗