Search NASA⌕ Search

SEARCH · Search NASA

Results for “Surface sampling probe”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,009 records · Page 56

A Herschel/HIFI legacy survey of HF and H{sub 2}O IN the galaxy: Probing diffuse molecular cloud chemistry

We combine Herschel observations for a total of 12 sources to construct the most uniform survey of HF and H{sub 2}O in our Galactic disk. Both molecules are detected in absorption along all sight lines. The high spectral resolution of the Heterodyne Instrument for the Far-infrared (HIFI) allows us to compare the HF and H{sub 2}O distributions in 47 diffuse cloud components sampling the disk. We find that the HF and H{sub 2}O velocity distributions follow each other almost perfectly and establish that HF and H{sub 2}O probe the same gas-phase volume. Our observations corroborate theoretical predictions that HF is a sensitive tracer of H{sub 2} in diffuse clouds, down to molecular fractions of only a few percent. Using HF to trace H{sub 2} in our sample, we find that the N(H{sub 2}O)-to-N(HF) ratio shows a narrow distribution with a median value of 1.51. Our results further suggest that H{sub 2}O might be used as a tracer of H{sub 2}—within a factor of 2.5—in the diffuse interstellar medium (ISM). We show that the measured factor of ∼2.5 variation around the median is driven by true local variations in the H{sub 2}O abundance relative to H{sub 2} throughout the disk. The latter variability allows us to test our theoretical understanding of the chemistry of oxygen-bearing molecules in the diffuse gas. We show that both gas-phase and grain-surface chemistry are required to reproduce our H{sub 2}O observations. This survey thus confirms that grain surface reactions can play a significant role in the chemistry occurring in the diffuse ISM (n{sub H} ⩽ 1000 cm{sup −3}).

79 ASTRONOMY AND ASTROPHYSICS↗

Wideband Single-Crystal Transducer for Bone Characterization

The microgravity conditions of space travel result in unique physiological demands on the human body. In particular, the absence of the continual mechanical stresses on the skeletal system that are present on Earth cause the bones to decalcify. Trabecular structure decreases in thickness and increases in spacing, resulting in decreased bone strength and increased risk of injury. Thus, monitoring bone health is a high priority for long-term space travel. A single probe covering all frequency bands of interest would be ideal for such measurements, and this would also minimize storage space and eliminate the complexity of integrating multiple probes. This invention is an ultrasound transducer for the structural characterization of bone. Such characterization measures features of reflected and transmitted ultrasound signals, and correlates these signals with bone structure metrics such as bone mineral density, trabecular spacing, and thickness, etc. The techniques used to determine these various metrics require measurements over a broad range of ultrasound frequencies, and therefore, complete characterization requires the use of several narrowband transducers. This is a single transducer capable of making these measurements in all the required frequency bands. The device achieves this capability through a unique combination of a broadband piezoelectric material; a design incorporating multiple resonator sizes with distinct, overlapping frequency spectra; and a micromachining process for producing the multiple-resonator pattern with common electrode surfaces between the resonators. This device consists of a pattern of resonator bars with common electrodes that is wrapped around a central mandrel such that the radiating faces of the resonators are coplanar and can be simultaneously applied to the sample to be measured. The device operates as both a source and receiver of acoustic energy. It is operated by connection to an electronic system capable of both providing an excitation signal to the transducer and amplifying the signal received from the transducer. The excitation signal may be either a wide-bandwidth signal to excite the transducer across its entire operational spectrum, or a narrow-bandwidth signal optimized for a particular measurement technique. The transducer face is applied to the skin covering the bone to be characterized, and may be operated in through-transmission mode using two transducers, or in pulse-echo mode. The transducer is a unique combination of material, design, and fabrication technique. It is based on single-crystal lead magnesium niobate lead titanate (PMN-PT) piezoelectric material. As compared to the commonly used piezoceramics, this piezocrystal has superior piezoelectric and elastic properties, which results in devices with superior bandwidth, source level, and power requirements. This design necessitates a single resonant frequency. However, by operating in a transverse length-extensional mode, with the electric field applied orthogonally to the extensional direction, resonators of different sizes can share common electrodes, resulting in a multiply-resonant structure. With carefully sized resonators, and the superior bandwidth of piezocrystal, the resonances can be made to overlap to form a smooth, wide-bandwidth characteristic.

