Search NASA⌕ Search

SEARCH · Search NASA

Results for “Standard deviation modeling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,009 records · Page 56

PROSPECT: A Precision Reactor Oscillation and Spectrum Experiment

Nuclear reactors are a source of copious amounts of electron antineutrinos. They are emitted in the beta decays of the fission products and their energies depend on the isotopic composition of the reactor. In recent years a number of reactor antineutrino experiments including Daya Bay, Double Chooz, and RENO reported a deficit in the measured flux of antineutrinos from reactors compared to expectation and a spectral deviation in the measured energy spectra compared to model predictions. These observations led to the hypothesis of sterile neutrino oscillation as an explanation of the flux deficit. New physics or incomplete nuclear models may explain the origin of the spectral deviation. PROSPECT, the Precision Reactor Oscillation and Spectrum Experiment, is a novel neutrino experiment at the High Flux Isotope Reactor (HFIR) at Oak Ridge National Laboratory (ORNL) designed to address two major scientific objectives: 1. Perform a search for eV-scale sterile neutrinos independent of reactor neutrino models by searching for the oscillation signature of massive, sterile neutrino states beyond the 3 known active neutrino species. The discovery of sterile neutrinos would indicate a new form of matter and require physics beyond the Standard Model. 2. Perform the first modern precision measurement of the antineutrino spectrum from a Highly Enriched Uranium (HEU) 235 U reactor to benchmark our understanding of the neutrino emission from nuclear reactors and to understand the isotopic origin of spectral deviations observed in previous reactor neutrino experiments.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Lamb shift in muonic hydrogen-II. Analysis of the discrepancy of theory and experiment

Research Highlights: > Various theoretical explanation for the recently observed experimental-theoretical discrepancy in the muonic hydrogen Lamb shift are explored. > These include a dip in the proton form factor slope, nonperturbative vacuum polarization and millicharged virtual particles, as well as process-dependent screening corrections. > Screening corrections may need to be explored further. > The need for an alternative determination of the Rydberg constant is highlighted. - Abstract: Currently, both the g factor measurement of the muon as well as the Lamb shift 2S-2P measurement in muonic hydrogen are in disagreement with theory. Here, we investigate possible theoretical explanations, including proton structure effects and small modifications of the vacuum polarization potential. In particular, we investigate a conceivable small modification of the spectral function of vacuum polarization in between the electron and muon energy scales due to a virtual millicharged particle and due to an unstable vector boson originating from a hidden sector of an extended standard model. We find that a virtual millicharged particle which could explain the muonic Lamb shift discrepancy alters theoretical predictions for the muon anomalous magnetic moment by many standard deviations and therefore is in conflict with experiment. Also, we find no parameterizations of an unstable virtual vector boson which could simultaneously explain both 'muonic' discrepancies without significantly altering theoretical predictions for electronic hydrogen, where theory and experiment currently are in excellent agreement. A process-dependent correction involving electron screening is evaluated to have the right sign and order-of-magnitude to explain the observed effect in muonic hydrogen. Additional experimental evidence from light muonic atoms and ions is needed in order to reach further clarification.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Study of grain structure evolution during annealing of a twin-roll-cast Mg alloy

The evolution of microstructure under static annealing was studied for mid-thickness section of a twin-roll-cast (TRC) magnesium alloy. Annealing was performed at 300 °C and 500 °C for different times. Microstructural evolution was quantitatively analyzed, from optical micrographs, using grain path envelope analysis. Additional information from electron backscatter diffraction (EBSD) was used for addressing the possible mechanism(s). It was found that the TRC structure had a bimodal grain size, which was preserved even after annealing at 300 °C. However, the annealing at 500 °C led to a unimodal grain size. This difference in the grain size distribution created a contrasting behavior in the normalized standard deviations. This was primarily attributed to a competition between recovery and recrystallization, and their respective dominance at 300° and 500 °C. A deformation induced recrystallization recovery (DIRR) model was proposed. The proposed model could successfully address the experimental microstructural evolution. - Highlights: • Annealing of twin roll cast (TRC) magnesium alloy was done at temperatures of 300 °C and 500 °C. • TRC had bimodal structure. Bimodality preserved for annealing at 300 °C. Annealing at 500 °C led to unimodal structure. • Grain evolution was described based on the competition between recovery and recrystallization. • Deformation induced recrystallization recovery (DIRR) mechanistic model was developed.

