Search NASA⌕ Search

SEARCH · Search NASA

Results for “SEPARATION PROCESSES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,009 records · Page 56

Placement of Hemodialysis Catheters Through Stenotic or Occluded Central Thoracic Veins

A method for hemodialysis catheter placement in patients with central thoracic venous stenosis or occlusion is described and initial results are analyzed. Twelve patients, with a mean age of 63.2 years (42-80 years), with central venous stenosis or occlusion, and who required a hemodialysis catheter were reviewed. All lesions were confirmed by helical CT or phlebography. Five patients had stenosis while seven patients were diagnosed with an occlusion of thoracic central veins. All patients were asymptomatic, without sign of superior vena cava syndrome. After percutaneous transstenotic catheterization or guidewire-based recannalization in occlusions, a balloon dilatation was performed and a stent was placed, when necessary, prior to catheter placement. Technical success was 92%. Three patients had angioplasty alone and nine patients had angioplasty with stent placement. Dialysis catheters were successfully inserted through all recannalized accesses. No immediate complication occurred, nor did any patient develop superior vena cava syndrome after the procedure. The mean follow-up was 21.8 months (range, 8-48 months). Three patients developed a catheter dysfunction with fibrin sheath formation (at 7, 11, and 12 months after catheter placement, respectively). Two were successfully managed by percutaneous endovascular approach and one catheter was removed. In conclusion, for patients with central venous stenosis or occlusion and those who need a hemodialysis catheter, catheter insertion can be reliably achieved immediately after endovascular recannalization with acceptable technical and long-term success rates. This technique should be considered as an alternative procedure for placing a new hemodialysis catheter through a patent vein.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparison of Heparin-Coated and Conventional Split-Tip Hemodialysis Catheters

Catheter coatings have the potential to decrease infection and thrombosis in patients with chronic dialysis catheters. We report our midterm experience with a heparin-coated dialysis catheter. This retrospective, case-control study was approved by our Institutional Review Board. A total of 88 tunneled dialysis catheters were inserted over a 13-month period via the internal jugular vein. Thirty-eight uncoated split-tip catheters and 50 heparin-coated catheters were inserted. Primary catheter patency was compared between the two groups using the log rank test, with infection and/or thrombosis considered as catheter failures. Dialysis parameters during the first and last dialysis sessions, including pump speed, actual blood flow, and arterial port pressures, were compared using unpaired t-tests. Primary patency of the uncoated catheters was 86.0 {+-} 6.5% at 30 days and 76.1 {+-} 8.9% at 90 days. Primary patency of heparin-coated catheters was 92.0 {+-} 6.2% at 30 days and 81.6 {+-} 8.0% at 90 days (p = 0.87, log rank test). Infection requiring catheter removal occurred in four patients with uncoated catheters and two patients with heparin-coated catheters (p = 0.23). Catheter thrombosis requiring catheter replacement or thrombolysis occurred in one patient with an uncoated catheter and two patients with heparin-coated catheters (p = 0.9). No differences in catheter function during hemodialysis were seen between the two groups. In conclusion, the heparin-coated catheter did not show a significantly longer patency compared to the uncoated catheter. The flow characteristics of this device were comparable to those of the conventional uncoated catheter. A demonstrable benefit of the heparin-coated catheter in randomized trials is needed before a recommendation for routine implementation can be made.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Endovascular Treatment of Autogenous Radiocephalic Fistulas with the 'Eighth Note' Deformity for Hemodialysis

The purpose of this paper is to describe a unique 'eighth note' deformity of the autogenous radiocephalic fistula for hemodialysis and to retrospectively evaluate the efficacy and safety of its endovascular treatment. Over 3 years, a total of 808 patients and 558 autogenous radiocephalic fistulas were treated for vascular access dysfunction or thrombosis. These included 14 fistulas in 14 patients (9 men, 5 women; mean age, 58.2 {+-} 2.8 years; range 27-79 years) whose fistulograms before treatment resembled a musical note, the eighth note. Endovascular treatment sought to remodel the deformed vascular access to a classic radiocephalic fistula and increase the number of cannulation sites available for hemodialysis. The technical and clinical success rates were each 92.8% (13/14). Fistula remodeling was successful in 13 patients. The postintervention primary patency was 100% at 90 days, 91.7 {+-} 0.8% at 120 days, 78.6 {+-} 13.9% at 180 days, 62.9 {+-} 17.9% at 360 days, 31.4 {+-} 24.0% at 540 days, and 0% at 720 days. The postintervention secondary patency was 100% at 90 days, 100% at 120 days, 100% at 180 days, 85.7 {+-} 13.2% at 360 days, and 85.7 {+-} 13.2% at 720 days. No major complications were noted. Minor complications were found in 71.4% of patients, all of which resolved spontaneously. In conclusion, endovascular treatment of fistulas with the eighth note deformity can effectively increase the number of available cannulation sites, facilitate fistula maturation, and facilitate thromboaspiration after fistula thrombosis.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Transhepatic Guidance of Translumbar Hemodialysis Catheter Placement in the Setting of Chronic Infrarenal IVC Occlusion