Liang, Yu↗

Wideband Single-Crystal Transducer for Bone Characterization

The microgravity conditions of space travel result in unique physiological demands on the human body. In particular, the absence of the continual mechanical stresses on the skeletal system that are present on Earth cause the bones to decalcify. Trabecular structure decreases in thickness and increases in spacing, resulting in decreased bone strength and increased risk of injury. Thus, monitoring bone health is a high priority for long-term space travel. A single probe covering all frequency bands of interest would be ideal for such measurements, and this would also minimize storage space and eliminate the complexity of integrating multiple probes. This invention is an ultrasound transducer for the structural characterization of bone. Such characterization measures features of reflected and transmitted ultrasound signals, and correlates these signals with bone structure metrics such as bone mineral density, trabecular spacing, and thickness, etc. The techniques used to determine these various metrics require measurements over a broad range of ultrasound frequencies, and therefore, complete characterization requires the use of several narrowband transducers. This is a single transducer capable of making these measurements in all the required frequency bands. The device achieves this capability through a unique combination of a broadband piezoelectric material; a design incorporating multiple resonator sizes with distinct, overlapping frequency spectra; and a micromachining process for producing the multiple-resonator pattern with common electrode surfaces between the resonators. This device consists of a pattern of resonator bars with common electrodes that is wrapped around a central mandrel such that the radiating faces of the resonators are coplanar and can be simultaneously applied to the sample to be measured. The device operates as both a source and receiver of acoustic energy. It is operated by connection to an electronic system capable of both providing an excitation signal to the transducer and amplifying the signal received from the transducer. The excitation signal may be either a wide-bandwidth signal to excite the transducer across its entire operational spectrum, or a narrow-bandwidth signal optimized for a particular measurement technique. The transducer face is applied to the skin covering the bone to be characterized, and may be operated in through transmission mode using two transducers, or in pulse-echo mode.

Liang, Yu↗

A Summary of Large Raindrop Observations from GPM GV Field Campaigns

NASA's Global Precipitation Measurement Mission (GPM) has conducted as series of Ground Validation (GV) studies to assist algorithm development for the GPM core satellite. Characterizing the drop size distribution (DSD) for different types of precipitation systems is critical in order to accurately estimate precipitation across the majority of the planet. Thus far, GV efforts have sampled DSDs in a variety of precipitation systems from Finland to Oklahoma. This dataset consists of over 33 million raindrops sampled by GPM GV's two‐dimensional video disdrometers (2DVD) and includes RSD observations from the LPVEx, MC3E, GCPEx, HyMEx and IFloodS campaigns as well as from GV sites in Huntsville, AL and Wallops Island, VA. This study focuses on the larger end of the raindrop size spectrum, which greatly influences radar reflectivity and has implications for moment estimation. Thus knowledge of the maximum diameter is critical to GPM algorithm development. There are over 24,000 raindrops exceeding 5 mm in diameter contained within this disdrometer dataset. The largest raindrops in the 2DVD dataset (>7‐8 mm in diameter) are found within intense convective thunderstorms, and their origins are believed to be hailstones. In stratiform rainfall, large raindrops have also been found to fall from lower and thicker melting layers. The 2DVD dataset will be combined with that collected by dual‐polarimetric radar and aircraft particle imaging probes to "follow" the vertical evolution of the DSD tail (i.e., retrace the large drops from the surface to their origins aloft).

Gatlin, Patrick N.↗

Role of heat treatment and build orientation in the microstructure sensitive deformation characteristics of IN718 produced via SLM additive manufacturing

The benefits of additive manufacturing have been well documented, but prior to these materials being used in critical applications, the deformation mechanisms must be properly characterized. In this work, the role of heat treatment and build orientation of selective laser melting IN718 is investigated through detailed characterization. The microstructure of this material is probed through a combination of electron microscopy to identify the precipitate structure, electron backscatter diffraction to quantify the grain-level features, and synchrotron-based X-ray microcomputed tomography to detect porosity. A high degree of porosity is observed spatially near the free surface of the part, where the contour during the build process meets the interior hatch. Further, microstructure based deformation mechanisms are explored through digital image correlation relative to the grain features after monotonic and cyclic loading and in situ high-energy X-ray diffraction to identify the lattice strain evolution in these materials. Demarcations between the behaviors of the as-built versus post-processed materials are discussed; specifically, in terms of anisotropy with respect to build direction and values of the strength properties, based on the grain morphology, coherent twin formation, and precipitate structure. In conclusion, the presence of dislocation sub-structures within the grains is observed to homogenize deformation within the as-built sample, while strain partitioning is observed during loading of the post-processed sample.