36 MATERIALS SCIENCE↗

Observation of electroweak W + W – pair production in association with two jets in proton-proton collisions at √s = 13 TeV

An observation is reported of the electroweak production of a W + W – pair in association with two jets, with both W bosons decaying leptonically. The data sample corresponds to an integrated luminosity of 138 fb –1 of proton-proton collisions at √s = 13 TeV, collected by the CMS detector at the CERN LHC. Events are selected by requiring exactly two opposite-sign leptons (electrons or muons) and two jets with large pseudorapidity separation and high dijet invariant mass. Events are categorized based on the flavor of the final-state leptons. A signal is observed with a significance of 5.6 standard deviations (5.2 expected) with respect to the background-only hypothesis. The measured fiducial cross section is 10.2 ± 2.0 fb and this value is consistent with the standard model prediction of 9.1 ± 0.6 fb.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Upgrading Limiting Peak-Power Analysis Techniques with Modern Validation and Uncertainty Quantification for the Advanced Test Reactor

Here, this work demonstrates the acceptability of the 2D deterministic transport code, HELIOS, to replace the legacy diffusion code, PDQ, for computing the peak-power performance parameters of the Advanced Test Reactor (ATR). The 95% Confidence Rule, commonly used in the commercial reactor sector, is explored to develop the so-called “reliability factors” which provide statistical confidence that the peak-power limits within the hottest location along a fuel plate, referred to as the hot-stripe, will not be exceeded. Additionally, an alternative “legacy” methodology was explored that attempts to mimic the exact PDQ analysis process used for defining the peak-power limits. The legacy methodology, involves interpolating power between regions at azimuthal boundaries subtending the regions of interest. In order to apply the 95% Confidence Rule, a statistically significant calculation-to-measurement bias must first be established. Unlike the commercial world where thousands of power observations can be collected every cycle using on-line flux mapping instrumentation, the ATR power distribution must be measured during “depressurized” zero-power measurements using fission wires in polyethylene wands. In 2012, fission wire activation data was collected during a flux run in the Advanced Test Reactor – Critical facility. Also to improve statistical validity, archival data from ATR zero power flux runs from 1977, 1986, and 1994 were digitized from scanned reports and used to create new benchmark models. Borrowing from least-squares adjustment methods commonly used for neutron activation spectroscopy, adjusted fission wire powers were calculated for all four datasets. The mean and standard deviation of the bias between a priori calculated and adjusted wire-powers was then taken as the bias and uncertainty used in the 95% Confidence Rule.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Constraining early and interacting dark energy with gravitational wave standard sirens: the potential of the eLISA mission

We perform a forecast analysis of the capability of the eLISA space-based interferometer to constrain models of early and interacting dark energy using gravitational wave standard sirens. We employ simulated catalogues of standard sirens given by merging massive black hole binaries visible by eLISA, with an electromagnetic counterpart detectable by future telescopes. We consider three-arms mission designs with arm length of 1, 2 and 5 million km, 5 years of mission duration and the best-level low frequency noise as recently tested by the LISA Pathfinder. Standard sirens with eLISA give access to an intermediate range of redshift 1 ∼< z ∼< 8, and can therefore provide competitive constraints on models where the onset of the deviation from ΛCDM (i.e. the epoch when early dark energy starts to be non-negligible, or when the interaction with dark matter begins) occurs relatively late, at z ∼< 6. If instead early or interacting dark energy is relevant already in the pre-recombination era, current cosmological probes (especially the cosmic microwave background) are more efficient than eLISA in constraining these models, except possibly in the interacting dark energy model if the energy exchange is proportional to the energy density of dark energy.