When patients with end-stage renal disease have exhausted both conventional and unconventional venous access options, creative solutions must be sought for hemodialysis catheter placement in order to ensure survival. This case describes a patient in urgent need of a dialysis catheter despite total occlusion of the jugular, subclavian, and femoral veins. Occlusion of the inferior vena cava (IVC) and right renal vein resulted in failed attempts at translumbar catheter placement. A gooseneck snare was temporarily advanced through the liver to the IVC for use as a fluoroscopic target to facilitate successful single-puncture, translumbar catheterization.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Retrospective Comparative Study of Tunneled Haemodialysis Catheters Inserted Through Occluded or Collateral Veins Versus Conventional Methods

Tunneled hemodialysis catheters become essential in dialysis access when there is no possibility of using a functioning arteriovenous fistula. Collateral or occluded veins visible on ultrasound are used for puncture and passage of catheters into the central venous system. Chronically occluded veins are crossed with guidewires to allow dilatation and subsequent passage of hemodialysis catheters. We performed a retrospective analysis of patient demographics, comorbidities, procedural complications, functional survival, performance, and history of previous vascular access. The study group was compared with two control groups in which dialysis catheters were inserted either by radiologists in the interventional suite or by clinicians on the wards. Nineteen patients from the study group were compared with same number of patients in both control groups. The mean age of the study group was higher compared with the control groups. There was no significant difference in mean functional survival, infection rates, dialysis pump speeds in the first 2 weeks, and procedural complications between the study group and the controls. The study group had a significantly higher number of previous vascular access interventions, longer dialysis careers, and more comorbidities. Tunneled dialysis catheter placement by way of collateral or occluded veins appears safe and effective. These techniques give the operator further options when faced with patients possessing challenging vascular access. Indeed, there may be a case for preferential use of these veins to keep patent central veins in reserve.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Effect of Intravascular Iodinated Contrast Media on Natural Course of End-Stage Renal Disease Progression in Hemodialysis Patients: A Prospective Study

We evaluated the impact of intravascular iodinated contrast medium on residual diuresis in hemodialyzed patients. Two groups of clinically stable hemodialyzed patients with residual diuresis minimally 500 ml of urine per day were studied. The patients from the first group were given iso-osmolal contrast agent iodixanol (Visipaque, GE Healthcare, United Kingdom) in concentration of iodine 320 mg/ml with osmolality 290 mOsm/kg of water during the endovascular procedure. The second control group was followed without contrast medium administered. Residual diuresis and residual renal excretory capacity expressed as 24-h calculated creatinine clearance were evaluated in the both groups after 6 months. The evaluated group included 42 patients who were given 99.3 ml of iodixanol in average (range, 60-180 ml). The control group included 45 patients. There was no statistically significant difference found between both groups in daily volume of urine (P = 0.855) and calculated clearance of creatinine (P = 0.573). We can conclude that residual diuresis is not significantly influenced by intravascular administration of iso-osmolal iodinated contrast agent (iodixanol) in range of volume from 60 to 180 ml in comparison to natural course of urinary output and residual renal function during end-stage renal disease. This result can help the nephrologist to decide which imaging method/contrast medium to use in dialyzed patients in current practice.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Early Experience with the Amplatzer Vascular Plug II for Occlusive Purposes in Arteriovenous Hemodialysis Access

