Search NASA⌕ Search

SEARCH · Search NASA

Results for “Signal Detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,009 records · Page 56

Lightning Flash Detection System (LFDS) [Poster]

The Electromagnetics Group wanted another system for detecting lightning flashes near/around the Pantex Plant. The current system in use detects lightning by detecting RF signals at a particular frequency. LFDS detects lightning by detecting flashes of light in the visual and near IR spectrums. This work is primarily focused on detecting cloud-to-ground lightning.

42 ENGINEERING↗

Ground-Sensing Circuit For Arc Welders

Ground-sensing circuit for arc-welding power supply prevents arc burns at loose ground connections on workpiece. Used with ac supply or dc supply of either polarity. Includes oscillator/detector pairs normally shorted out by ground connections to workpiece. When one or more of these four connections broken, one or more oscillator signals applied across power diodes and detected. Detected oscillator signal trips shutoff relay.

Burley, Richard K.↗

Zero-power receiver

An unpowered signal receiver and a method for signal reception detects and responds to very weak signals using pyroelectric devices as impedance transformers and/or demodulators. In some embodiments, surface acoustic wave devices (SAW) are also used. Illustrative embodiments include satellite and long distance terrestrial communications applications.

47 OTHER INSTRUMENTATION↗

Radio frequency interference at Jodrell Bank Observatory within the protected 21 cm band

Radio frequency interference (RFI) will provide one of the most difficult challenges to systematic Searches for Extraterrestrial Intelligence (SETI) at microwave frequencies. The SETI-specific equipment is being optimized for the detection of signals generated by a technology rather than those generated by natural processes in the universe. If this equipment performs as expected, then it will inevitably detect many signals originating from terrestrial technology. If these terrestrial signals are too numerous and/or strong, the equipment will effectively be blinded to the (presumably) weaker extraterrestrial signals being sought. It is very difficult to assess how much of a problem RFI will actually represent to future observations, without employing the equipment and beginning the search. In 1983 a very high resolution spectrometer was placed at the Nuffield Radio Astronomy Laboratories at Jodrell Bank, England. This equipment permitted an investigation of the interference environment at Jodrell Bank, at that epoch, and at frequencies within the 21 cm band. This band was chosen because it has long been "protected" by international agreement; no transmitters should have been operating at those frequencies. The data collected at Jodrell Bank were expected to serve as a "best case" interference scenario and provide the minimum design requirements for SETI equipment that must function in the real and noisy environment. This paper describes the data collection and analysis along with some preliminary conclusions concerning the nature of the interference environment at Jodrell Bank.

NASA Discipline Number 52-60↗

Optimum Detection of Frequency-Hopped Signals

This paper derives and analyzes optimum and near-optimum structures for detecting frequency-hopped (FH) signals with arbitrary modulation in additive white Gaussian noise. The principalmodulation formats considered are M-ary frequency-shift-keying (MFSK) with fast frequency hopping(FFH) wherein a single tone is transmitted per hop, and slow frequency hopping (SFH) with multipleMFSK tones (data symbols) per hop. The SFH detection category has not previously been addressedin the open literature and its analysis is generally more complex than FFH.

Cheng, Unjeng↗

Analysis of SETI data collected in the parasitic mode

A system for performing SETI observations continuously as part of non-SETI observations at a radio observatory is presented, and the analysis of results obtained by the parasitic system is discussed. The system, designated SERENDIP, is a real-time microprocessor-controlled spectrum analyzer with algorithms for performing statistical operations and recording those spectra with characteristics presumed to be typical of intelligent rather than astrophysical origin. Programs also exist for the post-acquisition analysis of signal autocorrelation, power spectra, time behavior and positional coordinates, and for a generalized cluster analysis to detect clusters of signal detections. In a recent run of 35 days, the SERENDIP system detected 4000 narrowband spectra exceeding a preset threshold, of which 98% were determined to be of instrumental origin. The remaining class of detections is also believed to be instrumental, although not as well organized as the first signals, and means are currently being sought for eliminating them.

Bowyer, S.↗

Effect of the Temperature-Emissivity Contrast on the Chemical Signal for Gas Plume Detection Using Thermal Image Data

Detecting and identifying weak gaseous plumes using thermal imaging data is complicated by many factors. These include variability due to atmosphere, ground and plume temperature, and background clutter. This paper presents an analysis of one formulation of the physics-based radiance model, which describes at-sensor observed radiance. The background emissivity and plume/ground temperatures are isolated, and their effects on net chemical signal are described. This analysis shows that the plume’s physical state, emission or absorption, is directly dependent on that background emissivity. It then describes what conditions on the background emissivity have inhibiting effects on the net chemical signal. These claims are illustrated by analyzing synthetic hyperspectral imaging data with the Adaptive Matched Filter using two chemicals and three distinct background emissivities.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Optical Design and Signal Processing for Edge Detection

Properly combining optical design with 3-by-3 element mask reduces number of required computations by factor of as much as 100. Spatial and spatial-frequency responses obtained in system of combination of optical design and signal-processing algorithm. Closely approximate difference-of-Gaussian-function response.

