Search NASA⌕ Search

SEARCH · Search NASA

Results for “STORAGE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,009 records · Page 56

System impacts of accelerated transfer of used nuclear fuel to dry storage - 15220

In the wake of the September 11, 2001 terror attacks, and again after the March 11, 2011, accident at the Fukushima Dai-Ichi station from the Great East Japan Earthquake/tsunami, concern was expressed regarding security of current spent fuel storage practices in the United States. An approach recurrently proposed to reduce the potential for fire and the release of radionuclides in an accident or sabotage scenario is to reduce the loading of the reactor fuel pools, which are frequently maintained near their full capacity at many reactor sites in the U.S. We assess the impact on the waste management system of different scenarios for accelerating the schedule of used nuclear fuel (UNF) transfer from reactor pools to dry storage casks. We consider scenarios where the spent fuel pools are drawn down to 50% or 25% of full capacity over 5- or 10-year schedules. The scenarios include status quo, where UNF continues to remain in dry storage at the reactor sites, as well as scenarios with UNF transfer to interim storage and eventually to a mined geologic repository. The primary purpose is to evaluate how the different scenarios for accelerating the transfer of UNF to at-reactor dry storage would affect the performance of the entire UNF management system. Areas that were considered include an estimate of the additional system costs that could be incurred and where the existing infrastructure at the reactor sites would come under stress from the transfer demands. This study considered only the fuel-handling logistics and rough-order-of-magnitude cost at reactor sites, interim storage facility, and operations to package UNF into disposal canisters. The effects of minimum fuel age that could be transferred and the accelerated transfer starting date are also examined, but found to have relatively little effect. Impacts on safety and worker dose are not evaluated quantitatively, although effects can be inferred from increases in handling operations, etc. from the scenarios considered. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Amineborane Based Chemical Hydrogen Storage - Final Report

The development of efficient and safe methods for hydrogen storage is a major hurdle that must be overcome to enable the use of hydrogen as an alternative energy carrier. The objectives of this project in the DOE Center of Excellence in Chemical Hydride Storage were both to develop new methods for on-demand, low temperature hydrogen release from chemical hydrides and to design high-conversion off-board methods for chemical hydride regeneration. Because of their reactive protic (N-H) and hydridic (B-H) hydrogens and high hydrogen contents, amineboranes such as ammonia borane, NH3BH3 (AB), 19.6-wt% H2, and ammonia triborane NH3B3H7 (AT), 17.7-wt% H2, were initially identified by the Center as promising, high-capacity chemical hydrogen storage materials with the potential to store and deliver molecular hydrogen through dehydrogenation and hydrolysis reactions. In collaboration with other Center partners, the Penn project focused both on new methods to induce amineborane H2-release and on new strategies for the regeneration the amineborane spent-fuel materials. The Penn approach to improving amineborane H2-release focused on the use of ionic liquids, base additives and metal catalysts to activate AB dehydrogenation and these studies successfully demonstrated that in ionic liquids the AB induction period that had been observed in the solid-state was eliminated and both the rate and extent of AB H2-release were significantly increased. These results have clearly shown that, while improvements are still necessary, many of these systems have the potential to achieve DOE hydrogen-storage goals. The high extent of their H2­-release, the tunability of both their H2 materials weight-percents and release rates, and their product control that is attained by either trapping or suppressing unwanted volatile side products, such as borazine, continue to make AB/ionic­-liquid based systems attractive candidates for chemical hydrogen storage applications. These studies also demonstrated that H2-­release from chemical hydrides can occur by a number of different mechanistic pathways and strongly suggest that optimal chemical ­hydride based H2­release systems may require the use of synergistic dehydrogenation methods to induce H2­-loss from chemically different intermediates formed during release reactions. The efficient regeneration of ammonia borane from BNHx spent fuel is one of the most challenging problems that will have to be overcome in order to utilize AB-based hydrogen storage. Three Center partners, LANL, PNNL and Penn, each took different complimentary approaches to AB regeneration. The Penn approach focused on a strategy involving spent-fuel digestion with superacidic acids to produce boron-halides (BX3) that could then be converted to AB by coordination/reduction/displacement processes. While the Penn boron-halide reduction studies successfully demonstrated that a dialkylsulfide-based coordination/reduction/displacement process gave quantitative conversions of BBr3 to ammonia borane with efficient and safe product separations, the fact that AB spent-fuels could not be digested in good yields to BX3 halides led to a No-Go decision on this overall AB-regeneration strategy.