The Amplatzer Vascular Plug Type II (AVP II) has proven effective in the therapeutic embolization of various vascular lesions. It benefits from very rapid occlusion of the target lesion and can be deployed, retrieved, and redeployed if required. There is no literature available on use of the AVP II in the maintenance, closure, and management of complicated arteriovenous access in hemodialysis patients. In this series, we present our clinical experience with the use of the AVP II for embolization of problematic hemodialysis access. The AVP II is a self-expandable Nitinol wire-mesh device. Mounted on a delivery wire it has the capability to be deployed, recaptured, and redeployed. In total seven patients (four males: one diabetic, all nonsmokers), with ages ranging from 44 to 81 years (mean, 63 years), were treated between July 2008 and January 2009. One patient had not started dialysis. The remaining six patients had varied histories, with the time on hemodialysis ranging from 1 to 21 years. Retrospective review of clinical notes revealed patient demographics, type of access, device size, deployment site, and outcomes. Indications for embolization included steal syndrome (one patient), high-flow tributaries (two patients), and limb swelling (four patients). All patients had clinical and sonographical follow-up to 3 months. Surgical ligation had either failed, was considered a contraindication due to concerns regarding wound healing, or was considered difficult due to complex venous anatomy. Only one device was used in each patient, ranging from 6 to 16 mm in diameter. Immediate technical success was seen in 100%. All these patients were followed up clinically in the vascular access radiology clinic at 4 weeks and 3 months. Occlusion of the treated vessel and resolution of symptoms were reconfirmed in 100% of cases at 3 months. It was also noted whether patients were having successful dialysis, if required. There were no complications. Average procedural time was 19 min. We conclude that the AVP II is an efficient, safe, and technically simple occlusion device for use in arteriovenous access.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Cutaneous Bronchobiliary Fistula Treated with Tissucol Sealant

Bronchobiliary fistula is a rare and is an uncommon but severe complication of hydatid disease of the liver. Treatment has traditionally been surgical resection, but embolization and stent placement have been described. The invasive method seems to be a key component of patient treatment. We describe a case of a 58-year-old woman who, 25 years before, had undergone surgery for a hydatid cyst. A total cystectomy without previous puncture or parasite extraction was carried out. The lower aspect of the cyst was found to be completely perforated over the biliary duct. During the postoperative course, the patient had subphrenic right-sided pleural effusion and biliary fistula that subsided with medical treatment. Afterward, the patient came to the outpatient area of our hospital complaining of leakage of purulent exudate through the cutaneous opening, pain located on the right hypochondrium radiating to the right hemithorax, malaise, fever, chronic cough, and occasional vomiting of bile. Fistulography revealed an anfractuous cavity communicating with a residual cystic cavity on the right hepatic lobe. We observed communication with the intrahepatic canaliculi. Computed tomographic scan revealed a fistulous tract on the anterior liver border through the abdominal wall. There were no posttreatment complications. The patient is asymptomatic.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

PTA of Infrapopliteal Arteries: Long-term Clinical Follow-up and Analysis of Factors Influencing Clinical Outcome

This study was a retrospective analysis of patients with CLI who underwent infrapopliteal percutaneous transluminal angioplasty (PTA). The main goal was to evaluate clinical and morphological factors that influence the clinical outcome of PTA in long-term follow-up. A total of 1,445 PTA procedures were performed in 1,268 patients. Main indications for PTA included gangrene, nonhealing ulcers, or rest pain. The mean number of treated arteries was 1.77 artery/limb, and the majority of lesions were type TASC D. The technical success rate of PTA was 89% of intended-to-treat arteries. The main criterion of clinical success was functional limb salvage (LS). One-year follow-up involved 1,069 limbs. Primary and secondary 1-year LS rates were 76.1 and 84.4%, respectively. The effect of clinical and morphological parameters on the 1-year LS was that the only associated disease with an adverse effect on LS rate was DM combined with dialysis. Regarding limb preprocedural status, gangrene was clearly a negative predictor. The most important factor affecting LS was the number of patent arteries post-PTA: patients with 0, 1, 2, and 3 patent arteries had 1-year primary LS rates of 56.4, 73.1, 80.4, and 83%, respectively. Long-term follow-up of LS rates demonstrated secondary LS rates of 84.4, 78.8, and 73.3% at 1, 5, and 10 years. Every effort should be made to perform PTA for as many arteries as possible, even if TASC D type, to improve clinical outcome. Our study shows that repeat PTA is capable of keeping the long-term LS rate close to 75%.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Minimally Invasive Catheter Procedures to Assist Complicated Pacemaker Lead Extraction and Implantation in the Operating Room