36 MATERIALS SCIENCE↗

Concurrence of quantum anomalous Hall and topological Hall effects in magnetic topological insulator sandwich heterostructures

The quantum anomalous Hall (QAH) effect is a consequence of non-zero Berry curvature in momentum space. The QAH insulator harbours dissipation-free chiral edge states in the absence of an external magnetic field. Yet, the topological Hall (TH) effect, a hallmark of chiral spin textures, is a consequence of real-space Berry curvature. Herein, by inserting a topological insulator (TI) layer between two magnetic TI layers, we realized the concurrence of the TH effect and the QAH effect through electric-field gating. The TH effect is probed by bulk carriers, whereas the QAH effect is characterized by chiral edge states. The appearance of the TH effect in the QAH insulating regime is a consequence of chiral magnetic domain walls that result from the gate-induced Dzyaloshinskii–Moriya interaction and occurs during the magnetization reversal process in the magnetic TI sandwich samples. The coexistence of chiral edge states and chiral spin textures provides a platform for proof-of-concept dis- sipationless spin-textured spintronic applications.

36 MATERIALS SCIENCE↗

An assessment of spall failure modes in laser powder bed fusion fabricated stainless steel 316L with low-volume intentional porosity

Here, this paper reports on spall failure and damage modes in Laser Powder Bed Fusion fabricated Stainless Steel 316L (SS316L) with intentional levels of low-volume (1–5 vol. %) porosity and pore sizes of 200, 350, and 500 μm. The fabricated specimens were subjected to uniaxial-strain plate-impact loading at ~4.5 GPa, to initiate incipient spall failure. Analysis of velocimetry profiles measured using multi-probe photon-Doppler velocimetry coupled with post-mortem analysis of soft-recovered samples reveals local suppression of spall failure (termed as spall-dominated) as a function of porosity, as the failure mechanism transitions from spall-centered tensile stress dominated to a pore-centered microstructure-dominated damage mode involving void/crack nucleation and growth at pre-existing pores. The critical porosity level where the suppression of spall failure is first observed, as well as the spall location, is dependent on both the volume fraction and the size of the initially fabricated pores. In samples of 500 μm pore size, the suppression of spall failure is observed with as little as 1 vol. % porosity, while samples with smaller pores (200 μm) still experience spall-centered tensile stress dominated failure with higher levels (5 vol. %) of porosity. In the case of pore-centered microstructure-dominated failure, spall damage can occur but the spall plane is shifted toward the rear free surface, or more generally in areas further away from the region with pores. Highly heterogeneous deformation twinning, shear banding, grain rotation, and cracking are observed in the vicinity of pre-existing pores and expected spall failure sites.

36 MATERIALS SCIENCE↗

Ultrasensitive Label-free Electronic Chip for DNA Analysis Using Carbon Nanotube Nanoelectrode Arrays

There is a strong need for faster, cheaper, and simpler methods for nucleic acid analysis in today s clinical tests. Nanotechnologies can potentially provide solutions to these requirements by integrating nanomaterials with biofunctionalities. Dramatic improvement in the sensitivity and multiplexing can be achieved through the high-degree miniaturization. Here, we present our study in the development of an ultrasensitive label-free electronic chip for DNA/RNA analysis based on carbon nanotube nanoelectrode arrays. A reliable nanoelectrode array based on vertically aligned multi-walled carbon nanotubes (MWNTs) embedded in a SiO2 matrix is fabricated using a bottom-up approach. Characteristic nanoelectrode behavior is observed with a low-density MWNT nanoelectrode array in measuring both the bulk and surface immobilized redox species. The open-end of MWNTs are found to present similar properties as graphite edge-plane electrodes, with a wide potential window, flexible chemical functionalities, and good biocompatibility. A BRCA1 related oligonucleotide probe with 18 bases is covalently functionalized at the open ends of the MWNTs and specifically hybridized with an oligonucleotide target as well as a PCR amplicon. The guanine bases in the target molecules are employed as the signal moieties for the electrochemical measurements. Ru(bpy)3(2+) mediator is used to further amplify the guanine oxidation signal. This technique has been employed for direct electrochemical detection of label-free PCR amplicon through specific hybridization with the BRCAl probe. The detection limit is estimated to be less than approximately 1000 DNA molecules, approaching the limit of the sensitivity by laser-based fluorescence techniques in DNA microarray. This system provides a general electronic platform for rapid molecular diagnostics in applications requiring ultrahigh sensitivity, high-degree of miniaturization, simple sample preparation, and low- cost operation.