Huck, Friedrich O.↗

Analysis and improved design considerations for airborne pulse Doppler radar signal processing in the detection of hazardous windshear

High resolution windspeed profile measurements are needed to provide reliable detection of hazardous low altitude windshear with an airborne pulse Doppler radar. The system phase noise in a Doppler weather radar may degrade the spectrum moment estimation quality and the clutter cancellation capability which are important in windshear detection. Also the bias due to weather return Doppler spectrum skewness may cause large errors in pulse pair spectral parameter estimates. These effects are analyzed for the improvement of an airborne Doppler weather radar signal processing design. A method is presented for the direct measurement of windspeed gradient using low pulse repetition frequency (PRF) radar. This spatial gradient is essential in obtaining the windshear hazard index. As an alternative, the modified Prony method is suggested as a spectrum mode estimator for both the clutter and weather signal. Estimation of Doppler spectrum modes may provide the desired windshear hazard information without the need of any preliminary processing requirement such as clutter filtering. The results obtained by processing a NASA simulation model output support consideration of mode identification as one component of a windshear detection algorithm.

Lee, Jonggil↗

Detection of Artificially Generated Seismic Signals Using Balloon-Borne Infrasound Sensors

Here, we conducted an experiment in Pahrump, Nevada, in June 2017, where artificial seismic signals were created using a seismic hammer, and the possibility of detecting them from their acoustic signature was examined. In this work, we analyze the pressure signals recorded by highly sensitive barometers deployed on the ground and on tethers suspended from balloons. Our signal processing results show that wind noise experienced by a barometer on a free-flying balloon is lower compared to one on a moored balloon. This has never been experimentally demonstrated in the lower troposphere. While seismoacoustic signals were not recorded on the hot air balloon platform owing to operational challenges, we demonstrate the detection of seismoacoustic signals on our moored balloon platform. Our results have important implications for performing seismology in harsh surface environments such as Venus through atmospheric remote sensing.

58 GEOSCIENCES↗

FERMI LARGE AREA TELESCOPE OBSERVATION OF A GAMMA-RAY SOURCE AT THE POSITION OF ETA CARINAE

The Large Area Telescope (LAT) on board the Fermi Gamma-ray Space Telescope detected a {gamma}-ray source that is spatially consistent with the location of Eta Carinae. This source has been persistently bright since the beginning of the LAT survey observations (from 2008 August to 2009 July, the time interval considered here). The {gamma}-ray signal is detected significantly throughout the LAT energy band (i.e., up to {approx}100 GeV). The 0.1-100 GeV energy spectrum is well represented by a combination of a cutoff power-law model (<10 GeV) and a hard power-law component (>10 GeV). The total flux (>100 MeV) is 3.7{sup +0.3}{sub -0.1} x 10{sup -7} photons s{sup -1} cm{sup -2}, with additional systematic uncertainties of 10%, and consistent with the average flux measured by AGILE. The light curve obtained by Fermi is consistent with steady emission. Our observations do not confirm the presence of a {gamma}-ray flare in 2008 October, as reported by Tavani et al., although we cannot exclude that a flare lasting only a few hours escaped detection by the Fermi LAT. We also do not find any evidence for {gamma}-ray variability that correlates with the large X-ray variability of Eta Carinae observed during 2008 December and 2009 January. We are thus not able to establish an unambiguous identification of the LAT source with Eta Carinae.

79 ASTRONOMY AND ASTROPHYSICS↗

Real-Time Analysis and Signal Optimization for Charge Detection Mass Spectrometry

Charge detection mass spectrometry (CDMS) is an important tool for measuring mass distributions for high mass samples and heterogeneous mixtures. In CDMS, single ions are trapped and their m/z and charge are measured simultaneously. As a single particle technique, the average signal must be optimized to maximize the number of single ion trapping events. If the average signal is too small, most of the trapping events will be empty, and if the average signal is too large, most of the trapping events will contain multiple ions. In recent embodiments, the time domain signal from the trapped ion is analyzed by fast Fourier transforms. The analysis time is much longer that the data collection time which precludes real-time optimization of the experimental conditions. In this paper, we describe the implementation of CDMS with real-time analysis. Processing the data in real time allows the average signal intensities to be dynamically optimized to maximize the number of single ion trapping events. Real-time analysis also allows the experimental settings to be optimized in a timely manner to target specific mass regimes to maximize the useful information content of the measurements. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Electronic properties of Si hollow nanowires