08 HYDROGEN↗

Equitable Resilience: Opportunities to Advance Solar Paired with Battery Storage in Historically Marginalized Communities

This report was produced as part of the Equitable Solar Communities of Practice program through the U.S. Department of Energy (DOE) Solar Energy Technologies Office (SETO). Clean Energy Group (CEG) managed the Resilience, Storage, and Grid Benefits Community of Practice, which aimed to research, evaluate, and identify opportunities to scale the meaningful benefits of solar paired with battery storage in historically marginalized communities. The report is designed to 1) educate a broad audience on the benefits of solar paired with battery storage, 2) identify barriers to deploying solar paired with battery storage in historically marginalized communities, 3) amplify early-adopters and innovative programs that support battery storage access across the nation, and 4) recommend best practices for programs and policies to adopt in advancing equitable access to solar and battery storage technologies.

14 SOLAR ENERGY↗

TECHNOLOGY DEVELOPMENT AND DEPLOYMENT OF SYSTEMS FOR THE RETRIEVAL AND PROCESSING OF REMOTE-HANDLED SLUDGE FROM HANFORD K-WEST FUEL STORAGE BASIN

In 2011, significant progress was made in developing and deploying technologies to remove, transport, and interim store remote-handled sludge from the 105-K West Fuel Storage Basin on the Hanford Site in south-central Washington State. The sludge in the 105-K West Basin is an accumulation of degraded spent nuclear fuel and other debris that collected during long-term underwater storage of the spent fuel. In 2010, an innovative, remotely operated retrieval system was used to successfully retrieve over 99.7% of the radioactive sludge from 10 submerged temporary storage containers in the K West Basin. In 2011, a full-scale prototype facility was completed for use in technology development, design qualification testing, and operator training on systems used to retrieve, transport, and store highly radioactive K Basin sludge. In this facility, three separate systems for characterizing, retrieving, pretreating, and processing remote-handled sludge were developed. Two of these systems were successfully deployed in 2011. One of these systems was used to pretreat knockout pot sludge as part of the 105-K West Basin cleanup. Knockout pot sludge contains pieces of degraded uranium fuel ranging in size from 600 {mu}m to 6350 {mu}m mixed with pieces of inert material, such as aluminum wire and graphite, in the same size range. The 2011 pretreatment campaign successfully removed most of the inert material from the sludge stream and significantly reduced the remaining volume of knockout pot product material. Removing the inert material significantly minimized the waste stream and reduced costs by reducing the number of transportation and storage containers. Removing the inert material also improved worker safety by reducing the number of remote-handled shipments. Also in 2011, technology development and final design were completed on the system to remove knockout pot material from the basin and transport the material to an onsite facility for interim storage. This system is scheduled for deployment in 2012. The prototype facility also was used to develop technology for systems to retrieve remote-handled transuranic sludge smaller than 6350 {mu}m being stored in underwater containers. After retrieving the sludge, the system will be used to load and transport the sludge for interim storage. During 2011, full-scale prototype systems were developed and tested to a Technology Readiness Level 6 as defined by U.S. Department of Energy standards. This system is scheduled for deployment in 2013. Operations also are scheduled for completion in 2014.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Ice Thermal Storage Systems for LWR Supplemental Cooling and Peak Power Shifting