Li, Jun↗

Raman intensity as a probe of concentration near a crystal growing in solution

The feasibility of using Raman spectral scattering signals for measurements of concentration profiles near a crystal interface during growth or dissolution is discussed. With KH2PO4 (KDP) as a test material, optical multichannel analyzer (OMA) detection of a solute Raman vibrational band provided direct quantification of solute concentration with band intensity. The intersection of incident laser and Raman collection optics provided 3-D selective point measurements of the solution concentration field. Unlike many other techniques, the Raman band intensity is not sensitive to the typical temperature variations. Precision calibration of Raman intensity versus KDP concentration with less than 1 pct standard deviation error levels was demonstrated. A fiber optic, which sampled incident laser intensity and coupled it to the OMA, provided a fully synchronized monitor of fluctuations in laser power to correlate with observed Raman signals. With 1 W of laser power at the sample, good data statistics required eight repeated data collections at approximately 2.5 min collection. The accumulated time represents the concentration measurement time at one spatial location. Photomicroscopy documented a 30 micrometer diameter by 200 micrometer of laser Raman scattering region in the solution near the crystal surface. The laser beam was able to approach up to 25 micrometer from the crystal surface. However, a crystal surface reflected intensity contribution was weakly detectable. Nucleated microcrystals were seen in the crystal-growing solution. These microcrystals convect right up to the crystal surface and indicate no quiet diffusion region under normal gravity conditions. Translation of the solution cell with respect to the optics caused systematic intensity errors.

Wilkinson, R. Allen↗

Lanthanum induced lattice strain improves hydrogen sulfide capacities of copper oxide adsorbents

This work probes the effects of La on reactions involving CuO sorbents and H 2 S in gaseous streams. La-CuO sorbents with nominal La/Cu atomic ratios of 1:2 achieved higher capacities (27 and 36 g H 2 S per 100 g sorbent) compared to CuO sorbents (25 g H 2 S per 100 g sorbent). Here, comparison of the La-CuO sorbents using energy dispersive x-ray spectroscopy and La L 3 -edge XAS suggested that increased capacity resulted from more uniform dispersion of La within the CuO phase (3.3 wt.% vs. 1.0 wt.% La). X-Ray absorption near edge structure analysis suggested more electron-rich Cu species in La-CuO samples, while extended X-ray absorption fine structure modeling showed an increase in single-scattering path lengths for neighboring and near-neighbor atoms. These changes suggest that La induces strain in the Cu-O lattice, thereby increasing H 2 S capacity by reducing energy barriers associated with surface reactions between oxygen atoms and adsorbed H 2 S molecules.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Atmospheric-pressure solution-cathode glow discharge: A versatile ion source for atomic and molecular mass spectrometry

We report an atmospheric-pressure solution-cathode glow discharge (SCGD) has been evaluated as an ion source for atomic, molecular, and ambient desorption/ionization mass spectrometry. The SCGD consists of a direct-current plasma, supported in the ambient air in the absence of gas flows, and sustained upon the surface of a flowing liquid cathode. Analytes introduced in the flowing liquid, as an ambient gas, or as a solid held near the plasma are vaporized and ionized by interactions within or near the discharge. Introduction of acidic solutions containing metal salts produced bare elemental ions as well as H 2 O, OH - and NO 3 - adducts. Detection limits for these elemental species ranged from 0.1 to 4 ppb, working curves spanned more than 4 orders of linear dynamic range, and precision varied between 5 and 16% relative standard deviation. Small organic molecules were also efficiently ionized from solution, and both the intact molecular ion and fragments were observed in the resulting SCGD mass spectra. Fragmentation of molecular species was found to be tunable; high discharge currents led to harder ionization, while low discharge currents produced stronger molecular-ion signals. Ambient gases and solids, desorbed by the plasma from a glass probe, were also readily ionized by the SCGD. Indeed, strong analyte signals were obtained from solid samples placed at least 2 cm from the plasma. These findings indicate that the SCGD might be useful also for ambient desorption/ionization mass spectrometry. In conclusion, combined with earlier results that showed the SCGD is useful for ionization of labile biomolecules, the results here indicate that the SCGD is a highly versatile ion source capable of providing both elemental and molecular mass-spectral information.