79 ASTRONOMY AND ASTROPHYSICS↗

Interfraction patient motion and implant displacement in prostate high dose rate brachytherapy

Purpose: To quantify movement of prostate cancer patients undergoing treatment, using an in-house developed motion sensor in order to determine a relationship between patient movement and high dose rate (HDR) brachytherapy implant displacement. Methods: An electronic motion sensor was developed based on a three axis accelerometer. HDR brachytherapy treatment for prostate is delivered at this institution in two fractions 24 h apart and 22 patients were monitored for movement over the interval between fractions. The motion sensors functioned as inclinometers, monitoring inclination of both thighs, and the inclination and roll of the abdomen. The implanted HDR brachytherapy catheter set was assessed for displacement relative to fiducial markers in the prostate. Angle measurements and angle differences over a 2 s time base were binned, and the standard deviations of the resulting frequency distributions used as a metric for patient motion in each monitored axis. These parameters were correlated to measured catheter displacement using regression modeling. Results: The mean implant displacement was 12.6 mm in the caudal direction. A mean of 19.95 h data was recorded for the patient cohort. Patients generally moved through a limited range of angles with a mean of the exception of two patients who spent in excess of 2 h lying on their side. When tested for a relationship between movement in any of the four monitored axes and the implant displacement, none was significant. Conclusions: It is not likely that patient movement influences HDR prostate implant displacement. There may be benefits to patient comfort if nursing protocols were relaxed to allow patients greater freedom to move while the implant is in situ.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-J-67: Evaluation of Breathing Patterns for Respiratory-Gated Radiation Therapy Using Respiration Regularity Index

Purpose: Despite the importance of accurately estimating the respiration regularity of a patient in motion compensation treatment, an effective and simply applicable method has rarely been reported. The authors propose a simple respiration regularity index based on parameters derived from a correspondingly simplified respiration model. Methods: In order to simplify a patient's breathing pattern while preserving the data's intrinsic properties, we defined a respiration model as a power of cosine form with a baseline drift. According to this respiration formula, breathing-pattern fluctuation could be explained using four factors: sample standard deviation of respiration period, sample standard deviation of amplitude and the results of simple regression of the baseline drift (slope and standard deviation of residuals of a respiration signal. Overall irregularity (δ) was defined as a Euclidean norm of newly derived variable using principal component analysis (PCA) for the four fluctuation parameters. Finally, the proposed respiration regularity index was defined as ρ=ln(1+(1/ δ))/2, a higher ρ indicating a more regular breathing pattern. Subsequently, we applied it to simulated and clinical respiration signals from real-time position management (RPM; Varian Medical Systems, Palo Alto, CA) and investigated respiration regularity. Moreover, correlations between the regularity of the first session and the remaining fractions were investigated using Pearson's correlation coefficient. Results: The respiration regularity was determined based on ρ; patients with ρ<0.3 showed worse regularity than the others, whereas ρ>0.7 was suitable for respiratory-gated radiation therapy (RGRT). Fluctuations in breathing cycle and amplitude were especially determinative of ρ. If the respiration regularity of a patient's first session was known, it could be estimated through subsequent sessions. Conclusions: Respiration regularity could be objectively determined using a respiration regularity index, ρ. Such single-index testing of respiration regularity can facilitate determination of RGRT availability in clinical settings, especially for free-breathing cases. This work was supported by a Korea Science and Engineering Foundation (KOSEF) grant funded by the Korean Ministry of Science, ICT and Future Planning (No. 2013043498)

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Search for new physics in events with a leptonically decaying Z boson and a large transverse momentum imbalance in proton–proton collisions at $\sqrt{s} $ = 13 $\,\text {TeV}$

A search for new physics in events with a Z boson produced in association with large missing transverse momentum at the LHC is presented. The search is based on the 2016 data sample of proton-proton collisions recorded with the CMS experiment at $\sqrt{s} = 13\,\text {TeV} $ , corresponding to an integrated luminosity of 35.9 $\,\text {fb}^{-1}$ . The results of this search are interpreted in terms of a simplified model of dark matter production via spin-0 or spin-1 mediators, a scenario with a standard-model-like Higgs boson produced in association with the Z boson and decaying invisibly, a model of unparticle production, and a model with large extra spatial dimensions. No significant deviations from the background expectations are found, and limits are set on relevant model parameters, significantly extending the results previously achieved in this channel.