Availability of enough cooling water has been one of the major issues for the nuclear power plant site selection. Cooling water issues have frequently disrupted the normal operation at some nuclear power plants during heat waves and long draught. The issues become more severe due to the new round of nuclear power expansion and global warming. During hot summer days, cooling water leaving a power plant may become too hot to threaten aquatic life so that environmental regulations may force the plant to reduce power output or even temporarily to be shutdown. For new nuclear power plants to be built at areas without enough cooling water, dry cooling can be used to remove waste heat directly into the atmosphere. However, dry cooling will result in much lower thermal efficiency when the weather is hot. One potential solution for the above mentioned issues is to use ice thermal storage systems (ITS) that reduce cooling water requirements and boost the plant’s thermal efficiency in hot hours. ITS uses cheap off-peak electricity to make ice and uses those ice for supplemental cooling during peak demand time. ITS is suitable for supplemental cooling storage due to its very high energy storage density. ITS also provides a way to shift large amount of electricity from off peak time to peak time. Some gas turbine plants already use ITS to increase thermal efficiency during peak hours in summer. ITSs have also been widely used for building cooling to save energy cost. Among three cooling methods for LWR applications: once-through, wet cooling tower, and dry cooling tower, once-through cooling plants near a large water body like an ocean or a large lake and wet cooling plants can maintain the designed turbine backpressure (or condensation temperature) during 99% of the time; therefore, adding ITS to those plants will not generate large benefits. For once-through cooling plants near a limited water body like a river or a small lake, adding ITS can bring significant economic benefits and avoid forced derating and shutdown during extremely hot weather. For the new plants using dry cooling towers, adding the ice thermal storage systems can effectively reduce the efficiency loss and water consumption during hot weather so that new LWRs could be considered in regions without enough cooling water. \ This paper presents the feasibility study of using ice thermal storage systems for LWR supplemental cooling and peak power shifting. LWR cooling issues and ITS application status will be reviewed. Two ITS application case studies will be presented and compared with alternative options: one for once-through cooling without enough cooling for short time, and the other with dry cooling. Because capital cost, especially the ice storage structure/building cost, is the major cost for ITS, two different cost estimation models are developed: one based on scaling method, and the other based on a preliminary design using Building Information Modeling (BIM), an emerging technology in Architecture/Engineering/Construction, which enables design options, performance analysis and cost estimating in the early design stage.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Change Agent: Energy Storage as a Driver of Regulatory Evolution

Purpose of Review Dividing the electric grid into the functions of generation, transmission, anddistribution enabled the drawing of jurisdictional lines and the application of the U.S.Constitution’s federalist system to energy regulation. Energy storage technologies,which can be placed throughout the grid to increase flexibility, can provide serviceacross all three of those functions. But the jurisdictional boundaries that have beendrawn around those functions have created barriers that restrict energy storagetechnologies from achieving their full potential. This review analyzes regulatory changes made to reduce barriers to storage deployment and their broader impacts on energy regulation in the U.S. Recent Findings Major energy regulations promulgated at the state and federal levels have generally focused on liberalizing the U.S. electric system through deregulation and increased competition. Paradoxically, however, these efforts have erected strict regulatory barriers that prevent energy storage technologies from providing service across multiple functions. A new wave of regulations in recent years has endeavored to reduce and remove those barriers. Summary Energy regulations adopted in recent years to reduce barriers to energy storage functionality in recent years have had deep and far-reaching impacts on U.S. electric regulation. These impacts go beyond storage and affect all energy technologies. This paper traces the development of energy regulation in U.S., the functional barriers that they created that impede energy storage functionality, recent efforts to remove those barriers, and the broader effects of those efforts. It concludes with a brief discussion of remaining barriers that prevent energy storage from reaching their full potential on the U.S. electric grid.

24 POWER TRANSMISSION AND DISTRIBUTION↗

General volume sizing strategy for thermal storage system using phase change material for concentrated solar thermal power plant

With an auxiliary large capacity thermal storage using phase change material (PCM), Concentrated Solar Power (CSP) is a promising technology for high efficiency solar energy utilization. In a thermal storage system, a dual-media thermal storage tank is typically adopted in industry for the purpose of reducing the use of the heat transfer fluid (HTF) which is usually expensive. While the sensible heat storage system (SHSS) has been well studied, a dual-media latent heat storage system (LHSS) still needs more attention and study. The volume sizing of the thermal storage tank, considering daily cyclic operations, is of particular significance. In this paper, a general volume sizing strategy for LHSS is proposed, based on an enthalpy-based 1D transient model. One example was presented to demonstrate how to apply this strategy to obtain an actual storage tank volume. With this volume, a LHSS can supply heat to a thermal power plant with the HTF at temperatures above a cutoff point during a desired 6 hours of operation. This general volume sizing strategy is believed to be of particular interest for the solar thermal power industry.