74 ATOMIC AND MOLECULAR PHYSICS↗

Real-time interfacial electron dynamics revealed through temporal correlations in x-ray photoelectron spectroscopy

We present a novel technique to monitor dynamics in interfacial systems through temporal correlations in x-ray photoelectron spectroscopy (XPS) signals. To date, the vast majority of time-resolved x-ray spectroscopy techniques rely on pump–probe schemes, in which the sample is excited out of equilibrium by a pump pulse, and the subsequent dynamics are monitored by probe pulses arriving at a series of well-defined delays relative to the excitation. By definition, this approach is restricted to processes that can either directly or indirectly be initiated by light. It cannot access spontaneous dynamics or the microscopic fluctuations of ensembles in chemical or thermal equilibrium. Enabling this capability requires measurements to be performed in real (laboratory) time with high temporal resolution and, ultimately, without the need for a well-defined trigger event. The time-correlation XPS technique presented here is a first step toward this goal. The correlation-based technique is implemented by extending an existing optical-laser pump/multiple x-ray probe setup by the capability to record the kinetic energy and absolute time of arrival of every detected photoelectron. The method is benchmarked by monitoring energy-dependent, periodic signal modulations in a prototypical time-resolved XPS experiment on photoinduced surface-photovoltage dynamics in silicon, using both conventional pump–probe data acquisition, and the new technique based on laboratory time. The two measurements lead to the same result. The findings provide a critical milestone toward the overarching goal of studying equilibrium dynamics at surfaces and interfaces through time correlation-based XPS measurements.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

THE DISCOVERY OF SEVEN EXTREMELY LOW SURFACE BRIGHTNESS GALAXIES IN THE FIELD OF THE NEARBY SPIRAL GALAXY M101

Dwarf satellite galaxies are a key probe of dark matter and of galaxy formation on small scales and of the dark matter halo masses of their central galaxies. They have very low surface brightness, which makes it difficult to identify and study them outside of the Local Group. We used a low surface brightness-optimized telescope, the Dragonfly Telephoto Array, to search for dwarf galaxies in the field of the massive spiral galaxy M101. We identify seven large, low surface brightness objects in this field, with effective radii of 10-30 arcseconds and central surface brightnesses of μ {sub g} ∼ 25.5-27.5 mag arcsec{sup –2}. Given their large apparent sizes and low surface brightnesses, these objects would likely be missed by standard galaxy searches in deep fields. Assuming the galaxies are dwarf satellites of M101, their absolute magnitudes are in the range –11.6 ≲ M{sub V} ≲ –9.3 and their effective radii are 350 pc-1.3 kpc. Their radial surface brightness profiles are well fit by Sersic profiles with a very low Sersic index (n ∼ 0.3-0.7). The properties of the sample are similar to those of well-studied dwarf galaxies in the Local Group, such as Sextans I and Phoenix. Distance measurements are required to determine whether these galaxies are in fact associated with M101 or are in its foreground or background.