43 PARTICLE ACCELERATORS↗

Measurement of ${\mathcal B}(B^0_s\rightarrow D_s^{(*)}D_s^{(*)})$ > and the Lifetime Difference in the $B_s^0$ System

We search for the semi-inclusive process $B^0_s\rightarrow D_s^{(*)}D_s^{(*)}$ using 2.8 fb$^{-1}$ of $p \bar{p}$ collisions at $\sqrt{s} = 1.96$ TeV recorded by the D0 detector operating at the Fermilab Tevatron Collider. Under certain theoretical assumptions, these double-charm final states saturate CP-even eigenstates in the $B_s^0$ decays, allowing the lifetime difference of the $B_s^0$ system to be related to the branching ratio. We observe $26.6\pm 8.4$ signal events with a significance above background of 3.2 standard deviations. The branching ratio is measured as ${\cal B}(B^0_s\rightarrow D_s^{(*)}D_s^{(*)}) = 0.035\pm0.010\text{(stat)}\pm0.011\text{(syst)}$ and, in the Standard Model, the width difference is derived as $\Delta \Gamma_s^{\rm CP}/\Gamma_s = 0.072\pm0.021\text{(stat)}\pm0.022\text{(syst)}$.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Nitrogen Cycle Dynamics Revealed Through δ 18 O-NO 3 - Analysis in California Groundwater

Nitrate is a significant water-quality issue in California, the United States as a whole, and the world. Critical to addressing nitrate contamination is understanding the presence and extent of denitrification, and further refining the techniques used to identify nitrate sources. The use and understanding of nitrate isotopic signatures to identify nitrate sources have advanced tremendously; however, knowledge gaps remain concerning specific fractionation pathways and the role of denitrification in altering source values. Using a large unique database of California groundwater nitrate isotopic compositions, we explored the utility of nitrate–oxygen isotope ratios in determining specific nitrate origins. Lawrence Livermore National Lab (LLNL) samples were supplemented by United States Geological Society (USGS) data to create a dataset of over 1200 dual-isotope results. Methods used at LLNL allowed for the determination of δ 15 N-NO 3 -, δ 18 O-NO 3 -, δ 18 O-H 2 O, δ 2 H-H 2 O, excess air, major dissolved gases, and excess N 2 . Results were examined for the degree to which δ 18 O-NO 3 - conforms to the model of nitrification in which two atoms of oxygen are sourced from ambient water and one from the atmosphere. Almost 80% of the results fall within one standard deviation of predicted values. However, 19% of samples had significantly higher values, suggesting the preservation of a synthetic nitrate source signature, mixing of sources, or widespread denitrification. Results were examined with respect to general land-use classifications and, while nitrate concentrations followed the expected pattern of being higher in agricultural settings, δ 18 O-NO 3 -patterns are complicated by application of N-fertilizer in various forms, and subsequent N cycling in the soil zone. We found that the current understanding of oxygen isotope-fractionation mechanisms cannot yet explain the prevalence of oxygen-isotope compositions with higher than predicted δ 18 O values, but when paired with related data such as land use and indicators of denitrification, oxygen-isotope compositions of nitrate can help to assess nitrogen cycle dynamics.