We report on percutaneous catheter procedures in the operating room (OR) to assist complicated manual extraction or insertion of pacemaker (PM) and implantable cardioverter defibrillator leads. We retrospectively reviewed complicated PM revisions and implantations performed between 2004 and 2009 that required percutaneous catheter procedures performed in the OR. The type of interventional procedure, catheter and retrieval system used, venous access, success rates, and procedural complications were analyzed. In 41 (12 female and 29 male [mean age 62 {+-} 17 years]) of 3021 (1.4%) patients, standard manual retrieval of old leads or insertion of new leads was not achievable and thus required percutaneous catheter intervention for retrieval of misplaced leads and/or recanalisation of occluded central veins. Thirteen of 18 (72.2%) catheter-guided retrieval procedures for misplaced (right atrium [RA] or ventricle [RV; n = 3], superior vena cava [n = 2], brachiocephalic vein [n = 5], and subclavian vein [n = 3]) lead fragments in 16 patients were successful. Percutaneous catheter retrieval failed in five patients because there were extremely fixed or adhered lead fragments. Percutaneous transluminal angiography (PTA) of central veins for occlusion or high-grade stenosis was performed in 25 patients. In 22 of 25 patients (88%), recanalization of central veins was successful, thus enabling subsequent lead replacement. Major periprocedural complications were not observed. In the case of complicated manual PM lead implantation or revision, percutaneous catheter-guided extraction of misplaced lead fragments or recanalisation of central veins can be performed safely in the OR, thus enabling subsequent implantation or revision of PM systems in the majority of patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Improvement of Renal Functions After Embolization of Renal AVF in a Patient Who had been on Dialysis for 5 Years

Recently, ultrasound-guided percutaneous renal biopsy has been used in the diagnosis of renal diseases. Development of an arteriovenous fistula (AVF), which is one of the post-biopsy complications, is not frequently encountered. AVFs are usually asymptomatic; however, they may lead to serious outcomes. We report a 21-year-old patient, who had been on dialysis for 5 years. Due to high blood pressure (230/160 mmHg) and a thrill in the lumbar area detected on physical examination, Doppler examination was performed and a renal AVF was detected. Because the patient had a history of renal biopsy 5 years previously, the fistula was thought to be secondary to the biopsy. After embolization of the AVF, renal functions improved enough to terminate dialysis treatment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Percutaneous Treatment of Biliary Cast Syndrome After Orthotopic Liver Transplantation: Comparison of Mechanical Versus Hydraulic Rheolytic Cast Extraction

Purpose: Biliary cast syndrome (BCS) is the presence of casts within the intrahepatic or extrahepatic biliary system after orthotopic liver transplantation. Our work compares two percutaneous methods for BCS treatment: the mechanical cast-extraction technique (MCE) versus the hydraulic cast-extraction (HCE) technique using a rheolytic system. Materials and Methods: A total of 24 patients were included in the study. Six patients were referred for HCE, and 18 patients were treated with MCE. A statistically significant larger number of sessions was required in the MCE group (21.0, range 11 to 72 sessions) (p = 0.033). Results: Median therapy duration was shorter in the HCE group at 2.4 months (range 2 to 5) compared with 6.7 months (range 3 to 39) in the MCE group (p < 0.001). Both patient acceptance was better and costs for total therapy were 40% less in the HCE group. No significant differences where found concerning clinical and biochemical improvement or graft and patient survival. Conclusion: The use of the hydraulic rheolytic system decreased total therapy time, thereby decreasing the induced inflammation time of the biliary tree. A significant benefit of HCE has been observed in our patients when we compare our results with those of MCE.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Optimization of Doxorubicin Loading for Superabsorbent Polymer Microspheres: in vitro Analysis

Purpose: This study was designed to establish the ability of super-absorbent polymer microspheres (SAP) to actively uptake doxorubicin and to establish the proof of principle of SAP's ability to phase transfer doxorubicin onto the polymer matrix and to elute into buffer with a loading method that optimizes physical handling and elution characteristics. Methods: Phase I: 50-100 {mu}m SAP subject to various prehydration methods (normal saline 10 cc, hypertonic saline 4 cc, iodinated contrast 10 cc) or left in their dry state, and combined with 50 mg of clinical grade lyophilized doxorubicin reconstituted with various methods (normal saline 10 cc and 25 cc, sterile water 4 cc, iodinated contrast 5 cc) were placed in buffer and assessed based on loading, handling, and elution utilizing high-performance liquid chromatography (HPLC). Phase II: top two performing methods were subject to loading of doxorubicin (50, 75, 100 mg) in a single bolus (group A) or as a serial loading method (group B) followed by measurement of loading vs. time and elution vs. time. Results: Phase I revealed the most effective loading mechanisms and easiest handling to be dry (group A) vs. normal saline prehydrated (group B) SAP with normal saline reconstituted doxorubicin (10 mg/mL) with loading efficiencies of 83.1% and 88.4%. Phase II results revealed unstable behavior of SAP with 100 mg of doxorubicin and similar loading/elution profiles of dry and prehydrated SAP, with superior handling characteristics of group B SAP at 50 and 75 mg. Conclusions: SAP demonstrates the ability to load and bulk phase transfer doxorubicin at 50 and 75 mg with ease of handling and optimal efficiency through dry loading of SAP.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Staphylococcus-Infected Tunneled Dialysis Catheters: Is Over-the-Wire Exchange an Appropriate Management Option?