14 SOLAR ENERGY↗

Heterogeneity-assisted carbon dioxide storage in marine sediments

Global climate change is a pressing problem caused by the accumulation of anthropogenic greenhouse gas emissions in the atmosphere. Carbon dioxide (CO 2 ) capture and storage is a promising component of a portfolio of options to stabilize atmospheric CO 2 concentrations. Meaningful capture and storage requires the permanent isolation of enormous amounts of CO 2 away from the atmosphere. In this paper, we investigate the effectiveness of heterogeneity-induced trapping mechanism, in potential synergy with a self-sealing gravitational trapping mechanism, for secure CO 2 storage in marine sediments. We conduct the first comprehensive study on heterogeneous marine sediments with various thicknesses at various ocean depths. Prior studies of gravitational trapping have assumed homogeneous (deep-sea) sediments, but numerous studies suggest reservoir heterogeneity may enhance CO 2 trapping. Heterogeneity can deter the upward migration of CO 2 and prevent leakage through the seafloor into the seawater. Using geostatistically-based Monte Carlo simulations of CO 2 transport in heterogeneous sediment, we show that strong spatial variability in permeability is a dominant physical mechanism for secure CO 2 storage in marine sediments below 1.2 km water depth (less than half of the depth needed for the gravitational trapping). We identify thresholds for sediment thickness, mean permeability and porosity, and their relationships to meaningful injection rates. Our results for the U.S. Gulf of Mexico suggest that heterogeneity-assisted trapping has a greater areal extent with more than three times the CO 2 storage capacity for secure offshore CO 2 storage than with gravitational trapping. Finally, these characteristics offer CO 2 storage opportunities that are closer to coasts, more accessible, and likely to be less costly.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Experimental demonstration of a dispatchable latent heat storage system with aluminum-silicon as a phase change material

In this work, we present the design, construction, and experimental results of a prototype latent heat thermal energy storage system. The prototype consists of a thermal storage tank with 100 kg of the aluminum-silicon eutectic as a phase change material, a valved thermosyphon that controls heat flow from the thermal storage tank to the power block, and thermoelectric generators for conversion of heat to electricity. We tested the prototype over four simulated days, where each day consisted of four phases of operation: charging, discharging, simultaneous charging and discharging, and storage. Our results show three major conclusions. First, the thermal energy storage system was able to receive and distribute heat with small temperature gradients - less than 5 degrees C throughout the thermal storage tank. Second, the valved thermosyphon was able to effectively control heat transfer, demonstrating an on/off thermal conductance ratio of 430. Third, the interfaces between subsystems had small temperature drops: of the ~ 560 degrees C temperature drop from the thermal storage tank to the heat rejection system, ~ 525 degrees C occurred across the power block. This work overcomes the challenges of integrating previously-developed subsystems together, providing a proof-of-concept of this system.

14 SOLAR ENERGY↗

Integration of renewable energy generation and storage systems for emissions reduction in an islanded campus microgrid

Microgrid connected building communities are projected to play an integral part in the clean energy transition. These types of systems, when integrated with distributed energy resources (DERs) such as combined heat and power (CHP), district heating and cooling, renewable generation, and energy storage, can provide clean, reliable power to critical facilities and vulnerable communities. The intermittent nature of renewable generation is a challenge when integrating renewables into any grid system, but particularly in islanded microgrids. The University of Texas at Austin (UT) operates an islanded microgrid powered by a CHP plant, while also utilizing district heating and cooling systems and thermal energy storage (TES). High fidelity operating data was used to develop a validated reduced order model of UT’s integrated campus energy systems to serve as a testbed for use in a case study. Hypothetical renewable energy installations on land owned by UT in west Texas were modeled and integrated into the validated campus models along with battery energy storage (BES). Simulations showed that a combination of renewable energy from wind, and optimally controlled 24-hour thermal and battery storage systems could reduce carbon dioxide emissions on campus by 45.4%. The additional retrofit of burner systems to utilize hydrogen natural gas blends resulted in an overall annual emissions reduction of 54.7%. Carbon capture and storage eliminated the majority of the remaining emissions with increased plant energy expenditure. The presented simulations display the practical limitations of a CHP system complemented by renewable generation and short-term storage in eliminating emissions. Furthermore, results highlight the need for further research and development in long duration storage technologies and hydrogen fueled turbines to increase penetration of renewable energy and reduce emissions.