54 ENVIRONMENTAL SCIENCES↗

Indirect searches at CMS

In these proceedings, we present several new measurements of Standard Model (SM) processes, in the Higgs sector and beyond, that push the precision frontier forward at CMS. Results are presented in the context of a framework parameterizing deviations in Higgs boson couplings, as well as in the context of SM Effective Field Theory, where new analyses targeting Higgs, top, and multi-boson processes probe an increasingly diverse set of operators. Within these frameworks, CMS is efficiently exploring a large space of new physics models. No significant deviation from SM expectations is found.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A voxel-based finite element model for the prediction of bladder deformation

Purpose: A finite element (FE) bladder model was previously developed to predict bladder deformation caused by bladder filling change. However, two factors prevent a wide application of FE models: (1) the labor required to construct a FE model with high quality mesh and (2) long computation time needed to construct the FE model and solve the FE equations. In this work, we address these issues by constructing a low-resolution voxel-based FE bladder model directly from the binary segmentation images and compare the accuracy and computational efficiency of the voxel-based model used to simulate bladder deformation with those of a classical FE model with a tetrahedral mesh. Methods: For ten healthy volunteers, a series of MRI scans of the pelvic region was recorded at regular intervals of 10 min over 1 h. For this series of scans, the bladder volume gradually increased while rectal volume remained constant. All pelvic structures were defined from a reference image for each volunteer, including bladder wall, small bowel, prostate (male), uterus (female), rectum, pelvic bone, spine, and the rest of the body. Four separate FE models were constructed from these structures: one with a tetrahedral mesh (used in previous study), one with a uniform hexahedral mesh, one with a nonuniform hexahedral mesh, and one with a low-resolution nonuniform hexahedral mesh. Appropriate material properties were assigned to all structures and uniform pressure was applied to the inner bladder wall to simulate bladder deformation from urine inflow. Performance of the hexahedral meshes was evaluated against the performance of the standard tetrahedral mesh by comparing the accuracy of bladder shape prediction and computational efficiency. Results: FE model with a hexahedral mesh can be quickly and automatically constructed. No substantial differences were observed between the simulation results of the tetrahedral mesh and hexahedral meshes (<1% difference in mean dice similarity coefficient to manual contours and <0.02 cm difference in mean standard deviation of residual errors). The average equation solving time (without manual intervention) for the first two types of hexahedral meshes increased to 2.3 h and 2.6 h compared to the 1.1 h needed for the tetrahedral mesh, however, the low-resolution nonuniform hexahedral mesh dramatically decreased the equation solving time to 3 min without reducing accuracy. Conclusions: Voxel-based mesh generation allows fast, automatic, and robust creation of finite element bladder models directly from binary segmentation images without user intervention. Even the low-resolution voxel-based hexahedral mesh yields comparable accuracy in bladder shape prediction and more than 20 times faster in computational speed compared to the tetrahedral mesh. This approach makes it more feasible and accessible to apply FE method to model bladder deformation in adaptive radiotherapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Recommended Pasquill-Gifford Stability Classification Method for Safety Basis Atmospheric Dispersion Modeling at SRS

Several of the most common methods for estimating Pasquill-Gifford (PG) stability (turbulence) class were evaluated for use in modeling the radiological consequences of SRS accidental releases using the MELCOR Accident Consequence Code System, Ver. 2 (MACCS2). Evaluation criteria included: (1) the ability of the method to represent diffusion characteristics above a predominantly forested landscape at SRS, (2) suitability of the method to provide data consistent with the formulation of the MACCS2 model, and (3) the availability of onsite meteorological data to support implementation of the method The evaluation resulted in a recommendation that PG stability classification for regulatory applications at SRS should be based on measurements of the standard deviation of the vertical component of wind direction fluctuations, σ e , collected from the 61-m level of the SRS meteorological towers, and processed in full accordance with EPA-454/R-99-005 (EPA, 2000). This approach provides a direct measurement that is fundamental to diffusion and captures explicitly the turbulence generated by both mechanical and buoyant forces over the characteristic surface (forested) of SRS. Furthermore, due to the potentially significant enhancement of horizontal fluctuations in wind direction from the occurrence of meander at night, the use of σ e will ensure a reasonably conservative estimate of PG stability class for use in dispersion models that base diffusion calculations on a single value of PG stability class. Furthermore, meteorological data bases used as input for MACCS2 calculations should contain hourly data for five consecutive annual periods from the most recent 10 years.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Planck 2013 results. XV. CMB power spectra and likelihood