The electronic and structural properties of amorphous and crystalline silicon hollow nanowires (HNWs) have been investigated by X-ray photoemission (XPS), Raman, and photoluminescence spectroscopies. The HNWs have an internal diameter of about 80 nm and sidewalls with a thickness of 8–15 nm. Crystalline HNWs are obtained by thermal annealing of the amorphous ones. XPS shows that although oxidation is a very important process in these suspended nanostructures, a clear Si 2p signal is detected in the crystalline HNWS, thus indicating that the sidewall surface maintains mainly a pure silicon nature. Raman shows that the thermal annealing gives rise to a very good crystal quality and a weak visible luminescence signal is detected in the crystalline HNWs.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Detectability of the Reflection Signal from Inner Planets

Mayor and Queloz (1996) and Marcy and Butler (1996) have found massive planets with orbital periods Tp=approx.4 days around two solar-like stars (51 Pegasi and v Andromeda). These planets are most likely similar in size and composition to the gas giants in our solar system (Burrows et al 1996). Based on this expectation and assuming the same albedo as Jupiter, we examined the feasibility of searching for similar planets with a dedicated space-based 1-m telescope. The Kepler mission will survey approximately 70,000 main-sequence dwarf stars from 9 to 14 mag continuously for four years to detect transiting Earthlike planets. Based on the detection statistics of Marcy and Butler, we expect to detect 1400 inner-orbit giant planets. Such planets in a much wider range of orbital inclinations (i) will produce nearly sinusoidal modulations of the star light flux due to the varying planetary phases. The relative signal amplitudes are of order 2x10(exp -5) and decrease as Tp(exp 4/3) for i >> 0deg. We estimated the expected signal to noise ratio (SNR) using the solar irradiance measurements from the ACRIM 1 experiment along with expected shot and detector noises. The figure shows SNR as a function of Tp for a 12 mag star, and indicates the planet radius required for detection. The survey will be sensitive to planets with periods from 12 hr to approx.8 days at the 6 sigma level.

Borucki, W. J.↗

HD 202772A b: A Transiting Hot Jupiter around a Bright, Mildly Evolved Star in a Visual Binary Discovered by TESS

We report the first confirmation of a hot Jupiter discovered by the Transiting Exoplanet Survey Satellite (TESS) mission: HD 202772A b. The transit signal was detected in the data from TESS Sector 1, and was confirmed to be of planetary origin through radial velocity (RV) measurements. HD 202772A b is orbiting a mildly evolved star with a period of 3.3 days. With an apparent magnitude of V = 8.3, the star is among the brightest and most massive known to host a hot Jupiter. Based on the 27 days of TESS photometry and RV data from the CHIRON, HARPS, and Tillinghast Reflector Echelle Spectrograph, the planet has a mass of 1.017{sub −0.068}{sup +0.070} M{sub J} and radius of 1.545{sub −0.060}{sup +0.052} R{sub J}, making it an inflated gas giant. HD 202772A b is a rare example of a transiting hot Jupiter around a quickly evolving star. It is also one of the most strongly irradiated hot Jupiters currently known.

79 ASTRONOMY AND ASTROPHYSICS↗

Ambient ion focusing from a field-free region to a detector: enhanced signal for explosives and drug detection with mass spectrometry

This study demonstrates ion focusing at ambient pressure and increased ion signal by creating a voltage gradient from a field-free region to a detector, thereby improving the detection of chemicals, such as explosives and drugs. At ambient pressure, ion loss and resulting signal reduction pose challenges that limit detection sensitivity in analytical instruments. Techniques to increase sensitivity, such as atmospheric flow tube-mass spectrometry (AFT-MS), extend ion-molecule reaction times but result in significant overall ion loss due to diffusion. Ion manipulation techniques, though challenging at ambient pressure, can mitigate these losses by concentrating ions toward the detector inlet. Using SIMION, ion trajectories were modeled with a voltage gradient applied between a flow tube and a detector, revealing ion focusing at ambient pressure. Experimental verification with an atmospheric flow tube employed both mass spectrometry and Faraday plate detectors to measure ion beam profiles across varying flow rates, tube diameters, and voltage gradients. Application of a voltage gradient effectively directed ions to the axial center of the flow tube, narrowed ion beam width, and increased signal intensity by 5 to 10 times compared to conditions without a voltage gradient. This ion focusing approach shows promise for improving sensitivity in ambient-pressure instruments. This technique has the potential to enhance detection levels in security and forensic applications, with particular benefits for field-portable devices used at checkpoints to identify explosives and drugs.

ambient pressure↗