CHP↗

Integration of end-user Cloud storage for CMS analysis

End-user Cloud storage is increasing rapidly in popularity in research communities thanks to the collaboration capabilities it offers, namely synchronisation and sharing. CERN IT has implemented a model of such storage named, CERNBox, integrated with the CERN AuthN and AuthZ services. To exploit the use of the end-user Cloud storage for the distributed data analysis activity, the CMS experiment has started the integration of CERNBox as a Grid resource. This will allow CMS users to make use of their own storage in the Cloud for their analysis activities as well as to benefit from synchronisation and sharing capabilities to achieve results faster and more effectively. It will provide an integration model of Cloud storages in the Grid, which is implemented and commissioned over the world’s largest computing Grid infrastructure, Worldwide LHC Computing Grid (WLCG). In this paper, we present the integration strategy and infrastructure changes needed in order to transparently integrate end-user Cloud storage with the CMS distributed computing model. We describe the new challenges faced in data management between Grid and Cloud and how they were addressed, along with details of the support for Cloud storage recently introduced into the WLCG data movement middleware, FTS3. Finally, the commissioning experience of CERNBox for the distributed data analysis activity is also presented.

97 MATHEMATICS AND COMPUTING↗

Statistical analysis of historic hydrocarbon production data from Gulf of Mexico oil and gas fields and application to dynamic capacity assessment in CO 2 storage

Numerical modeling of CO 2 injection and reservoir flow is typically performed to forecast the number of wells, sustainable injection rates, and total storage volume (or mass). A critical determination for CO 2 storage in depleted oil and gas reservoirs is characterization of reservoir compartmentalization which informs boundary conditions in simulating injection scenarios. Constraining boundary conditions during CO 2 injection into geological formations is a key factor for feasible deployment project. Production history data from 616 wells in 100 oil and gas fields from Gulf of Mexico (GOM) offshore basin can be used to evaluate boundary conditions and total production (oil and gas) and therefor constrain the capacity for potential carbon storage. In general, the combination of decline curve analysis and statistical analysis (to specify constraining boundary conditions) allows the determination of the range of reservoir performance if existing inactive production wells in GOM area of study are used reversibly for CO 2 injection. To constrain the mass of CO 2 which can be injected, it is useful to consider estimates of cumulative bulk (hydrocarbon + brine) production (CBP), which can be converted to equivalent CO 2 mass considering reservoir conditions. Summary CBP statistics are presented as a probability of non-exceedance (PNE), providing a forecast of likely injection rates and masses for other located CO 2 storage projects with similar geology and boundary conditions in the future. The 50% PNE for Equivalent CO 2 is a novel quantitative approach to investigate the possible injection capacity in CO 2 storage projects. The PNE sensitivity analysis shows that reservoir age, drive mechanism, reservoir trap, and reservoir porosity are the key controlling parameters for productivity and consequently optimum CO 2 storage capacity. Furthermore another key finding is the negligible correlation between CBP with reservoir transmissivity and porosity, which implies that other factors than just petrophysical parameters should be studied as constraining factors for CO 2 storage statistical analysis.

42 ENGINEERING↗

Empirical profiling of cold hydrogen plumes formed from venting of LH 2 storage vessels

Liquid hydrogen (LH 2 ) storage is viewed as a viable approach to assure sufficient hydrogen capacity at commercial fuelling stations. Presently, LH 2 is produced at remote facilities and then transported to the end-use site by road vehicles (i.e., LH 2 tanker trucks). Venting of hydrogen to depressurize the transport storage tank is a routine part of the LH 2 delivery and site transfer process. The behavior of cold hydrogen plumes has not been well characterized because of the sparsity of empirical field data, which can lead to overly conservative safety requirements. Committee members of the National Fire Protection Association (NFPA) Standard 2 [1] formed the Hydrogen Storage Safety Task Group, which consists of hydrogen producers, safety experts, and computational fluid dynamics modellers, has identified the lack of understanding of hydrogen dispersion during LH 2 venting of storage vessels as a critical gap for establishing safety distances at LH 2 facilities, especially commercial hydrogen fuelling stations. To address this need, the National Renewable Energy Laboratory Sensor Laboratory, in collaboration with the NFPA Hydrogen Storage Task Group, developed a prototype Cold Hydrogen Plume Analyzer to empirically characterize the hydrogen plume formed during LH 2 storage tank venting. The prototype analyzer was field deployed during an actual LH 2 venting process. Critical findings included: hydrogen above the lower flammable limit (LFL) was detected as much as 2 m lower than the release point, which is not predicted by existing models; personal monitors detected hydrogen at ground level, although at levels below the LFL; a small but inconsistent correlation was found between oxygen depletion and the hydrogen concentration; a negligible to non-existent correlation was found between in-situ temperature measurements and the hydrogen concentration. The prototype analyzer is being upgraded for enhanced metrological capabilities, including improved real-time spatial and temporal profiling of hydrogen plumes and tracking of prevailing weather conditions. Additional deployments are planned to monitor plume behavior under different wind, humidity, and temperature conditions. The data will be shared with the Hydrogen Storage Task Group and ultimately will be used support theoretical models and code requirements prescribed in NFPA 2.