This paper presents the Planck 2013 likelihood, a complete statistical description of the two-point correlation function of the CMB temperature fluctuations that accounts for all known relevant uncertainties, both instrumental and astrophysical in nature. We use this likelihood to derive our best estimate of the CMB angular power spectrum from Planck over three decades in multipole moment, &ell;, covering 2 &le; &ell; &le; 2500. The main source of uncertainty at &ell; &le; 1500 is cosmic variance. Uncertainties in small-scale foreground modelling and instrumental noise dominate the error budget at higher &ell;s. For &ell; < 50, our likelihood exploits all Planck frequency channels from 30 to 353 GHz, separating the cosmological CMB signal from diffuse Galactic foregrounds through a physically motivated Bayesian component separation technique. At &ell; &le; 50, we employ a correlated Gaussian likelihood approximation based on a fine-grained set of angular cross-spectra derived from multiple detector combinations between the 100, 143, and 217 GHz frequency channels, marginalising over power spectrum foreground templates. We validate our likelihood through an extensive suite of consistency tests, and assess the impact of residual foreground and instrumental uncertainties on the final cosmological parameters. We find good internal agreement among the high-&ell; cross-spectra with residuals below a few &mu;K 2 at &ell; ≲ 1000, in agreement with estimated calibration uncertainties. We compare our results with foreground-cleaned CMB maps derived from all Planck frequencies, as well as with cross-spectra derived from the 70 GHz Planck map, and find broad agreement in terms of spectrum residuals and cosmological parameters. We further show that the best-fit CDM cosmology is in excellent agreement with preliminary Planck EE and TE polarisation spectra. We find that the standard ΛCDM cosmology is well constrained by Planck from the measurements at &ell; ≲ 1500. One specific example is the spectral index of scalar perturbations, for which we report a 5.4σ deviation from scale invariance, n s = 1. Increasing the multipole range beyond &ell; ≃ 1500 does not increase our accuracy for the ΛCDM parameters, but instead allows us to study extensions beyond the standard model. We find no indication of significant departures from the ΛCDM framework. Finally, we report a tension between the Planck best-fit ΛCDM model and the low-&ell; spectrum in the form of a power deficit of 5&ndash;10% at &ell; ≲ 40, with a statistical significance of 2.5&ndash;3σ. Without a theoretically motivated model for this power deficit, we do not elaborate further on its cosmological implications, but note that this is our most puzzling finding in an otherwise remarkably consistent data set.

79 ASTRONOMY AND ASTROPHYSICS↗

Observation of a new boson with mass near 125 GeV in pp collisions at $ \sqrt{s}=7 $ and 8 TeV

A detailed description is reported of the analysis used by the CMS Collaboration in the search for the standard model Higgs boson in pp collisions at the LHC, which led to the observation of a new boson. The data sample corresponds to integrated luminosities up to 5.1 inverse femtobarns at $\sqrt{s}$ = 7 TeV, and up to 5.3 inverse femtobarns at $\sqrt{s}$ = 8 TeV. The results for five Higgs boson decay modes $\gamma\gamma, ZZ, WW, \tau \tau$, and bb, which show a combined local significance of 5 standard deviations near 125 GeV, are reviewed. A fit to the invariant mass of the two high resolution channels, gamma gamma and ZZ to 4 ell, gives a mass estimate of 125.3 +/- 0.4 (stat) +/- 0.5 (syst) GeV. The measurements are interpreted in the context of the standard model Lagrangian for the scalar Higgs field interacting with fermions and vector bosons. The measured values of the corresponding couplings are compared to the standard model predictions. The hypothesis of custodial symmetry is tested through the measurement of the ratio of the couplings to the W and Z bosons. All the results are consistent, within their uncertainties, with the expectations for a standard model Higgs boson.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A Process‐Model Perspective on Recent Changes in the Carbon Cycle of North America