Purpose: Over-the-wire exchange of tunneled dialysis catheters is the standard of care per K/DOQI guidelines for treating catheter-related bacteremia. However, Gram-positive bacteremia, specifically with staphylococcus species, may compromise over-the-wire exchange due to certain biological properties. This study addressed the effectiveness of over-the-wire exchange of staphylococcus-infected tunneled dialysis catheters compared with non-staphylococcus-infected tunneled dialysis catheters. Methods: Patients who received over-the-wire exchange of their tunneled dialysis catheter due to documented or suspected bacteremia were identified from a QA database. Study patients (n = 61) had positive cultures for Staphylococcus aureus, Staphylococcus epidermidis, or coagulase-negative staphylococcus not otherwise specified. Control patients (n = 35) received over-the-wire exchange of their tunneled dialysis catheter due to infection with any organism besides staphylococcus. Overall catheter survival and catheter survival among staphylococcal species were assessed. Results: There was no difference in tunneled dialysis catheter survival between study and control groups (P = 0.46). Median survival time was 96 days for study catheters and 51 days for controls; survival curves were closely superimposed. There also was no difference among the three staphylococcal groups in terms of catheter survival (P = 0.31). The median time until catheter removal was 143 days for SE, 67 days for CNS, and 88 days for SA-infected catheters. Conclusions: There is no significant difference in tunneled dialysis catheter survival between over-the-wire exchange of staphylococcus-infected tunneled dialysis catheters and those infected with other organisms.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Percutaneous Transhepatic Removal of Bile Duct Stones: Results of 261 Patients

Purpose: To determine the effectiveness of percutaneous transhepatic removal of bile duct stones when the procedure of endoscopic therapy fails for reasons of anatomical anomalies or is rejected by the patient. Methods: Between April 2001 and May 2010, 261 patients (138 male patients and 123 female patients; age range, 14-92 years; mean age, 64.6 years) with bile duct stones (common bile duct [CBD] stones = 248 patients and hepatolithiasis = 13 patients) were included in the study. First, percutaneous transhepatic cholangiography was performed and stones were identified. Percutaneous transhepatic balloon dilation of the papilla of Vater was performed. Then stones were pushed out into the duodenum with a Fogarty balloon catheter. If the stone diameter was larger than 15 mm, then basket lithotripsy was performed before balloon dilation. Results: Overall success rate was 95.7%. The procedure was successful in 97.5% of patients with CBD stones and in 61.5% of patients with hepatolithiasis. A total of 18 (6.8%) major complications, including cholangitis (n = 7), subcapsular biloma (n = 4), subcapsular hematoma (n = 1), subcapsular abscess (n = 1), bile peritonitis (n = 1), duodenal perforation (n = 1), CBD perforation (n = 1), gastroduodenal artery pseudoaneurysm (n = 1), and right hepatic artery transection (n = 1), were seen after the procedure. There was no mortality. Conclusion: Our experience suggests that percutaneous transhepatic stone expulsion into the duodenum through the papilla is an effective and safe approach in the nonoperative management of the bile duct stones. It is a feasible alternative to surgery when endoscopic extraction fails or is rejected by the patient.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Mathematical modeling of mass transfer during centrifugal filtration of polydisperse suspensions

A mass-transfer equation, the solution of which for given boundary conditions makes it possible to derive in analytical form a relationship between the extraction of the solid phase of a suspension into the centrifuge effluent and the fineness of the particles, is suggested on the basis of a model; this is of particular importance in connection with the development of a new trend in the utilization of filtering centrifuges - concentration of coal slurries by extraction into the centrifuge effluent of the finest particles, the ash content of which is substantially higher than that of particles of the coarser classes. Results are presented for production studies under conditions at an active establishment (the Neryungrinskaya Enrichment Factory); these results confirmed the adequacy of the mathematical model proposed: convergence of computed and experimental data was within the limits of the experimental error (no more than 3%). The model in question can be used to predict results of suspension separation by centrifugal filtration.

01 COAL, LIGNITE, AND PEAT↗