79 ASTRONOMY AND ASTROPHYSICS↗

3D Motion of DNA-Au Nanoconjugates in Graphene Liquid Cell Electron Microscopy

Liquid-phase transmission electron microscopy (TEM) can probe and visualize dynamic events with structural or functional details at the nanoscale in a liquid medium. Prior efforts have focused on the growth and transformation kinetics of hard material systems, relying on their stability under electron beam. Our recently developed graphene liquid cell technique pushed the spatial resolution of such imaging to the atomic scale but still focused on growth trajectories of metallic nanocrystals. Here, we adopt this technique to imaging three-dimensional (3D) dynamics of soft materials instead, double strand (dsDNA) connecting Au nanocrystals as one example, at nanometer resolution. We show first that a graphene liquid cell can seal an aqueous sample solution of a lower vapor pressure than previously investigated well against the high vacuum in TEM. Then, from quantitative analysis of real time nanocrystal trajectories, we show that the status and configuration of dsDNA dictate the motions of linked nanocrystals throughout the imaging time of minutes. This sustained connecting ability of dsDNA enables this unprecedented continuous imaging of its dynamics via TEM. Moreover, the inert graphene surface minimizes sample-substrate interaction and allows the whole nanostructure to rotate freely in the liquid environment; we thus develop and implement the reconstruction of 3D configuration and motions of the nanostructure from the series of 2D projected TEM images captured while it rotates. In addition to further proving the nanoconjugate structural stability, this reconstruction demonstrates 3D dynamic imaging by TEM beyond its conventional use in seeing a flattened and dry sample. Altogether, we foresee the new and exciting use of graphene liquid cell TEM in imaging 3D biomolecular transformations or interaction dynamics at nanometer resolution.

3D motion↗

Imaging of turbulent structures and tomographic reconstruction of TORPEX plasma emissivity

In the TORPEX [A. Fasoli et al., Phys. Plasmas 13, 055902 (2006)], a simple magnetized plasma device, low frequency electrostatic fluctuations associated with interchange waves, are routinely measured by means of extensive sets of Langmuir probes. To complement the electrostatic probe measurements of plasma turbulence and study of plasma structures smaller than the spatial resolution of probes array, a nonperturbative direct imaging system has been developed on TORPEX, including a fast framing Photron-APX-RS camera and an image intensifier unit. From the line-integrated camera images, we compute the poloidal emissivity profile of the plasma by applying a tomographic reconstruction technique using a pixel method and solving an overdetermined set of equations by singular value decomposition. This allows comparing statistical, spectral, and spatial properties of visible light radiation with electrostatic fluctuations. The shape and position of the time-averaged reconstructed plasma emissivity are observed to be similar to those of the ion saturation current profile. In the core plasma, excluding the electron cyclotron and upper hybrid resonant layers, the mean value of the plasma emissivity is observed to vary with (T{sub e}){sup {alpha}}(n{sub e}){sup {beta}}, in which {alpha}=0.25-0.7 and {beta}=0.8-1.4, in agreement with collisional radiative model. The tomographic reconstruction is applied to the fast camera movie acquired with 50 kframes/s rate and 2 {mu}s of exposure time to obtain the temporal evolutions of the emissivity fluctuations. Conditional average sampling is also applied to visualize and measure sizes of structures associated with the interchange mode. The {omega}-time and the two-dimensional k-space Fourier analysis of the reconstructed emissivity fluctuations show the same interchange mode that is detected in the {omega} and k spectra of the ion saturation current fluctuations measured by probes. Small scale turbulent plasma structures can be detected and tracked in the reconstructed emissivity movies with the spatial resolution down to 2 cm, well beyond the spatial resolution of the probe array.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Injection‐Induced Shear Slip and Permeability Enhancement in Granite Fractures

Abstract Shear stimulation, so‐called hydroshearing , is believed to reactivate critical or near‐critical preexisting fractures by pressurized fluid injection, causing them to slip and dilate for economic production from geothermal and unconventional petroleum reservoirs. However, little or no experiments have been conducted to directly probe the coupled hydromechanical responses and permeability evolution during fracture shearing. In this paper, we present the results of novel injection‐induced shear tests on cylindrical granite samples each containing a single tensile or saw cut fracture. The shear test on rough fractures demonstrates that retainable permeability enhancement can be achieved through dilatant shear slip. The characteristic stick‐slip behavior of the fracture during shearing is also observed. Fracture aperture controlled by effective normal stress dominates the fluid flow in stick state, while in slip state, the major contributor to production increase is the irreversible normal dilation caused by fracture shear slip. The experimental data show that depending on the fracture roughness, the fracture slip process includes two quasi‐static slip intervals with a slip velocity of ~10 −9 to ~10 −6 m/s and a dynamic slip interval with a slip velocity of ~10 −7 to ~10 −5 m/s. The fracture slip correlates well with the associated stress relaxation: a faster fracture slip induces a quicker stress relaxation, and vice versa. The influence of surface roughness on the hydromechanical responses during fracture shearing and the shear‐induced asperity degradation are also studied. The various experimental observations on rough and smooth fractures clearly indicate that the key component to shear stimulation is fracture self‐propping by asperities.