08 HYDROGEN↗

Spontaneous sodium ion storage behaviors of reduced graphene oxide anodes exceeding 100% Coulombic efficiency by modulated ion solvation

Rechargeable batteries are essential energy storage devices that power portable devices and electrical vehicles throughout the world. In general, it is thought that the electrochemical performance of rechargeable batteries is mostly determined by the electrodes within them and that the electrolyte plays a relatively passive role. However, ion transport and storage can be greatly influenced by the electrolyte solution structure, specifically, ion solvation within the bulk and ion desolvation across the electrode/electrolyte interfaces. Herein, we studied the role of the electrolyte as an active component of electrochemical energy storage devices. We found that with an appropriate electrolyte formulation, ion storage in disordered carbonaceous anode materials can occur spontaneously without externally supplied electrical energy. Reduced graphene oxide (RGO) in an ether-based electrolyte demonstrates ‘spontaneous' ion storage behaviors of adsorbing and inserting the solvated ions utilizing facilitated permeability and wettability of RGO, which results in Coulombic efficiency of ~145% due to additional charging capacity of ~180 mAh g -1 during electrochemical processes. The unexpected spontaneous ion storage behavior was extensively investigated using a combination of electrochemical analyses and diagnostics, advanced characterizations, and computational simulation. In conclusion, we believe the spontaneous ion storage behavior offers a new way to further improve the energy efficiency of practical rechargeable batteries.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Influence of the pore size in multi-walled carbon nanotubes on the hydrogen storage behaviors

Activated multi-walled carbon nanotubes (A-MWCNTs) were prepared using a chemical activation method to obtain well-developed pore structures for use as hydrogen storage materials. The microstructure and crystallinity of the A-MWCNTs were evaluated by X-ray diffraction and Fourier transform Raman spectroscopy. The textural properties of the A-MWCNTs were investigated by nitrogen gas sorption analysis at 77 K. The hydrogen storage capacity of the A-MWCNTs was evaluated at 77 K and 1 bar. The results showed that the specific surface area of the MWCNTs increased from 327 to 495 m{sup 2}/g as the activation temperature was increased. The highest hydrogen storage capacity was observed in the A-MWCNTs sample activated at 900 Degree-Sign C (0.54 wt%). This was attributed to it having the narrowest microporosity, which is a factor closely related to the hydrogen storage capacity. This shows that the hydrogen storage behaviors depend on the pore volume. Although a high pore volume is desirable for hydrogen storage, it is also severely affected if the pore size in the A-MWCNTs for the hydrogen molecules is suitable for creating the activation process. Highlights: Black-Right-Pointing-Pointer The AT-800 and AT-900 samples were prepared by a chemical activation method at activation temperature of 800 and 900 Degree-Sign C, respectively. Black-Right-Pointing-Pointer The AT-900 sample has the narrowest peak in comparison with the AT-800 sample, resulting from the overlap of the two peaks (Peak I and Peak II). Black-Right-Pointing-Pointer This overlapping effect is due to the newly created micropores or shrinkages of pores in Peak II. So, these determining characteristics are essential for designing materials that are suitable for molecular hydrogen storage.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

High-temperature thermochemical energy storage based on redox reactions using Co-Fe and Mn-Fe mixed metal oxides