Continental North America has been found to be a carbon (C) sink over recent decades by multiple studies employing a variety of estimation approaches. However, several key questions and uncertainties remain with these assessments. Here we used results from an ensemble of 19 state-of-the-art dynamic global vegetation models from the TRENDYv9 project to improve these estimates and study the drivers of its interannual variability. Our results show that North America has been a C sink with a magnitude of 0.37 ± 0.38 (mean and one standard deviation) PgC year —1 for the period 2000–2019 (0.31 and 0.44 PgC year —1 in each decade); split into 0.18 ± 0.12 PgC year —1 in Canada (0.15 and 0.20), 0.16 ± 0.17 in the United States (0.14 and 0.17), 0.02 ± 0.05 PgC year —1 in Mexico (0.02 and 0.02) and 0.01 ± 0.02 in Central America and the Caribbean (0.01 and 0.01). About 57% of the new C assimilated by terrestrial ecosystems is allocated into vegetation, 30% into soils, and 13% into litter. Losses of C due to fire account for 41% of the interannual variability of the mean net biome productivity for all North America in the model ensemble. Finally, we show that drought years (e.g., 2002) have the potential to shift the region to a small net C source in the simulations (—0.02 ± 0.46 PgC year —1 ). Our results highlight the importance of identifying the major drivers of the interannual variability of the continental-scale land C cycle along with the spatial distribution of local sink-source dynamics.

54 ENVIRONMENTAL SCIENCES↗

Optimization of a dual-energy contrast-enhanced technique for a photon-counting digital breast tomosynthesis system: II. An experimental validation

Purpose: Previously, the authors developed a dual-energy (DE) acquisition technique for a photon-counting digital breast tomosynthesis (DBT) imaging system. Low-energy (LE) and high-energy (HE) images are acquired in a single scan by covering alternate slits of a multislit prepatient collimator with Sn and Cu, respectively. A theoretical model was used to optimize the technique. In this article, an experimental validation of this technique is presented. Methods: Experiments were performed on a prototype DBT system. LE and HE projection images were acquired sequentially; either a Sn or a Cu filter was positioned in the filter holder at the exit window of the x-ray tube. Sn filters from 0.113 to 0.242 mm thick and Cu filters from 0.103 to 0.267 mm were used. The images were acquired with a W target at 49 kV. Tomographic images, hereafter referred to as DBT images, were reconstructed using a shift-and-add algorithm. DE-DBT images were obtained by weighted logarithmic subtraction of the LE and HE images. Weighting factors w{sub t} that optimally cancel breast tissues with two different glandularities were assessed for 20-80 mm thick phantoms with 0%, 50%, and 100% glandularity. The mean and standard deviation in the per-pixel signal intensity (SI) were calculated in the DBT images. These data were used to calculate signal-difference-to-noise ratios (SDNRs) between iodine enhanced and nonenhanced polymethyl methacrylate backgrounds. To illustrate the feasibility of the technique, DE-DBT images of a structured phantom containing iodine disks were assessed. The experimental results were compared against the values obtained from a theoretical model of the imaging system. Results: The average difference between theoretical and experimental w{sub t} was found to range from 8% to 21%. Experimental w{sub t} values increase with phantom thickness and Cu thickness, depend somewhat on Sn thickness, and vary more as a function of breast composition in thick breasts than in thin breasts. Theoretical and experimental mean and standard deviation in the per-pixel SI differ by -7% to 10% and by -3% to 4%. Theoretical and experimental SDNR values differ, on average, by 1.5%. Iodine concentrations can be predicted from SDNR; the relationship can be accurately fit to a quadratic. In the images of the structured phantom, iodine concentrations of 1 mg/cm{sup 2} and larger are discernable. Conclusions: The strong agreement between experimental and theoretical results in this article indicates that the authors' computer model is accurate.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