Ye, Zhi↗

Potential of Probing the Lunar Regolith using Rover-Mounted Ground Penetrating Radar: Moses Lake Dune Field Analog Study

Probing radars have been widely recognized by the science community to be an efficient tool to explore lunar subsurface providing a unique capability to address several scientific and operational issues. A wideband (200 to 1200 MHz) Ground Penetrating Radar (GPR) mounted on a surface rover can provide high vertical resolution and probing depth from few tens of centimeters to few tens of meters depending on the sounding frequency and the ground conductivity. This in term can provide a better understand regolith thickness, elemental iron concentration (including ilmenite), volatile presence, structural anomalies and fracturing. All those objectives are of important significance for understanding the local geology and potential sustainable resources for future landing sites in particular exploring the thickness, structural heterogeneity and potential volatiles presence in the lunar regolith. While the operation and data collection of GPR is a straightforward case for most terrestrial surveys, it is a challenging task for remote planetary study especially on robotic platforms due to the complexity of remote operation in rough terrains and the data collection constrains imposed by the mechanical motion of the rover and limitation in data transfer. Nevertheless, Rover mounted GPR can be of great support to perform systematic subsurface surveys for a given landing site as it can provide scientific and operational support in exploring subsurface resources and sample collections which can increase the efficiency of the EVA activities for potential human crews as part of the NASA Constellation Program. In this study we attempt to explore the operational challenges and their impact on the EVA scientific return for operating a rover mounted GPR in support of potential human activity on the moon. In this first field study, we mainly focused on the ability of GPR to support subsurface sample collection and explore shallow subsurface volatiles.

Horz, F.↗

Debris Disk Structure and Morphology as Revealed by Aggressive STIS Multi-Roll Coronagraphy: A New Look at Some Old Friends

We present new imaging results from a well-selected sample of II circumstellar debris disks, all with HST pedigree, using STIS visible-light 6-roll PSF-template subtracted coronagraphy (PSFTSC). These new observations, pushing HST to its highest levels of coronagraphic performance, simultaneously probe both the interior regions of these debris systems, with inner working distances < app 8 AU for half the stars in this sample (corresponding to the giant planet and Kuiper belt regions within our own solar system), and the exterior regions far beyond. These new images enable direct inter-comparison of the architectures of these exoplanetary debris systems in the context of our own Solar System: These observations also permit us, for the first time, to characterize material in these regions at high spatial resolution and identify disk sub-structures that are signposts of planet formation and evolution; in particular, asymmetries and non-uniform debris structures that signal the presence of co-orbiting perturbing planets, and dynamical interactions (e.g., resulting in posited small grain stripping and disk "pollution") with the ISM. We focus here on recently acquired and reduced images of he circumstellar debris systems about: AU Mic (edge-on, and @ 10 pc the closest star in our sample), HD 61005, HD 32297 and HD 15115 (all with morphologies strongly suggestive of ISM wind interactions), HD 181327 & HDI07146 (close to face-on with respectively narrow and broad debris rings), and MP Mus (a "mature" proto-planetary disk hosted by a cTTS). All of our objects were previously observed in the near-IR with inferior spatial resolution and imaging efficacy, but with NICMOS r = 0.3" inner working angle (IWA) comparable to STIS multi-roll coronagraphy. The combination of new optical and existing near-IR imaging can strongly constrain the dust properties, thus enabling an assessment of grain processing and planetesimal populations. These results will directly inform upon the posited planet formation mechanisms that occur after the approximately 10 My epoch of gas depletion, a time in our solar system when giant planets were migrating and terrestrial planets were forming, and directly test theoretical models of these processes. These observations lmiquely probe both into the interior regions of these systems and are sensitive to and spatially resolve low surface-brightness (SB) material at large stellocentric distances with spatial resolution comparable to ACS and with augmenting NICMOS near-IR disk photometry in hand.

Grady, Carol A↗