Metal oxides are potential materials for thermochemical heat storage via reversible endothermal/exothermal redox reactions, and among them, cobalt oxide and manganese oxide are attracting attention. The synthesis of mixed oxides is considered as a way to answer the drawbacks of pure metal oxides, such as slow reaction kinetics, loss-in-capacity over cycles or sintering issues, and the materials potential for thermochemical heat storage application needs to be assessed. This work proposes a study combining thermodynamic calculations and experimental measurements by simultaneous thermogravimetric analysis and calorimetry, in order to identify the impact of iron oxide addition to Co and Mn-based oxides. Fe addition decreased the redox activity and energy storage capacity of Co{sub 3}O{sub 4}/CoO, whereas the reaction rate, reversibility and cycling stability of Mn{sub 2}O{sub 3}/Mn{sub 3}O{sub 4} was significantly enhanced with added Fe amounts above ~15 mol%, and the energy storage capacity was slightly improved. The formation of a reactive cubic spinel explained the improved re-oxidation yield of Mn-based oxides that could be cycled between bixbyite and cubic spinel phases, whereas a low reactive tetragonal spinel phase showing poor re-oxidation was formed below 15 mol% Fe. Thermodynamic equilibrium calculations predict accurately the behavior of both systems. The possibility to identify other suitable mixed oxides becomes conceivable, by enabling the selection of transition metal additives for tuning the redox properties of mixed metal oxides destined for thermochemical energy storage applications. - Highlights: • Solar thermochemical energy storage via reduction/oxidation of mixed metal oxides. • Co-Fe and Mn-Fe mixed oxides are promising candidates for high-temperature energy storage. • Improved cycling of Mn{sub 2}O{sub 3} between bixbyite and cubic spinel by adding 15–50 mol% Fe. • Co{sub 3}O{sub 4} and Mn{sub 2}O{sub 3} reaction temperature and hysteresis gap tuned with Fe addition. • Validation of calculated phase diagram by comparison with experimental results.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

High energy storage properties of (Ni1/3Nb2/3)4+ complex-ion modified (Ba0.85Ca0.15)(Zr0.10Ti0.90)O3 ceramics

Highlights: • BCZT-xNN ceramics showed single phase perovskite structure without an obvious second phase after adding NN, and exhibited both good temperature (−55 to 160 °C) and frequency (10{sup 2}–10{sup 7} Hz) stability. • The highest energy storage density can reach 0.66 J/cm{sup 3} and the energy efficiency is 88.1% was achieved in x = 0.3. • The environmental friendly (lead-free) BCZT-xNN ceramics are good candidate for application in energy storage devices. • This paper also developes a new method to obtain high energy storage density and efficiency of ceramic capacitor, which aims to adjust the T{sub c} of ceramics far below room temperature. - Abstract: In this study, paraelectric ceramics, (Ba{sub 0.85}Ca{sub 0.15})(Zr{sub 0.10}Ti{sub 0.90}){sub 1-x}(Ni{sub 1/3}Nb{sub 2/3}){sub x}O{sub 3,} abbreviated as BCZT-xNN (with x = 0.1, 0.2, 0.3, 0.4) were prepared via a solid-state reaction method. By introducing a B-site complex-ion, (Ni{sub 1/3}Nb{sub 2/3}){sup 4+}, the Curie temperature of the ceramic could be reduced to below room temperature. The effects of this B-site (Ni{sub 1/3}Nb{sub 2/3}){sup 4+} complex-ion substitution on the phase structure, surface microstructure as well as the dielectric, ferroelectric, and energy storage properties of the ceramic were systematically investigated. After adding NN, BCZT-xNN shows a single phase perovskite structure without evidence of a second phase . In addition, we observed high stability with respect to both temperature (−55 to 160 °C) and frequency (10{sup 2}–10{sup 7} Hz). Doping with NN produces slim polarization-electric field hysteresis loops and enhanced energy storage properties, while the efficiency decreases. When x = 0.3, the highest energy storage density reached 0.66 J/cm{sup 3} for a high electric field (20 kV/mm), and the respective energy efficiency was 88.1%. These properties indicate that the environmental friendly BCZT-xNN ceramics are promising candidates for commercial energy storage devices.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

New insights into designing metallacarborane based room temperature hydrogen storage media

Metallacarboranes are promising towards realizing room temperature hydrogen storage media because of the presence of both transition metal and carbon atoms. In metallacarborane clusters, the transition metal adsorbs hydrogen molecules and carbon can link these clusters to form metal organic framework, which can serve as a complete storage medium. Using first principles density functional calculations, we chalk out the underlying principles of designing an efficient metallacarborane based hydrogen storage media. The storage capacity of hydrogen depends upon the number of available transition metal d-orbitals, number of carbons, and dopant atoms in the cluster. These factors control the amount of charge transfer from metal to the cluster, thereby affecting the number of adsorbed hydrogen molecules. This correlation between the charge transfer and storage capacity is general in nature, and can be applied to designing efficient hydrogen storage systems. Following this strategy, a search for the best metallacarborane was carried out in which Sc based monocarborane was found to be the most promising H{sub 2} sorbent material with a 9 wt.% of reversible storage at ambient pressure and temperature.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